Yamaha SWP2 Manuale del proprietario

Categoria
Apparecchiature musicali supplementari
Tipo
Manuale del proprietario
EnglishDeutschFrançaisEspañolPortuguêsItalianoРусский
Owners Manual
Bedienungsanleitung
Mode d’emploi
Manual de instrucciones
Manual do Proprietário
Manuale di istruzioni
Руководство пользователя
JA
RU
IT
PT
ES
FR
DE
EN
L
2
SWITCH
SWP2
-
10MMF
SWP2
-
10SMF
SWP2 Owner’s Manual
2
Explanation of Graphical Symbols
Explication des symboles
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous
voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
L’éclair avec une flèche à l’intérieur d’un triangle équilatéral est destiné à attirer l’attention de l’utilisateur sur la présence d’une « tension
dangereuse » non isolée à l’intérieur de l’appareil, pouvant être suffisamment élevée pour constituer un risque d’électrocution.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance
(servicing) instructions in the literature accompanying the product.
Le point d’exclamation à l’intérieur d’un triangle équilatéral est destiné à attirer l’attention de l’utilisateur sur la présence d’instructions
importantes sur l’emploi ou la maintenance (réparation) de l’appareil dans la documentation fournie.
IMPORTANT SAFETY INSTRUCTIONS
1 Read these instructions.
2 Keep these instructions.
3 Heed all warnings.
4 Follow all instructions.
5 Do not use this apparatus near water.
6 Clean only with dry cloth.
7 Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
8 Do not install near any heat sources such as radiators, heat registers,
stoves, or other apparatus (including amplifiers) that produce heat.
9 Do not defeat the safety purpose of the polarized or grounding-type
plug. A polarized plug has two blades with one wider than the other.
A grounding type plug has two blades and a third grounding prong.
The wide blade or the third prong are provided for your safety. If the
provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
10 Protect the power cord from being walked on or pinched particularly
at plugs, convenience receptacles, and the point where they exit from
the apparatus.
11 Only use attachments/accessories specified by the manufacturer.
12 Use only with the cart, stand, tripod, bracket, or table
specified by the manufacturer, or sold with the
apparatus. When a cart is used, use caution when
moving the cart/apparatus combination to avoid
injury from tip-over.
13 Unplug this apparatus during lightning storms or
when unused for long periods of time.
14 Refer all servicing to qualified service personnel. Servicing is
required when the apparatus has been damaged in any way, such as
power-supply cord or plug is damaged, liquid has been spilled or
objects have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normally, or has been
dropped.
PRÉCAUTIONS CONCERNANT LA
SÉCURITÉ
1 Lire ces instructions.
2 Conserver ces instructions.
3 Tenir compte de tous les avertissements.
4 Suivre toutes les instructions.
5 Ne pas utiliser ce produit à proximité d’eau.
6 Nettoyer uniquement avec un chiffon propre et sec.
7 Ne pas bloquer les orifices de ventilation. Installer l’appareil
conformément aux instructions du fabricant.
8 Ne pas installer l’appareil à proximité d’une source de chaleur comme
un radiateur, une bouche de chaleur, un poêle ou tout autre appareil
(y compris un amplificateur) produisant de la chaleur.
9 Ne pas modifier le système de sécurité de la fiche polarisée ou de la
fiche de terre. Une fiche polarisée dispose de deux broches dont une
est plus large que l’autre. Une fiche de terre dispose de deux broches
et d’une troisième pour le raccordement à la terre. Cette broche plus
large ou cette troisième broche est destinée à assurer la sécurité de
l’utilisateur. Si la fiche équipant l’appareil n’est pas compatible avec
les prises de courant disponibles, faire remplacer les prises par un
électricien.
10 Acheminer les cordons d’alimentation de sorte qu’ils ne soient pas
piétinés ni coincés, en faisant tout spécialement attention aux fiches,
prises de courant et au point de sortie de l’appareil.
11 Utiliser exclusivement les fixations et accessoires spécifiés par le
fabricant.
12 Utiliser exclusivement le chariot, le stand, le trépied,
le support ou la table recommandés par le fabricant
ou vendus avec cet appareil. Si l’appareil est posé
sur un chariot, déplacer le chariot avec précaution
pour éviter tout risque de chute et de blessure.
13 Débrancher l’appareil en cas d’orage ou lorsqu’il
doit rester hors service pendant une période
prolongée.
14 Confier toute réparation à un personnel qualifié. Faire réparer
l’appareil s’il a subi tout dommage, par exemple si la fiche ou le
cordon d’alimentation est endommagé, si du liquide a coulé ou des
objets sont tombés à l’intérieur de l’appareil, si l’appareil a été exposé
à la pluie ou à de l’humidité, si l’appareil ne fonctionne pas
normalement ou est tombé.
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
ATTENTION :
POUR RÉDUIRE LES RISQUES D'ÉLECTROCUTION, NE PAS RETIRER
LE CAPOT (OU LE DOS). NE CONTIENT PAS DE PIÈCES NÉCESSITANT
L'INTERVENTION DE L'UTILISATEUR. POUR TOUTE INTERVENTION,
FAIRE APPEL À DES PROFESSIONNELS QUALIFIÉS.
ATTENTION
RISQUE DE CHOC
ELECTRIQUE-NE PAS OUVRIR
The above warning is located on the top of the unit.
L’avertissement ci-dessus est situé sur le dessus de l’unité.
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.
AVERTISSEMENT
POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE
ÉLECTRIQUE, N’EXPOSEZ PAS CET APPAREIL À LA PLUIE OU À
L’HUMIDITÉ.
SWP2 Owner’s Manual
3
1. IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT!
This product, when installed as indicated in the instructions
contained in this manual, meets FCC requirements. Modifica-
tions not expressly approved by Yamaha may void your
authority, granted by the FCC, to use the product.
2. IMPORTANT: When connecting this product to accessories
and/or another product use only high quality shielded cables.
Cable/s supplied with this product MUST be used. Follow all
installation instructions. Failure to follow instructions could
void your FCC authorization to use this product in the USA.
3. NOTE: This product has been tested and found to comply
with the requirements listed in FCC Regulations, Part 15 for
Class “A” digital devices. Compliance with these require-
ments provides a reasonable level of assurance that your use
of this product, in a commercial environment, will not result in
harmful interference with other electronic devices. However,
operation of this product in a residential area is likely to cause
interference in some form. In this case you, the user, bear the
responsibility of correcting this condition.
This product generates/uses radio frequencies and, if not
installed and used according to the instructions found in the
users manual, may cause interference harmful to the opera-
tion of other electronic devices. Compliance with FCC regula-
tions does not guarantee that interference will not occur in all
installations. If this product is found to be the source of inter-
ference, which can be determined by turning the product
“OFF” and “ON”, please try to eliminate the problem by using
one of the following measures:
Relocate either the product generating the interference or the
device that is being affected by the interference.
Utilize power outlets that are on different branch (circuit
breaker or fuse) circuits or install AC line filter/s.
In the case of radio or TV interference, relocate/reorient the
antenna. If the antenna lead-in is 300 ohm ribbon lead,
change the lead-in to co-axial type cable.
If these corrective measures do not produce satisfactory
results, please contact the local retailer that is authorized to
distribute this type of product. If you can not locate the appro-
priate retailer, please contact Yamaha Corporation of Amer-
ica, Electronic Service Division, 6600 Orangethorpe Ave,
Buena Park, CA90620
The above statements apply ONLY to those products distrib-
uted by Yamaha Corporation of America or its subsidiaries.
(class A)
FCC INFORMATION (U.S.A.)
COMPLIANCE INFORMATION STATEMENT
(Supplierʼs declaration of conformity procedure)
Responsible Party: Yamaha Corporation of America
Address: 6600 Orangethorpe Ave. Buena Park CA 90620
Telephone: 714-522-9011
Type of Equipment: L2 Switch
Model Name: SWP2-10MMF, SWP2-10SMF
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1) this device may not cause harmful interference, and
2) this device must accept any interference received including interference
that may cause undesired operation.
SWP2 Owner’s Manual
4
PRECAUTIONS
PLEASE READ CAREFULLY
BEFORE PROCEEDING
Please keep this manual in a safe place for
future reference.
This product is designed for audio network. Do not use
for any purposes other than the one intended. Those
who are unfamiliar with handling or those who can not
handle according to this manual such as children,
should be supervised by responsible persons to
ensure safety.
WARNING
Always follow the basic precautions listed below to avoid
the possibility of serious injury or even death from
electrical shock, short-circuiting, damages, fire or other
hazards. These precautions include, but are not limited
to, the following:
If you notice any abnormality
If any of the following problems occur, immediately turn off the
power switch and disconnect the electric plug from the outlet.
- The power cord or plug becomes frayed or damaged.
- Unusual smells or smoke are emitted.
- Some object, or water has been dropped into the product.
- Cracks or other visible damage appear on the product.
Then have the product inspected or repaired by qualified
Yamaha service personnel.
Power supply/Power cord
Do not place the power cord near heat sources such as
heaters or radiators, and do not excessively bend or otherwise
damage the cord, place heavy objects on it, or place it in a
position where anyone could walk on, trip over, or roll anything
over it.
Only use the voltage specified as correct for the product. The
required voltage is printed on the name plate of the product.
Use only the supplied power cord/plug.
If you intend to use the product in an area other than in the
one you purchased, the included power cord may not be
compatible. Please check with your Yamaha dealer.
Check the electric plug periodically and remove any dirt or
dust which may have accumulated on it.
Make sure to fully insert the electric plug to prevent electric
shocks or fire.
This product receives power from multi sources. When setting
up the product, make sure that the AC outlet you
are using is easily accessible. If some trouble or
malfunction occurs, immediately disconnect the all
plugs from the outlet.
Remove the electric plug from the outlet when the product is
not to be used for extended periods of time.
Do not touch the product or the electric plug during an
electrical storm.
Be sure to connect to an appropriate outlet with a protective
grounding connection. Improper grounding can result in
electrical shock, fire, or damage.
If you plan to connect a powered device that complies with
the IEEE802.3 at standards, use a CAT5e or higher-grade
cable. Failure to observe this precaution could result in a fire
or malfunction.
Do not open
This product contains no user-serviceable parts. Do not
attempt to disassemble the internal parts or modify them in
any way.
Water warning/Fire warning
Do not expose the product to rain, use it near water or in
damp or wet conditions, or place on it any containers (such as
vases, bottles or glasses) containing liquids which might spill
into any openings.
Never insert or remove an electric plug with wet hands.
Do not place any burning items or open flames near the
product, since they may cause a fire.
Hearing loss
When turning on the AC power in your audio system, always
turn on the power amplifier LAST, to avoid hearing loss and
speaker damage. When turning the power off, the power
amplifier should be turned off FIRST for the same reason.
CAUTION
Always follow the basic precautions listed below to avoid
the possibility of physical injury to you or others. These
precautions include, but are not limited to, the following:
Power supply/Power cord
When removing the electric plug from the product or an outlet,
always hold the plug itself and not the cord. Pulling by the
cord can damage it.
Location and connection
Do not place the product in an unstable position or a location
with excessive vibration, where it might accidentally fall over
and cause injury.
Do not block the vents. This product has ventilation holes at
the sides to prevent the internal temperature from becoming
too high. In particular, do not place the product on its side or
upside down. Inadequate ventilation can result in overheating,
possibly causing damage to the product(s), or even fire.
PA_en_11 1/2
SWP2 Owner’s Manual
5
When installing the product:
- Do not cover it with any cloth.
- Do not install it on a carpet or rug.
- Make sure the top surface faces up; do not install on its
sides or upside down.
- Do not use the product in a confined, poorly-ventilated
location.
Inadequate ventilation can result in overheating, possibly
causing damage to the product(s), or even fire.
If the product is mounted in an EIA standard rack, carefully
read the section “Precautions for Rack Mounting” on page 9.
Inadequate ventilation can result in overheating, possibly
causing damage to the product(s), malfunction, or even fire.
Do not place the product in a location where it may come into
contact with corrosive gases or salt air. Doing so may result in
malfunction.
Before moving the product, remove all connected cables.
Maintenance
Remove the power plug from the AC outlet when cleaning the
product.
Handling caution
Do not insert your fingers or hands in any gaps or openings on
the product (vents, panel, etc.).
Do not rest your weight on the product or place heavy objects
on it.
This product uses class 1 lasers.
Do not look into the tip of an optical fiber or into an optical
connector. Doing so may damage your eyes.
Backup battery
Do not replace the backup battery by yourself. Doing so may
cause an explosion and/or damage to the product(s).
When the backup battery needs to be replaced, contact your
Yamaha dealer and have qualified Yamaha service personnel
replace the backup battery.
NOTICE
To avoid the possibility of malfunction/ damage to the product,
damage to data, or damage to other property, follow the notices
below.
Handling and maintenance
Do not use the product in the vicinity of a TV, radio, mobile
phone, or other electric products. Otherwise, the product, TV,
or radio may generate noise.
Do not expose the product to excessive dust or vibration, or
extreme cold or heat (such as in direct sunlight, near a heater,
or in a car during the day), in order to prevent the possibility of
panel disfiguration, unstable operation, or damage to the
internal components.
Condensation can occur in the product due to rapid, drastic
changes in ambient temperature—when the product is moved
from one location to another, or air conditioning is turned on or
off, for example. Using the product while condensation is
present can cause damage. If there is reason to believe that
condensation might have occurred, leave the product for
several hours without turning on the power until the
condensation has completely dried out.
Do not place vinyl, plastic or rubber objects on the product,
since this might discolor the panel.
When cleaning the product, use a dry and soft cloth. Do not
use paint thinners, solvents, cleaning fluids, or chemical-
impregnated wiping cloths.
Drain all static electricity from your clothing and body before
handling the device. Static electricity can damage the device.
Touch an exposed metal part of the host device or other
grounded object beforehand.
Do not install the product in a location where magnetic fields
are strong. Otherwise, it might cause the product to
malfunction.
Do not connect any noise generating devices on the same
power line as the product. Failure to observe this precaution
could result in a malfunction or damage to the product.
Do not locate any connected LAN cables close to the power
cord. Otherwise, high voltage might be induced, resulting in
malfunction.
A 1000BASE-T connection will require an Enhanced Category
5 (CAT5e) or better LAN cable.
Saving data
This unit has a built-in backup battery that maintains time
information for the data. When the backup battery runs down,
the time information will be initialized, causing incorrect time
information to be recorded in the log. If this occurs, contact
your dealer or a Yamaha customer service center to have the
backup battery replaced. The life span of the backup battery
is approximately 10 years, but this may vary depending on the
conditions of use. Set the clock after replacing the battery.
Data maintained by the backup battery:
• Time information.
PA_en_11 2/2
SWP2 Owner’s Manual
6
Information
About copyrights
Copying of the software or reproduction of this manual in
whole or in part by any means is expressly forbidden without
the written consent of the manufacturer.
About functions/data bundled with the product
This is a class A product. Operation of this product in a
residential environment could cause radio interference.
This product is a class 1 laser product. It is compliant with
IEC/EN 60825-1, IEC/EN 60825-2, FDA 21 CFR 1002.10, and
1040.10.
IEC 60825-1:2014
Factory: Axcen Photonics Corporation
6F., No.119, Baozhong Rd., Xindian Dist., New Taipei City 231,
Taiwan (R.O.C.)
About this manual
The illustrations as shown in this manual are for instructional
purposes only.
Windows is a registered trademark of Microsoft
®
Corporation
in the United States and other countries.
The company names and product names in this manual are
the trademarks or registered trademarks of their respective
companies.
Software may be revised and updated without prior notice.
About disposal
This product contains recyclable components. When
disposing of this product, please contact the appropriate local
authorities.
Open Source Software Used in this Product
Please refer to Yamaha Pro Audio website for the details of  
licensing article.
http://www.yamahaproaudio.com/
(weee_eu_en_02)
(top_en_01)
Information for users on collection and
disposal of old equipment:
This symbol on the products, packaging, and/
or accompanying documents means that used
electrical and electronic products should not
be mixed with general household waste.
For proper treatment, recovery and recycling of
old products, please take them to applicable
collection points, in accordance with your
national legislation.
By disposing of these products correctly, you will help to
save valuable resources and prevent any potential negative
effects on human health and the environment which could
otherwise arise from inappropriate waste handling.
For more information about collection and recycling of old
products, please contact your local municipality, your waste
disposal service or the point of sale where you purchased
the items.
For business users in the European Union:
If you wish to discard electrical and electronic equipment,
please contact your dealer or supplier for further
information.
Information on Disposal in other Countries outside
the European Union:
This symbol is only valid in the European Union. If you wish
to discard these items, please contact your local authorities
or dealer and ask for the correct method of disposal.
The model number, serial number, power requirements, etc.,
may be found on or near the name plate, which is at the top of
the unit. You should note this serial number in the space
provided below and retain this manual as a permanent record of
your purchase to aid identification in the event of theft.
Model No.
Serial No.
SWP2 Owner’s Manual
7
SOFTWARE LICENCE
AGREEMENT
This agreement is an agreement between you, the customer,
and Yamaha Corporation (hereafter referred to as “Yamaha”)
defining the conditions under which Yamaha provides firmware
for this Yamaha network product (hereafter referred to as the
Product) and related programs, printed material, and electronic
files (hereafter referred to as the Software).
The Software may be used only for the purpose of operating it on
the Product or on a personal computer or similar device. This
agreement applies to the Software provided by Yamaha to the
customer and to copies of the Software created by the customer
in compliance with section 1 subsection (1) of this agreement.
1. Permission to use
(1) The customer may install and use the Software on a Product
or a personal computer or similar device owned by the
customer.
(2) With the exceptions that are explicitly defined by this
agreement, the customer shall not permit the reuse of, sell,
distribute, rent, lease, lend, or transfer the Software, nor
upload it to any website or server where it could be
accessed by specified or unspecified numbers of people,
nor duplicate, translate, adapt it, or rewrite it into any other
program language. The customer shall not correct, revise,
reverse-assemble, reverse-compile, or perform any reverse
engineering of the Software, and may not cause any third
party to perform such actions.
(3) The customer shall not modify, erase, or delete the Yamaha
copyright indications that are included in the Software.
(4) With the exceptions that are explicitly defined by this
agreement, Yamaha does not grant or permit the customer
any of Yamaha's intellectual property rights.
2. Property rights
The Software is protected by copyright law and by other laws,
and is the property of Yamaha. The customer hereby agrees that
no property rights or intellectual property rights related to the
Software are granted by Yamaha to the customer by this
agreement nor any other means.
3. Export restrictions
The customer shall abide by all applicable export regulations
and rules of the relevant countries, and shall not export or re-
export the Software, neither in part nor in whole, in violation of
any applicable rules and regulations.
4. Support and updates
Yamaha, its subsidiaries, their sales representatives and
dealers, and any other party handling or distributing the
Software do not accept any responsibility for maintaining the
Software nor for supporting the customer's use of the Software.
Nor do the aforementioned parties have any responsibility to
update the Software, to fix bugs, or to provide support.
5. Limitation of responsibility
(1) The software is licensed for use “in its current state (as-is).”
Yamaha, its subsidiaries, their sales representatives and
dealers, and any other party handling or distributing the
Software make no warranty, neither explicit nor implicit,
regarding the merchantability or suitability of the Software for
any particular purpose.
(2) Yamaha, its subsidiaries, their sales representatives and
dealers, and any other party handling or distributing the
Software shall bear no responsibility for any damages
(including but not limited to lost profit and any other
consequential or incidental damages) that may arise from
the use of or inability to use the Software. This shall be the
case even if Yamaha, its subsidiaries, their sales
representatives and dealers, or any other party handling or
distributing the Software had been informed of the possibility
of such damages.
(3) Yamaha, its subsidiaries, their sales representatives and
dealers, and any other party handling or distributing the
Software shall bear no responsibility for any dispute between
the customer and a third party that may arise from or related
to the use of the Software.
6. Term of validity
(1) This agreement shall continue in force until it is terminated
by the following sub-sections (2) or (3).
(2) The customer may terminate this agreement by deleting all
instances of the Software that are installed on the Product or
on a personal computer or similar device.
(3) This agreement shall immediately terminate if the customer
violates any of the terms of this agreement.
(4) Upon the termination of this agreement due to sub-section
(3) above, the customer shall immediately delete all
instances of the Software that are installed on the Product or
on a personal computer or similar device.
(5) Regardless of any clauses of this agreement, the provisions
of sections 2 through 6 of this agreement shall continue in
force even after the termination of this agreement.
7. Separability
Even if any clause of this agreement should become invalid, the
remainder of the agreement shall remain in force.
8. U.S. GOVERNMENT RESTRICTED RIGHTS
NOTICE:
The Software is a “commercial item,” as that term is defined at
48 C.F.R. 2.101 (Oct 1995), consisting of “commercial computer
software” and “commercial computer software documentation,”
as such terms are used in 48 C.F.R. 12.212 (Sept 1995).
Consistent with 48 C.F.R. 12.212 and 48 C.F.R. 227.7202-1
through 227.72024 (June 1995), all U.S. Government End Users
shall acquire the Software with only those rights set forth herein.
9. General articles
The customer agrees that this agreement is the complete and
only declaration of agreement between the customer and
Yamaha regarding all matters prescribed by this agreement, and
that it takes precedence over all proposals, prior agreements, or
any other communication between the customer and Yamaha,
whether oral or written. No change to this agreement shall have
any force unless it is signed by a representative who is duly
authorized by Yamaha.
10. Jurisdiction
This agreement shall be under the jurisdiction of the laws of
Japan, and shall be interpreted according to those laws.
SWP2 Owner’s Manual
8
Contents
Introduction 9
Features .................................................................9
Documentation 10
Terms 10
Controls and Functions 11
Front panel ...........................................................11
Rear panel............................................................13
Status Indicator Display 14
LINK/ACT setting .................................................14
STATUS setting ....................................................14
VLAN setting ........................................................14
OFF setting...........................................................14
Initializing the SWP2 14
Using the Web GUI to restore the factory settings
.............................................................................14
Using the cold start command to restore the factory
settings.................................................................15
Entering the <I> (uppercase I) key during startup to
restore the factory settings ..................................15
VLAN Use Cases 16
Redundant Dante connections ............................16
Separating control signals from audio signals.....16
Specifications 17
SWP2 Owner’s Manual
9
Introduction
Thank you for choosing the Yamaha SWP2-10MMF, or
SWP2-10SMF L2 switch.
To take full advantage of the superior functions and
performance offered by the SWP2, and to enjoy years of
trouble-free use, be sure to read this owner’s manual
carefully before operation.
This owner’s manual is intended to be read by audio
networking personnel.
Included items
SWP2 Owners Manual (this book)
Power cord (three-pin plug)
Option item
PA-700 (AC adaptor)
* This can be connected to the rear panel [EXT DC INPUT] jack
and used as a backup for the internal power supply.
Precautions for Rack Mounting
This unit is rated for operation at ambient temperatures
ranging from 0 to 40 degrees Celsius. When mounting
the unit with other SWP2 unit(s) or other device(s) in an
EIA standard equipment rack, internal temperatures can
exceed the specified upper limit, resulting in impaired
performance or failure. When rack mounting the unit,
always observe the following requirements to avoid heat
buildup:
When mounting the unit in a rack with devices such as
power amplifiers that generate a significant amount of
heat, leave more than 1U of space between the SWP2
and other equipment. Also either leave the open
spaces uncovered or install appropriate ventilating
panels to minimize the possibility of heat buildup.
To ensure sufficient airflow, leave the rear of the rack
open and position it at least 10 centimeters from walls
or other surfaces. If you’ve installed a fan kit, there
may be cases in which closing the rear of the rack will
produce a greater cooling effect. Refer to the rack
and/or fan unit manual for details.
Features
Recommended settings for Dante are
provided
Recommended settings (such as QoS, EEE, and IGMP
Snooping) for stable operation of the Dante network
can be specified with only DIP switch. The 10GBASE-
SR/LR ports support 10 gigabit, allowing operation
without fear of insufficient bandwidth even on a Dante
network that is set to a sampling frequency of 96 kHz.
VLAN presets provided
Three types of preset VLAN settings are provided,
allowing a more stable network to be constructed by
dividing audio signals and control signals with a single
SWP2 unit. The user can also customize the settings.
Visualize the network status
The “Yamaha Audio Network Monitor” Windows
application allows you to monitor the status of the
network and the Dante devices. The unit’s indicators
also show which VLAN is connected to which port.
Hardware that supports safety and peace of
mind
All models can be rack-mounted. In consideration of
temporary setups or other environments in which
cables are liable to be pulled out, etherCON and
opticalCON are provided as standard. In addition to
an AC IN jack with V-lock, an XLR-4-32 type EXT DC
INPUT jack is also provided. Redundant power can be
provided by using a PA-700 or other external power
supply (+24V).
Related software
If you are using VLAN, connect the computer to the
VLAN 1 port.
Yamaha Audio Network Monitor (Windows
application)
This is used to monitor the entire network, including
SWP2 data as well as all Dante devices on the Dante
network.
Download this application from the following website.
http://www.yamahaproaudio.com/
•Web GUI
Use this to view or edit the settings of SWP2 units on
the network from a web browser.
Access the Web GUI from the Yamaha Audio Network
Monitor.
To use the Web GUI, connect a computer to the VLAN
1 port.
When accessing the Web GUI, the “Windows Security”
dialog box may appear. With the factory settings, the
administrative password is set as follows.
User name
(blank)
Password
(blank)
SWP2 Owner’s Manual
10
Documentation
In addition to this manual, the following documentation
for the SWP2 is available.
Yamaha Audio Network Monitor Users
Guide (PDF)
This explains installation, settings, and usage of the
“Yamaha Audio Network Monitor” Windows
application.
Command References (PDF)
This explains the commands used when making
settings from the command line of a computer.
Technical Data (HTML)
This explains details of the SWP2’s functions.
These documents can be downloaded from the links in
the product page of the following website.
http://www.yamahaproaudio.com/
Terms
•VLAN
This stands for Virtual Local Area Network. A virtual
network is constructed separately from the physical
connections. When there are multiple networks of
differing types, setting up a VLAN allows a logically
separate network to be constructed that shares the
same physical switches.
A VLAN can be either a “Port-based VLAN” which
constructs groups using a physical connection for
each port, or a “Tag VLAN” which differentiates VLAN
groups by assigning a tag to each Ethernet frame.
In the case of a port-based VLAN, each VLAN requires
a connection to communicate with another switch.
Using a tag VLAN allows multiple VLANs to be
combined into a single trunk connection (cable) that
connects switches, ensure that the total amount of
data does not exceed 1 Gbps for the LAN ports or
10 Gbps for the 10GBASE-SR/LR ports. The VLAN
preset A and B of the SWP2 use tag VLAN.
Link aggregation
Link aggregation is a function that bundles multiple
LAN/SFP+ ports that connect network devices, and
treats them as a single logical interface in order to
expand the communication bandwidth. A group that is
bundled using link aggregation is called a link
aggregation group (LAG).
Link aggregation is a technology that is useful when
multiple communications are occurring. The
communications can be distributed between the
aggregated connections by using a load balancing
function. Since load balancing distributes the load
according to IP address, we recommend that you fix
the IP addresses of each device in order to stabilize
load balancing.
Even if a problem occurs on one of the LAN/SFP+
ports that are bundled by link aggregation, so that this
port is unable to communicate, communication will
continue via the remaining ports.
Trunk
This function adds tags to multiple VLANs so that they
can be transmitted and received via a single
connection. When one SWP2 transmits VLAN 1 data
via the trunk connection, the SWP2 unit that receives
this will transmit the data only to the port that
corresponds to its own VLAN 1.
Communication speed for a metal trunk connection on
the SWP2’s VLAN preset B is 1 Gbps per cable. If
there is only one cable, and the total bandwidth
passing through the trunk connection exceeds
1 Gbps, packets will be delayed or dropped. Some of
the SWP2’s VLAN presets enable link aggregation of
the trunk connection. If the bandwidth will exceed
1 Gbps for a LAN port or 10 Gbps for a 10GBASE-SR/
LR port, or if you want to provide redundancy to guard
against cable breakage, you should use two trunk
cables.
: VLAN 1 port
: VLAN 2 port
: Trunk port
: Data flow
SWP2 Owner’s Manual
11
Controls and Functions
Front panel
The explanation here is based on the SWP2-10MMF.
LAN ports
These are etherCON (RJ-45) ports for connecting
Ethernet cables (CAT5e or better is recommended).
A cable with an RJ-45 connector can also be
connected.
All ports support 1000BASE-T, 100BASE-TX, and
10BASE-T.
10GBASE-SR ports (SWP2-10MMF)/
10GBASE-LR ports (SWP2-10SMF)
This is an opticalCON DUO port for connecting an
optical fiber cable. LC Duplex connectors can also
be connected.
If you use a cable with an LC Duplex connector,
fasten the dust cap attached to the cable connector
to prevent dust from adhering when the cable is not
in use.
NOTE
Use an opticalCON DUO optical fiber cable made by
Neutrik Corporation. Since optical fiber cables are
vulnerable to being bent or pulled, you can reduce the
occurrence of problems by using a cable that has a
strong sheath and is equipped with a locking mechanism.
The SWP2-10MMF can use GI-type multi-mode fiber
cables that have a core diameter of approximately 50 μm
and cladding diameter of approximately 125 μm. The
maximum length between devices is 300 m.
The SWP2-10SMF can use SM-type single-mode fiber
cables with a core diameter of approximately 9 μm and a
cladding diameter of approximately 125 μm. The
maximum length between devices is 10 km.
In some cases, the specifications might not be satisfied
because of the optical fiber cables that are used and the
conditions of installation.
Link up is possible only for 10GBASE-SR/LR between the
same standards. 10GBASE-SR/LR can not link up with
1000BASE optical standards.
Cleaning
Correct communication might not be possible if
debris and/or dust has adhered to the ends of optical
fiber cables or the ports. Clean the equipment
regularly by using commercially available optical
fiber cleaning products.
LED mode indicators
This indicates what the status indicators are showing.
[LED MODE] button
This switches what the status indicators are showing.
Status indicators
These indicate the status of each port. The displayed
content depends on the mode. For details on the
display in each mode, refer to “Status indicator
display.”
DIP switches
These specify startup settings for the unit.
Set the DIP switches when the power is turned off.
The settings are not applied if you change the setting
while the power is on.
The switch illustrations indicate the up/down position
as follows.
Switch 1 (CONFIG)
Specifies whether the unit’s settings are optimized for
a Dante network or are set by the user.
Switch
position
Status
Represent a status with switch toggled up.
Represent a status with switch toggled
down.
Switch
position
Option Functions
DANTE
The unit starts up with settings
optimized for a Dante network.
This setting is read only.
USER
The unit starts up with user
settings. This setting can be
read or written; when you
change the setting, the unit
starts up the next time as well
with that setting.
1
1
SWP2 Owner’s Manual
12
Caution when using this unit
together with another
manufacturer’s switch
Dante supports both IGMP V2 and V3, but you must set
all switches in the same network to operate using the
same version.
If the SWP2 starts up with DANTE settings, it operates
using IGMP V3. In this case, if the network includes
even one switch that is operating with IGMP V2,
problems such as dropouts in the sound might occur.
Switch 2 and 3 (VLAN PRESET)
Specifies the VLAN preset that is used when switch 1
is in the [DANTE] position. This setting is ignored if
switch 1 is set to [USER].
If you change the settings via the web GUI or a
command, the settings are applied temporarily but is
not stored; the next time the unit starts up, it returns
to the VLAN preset setting.
In the tables, “1,” “2,” “Tr1,” and “Tr2” respectively
indicate VLAN 1, VLAN 2, trunk (LAG1), and trunk
(LAG2).
For an explanation of VLAN, trunk, link aggregation,
and LAG, refer to Terms on page 10. For details, you
can download technical reference material (HTML).
(*1) In the VLAN presets, the IGMP Snooping function is
turned on except for VLAN 2 in presets A and B,
preventing multicast communication such as Dante
s
multicast flow from being forwarded to unnecessary
routes. For this reason, in the case of A or B you
should use the VLAN 1 port for audio signals such as
Dante, and use the VLAN 2 port for control signals.
(*2) If you use setting C, connect the computer that is
using Yamaha Audio Network Monitor to the VLAN 1
port.
[CONSOLE (RS-232C)] port
This is an RJ-45 port used to specify commands.
Use an RJ-45/DB-9 serial cable to connect this to the
RS-232C port (COM port) of your computer. Use an
RJ-45/DB-9 serial cable that is wired as described in
“Specifications.”
[POWER] indicator
This is lit when the SWP2 is powered-on.
Switch
position
Option Functions
NORMAL
The following table shows how
the VLAN and trunk are
assigned to ports.
A
B
C
VLAN
PRESET
Rear panel ports
123456
NORMAL 111111
A (*1) 1111
2 2
B (*1) 1111
2 2
C (*2) 111
2 2 2
VLAN
PRESET
Front panel ports
789101112
NORMAL 111111
A (*1) 1 1
2 2 Tr1 Tr1
B (*1) 1
2 Tr1 Tr1 Tr2 Tr2
C (*2) 1 1
2 2 1 2
2 3
2 3
2 3
2 3
SWP2 Owner’s Manual
13
Rear panel
Grounding screw
Since the included power cord has a three-pin plug,
this unit will be appropriately grounded if the AC
outlet is grounded. In some cases, you may be able
to reduce hum noise and interference noise by
connecting this screw to ground as well.
AC IN connector
Connect the included power cord here. First connect
the power cord to this unit, and then connect the
power supply plug to an AC outlet; the SWP2’s
internal power supply turns on.
The supplied AC power cord features a V-lock
mechanism via a latch, which prevents the power
cord from coming off accidentally.
Insert the cable plug all the way until it locks in
securely.
Press the latch button on the plug to disconnect the
power cord.
[EXT DC INPUT] connector
This is an XLR-4-32 type jack for supplying an
external power supply (+24V) as a backup for the
SWP2’s internal power supply.
Connect a Yamaha PA-700 AC adaptor or an
equivalent product recommended by Yamaha.
CAUTION
Before connecting the external power supply, you
must turn off the external power supply. Failing to do
so may cause electrocution or malfunctions.
EXT DC INPUT connector is intended to be supplied
by Power Supply certified with “Limited Power
Source” or “LPS” and rated 24 Vdc.
NOTE
If an external power supply is connected, the SWP2 will
operate normally when its internal power supply and the
external power supply are on, as well as when only one is
on.
If both power supplies are on, and one of them is
interrupted during operation, the unit will continue to
operate normally.
LAN ports
These are etherCON (RJ-45) ports for connecting
Ethernet cables (CAT5e or better is recommended).
A cable with an RJ-45 connector can also be
connected.
All ports support 1000BASE-T, 100BASE-TX, and
10BASE-T.
SWP2 Owner’s Manual
14
Status Indicator Display
The status indicators show different things depending on
the LED mode setting.
LINK/ACT setting
The status indicators show each ports link status and
connection status.
STATUS setting
The status indicators show the loop-related port’s status.
VLAN setting
The status indicators show the VLAN ID and trunk.
If DIP switch 1 is upward ([DANTE]), VLAN 1 is shown by
the upper indicator and the lower indicator unlit. VLAN 2
is shown by the upper indicator lit green and the lower
indicator unlit. Trunk is shown by upper and lower
indicators lit orange.
–: Unlit
G: Lit green
O: Lit orange
NOTE
If a number of VLANs that cannot be completely displayed
above is specified, the upper and lower indicators are lit
green.
If multiple VLAN IDs are specified for the same port, the
upper and lower indicators are lit orange.
OFF setting
All status indicators are unlit.
Initializing the SWP2
Here’s how to initialize the SWP2’s internal memory,
restoring it to the factory settings.
CAUTION
Do not turn off the power to the SWP2 during initialization.
Otherwise, a malfunction may occur.
NOTE
If initialization failed, contact Yamaha service personnel.
The SWP2 can be restored to its factory-set state in the
following ways.
Using the Web GUI to restore the factory settings
Using the cold start command to restore the factory
settings
Entering the <I> (uppercase I) key during startup to
restore the factory settings
NOTICE
When restoring the factory settings, note the following
points.
All communication is halted immediately after execution.
When you execute this, the settings will also return to
their factory-set state. If necessary, use external memory
to save the settings before you proceed with initialization.
For details on how to export settings to external memory,
refer to the “SWP2 series technical data.
Using the Web GUI to restore
the factory settings
The SWP2 can be restored to its factory-set state by
making settings from the Web GUI.
Log in to the Web GUI from Yamaha LAN Monitor.
1. Choose [Management] tab – [Maintenance]
– [Restart and initialize].
The “Restart or Initialize” screen appears.
2. In the “Initialize” section, click the [Next]
button.
The “Initialize” screen appears.
3. Enter the administrative password, and
click the [OK] button.
The “Check executed content” screen appears.
Since an administrator password is not specified
when the unit is shipped from the factory, leave the
field empty if this is still the case.
Indicator Illumination Status
Upper
Lit green Link is established. (LINK)
Flashing
green
Data is being transferred.
(ACT)
Unlit Link is lost.
Lower
Lit green
Connected with 1000BASE-T
or 10GBASE-SR/LR.
Lit orange Connected with 100BASE-TX.
Unlit Connected with 10BASE-T.
Indicator Illumination Status
Upper
and lower
Flashing
orange
Loop was detected and
communication was halted, or
an abnormality in the
opticalCON light reception
level was detected.
Unlit
Loop not detected. Or loop
was detected, but
communication is not halted.
Indicators
1
VLAN ID low high
Trunk
Upper GO GO O
Lower G O O G O
SWP2 Owner’s Manual
15
4. Verify the content, and click the [Execute]
button.
The SWP2 is returned to its factory-set state. Then,
the “Initialization” dialog box appears, and the
SWP2 restarts.
5. After this unit has finished restarting,
access the Web GUI once again from
Yamaha LAN Monitor.
NOTE
During restart, the computer on which the Web GUI is
open will be unable to communicate with the unit (the
status indication of the computer’s network adapter will
be “Network cable is not connected”), but the
communication status will recover when restart is
completed. After this SWP2’s POWER indicator has
finished flashing, verify that communication has been
restored for the computer on which the Web GUI is open,
and then click the [Web GUI] button in the “Device
Details” view.
Using the cold start command
to restore the factory settings
You can return the unit to its factory settings by using a
command line setting via the CONSOLE port, Telnet, or
an SSH client.
Here we assume that you are logged in as described in
“Logging in from a computer connected to the
CONSOLE port”.
Preparing the computer
You will need terminal software that controls the serial
(COM) port of the computer.
Set the parameters of the terminal software as follows.
1. Using a console cable, connect the SWP2
to the computer.
Connect the computer to the CONSOLE port of
SWP2 using an RJ-45/DB-9 console cable.
2. Check the power supply of SWP2.
If the SWP2 is not powered-on, turn on the power
as described in “AC IN connector” (page 13).
When this unit powers-on and the command line is
usable, a startup message appears in the console
screen of the computer.
If the power is already on, a startup message does
not appear.
3. Press the <Enter> key.
The system waits for a user name to be entered. If
a user name has already been specified, enter the
user name. When the unit is shipped from the
factory, a user name has not been specified, so it
need not be entered.
4. Press the <Enter> key.
The system waits for a password to be entered.
If a password has already been specified, enter
the password.
When the unit is shipped from the factory, a
password has not been specified, so it need not be
entered.
5. Press the <Enter> key.
If password authentication is successful, the
command prompt appears, allowing you to enter
commands.
6. Enter enable, and press the <Enter> key.
You are now in privileged EXEC mode.
7. Enter the cold start command, and press
the <Enter> key.
You will be asked to enter the administrative
password.
If a password has already been specified, enter
the password.
When the unit is shipped from the factory, a
password has not been specified, so it need not be
entered.
8. Press the <Enter> key.
The SWP2 returns to the factory-set state, and then
restarts.
Entering the <I> (uppercase I)
key during startup to restore
the factory settings
The SWP2 can be restored to its factory settings by
entering an uppercase <I> when the SWP2 is starting
up. This explanation uses the method of disconnecting
and reconnecting the power cord. The procedure is also
the same when using the reload command to restart the
SWP2.
Our explanation here assumes that you have performed
steps 1 of “Using the cold start command to restore to
the factory settings.”
1. Disconnect and then reconnect the power
cord of SWP2.
2. During restart, enter an uppercase <I>
within one second after the BootROM Ver
appears on the console screen.
Parameter Value
Data transmission speed 9600bps
Character bit length 8
Parity check None
Number of stop bits 1
Flow control Xon/Xoff
SWP2 Owner’s Manual
16
3. When a screen asks you whether to
execute initialization, press the <y> key to
execute initialization.
Initialization is executed.
VLAN Use Cases
Redundant Dante connections
This case double the cables between devices as a
safeguard against cable breakage. This diagram shows
a setup using VLAN preset C.
Separating control signals
from audio signals
This case logically separates control signals such as for
Editor or StageMix from Dante’s audio signals, making
the network more stable. This diagram shows a setup
using VLAN preset B.
If VLANs are not used, and control signals and audio
signals flow across the same network, the two will
compete for communication bandwidth. In order to
prevent such an effect, we recommend that you use
VLANs to separate the control signal and audio signal
networks.
PSPSPS
PS PSPS
PS
VLAN 1 (Primary)
VLAN 2 (Secondary)
SWP2
(VLAN
preset
= C)
SWP2
(VLAN
preset
= C)
StageMix
StageMix
VLAN 1 (Audio)
VLAN 2 (Control)
Trunk (LAG1)
Trunk (LAG2)
SWP2
(VLAN preset = B)
SWP2
(VLAN preset = B)
SWP2
(VLAN preset = B)
Editor
SWP2 Owner’s Manual
17
Specifications
GENERAL SPECIFICATIONS
*1 The LED MODE button allows the PORT indicators to be switched between indicating LINK/ACT-SPEED, STATUS, or VLAN.
PARAMETER SWP2-10MMF SWP2-10SMF
Number of LAN ports
(1000BASE-T/100BASE-TX/10BASE-T,
etherCON connector)
10
Number of SFP+ ports
(10GBASE-SR, opticalCON DUO connector)
20
Number of SFP+ ports
(10GBASE-LR, opticalCON DUO connector)
02
Console port 1 (RJ-45)
Automatic negotiation Available
Auto MDI/MDI-X Available
DIP switches CONFIG, VLAN PRESET
Indicators (Front) POWER, LED MODE×4
PORT×10×2
*1
, SFP+×2×2
Operating temperature range 0 to 40°C
Storage temperature range -20 to 60°C
Power supply (AC IN inlet) AC100V – 240V, 50/60 Hz, Internal power supply (no power switch)
Power supply inlet: locking type
Power supply (EXT DC INPUT inlet) 24VDC±2V, 0.78A, XLR-4-32 type Connector
Maximum power consumption
(Wattage, Current)
21W, 0.35A
Heat dissipation 18.5 kcal/h
Body material Metal case, no fan
Hazardous substances management RoHS compliant
Dimensions (W x H x D) 480 x 44 x 362 mm (18-7/8" x 1-3/4" x 14-1/4")
Weight (excluding accessories) 4.5 kg (9.9 lbs)
Accessories Power cord, Owner’s manual
Option item PA-700 (AC adaptor)
SWP2 Owner’s Manual
18
INTERFACE SPECIFICATIONS
*1 These terminals support AutoMDI/MDI-X
*2 Conforming cable: SWP2-10MMF: GI-type multi-mode fiber cables with a core diameter /cladding diameter of approximately 50 μm/
125 μm. Maximum cable length: 300 m
SWP2-10SMF: SM-type single-mode fiber cables with a core diameter /cladding diameter of approximately 9 μm/
125 μm. Maximum cable length: 10 km
*3 10GBASE-SR: SWP2-10MMF, 10GBASE-LR: SWP2-10SMF
*4 For the pin assignments, refer to CONNECTOR PIN ASSIGNMENTS
*5 Pin 4=+24VDC, pin 1=GND, pins 2 and 3=N.C.
External power supply requirements: 24VDC±2V, 0.78A
CONNECTOR PIN ASSIGNMENTS
CONSOLE (RS-232C)
* These signals are not used on the SWP2.
Terminal Format Level Connector
1-10
*1
IEEE802.3 10BASE-T/100BASE-TX/
1000BASE-T
etherCON CAT5e
11, 12
*2
IEEE802.3ae 10GBASE-SR 10GBASE-LR
*3
opticalCON
CONSOLE (RS-232C) RS-232C RJ-45
*4
EXT DC INPUT XLR-4-32 type
*5
Signal RJ45 D-SUB 9
9
RTS 1 8
DTR 2 6
TxD 3 2
GND 4 5
GND 5
RxD 6 3
DSR* 7 4
CTS* 8 7
1
SWP2 Owner’s Manual
19
Dimensions
* The contents of this manual apply to the specifications as of the firmware Rev. 2.03.01. To obtain the latest manual, access the Yamaha
website then download the manual file.
Unit: mm
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Yamaha SWP2 Manuale del proprietario

Categoria
Apparecchiature musicali supplementari
Tipo
Manuale del proprietario