Datalogic Rhino 10 Manuale utente

Categoria
Computer portatili palmari
Tipo
Manuale utente
Rhino
TM
10
User Manual
Datalogic Mobile S.r.l.
Via S. Vitalino 13
40012 - Lippo di Calderara di Reno
Bologna - Italy
Rhino™10 User's Manual
Software Version: 1.0.x
Part Number: 822001160
Ed.: 12/2011
Datalogic Mobile, Inc.
Eugene, OR 97402
U.S.A.
http://www.mobile.datalogic.com
© 2011 Datalogic Mobile, Inc. • All rights reserved. • Protected to the fullest extent under U.S. and international laws. •
Copying or altering of this document is prohibited without express written consent from Datalogic Mobile, Inc.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries including the U.S.A.
and the E.U. • Rhino is a trademark of Datalogic Mobile S.r.l.
Other brands and product names may be trademarks of their respective owners. • Reasonable measures were taken
to ensure that the information provided is complete and accurate at the time of publication. • Datalogic Mobile, Inc. is
not responsible for errors of omission or inaccuracies, as material becomes dated shortly following publication. How-
ever, Datalogic reserves the right to change any product specification at any time without prior notice. The information
contained herein is provided solely for the purpose of allowing customers to install, operate, configure, and develop ap-
plications for Datalogic manufactured equipment and is not to be released, reproduced, or used for any other purpose
without written permission of Datalogic Mobile, Inc.
The Bluetooth
®
word mark and logos are owned by Bluetooth SIG, Inc. and any use of such marks by Datalogic Mobile,
Inc. is under license.
Wi-Fi is a registered certification mark of the Wi-Fi Alliance.
Microsoft, WindowsCE, and the WindowsCE logo are registered trademarks of Microsoft Corporation in the United
States and/or other countries.
Contents
Safety Information.......................................................................................................................................................1
Service and Support ...................................................................................................................................................1
Web Support...........................................................................................................................................................1
Related Documents................................................................................................................................................1
Telephone Support.................................................................................................................................................1
The Rhino™ 10 Vehicle Computer.............................................................................................................................2
Product Overview ...................................................................................................................................................2
Optional Features...................................................................................................................................................2
Keypad....................................................................................................................................................................3
Using the Touch-Screen.........................................................................................................................................5
Using the Rhino™ 10 in Cold Environments..........................................................................................................6
Accessories ............................................................................................................................................................6
Increasing Memory Storage .................................................................................................................................12
Understanding WindowsCE......................................................................................................................................12
Finding Information on WindowsCE.....................................................................................................................12
Learning the Basic Skills ......................................................................................................................................12
Communicating with Rhino™ 10..........................................................................................................................15
Customizing the Rhino™ 10.................................................................................................................................18
Launching an Application Automatically...............................................................................................................21
Troubleshooting and Maintaining the Rhino.............................................................................................................25
Troubleshooting the Rhino ...................................................................................................................................26
Upgrading the Rhino™ 10 Software.....................................................................................................................27
Cleaning the Screen.............................................................................................................................................29
Accessories for the Rhino.....................................................................................................................................29
Appendix A – Specifications .....................................................................................................................................34
< page intentionally left blank>
Rhino™ 10 User Manual
Safety Information
Your safety is extremely important. Read and follow all warnings and cautions in this document before installing, han-
dling, and operating Datalogic equipment. You can be seriously injured, and equipment and data can be damaged if
you do not follow the safety warnings and cautions.
Warning: Warnings alert you to procedures that involve some amount of personal risk and may require spe-
cial training or tools.
Cau
tion: A caution alerts you to an operating procedure, practice, condition, or statement that must be
strictly observed to prevent equipment damage or destruction, or corruption or loss of data.
ESD Sensiti
ve: The operation requires an ESD safe working area and procedures to prevent equipment
damage and possible voiding of warranty.
et of circumstances.
Not
e: Notes either provide extra information about a topic or contain special instructions for handling a par-
ticular condition or s
Service and Support
Web Support
Visit the Datalogic web site at http://www.Datalogic.com and select Datalogic Mobile at the top of the page. Then, se-
lect Support & Services for all your support needs including submitting a support request, access to software updates,
and links to download our current manuals.
Related Documents
The Datalogic web site also contains our documents that you can download for free.
To download documents
1. Visit http://www.mobile.datalogic.com
.
2. Select Support & Services.
3. Select Manuals.
4. Choose the Product documentation you want to download.
Telephone Support
For telephone support, select Contact Us on the Datalogic Mobile web page and select your country.
Before you call Datalogic Product Support, make sure you have the following information ready:
Operating system version, displayed on main screen.
Serial number from label on back of unit
If you are using terminal emulation (TE), know the version and protocol. If you are not using TE, know the
language your custom application was written in and the tools you used to create it.
1
User Manual Rhino™ 10
2
The Rhino™ 10 Vehicle Computer
The Datalogic Rhino™ 10 is a rugged Vehicle Computer designed for real-time data collection applications in ware-
housing, distribution, work-in-process, time and attendance, and stationary applications.
Use this chapter to familiarize yourself with the Rhino™ 10 Vehicle Computer.
Product Overview
The Rhino™ 10 includes these standard features:
520 MHz Intel XScale PXA270 processor
128 MB Flash memory
128 MB RAM
Two USB host ports
Two serial ports
Summit 802.11 b/g radio (CF10G)
Secure Digital High Capacity (SDHC) socket for memory expansion up to 32 GB
Optional Features
We also offer other Rhino™ 10 models that include additional features such as:
Ethernet port (extended temperature version only)
Extended temperature operation range (-30°C to 60°C)
Rhino™ 10 User Manual
Keypad
The Rhino™ 10 has a 3 button Keypad on the lower front of the unit, Down, Up and Power. A LED on the keypad indi-
cates the power state of the Rhino.
Down Up Power
Using the Power Button
Press the Power ( ) button for 5 seconds to put the Rhino™ 10 into Suspend mode. In Suspend mode, the Rhino™
10 continues to supply power to all memory, but turns off power to most hardware. When you press the Power button
to turn the Rhino™ 10 back on, the computer resumes where it was when you turned it off.
Power Consumption (Typical):
Input Voltage On
(no peripherals)
Suspend
(no peripherals)
12 V 0.7A 230 mA
24 V 0.38 A 180 mA
36 V 0.25 A 70 mA
48 V 0.2 A 50 mA
When a Rhino™ 10 is suspended and resumes, the 802.11 connection requires re-authentication. This can take any-
where from 3 seconds to several minutes depending on your system’s re-authentication requirements.
Status LED
The Rhino™ 10 uses three brightness levels on the green status LED to indicate the status of power and operation.
LED State Status
OFF Not connected to a power source or the power source is off.
Dim Connected to a live power source, unit is in the suspend state.
Blinking Unit running
Bright Unit Booting
3
User Manual Rhino™ 10
Adjusting the Screen Brightness
To adjust the screen brightness:
Press UP button to increases the brightness.
Press Down button to decreases the brightness.
You can also adjust the brightness settings by going to Start > Settings > Control Panel > Backlight. Move the track
bar pointer to the brightness level desired.
Adjusting the Volume
To adjust the volume
Press and hold the Power button then press the UP button to increases the volume. The computer will play
the Default Sound at the new volume setting.
Press and hold the Power button then press the Down button to decreases the volume. The computer will
play the Default Sound at the new volume setting.
You can also adjust the volume settings by going to Start > Settings > Control Panel > Volume & Sounds.
4
Rhino™ 10 User Manual
Using the Touch-Screen
The Rhino™ 10 has a 10.4 inch color VGA display with a resolution of 640 x 480 pixels with a touch-screen. The de-
fault display that appears when you turn on the Rhino™ 10 is the Windows Embedded CE 6.0 standard screen. This
screen appears unless you have an application installed to automatically run on the Rhino™ 10.
Navigating the Touch-Screen
You can use the stylus accessory or a finger to navigate the touch screen. If using your finger, it is best to use the tap
and hold technique, particularly on small items such as command or toolbars in an application.
Action Description
Tap Touch the screen once with the stylus or finger to select options, open or close appli-
cations, or launch menus.
Drag Hold the stylus or your finger on the screen and drag across the screen to select text
and images.
Tap and hold Tap and hold the stylus or your finger on an item to see a menu of actions available
for that item. On the pop-up menu that appears, tap the action you want to perform.
Calibrate the Touch-Screen
1. Tap Start > Settings > Control Panel > Stylus > Calibrate Tab.
2. Tap Calibrate and follow the instructions to align the screen. Note that alignment input occurs when you lift
the stylus from each location. When complete, simply tap the screen to return to the Touch panel control
panel.
If the touch-scre
en is so out of alignment that you cannot open the Start menu, you may need to use a
pointing device such as a USB mouse to select the Calibrate control.
5
User Manual Rhino™ 10
6
Resetting the Rhino™ 10
There are several reset methods for the Rhino™ 10.
A warm boot
terminates an unresponsive application and clears the working RAM, but preserves the RAM and flash file
systems. Registry is restored from persistent memory if available or returned to factory default.
A cold boot
forces all applications to close, completely reinitializing the system. It clears the working RAM and RAM file
system, but the flash file system is preserved. Registry is restored from persistent memory if available or returned to
factory default.
A clean boot
restores the Rhino™ 10 to a clean configuration: the registry, RAM and flash file systems return to a clean
status that conforms to factory default.
Warm Boot
To perform a warm boot, go to the \Windows directory and run the Reboot command. Alternatively, if necessary you
can remove the upper left panel by removing the 4 screws and reboot by pressing the push button under the cover.
Cold Boot
To perform a cold boot, go to the \Windows directory and run the Cold Reboot command.
Clean Boot
To perform a clean boot, do the following steps:
1. Perform a Warm or Cold boot as above.
2. Press and hold down the up and down keys simultaneously on the front of the terminal until the terminal dis-
plays the touch calibration screen.
Using the Rhino™ 10 in Cold Environments
If you are going to use the Rhino™ 10 in extreme cold conditions below 0°C (32°F) for an extended period of time
(more than 20 minutes), you should turn on the power at room temperature for at least 5 minutes prior to using it in the
cold environment. This process of “warming up” the Rhino™ 10 helps preserve the lighting on the display and the flexi-
bility of the touch-screen and keypad. We also recommend the use of the low temperature Rhino™ 10 model for these
environments.
Accessories
Using an External Keyboard
You can use many standard USB compatible keyboards. Datalogic recommends the use of a sealed/ruggedized key-
board:
Sealed/rugged keyboards are available from Datalogic including: full sized QWERTY, ABCD, or mini
QWERTY USB keyboards
The keyboard attaches to one of the two USB ports on the Rhino. It is automatically detected and prepared
for use.
For information on installing the rugged keyboard and its mount, see the Rhino™ 10 Installation manual.
Using a Barcode Scanner
Your can use either a USB or serial scanner with the Rhino™10 computer. Be sure to order your scanner with the ap-
propriate cable.
Rhino™ 10 User Manual
Connecting a USB Scanner
1. Loosen the screws on the USB retainer and move the retainer away from the USB connector.
2. Plug the cable into one of the USB ports. Depending on the scanner you are attaching, you may hear a series
of beeps and the Good Read light may flash.
3. Slide the USB retainer toward the connector until it is firmly against the USB connector. Tighten the two
screws.
4. The USB port will recognize the scanner as a type of Human Input Device (HID) and configure it automati-
cally to function as a keyboard input. Any application that accepts keyboard input will receive the output
from the USB scanner. There is now visual indication that the USB scanner is operational.
5. To test, simply open an application that accepts keyboard input, such as WordPad and scan a label to see
the data on the screen.
Connecting a Serial Scanner
The serial ports can supply either 5V or 12V power on pin 9 of the connector. The factory default is 5V on both
COM1 and COM2. Verify which voltage the scanner requires. If you need to change the voltage, see the Installa-
tion Manual for directions. If necessary, attach the cable to the tethered scanner.
1. Attach the scanner’s RS-232 cable to the appropriate COM connector on the Rhino. Depending on the scan-
ner you are attaching, you may hear a series of beeps and the Good Read light may flash. Tighten the
screws to make sure the cable stays attached during use.
2. To receive data from the scanner, two approaches can be used.
3. Custom application software can manage the serial port, configured it and accept data under control of the
application.
4. The included ScanWedge application can be used to configure the serial port and convert the serial received
data to keyboard characters that can then be used by any application that accepts keyboard input.
Using ScanWedge
ScanWedge allows the Rhino to receive serial and/or Bluetooth data from devices such as Barcode
Scanners or RFID readers via the serial ports or a USB Dongle. Received data is pushed into the key-
board buffer so that it is available to applications. You can start ScanWedge in two ways.
1.
Double Tap MyDevice->Windows, and then double tap on the ScanWedge Icon.
2. Select Start->Programs->ScanWedge. The first time after a clean boot, both serial ports and Bluetooth are
disabled. To enable a port, tap on the system tray icon. This will open the configuration dialog box.
7
User Manual Rhino™ 10
3. Select the tab for the port you want to use. Set the parameters to match the device you are connecting.
Termination characters are stripped from the data sent by the scanner and new termination characters are added as
defined in the checkboxes. These settings are common for all ports.
You can check the configuration by sending data from your device (scan a label). If the data is received with no errors
it is shown in the Test Data text box. If there were errors when receiving the data, the error will be shown next to the
Baud Rate drop down for the Serial Ports and below the Devices list box for Bluetooth. Framing errors usually indicate
an incorrect baud rate setting.
4. Once you have successfully configured the ports click Save to save your setup parameters. At this point the
dialog will be closed and a white icon will be in the system tray.
If you want to change the configuration, simply tap on the system tray icon to open the configuration dialog box.
If you want to disable ScanWedge, select “Disable” in the baud rate dropdown in both COM tabs, uncheck “Enabled
on the Bluetooth tab and SAVE. A confirmation dialog will ask if you really want to disable ScanWedge. ScanWedge
will not restart on the next boot, but remain disabled.
8
Rhino™ 10 User Manual
If you want to tempora
rily disable ScanWedge, click Exit. A confirmation dialog will ask if you really want to disable
ScanWedge. The next time you start ScanWedge it will restore the ports as you configured them. ScanWedge will al-
so resume on the next boot.
Verify that your scanner is working by opening any application that accepts keyboard data, such as WordPad, then
scan a barcode label and the data will appear in the application.
Bluetooth
1. Select the Bluetooth Tab. On the first entry, the Enabled checkbox will be unchecked.
2. Select Enabled. ScanWedge will attempt to initialize the radio. Any problems will be displayed on the status
line.
3. Plug in your Bluetooth dongle, tap Enable and the Scan button will become active. Bluetooth Devices require
discovery to be recognized by the Rhino™ 10. Your scanner manual will have instructions on how to start a
discovery process.
9
User Manual Rhino™ 10
4. Once the scanner is in discovery mode, simply tap “Scan” on the Bluetooth tab. After a few seconds a list of
all available Bluetooth device names will be displayed in the Devices list box.
5. Select the device you want to pair with the Rhino™ 10 and tap “Pair”. If the scanner has security enabled an
Authentication Request dialog will appear. You can use an attached keyboard or use the SIP to enter the
PIN.
10
Rhino™ 10 User Manual
6. Once the scanner is paired, you can test it by scanning a label and examining the Test Data box.
At this point, you should save the configuration. Once the pairing has been saved ScanWedge will attempt to re-pair
with the scanner on each power up or whenever ScanWedge is restarted. When the dialog appears simply tap Scan to
re-pair with the scanner.
11
User Manual Rhino™ 10
12
Increasing Memory Storage
You can use an SD card to increase file storage and install software. The Rhino™ 10 currently supports SD and SDHC
cards that hold up to 32 GB of information. The SD card slot is located on the top of the Rhino™ 10 under the left top
cover. See the Installation manual on how to install a SD memory card.
Once installed, the SD Memory card is treated by WinCE as a Hard Disk called StorageCard. You (or your application)
can use the SD Memory as you would any Hard Disk or USB flash drive.
Understanding WindowsCE
This chapter introduces Microsoft WindowsCE. WindowsCE and many other software features on the Rhino™ 10
come directly from Microsoft or other third parties. While Datalogic makes every effort to evaluate these technologies,
Datalogic makes no guarantees about the suitability of the software for any specific use.
Use the command bar at the bottom of the screen to perform tasks in programs. The command bar includes menus,
icons, and the onscreen keyboard. While using your Rhino, keep these key points in mind:
Tap Start on the navigation bar, located at the bottom left of the screen, to quickly move to programs, files,
and settings.
Tap and hold an item to see a pop-up menu containing a list of actions you can perform. Pop-up menus give
you quick and easy access to the most common actions.
Finding Information on WindowsCE
Use these Links for additional information about Microsoft WindowsCE:
msdn.microsoft.com/support/
support.microsoft.com/
news.microsoft.com
Learning the Basic Skills
This section describes the basic concepts of using and customizing your Rhino™ 10 Computer.
Using the Default Screen
When you turn on your Rhino™ 10 for the first time each day, you see the Default screen.
Status icons display information such as when the Rhino™ 10 is connected to the network, to the Internet, or has a
scanner attached. You can tap an icon to open the associated setting or program.
Accessing Programs
You can switch from one program to another by selecting it from the Start menu. (You can customize which programs
you see on this menu. See the configuration section.)
To access programs
Tap Start > Programs and then the program name.
Rhino™ 10 User Manual
The following is a partial list of programs that are on your Rhino™ 10, in the order they appear in the Start menu.
Programs->Device Tools->Wavelink Avalanche
Programs->Summit->SCU
Command Prompt
Internet Explorer
Task Manager
Windows Explorer
Favorites
Documents
Settings -> Control Panel
Network and Dial-UP Connections
Taskbar and Start Menu
Help
Run
Entering Information
You can enter information on your Rhino™ 10 in several ways depending on the program you are using:
Software Input Panel
External Keyboard
Software Keyboard (optional)
Barcode Scanner
Software Keyboard or External Keyboard
Use the Software Input Panel or an external keyboard to enter information in any program on your Rhino™ 10 Com-
puter. In either
case, the characters appear as typed text on the screen.
Software Keyboards
The Rhino™ 10 comes with 4 Software Keyboards, also called Software Input Panels (SIP), allowing
you to input data using an on-screen keypad. To select a SIP, click the icon in the lower right corner of
the screen in the system tray. This may be a keyboard or a pen icon. This will display the list of four
software keyboards. Clicking on the desired keyboard will cause it to display on the screen.
13
User Manual Rhino™ 10
The Keyboard and Large Keyboard selections are standard Microsoft keyboards, and work just as a standard key-
board. The small input panel works best with a stylus while the Large Keyboard works best with a finger.
The Numeric Keypad takes up less space on the screen, and allows inputting numeric data.
Clicking SHIFT on the Numeric Keypad will shift the SIP into function key mode allowing the user to input F1-F12.
14
Rhino™ 10 User Manual
Vertical Keyp
ad provides the same functionality as the Numeric Keypad, but in a vertical orientation.
Typing With the Onscreen Keyboard
On the soft keyboard that is displayed, tap the keys with your stylus or finger.
To type lowercase letters, tap the keys.
To type a single uppercase letter or symbol, tap the Shift key.
To type multiple uppercase letters or symbols, tap the CAP key.
Selecting Typed Text
If you want to edit or format typed text, you must select it first. Drag the stylus across the text you want to select. You
can cut, copy, and paste text by tapping and holding the selected words and then tapping an editing command on the
pop-up menu or by tapping the command under Menu.
Communicating with Rhino™ 10
Rhino™ 10 has three communications options, Activesync, Ethernet and 802.11 radio. Each option is described below.
15
ctivesync Using A
NOTE: Activesync works only through the serial connection since both USB ports are configured for
host only communications.
The Wi
ndows CE image provided for the Rhino™ 10 includes facilities necessary to establish a connection with a host
computer using ActiveSync. To do this, ActiveSync should be installed on the host computer. It may be downloaded
from Microsoft's website: (http://www.microsoft.com/windowsmobile/
activesync/activesync45.mspx)
Cable
A standard null modem cable is required (can use Datalogic P/N 94A051020). This cable should have the following pi-
nout:
DB9 Male DB9 Male
1 & 4 6
2 3
3 2
5 5
6 1 & 4
7 8
8 7
Do not connect pin 9.
In order to establish a connection between the target (Rhino™ 10) and the host (ActiveSync) manually, the following
steps are required:
On Host (workstation)
1. Make sure no other applications are using the COM1 port.
User Manual Rhino™ 10
2.
Connect the null modem cable on COM1 of the Host.
3. Configure ActiveSync to use COM1. The following settings should be applied in the ActiveSync Connection
Settings dialog box:
On Rhino™ 10
1. Make sure no other application is using the COM1 port. In particular, check if ScanWedge is running and if
so, open the dialog and Exit.
2. Navigate to \Windows and locate ActiveSyncLauncher.
3. Connect the serial cable to Com1 (the right most DB9)
4. Double tap ActiveSyncLauncher. A dialog box will appear, and show the status of the connection process.
16
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Datalogic Rhino 10 Manuale utente

Categoria
Computer portatili palmari
Tipo
Manuale utente

in altre lingue