Ravelli HRV 250 Use and Maintenance Manual

Categoria
Stufe
Tipo
Use and Maintenance Manual

Questo manuale è adatto anche per

USE AND MAINTENANCE MANUAL
HYDRO
Handheld Touch
Radio Hydro
Use and maintenance manual Touch Radio Hydro
Pag.3
Rev.2 06/04/2021
Sommario
Preface........................................................................................................................................................................ 5
WARRANTY ..................................................................................................................................6
Certicate of warranty............................................................................................................................................... 6
Warranty conditions .................................................................................................................................................. 6
Registration of warranty ........................................................................................................................................... 6
Info and problems ..................................................................................................................................................... 6
GENERAL INFORMATION ........................................................................................................... 7
Supply and safe-keeping ......................................................................................................................................... 7
Language ................................................................................................................................................................... 7
Symbols used in the manual ................................................................................................................................... 7
SAFETY MEASURES .......................................................................................................................................... 7
General safety warnings .......................................................................................................................................... 7
Residual risks ........................................................................................................................................................... 8
DESCRIPTION OF THE STOVE ....................................................................................................9
Intended use ............................................................................................................................................................. 9
Reasonably foreseeable incorrect use ................................................................................................................... 9
Obligations and forbidden actions ....................................................................................................................... 10
Characteristics of the fuel ..................................................................................................................................... 11
Non-permitted fuels ................................................................................................................................................. 11
Automatic cleaning system .................................................................................................................................... 20
Recharge the fuel .................................................................................................................................................... 20
Doors opening ......................................................................................................................................................... 20
User training ............................................................................................................................................................ 20
Safety devices.......................................................................................................................................................... 21
SHIPPING AND INSTALLATION ...............................................................................................22
Safety warnings for transportation and installation ........................................................................................... 22
Set-ups for the smoke evacuation system ........................................................................................................... 23
Installation ............................................................................................................................................................... 24
CONNECTIONS .................................................................................................................................................. 27
Chimney connection .............................................................................................................................................. 27
Components ............................................................................................................................................................. 27
Stove-system connection ....................................................................................................................................... 27
Connection of external probe or thermostat ....................................................................................................... 28
Testing and commissioning .................................................................................................................................. 28
Electric scheme ....................................................................................................................................................... 29
Connections for hydraulic diagrams ..................................................................................................................... 30
PLUMBING SYSTEM CONNECTIONS .......................................................................................32
Installation advice ................................................................................................................................................... 32
Hydraulic diagrams ................................................................................................................................................. 33
System water characteristics ................................................................................................................................. 36
System water load ................................................................................................................................................... 36
CONTROLS AND USE .................................................................................................................37
Control panel description ....................................................................................................................................... 37
Handheld touch radio initialization ....................................................................................................................... 37
Description of the handheld set ............................................................................................................................. 38
PROCEDURES FOR USE ................................................................................................................................. 39
Checks prior to start-up ......................................................................................................................................... 39
Feed screw loading ................................................................................................................................................. 39
Failed ignition .......................................................................................................................................................... 39
Description of the display and temperature adjustment ..................................................................................... 40
Quick status display................................................................................................................................................ 41
Use and maintenance manual Touch Radio Hydro
Pag.4
Rev.2 06/04/2021
OPERATING PHASES OF THE APPLIANCE .............................................................................. 42
Sequence of ignition phases .................................................................................................................................. 42
Eco stop ................................................................................................................................................................... 42
Stand-by ................................................................................................................................................................... 42
Sanitary .................................................................................................................................................................... 42
Description of menu functions ............................................................................................................................... 42
Setting ...................................................................................................................................................................... 46
Anti-condensation system ...................................................................................................................................... 47
Stove phase general layout .................................................................................................................................... 48
MAINTENANCE .................................................................................................................................................. 53
Safety warnings for maintenance .......................................................................................................................... 53
Cleaning .................................................................................................................................................................. 53
Extraordinary maintenance .................................................................................................................................... 54
Failure cases ............................................................................................................................................................ 55
STORAGE AND DISPOSAL ............................................................................................................................. 58
Disposal ................................................................................................................................................................... 58
TROUBLESHOOTING .................................................................................................................58
The stove does not work ........................................................................................................................................ 58
Dicult lighting ....................................................................................................................................................... 58
Smoke leakage......................................................................................................................................................... 58
The glass gets dirty easily ...................................................................................................................................... 58
Downtime (end of season) ..................................................................................................................................... 58
Preface
Dear Customer, We would like to thank you for choosing one of our stoves.
We invite you to read this manual carefully, before starting installation and use, so that you are able to benefit from all of its character-
istics better and in full safety. It contains all necessary information for correct installation, start-up, operation, cleaning, maintenance,
etc.
Keep this manual in a suitable location, do not discard it without reading it.
Incorrect installation, maintenance and improper use of the product relieve the Manufacturer of all liability deriving from use of the
stove.
For further information and requirements contact your Ravelli-authorised Technical Assistance Centre.
All rights reserved. No part of this instructions manual can be reproduced or transmitted through any electronic or mechanical means,
including photocopies, recordings or any other storage system, for other purposes that are not exclusively use by the buyers staff,
without the express written consent of the Manufacturer.
Use and maintenance manual Touch Radio Hydro
Pag.6
Rev.2 06/04/2021
WARRANTY
Certicate of warranty
Ravelli thanks you for the trust granted with the purchase of one of its products and invites the purchaser to:
read the installation, use and maintenance instructions for the product;
read the warranty conditions contained below.
Warranty conditions
The warranty for the Customer is acknowledged by the Dealer under the terms of law.
The Dealer acknowledges the warranty only if the product has not been tampered with and only if it has been installed in accordance
with the Manufacturers instructions.
The limited warranty covers manufacturing material defects, as long as the product has not broken sue to an incorrect use, negli-
gence, incorrect connection, tampering, installation errors.
The warranty becomes null and void even if only one requirement in this manual is not complied with.
The following are not covered by warranty:
the combustion chamber refractory stones;
the door glass;
the gaskets;
the paint job;
the stainless steel or cast iron combustion grille;
the resistance;
the Majolica cladding;
the aesthetic parts;
any damages caused by unsuitable installation and/or use of the product and/or shortcomings on the part of the customer.
The use of poor quality pellet or any other unauthorised fuel may damage the product’s components, cause its warranty to be voided
and as a result eliminate the connected manufacturer liability.
It is therefore recommended to use good quality pellet that fulfils the requirements listed in the dedicated chapter.
All damages caused by transportation are not recognised, for this reason it is recommended to carefully check goods upon receipt,
immediately warning the reseller of any damage.
Registration of warranty
To activate the warranty, it is necessary to register the product on the Guarantee Portal on the website
www.ravelligroup.it, by entering your data and the purchase receipt.
Info and problems
Dealers authorised by Ravelli use a trained Technical Service Centre network to meet the Customer’s requirements. For any
information or request for assistance, please contact your Dealer or the Technical Service Centre.
Use and maintenance manual Touch Radio Hydro
Pag.7
Rev.2 06/04/2021
GENERAL INFORMATION
Supply and safe-keeping
The manual is supplied in printed format.
Keep this manual safe, with the stove, so that the user can consult it easily.
The manual is an integral part, for safety reasons, therefore:
it must be kept intact (in full). If it gets lost or ruined it is necessary to immediately ask for a new copy:
it must be kept with the stove until demolition (including relocation, sale, rental, lease, etc....).
The Manufacturer will not be held liable for improper use of the stove and/or damage caused by operations that are not set forth in
the technical documentation.
Language
The original manual was written in Italian.
Any translations into additional languages must be carried out based on the original instructions.
The Manufacturer is liable for the information contained in the original instructions; the translations into dierent languages cannot be
fully veried therefore if any inconsistency arises it will be necessary to follow the text in the original language or contact our Technical
Documentation Oce.
Symbols used in the manual
symbol denition
📌This symbol is used to identify particularly important information in the manual. This information also concerns the
safety of users involved in using the stove.
This symbol is used to identify important warnings for the safety of the user and/or the stove.
SAFETY MEASURES
General safety warnings
📌Read this instructions manual carefully before stove installation
and use. Failure to observe the instructions set forth herein
can void the warranty and/or cause damage to property and/
or people.
Stove installation, system verification, operation verification
and initial calibration must be carried out exclusively by qualified
and authorised staff.
The stove needs to be connected to a single chimney that
guarantees the draught declared by the Manufacturer and
observes the installation regulations that apply to the installation
site.
The room where the stove is installed must have an air intake.
The stove must not be used as an incinerator or differently
from its purpose
Use and maintenance manual Touch Radio Hydro
Pag.8
Rev.2 06/04/2021
Do not use any fuel other than fire pellet. It is strictly forbidden
to use liquid fuels.
It is prohibited to use the stove with the door or ash drawer
open or the glass broken.
Do not touch the hot surfaces of the stove without suitable
protective equipment, to avoid getting burned. When it is
running, the outer surfaces reach hot temperatures to the
touch.
It is forbidden to make unauthorised changes to the stove.
Before using the stove it is necessary to know the position and
function of the controls.
If the chimney catches fire you must call the fire brigade.
Only use original spare parts. Any tampering and/or
replacements that have not been authorised by Ravelli can
pose a danger to the user’s safety.
In the event of particularly adverse weather conditions, the
safety systems could intervene and switch off the stove. In any
case, doe not disable the safety systems.
Residual risks
The stove was designed so as to guarantee the user’s essential
safety requirements.
Safety was integrated into the stove’s design and construction as
much as possible.
For every residual risk there is a description of the risk and the zone
or part that is applies to (unless the risk applies to the entire stove
overall). Procedure-related information is also provided on how to
avoid the risk and on the correct use of the personal protective
equipment required by and made compulsory by the Manufacturer.
Use and maintenance manual Touch Radio Hydro
Pag.9
Rev.2 06/04/2021
residual
risk
description procedure-related information
Risk of
burns When the stove is running, it may reach high
temperatures to the touch, especially on its external
surfaces. Take care to avoid burns and use the specic
tools if necessary.
Use the supplied glove to open pellet cover for loading
operations.
DESCRIPTION OF THE STOVE
Intended use
The appliance in question is intended for:
operation allowed fuel forbidden setting
Domestic space
heating by
burning:
pellet Any fuel other
than the
permitted ones.
Residential
or
Commercial
The stove is designed and built to work safely if:
it is installed by qualied sta according to the specic standards;
it is used within the limits declared in the contract and herein;
the operating manual procedures are followed;
routine maintenance is carried out according to the times and
methods set forth;
extraordinary maintenance is promptly carried out when needed;
safety devices are not removed and/or bypassed.
📌This stove must be intended for the use it was specifically
designed for.
Reasonably foreseeable incorrect use
Reasonably foreseeable incorrect use is listed below:
using the stove as an incinerator;
using the stove with fuel other than pellet;
using the stove with liquid fuels;
using the stove with the door open and the ash drawer out.
Any use of the appliance other than intended must be preventively
authorised in writing by the Manufacturer. Without said written
authorisation, the use is considered “improper”. Any contractual
and non-contractual liability of the manufacturer is excluded for
damages to persons, animals or property due to installation and
maintenance adjustment errors and improper use.
Use and maintenance manual Touch Radio Hydro
Pag.10
Rev.2 06/04/2021
Obligations and forbidden actions
Obligations
The user must:
read this instructions manual before performing any operation
on the stove;
the appliance must not be used by children under the age of 8 or
by people with reduced physical, sensorial or mental capacities
or without experience or without the necessary knowledge, and
always with supervision;
do not use the stove improperly, i.e. for uses other than those
described in the “INTENDED USE” paragraph;
it is strictly forbidden to use liquid fuels;
keep objects that are not heat and/or ame-resistant at a safe
distance;
only and exclusively load the stove with pellet with the
characteristics described herein;
connect the stove to a regulation chimney;
provide a suitable system for the supply of combustion air (air
intake or intake duct for watertight stoves);
always perform maintenance with the stove o and cold;
perform cleaning activities at the frequency stated herein;
use original parts recommended by the Manufacturer.
Forbidden actions
The user must never:
remove or change the safety devices without authorisation;
perform operations or manoeuvres of his/her own initiative that
are not part of his/her job description, meaning that he/she might
jeopardise his/her own safety and that of others;
use fuels other than pellet and those allowed for lighting;
use the stove as an incinerator;
use ammable or explosive substances near the stove during
operation;
use the stove with the door open and/or with the glass ruined or
broken;
close the combustion air and smoke outlet openings, whatsoever;
use the stove to dry laundry;
replace or change some of the stove parts.
Use and maintenance manual Touch Radio Hydro
Pag.11
Rev.2 06/04/2021
Characteristics of the fuel
Wood pellet is a fuel made of pressed wood sawdust, often recovered from processing scraps of carpentries. The material used
cannot contain any extraneous substance such as, for example, glue, lacquer or synthetic substances.
The sawdust, once it has been dried and cleaned from impurities, is pressed using a die with holes: as a result of high pressure, the
sawdust heats up by activating the natural wood binders; this way the pellet maintains its shape even without adding articial
substances.
Wood pellet density varies based on the type of wood and can exceed that of natural wood by 1.5 - 2 times.
The cylinders have a diameter of 6 mm and a variable length between 10 and 40 mm.
Their density is equal to approximately 650 kg/m3. Due to their low water content (< 10%) they have a high energy content.
The UNI EN ISO 17225-2:2014 standard (that replaces the EN PLUS standard) denes pellet quality by specifying three classes: A1,
A2 and B. Maintain fuels and other ammables at a suitable distance.
Ravelli recommends using wood pellet classied A1 and A2 according to the EN ISO 17225-2:2014 standard, or certied DIN PLUS
(more restrictive than the A1 class) or ONORM M 7135. Pellet may be light or dark coloured, it is normally bagged into bags that show
the name of the producer, the main characteristics and classication according to standards.
📌 Pellets must be transported and stored in a dry area. Upon contact with humidity they swell and become unusable
📌 It is therefore necessary to protect them from humidity, both during transport and during storage.
Non-permitted fuels
We recommend not using the following materials as fuel:
wood
treated wood (painted, lacquered, glued wood etc.);
sawdust or chips
liquid fuel
coal or other fossil fuels
plastic and derivatives
treated paper and cardboard
waste
fuels that release toxic or polluting substances
Using these fuels, on top of being forbidden due to the emission of polluting and harmful substances, causes the stove to deteriorate
more rapidly and debris to accumulate in the stove and in the smoke evacuation system, thereby reducing performance and safety.
📌The gases produced by these fuels are dangerous for the environment and for your health!
📌Using fuel that is not compliant with the above will void the warranty.
Use and maintenance manual Touch Radio Hydro
Pag.12
Rev.2 06/04/2021
Automatic cleaning system
The stove is equipped with automatic brazier cleaning system. This means that there is no need to carry out daily manual cleaning
of the brazier or every time the stove is lit. The automatic cleaning system is activated every time the stove is lit and after 6 hours of
continuous operation. The cleaning cycle, which involves shutting down, automatic cleaning and restarting the stove, takes about 10
minutes. During this period the heating is guaranteed by the heat accumulated by the appliance itself.
Note: the times indicated are those set by default by the Manufacturer.
Recharge the fuel
Use only wood pellets, the characteristics shown in this manual.
During pellet loading prevent the pellet bag from coming into contact with hot surfaces.
📌It is not recommended to empty the pellet bag directly into the hopper to avoid depositing wood sawdust on the bottom of
the hopper.
Doors opening
The combustion chamber door and the ash drawer can only be opened when the stove is in the OFF state.
If one of them is not closed, the pellet supply is interrupted, the control unit emits an acoustic warning signal, while the symbol ap-
pears on the display:
In this condition, by touching the CONFIRM button you can read the detail of the warning: “doors and ash pan open”. If the combus-
tion chamber door and / or the ash drawer are not closed within 1 minute, the stove switches off signalling ALARM 07.
Opening the doors also interrupts the automatic cleaning phase of the brazier. In the event of a prolonged interruption of the cleaning
phase, ALARM 19 may appear.
Remember that in the presence of an alarm the stove will have to be restarted manually.
User training
Once installation is complete, the user must always be fully trained in the functions and characteristics of the stove by the technician
authorized by Ravelli to ensure optimal and safe use.
The training should cover the following topics:
Description of the stove, its operation and basic settings
How to turn the stove on and off safely
Fuel storage and refilling
What to do in the event of an alarm, in particular that of “no ignition”
How to clean the stove correctly and the importance of performing it on a regular basis
It is advisable to schedule the first annual maintenance
Use and maintenance manual Touch Radio Hydro
Pag.13
Rev.2 06/04/2021
Safety devices
The stove has been designed and equipped with safety systems to minimize user risks.
It is equipped with the safety devices listed in the following table, which also intervene in case of failure of the electronic board.
Element Description
Water temperature thermostat If the water temperature exceeds the set safety value, it immediately stops the pellet load-
ing motor and the stove is automatically switched off; to restart it, it is necessary to wait
until it has cooled down and manually reset the thermostat, using the appropriate button.
Pressure switch If the pressure in the smoke outlet duct is too high (a sign that the smoke evacuation sys-
tem is obstructed) it immediately stops the pellet loading motor and the stove switches off
automatically.
Limit switch for closing combustion
chamber door, ash drawer and pellet
hopper lid
If the door of the combustion chamber, the ash drawer or the pellet hopper lid are not
properly closed, it immediately stops the pellet loading motor; if they are not closed within
60 seconds, the stove switches off automatically.
Safety valve for water overpressure In the event of overpressure of the hydraulic system, the safety valve opens discharging
water, so that the stove is not damaged.
Electrical safety In case of failure of the electrical components or wiring, the fuse and grounding keep the
appliance safe. It is necessary that the electrical system of the house is up to standard,
equipped with a grounding circuit and all the safety systems required by the standards.
It should be noted that the stove’s operating program has been designed to stop stove operation in the event of malfunctions:
Anomalies Description
Temperature in the combustion cham-
ber
If the temperature probe in the combustion chamber detects temperatures that are too
high or too low, the stove is switched off and the relative alarm is displayed.
Flue gas temperature If the temperature probe at the smoke outlet detects temperatures that are too high, the
stove is switched o and the relative alarm is displayed.
Water over-temperature If the water temperature in the boiler of the stove, detected by the appropriate probe, is too
high, the stove is switched off and the relative alarm is displayed.
Water pressure If the water pressure in the boiler of the stove, detected by the pressure transducer, is too
high or too low, the stove is switched off and the relative alarm is displayed.
Smoke fan break If the fan stops, the electronic board blocks the supply of pellets and the alarm is displayed.
Gear motor failure If the gear motor stops, the appliance switches off safely.
Temporary power failure If a power failure occurs during operation, when the power returns the temperature in the
combustion chamber is checked and, if necessary, the stove goes into cooling mode.
No ignition If no ame develops during the ignition phase, the stove goes into alarm.
It is forbidden to tamper with the safety devices. Restarting the product is only possible after eliminating the cause that
caused the intervention of the safety system. To understand which anomaly occurs, consult this manual which explains,
depending on the alarm message that the device displays, how to intervene on it.
If the problem persists, contact the Support Service.
Use and maintenance manual Touch Radio Hydro
Pag.14
Rev.2 06/04/2021
SHIPPING AND INSTALLATION
Safety warnings for transportation and installation
📌The stove must be installed by a qualied technician, who must issue a declaration of conformity of the system to the
purchaser, taking full responsibility for stove installation and correct operation.
📌The stove installation site must be chosen so that the generated heat can spread evenly throughout the rooms that you wish
to heat.
The stove needs to be connected to a single chimney that guarantees the draught declared by the Manufacturer and
observes the installation regulations that apply to the installation site.
The room where the stove is installed must have an air intake.
The air vent must be installed in such a way that it can not be blocked.
The Manufacturer will not be held liable for installation that is not compliant with the laws in force, incorrect air circulation in the rooms
and inappropriate use of the appliance.
In particular, it is necessary:
that the appliance be connected to a smoke evacuation system duly sized to guarantee the draught declared by the Manufacturer,
that is tight and observes the distances from ammable materials;
that there is a suitable combustion air intake in compliance with the type of installed product;
that other installed combustion appliances or devices do not create a vacuum in the room where the stove is installed;
that the safety distances from ammable materials are observed.
Verication of system compatibility has a priority over any other assembly or installation operation.
📌Local administrative regulations and particular requirements of the authorities pertaining to the installation of combustion
appliances, the air intake and the smoke evacuation system, may vary based on region or nation. Check with your local
authorities if there are stricter laws than set forth herein.
Packaging
When the stove arrives, check:
that it is the model you ordered;
that it has not been damaged during shipping.
Any complaints must be reported to the deliveryman (also on the delivery note) upon receival.
Check the capacity of the floor before handling and positioning the stove.
To handle the stove in its packaging, follow the procedure below:
1Position the pallet truck forks in the slots under the wooden pallet.
2Lift slowly.
3Place the stove near the chosen location for installation.
The stove always needs to be handled vertically. Take extra care to protect the door and its glass against mechanical impact
that could jeopardise their integrity
.
To unpack the stove, follow the procedure described below:
1Cut the straps and remove the wooden reinforcement frame resting on the box
2Slowly lift the cardboard box
3Remove any bubble-wrap or similar
4Remove the stove from the pallet and position the appliance in the chosen location, ensuring that it is compliant with
the directions.
📌The end user is responsible for disposing of the packaging in accordance with the laws in force in the country of installation.
Use and maintenance manual Touch Radio Hydro
Pag.15
Rev.2 06/04/2021
Set-ups for the smoke evacuation system
📌Be careful when building the smoke evacuation system and observe the regulations in force in the country where the stove
is installed.
The Manufacturer will not be held liable for incorrectly sized and non-regulation smoke evacuation systems.
Smoke ducts and ttings
The term smoke duct indicates all ducts that connect the combustion equipment to the chimney.
The following requirements need to be applied:
observe product standard EN 1856-2;
the horizontal sections must have a minimum slope of 3% upwards;
the length of the horizontal section must be as minimum as possible, and its projection on the horizontal plane must not exceed
2 metres;
changes in direction must not have an angle of more than 90° (45° bends are recommended);
the number of direction changes, including the one necessary for insertion into the chimney, must not exceed 3;
the cross section must have a constant diameter, the same from where it exits the rebox up to the tting into the chimney;
it is forbidden to use exible metal and bre cement pipes;
smoke ducts must not cross rooms where the installation of combustion equipment is prohibited.
In any case, the smoke ducts must be sealed against combustion products and condensation, as well as insulated if they lead outside
of the installation room.
Installing manual draught adjustment devices is not allowed.
Chimney
The chimney is a particularly important element for correct stove operation.
The chimney must be sized so as to guarantee the draught declared by the Manufacturer.
Do not connect the stove to a collective chimney.
The chimney must be built applying the following regulations:
it must observe product standard EN 1856-1;
it must be made of materials that are suitable to guarantee resistance against normal mechanical, chemical and thermal stress
and be correctly thermally insulated to limit the formation of condensation;
it must be mainly vertical and not feature any bottlenecks along its entire length;
it must be correctly spaced with an air gap and insulated from ammable materials;
there must be a maximum of 2 changes in direction and angles must not exceed 45°;
the chimney inside the home, however, must be insulated and can be inserted into a skylight shaft, as long as it respects
standards regarding placing inside a tube;
the smoke conduit must be connected to the chimney using a “T” tting with an inspection collection chamber for combustion
residue and especially for collecting condensation.
📌It is necessary to check the safety distances that need to be observed when there are flammable materials and the type of
insulating material that needs to be used is on the chimney data plate.
Use watertight pipes with silicone seals.
It is forbidden to use the discharge mounted directly on the wall or directed towards indoor spaces and any other type of
discharge that is not set forth by the regulation in force in the country of installation (Note: in Italy only roof-discharge is
allowed).
Chimney pot
The chimney pot, i.e. the top end of the chimney, must full the following characteristics:
the cross-section of the smoke outlet must be at least twice the internal cross-section of the chimney;
it must stop water or snow from getting in;
make sure the smoke is taken away even when there is wind (wind resistant chimney pot);
the outlet height must be outside of the reux zone (refer to national and local regulations to calculate the reux zone);
it must always be built at a distance from antennas or dishes, it must never be used as support.
Use and maintenance manual Touch Radio Hydro
Pag.16
Rev.2 06/04/2021
Installation
For appliance installation and use it is necessary to observe all of the local, national and European laws and regulations.
Stove installation and the preparation of the building work must observe the regulation in force in the country of installation
(ITALY = UNI 10683).
📌The installation activities must be carried out by a technician that is qualified and/or authorised by the Manufacturer. The staff
in charge of installation must issue a declaration of conformity of the system to the buyer, whereby they take full responsibility
for the final installation and good operation of the installed product.
📌Ravelli shall not be held liable if these precautions are not followed.
Requirements for the installation premises
The stove installation room must be suciently ventilated. To full this requisite it is necessary to equip the room with an air intake
connected to the outdoors.
📌The installation room must have an air intake with a free cross-section of at least 80 cm2.
📌For installation in the presence of other combustion appliances or VMC system it is necessary to check the appliance for
correct operation.
The stove must be placed inside living quarters. It must never be installed outdoors. The volume of the room where it is installed
must be suitable for the power of the appliance and, in any case, greater than 15 m3.
When extraction fans (example: extraction hoods) are used in the same room or space as the stove, this can cause problems
to stove operation.
The stove must be installed on a floor with suitable load capacity. If the existing position does not fulfil this requirement, it is
necessary to take due measures (for example, using a load distribution plate).
Provide due insulation if the surface is made of flammable material.
If the side walls adjacent to the stove are made of a ammable material, it will be necessary to position the stove at least 30 cm from
them.
If the oor that the stove is standing on is ammable, we recommend duly insulating it. Objects and parts that are heat-sensitive
or ammable cannot be stored near the stove;in any case, keep such objects outside the area bounded by the minimum distances
indicated above.
Stove installation must guarantee easy access to clean the appliance, the exhaust ducts and the chimney.
Use and maintenance manual Touch Radio Hydro
Pag.17
Rev.2 06/04/2021
This type of installation (See Fig.1) requires an insulated chimney
pot, even if the entire conduit is installed inside the building.
Besides, the structure must be inserted into a properly ventilated
skylight shaft.
In the lower part of the chimney pot there is an inspection cover,
properly isolated from wind and rain.
It is possible to use an existing chimney or a shaft via ducting. For
this type of installation the standards on ducted smoke evacuation
systems must be complied with. In the lower part of the chimney
pot, inside the home, there is a "T" type tting installed; externally
there is another one installed, so that the outside section can be
inspected.
It is prohibited to install two 90° bend, since the ashes would
quickly obstruct smoke passage, causing draught problems in the
stove. (See Fig. 2)
Ashes deposited in the
90° bend
NO
Installation example for a stove/pellet stove
Smoke duct: use of a
non-insulated tube
T Fitting
Insulated chimney
Fig.3
Protection from rain
T tting for
condensation
Combustion ashes
collection chamber
+ condensation cap
Protection from rain
Fig.1
Grille for air passage into
the skylight shaft with
opening for inspecting the
chimney
Skylight shaft
T tting for condensation
Insulated chimney
It is prohibited to install a 90° bend for the initial segment, since
the ashes would quickly obstruct smoke passage, causing draught
problems in the stove. (See Fig. 2)
Use and maintenance manual Touch Radio Hydro
Pag.18
Rev.2 06/04/2021
This type of installation (See Fig.4) requires an insulated chimney
pot, even if the entire smoke conduit is installed outside the
building.
In the lower part of the chimney there is a "T" type tting installed
with inspection cap.
It is prohibited to install a 90° bend for the initial segment, since
the ashes would quickly obstruct smoke passage, causing draught
problems in the stove. (See Fig.2)
This type of installation (See Fig.5) requires an insulated chimney
pot, since the entire smoke conduit is installed inside the building,
and the part is located inside a pre-existing chimney pot.
In the lower part of the stove there is a "T" type tting installed with
inspection cap just like for the chimney pot.
It is prohibited to install a 90° bend for the initial segment, since
the ashes would quickly obstruct smoke passage, causing draught
problems in the stove. (See Fig.2)
INTERNAL CHIMNEY
Fig.5
Protection from rain
Covering sheet
Air-tight steel sheet metal
T tting with collection
chamber for condensation
Inspection hatch
Fig.4
Protection from rain
Insulated chimney
T tting with con-
densation drain and
collection chamber
This type of installation (See Fig.6) requires a horizontal section to
connect to a pre-existing chimney pot.
Respect the slope indicated in gure, in order to reduce the ashes
depositing in the horizontal tube. In the lower part of the chimney
pot, there is a "T" type tting installed with inspection cap, in the
same was as the chimney pot opening.
It is prohibited to install a 90° bend for the initial segment, since
the ashes would quickly obstruct smoke passage, causing draught
problems in the stove. (See Fig.2)
2 - 3 mt max
Height exceeding 4 mt
Slope 3 - 5 %
Max 2 -3 mt
INTERNAL CHIMNEY
Fig.6
T tting for
condensation
Inspection hatch
Protection from
rain
Use and maintenance manual Touch Radio Hydro
Pag.19
Rev.2 06/04/2021
CONNECTIONS
📌The connections must be set up by a technician that is qualified and/or authorised by the Manufacturer.
📌By the installer the type of cable, with relative section, to be installed in case of replacement is: H05RR-F sez.3G0,75
Chimney connection
The chimney must be sized so as to guarantee the draught declared by the Manufacturer.
The stove must be connected to a single flue. It is forbidden to connect the stove to a flue shared with other combustion
appliances or with hood exhausts.
The flue must be inspectable for cleaning.
Components
This stove is equipped with the following control and safety components:
3 bar safety valve;
Booster pump control thermostat (integrated in the functions of the electronic board);
Acoustic alarm activation thermostat (integrated in the functions of the electronic board);
Temperature indicator (integrated in the functions of the electronic board, with display);
Pressure indicator (integrated in the functions of the electronic board, with display);
Acoustic alarm (integrated in the functions of the electronic board);
Automatic regulation thermal switch (integrated in the functions of the electronic board);
Automatic blocking thermal switch (manual reset thermostat);
Circulation system;
Expansion system (Expansion vessel).
Local laws and regulations (for example the UNI 10412-2 standard valid in Italy) could provide for other safety components. In this
case they must be mounted in the system.
The construction of a heating system with the relative installation of the boiler must comply with all national and local regulations in
force in the place where the system is carried out.
Stove-system connection
¾" RITORNO IMPIANTO
¾" MANDATA IMPIANTO
Ø18 SCARICO SICUREZZA
Connect the stove to the hydraulic system so as not to constrain it excessively and to allow it to move slightly.
📌Before connecting the thermo-stove, it is strongly recommended that the system be thoroughly washed in order to eliminate
residues and deposits.
Ø18 Safety drain
3/4’’ Flow
3/4’’ Return
Use and maintenance manual Touch Radio Hydro
Pag.20
Rev.2 06/04/2021
Electrical connection
The plug of the stove’s power cable must only be connected after the installation and assembly has been completed of the
appliance, and must remain accessible after installation.
To make the electrical connection, proceed as described below:
First connect the power cable to the plug on the back of the stove and then to a wall socket.
Supply power to the stove by turning the switch to position (I).
📌When the stove is not in use, it is advisable to disconnect the power cable.
Take care that the power cord (and any other cables outside the equipment) do not come into contact with hot surfaces.
Ensure that the electrical system is grounded.
For direct connection to the mains, it is necessary to provide a device that ensures disconnection from the mains, with a
contact opening distance that allows complete disconnection under the conditions of over-voltage category III, in accordance
with installation rules
If the power supply cable is damaged, it must be replaced by the manufacturer or its technical assistance service or in any
case by a person with similar qualifications, so as to prevent any risk.
It is recommended that authorized personnel pay special attention to the electrical connections after any work on the product.
Switch
Power plug
Fuse
Connection of external probe or thermostat
To manage the ducting in automatic mode, connect a temperature probe (optional) or external thermostat (optional) to the connector.
📌Connect an open/closed external thermostat, therefore potential-free.
📌If you wish to detect the ambient temperature by means of an external thermostat (optional), this must be connected to
the appropriate connector on the rear side of the stove; and you will have to activate the reading in “SETTINGS - ENABLE
THERMOSTAT.” On display appears the writing TON / TOFF based on thermostat request.
Connect an external thermostat with a simple dry contact, therefore, not powered, moreover, we recommend you use a
thermostat with a minimum offset of 3°C if you intend to use the “comfort clima” function.
Testing and commissioning
Stove start-up must be preceded by testing, which includes an operational check of the following elements:
connection to the smoke evacuation system;
electrical connections;
hydraulic connections;
operation of any connected external probes;
checking that all materials used to build the smoke duct, chimney and chimney pot are regulation and suitable for use.
The testing is positive only when all operational phases have been completed without any anomaly being detected.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

Ravelli HRV 250 Use and Maintenance Manual

Categoria
Stufe
Tipo
Use and Maintenance Manual
Questo manuale è adatto anche per

in altre lingue