User Instructions
PM1940.2.06.2021
Istruzioni per l’utilizzo
Instructions d’utilisation
Studio
Cassette & Freestanding Range
2
GENERAL POINTS
IMPORTANT
THE OUTER CASING, FRONT AND GLASS PANEL BECOME
EXTREMELY HOT DURING OPERATION AND WILL
RESULT IN SERIOUS INJURY AND BURNS IF TOUCHED.
IT IS THEREFORE RECOMMENDED THAT A FIREGUARD
COMPLYING WITH BS 8423 (LATEST EDITION) IS USED IN
THE PRESENCE OF YOUNG CHILDREN, THE ELDERLY OR
INFIRM.
Do not attempt to burn rubbish in this appliance. Please read
these Instructions carefully before installation or use.
Keep them in a safe place for future reference and when servicing
the fire. Before installation and/or use of this appliance please
read these instructions fully and carefully to ensure that you have
fully understood their requirements.
The appliance must be fitted by a registered installer, or
approved by your local building control officer.
All local regulations, including those referring to national and
European Standards need to be complied with when installing the
appliance.
Only use for domestic heating in accordance with these operating
instructions.
You must burn only approved fuels. Do not use with liquid fuels or
as an incinerator.
Appliance surfaces become very hot when in use. Use a suitable
fireguard if young children, elderly or infirm persons are present.
Stovax offer firescreens, sparkguards and hearthgate systems
for protection. Your Stovax dealer can advise you about these
products.
Do not place photographs, TV’s, paintings, porcelain or other
combustible items on the wall or near the appliance. Exposure
to hot temperatures will cause damage. Do not place furniture or
other items such as drying clothing closer than 1m from the front
of this appliance.
WARNING: Extra fuel should not be stored on or next to the
appliance. Only keep enough fuel for immediate use nearby and
never leave the appliance unattended for long periods with any
combustible material in close proximity.
Extractor fans or cooker hoods must not be placed in the same
room or space as this can cause appliance to emit fumes into the
room.
Do not obstruct inside or outside ventilation required for the safe
use of this appliance.
Do not make unauthorised changes to the appliance.
The chimney must be swept at least once a year.
Do not connect, or share, the same flue or chimney system with
another appliance.
WARNING
Properly installed, operated and maintained this
appliance will not emit fumes into the room but
occasional fumes from de-ashing and refuelling
may occur.
Persistent fume emission is potentially dangerous
and must not be tolerated.
If fume emission persists:
Open doors and windows to ventilate the room.
Leave the room.
Allow fire to burn out or safely dispose of fuel
from the appliance.
Check for chimney blockage and clean if
required.
Do not attempt to relight until the cause of the
emission has been identified and corrected.
If necessary seek expert advice.
All open flued appliances can be affected by
temporary atmospheric conditions which may
allow fumes to enter the house. Because of
this an electronic carbon monoxide detector
conforming to the latest edition of BSEN50291
must be fitted in the same room as the
appliance. The existence of an alarm must not
be considered a substitute for ensuring regular
servicing and maintenance of the appliance
and chimney system.
IF THE ALARM SOUNDS FOLLOW THE
INSTRUCTIONS GIVEN ABOVE.
IMPORTANT: Stovax provide gauntlet style gloves
for the users protection from heat and any sharp
edges when using the appliance.
For your safety ensure that gloves are always worn
when opening, operating, refuelling or handling
internal metalwork.
GB
Data Plate
Studio 3 Data plate only
accessible when door is closed
This number is required when ordering spare parts or making
warranty claims.
The data plate is found:
SERIAL NUMBER
3
GETTING STARTED
OPENING THE DOOR
STUDIO 500, 1 & 2
Stovax products are designed to produce secondary heating for your home and are designed to
minimise atmospheric emissions which come from the burning of wood.
However, this does require the following lighting technique and good quality fuel to optimise the
start-up of the stove and get the flue up to operating temperature.
Stovax recommend you familiarise yourself with the operation of the fire, the correct type of
seasoned fuel and stacking methods in order to get the best performance from your appliance.
Effect, cleaning burn is achieved by the right flue draft conditions and the quality of the fuel
used. Experience will help establish the preferred settings for use and ensure the optimum fuel
consumption.
CLEAN BURNING & YOUR STOVE
• Set the air controls to 50% to keep the appliance ventilated and stop
the build-up of any moisture inside when the appliance is not in use for
long periods of time.
• If there is still burning fuel in the firebox, do not shut down the air
controls completely unless there is a chimney fire in progress
• Closing the controls during the burning process will cause poor
combustion and could lead to a build up of gasses that could ignite
dangerously.
Always have enough air entering the stove to maintain some flame within
the firebox.
• If it is necessary to shut down the appliance then run on a high setting
until all of the fuel has been burnt before closing the air controls.
AIR CONTROLS
GB
OPEN
CLOSED
STUDIO 3
Airwash Control
Secondary
Air Inlet -
Factory Set
Primary Control
4
LIGHTING
Air Wash: Fully Open
Primary Air: Fully Open
To create an open stack for top down lighting:
Place two medium sized logs parallel on the base of the
firebox.
Place two smaller logs on top running parallel across the
bottom logs.
Continue to build the stack using smaller logs and place
firelighters in the centre.
Finish the stack by adding two further logs and placing
firelighters on top.
Add extra smaller kindling.
1
2
3
4
NOTE: Kindling is essential to allow the firebox to reach the
correct operating temperature quickly. Incorrect start up can lead to
excessive smoke and the fire going out when the door is shut.
A successful fire initially requires plenty of kindling to establish a
hot firebox and warm the chimney to aid flue performance.
Kindling:
Finely chopped wood
Length 250mm
Diameter: 20mm
Weight per lighting: 2.0 kg (approx 8-12 finely chopped pieces)
Close the door immediately to prevent excess products of
combustion entering the room.
Be sure to use split logs and not whole pieces of wood. Too
much fuel in the firebox will cause the appliance to reach
higher temperatures than intended.
This can damage the interior components of the fire.
Suggested Loads:
Studio 500 - 2/3 logs no bigger than 5" (80mm) diameter
Studio 1 & 2 - 3/4 logs no bigger than 5" (127mm) diameter
Studio 3 - 4/5 logs no bigger than 5" (127mm) diameter
Fuel Loading:
These are wide appliances and the logs should be laid out in a
single layer with gaps between
WARNING: DO NOT OPERATE THE APPLIANCE WITH THE
PRIMARY AIR CONTROL OPEN FOR LONG PERIODS OF TIME
AS THIS COULD CAUSE OVER-FIRING AND MAY CAUSE
PERMANENT DAMAGE.
USING THE APPLIANCE FOR THE FIRST TIME
To allow the appliance to settle, and fixing glues and
paint to fully cure, operate the appliance at a low
temperature for first few days.
Do not touch the paint during the first period of use.
During this time the appliance may give off some
unpleasant odours. Keep the room well ventilated to
avoid a build-up of fumes.
Please be aware that, during use, rope seals may
discolour. This is normal.
GB
5
RUNNING THE APPLIANCE
BURNING WOOD
Close the Primary air control and use the Airwash to control the
burn rate when appliance is at operating temperature
Air Wash: Adjust Burn RateAir Wash: Adjust Burn Rate
Primary Air: ClosePrimary Air: Close
MinMin
MaxMax
Wood burns best on a bed of ash (approx. 25mm (1") deep).
Do not burn large amounts of fuel with the Airwash Control
closed for long periods of time. This reduces the glass cleaning
effect of the Airwash and causes tars and creosotes to build-up in
the appliance and flue system.
When in use, burning the appliance at a high temperature for a
short period reduces tars and creosotes.
WARNING: DO NOT OPERATE THE APPLIANCE
WITH THE PRIMARY AIR CONTROL OPEN FOR
LONG PERIODS OF TIME AS THIS COULD CAUSE
OVER-FIRING AND MAY CAUSE PERMANENT
DAMAGE.
Experience establishes settings to suit personal preference.
REFUELLING
Open the Primary Air and Airwash controls fully.
Rake the embers evenly over the firebed to establish a
glowing firebed. If the firebed is low add a small amount of
kindling wood to help re-establish the fire.
Do not refuel when a large amount of flames are in the
firebox as this could cause smoke or flames to spill into the
room.
Close the doors immediately after refuelling.
These are wide appliances and the logs should be laid out in a
single layer with gaps between.
Do not stack the logs on top of each other as this could effect
the efficiency.
DO NOT OVERLOAD THE APPLIANCE AS TOO MUCH FUEL
COULD CAUSE IT TO OVER-FIRE.
After refuelling:
Burn the new logs at high output for a few minutes before
closing the Primary Air control. Adjust the burn rate using the
Airwash control.
Do not close the air controls until the fire is burning well.
Do not burn large amounts of fuel with the Airwash control
closed for long periods of time. This reduces the glass cleaning
effect, causes tars and creosotes to build-up in the appliance and
flue system and will produce excessive amounts of smoke.
When running the appliance refuel little and often for clean,
efficient burning.
A bright and clean firebox indicates the appliance is burning
well.
Do not burn continuously with the door open.
RECOMMENDED FUELS
WOOD LOGS:
Burn only seasoned timber with a moisture content of less than
20%. To ensure this allow cut wood to dry for 12 to 18 months.
Wood Length
Appliance Wood LengthWood Length
Studio 500 Up to 250mm
Studio 1 250mm - 300mm
Studio 2 250mm - 400mm
Studio 3 250mm - 500mm
Poor quality timber:
— Causes low combustion efficiency
— Produces harmful condensation
— Reduces effectiveness of the airwash and life of
the appliance
DO NOT BURN construction timber, painted, impregnated /
treated wood, manufactured board products or pallet wood.
DO NOT USE any form of candle as fuel. Melted wax will
damage the appliances moving parts.
DESCRIPTION
FUEL CONSUMPTION
KG/HOUR
WOOD
Studio 500
1.62
Studio 1
1.6
Studio 2 2.7
Studio 3 4.0
A number of factors can affect the performance of the appliance.
See Troubleshooting Section for details.
GB
6
FUEL OVERLOADING
The maximum amount of fuel specified in this manual should not be
exceeded, overloading can cause excess smoke.
CHOOSING FUEL:
All types of wood can be used as fuel in the appliance. Different
types of wood have different densities: the greater the density of
the wood the greater the energy value.
Oak, beech and birch have the highest value.
The correct moisture content for firewood that is ready to burn is
below 20% moisture content.
If wood is too wet, it will be difficult to light, struggle to burn, give
very little heat output and tar up the flue.
This could lead to a chimney fire, so it is important to burn
sufficiently dried firewood.
Dry wood gives more heat output, avoids blackening the appliance
glass and there is minimal soot build up in the chimney or flue.
More heat output equals less fuel.
Do not burn construction timber, painted,
impregnated / treated wood, manufactured board
products or pallet wood.
Wood Storage:
To ensure thoroughly dry wood, cut in winter and store under a roof
with plenty off room for air circulation.
Do not cover completely, leave a gap for air to pass over the wood
and do not seal.
Bring wood intended for use inside and store for a few days
prior to burning to ensure that the moisture has been sufficiently
decreased.
ASH REMOVAL
Wood burns best on a bed of ash
Do not allow ash to build up in the appliance as it will not burn
properly and may cause damage.
Remove ash with a small shovel (available from Stovax). Take care
not to damage the ceramic lining of the appliance.
Do not use sharp pointed pokers.
Remove ash carefully - heat can remain long after use.
Carefully place the ash into a Stovax Ash Caddy.
Do not place hot ash in a container made from plastic or any
other combustible material.
OVER-FIRING
Do not over-fill with fuel or run at high temperatures for long periods
or over-firing can occur.
DO NOT OPERATE THE APPLIANCE WITH THE PRIMARY
AIR CONTROL OPEN FOR LONG PERIODS OF TIME AS THIS
COULD CAUSE OVER-FIRING AND MAY CAUSE PERMANENT
DAMAGE.
Over-firing can cause permanent damage to the appliance and
invalid the product warranty.
CHIMNEY FIRE
If a chimney fire occurs:
Shut all air controls immediately.
Evacuate the building.
Call the fire brigade.
Do not re-enter the building until it is confirmed safe.
Do not use the appliance after a chimney fire until:
a) It has been inspected by a registered installer, confirming
the appliance is safe to use.
b) The chimney system has been inspected and swept by a
chimney sweep, confirming the system is structurally sound and
free from obstruction*.
c) It is repaired as required before re-use. Use only genuine
Stovax replacement parts to keep your appliance in safe, efficient
working order.
GB
7
GENERAL CLEANING
Clean and inspect the appliance regularly, especially in periods of
heavy use. Regular cleaning and maintenance will help give many
years of safe use.
Allow appliance to cool thoroughly to avoid risk of burns.
Clean regularly, according to level of use.
Remove the ash completely.
Check internal components for damage - grates, bricks, baffles
- and for obvious build up of soot, ash or debris above the flue
baffle(s) (these can be found in the upper part of the firebox). Use
a torch if necessary.
If there are any signs of a build up of debris above the flue baffle(s)
either:
Arrange for the chimney to be swept.
Remove the baffles and clear the debris.
To refresh painted nishes a touch up spray is available.
Contact your Stovax retailer quoting the serial number found on
the appliance data badge.
Do not use aerosol sprays near an operating appliance.
CLEANING GLASS
Keep the glass clean with correct use of the Airwash system and
good quality fuel.
Sometimes additional cleaning may be required.
Before undertaking this operation allow appliance to cool fully. Do
not clean hot glass.
On appliances with printed glass do not use cleaning
agents that have a high alkaline or acidic content, these are
aggressive cleaning agents designed to be used with heavily
stained clear glass. On printed glass surfaces, use Stovax
Glass Cleaner (Stovax No.4103) which is better formulated for
this application.
Before applying a cleaning agent remove any dust and loose soot
with a damp cloth.
Use an appropriate glass cleaner. Apply the cleaning fluid to a
cloth before rubbing onto the glass.
Apply carefully and do not apply excessively. Try to prevent any
run off which could soak into the rope seals around the edge of the
glass.
Soot can also contain acidic particles that can cause corrosive
damage to printed glass.
Remove dirt with a moist cloth and buff dry.
Some types of wood can cause a white residue to form on the
glass.
If this occurs it should be cleaned off at least once a week
during periods of heavy usage.
If the liquid cleaning agents recommended do not remove
this residue Stovax offer a dry cleaning pad which will help
remove heavy stains.
Before relighting the appliance ensure the glass is fully dried.
GB
If the rope seal has absorbed excess cleaning agent it is advisable
to replace the rope as soon as possible to preserve the printed
finish of the glass.
CHIMNEY SWEEPING
To maintain safe and efficient use of the appliance, the chimney/
flue must be inspected and swept at least once a year by a
qualified chimney sweep.
If the appliance is used continuously throughout the year, or it is
used to burn wood, more frequent sweeping is recommended.
The best time to have the chimney swept is at the start of the
heating season.
The chimney, any connecting flue pipe and the appliance flue
ways, if incorporated, must be regularly cleaned.
Ensure adequate access for cleaning where it is not possible to
sweep through the chimney.
If the chimney is believed to have previously served an open fire
it must be swept a second time within a month of regular use after
installation.
CO ALARMS
Building regulations require that whenever a new or replacement
fixed solid fuel or wood/biomass appliance is installed in a dwelling
a carbon monoxide alarm, complying with BS EN50291, must be
fitted in the same room as the appliance.
HETAS recommend the unit is permanently fixed in accordance
with the manufacturer's installation instructions or with the guidance
contained in Approved Document J where no other information is
available.
Provision of an alarm must not be considered a substitute for either
installing the appliance correctly or ensuring regular servicing and
maintenance of the appliance and chimney system.
SEASONAL USE
Clean and service the appliance if not used during the warmer
months, as detailed in the Maintenance and Servicing section.
Set the air controls to 50% to keep the appliance ventilated and
stop the build-up of any moisture inside.
Before re-lighting the appliance:
— Remove the baffles.
— Clear any debris that may have accumulated.
— Check the flue is clear of any blockages.
8
GB
SERVICING AND SUPPORT
Servicing and Support
To keep your appliance looking and performing at its best, it
must be serviced annually. This service must be undertaken by
a suitably qualified individual and your retailer can organise this
for you. Alternatively, Stovax offer a manufacturers premium
service with our friendly team of qualified engineers which can
be booked at www.stovax.com/support
OPTIONAL EXTRAS
OUTDOOR AIR KIT
This appliance can be fitted with an optional kit to help bring air
directly into the appliance from outside. The For installation and
operating procedures you must refer to the instructions supplied
with the Outside Air kit.
WARM AIR DUCTING KIT
This appliance can be fitted with an optional Warm Air Ducting kit
to help circulate warm air to other room in the house.
This operation may require additional ventilation in order to
comply with building regulations and a qualified installer should be
consulted before fitting.
The Ducting kit must be fitted at the time of installation. For
installation and operating procedures you must refer to the
instructions supplied with the Warm Air Ducting kit.
9
GB
TROUBLESHOOTING
Operation - Difficulty starting and maintaining a fire
Ensure the wood used is less than 20% moisture.
Warm the flue through the stove using a blowtorch or some
newspaper.
Ensure all air controls are being operated correctly.
Open a nearby window to test the airflow in the room.
Make sure the airways and flue are swept and in good
condition. Any full or partial blockage will effect the
performance of the appliance.
Re-read the lighting instructions and ensure the correct
procedure is followed including fuel amounts.
Glass Blackening
When burning wood and solid fuel there will always be some
discolouration of the glass. However excessive build can be
caused by:
Wood will a moisture content of greater than 20% will have
poor combustion and smoke, giving off tar and creosote.
Low combustion temperature. This will not create sufficient
flue draft leading to poor combustion and a fire that produces
more smoke.
Incorrect fuelling/refuelling leading to a poor fire or one that
touches the glass.
Excessive smell of Smoke
Weather conditions can result in wind blowing down the
chimney when coming from certain directions.
Door opened when lots of flames remained in the firebox.
Parts have become discoloured
To allow the appliance to settle, and fixing glues and paint to
fully cure, operate the appliance at a low temperature for first
few days.
Do not touch the paint during the first period of use.
During this time the appliance may give off some unpleasant
odours. Keep the room well ventilated to avoid a build-up of
fumes.
Please be aware that, during use, paint and rope seals may
discolour. This is normal.
Warranty Issues - for full warranty terms and conditions see the
booklet supplied with your appliance.
Should you experience problems with your Stove or Fireplace, any
claim must be submitted first to the Expert Retailer from whom the
product was purchased. Your Expert Retailer will either be able to
offer immediate assistance or having visited you make contact with
Stovax on your behalf. For a Service call to be arranged Stovax
will require proof of registration, commissioning documents and
service history if applicable (Service history required for all product
over 12-months old). Any Warranty claim without the required
information will be referred back to your Expert Retailer from whom
you purchased it.
Due to continual technical improvements please check online or with your Stovax retailer for the most up to date parts lists.
Only use Genuine Stovax spares when servicing your appliance.
All of our essential spare parts and consumable items are available to purchase from our webshop at www.stovaxspares.com.
10
THE CLEAN AIR ACT 1993 AND SMOKE CONTROL AREAS
The Clean Air Act 1993 and Smoke Control Areas
Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area.
It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed boiler if located in a designated
smoke control area. It is also an offence to acquire an “unauthorised fuel” for use within a smoke control area unless it is used
in an “exempt” appliance (“exempted” from the controls which generally apply in the smoke control area).
In England appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to
sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation Act 2015. Similarly in Scotland appliances are
exempted by publication on a list by Scottish Ministers under section 50 of the Regulatory Reform (Scotland) Act 2014.
In Wales and Northern Ireland these are authorised by regulations made by Welsh Ministers and by the Department of the
Environment respectively.
Further information on the requirements of the Clean Air Act can be found here at:
https://www.gov.uk/smoke-control-area-rules
Refuelling to a low fire bed
If there is insufficient burning material in the firebed to light a new fuel charge, excessive smoke emission can occur. Refuelling
must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite in a reasonable
period. If there are too few embers in the fire bed, add suitable kindling to prevent excessive smoke.
Fuel Overloading
The maximum amount of fuel specified in this manual should not be exceeded, overloading can cause excess smoke.
Operation with the door left open
Operation with the door open can cause excess smoke. The appliance must not be operated with the appliance door left open
except as directed in the instructions.
Air Controls left open
Warning: Do not operate the appliance with the Primary Air Control open for long periods of time as this could cause over-firing,
increased smoke emissions and may cause permanent damage.
CO Alarms
Building regulations require that whenever a new or replacement fixed solid fuel or wood/biomass appliance is installed in a
dwelling a carbon monoxide alarm, complying with BS EN50291, must be fitted in the same room as the appliance. Further
guidance on the installation of the carbon monoxide alarm is available in the latest edition of BS EN50292 and from the alarm
manufacturer's instructions.
Provision of an alarm must not be considered a substitute for either installing the appliance correctly or ensuring regular
servicing and maintenance of the appliance and chimney system.
The following Studio appliances (Model No: 326-140/ 726-006/ RVST-1EU/ RVST-2EU/ RVST-3EU/ RVFST-1EU/ RVFST-2EU/ RVFST-
3EU) have been recommended as suitable for use in smoke control areas when burning wood logs. These appliances (Model
No: 326-140/ 726-006/ RVST-1EU/ RVST-2EU/ RVST-3EU/ RVFST-1EU/ RVFST-2EU/ RVFST-3EU) are fitted with the appropriate
permanent stop for the model (supplied by Stovax) to prevent full closure of the secondary air inlet slots.
This appliance is suitable for use in a Smoke Control Area when burning wood and following the
instructions for use specified in this manual but ONLY if the Smoke Control stop has been enabled.
The Studio has been independently tested to PD6434 making it exempt from the controls that generally
apply in Smoke Control Areas.
THE SMOKE CONTROL FACILITY IS SUPPLIED DISABLED AND MUST THEREFORE BE MODIFIED
BEFORE INSTALLATION IN ORDER FOR THE APPLIANCE TO MEET THE REQUIREMENTS OF A
SMOKE CONTROL AREA AND MUST BE OPERATED CORRECTLY TO MINIMISE THE AMOUNT OF
SMOKE PRODUCED.
Any modifications to the setting should only be done by a suitably qualified installer and must be done at
the time of installation.
UK SMOKE CONTROL AREAS
GB
11
LEGAL REQUIREMENTS
Before installation and/or use of this appliance please read these
instructions carefully to ensure that all requirements are fully
understood.
The appliance must be fitted by a registered installer, or
approved by your local building control officer.
It is very important to understand the requirements of the
national Building Regulations
and standards
,
along with any local
regulations and working practices that may apply. Should any
conflict occur between these instructions and these regulations
then the regulations must apply.
Your local Building Control Office can advise regarding the
requirements of the regulations.
HEALTH AND SAFETY PRECAUTIONS
Works must be carried out with care to meet the requirements of
Health and Safety
and comply with the Health and Safety rules,
and any new regulations introduced during the lifetime of these
instructions. Particular attention should be drawn to:
Handling: The appliance is heavy. Adequate facilities must be
available for loading, unloading and on site handling.
Fire Cement: Some fire cement is caustic and must not come
into contact with the skin. Protective gloves must be worn.
Wash hands thoroughly with plenty of water after contact with
skin.
Asbestos: This appliance contains no asbestos. If there is
the possibility of disturbing any asbestos in the course of
installation seek specialist guidance and use appropriate
equipment.
Metal Parts: Take care when installing or servicing the stove to
avoid personal injury.
A faulty installation can cause danger to the inhabitants and
structure of the building.
For users of this appliance:
Your building insurance company may require you to inform them
that a new heating appliance has been installed on your property.
Check that your cover is still valid after installing the appliance.
Combustion Air Supply:
This appliance requires a constant supply of air to maintain proper
combustion and effective flue performance.
An inadequate air supply can result in poor combustion and smoke
entering the room which is potentially dangerous.
This supply of air can come from either:
— Purpose provided ventilation.
— Some Stovax appliances can also be fitted with an
optional outdoor air kit which allows air to be drawn in
from the outside.
The amount of air required must comply with local building
regulations and the rules in force.
If spillage is detected during commissioning then there may be
insufficient natural ventilation and an additional air supply will be
necessary.
Permanent air vents should be non-adjustable and positioned
where they are unlikely to be become blocked.
Extractor fans or cooker hoods must not be placed in the same
room or space as this can cause the appliance to emit fumes into
the room.
Aerosol Sprays
Do not use an aerosol spray on or near the appliance when it
is alight.
Combustible Materials in the home
Do not place photographs, TV’s, paintings, porcelain or other
combustible items on the wall or near the appliance. Exposure
to hot temperatures will cause damage. Do not place furniture
or other items such as drying clothing closer than 1m from the
front of this appliance.
WARNING: Extra fuel should not be stored on or next to the
appliance. Only keep enough fuel for immediate use nearby
and never leave the appliance unattended for long periods with
any combustible material in close proximity.
HEARTHS
The appliance must stand on a non-combustible constructional
hearth in accordance with Approved Document J.
As this appliance can be installed in an elevated setting it is
recommended to increase the 225mm hearth depth to safely
contain any falling logs or embers. The higher the appliance is
installed the deeper the hearth should be to protect the floor.
The building must have a suitable load-bearing capacity for the
hearth and appliance. Consult a structural engineer for advice
before proceeding.
Some houses are built using a timber frame construction with high
levels of thermal insulation. Isolate the appliance from combustible
materials, and provide sufficient ventilation to maintain the heating
efficiency.
COMMISSIONING AND HANDOVER
Ensure all parts are fitted in accordance with the instructions.
On completion of the installation allow a suitable period of time for
any fire cement and mortar to dry out, before lighting the stove.
Once the appliance is operating check all seals for soundness and
check that the flue is functioning correctly and that all products
of combustion are vented safely to atmosphere via the chimney
terminal.
On completion of the installation and commissioning ensure
that the operating instructions for the appliance are left with the
customer. Ensure to advise the customer on the correct usage and
warn them to use only the recommended fuel for the appliance.
Advise the user what to do should smoke or fumes be emitted from
the appliance.
The customer should be warned to use a fireguard to BS
8423:2002 in the presence of children, aged and/or infirm persons.
GB
12
FLUE AND CHIMNEY
The flue or chimney system must be in good condition.
It must be inspected by a competent person and passed for use
with the appliance before installation.
Products of combustion entering the room can cause serious
health risks.
The following must be checked:
The construction of the masonry chimneys, flue block chimneys
and connecting flue pipe system must meet the requirements of
the Building Regulations.
A flexible flue liner system can be used if certified for use with
solid fuel systems and installation complies with manufacturer’s
instructions and Building Regulations.
The flue liner must be replaced when an appliance is replaced,
unless proven to be recently installed and in good condition.
If it is necessary to fit a register plate it must conform to the
Building Regulations.
The minimum height of the flue or chimney must be 4.5m from
the hearth to the top of the flue, with no horizontal sections and
a maximum of 4 bends. Bends must have angles of less than
45 degrees from the vertical.
— There should be at least 600mm of vertical flue pipe above the
appliance before any bends are introduced.
Ensure the connecting flue pipe is kept a suitable distance
from any combustible material and does not form part of the
supporting structure of the building.
— The installer must ensure the flue pipe diameter is not less than
the diameter of the outlet of the appliance and does not narrow
to less than the size of the outlet at any point in the system.
Make provision to remove the appliance without the need to
dismantle the chimney.
Any existing flue must be confirmed as suitable for the new
intended use as defined in the Building Regulations.
The flue or chimney systems must be inspected and swept
to confirm the system is structurally sound and free from
obstructions.
If the chimney is believed to have previously served an open fire
it must be swept a second time within a month of regular use
after installation to clear any soot falls that may have occurred
due to difference in combustion levels.
The flue exit from the building must comply with local building
control rules.
— Chimney heights and/or separations may need to be increased
in particular cases where wind exposure, surrounding tall
buildings, high trees or high ground could have adverse effects
on flue draught.
Do not connect or share the flue or chimney system with
another heating appliance.
Do not connect to systems containing large voids or spaces over
230mm square.
Suitable access must be provided to enable the collection and
removal of debris.
The flue must be swept and inspected when the appliance is
installed.
Flue Draught
The flue draught must be checked with all windows and doors
closed and any extraction fans in this, or adjoining rooms, running
at maximum speed.
GB
13
GB
PRODUCT MATERIAL INFORMATION
The following substances, preparations or components should be disposed of or recovered separately from other WEEE in compliance
with Article 4 of EU Council Directive 75/442/EEC.
Metal
Steel
Can be taken to a local recycling centre for reuse to reduce waste going to landll.
Cast iron
Glass Can be taken to a local recycling centre for reuse to reduce waste going to landll.
Vermiculite linings
Non hazardous material. Vermiculite can be crushed up and used for plant bedding and ash used for
composting or disposed of at a local recycling centre for reuse to reduce waste going to landll.
Rope seals
Rope seals are made from Refractory Ceramic Fibre (RCF), a material which is commonly used for
this application. Protective clothing is not required when handling these articles, but it is recommended
to follow normal hygiene rules of not smoking, eating or drinking in the work area and always wash
hands before eating or drinking. When servicing the appliance it is recommended that the replaced
items are not broken up, but are sealed within heavy duty polythene bags and labelled as RCF waste.
RCF waste is classed as stable, non-reactive hazardous waste and may be disposed of at a licensed
landll site.
Electrical
components
(Fan kits etc
if applicable)
Dispose of at a local recycling centre in accordance with the WEEE directive.
14
GÉNÉRALITÉS
IMPORTANT
L’EXTÉRIEUR, LA FACE AVANT ET LA VITRE DE CET
APPAREIL, DEVIENNENT TRÈS CHAUDS PENDANT SON
UTILISATION ET TOUT CONTACT PEUT ÊTRE LA CAUSE
DE BLESSURES GRAVES ET DE BRÛLURES. IL EST DONC
FORTEMENT RECOMMANDÉ D’UTILISER UN PAR-FEU EN
PRÉSENCE DE JEUNES ENFANTS, DE PERSONNES ÂGÉES
OU HANDICAPÉES.
Ne pas essayer d’incinérer des déchets dans ce poêle.
Lire attentivement ces instructions avant d’installer et d’utiliser ce
poêle. Conserver ce document en lieu sûr.
Les instructions seront requises pour future référence et pour la
maintenance du poêle.
Avant de procéder à l’installation ou d’utiliser cet appareil, veuillez
lire l’ensemble de ces instructions avec attention de manière à bien
comprendre leurs exigences.
Cet appareil doit être installé par un installateur agréé, ou
approuvé par le bureau de contrôle de construction le plus
proche.
Toutes les réglementations locales, y compris celles qui se
rapportent aux normes nationales et européennes doivent être
respectées pendant l’installation du poêle.
Cet appareil ne doit être utilisé que pour le chauffage domestique et
conformément à ces instructions d’utilisation.
Ne brûler que des combustibles approuvés. Ne pas utiliser de
combustibles liquides ou incinérer des déchets.
Ne pas poser de photos, un écran de télévision, des tableaux, des
articles en porcelaine ou autres matériaux combustibles sur le mur
ou près de l'appareil. Leur exposition à une haute température peut
les endommager.
Ne pas placer de meubles ou d’autres appareils ménagers comme
un sèche-linge à moins de 1 m du devant de cet appareil.
AVERTISSEMENT : Toute réserve de combustible ne doit pas
être stockée sur ou à proximité de l'appareil. Veuillez ne conserver
qu'une quantité de combustible suffisante pour un usage immédiat
à proximité et ne laissez jamais l'appareil sans surveillance pendant
une période prolongée lorsqu'il y a du combustible à proximité.
Des ventilateurs et des hottes d'extraction peuvent être installés
dans la même pièce que l'appareil fournit sous réserve que soit:
– La hotte est à recyclage.
– La hotte n'est pas susceptible de provoquer une dépression
suffisante pour entrainer une inversion du tirage du conduit - prise
en compte dans le dimensionnement du conduit de fumée selon la
NF EN 13384-1.
– Soit l'appareil a une arrivée d'air étanche depuis l'extérieur et
fonctionne exclusivement avec les portes fermées.
Ne pas obstruer le dispositif de ventilation intérieur ou extérieur afin
d’assurer le bon fonctionnement du poêle en toute sécurité.
Ne pas modifier cet appareil sans autorisation.
La cheminée doit être ramonée au moins deux fois par an dont 1
fois pendant la période d’utilisation.
Ne pas connecter ou partager le même conduit ou la même
cheminée avec un autre appareil de chauffage.
AVERTISSEMENT
Cet appareil de chauffage n’émettra pas de fumée
dans la pièce s’il est correctement installé, utilisé
et entretenu.
De la fumée peut s’échapper occasionnellement
pendant le vidage du bac à cendres ou lors du
remplissage de combustible.
L’émission persistante de fumée est
potentiellement dangereuse et elle ne doit pas être
tolérée.
Si l’émission de fumée persiste :
• Ouvrir les portes et les fenêtres pour ventiler la
pièce.
• Quitter la pièce.
• Laisser brûler complètement le combustible ou
vider le foyer en prenant toutes les précautions
nécessaires.
Vérifier que la cheminée n’est pas obstruée et la
ramoner le cas échéant.
Ne pas tenter de rallumer le poêle avant d’avoir
identifié la cause de l’émission de fumée et
remédié à ce dysfonctionnement.
• Demander au besoin conseil à un expert.
• Tous les appareils à tirage naturel peuvent être
affectés par des conditions atmosphériques
temporaires capables de repousser la fumée dans
la maison. C'est la raison pour laquelle Stovax
recommande la mise en place d'un détecteur de
monoxyde de carbone dans la même pièce où est
installé l'appareil. La présence d’une alarme ne doit
pas être considérée comme un substitut pour un
entretien et une maintenance régulière de l’appareil
et de la cheminée.
SI L'ALARME RETENTIT, SUIVRE LES
INSTRUCTIONS FOURNIES CI-DESSUS.
NUMÉRO DE SÉRIE
Ce numéro est requis pour commander des pièces de
rechange ou faire une demande de dédommagement sous
garantie.
La Plaque du Constructeur se trouve :
FR
La plaque du constructeur du
Studio 3 n'est accessible que
lorsque la porte est fermée.
Plaque du
Constructeur
15
FR
OUVERT
FERMÉ
STUDIO 3
MISE EN ROUTE
OUVERTURE DE LA PORTE - STUDIO 500,1 & 2
Les produits Stovax ont été conçus pour offrir un chauffage secondaire à votre maison et
minimiser les émissions atmosphériques provenant du chauffage au bois.
Mais cela exige la technique d'allumage suivante et un combustible de bonne qualité pour
optimiser le démarrage du poêle et amener le conduit à la température de fonctionnement.
Stovax vous recommande de vous familiariser avec le fonctionnement du feu, le bon type de
combustible sec et les méthodes d’empilement pour obtenir les meilleures performances de votre
appareil.
L’effet flammes propres est obtenu avec les bonnes conditions de tirage de conduit et la qualité
du combustible utilisé. L’expérience permettra de définir les réglages favoris et assurera une
consommation optimale de combustible.
FLAMMES PROPRES ET VOTRE POÊLE
CONTRÔLES DE L'AIR
Commande d’air de nettoyage
Air
secondaire
réglé en
usine
OUVERT
OUVERT
FERMÉ
Commande d’air primaire
FERMÉ
FERMÉ
OUVERT
• Définir les réglages d’air à 50 % pour maintenir l’appareil aéré et arrêter
l’accumulation d’humidité à l'intérieur lorsqu’il n’est pas utilisé pendant de longues
périodes.
• S’il reste un combustible en train de brûler dans le foyer, ne pas fermer
complètement les réglages d’air sauf si un feu de cheminée est en cours
• Fermer les réglages pendant la combustion provoquera une mauvaise combustion
et peut entraîner l’accumulation de gaz qui pourraient s’enflammer dangereusement.
• Toujours laisser suffisamment d’air pénétrer dans l'appareil pour maintenir une
flamme dans le foyer.
• S’il est nécessaire d’arrêter l’appareil, faire fonctionner sur un paramètre élevé
jusqu’à ce que tout le combustible ait brûlé avant de fermer les réglages d’air.
16
FR
ALLUMAGE
Air de nettoyage : Grand Ouvert
Air primaire: Grand Ouvert
Pour créer une pile ouverte à allumer du haut en bas :
Disposer parallèlement deux bûches de taille moyenne au fond
du foyer.
Poser deux bûches plus petites par-dessus, parallèles entre
elles mais perpendiculaires aux deux premières.
Continuer à bâtir la pile avec des bûches plus petites et
déposer un allume-feu au centre.
Terminer la pile en ajoutant deux dernières bûches et déposer
des allume-feux dessus. Ajouter un peu de petit bois si on le
souhaite..
1
2
3
4
REMARQUE : Le petit bois est indispensable pour que le foyer
atteigne rapidement la bonne température de service. Un mauvais
démarrage peut produire une fumée excessive et la sortie du feu
lorsque la porte est fermée.
Un bon feu demande beaucoup de petit bois pour que le poêle soit
chaud et chauffer la cheminée pour une meilleure performance de
combustion
Petit bois :
Bois finement coupé
Longueur 250 mm
Diamètre : 20 mm
Poids pour démarrage: 2,0 kg (8 à 12 pièces finement coupées
environ)
Fermez immédiatement la porte pour éviter que des produits de
combustion en excès ne pénètrent dans la pièce.
Assurez-vous d'utiliser des bûches fendues et non des
morceaux de bois entiers. Si le poêle contient trop de
combustible, l'appareil atteindra des températures supérieures
à la température prévue.
Ceci peut endommager les pièces à l'intérieur du poêle.
Chargements suggérés:
Studio 500 - 2/3 bûches d’un diamètre ne dépassant pas 80mm
Studio 1 & 2 - 3/4 bûches d’un diamètre ne dépassant pas 127mm
Studio 3 - 4/5 bûches d’un diamètre ne dépassant pas 127mm
Fermer la porte et suivre les instructions de fonctionnement de
l'appareil.
Ne pas laisser la porte ouverte à cause de l’excès de tirage qui
peut entraîner une surchauffe et endommager l’appareil.
AVERTISSEMENT: NE PAS LE FAIRE FONCTIONNER AVEC
LA PORTE ENTROUVERTE, SAUF POUR LA PÉRIODE
D’ALLUMAGE INITIALE, CAR CELA RISQUE DE PROVOQUER
UNE SURCHAUFFE ET D’ENDOMMAGER L’APPAREIL.
UTILISATION DE L’APPAREIL POUR LA PREMIÈRE
FOIS
Pour permettre au poêle de se stabiliser et aux
colles et peintures de durcir, utiliser le poêle à une
puissance modérée pendant les premiers jours.
Ne pas toucher la peinture pendant la période initiale
d’utilisation.
Pendant cette période, la surface de l’appareil émet
des odeurs déplaisantes. S’assurer que la pièce est
bien ventilée pour éviter l’accumulation de vapeurs
Veuillez noter que les joints d’étanchéité peuvent se
décolorer durant l’utilisation. Ceci est normal.
17
UTILISATION DE L’APPAREIL
FEU DE BOIS
Fermer la commande d’air primaire et utiliser la commande d’air
de nettoyage pour contrôler la vitesse de combustion lorsque la
température
Air de nettoyage: Air de nettoyage: Régler le Régler le
taux de combustiontaux de combustion
Air primaire: FerméAir primaire: Fermé
MaxMax
MinMin
Le bois brûle mieux sur un lit de braises (environ 25 mm=
d'épaisseur).
Ne faites pas brûler de grandes quantités de combustible de façon
prolongée lorsque la commande Airwash est fermée. Ceci réduit
l'effet de nettoyage du verre de la fonction Airwash et entraîne
l'accumulation de goudron et de créosote dans l'appareil et dans le
conduit de cheminée.
Pour réduire la formation de goudron et de créosote, faire
fonctionner l'appareil à haute température pendant une courte
période au cours de son fonctionnement.
AVERTISSEMENT : NE PAS FAIRE FONCTIONNER
L'APPAREIL AVEC LA COMMANDE DE CIRCULATION D'AIR
PRIMAIRE (PRIMARY) DE FAÇON PROLONGÉE CAR CECI
PEUT ENTRAÎNER UNE SURCHAUFFE ET ENDOMMAGER
L'APPAREIL DE FAÇON PERMANENTE.
L’expérience permet de régler le feu à sa convenance personnelle.
RAVITAILLEMENT
Ouvrir les commandes d'air primaire et du système Airwash à fond.
Ratisser les braises pour les répartir uniformément sur le
foyer et obtenir un foyer rougeoyant. Si le foyer est faible,
ajouter un peu de petit bois pour aider à relancer le feu.
Ne pas ravitailler si une grande quantité de flammes est
présente dans le poêle car de la fumée ou des flammes
pourraient s'échapper dans la pièce.
Fermer les portes immédiatement après avoir effectué le
ravitaillement.
Ces appareils sont larges et les bûches doivent être déposées en
une seule couche en laissant de l'espace entre elles.
Ne pas empiler les bûches les unes sur les autres car ceci
pourrait affecter l'efficacité de l'appareil.
NE PAS SURCHARGER L'APPAREIL, CAR UNE SURCHARGE
DE COMBUSTIBLE PEUT CONDUIRE À UNE SURCHAUFFE DE
L'APPAREIL.
Après le ravitaillement :
Faire brûler les nouvelles bûches à haute puissance pendant
quelques minutes avant de fermer la commande d'air primaire.
Régler le taux de combustion à l'aide de la commande
Airwash.
Ne pas fermer les commandes d'air tant que le feu n'est pas
bien établi.
Ne pas brûler de grandes quantités de combustible avec la
commande Airwash fermée sur de longues périodes. Ceci réduit
l'effet autonettoyant du verre, ce qui conduit à une accumulation de
goudron et de créosote dans l'appareil et le système d'évacuation
et à la production d'une quantité excessive de fumée.
Lors de l'utilisation de l'appareil, rajouter du combustible
souvent et en petites quantités de façon à ce qu'il brûle
proprement et efficacement.
Un poêle propre et lumineux indique que l'appareil brûle bien.
Ne pas brûler de combustible en continu avec la porte
ouverte.
COMBUSTIBLES RECOMMANDÉS
Bûches de bois :
Ne brûler que du bois bien séché dont le taux d’humidité est
inférieur à 20%. Laisser sécher le bois coupé à la longueur
pendant 18 à 24 mois avant de l'utiliser.
Longueur des bûches
L'appareil Longueur des bûchesLongueur des bûches
Studio 500 Jusqu'à 250mm
Studio 1 250mm - 300mm
Studio 2 250mm - 400mm
Studio 3 250mm - 500mm
Le bois de mauvaise qualité :
A un faible rendement de combustion
— Produit de la condensation nuisible
Réduit l’efficacité de l’air de nettoyage et la durée de vie
du poêle
Ne pas brûler de bois de construction, de bois peint ou
imprégné de produit / traité, ni de produits manufacturés en
bois ou des planches de palettes.
Consommation de combustible.
Testée à la puissance nominale conforme à la norme EN 13229:
2001 pour une utilisation intermittente:
DESCRIPTION
CONSOMMATION DE
COMBUSTIBLE
KG/HOUR - BOIS
Studio 500
1.62
Studio 1
1.5
Studio 2 2.3
Studio 3 3.4
FR
18
Un certain nombre de facteurs peuvent affecter la performance du
poêle. Voir la section dépannage pour les détails.
CHOIX DU COMBUSTIBLE :
Tous les types de bois peuvent être utilisés en guise de
combustible dans l’appareil. Les différents types de bois ont des
densités différentes : plus la densité est élevée, plus grande est la
valeur énergétique.
Le chêne, le hêtre et le bouleau possèdent les densités les plus
élevées.
La teneur en humidité correcte du bois de chauffage prêt à brûler
est inférieure à 20 %.
Si le bois est trop humide, il sera difficile à allumer, brûlera à grand-
peine, donnera très peu de chaleur et déposera du goudron dans
le conduit.
Cela pourrait conduire à un feu de cheminée. Il est donc important
de brûler du bois de chauffage bien séché.
Le bois sec donne plus de chaleur, évite de noircir la vitre de
l’appareil et dépose très peu de suie dans la cheminée ou le
conduit.
Plus de chaleur diffusée signifie moins de combustible consommé.
STOCKAGE DU BOIS :
Pour obtenir du bois bien sec, le couper en hiver et le stocker sous
un toit avec beaucoup d’espace pour la circulation d'air.
Ne pas couvrir entièrement, laisser un espace pour que l’air puisse
passer au-dessus du bois et ne pas sceller.
Transporter le bois à utiliser à l’intérieur et le stocker quelques jours
avant de le brûler pour que l’humidité ait suffisamment diminué.
Ne pas brûler de bois de construction, de bois
peint ou imprégné de produit / traité, ni de produits
manufacturés en bois ou des planches de palettes.
ENLÈVEMENT DES CENDRES
Le bois brûle mieux sur un lit de cendres. Les armatures
surélevées sur la grille donnent une bonne indication de la
profondeur idéale.
Ne pas laisser les cendres s’accumuler, car cela risque de
provoquer des dommages et d’affecter sérieusement les
performances de l’appareil.
Enlever les cendres à l’aide d'un aspirateur à cendre (disponible
auprès de Stovax). Faire attention de ne pas endommager
le revêtement en céramique de l'appareil. Ne pas utiliser de
tisonniers pointus.
Faire attention lors de l'enlèvement des cendres - elles peuvent
être chaudes longtemps après l'utilisation.
Déposer les cendres avec précaution dans le collecteur de cendres
Stovax.
Ne pas vider les cendres brûlantes dans une poubelle en
plastique ou tout autre matériau combustible.
COMBUSTION EXCESSIVE
Ne pas charger le insert excessivement en combustible ou laisser
le feu brûler à sa puissance maximum pendant de longues périodes
au risque de surchauffer le poêle.
NE PAS FAIRE FONCTIONNER L’APPAREIL PENDANT
DE LONGUES PÉRIODES DE TEMPS EN LAISSANT LA
COMMANDE D’AIR PRIMAIRE OUVERTE AU RISQUE DE
PROVOQUER UNE SURCHAUFFE ET DES DOMMAGES
PERMANENTS.
Une combustion excessive peut provoquer des dommages
permanents de l’appareil et invalider la garantie du produit.
FEU DE CHEMINÉE
En cas de feu de cheminée:
— Fermer immédiatement toutes les commandes d’air.
— Évacuer le bâtiment.
Appeler les pompiers.
— Ne pas rentrer dans le bâtiment avant d’avoir été informé
qu’il n’y a plus de danger.
Ne pas rallumer le poêle après un feu de cheminée avant que:
a) Le poêle ait été inspecté par un installateur agréé et que ce
dernier confirme que son utilisation ne présente aucun danger.
b) Le conduit de fumée et la cheminée aient été inspectés et
ramonés par un technicien qualié, qui conrme que le système est
structurellement intact et qu’il n’y a aucune obstruction.
c) Les réparations requises soient effectuées. Utiliser
uniquement des pièces de rechange Stovax authentiques pour
garantir le bon rendement du poêle en toute sécurité.
FR
19
NETTOYAGE GÉNÉRAL
Nettoyer et inspecter l’appareil régulièrement, particulièrement en
périodes d'utilisation intensive. Le nettoyage régulier et la bonne
maintenance du poêle garantissent des années de service en toute
sécurité.
Laisser le poêle refroidir complètement pour éviter tous
risques de brûlure.
Nettoyer le poêle régulièrement en fonction de l’intensité
d’utilisation.
Enlever les cendres entièrement.
Vérifier que les éléments internes ne sont pas endommagés -
grilles, briques, déflecteurs - et qu’il n’y a pas d’accumulation
évidente de suie, de cendres ou de débris au-dessus du ou des
déflecteurs (ils se trouvent dans la partie supérieure du foyer).
Utiliser une lampe électrique le cas échéant.
En cas d'accumulation de débris au-dessus du ou des déflecteurs,
veuillez soit :
— Faire ramoner la cheminée.
— Enlever les déflecteur et dégager les débris.
Pour faire des retouches de peinture, une peinture pour retouches
en aérosol est disponible. Contactez votre détaillant Stovax
en mentionnant le numéro de série qui se trouve sur la che
signalétique de l'appareil.
Ne pas utiliser de nettoyant en aérosol près d’un poêle allumé.
NETTOYAGE DE LA VITRE
Pour éviter que la vitre se salisse, utiliser correctement le dispositif
d‘air de nettoyage et des combustibles de bonne qualité.
Il est parfois nécessaire de procéder à de plus amples opérations
de nettoyage.
Avant de procéder, laisser l'appareil refroidir complètement. Ne pas
nettoyer la vitre lorsqu'elle est chaude.
Sur les appareils dotés d'une vitre sérigraphiée ne pas utiliser
de nettoyants très alcalins ou acides tels car ces produits
de nettoyage agressifs sont conçus pour une utilisation sur
des vitres transparentes très sales. Sur les surfaces en verre
sérigraphié, utilisez le Nettoyant vitres Stovax (Stovax n°
4103). Sa formule est mieux adaptée à cette opération.
Avant d'appliquer tout produit de nettoyage, retirer la poussière et
la suie non incrustée à l'aide d'un chiffon humide.
Utiliser un nettoyant pour vitres approprié. Imprégner un chiffon de
liquide de nettoyage avant de l'appliquer sur la vitre.
Procéder soigneusement, sans appliquer de quantité excessive
de produit. Essayer d'éviter tout écoulement du produit : celui-ci
pourrait imprégner les joints d'étanchéité tout autour de la vitre.
La suie peut également contenir des particules acides ayant un
effet corrosif néfaste sur le verre sérigraphié.
Retirer les salissures à l'aide d'un chiffon humide puis essuyer
jusqu'à ce que la surface soit sèche.
Certains types de bois peuvent occasionner la formation de
résidus blancs sur le verre.
Dans ce cas, il est nécessaire de nettoyer ces résidus
au moins une fois par semaine au cours des périodes
d'utilisation intensive.
Si les agents nettoyants liquides recommandés ne
parviennent pas à éliminer ces résidus, Stovax propose un
tampon de nettoyage à sec qui contribuera à l'élimination des
taches incrustées.
Avant de rallumer l'appareil, s'assurer que la vitre est complètement
sèche.
Si le joint d'étanchéité a absorbé l'excédent de produit nettoyant,
il est conseillé de remplacer la corde dès que possible afin de
préserver l'aspect sérigraphié de la vitre.
RAMONAGE DE LA CHEMINÉE
Pour assurer un fonctionnement efficace du poêle en toute
sécurité, la cheminée et le conduit de fumée doivent être ramonés
au moins deux fois par an par un technicien qualifié.
Si l’appareil est utilisé constamment tout au long de l’année, ou s’il
est utilisé pour brûler du bois, il est recommandé de ramoner plus
souvent.
La meilleure période pour effectuer le ramonage est au début de la
saison froide.
La cheminée, le conduit de fumée et les branchements du conduit
sur le poêle le cas échéant, doivent être régulièrement nettoyés.
S’assurer de l’accessibilité adéquate des portes de nettoyage s’il
n’est pas possible de ramoner par la cheminée.
Si la cheminée a été auparavant utilisée avec un foyer ouvert, elle
doit être ramonée une deuxième fois après un mois d’utilisation
régulière suivant son installation.
DÉTECTEURS-AVERTISSEURS DE CO
Tous les appareils ouverts peuvent être affectés par des conditions
atmosphériques temporaires capables de repousser la fumée
dans la maison. Nous recommandons, lors de l’installation dans
une habitation d’un nouvel appareil ou d’un appareil de chauffage
de remplacement à bois ou multi-combustible qu’un détecteur-
avertisseur de CO soit installé dans la même pièce que l’appareil.
La présence d’une alarme ne doit pas être considérée comme
un substitut pour une bonne installation et un entretien et une
maintenance régulière de l’appareil et de la cheminée.
UTILISATION SAISONNIÈRE
Nettoyer et réviser le poêle s’il ne doit pas être utilisé pendant la
saison chaude, conformément aux instructions de la section
Maintenance et révision.
Ouvrir les commandes d’air à 50% pour assurer la ventilation de
’intérieur du poêle et éviter la formation de condensation.
Avant de rallumer le poêle :
Retirer les déflecteurs.
Enlever tous les débris qui auraient pu s’accumuler.
Vérifier que le conduit de fumée n’est pas obstrué.
FR
20
FR
EXTRAS EN OPTION
KIT D'APPROVISIONNEMENT
EN AIR EXTÉRIEUR
Cet appareil peut être équipé d'un kit optionnel aidant à
approvisionner l'appareil en air venant de l'extérieur. Pour connaître
les procédures d'installation et de fonctionnement, veuillez vous
reporter aux instructions fournies avec le kit d'approvisionnement
en air extérieur.
KIT D'AIR CHAUD
Cet appareil peut être équipé d'un kit optionnel d'air chaud qui aide
à faire circuler l'air vers d'autres pièces de la maison.
Afin de respecter les règlements en matière de construction,
il est possible qu'il faille installer un système de ventilation
supplémentaire.
La conduite doit être installée au moment de l'installation. Pour
connaître les procédures d'installation et de fonctionnement,
veuillez vous reporter aux instructions fournies avec le kit de
conduite d'air chaud.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

in altre lingue