WisyCom MTP40 Manuale utente

Tipo
Manuale utente
MTP40 User Manual
Wideband Wireless
Professional Pocket
Transmitter
SN: ________________
Rev.04 (rif. FW 110.0P)
Date: 16 July 2014
MTP40
E-series
MTP40 User Manual
Rev.04
2
MTP40 User Manual
Rev.04
3
INTRODUCTION
MTP40 is an extremely small and light pocket transmitter especially designed for professional
wireless microphone applications”
Very easy and quick to use thanks to OLED display, dedicated buttons and a joggle selector.
MTP40 benefits also of the latest Wisycom RF technology along with an enhanced robustness
against noise and inter-modulation.
Fig. 1
Switch to enable wireless transmission, it
also indicates the battery status and
peak/mute operation (with PTT)
In order to allow front visibility same colour
information on (1) is replicated with this LED
Oled display for transmitter setup
<ch>, <gain> and 3 positions <selector>
Battery holder
Cover (to open push side buttons)
1. Fig. 2
Turn on wireless:
Move the Wireless power switch in
“I” position: switch becomes green
(red indicate PTT/MUTE).
A green blinking gives you
indications on battery status.
1
Open MIC Body:
Push the side buttons and flip down the cover, to access
internal setup controls and batteries.
Turn on display:
Push <select switch> and hold it.
Front LED color is the same
of power switch.
2
3
5
6
4
MTP40 User Manual
Rev.04
4
SAFETY INSTRUCTION
Read this safety instruction and the manual first
Follow all instructions and information.
Do not lose this manual.
Do not use this apparatus under the rain or near the water.
Do not install the apparatus near heaters or in hot environments, do not use outside the
operating temperature range.
Do not open the apparatus, only qualified service technician are enabled to operate on it.
The apparatus needs servicing when it is not properly working or is damaged by liquids,
moisture or other objects are fallen in the apparatus.
Use only accessories or replacement parts authorized or specified by the manufacturer.
Clean the apparatus only with dry cloths, do not use liquids.
Report the serial number and the purchasing date in front of the manual. It is needed to
have proper replacement parts or accessories from the manufacturer.
When replacement parts are needed, use only replacement parts authorized from the
manufacturer. Substitution with not authorized parts could result in electric shock,
hazards or fire.
Keep attention on all the labels with warnings or hazards on the apparatus.
LED INDICATIONS
Led indication with bi-colour led (red & green) on wireless power switch (1) and in front led (2):
- Wireless transmission status: green when RF transmission power is on.
- Battery status: green steady, slowly blinking (< 25%), quickly blinking (<12%).
- Modulation peek (if activated): red.
- Ptt status: red if active (push to talk “pushed”).
BATTERIES
MTP40 is working with 2 AA alkaline or NiMH batteries (select correct type on setup controls).
Battery status can be checked on internal OLED display or looking to LED status on power
switch (see 1.1).
BATTERY SUBSTITUTION
Open transmitter cover and insert batteries following polarity indicated.
Attention: always replace both the batteries
MTP40 User Manual
Rev.04
5
POWERING UP
Move the wireless power switch (see Fig. 1) in “I” position to activate wireless transmission: a
green LED lights up (blinking when battery is low!)
SETUP CONTROL
Open transmitter Body to access the “display and controls” area (Fig. 3):
A. Graphics Display (OLED)
B. Channel selection buttons (ch)
C. MIC gain setup buttons (gain)
D. 3 position selector (up / down / click)
Fig. 3
OLED POWER UP (OLED IS IN OFF CONDITION)
Pushing down selector (click), oled turns on. A first menu with serial NO and brand logo is
displayed, then <status> menu enters automatically.
Pushing and holding selector (click) > 2 sec, serial NO menu is displayed till (-/+) is selected.
OLED POWER DOWN (OLED IS IN ON CONDITION)
Pushing and holding selector (click) > 2 sec, display is turned off.
Display turns off automatically after 15 sec, unless in <IRDA> menu or in <AUDIO> menu (with
audio level < 5% from nominal).
+
-
CLICK
A
B
C
D
MTP40 User Manual
Rev.04
6
DISPLAY MENU
Setup menu are accessed in sequence:
MENU
STATUS
PRESET
Current
Load from
FACTORY/USER/PRESET1/2/3/4/5/6/7/8
Save to
USER
TUNING
CH 00-59
GR 00-39
Freq
1: 470.000÷640.000
2: 566.000÷798.000
3: 510.000÷698.000
Name
AUDIO
AF In Gain
-20÷40 dsB (1dB step)
HPass Filter
flat/60/80/120/170/250/400Hz
MIC
Mode
2 wires/2wires+bias/3 wires/
2wires&pha/2 w + bias&pha
Phase
0/180
PTT
Disable/Normal/Muting/No Data
RF Power
Power
High/Low
NOISE RED
ENC-Wisy/ENR-Wisy
OTHERS
Led Light 0-16
Led Mode
None/ModPeak/PTT
Battery Alkaline/NiMH
IRDA
Lock
Preset parameters
MTP40 User Manual
Rev.04
7
+
-
CLICK
Using <+/-> selector all menus can be accessed in sequence, push <click> to enter edit mode:
<+/-> to setup field
<click> again to confirm changes and exit.
exit without confirmation if no button is pressed after a few seconds time out.
<START UP> menu
These menus are displayed during power up for few seconds.
First one gives information of antenna to be used. The
number displayed is the center-band of the antenna to
be used.
The second menu gives indication on product:
- product id (MTP40),
- a number which identify the working band
1
470-640
2
566-798
3
510-698
- a number which identify the hardware version
- the firmware release (110.0P),
- the band in extended format and
- the serial number.
Keep selector pushed to hold this menu!
<STATUS> menu
This is the first menu displayed after power up.
Major info are displayed:
- Current channel/group (i.e. CH:00 GR:08)
- Current frequency (i.e. 566.075 MHz)
- Mic gain (i.e. AF: -04 dB) and high pass filter (i.e.
HP:60 Hz)
- “RF H” or “RF L” on top right if RF transmission is
on at high or low power respectively
- On bottom battery bar is displayed
MTP40 User Manual
Rev.04
8
<PRESET> menu
This menu can be entered by scrolling selector, or pushing at the same time both quick
channel setup buttons (<ch> & <gain>).
MTP40 can recall configuration presets. “FACTORY” recall
the Wisycom factory configuration. “USER” recall the
user configuration (the transmitter configuration is
copied into the USER using the “save to” submenu). All
“USER” menus are not locked by default,
thus this is quick way to unlock features!
The other 8 configuration presets are user programmable thru the infrared and the
PC interface (using the programmer UPK 300 or the receiver MRK950/MRK960).
All parameters can be “left unchanged”, “changed” or “changed and lock”,
allowing a very flexible way to pre-program MTP40 configuration.
<TUNING> menu
This menu can be entered by scrolling selector or using quick channel setup buttons (<ch>).
In this menu current channel/group and frequencies can
be setup. Use the selector to change values (<+/->) and
<click> to confirm.
Sync group is a quick self-settable channel synchronized
by receiver.
<AUDIO> menu
This menu can be entered by scrolling selector or using quick gain setup buttons (<gain>).
AF In Gain” setup to tune audio input sensitivity:
To help proper audio gain setting, an audio
bar is supplied with peak hold bar)
indicating the headroom to audio peak
(0 dB).
AF gain is shown with 2 different unit of
measurements dB (gain in dB of MTP40 amplifiers) or
in dBu peak.
HighPass Filter” applies different audio HP filter:
Flat / 60Hz / 120Hz / 170Hz / 250Hz / 400Hz.
Use the selector to change values (<+/->) and <click> to
confirm.
MTP40 User Manual
Rev.04
9
<MIC> menu
This menu can be entered by scrolling selector.
Following Mic mode can be setup (for LEMO option)
-2 wires: (PTT is possible) for external audio input
-2 wires + bias: (PTT is possible) for most 2 wires MIC
-3 wires: (no PTT) for most 3 wires MIC
-2 wires & pha: to connect a wired mic thru a 48V
adapter (PHA48)
-2 wires+bias & pha: Allow to connect a ‘2 wires + bias’ MIC
or a ‘2 wires & phantom’ MIC (with PHA48)
Additional field to setup
- Phase: is audio phase can be 0/180 deg.
- PTT operation mode: Normal (pushing make a
remote switch)/Muting (pushing mute the
audio)
Use the selector to change values (<+/->) and <click> to
confirm.
NOTE: For DPA option (2 pin microdot audio connector), even if the MIC mode menu allows to
set one of the 5 MIC modes, only 2 wires or 2 wires+bias mode are possible.
<RF POWER> menu
This menu can be entered by scrolling selector.
RF power can be setup to High (50 mW ERP) or Low (10
mW ERP).
Use the selector to change values (<+/->) and <click> to
confirm.
<NOISE RED> menu
This menu can be entered by scrolling selector.
MTP40 supports 2 different type of “Companding
systems”
ENR: designed for maximum noise reduction
ENC: designed for maximum audio fidelity (use this in
case of special vocal application or to remote
instruments)
MTP40 User Manual
Rev.04
10
<OTHERS> menu
This menu can be entered by scrolling selector.
Power switch green LED brightness can be setup LED
light. Modulation peak LED on power switch (become
RED when audio get close to saturation) can be
enabled/disabled.
Battery type can be setup in Alkaline or NiMH.
<IRDA> menu
This menu can be entered by scrolling selector.
While is this menu MIC can be connected to IRDA for
setup or firmware upgrades.
NOTE: while in this menu display is not automatically
turned off.
<LOCK> menu
This menu can be entered by scrolling selector.
Long pressing (2 sec.) selector button (click) it locks
MTP40 in transmission mode.
To unlock, long pressing (2 sec.) selector button again.
<BOOTLOAD> menu
This menu can be entered only turning on the transmitter while pushing at the same time both
quick channel setup buttons (<ch> & <gain>).
Device is forced in bootloader mode to allow FIRMWARE
UPDATE.
MTP40 User Manual
Rev.04
11
The following table sums up which parameters can be set and the related range settings.
MENU
PARAMETER
MEANING
RANGE SETTINGS
TUNING
CH
Channel
0 ÷ 59
GR
Group
0 ÷ 39 + SYNC GROUP
Freq
Frequency
depends on the MTP40 Model:
1 470-640
2 566-798
3 510-698
AUDIO
AF In Gain
Gain of the
audio signal
depends on the mic mode setting
(ex. -40dB ÷ 40dB step of 1 dB)
High Pass Filter
High Pass filter
Flat/60/80/120/170/250/400 Hz
MIC
Mode
MIC type
’2 wires’
‘2 wires + bias’
‘3 wires’
‘2 wires & phantom’
‘2 wires + bias & phantom’
Phase
Audio signal
phase
0° or 180°
PTT Mode
It defines how
and what
information the
transmitter has
to send
Disable:when the PTT button is pushed, nothing
happen. (the transmitter sends AF+Tone
squelch)
Normal: when the PTT button is pushed, the
transmitter send a different RF signal. According
to the receiver configuration the audio can be
enabled/disable on LINE (and/or COM).
Muting: the transmitter doesn’t send the audio.
The voice is cut, it doesn’t enter to the
microphone
No Data: the transmitter sends neither tone
squelch nor battery data.
RF POWER
RF Power
RF Power
High (50 mW ERP) or
Low (10 mW ERP)
NOISE RED.
NRSYS
Noise reduction
ENR: Wisycom Extended-NR,noise optimized
ENC: Wisycom Extended-NC,voice optimized
OTHERS
Led Light
Power switch
green
brightness
0 ÷ 16
Led Mode
It defines when
the power
switch led (see
Fig. 3) has to
become RED
None: never
ModPeak: when audio get close to saturation
PTT: when the PTT button is pushed
Battery
Battery type
Alkaline or NiMH
MTP40 User Manual
Rev.04
12
MIC Mode setting (only for LEMO option):
MIC Mode:
Pin out
Gain
PTT
Led Mode
’2 wires’:
1=GND
3=AF
-40/40 dB
Disable
Normal
Muting
No data
None
Mod. Peak
PTT
‘2 wires + bias’:
1=GND
3=AF+5.5V
-20/40 dB
Disable
Normal
Muting
No data
None
Mod. peak
PTT
‘3 wires’:
1=GND
2=5.5V
3=AF
-40/40 dB
Disable
No data
None
Mod. peak
‘2 wires &
phantom’:
1=GND
2=3.1V (power for
PHA48)
3=AF
-40/40 dB
Disable
No data
None
Mod. peak
‘2 wires + bias &
phantom’:
1=GND
2=3. 1V (power for
PHA48)
3=AF+5,5V
-20/40 dB
Disable
No data
None
Mod. peak
MTP40 User Manual
Rev.04
13
ACCESSORIES AND PARTS
AWF30-B1-507
For MTP40-X-X1
Band 470 ÷ 547 MHz
Antenna Code label 507
AWF30-B1-590
For MTP40-X-X1
Band 547 ÷ 640 MHz
Antenna Code label 590
AWF30-B2-616
For MTP40-X-X2
Band 566 ÷ 672 MHz
Antenna Code label 616
AWF30-B2-732
For MTP40-X-X2
Band 672 ÷ 798 MHz
Antenna Code label 732
AWF30-B3-552
For MTP40-X-X3
Band 510 ÷ 595 MHz
Antenna Code label 552
AWF30-B3-646
For MTP40-X-X3
Band 595 ÷ 698 MHz
Antenna Code label 646
CAL48
Cable to connect an MTP30 (with option /PHA) or MTP40/40S
to a PHA48 to use microphone with XL3/48V connection
CAL120
AF cable (120cm), LEMO 3pole / XLR-3F connectors
PHA48
Plug-on for XLR3 Mic with 48V Phantom power.
To be used with CAL48 (connected to an MTP30/40/40S)
NEW REV2 with 4mA Phantom current!
ADT40
Power Adapter for MTP30/40/40S.
Power input: 9-18V DC feeding (internal switching regulation).
variants:
ADT40: without connector (pigtail)
(Shield= GND , Blue-Red= Vdc)
ADT40X: with XLR-4pin power connector
ADT40H: with Hirose-4pin power connector
NOTE: MTP30/40/40S must have ADT option to pass thru cable
UPK300E
Infrared programming kit
(interface + software) USB interface
Antenna Code
label
MTP40 User Manual
Rev.04
14
WISYCOM IR PROGRAMMER (VER. 1.3.1.1 AND ABOVE)
Wisycom IR Programmer allows to read, modify and update the MTP40 device configuration.
It is necessary to
install Wisycom IR Programmer (version 1.3.1.1 or above)
WARNING: If it is the first installation and Wisycom USB driver has not already
installed in the PC, install the USB driver (run C:\Program Files
(x86)\Wisycom\MTP&MTH Infrared Programmer (TX)\Drivers\ DriverInstaller.exe)
connected the programmer PK300 or the receiver MRK950/MRK960 to the PC thru
USB connection
run the program
enable the IRDA communication on the transmitter (see IRDA menu)
NOTE: Wisycom IR Programmer doesn’t work whit MRK950/MRK960 if it is connected to the
PC using an ethernet cable.
The Wisycom IR Programmer’s window is divided in 4 parts (see Fig. 5):
Interface and Device panel contains all the major information of the connected device
Current Settings panel shows the current configuration. Thanks the PRESET panel, a
previous saved configuration can be chosen and loaded like current setting.
Tuning Frequencies panel allows to handle Groups, Channels and Frequencies
Presets panel allows to read, change and save different configurations
Figure 5: Wisycom IR Programmer’s window
MTP40 User Manual
Rev.04
15
10 different configurations are available:
FACTORY configuration is a locked configuration: no parameter can be changed.
USER configuration is the only configuration that can be saved using the OLED display (see
<PRESET> menu). Note: It is not possible to change the name of this configuration.
Other 8 configurations where the user can change both the name and the values of all
parameters.
INTERFACE AND DEVICE PANEL
At the beginning, the program checks which IR devices are detected and they appears on the
Interface panel.
The user has to select the device and push <connect> button in order to open the
communication with the IR device. A picture on the top in the Interface panel help the user in
this selection showing the type of devices detected. During this process the “IR activity” led
blinks to indicate that the program wait connection’s answer from the IR device.
A successful connection is signaled with the “interface connection” green led, while a failed
connection is signaled with the “communication error” led.
Once a supported device is found, the software automatically reads all the data related to the
remote configuration, as well as the frequencies that are pre-programmed.
Firstly, in order to avoid unwanted operation, no parameters can be changes and the EDIT
button, presents on the bottom of Device panel, is yellow and set to LOCKED state. Pushing
the EDIT button, it becomes grey and sets to UNLOCKED state to indicate that the
configurations can be modified.
CURRENT SETTINGS PANEL
In the Current Settings panel the user can
with Preset panel → load one of the 10 available configurations
with other panels → modify all the configuration’s parameters (the same that are
changeable in the OLED display). Each parameter can be locked clicking the related
lock button, so the set value can not be changed next using the OLED display.
ATTENTION: All the modifies applied to the Current Settings panel are instantaneous: they are
applied directly to the device and save in its memory but no saved in the preset configuration.
MTP40 User Manual
Rev.04
16
TUNING FREQUENCIES PANEL
With the Tuning Frequencies panel the user can select a frequencies group (0÷39) and for each
one execute the following operations:
- modify the Group’s Name
- lock and/or hidden the group
- for each channel (0 ÷59) of the selected group: change the frequency value and the
related status (locked/hidden) (in the center grid frequency)
The SAVE button, at the top of the
panel, save the changes of the group
selected (name group, lock/hidden
group).
To change a frequency
value for a specific
channel: double click
on the grid frequency
panel (row=channel’s
number), insert the
new frequency value
and press OK button.
To lock/hide a specific
channel, double click on the
grid frequency panel.
NOTE: keeping pressed the CTRL button on the keyboard and clicking the wanted
channel/group shown on the frequencies grid, the tuning process is executed. It is equivalent
to configure the Tuning in the Current Settings panel but it is easier. The device is re-tuned
immediately, so be sure that the RF power is turned off while changing frequencies with other
RF systems in use around you!
If the currently tuned channel is on the same group that is listed on the grid, the background
color of the related cell (channel) on the grid becomes yellow.
MTP40 User Manual
Rev.04
17
Using the LOAD/SAVE button, at the bottom of the panel, it is possible to load/save the
frequencies for the selected group from/to a .wdf file. To save the frequencies of all the groups
click to the related button above. The legacy option save the channels without the hidden/lock
info.
MTP40 User Manual
Rev.04
18
PRESETS PANEL
The Preset panel allows to manage all the 10s available configurations.
For each configuration it is possible to set the name and all the parameters value except for
FACTORY and USER configurations (see table below).
PRESETS:
NAME*
LOCK/DON’T CARE
PARAMETERS
VALUE
FACTORY
USER
OTHERS
√=change is allowed
* Be careful to write a meaningful name for the preset because the name will appear on the
settings list of the device menu! Please, avoid empty names.
If a parameter is “locked”, it cannot be modified by device menu (using OLED display), while if
“don’t care” propriety is active, when the user load the configuration, the parameter’s value
doesn’t changed.
ATTENTION: Changes are applied only after a “save” action.
NOTE: “a trick” In case of the user have a locked parameter and he is in great need for modify
it, he can save the configuration to USER configuration by OLED (see PRESET menu) and then
load the USER configuration (in this way all the parameters have the lock propriety disable and
the user can modify all the parameters).
FILE MENU
Using a file menu at the top left of
the panel it is possible to load/save
all the configuration values of the
device to/from a .wcf file (Wisycom
Configuration File).
Save a .wcf file
With an infrared device correctly connected, select File->Save User Configuration and select
the destination file.
Load a .wcf file
To load a user configuration select File->Load User Configuration and select a previously saved
data file; a form will be shown, where it's possible to select which data has to be restored and
which skipped. This allow the user to load a particular configuration while keeping other data.
MTP40 User Manual
Rev.04
19
TECHNICAL SPECIFICATIONS
Switchable
channels
2400 allocated by 40 groups of 60 channels (in specific frequency range), quickly
selectable with dedicated buttons
Switching
window
Up to 90 MHz, depending on band (see below code table)
Frequencies
Quartz PLL frequency synthesizer circuit (25 kHz step)
Frequency
stability
± 2,5 ppm (in the rated temperature range)
Temp.range
-10 ÷ +55 °C
Max RF power
50 mW (ERP) when high power selected
10 mW (ERP) when low power selected
Spurious
emissions
< 2 nW
Modulation
wideband FM, with 50 µs pre-emphasis
Nominal
deviation
±40 kHz (Peak deviation = ±56 kHz)
Telemetry
feature
MTP40 transmits also a digitally modulated sub-carrier, suitable for:
tone-squelch operating
remote battery monitoring
optional PTT (push to talk) operation
AF input
connector
LEMO option
Configurable on ‘mic’ display menu in 5 options:
’2 wires’:
‘2 wires + bias’:
‘3 wires:
‘2 wires & phantom’
‘2 wires + bias & phantom’:
gain selectable -40 ÷ +40 (-54 dBu ÷ +26 dBu peak), no bias voltage
gain selectable -20 ÷ +40 (-54 dBu ÷ + 6 dBu peak), 5.5 V on 4k7 bias supply
gain selectable -40 ÷ +40 (-54 dBu ÷ +26 dBu peak)
gain selectable -40 ÷ +40 (-54 dBu ÷ +26 dBu peak),
gain selectable -20 ÷ +40,(-54 dBu ÷ + 6 dBu peak), 5.5 V on 4k7 bias supply
AF input level
80 dB adjustable range from -60 dBu (775 uV) to 26 dBu (15.5 V) at peak deviation (1
kHz), adjustable in 1 dB steps
Max. input level
+26 dBu (15.5 V) at clipping, +20 dBu (7.75 V) at nominal level
Noise-Reduction
ENR (Wisycom Extended-NR), with independent Attack- and Recovery-time, noise
optimized
ENC (Wisycom Extended-NC), with independent Attack- and Recovery-time, voice
optimized & with reduced pre-emphasys
AF bandwidth
45 Hz ÷ 21 KHz (3dB)
55 Hz ÷ 20 KHz (1dB)
Distortion
< 0.3 % (0.15 % typ.)
Signal-to-noise
ratio
typ. 115 dB (A)
rms
with 40 kHz deviation
typ. 121 dB (A)
rms
with 56 kHz deviation
Led
Led indication with bicolor led (red & green) on wireless power switch:
Wireless transmission status:
GREEN on/off
Battery lifetime status: GREEN - steady (> 25%)
- slowly blinking (< 25%) - quickly blinking (<12%)
Modulation peek (if activated): RED
Ptt status: RED if active
Display
High contrast OLED (Organic light-emitting diode) bicolor display (96 x 36 pixels)
8 step battery lifetime indication: 7 bars (100%-87%-75%-63-50%-38%-25%) andempty
bar” quickly blinking (12% remaining)
PTT function
Pin 3 of the AF connector can be setup to an external push button
Power supply
2 AA size batteries (Alkaline, rechargeable NiMH)
MTP40 User Manual
Rev.04
20
MTP40 Battery
life
(2 AA alkaline)
approx. 10 hours @ 50mW continuous working
approx. 14 hours @ 10mW continuous working
Dimensions
73 x 61 x 17.5 mm (Height-Width-Depth) without clip
Weight
Approx. 80 g. without batteries (120g with batt.)
Note: MTP40 transmitter complies with ETS 300 422
OPTION CODE MTP40-X-YZ :
AUDIO CONNECTOR (-X)
L 3 PIN LEMO CONNECTOR
(use FVB.00.303.NLAE24 with on Mic)
D 2 PIN MICRODOT CONNECTOR
COLOR (-Y)
B body color "matt black"
Ex. MTP40-L-B1 is 3 pins LEMO connector , matt black color and 470-640 Mhz frequency range
FREQUENCY RANGE (-Z)
1 470-640 MHz
2 566-798 MHz
3 510-698 MHz
GND
5.5V
(3 wires)
AF
AF + 5.5V (2 wires)
Option L Lemo Conn.
MTP40
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

WisyCom MTP40 Manuale utente

Tipo
Manuale utente

in altre lingue