7
When the weather station is connected to the batteries on the first time, after detecting
the temperature/humidity, it will automatically enter the weather setting mode, press the
Snooze button to exit or automatically exit after 20S, enter the RF receiving for 3 minutes,
and then enter the receiving RCC for 7 minutes.
Generally, the outdoor sensor will connect with the base unit automatically. If it doesn’t
connect, please follow below steps to set:
• Ensure that the weather station is in the same channels with the outdoor sensor.
• Long press the CH button on the base unit to search signal from the outdoor sensor.
• The sensor receiving icon will flash when searching for the signal.
• After the sensor is connected, the icon will become stable.
Note: After replacing the sensor battery, you need to press and hold the CH button of the
station to receive again.
Reception RCC
After successful reception of the signal for the outdoor sensor, the reception of the DCF77
time signal will begin and the radio control indicator will blink on the display next to the
time. This process can take from 7 minutes. All buttons except the SNOOZE/LIGHT and
buttons are disabled during the reception process. When the signal is received, the RCC
tower part mark is static, and the arc antenna flashes at a frequency of 1Hz; When the signal
is weak and the correct signal cannot be distinguished, the tower part flashes at 1Hz, and
the arc antenna part does not display.
1. When the receiving signal is successful, the RCC receiving sign will be fully displayed and
the receiving state will be exited;
2. During the receiving process, single pressing the " " button will exit the RCC receiving
state, except that single pressing the "SNOOZE/LIGHT" button can light up the backlight
function, other buttons have no function;
3. Automatic reception: every morning (current time zone)01:00, 02:00, 03:00 to force
reception to 04:00, 05:00 to choose to receive 05:00, regardless of whether the reception is
successful or not, it will no longer be received on that day, and the RCC reception time is 7
minutes;
4. If the receiving signal fails on the same day, the next receiving time will be 01:00 the next
day;
5. In the process of receiving RCC, when encountering the ALARM alarm, it will exit the RCC
reception and switch to the alarm