Vemer Evo Din Manuale utente

Tipo
Manuale utente
Cronotermostato
Digitale
EVO.DIN
Manuale d’Uso
Manual User Digital Thermostat
.
- 31 -
Manual User Evo.din
English
Index
Safety warnings Page 31
Technical specifi cations Page 32
Control elements / Indications on display Page 34
Initial start-up / Reset Page 36
Clock setting Page 36
Programme setting Page 38
Temperature setting Page 40
Manual operation Page 41
Summer / Winter operation Page 42
ON-OFF command from the keyboard Page 43
Extension programme Page 44
Countdown programme Page 45
Telephone dialler Page 48
Advanced programming Page 49
Type of regulation Page 52
Display during operation Page 52
Reference standards Page 54
Winter programmes Page 55
Summer programmes Page 56
Dimension Page 57
Wiring diagrams Page 57
Dimension probe Page 58
Installation probe Page 58
SAFETY WARNINGS
During the installation and operation of the instrument, follow the
instructions below:
1) The instrument should be installed by qualifi ed personnel
2) Do not power or connect the instrument if any part of it is damaged
3) Follow the connection diagrams in this manual and on the instrument
The EVO.DIN is a panel mounted electronic command device in a standardised DIN
4 module container, which performs type 1B actions and is designed to operate in
areas with normal pollution degree.
Code Model
VE016200 EVO.DIN
- 32 -
Manual User Evo.din
English
TECHNICAL SPECIFICATIONS
Power supply: 230V (+10% -15%) 50-60Hz.
Autonomy: inside back-up capacitor to guarantee the operations in absence of
power for about 4 hours after 6 hours of continous power.
Consumption: 2,5VA (1,1W)
Inputs:
— Telephone dialler on / off command.
— Signal from remote temperature probe
Output:
— Bistable relay with 8 A AC (250 V AC) exchange contact.
4 settable temperatures:
antifreeze temperature level
lower temperature level
upper temperature level
T temperature that can be set in manual operation.
Pre-set in winter operation to:
= 06.0 °C [42.8 °F] fi eld of variation: 2.0 °C ÷ 15.0 °C [35.6 °F ÷ 59.0 °F]
= 16.0 °C [60.8 °F] fi eld of variation: 2.0 °C ÷ 20.0 °C [35.6 °F ÷ 68.0 °F]
= 20.0 °C [68.0 °F] fi eld of variation: 2.0 °C ÷ 37.7 °C [35.6 °F ÷ 99.9 °F]
T = 18.0 °C [64.4 °F] fi eld of variation: 2.0 °C ÷ 37.7 °C [35.6 °F ÷ 99.9 °F]
with condition: .
Pre-set in summer operation to:
= 23.0 °C [73.4 °F] fi eld of variation: 10.0 °C ÷ 37.7 °C [50.0 °F ÷ 99.9 °F]
= 26.0 °C [78.8 °F] fi eld of variation: 10.0 °C ÷ 37.7 °C [50.0 °F ÷ 99.9 °F]
= --.- °C [--.- °F] (system off)
TECHNICAL
S
PECIFICATION
S
- 33 -
Manual User Evo.din
English
T = 25.0 °C [77.0 °F] fi eld of variation: 2.0 °C ÷ 37.7 °C [35.6 °F ÷ 99.9 °F]
with the condition: .
Temperature regulation:
— ON-OFF (pre-set) with differential of 0.3 °C [0.5 °F].
proportional with differential at 1 °C (-0.6 +0.4) [1.8 °F (-1.1 +0.7)], base time 10
minutes.
Clock: weekly.
Daily resolution: 1 hour.
Temperature scale measured:
— 0.0 °C ÷ + 37.7 °C [32.0 °F ÷ 99.9 °F].
Temperature resolution: 0.1°C
Accuracy: ± 1 °C.
Measurement update: every 15 seconds.
Housing: 4 module DIN, gray RAL 7035
Protection degree: IP20 (IP41 on the front)
Remote probe (included): wall-mounted. Cable lengh: until 40 m (bipolar cable,
minimum section 1 mm2)
Operating temperature: 0 °C ÷ 50 °C [32.0 °F ÷ 140 °F].
Storage temperature: -10 °C ÷ 65 °C [20.0 °F ÷ 155 °F].
Relative humidity: 10% ÷ 90% non condensing
Terminal:
— 3 x 6 mm2 block for relay.
— 2 x 6 mm2 block for power supply
— 2 x 6 mm2 block for remote probe.
— 2 x 6 mm2 block for telephone dialler.
- 34 -
Manual User Evo.din
English
CONTROL ELEMENTS / INDICATIONS ON DISPLAY
Control elements
1) Key “ : winter operation (pre-set) or summer operation.
2) Key “ : manual operation (thermostat).
3) Key “ : increases the fi eld selected.
4) Key “ : confi rms the data entered.
5) Key “ : decreases the fi eld selected.
6) Key “ : clock setting.
7) Key “ : for the activation and deactivation of the normal operation of the
timed thermostat.
8) Key “ : programme setting.
9) Key “ : selects the comfort (winter) and saving (summer) temperatures.
10) Key “ : selects the saving (winter) and refrigeration (summer)
temperatures.
1
2
3
4
5
612
11
10
9
8
7
CONTROL ELEMENTS / INDICATIONS ON DISPLA
Y
- 35 -
Manual User Evo.din
English
11) Key “ : antifreeze temperature (winter) and system off (summer)
selection.
12) Key “ : used to extend the T2 (winter) or T1 (summer) programming up
to a maximum of 9 hours.
13) Key “R”: initialises the timed thermostat and cancels the programming set
from Monday at 00:00 and the default programmes (this key can
be reached from block 16.
15
16
17
18
19
21
20
14
22
Display indication
14) “Day” eld
15) “Clock” eld
16) “Countdown” or “extension” eld
17) “Activate cooling” eld
18) “Manual operation activated” eld
19) “Activate heating” eld
20) “Programme set” eld
21) “Alphanumeric” eld
22) “Ambient temperature” eld
- 36 -
Manual User Evo.din
English
INITIAL START-UP / RESET
Power the instrument.
All the segments of the display will be switched on and the relay will be activated for
3 seconds, after which the clock fi eld (15) will restart from 00:00 on Monday and
continue to fl ash until the clock is set.
If power fault is so long to cause the discharge of back-up capacitor, when power
turn again on, it can be necessary to press the reset key to restart correcly the
instrument.
Important
if the clock is not set the timed thermostat will not be regulated.
The regulation begins only after the time setting.
CLOCK SETTING
Press key . Field (21) will show the message “SEt”, the seconds will run throu-
gh in fi eld (22), and fi eld (15) will show the fl ashing digits of the minutes.
Press keys and to select the minutes.
Press to confi rm and start the fl ashing of the hour digits.
INITIAL
S
TART-UP / RE
S
E
T
CLOC
K
SE
TTIN
G
- 37 -
Manual User Evo.din
English
Press keys and to select the hour.
Press to confi rm and start the fl ashing of the day digits.
Press keys and to select the day.
Press to confi rm all the data and return to normal display mode.
- 38 -
Manual User Evo.din
English
On leaving this procedure, the clock will no longer fl ash. The ambient temperature
will be displayed in fi eld (22).
PROGRAMME SETTING
When the key is pressed, fi eld (14) will show the display for Monday. Field
(15) will show the programme selected fl ashing (P1 in the example), fi eld (21) will
show “Pro”, fi eld (20) will show the graphic trend for the programme and symbol
(17) or (19) will be activated, depending on the operating mode set (summer or
winter). If the programme highlighted is the correct one, the system will move to
the next day when is pressed.
If the programme highlighted is not the correct one for that day, it is possible
to search for another using the and keys, which modify the “Px” value
contained in fi eld (15). The change of programme also changes the content of fi eld
(20) in relation to the programme selected.
The programmes in default are set out at the end of this manual.
P
ROGRAMME SETTING
- 39 -
Manual User Evo.din
English
If no programme satisfi es the user’s requirements, select any programme and press
again. At this point the segment of fi eld (20) that refers to the fi rst hour
(hour 0) will fl ash and fi eld (22) will show the message “00h”, corresponding to
the programming hour fl ashing in the graphic fi eld.
Keys , and can be used to modify the temperature selected for that
hour, and at the same time move to the following hour. The and keys are
used to move from one hour to another without modifying the temperature set.
When is to be displayed (no graphic symbol) a special fl ashing operation takes
place in the two segments of the hour selected.
Press to confi rm the modifi ed programme and return to the situation with
“Px” ashing in fi eld (15).
Press to confi rm the programme for that day and move on to the next day, and
so on until Sunday is reached, at which point the system returns
After selecting the correct programme, it is possible to move to the next day by
pressing .
5
- 40 -
Manual User Evo.din
English
to normal operation.
6
TEMPERATURE SETTING
1 2
3
In any operating mode, the message for the temperature under modifi cation
will appear in fi eld (15) when keys , and are pressed (for
“t0=”appears, for “t1=” and for “t2=”). The temperature value will
ash in fi eld (22).
Use keys and to change the value and sto confi rm the change and
return to normal operation.
The setting limits for these sets are shown in the technical specifi cations.
TEMPERATURE
S
ETTIN
G
- 41 -
Manual User Evo.din
English
MANUAL OPERATION
In automatic operation, the system performs like a normal thermostat with Tm
operating temperature when key is pressed.
The current hour remains in fi eld (15). Field (14) shows the current day.
The “SEt” message appears in fi eld (21) cThe symbol (18) appears.
Field (20) disappears. In fi eld (22) the manual temperature value fl ashes.
Use keys and to change the value from 2.0 °C [35.6 °F] to 37.7 °C [99.9 °F]
.
When is pressed, or 20 after the last operation, the ambient temperature will
reappear in fi eld (22). It is possible to check the temperature set at any time by
pressing key or once.
If either of these keys is pressed a second time, it is possible to change the
temperature setting.
It is possible to move from the manual to the automatic programme by simply
pressing the key again.
1
2
3
M
ANUAL OPERATION
- 42 -
Manual User Evo.din
English
SUMMER / WINTER OPERATION
To move from winter to summer operation or vice versa, press key (1).
Field (21) will show the message “SEt”.
Field (15) will show the message “boil” (or “Cool”).
A fl ashing (or ) symbol will appear.
Use keys and to select one of the two operating modes.
The programme moves to the operating mode require when is pressed, or 20
seconds after the last operation.
The summer operating potential refl ects that of winter. This means that all the
parameters can be set by following the procedures in this instruction manual.
1
2
3
S
UMMER / WINTER OPERATIO
N
- 43 -
Manual User Evo.din
English
ON-OFF COMMAND FROM THE KEYBOARD
The On-Off command from the keyboard is used to activate or deactivate the normal
operation of the timed thermostat.
This command takes precedence over the telephone dialler command.
With the timed thermostat in automatic operating mode, for example,
the relay is set to off when key is pressed once.
When this key is pressed a second time, the instrument returns to the previous
status, which is automatic operation in this example.
The relay is not switched on or off immediately, but at the end of the minute that
follows the command.
£{Ç£ä£Î£È£
ÓÓ
1
2
3
N-
MMAND
R
M
H
K
YB
ARD
- 44 -
Manual User Evo.din
English
EXTENSION PROGRAMME
With the extension programme, it is possible to keep the temperature T2 in winter
operation (comfort) or the temperature T1 in summer operation (refrigeration) for
a time period equivalent to the hours set.
This programme can only be activated in automatic operating mode.
To programme an extension, press the key .
The symbol will appear in fi eld (16). Field (21) will show the message “PrL”.
A fl ashing “0” followed by the letter “h” will appear in fi eld (22).
Use the and keys to adjust the extension up to 9 hours (the hour metering
also includes the one when the programming operation takes place).
When the hours are increased, the programming bar in fi eld (20) is also updated.
The programme begins when is pressed, or 20 seconds after the last operation.
1
2
3
EXTENSION PROGRAMME
- 45 -
Manual User Evo.din
English
The symbol remains active in fi eld (21).
The ambient temperature reading reappears in fi eld (22)
Leave this programme at the end of the metering operation to return to automatic
operation, or press key followed by , until the hours return to 0, then press
.
COUNTDOWN PROGRAMME
This programme is used to keep the timed thermostat in manual operation (or
off) for a certain number of hours or days, to return spontaneously to automatic
operating mode.
From automatic mode, press key or ) to move to manual mode (or off).
Press the key to set the countdown programme.
Field (14) disappear. The symbol appears in fi eld (16).
Field (21) shows the message “Cnt”. The temperature value Tm appears in fi eld
(22) (or in winter operating mode, and nothing in summer).
The countdown value appears in fi eld (15). This is initially 00:00 (day:hour),
adjustable up to 99 days: 23 hours using the keys and .
1
2
COU
NTD
O
WN PR
OG
RAMM
E
- 46 -
Manual User Evo.din
English
The timed thermostat will operate as a thermostat (or off) until the time set expires.
Field (15) contains the decreasing number of days and hours. Field (22) shows the
ambient temperature reading.
The symbol in fi eld (16) ashes.
The symbol appears in manual operating mode (or nothing when switched off).
If the system is in manual operating mode, the temperature Tm can be modifi ed
with keys or , followed by confi rmation with .
If the system is off, can be modifi ed by pressing key ,
After setting the countdown time, the programme can be started by pressing ,
or 20 seconds after the last operation.
3
4
A1
- 47 -
Manual User Evo.din
English
followed by and , and confi rming with .
Press the key a second time to re-enter the programming and modify the meter
parameters.
As well as waiting for the end of the metering operation, it is also possible to leave
this programme to return to automatic operation by holding down the key for
more than three seconds.
B1
B2
C1
- 48 -
Manual User Evo.din
English
TELEPHONE DIALLER
The x.Code Wave (for land lines) or x.Code GSM (mobile network) series starters
are used to control the timed thermostat ON/OFF switch remotely.
Start-up “ON” command: green light on x.Code GSM telephone starter or red
light off on x.Code Wave telephone starter.
In this condition, the timed thermostat goes to automatic running with the weekly
programme set.
Any “ON” commands received following this one will not alter the status.
“OFF” command: red light on x.Code GSM telephone starter or red light on with
the x.Code Wave telephone starter.
In this condition, the timed thermostat is switched off (but the temperature set can
be maintained manually with the key, to be used as temperature in winter).
Any “OFF” commands received following this one will not alter the status.
Code Model Description
VN782900 x.Code Wave Telephone starter
VN799300 x.Code GSM GSM telephone starter
Note: to operate as a starter, the timed thermostat has to be in
“automatic operating mode”.
Important:
if the timed thermostat has been set to Off from the keyboard, the dialler
is not enabled;
the telephone starter status is checked every 5 minutes.
TE
L
E
PH
O
N
E
DIALL
E
R
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Vemer Evo Din Manuale utente

Tipo
Manuale utente

in altre lingue