Davey EcoSalt DES13CE Manuale del proprietario

Tipo
Manuale del proprietario

Questo manuale è adatto anche per

Page 1 of 18 P/N 403185
Salt water pool system
Desinfektionssystem unter verwendung des salzwassers
Trattamento ad acqua salata
Badzout zwembad systemen
Tratamento da água da piscina com base na adição de sal
Sistema de sal para piscinas
Traitement au sel pour piscines
Sections
1 English Owners Manual
2 Deutsch Handbuch für kaüfer
3 Italiano Manuale di installazione e di manutenzione
4 Dutch Gebruikers handleiding
5 Português Manual de instalação e de manutenção
6 Español Manual de instalación y de mantenimiento
7 Français Manuel d’installation et d’entretien
EcoSalt
®
Page 2 of 18 P/N 403185
Page 3 of 18 P/N 403185
Salt Water Pool System.
The Natural Solution for Pools & Spas.
Owners Manual
EcoSalt
®
Page 4 of 18 P/N 403185
Salt Water Pool System.
The Natural Solution for Pools & Spas.
Congratulations! You are now the proud owner of the advanced EcoSalt Salt Water Pool
Sanitising System. Please read all information in this Manual carefully before installing
or operating your EcoSalt System
INDEX
Page 5 Packing List
Page 5 Important Notice
Page 5 Installation Instructions
Page 7 Important Instructions for Use
Page 8 Pre Start up Procedure
Page 8 Operation of EcoSalt System
Page 10 EcoSalt Special Features
Page 11 Maintenance of Power Supply
Page 11 Maintenance of Electrolytic Cell
Page 13 Day to Day Operation
Page 14 Running Times & Chlorine Production
Page 16 General Information
Page 17 Trouble Shooting
Page 18 Typical Installation
WARNING
1. This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety
2. Children should be supervised to ensure that they don’t play with the
appliance
3. This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved.
4. Children shall not play with the appliance.
5. Cleaning and user maintenance shall not be made by children without
supervision.
6. If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
EcoSalt
®
Page 5 of 18 P/N 403185
PACKING LIST
Included with your EcoSalt system are the following items, please check the contents
carefully prior to installing the system:
1. Power Supply
2. Electrolytic Cell
3. 2 x Barrel Union Sets
4. Flow Switch
5. Blanking Cap Assembly
6. Earthing System Assembly
7. Mounting kit and spare fuse
Please note product specifications are subject to change without notice. Please consult
your EcoSalt dealer if you have any queries regarding the above.
IMPORTANT NOTICE: A means of full disconnection must be incorporated into the
fixed wiring in accordance to local wiring rules.
INSTALLATION INSTRUCTIONS FOR ECO-SALT
INSTALLING THE POWER SUPPLY:
Select a convenient well-ventilated location within one metre of filter equipment and
mount the Power Supply vertically onto a post or wall 1.5 metres above ground level.
The Power Supply should not be located within 3 meters of the pool water.
Connect Power Supply into a suitable weatherproof outlet or an independant
control box. The Unit must be kept away from acid and other chemical storage areas.
Acid and chemical vapours will corrode the electronics inside the Unit. It must also be
kept away from heat sources. Good ventilation is necessary for correct operation (See
installation diagram on page 18).
Two self-tapping screws and wall plugs have been provided for fast and simple
installation. Use a 7mm masonry drill bit when fitting Power Supply to a brick or concrete
wall. When mounting to a post drill pilot holes and fit screws provided. Once screws are
in position simply hang chlorinator via bracket on back of Unit.
Page 6 of 18 P/N 403185
CONNECTING THE ELECTROLYTIC CELL TO THE POWER SUPPLY:
The Power Supply is fitted with a flexible
lead terminated with connectors. These
must be correctly fitted to the
connections on the underside of the
Cell. Fit black connectors to the outer
titanium rods. Fit the white connector the
middle titanium rod. Ensure the
connectors are tight when inserted.
Important: The Cell has to be
connected as shown.
Note: The Cell is supplied with a paddle type flow switch, which is to be installed
on the Cell as shown in the diagram on page 6 and 7.
CONNECTING THE FLOW SWITCH TO THE POWER SUPPLY
Join the connector on the flow switch and the connector on the cell cable together. They
will clip together.
Note: The bolt included, the saddle clamp, is for a connection to an independent earth.
IMPORTANT: Do not operate the unit with pool isolation valves closed as possible
pressure build-up may cause the cell the break open. Such damage will not be
covered under warranty. For valve use, refer to your pool installer/builder.
IMPORTANT: The ow switch must be mounted with the highlighted arrow
on top of the switch pointing in the direction of ow.
Page 7 of 18 P/N 403185
IMPORTANT INSTRUCTIONS FOR USE
To minimise the risk of gas build-up in the cell, you must ensure there is
sufficient water flow through the cell when the unit is on and producing
chlorine.
It is essential that your pool pump circulates sufficient water through the cell to
completely fill the cell with water during the chlorination process. The minimum
flow rate through the cell is 3.5m
3
/ hr.
Periodically check the paddle of the safety flow switch to ensure it is free to
move back and forth.
Diagram A
CORRECT
OPERATION
WITH PUMP
RUNNING
Flow switch O N .
ü
Flow switch O FF.
Diagram B
INCORRECT
OPERATION
WITH PUMP
RUNNING
û
Flow
Flow
Page 8 of 18 P/N 403185
PRE - START UP PROCEDURE:
Before operating your EcoSalt ensure the following items have been added to your pool:
SALT - Load salt into the pool at a minimum rate of 40kg per 10,000 litres (0.4%).
Connect vacuum system and slowly vacuum until salt dispersal is complete. Place
vacuum head into deepest end of pool and allow vacuum to continue for a further 2 or 3
hours. Salt should now be completely disolved.
CHLORINE - For a new pool installation that has not been chlorinated, add sufficient
Chlorine (liquid or granular) to achieve a reading of 3 ppm (with a suitable test kit), or run
the chlorinator system continuously for at least 24 hours or until a reading of 3 ppm is
reached.
STABILISER - It is essential that pool stabiliser be added and maintained at the rate
of 30 - 50 mg/l (30 - 50 ppm) at all times. Do not exceed 80 ppm. If you are using an
ORP controller, the stabiliser level should not exceed 15ppm.
OPERATION OF ECOSALT SYSTEMS:
Cell Output is expressed as a percentage. Set the system control to the percentage
output required and the unit will automatically adjust the cell output to the set level. The
Unit is fitted with an electronic control and warning system. This regulates the output of
the Unit to the preset maximum and changes cell polarity as indicated by POLARITY
LEDs A & B. These LEDs will alternate over a number of hours or days depending on
how the unit is set to operate. The warning system consists of one Operation LED
which will glow Green to indicate normal operation or Red to indicate possible faults with
the Unit or damaging operating conditions.
Page 9 of 18 P/N 403185
Control Panel Layout:
Once the salt level in the pool is correct the Unit may be switched On. (Note: Once the
unit starts there is a short time delay until the cell operates to ensure filtration
system is primed with water) At this point the Operation LED should be Green; if red
refer below. Note: Polarity LED may be either A or B (whichever is on or brightest).
The RED Operation LED will indicate a number of different possible problem situations:
Possible Problem
Action
Salt Level Below Minimum Add Salt
Cell is Calcified Clean Cell
Water temperature very cold Add salt to compensate for cold water
There is a problem with water flow
Check pump / pipes for blockage or damage.
Check that flow sensor is connected properly
and in the right direction.
Control Panel Layout:
Page 10 of 18 P/N 403185
ECOSALT SPECIAL FEATURES
SYSTEM CONTROL:
The System Control varies the amount of time the Cell operates during the
filtration cycle.
The System Control will not vary the electrical current supplied to the Cell.
As an example, if one filtration cycle is set at 5 hours, and the System Control is set to
80%, then the total amount of time the Cell will operate during the 5-hour cycle will be 4
hours. If the System Control is set to 60%, the Cell will operate for 3 hours total over
the 5-hour filtration cycle. At 100% the Cell will be ON for the entire 5 hour cycle.
When the System Control is set to 0, the Cell will be OFF for the duration of the
filtration cycle. When the System Control is set to 100%, the Cell will be ON for the
duration of the filtration cycle.
To turn the Cell OFF, simply turn the System Control to 0. This will be convenient for
backwashing. To turn both power supply AND cell OFF, turn the ON/OFF to 0.
POLARITY A & B:
These LEDs are used to check that the Cell current polarity is reversing. Whichever is
on (or brightest) indicates the polarity of operation. The Cell will operate in one polarity
for a number of hours so any change in these LEDs will happen slowly and depend on
how the unit is operated.
LOW SALINITY INDICATION
Your EcoSalt is fitted with a number of protective systems including the operation LED
whose primary function includes Low Salinity Indicator. As the salt level in the pool
decreases, the wear on the Cell increases. Although salt is not consumed in the
EcoSalt process, it is lost through splashing, back - washing and on bathers as they
leave the pool. The salt level is also reduced by rain, which causes dilution. Salt is not
lost to evaporation. As the salt level in the pool falls toward the minimum Operation
LED will turn RED. At this point the salt level should be increased by adding 25kg of salt
per 25,000 litres of pool water. The addition of salt should not affect the EcoSalt as it is
protected against overloads. If no action is taken and the salt level continues to fall
damage to the system may result.
There are other factors that can cause the Unit not to work correctly:
1. Heavy Rain - can cause very dilute pool water to pass over the Cell due to surface
skimming.
2. Scaled Cell - a scaled Cell will not draw as much electrical current as a clean Cell
when first started. Refer Maintenance of Electrolytic cell below.
3. Cold Water - cold pool water reduces the ability of a Cell to carry electrical current.
Addition of salt can help compensate for cold water. We recommend to switch off the
unit when water temperature is below 15ºC. Low temperatures can damage the cell.
Page 11 of 18 P/N 403185
4. Failing Cell - as the Cell ages there will come a time when the electrical current
draw will drop. This can be compensated for with the addition of extra salt. A Cell is
considered failed when it draws less than 80 % of maximum current.
Please note that the Low Salinity Indicator is not like T.D.S. meters, which are
temperature compensated Scientific Instruments. The accuracy will be within 500ppm
salinity and they are water temperature dependent, just as the Cell is.
SAFETY NOTICE
IMPORTANT: Certain local electrical regulations state “If the supply cord is
damaged, it must be replaced by a special cord available from the manufacturer or
its service agent”.
MAINTENANCE OF POWER SUPPLY:
Little or no maintenance is normally required with the exception of replacing blown
Fuses. These Fuses can be sourced from your local EcoSalt Dealer. However it is
essential that the wall or post to which the Unit is installed be sprayed (not the Unit itself)
with a good surface type insect repellent periodically since penetration by insects may
cause damage which is not covered by your warranty.
The back of the Unit has been designed as a heat sink. It is normal for this area to
become very hot.
MAINTENANCE OF ELECTROLYTIC CELL:
The cell is composed of precious materials, and although proper maintenance can
prolong its life to the maximum, eventually the process of electrolysis will wear away its
delicate coating, at which time it gradually ceases to produce chlorine.
Mineral salts and calcium (scale) are deposited on the outer and the inner plates as
electrolysis takes place. This build up will interfere with the flow of electrical current in
the Cell and thus lowers sanitiser production. It is essential to inspect the Cell regularly
and clean when necessary. The rate at which deposits will form on the cell plates differs
with each pool and can be influenced by the following:
Calcium hardness of the water
Water Temperature
pH Control
Water which has been chlorinated with cacium hypochlorite for an extended period
Calcium in the plaster surfaces of a concrete pool
Because these conditions vary so much, check the Cell at least weekly to begin with to
see when either scale or a blue/green soapy substance appears on the plates. You will
then be able to determine the cleaning cycle necessary for your pool (obviously more in
summer). The intervals between cleaning could get longer to the point where cleaning is
only necessary a few times each year. One exception is the use of bore water or ground
water, in which case cleaning may always need to be as frequent as once a week.
Page 12 of 18 P/N 403185
NOTE: In areas with hard water, reverse polarity systems may require occasional
manual cleaning
Life of EcoSalt electrolytic cells vary substantially from one installation to another due to
variations in operating time, water quality and composition, system and cell
maintenance. Please ensure that when cell replacement is necessary you use the
correct genuine EcoSalt replacement cell to match your system.
Refer to your local EcoSalt dealer for the correct cell for your model.
To clean the EcoSalt In-line Cell
Ensure that the Power Supply is turned off – failure to do so may result in the pool pump
turning on while the Cell is not in place. Disconnect the cell lead and flow switch from the
Cell and remove the Cell from the pool return line by undoing the unions, taking care not
to lose the o-rings.
METHOD
1. Assemble a blanking cap from the supplied plug, o-ring and lock ring.
2. Install the blanking cap onto the end of the Cell opposite the flow switch port.
3. Secure the Cell in a vertical position with the blanking cap at the bottom, to catch any
spills the Cell should be placed in an acid proof container.
4. Add 50mL of HYDROCHLORIC ACID to 500mL of WATER in a suitable sized
container; carefully pour the solution into the open end of the Cell.
Page 13 of 18 P/N 403185
5. Alternatively step 4 can be carried out using an approved commercial cell cleaning
solution.
6. As the scale is being dissolved from the plates the solution will foam, when this
foaming action has stopped the Cell is clean and the solution can be returned to the
container for future use or discarded appropriately. NOTE: do not leave the acid
solution in the Cell for more than ! hour.
7. Rinse the Cell out with clean tap water by filling and draining a couple of times, check
that all the scale deposits have been removed, repeat the cleaning process if
necessary.
8. Return the Cell to its position in the pipe work and re-connect the cell lead and flow
switch.
EcoSalt Units are also fitted with a Thermal cutout to prevent overheating. If the
temperature rises too high, power is automatically disconnected. The Unit will resume
operation when it cools down.
DAY TO DAY OPERATION:
Four Prime rules must be observed if your unit is to give the best possible service:
1. STABILISER
FOR OUTDOOR USE
The importance of pool stabiliser cannot be over emphasised. It is essential in helping
retain chlorine in your pool. Chlorine is rapidly dissipated by sunlight and the use of
stabiliser will reduce this dissipation dramatically. Without stabiliser, it may be
necessary to run the Unit for up to three times as long!
Stabiliser should be added at the rate of 500 grams for every 10,000 litres of water.
Stabiliser should be maintained at a level of 30 50 ppm. Before adding more
stabilisers, have your pool water analysed at your pool shop to ensure that you do not
add too much.
If you use an ORP controller, the stabiliser should not exceed 15ppm.
FOR INDOOR USE
Stabiliser is NOT needed for indoor pools and as such should not be used.
Please consult your local EcoSalt Dealer for more information on stabilising your
pool.
pH AND TOTAL ALKALINITY:
A correct pH level must be maintained to prevent problems such as black spot, staining,
cloudy water, etc. An incorrect pH level can damage the pool. Correct pH levels are as
follows; Fibreglass 7.0 to 7.4. Other pools 7.2 to 7.6. If you allow the pH level to rise
!"#$%&'()*+,&*--&*./-&01&)*0234&52623&*--&)*023&01&*./-7&'()*+,&)2*3&2+2&
83102.0/15&*5-&39::23&;(162,7&'()*+,&.(2*5&0<2&=2((&/5&*&)2((>6250/(*02-&*32*7
Page 14 of 18 P/N 403185
to 8.0 or above, the chlorine required could be as much as three times the normal
amount. To lower the pH add HYDROCHLORIC ACID. To raise the pH levels add
SODIUM BICARBONATE OR SODA ASH.
Total Alkalinity should not be confused with pH, although the two are closely related.
Total Alkalinity determines the speed and ease of pH change. It is measured in ppm
the ideal range is 80 – 150 ppm, or refer to your pool professional.
You should use a test kit which includes a test for total Alkalinity. Low Total Alkalinity
can cause unstable pH levels i.e. an inability to keep the pH constant may cause
staining, etching and corrosion of metals. High Total Alkalinity will cause constantly high
pH levels.
To lower add HYDROCHLORIC ACID (a little at a time). To raise add SODIUM
BICARBONATE.
3. SALT LEVELS:
The salt level MUST NEVER BE LESS THAN 4000 ppm (4.0 g/l). The ideal operating
salt level is 4500ppm (4,5 g/l). Operating the Unit with too little salt in the pool will
cause damage to your Cell. For DES units salinity must not exceed 7000ppm.
Salt is the essential element by which your Unit operates. Not enough salt means not
enough chlorine - this simple rule governs the total operation of your EcoSalt®, and
insufficient salt will damage your Cell.
Low salt levels will destroy the coating on the cell’s Anode materials and will void
all Warranty.
The EcoSalt has a built in warning system to minimise damage resulting from insufficient
salt levels, however, the ultimate responsibility is on the owner to ensure adequate salt
levels are maintained all year round.
NOTE: Swimming pools contain water with a low level of salinity, free chlorine and other
compounds. Any materials in contact with the pool water should be suitable for this
environment. DAVEY EUROPE can not be held responsible for damages that occur to
the materials of other products that come into contact with the water of the pool.
4. RUNNING TIMES & CHLORINE PRODUCTION:
These instructions cover EcoSalt in residential use only.
If you run your chlorinator for 24 hours a day, or for long periods, the Cell life will be
reduced dramatically. It is important that the correct model EcoSalt has been installed on
your pool. Many models are available to cope with small courtyard pools up to
commercial applications. (Consult your local EcoSalt Dealer for more information).
The EcoSalt must be run daily to generate sufficient chlorine to sanitise the pool. During
Summer this is usually minimum eight hours per day, preferably in two periods -
between 6.00 and 8.00am and between 5.00 and 11.00pm. Night time is preferable
because chlorine dissipates rapidly in direct sunlight. If these running times are
Page 15 of 18 P/N 403185
observed, and the Cell is functioning correctly, your pool will have sufficient chlorine
when tested in the morning.
If the level is too low either longer running times are required or the System Control
needs to be adjusted to maximum. Harsh local conditions such as traffic pollution or
windborne dust require different running times; in which case, seek advice from your
pool shop. During Winter and Spring approximately 4 to 6 hours a day should provide
enough chlorine. Without sufficient filtration/chlorination, your pool will never function
correctly. ALWAYS RUN THE FILTER WHEN SWIMMING IN THE POOL. In extremely
hot weather or during periods of heavy bathing loads, the running time may need to be
extended to 10 - 14 hours per day.
In some cases you may find your chlorine level to be too high. To determine if this is the
case, run your filter/chlorinator for the suggested times/chlorine production level and test
your pool water on the morning after operation. If your chlorine test shows a high level of
chlorine, either the running times can be reduced slightly, or the System Control can be
turned anti - clockwise. Test your chlorine level again the following morning at around
the same time. If your chlorine level is still high, repeat the above process until the
correct level is attained.
SUPER - CHLORINATION:
Periodically, especially during extremely hot conditions, it may be necessary to boost the
amount of chlorine in your pool in order to maintain absolute sanitation of the water. This
can be achieved by adding either liquid or granulated chlorine. If granulated chlorine is
added, the Cell must be checked regularly, since the additives from this product will clog
the electrodes. Alternatively, extend the running time of your EcoSalt chlorinator.
CHLORINE TYPES AND COMPARISONS:
EcoSalt
Model
Production
maximum
grams/hour
(100%)
Production
grams/hour
(65%
equivalent)
Chlorine
produced
over 8
hours
grams
(100%)
Equivalent in
dry
granulated
chlorine
grams
(65%)
DES13CE
13.0
20.0
104
160
DES20CE
20.0
30.8
160
246
DES26CE
26.0
40.0
208
320
Page 16 of 18 P/N 403185
GENERAL INFORMATION:
Algae - Microscopic forms of plant life which enter the pool by rain, wind and dust. There
are numerous varieties - some are free floating whilst others grow on walls and in cracks
and come in different colours. Some are more resistant to chemical treatment than
others.
Bacteria - The germs that contaminate your pool - generally introduced by swimmers,
dust, rain storms and other elements.
Balanced Water - The correct ratio of mineral content and pH level that prevents pool
water from being-corrosive or scale forming.
Chloramines - Compounds formed when chlorine combines with nitrogen from urine,
perspiration, etc. Chloramines cause eye and skin irritation, as well as unpleasant
odours.
Chlorine Demand - The chlorine required to destroy germs, algae and other
contaminants in the pool.
Chlorine Residual - The amount of chlorine remaining after chlorine demand has been
satisfied. This is the reading obtained with your test kit.
Cyanuric Acid - Also known as stabiliser or conditioner. It reduces dissipation of
chlorine by direct sunlight. Only needed in outdoor pools
Liquid Acid - Chemical used to reduce the pH and total alkalinity in the pool water, and
for cleaning chlorinator Cell.
ppm - An abbreviation for Parts Per Million the accepted measurement of chemical
concentration in swimming pool water. I ppm- l mg/L.
!"#$%$&'
()*+),*-..*/0.1)23+*431)56.3*,)*7))8*9-,31*)1*,:1);2:*<96==6+2*7))8*:0.1-;86>*)1*
<-+6,6<31*<0<,3=?*@<3*)A*/0.1)23+*431)56.3*9688*B)6.*9-11-+,0*)+*(-B30*71).;>,<?
Page 17 of 18 P/N 403185
WARRANTY INFORMATION:
Should you experience any difficulties with your Davey product, please contact the
Davey Dealer from which you purchased the Davey product. During warranty period, if it
is found that services are not covered by warranty, labour charges will apply.
Davey Water Products strives to reduce or eliminate any unnecessary expense by
producing this Manual. Experience has shown that by following this Manual - in
particular the section on Trouble Shooting, approximately 75% of all service calls are
unnecessary and the expense and frustration to clients could have been avoided. We
therefore strongly suggest that the owner read and absorb all information thoroughly.
All legitimate warranty claims on your Power Supply (parts and labour where returned to
the distributor) are free for the first 24 months from the date of installation.
IMPORTANT: ALWAYS INSIST ON GENUINE DAVEY REPLACEMENT PARTS. If it is
necessary to replace the Electrolytic Cell, beware of “look alikes”. Only the Genuine
Davey Cell is designed and warranted to operate with the Davey Power Supply.
SERIOUS DAMAGE MAY RESULT TO THE ELECTRONICS INSIDE THE UNIT IF
COPY CELLS ARE USED AND WILL VOID WARRANTY.
TROUBLE SHOOTING:
No Chlorine Production - Check for
1. Main power outlet switched off or Chlorinator not connected to mains supply.
2. Chlorinator fuse blown
3. Cell needs cleaning
4. Filter needs backwashing
5. Flow Switch not connected or incorrectly installed
6. Running times incorrect
7. Main house fuse blown
8. Low / No flow from pump
Low Chlorine Production - Check for
1. Dirty Cell - clean if required
2. Filter needs backwashing
3. Not set at correct production level/Cell failing
4. Pool stabiliser too low or Salt level to low
5. pH too high
6. Running times too short
Page 18 of 18 P/N 403185
TYPICAL INSTALLATION:
Locate cell after ALL other equipment
except ozone injection point
Seite 1 von 18 P/N 403185
Seite 2 von 18 P/N 403185
Salzwasser-Poolanlage.
Die natürliche Lösung für Schwimmbäder
und Whirlpools
.
Bedienungsanleitung
EcoSalt
®
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128

Davey EcoSalt DES13CE Manuale del proprietario

Tipo
Manuale del proprietario
Questo manuale è adatto anche per