Hitachi RAC-D14EX3 Manuale utente

Categoria
Condizionatori d'aria a sistema split
Tipo
Manuale utente

Questo manuale è adatto anche per

–1–
SPLIT TYPE AIR CONDITIONER
MODEL
RAS-D10EX3/RAC-D10EX3
INDOOR UNIT/OUTDOOR UNIT
INDOOR UNIT
Instruction manual
To obtain the best performance and ensure years of
trouble free use, please read this instruction manual
completely.
Manuale di istruzioni
Per garantire la migliore prestazione e la più lunga
durataleggere attentamente e al completo le seguanti
istruzioni
√‰ËÁ›Â˜ ¯Ú‹Û˘
OUTDOOR UNIT
RAC-D10EX3
RAC-D14EX3
RAS-D10EX3
RAS-D14EX3
°È· ÙËÓ Î·Ï‡ÙÂÚË ·fi‰ÔÛË ÙÔ˘ ÎÏÈÌ·ÙÈÛÙÈÎÔ‡
ηÈÁÈ· ÙËÓ Ì·ÎÚÔÚfiÕÂÛÌË ¯Ú‹ÛË ÙÔ˘ ¯ˆÚ›˜
ÚÔ‚Ï‹Ì·Ù·, ‰È·‚¿ÛÙ ÚÔÛÂÎÙÈο ·˘Ù¤˜ ÙȘ
Ô‰ËÁ›Â˜¯Ú‹Û˘.
HSILGNE
Page 1~26 Pag. 53~78
™ÂÏ›‰· 79~103
Manualde instrucciones
Para obtener el mejor funcionamiento y asegurar años
de uso libre de problemas, lea cuidadosamente este
manual de instrucciones.
27~52Página
RAS-D14EX3/RAC-D14EX3
–2–
SAFETY PRECAUTION
Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.
Pay special attention to signs of
Warning and
Caution”. The “Warning” section contains
matters which, if not observed strictly, may cause death or serious injury. The “Caution” section
contains matters which may result in serious consequences if not observed properly. Please observe
all instructions strictly to ensure safety.
The signs indicate the following meanings. (The following are examples of signs.)
Please keep this manual after reading.
This sign in the figure indicates prohibition.
Indicates the instructions that must be followed.
WARNING
CAUTION
Do not reconstruct the unit.
Water leakage, fault, short circuit or fire may occur if you reconstruct the unit by
yourself.
Please ask your sales agent or qualified technician for the installation of your
unit.
Water leakage, short circuit or fire may occur if you install the unit by yourself.
Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor, or the
earth line of telephone. Improper installation of earth line may cause electric
shock.
Be sure to use the specified piping set for R410A. Otherwise, this may result in
broken copper pipes or faults.
A circuit breaker should be installed depending on the mounting site of the unit.
Without a circuit breaker, the danger of electric shock exists.
Do not install the unit near a location where there is flammable gas.
The outdoor unit may catch fire if flammable gas leaks around it. Piping shall be
suitable supported with a maximum spacing of 1m between the supports.
Please ensure smooth flow of water when installing the drain hose. If any failure
is found in the drain path, water drops from the indoor and outdoor units, causing
wet household effects.
Make sure that a single phase 230V power source is used.
The use of other power sources may cause electrical components to overheat
and lead to fire.
PROHIBITION
CONNECT EARTH LINE
PROHIBITION
PROHIBITION
Should abnormal situation arise (like burning smell), please stop operating the
unit and remove plug from the socket or turn off the circuit breaker. Contact your
agent. Fault, short circuit or fire may occur if you continue to operate the unit
under abnormal situation.
Please contact your agent for maintenance.
Improper self maintenance may cause electric shock and fire.
Please contact your agent if you need to remove and reinstall the unit.
Electric shock or fire may occur if you remove and reinstall the unit yourself improperly.
WARNING
PRECAUTIONS DURING INSTALLATION
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
“OFF”
PROHIBITION
Avoid an extended period of direct air flow for your health.
Do not connect the power calbe with an extension cable or do not plug too many
leads of the other electric appliance into the socket where this cable is plugged.
In addition, wire the cable with some allowances to prevent the cable from stretching.
Not doing so will cause an electrical shock, heat generation or fire.
PROHIBITION
Do not put objects like thin rods into the panel of blower and suction side
because the high-speed fan inside may cause danger.
Do not bundle the power cable, pull it, put something on it, heat it, process it, or
put it between things. Breakage of the power cable may result.
Use of a damaged cable may cause an electrical shock or a fire.
PROHIBITION
PROHIBITION
–3–
HSILGNE
– 4 –
WARNING
PRECAUTIONS DURING OPERATION
Do not use any conductor as fuse wire, this could cause fatal accident.
PROHIBITION
During thunder storm, disconnect the plug top or turn off the circuit breaker.
Spray cans and other combustibles should not be located within a meter of the air
outlets of both indoor and outdoor units.
As a spray can’s internal pressure can be increased by hot air, a rupture may result.
“OFF”
CAUTION
PROHIBITION
The product shall be operated under the manufacturer specification and not for
any other intended use.
PROHIBITION
DON’T WET
Do not attempt to operate the unit with wet hands, this could cause fatal accident.
STRICTLY OBSERVE
PRECAUTIONS
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
When operating the unit with burning equipments, regularly ventilate
the room to avoid oxygen insufficiency.
Do not direct the cool air coming out from the air-conditioner panel to
face household heating apparatus as this may affect the working of
apparatus such as the electric kettle, oven etc.
Do not wash the unit with water or place a water container such as a
vase on the indoor unit.
Electrical leakage could be present and cause electric shock.
Please ensure that outdoor mounting frame is always stable, firm and
without defect. If not, the outdoor unit may collapse and cause danger.
Do not place plants or animals directly under the air flow as it is bad for the plants or
animals.
Do not climb on the outdoor unit or put objects on it.
PROHIBITION
PROHIBITION
PROHIBITION
When operating the unit with the door and windows opened, (the room humidity
is always above 80%) and with the air deflector facing down or moving automati-
cally for a long period of time, water will condense on the air deflector and drips
down occasionally. This will wet your furniture. Therefore, do not operate under
such condition for a long time.
If the amount of heat in the room is above the cooling or heating capability of the
unit (for example: more people entering the room, using heating equipments and
etc.), the preset room temperature cannot be achieved.
This appliance especially indoor unit cleaning must be performed by authorized
personnel only. Consult your sales agent.
Using a commercially available detergent or similar can damage the plastic parts
or clog the drain pipe, causing water to drip with potential electric shock hazard.
Do not touch the air outlet, bottom surface and aluminum fin of the outdoor
unit.
You may get hurt.
Do not touch the refrigerant pipe and connecting valve.
Burns may result.
DON’T TOUCH
DON’T TOUCH
This appliance is not intended for use by young children or infirm persons unless they have been
adequately supervised by a responsible person to ensure that they can use this appliance safely.
Young children should be supervised to ensure that they do not play with the appliance.
– 5 –
MODEL NAME AND DIMENSIONS
OUTDOOR UNIT
Air outlet
When “heating” operation is
performed, cool air blows
and when “cooling” or
“dehumidifying” operation is
performed, warm air blows.
Drain hose
Drains the dehumidified water from the indoor unit to the outdoor
during “cooling” or “dehumidifying” operation.
Piping and Wiring
Air inlets (Rear and left sides)
About the outdoor unit:
When “Stop” is selected during operation of the indoor
unit, the fan of the outdoor unit continues turning for
10 to 60 seconds to cool the electric parts down.
In heating operation, condensate or water due to
defrosting will flow.
Do not cover the drain port of the outdoor unit because
such water may freeze in the chilly area.
When the outdoor unit is hung on the ceiling, install
the bush and drain pipe on the drain port and drain
water.
Drain port
(Bottom)
Earth terminal
(Lower section of the side)
MODEL WIDTH (mm) HEIGHT (mm) DEPTH (mm)
RAS-D10EX3, RAS-D14EX3 795 295 198
RAC-D10EX3, RAC-D14EX3 750 548 288
INDOOR UNIT
NAMES AND FUNCTIONS OF EACH PART
Air cleansing filter
Air filter
To prevent dust from coming into the indoor unit.
Front panel
Moveable panel
It will be open when the air conditioner is operate and
close when the air conditioner is not in operation.
(Occasionally it may not be open during the operating
mode)
Horizontal deflector Vertical deflector
(Air Outlet)
Indoor unit indicators
Light indicator showing the operating condition.
Remote controller
Send out operation signal to the indoor unit. So as to
operate the whole unit.
HSILGNE
– 6 –
INDOOR UNIT INDICATORS
FILTER LAMP
When the device is operated for a total of about 200
hours, the FILTER lamp lights to indicate that it is time
to clean the filter.
OPERATION LAMP
This lamp lights during operation.
The OPERATION LAMP flashes in the following cases
during heating.
(1) During preheating
For about 2–3 minutes after starting up.
(2) During defrosting
Defrosting will be performed about once every one
hour when frost forms on the heat exchanger of the
outdoor unit, for 5–10 minutes each time.
SIGNAL RECEIVING PORT
TIMER LAMP
This lamp lights when the timer is working.
OPERATION INDICATOR
TEMPORARY SWITCH
Use this switch to start and stop when the remote controller does not work.
By pressing the temporary switch, the operation is done in previously set operation mode.
When the operation is done using the temporary switch after the power source is turned off and turn on
again, the operation is done in automatic mode.
T
E
M
PO
R
A
R
Y
S
W
I
T
C
H
TEMPORARY
SWITCH
Front panel
Moveable panel
Hand grip point
Hand grip point
Do not hold the moveable panel
when the front panel is in either
opened/closed position.
1. Opening up the front panel
Never try to force open/close the moveable panel manually.
Manually opening or closing the moveable panel may cause breakdowns
. (The moveable panel will
automatically close or open when the power supply is switched on or switched off and whenever the unit
is in operations or has stopped operating.)
CAUTION
Lift the front panel
– 7 –
Minimum Maximum Minimum Maximum
Indoor Dry bulb °C 21 32 20 27
Wet bulb °C 15 23 12 19
Outdoor Dry bulb °C 21 43 2 21
Wet bulb °C 15 26 1 15
Note
gnitaeHgnilooC
Avoid to use the room air conditioner for cooling operation when the outside temperature is below
-10°C (14°F).
The recommended maximum and minimum operating temperatures of the hot and cold sides
should be as below:
2. Closing the Front Panel
1
2
1
CAUTION
!
Pull toward the down direction. Initially press the left and the right sides of the
front panel and finally press the central portion
until you hear a clicking sound.
When front panel is shaky, there is a possibility panel coming off and
falling down.
Do not apply extra force on the front panel when it is opened up in
the upright position.
Also frequent removal of the front panel from the front cover may
cause damage.
HSILGNE
– 8 –
Signal emitting window/transmission sign
Point this window toward the indoor unit when controlling it.
The transmission sign blinks when a signal is sent.
Display
This indicates the room temperature selected, current time, timer status,
function and intensity of circulation selected.
START/STOP button
Press this button to start operation. Press it again to stop operation.
AIR PURIFIER button
Use this button to start air purifying function.
FAN SPEED selector
This determines the fan speed. Every time you press this button, the intensity of
circulation will change from
(AUTO)
to
(HI)
to
(MED)
to
(LOW)
to
(SILENT).
(This button allows selecting the optimal or preferred fan speed for each
operation mode.)
SLEEP button
Use this button to set the sleep timer.
TEMPERATURE buttons
Use these buttons to raise or lower the temperature setting. (Keep pressed, and
the value will change more quickly.)
TIME button
Use this button to set and check the time and date.
RESET button
Press this button after the batteries are replaced or when some irregular
operation is found.
FUNCTION selector
Use this button to select the operating mode. Every time you press it, the mode
will change from (AUTO) to (HEAT) to
(DEHUMIDIFY) to (COOL) and
to (FAN) cyclically.
FAN SPEED selector
AUTO SWING button
TIMER control
Use these buttons to set the timer.
EXTENDED AIRFLOW button
Pushes air out further for an extended airflow
OFF-TIMER button Select the turn OFF time.
ON-TIMER button Select the turn ON time.
RESERVE button Time setting reservation.
CANCEL button Cancel time reservation.
NAMES AND FUNCTIONS OF EACH PART
REMOTE CONTROLLER
This controls the operation of the indoor unit.
The range of control is about 7 meters. If indoor lighting is controlled electronically, the range of
control may be shorter, in some cases, the control signal may not be received.
This unit can be fixed on a wall using the fixture provided. Before fixing it, make sure the indoor unit
can be controlled from the remote controller.
Handle the remote controller with care.
Dropping it or getting it wet may compromise its signal transmission capability.
After new batteries are inserted into the remote controller, the unit will initially require approximately
10 seconds to respond to commands and operate.
Precautions for Use
Do not put the remote controller in the following places.
In direct sunlight
In the vicinity of a heater.
Handle the remote controller carefully. Do not drop it on the floor, and
protect it from water.
Once the outdoor unit stops, it will not restart for about 3 minutes (unless
you turn the power switch off and on or unplug the power cord and plug
it in again).
This is to protect the device and does not indicate a failure.
If you press the FUNCTION selector button during operation, the device
may stop for about 3 minutes for protection.
SILENT
LOW
MED
HI
AUTO
HEAT
DEHUMIDIFY
COOL
FAN
FANSPEED
SLEEPING
STOP (CANCEL)
START (RESERVE)
START/STOP
TIME
TIMER SET
TIMER SELECTOR
ON TIMER
OFF TIMER
AUTO SWING
EXTENDED AIRFLOW
AIR PURIFIER
– 9 –
VARIOUS FUNCTIONS
Auto Restart Control
If there is a power failure, operation will be automatically restarted when the power is resumed with
previous operation mode and airflow direction.
(As the operation is not stopped by remote controller.)
If you intend not to continue the operation when the power is resumed, switch off the power supply.
When you switch on the circuit breaker, the operation will be automatically restarted with previous
operation mode and airflow direction.
Note: 1. If you do not require Auto Restart Control, please consult your sales agent.
2. Auto Restart Control is not available when Timer or Sleep Timer mode is set.
AUTOMATIC OPERATION
The device will automatically determine the mode of operation, HEAT or COOL depending on the
initial room temperature. The selected mode of operation will change when the room temperature
varies.
Press the FUNCTION selector so that the display indicates the
(AUTO) mode of operation.
When AUTO has been selected, the device will automatically
determine the mode of operation, HEAT or COOL depending
on the current room temperature.
When AUTO is first selected, the device will determine the
current room temperature and select the proper operation
mode accordingly.
When the air conditioner has adjusted the room's temperature
to the near preset temperature, it will begin to monitor
operation. If the room temperature subsequently changes,
the air conditioner will once again select the appropriate
operation (heating or cooling) to adjust the temperature to
the preset temperature. The monitoring operation range is
+
3°C relative to the preset temperature.
If the mode automatically selected by the unit is not
satisfactory, manually change the mode setting (heat,
dehumidify, cool or fan).
1
Press the (START/STOP) button.
Operation starts with a beep.
Press the button again to stop operation.
Press the (FAN SPEED) button, AUTO and LOW is available.
As the settings are stored in memory in the remote controller, you
only have to press the
(START/STOP) button next time.
You can raise or lower the temperature setting as necessary by
maximum of 3°C.
Press the temperature button and the temperature
setting will change by 1°C each time.
The preset temperature and the actual room temperature may
vary somewhat depending on conditions.
START
STOP
HSILGNE
Press the (START/STOP) button. Heating operation starts
with a beep. Press the button again to stop operation.
START
STOP
HEATING OPERATION
Use the device for heating when the outdoor temperature is under 21°C.
When it is too warm (over 21°C), the heating function may not work in order to protect the device.
In order to keep reliability of the device, please use this device above -15°C of the outdoor
temperature.
Press the FUNCTION selector so that the display indicates
(HEAT).
1
Set the desired FAN SPEED with the (FAN SPEED) button
(the display indicates the setting).
(AUTO) : The fan speed changes automatically according
to the temperature of the air which blows out.
(HI) : Economical as the room will become warm
quickly.
But you may feel a chill at the beginning.
(MED) : Quiet.
(LOW) : More quiet.
: Ultra quiet.
(SILENT)
2
Set the desired room temperature with the TEMPERATURE
buttons (the display indicates the setting).
The temperature setting and the actual room temperature may
vary somewhat depending on conditions.
3
As the settings are stored in memory in the remote controller, you
only have to press the
(START/STOP) button next time.
Defrosting
Defrosting will be performed about once an hour when frost forms on the heat exchange of the outdoor unit,
for 5~10 minutes each time.
During defrosting operation, the operation lamp blinks in cycle of 3 seconds on and 0.5 second off.
The maximum time for defrosting is 20 minutes.
(If the piping length used is longer than usual, frost will likely to form.)
– 10 –
– 11 –
Dehumidifying Function
When the room temperature is higher than the temperature setting: The device will dehumidify the
room, reducing the room temperature to the preset level.
When the room temperature is lower than the temperature setting: Dehumidifying will be performed
at the temperature setting slightly lower than the current room temperature, regardless of the temperature
setting. The function will stop (the indoor unit will stop emitting air) as soon as the room temperature
becomes lower than the setting temperature.
The preset room temperature may not be reached depending on the number of people present in the
room or other room conditions.
DEHUMIDIFYING OPERATION
Use the device for dehumidifying when the room temperature is over 16°C.
When it is under 15°C, the dehumidifying function will not work.
Set the desired room temperature with the TEMPERATURE
button (the display indicates the setting).
The range of 20-26˚C is recommended as
the room temperature for dehumidifying.
Press the (START/STOP) button. Dehumidifying operation
starts with a beep. Press the button again to stop operation.
2
As the settings are stored in memory in the remote controller, you
only have to press the
(START/STOP) button next time.
START
STOP
Press the FUNCTION selector so that the display indicates
(DEHUMIDIFY).
The FAN SPEED is set at LOW or SILENT.
1
HSILGNE
: Ultra quiet.
(SILENT)
Press the (START/STOP) button. Cooling operation starts
with a beep. Press the button again to stop operation. The cooling
function does not start if the temperature setting is higher than
the current room temperature (even though the (OPERATION)
lamp lights).
The cooling function will start as soon as you set the temperature
below the current room temperature.
START
STOP
COOLING OPERATION
Use the device for cooling when the outdoor temperature is -10 to 42°C.
If humidity is very high (over 80%) indoors, some dew may form on the air outlet grille of the indoor
unit.
Press the FUNCTION selector so that the display indicates
(COOL).
1
Set the desired FAN SPEED with the (FAN SPEED) button
(the display indicates the setting).
(AUTO) : The FAN SPEED is HI at first and varies to MED
automatically when the preset temperature has
been reached.
(HI) : Economical as the room will become cool quickly.
(MED) : Quiet.
(LOW) : More quiet.
2
Set the desired room temperature with the TEMPERATURE
buttons (the display indicates the setting).
The temperature setting and the actual room temperature may
vary somewhat depending on conditions.
3
As the settings are stored in memory in the remote controller, you
only have to press the
(START/STOP) button next time.
– 12 –
– 13 –
2
START
STOP
FAN SPEED (AUTO)
.....
When the AUTO fan speed mode is set in the cooling/heating operation:
For the heating operation
The fan speed will automatically change according to the temperature of
discharged air.
When the difference of room temperature and setting temperature is large,
fan starts to run at HI speed.
When the room temperature reaches setting temperature, fan speed changes
to LOW automatically.
When the difference of room temperature and setting temperature is large,
fan starts to run at HI speed.
After room temperature reaches the preset temperature, the cooling operation,
which changes the fan speed and room temperature to obtain optimum
conditions for natural healthful cooling will be performed.
For the cooling operation
FAN OPERATION
You can use the device simply as an air circulator. Use this function to dry the interior of the indoor
unit at the end of summer.
Press the FUNCTION selector so that the display indicates
(FAN).
Press the (FAN SPEED) button.
(HI) : The strongest air blow.
(MED) : Quiet.
(LOW) : More quiet.
(SILENT) : Ultra quiet.
Press the (START/STOP) button. Fan operation starts with a
beep. Press the button again to stop operation.
EXTENDED AIRFLOW
During operations, press the button to select the various operating modes
that will set the preferred air flow direction and will also adjust the air flow speed
to reach the furthest distance within its range. (During the cooling operating mode,
the air flow direction and air flow speed will return to their original settings after 3
hours of operations).
If the (EXTENDED AIRFLOW) button is pressed while the AUTO SWING
mode is set, the AUTO SWING mode is cancelled and the EXTENDED AIRFLOW
mode is set.
If the (AUTO SWING) button is pressed while the EXTENDED AIRFLOW
mode is set, the EXTENDED AIRFLOW mode is cancelled and the AUTO
SWING mode is set.
If the (EXTENDED AIRFLOW) button is pressed when the horizontal air
deflector stops at your preferred angle, the deflector will change to EXTENDED
AIRFLOW.
As the angle of the horizontal air deflector changes, the air may blow directly
onto the body.
During stop operation, press the button will activate dry function for several
minutes to protect the heat-excharge of indoor unit from mold and bad odour.
1
HSILGNE
– 14 –
AIR PURIFYING OPERATION
Use this function for clean and comfortable air.
Press the button.
Operation start with the display indicates at any mode of
operation.
The indoor unit will generate a negatively-charged ion to
capture the finest and microscopic dust.
Press the button again to cancell the air purifying operation.
1
2
ADJUSTING THE AIR DEFLECTORS
1
Adjustment of the conditioned air in the upward and downward
directions.
The horizontal air deflector is automatically set to the proper angle
suitable for each operation. The deflector can be swung up and
down continuously and also set to the desired angle using the
(AUTO SWING)” button.
In “Cooling” operation, do not keep the horizontal air
deflector swinging for a long time. Some dew may form on
the horizontal air deflector and dew may drop.
CAUTION
2
If the “ (AUTO SWING)” button is pressed once, the horizontal
air deflector swings up and down. If the button is pressed again, the
deflector stops in its current position. Several seconds (about 6
seconds) may be required before the deflector starts to move.
Use the horizontal air deflector within the adjusting range
shown in the right.
When the operation is stopped, the horizontal air deflector
moves and stops at the position where the air outlet closes.
Adjustment of the conditioned air to the left and right.
Hold the vertical air deflector as shown in the figure and adjust
the conditioned air to the left and right.
Vertical
Vertical
about 15
about 60
about 45
about 30
When cooling,
dehumidifying
When heating
– 15 –
HOW TO SET THE SLEEP TIMER
1
Set the ON-timer.
Set the current time at first if it is not set before (see the pages for setting
the current time). Press the (SLEEP) button, and the display changes as
shown below.
Mode
Sleep timer
Indication
1 hour 2 hours 3 hours 7 hours
Sleep timer off
Sleep Timer: The device will continue working for the designated
number of hours and then turn off.
Point the signal window of the remote controller toward the indoor
unit, and press the SLEEP button.
The timer information will be displayed on the remote controller.
The TIMER lamp lights with a beep from the indoor unit. When the
sleep timer has been set, the display indicates the turn-off time.
Example: If you set 3 hours sleep
time at 11:38 p.m., the turn-off
time is 2:38 a.m.
2
Press the (SLEEP) button and set the sleep timer.
The device will be turned off by the sleep
timer and turned on by on-timer.
How to Cancel Reservation
Point the signal window of the remote controller toward the indoor unit, and press the (CANCEL)
button.
The (RESERVED) sign goes out with a beep and the (TIMER) lamp turns off on the indoor unit.
For heating:
In this case, the device will turn off
in 2 hours (at 1:38 a.m.) and it will
be turned on 6:00 next morning.
H
AM
H
AM
AM
Sleep
timer
Start
SLEEP
HSILGNE
– 16 –
HOW TO SET THE TIMER
ON/OFF-Timer
The device will turn on (off) and off
(on) at the designated times.
The switching occurs first at the
preset time that comes earlier.
The arrow mark appearing on the
display indicates the sequence of
switching operations.
1
Press the (ON-OFF)
button so that the (OFF)
mark blinks.
OFF-Timer
You can set the device to turn off
at the present time.
After you change the
batteries;
How to Cancel Reservation
Point the signal window of the remote controller toward the indoor unit, and press the (CANCEL)
button.
The (RESERVED) sign goes out with a beep and the (TIMER) lamp turns off on the indoor unit.
1
Set the (TIME) button.
1
Press the (OFF-TIMER)
button. The (OFF) mark blinks
on the display.
1
Press the (ON-TIMER)
button the (ON) mark blinks
on the display.
2
Set the turn-off time
with the TIMER control
button.
Press the (RESERVE)
button.
3
Press the (ON-
TIMER) button so that the
(OFF) mark lights and
the (ON) mark blinks.
NOTE
You can set only one of the OFF-timer,
ON-timer and ON/OFF-timer.
ON-Timer
Time
The device will turn on
at the designated times.
AM
PM
STOP
Start
AM
Start
Stop
AM
Start Stop
PM
PM
AM
PM
TIME
OFF TIMER
ON TIMER
RESERVE
CANCEL
– 17
HSILGNE
3
Point the signal window of the remote controller toward the indoor unit, and
press the (RESERVE) button.
The
(OFF) mark starts lighting instead of flashing and the sign (RESERVED)
lights. A beep occurs and the (TIMER) lamp lights on the indoor unit.
The time indication will disappear
automatically in 10 second.
To check the current time setting,
press the (TIME) button twice.
The setting of the current time is
now complete.
The timer may be used in three ways: off-timer, on-timer, and ON/OFF (OFF/ON)-timer. Set the
current time at first because it serves as a reference.
As the time settings are stored in memory in the remote controller, you only have to press the
(RESERVE) button in order to use the same settings next time.
2
Press the
(TIME) button.
3
Set the current time with the
TIMER control button.
Example: The current time is 1:30 p.m.
2
Set the turn-off time with the
TIMER control button.
The setting of turn-off time is now complete.
Example: The device will turn off at 11:00p.m.
Example:
The device will turn on at 7:00 a.m.
The setting of the turn-on time is now complete.
4
Set the turn-on time with the
TIMER control button.
5
Point the signal window of the remote controller toward the indoor unit, and
press the (RESERVE) button.
The (ON) mark starts lighting instead of flashing and the
(RESERVED)
sign lights. A beep occurs and the
(TIMER) lamp lights on the indoor unit.
3
Point the signal window of the remote controller toward the indoor unit, and
press the (RESERVE) button.
The
(ON) mark starts lighting instead of flashing and the (RESERVED)
sign lights. A beep occurs and the (TIMER) lamp lights on the indoor unit.
2
Set the turn-on time with the
TIMER control button.
Example:
The device will turn off at 10:30 p.m. and it will be turned on
at 7:00 a.m.
The settings of the turn-on/off times are now complete.
4
Press the (TIME) button again.
The time indication starts lighting
instead of flashing.
PM
AM
PM
PM
PM
PM
PM
PM
PM
PM
AM
AM
AM
AM
PM
AM
PM
PM
AM
PM
AM
– 18 –
HOW TO EXCHANGE THE BATTERIES IN THE REMOTE CONTROLLER
1
Remove the cover as shown in the figure and take out the
old batteries.
2
Install the new batteries.
The direction of the batteries should match the marks in the
case.
1. Do not use new and old batteries, or different kinds of batteries
together.
2. Take out the batteries when you do not use the remote controller
for 2 or 3 months.
CAUTION
!
Push and pull to the
direction of arrow
CIRCUIT BREAKER
When you do not use the room air conditioner, set the circuit breaker to “OFF”.
TEMPORARY SWITCH
If the remote controller does not work due to battery failure, press this switch to start and stop operation.
This temporary operation will be at the setting made most recently. (The unit will immediately go into
automatic operation once power is switched on.)
– 19 –
Suitable Room Temperature Install curtain or blinds
Ventilation Effective Usage Of Timer
Do Not Forget To Clean The Air Filter
Please Adjust Suitable Temperature
For Baby And Children
Warning
Freezing temperature
is bad for health and a
waste of electric power.
!
It is possible to
reduce heat
entering the
room through
windows.
At night, please use the “OFF or ON timer
operation mode”, together with your wake up
time in the morning. This will enable you to
enjoy a comfortable room temperature. Please
use the timer effectively.
Dusty air filter will reduce the air volume and
the cooling efficiency. To prevent from wasting
electric energy, please clean the filter every 2
weeks.
Please pay attention to the room temperature
and air flow direction when operating the unit
for baby, children and old folks who have
difficulty in movement.
Caution
Do not close the room for a long period of
time. Occasionally open the door and windows
to allow the
entrance of
fresh air.
!
THE IDEAL WAYS OF OPERATION
HSILGNE
– 20 –
FOR USER’S INFORMATION
The Air Conditioner And The Heat Source In The Room
Not Operating For A Long Time
When Lightning Occurs
Caution
If the amount of heat in the room is above the cooling
capability of the air conditioner (for example: more
people entering the room, using heating equipments
and etc.), the preset room temperature cannot be
achieved.
!
When the indoor unit is not to be used for a long
period of time, please switch off the power from the
mains. If the power from mains remains “ON”, the
indoor unit still consumes about 8W in the operation
control circuit even if it is in “OFF” mode.
Warning
To protect the whole unit during lightning, please
stop operating the unit and remove the plug from the
socket.
!
OFF
Interference From Electrical Products
Caution
To avoid noise interference, please place the indoor
unit and its remote controller at least 1m away from
electrical products.
!
Inverter-type
fluorescent
lamp.
To prevent
interference,
place at least
1m away.
TV
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26

Hitachi RAC-D14EX3 Manuale utente

Categoria
Condizionatori d'aria a sistema split
Tipo
Manuale utente
Questo manuale è adatto anche per

in altre lingue