Yamaha MDX-E300 Manuale utente

Categoria
Lettori minidisc
Tipo
Manuale utente
MDX-E300
OWNER’S MANUAL
MODE D’EMPLOI
BEDIENUNGSANLEITUNG
BRUKSANVISNING
MANUALE DI ISTRUZIONI
MANUAL DE INSTRUCCIONES
GEBRUIKSAANWIJZING
Minidisc Recorder
Lecteur Enregistreur de Minidisc
GB
YAMAHA ELECTRONICS CORPORATION, USA 6660 ORANGETHORPE AVE., BUENA PARK, CALIF. 90620, U.S.A.
YAMAHA CANADA MUSIC LTD. 135 MILNER AVE., SCARBOROUGH, ONTARIO M1S 3R1, CANADA
YAMAHA ELECTRONIK EUROPA G.m.b.H. SIEMENSSTR. 22-34, 25462 RELLINGEN BEI HAMBURG, F.R. OF GERMANY
YAMAHA ELECTRONIQUE FRANCE S.A. RUE AMBROISE CROIZAT BP70 CROISSY-BEAUBOURG 77312 MARNE-LA-VALLEE CEDEX02, FRANCE
YAMAHA ELECTRONICS (UK) LTD. YAMAHA HOUSE, 200 RICKMANSWORTH ROAD WATFORD, HERTS WD1 7JS, ENGLAND
YAMAHA SCANDINAVIA A.B. J A WETTERGRENS GATA 1, BOX 30053, 400 43 VÄSTRA FRÖLUNDA, SWEDEN
YAMAHA MUSIC AUSTRALIA PTY, LTD. 17-33 MARKET ST., SOUTH MELBOURNE, 3205 VIC., AUSTRALIA
Printed in Malaysia V914100
MDX-E300
CAUTION – VISIBLE AND
/
OR INVISIBLE LASER RADIATION
WHEN OPEN. AVOID EXPOSURE TO BEAM.
VARNING – SYNLIG OCH
/
ELLER OSYNLIG LASERSTRÅLNING NÄR
DENNA DEL ÄR ÖPPNAD. STRÅLEN ÄR FARLIG.
VARO ! AVATTAESSA OLET ALTTIINA NÄKYVÄLLE JA
/
TAI
NÄKYMÄTÖMÄLLE LASERSÄTEILYLLE.
ÄLÄ KATSO SÄTEESEEN.
VARNING – SYNLIG OCH
/
ELLER OSYNLIG LASERSTRÅLNING NÄR
DENNA DEL ÄR ÖPPNAD. BETRAKTA EJ STRÅLEN.
VORSICHT ! SICHTBARE UND
/
ODER UNSICHTBARE
LASERSTRAHLUNG WENN ABDECKUNG GEÖFFNET.
NICHT DEM STRAHL AUSSETZEN.
CLASS 1 LASER PRODUCT
LASER KLASSE 1 PRODUKT
LUOKAN 1 LASERLAITE
KLASS 1 LASER APPARAT
VARO!
AVATTAESSA JA SUOJALUKITUS
OHITETTAESSA OLET ALTTIINA
NÄKYMÄTTÖMÄLLE LASERSÄTEILYLLE. ÄLÄ
KATSO SÄTEESEEN.
VARNING!
OSYNLIG LASERSTRÅLNING NÄR DENNA DEL
ÄR ÖPPNAD OCH SPÄRREN ÄR URKOPPLAD.
BETRAKTA EJ STRÅLEN.
CAUTION
Use of controls or adjustments or performance of
procedures other than those specified herein may
result in hazardous radiation exposure.
ATTENTION
L’emploi de commandes, de réglages ou un choix
de procédures différents des spécifications de cette
brochure peut entraîner une exposition à
d’éventuelles radiations pouvant être dangereses.
ACHTUNG
Die Verwendung von Bedienungselementen oder
Einstellungen oder die Durchführung von
Bedienungsvorgängen, die nicht in dieser Anleitung
aufgeführt sind, kann zu einem Kontakt mit
gefährlichen Laserstrahlen führen.
OBSERVERA
Användning av kontroller och justeringar eller
genomförande av procedurer andra än de som
specificeras i denna bok kan resultera i att du
utsätter dig för farlig strålning.
ATTENZIONE
Uso di controlli o regolazioni o procedure non
specificamente descritte può causare l’esposizione
a radiazioni di livello pericoloso.
PRECAUCIÓN
El uso de los controles o los procedimientos de
ajuste o utilización diferentes de los especificados
en este manual pueden causar una exposición
peligrosa a la radiación.
VOORZICHTIG
Gebruik van bedieningsorganen of instellingen, of
uitvoeren van handelingen anders dan staan
beschreven in deze handleiding kunnen leiden tot
blootstelling aan gevaarlijke stralen.
0101MDXE300(M).cv1-4.E 02.5.17, 0:02 PM1
1 To assure the finest performance, please read this
manual carefully. Keep it in a safe place for future
reference.
2 Install this unit in a well ventilated, cool, dry, clean
place away from direct sunlight, heat sources, vibration,
dust, moisture or cold. In a cabinet, allow about 2.5 cm
(1 inch) of free space all around this unit for adequate
ventilation.
3 Locate this unit away from other electrical appliances,
motors, or transformers to avoid humming sounds.
4 Do not expose this unit to sudden temperature changes
from cold to hot, nor locate this unit in an environment
with high humidity (i.e., a room with a humidifier) to
prevent condensation inside this unit, which may cause
an electrical shock, fire, damage to this unit, and/or
personal injury.
5 Avoid installing this unit in a location where foreign
objects may fall onto this unit or where this unit may be
exposed to liquid dripping or splashing. On the top of
this unit, do not place:
Other components, as they may cause damage and/or
discoloration on the surface of this unit.
Burning objects (i.e., candles), as they may cause fire,
damage to this unit, and/or personal injury.
Containers with liquid in them, as they may fall, spilling
the liquid and causing an electrical shock to the user
and/or damage to this unit.
6 Do not cover this unit with a newspaper, tablecloth,
curtain, etc. in order not to obstruct heat radiation. If the
temperature inside this unit rises, it may cause fire,
damage to this unit, and/or personal injury.
7 Do not plug in this unit to a wall outlet until all
connections are complete.
8 Do not operate this unit upside-down. It may overheat,
possibly causing damage.
9 Do not use excessive force on switches, knobs and/or
cords.
10 When disconnecting the power cord from the wall
outlet, grasp the plug; do not pull the cord.
11 Do not clean this unit with chemical solvents; this might
damage the finish. Use a clean, dry cloth.
12 Use only the voltage specified on this unit. Using this
unit with a higher voltage than specified is dangerous
and may cause fire, damage to this unit, and/or personal
injury. YAMAHA will not be held responsible for any
damage resulting from use of this unit with a voltage
other than as specified.
13 To prevent damage by lightning, disconnect the power
cord from the wall outlet during an electrical storm.
14 Do not attempt to modify or fix this unit. Contact
qualified YAMAHA service personnel when any service
is needed. The cabinet should never be opened for any
reason.
15 When not planning to use this unit for long periods of
time (i.e., vacation), disconnect the AC power plug from
the wall outlet.
16 Be sure to read the “Troubleshooting” section on
common operating errors before concluding that this
unit is faulty.
CAUTION: READ THIS BEFORE OPERATING THIS UNIT
17 Before moving this unit, press STANDBY/ON to set the
unit in standby mode, then disconnect the AC power
plug from the wall outlet.
18 VOLTAGE SELECTOR (China and General models
only)
The VOLTAGE SELECTOR on the rear panel of this
unit must be set for your local main voltage BEFORE
plugging into the AC main supply. Voltages are 110/120/
220/240 V AC, 50/60 Hz.
To reduce the risk of fire or electric shock, do not
expose this appliance to rain or moisture.
The unit is not disconnected from the AC power source
as long as it is connected to the wall outlet, even if this
unit itself is turned off. This state is called the standby
mode. In this state, this unit is designed to consume a
very small quantity of power.
SPECIAL INSTRUCTIONS FOR U.K. MODEL
IMPORTANT:
The wires in the mains lead are coloured in accordance
with the following code:
Blue: NEUTRAL
Brown: LIVE
As the colours of the wires in the mains lead of this
apparatus may not correspond with the coloured
markings identifying the terminals in your plug,
proceed as follows: The wire which is coloured BLUE
must be connected to the terminal which is marked
with the letter N or coloured BLACK. The wire which
is coloured BROWN must be connected to the terminal
which is marked with the letter L or coloured RED.
Making sure that neither core is connected to the earth
terminal of the three pin plug.
For U.K. customers
If the socket outlets in the home are not suitable for the
plug supplied with this appliance, it should be cut off and
an appropriate 3 pin plug fitted. For details, refer to the
instructions described above.
Note: The plug severed from the mains lead must be
destroyed, as a plug with bared flexible cord is hazardous
if engaged in a live socket outlet.
CAUTION
Use of controls or adjustments or performance of
procedures other than those specified herein may
result in hazardous radiation exposure.
0102MDXE300(M).Cau.E 02.5.17, 10:53 AM2
1
English
FEATURES
MINI DISC digital audio system
Digital optical input (2)/output
Sampling rate converter
EDIT function
CONTENTS
FEATURES .............................................. 1
SUPPLIED ACCESSORIES ....................... 2
NOTES ABOUT MINIDISCS .................... 2
NAMES OF BUTTONS AND CONTROLS
Front panel ............................................................ 3
Display .................................................................. 3
Remote control ..................................................... 4
GETTING STARTED
Remote control ..................................................... 5
System connections .............................................. 6
Connecting your audio system ............................. 8
PLAYBACK............................................. 9
Skipping tracks ..................................................... 9
Searching .............................................................. 9
Switching the display ......................................... 10
Random play ....................................................... 11
Repeat play ......................................................... 11
A-B repeat .......................................................... 11
Program play ...................................................... 12
RECORDING ........................................ 13
Adjusting recording levels .................................. 14
Track marking ..................................................... 14
Music synchro recording .................................... 15
Setting the recording mode ................................. 15
Monitor out ......................................................... 16
Protecting a recorded MD .................................. 16
EDITING ............................................... 17
Erase ................................................................... 18
Move ................................................................... 19
Combine ............................................................. 19
Divide ................................................................. 20
Undo ................................................................... 20
TOC write ........................................................... 20
FRA check .......................................................... 20
TITLING................................................ 21
ADDITIONAL INFORMATION
MD recorder system notes .................................. 22
Display messages................................................ 23
Troubleshooting .................................................. 24
Specifications...................................................... 25
Synchronized recording/timer recording
by system connection
Digital rec level control
MDLP (Long play and recording)
0103MDXE300(M).1-8.E 02.5.17, 10:53 AM1
2
SUPPLIED ACCESSORIES
Check that the following items are included.
Remote control
Batteries (AA, R6, UM-3)
Optical cable
System control cable
Audio pin cable
NOTES ABOUT MINIDISCS
Care of MDs
Do not expose the MD to direct sunlight or heat sources
such as hot air ducts, nor leave it in a car parked in
direct sunlight as there can be a considerable rise in
temperature inside the car.
Periodically remove dust and debris from the cartridge
surface by wiping it with a dry cloth.
Because the MD itself is housed in a cartridge, you can
handle it normally without being concerned about dirt
or fingerprints. However, malfunctioning may result if
the cartridge itself is dirty or warped.
Do not open the shutter on the MD
cartridge
Trying to force the shutter open will damage the shutter.
TITLE
DELETE
SET
CANCEL ENTER
EDIT
CHAR
NUMBER
A B C D E F G H I J K L
1234
5678
90
+10 +100
A-B S/F
DISPLAY
POWER
SCROLL
M N O P Q R S T U V W X
Y Z
REC/
PAUSE
SYNC
/
SPACE
M-MARK REC MODE
INPUT
RANDOM PROGRAM
REPEAT
0103MDXE300(M).1-8.E 02.5.17, 10:53 AM2
3
English
NAMES OF BUTTONS AND CONTROLS
Front panel
1 STANDBY/ON (P.9)
2 Disc insertion slot (P.9)
3 (P.9)
4 & (P.9)
5 #/* (P.9)
6 REC/PAUSE (P.13)
Display
1 Input indicator (P.13)
2 TOTAL indicator (P.10)
3 DISC/TRACK indicator (P.10)
4 REMAIN indicator (P.10)
5 MANUAL indicator (P.14)
6 REC indicator (P.13)
7 Pause indicator
8 Multi information display
9 Sampling frequency indicator (P.13)
STANDBY/ON
NATURAL SOUND MINIDISC RECORDER MDX-E300
+
INPUT
ANALOG
REC LEVEL
DIGITAL
MIN MAX
REC/PAUSE
123456
7890q
ANALOG
DIGITAL
COAX.
32 44.1 48
kHz
REPEAT
MANUAL
REC
MONO
LP2 LP4
TOC
DISC TRACK
TOTAL
REMAIN
RANDOM
PROGRAM
A-B S F
L
R
dB
60 30 10 6 4 2 1 0 OVER00
––
OPT.12
qwer ty u90
1234567 8
0 REPEAT A-B/S F indicator (P.11)
q PROGRAM indicator (P.12)
w RANDOM indicator (P.11)
e MONO indicator (P.15)
r LP2/LP4 indicator (P.15)
t TOC indicator (P.17)
y Play indicator
u Recording level meter (P.14)
7 Remote control sensor (P.5)
8 Display (P.3)
9 INPUT (P.13)
0 ANALOG REC LEVEL (P.14)
q Jog dial ($ )/DIGITAL REC LEVEL
(P.9/P.14)
0103MDXE300(M).1-8.E 02.5.17, 10:53 AM3
4
Remote control
1 DELETE/CANCEL (P.21)
2 TITLE (P.21)
3 CHAR (P.21)
4 NUMBER (P.21)
5 Numbers [Characters] (P.9/P.21)
6 # (P.9/P.14)
7 ! (P.9/P.21)
8 $ (P.9/P.21)
9 REC/PAUSE (P.13)
0 M-MARK (P.14)
q REC MODE (P.15)
w RANDOM (P.11)
e PROGRAM (P.12)
r POWER (P.9)
t SET/ENTER (P.21)
y EDIT (P.18)
u * (P.9)
i (P.9/P.21)
o (P.9/P.21)
p SYNC (P.15)
a & (P.9)
s INPUT (P.13)
d REPEAT A-B (P.11)
REPEAT S/F (P.11)
f SCROLL (P.10)
g DISPLAY (P.10)
NAMES OF BUTTONS AND CONTROLS
TITLE
DELETE
SET
CANCEL ENTER
EDIT
CHAR
NUMBER
A B C D E F G H I J K L
1234
5678
90
+10 +100
A-B S/F
DISPLAY
POWER
SCROLL
M N O P Q R S T U V W X
Y Z
REC/
PAUSE
SYNC
/
SPACE
M-MARK REC MODE
INPUT
RANDOM PROGRAM
REPEAT
1t
y
u
i
o
p
a
s
d
f
g
2
3
4
5
6
8
9
0
q
w
e
r
7
0103MDXE300(M).1-8.E 02.5.17, 10:53 AM4
5
English
Remote control
Battery installation
1 Remove the battery compartment cover.
2 Insert batteries into the battery compartment.
3 Replace the battery compartment cover.
Battery replacement
If you find that the remote control must be used closer to
the main unit than usual, the batteries are weak. Replace
batteries with new ones.
Notes
Use only AA, R6, UM-3 batteries for replacement.
Be sure the polarities are correct. (See the illustration inside
the battery compartment.)
Remove the batteries if the remote control will not be used for
an extended period of time.
If batteries leak, dispose of them immediately. Avoid touching
the leaked material or letting it come in contact with clothing,
etc. Clean the battery compartment thoroughly before
installing new batteries.
Remote control operation range
Notes
There should be no large obstacles between the remote control
and the main unit.
If the remote control sensor is directly illuminated by strong
lighting (especially an inverter type of fluorescent lamp, etc.),
it might cause the remote control not to work correctly. In this
case, reposition the main unit to avoid direct lighting.
Removing the protection sheet
The remote control is shipped with a protection sheet to
prevent the surface from being scratched during
transportation.
When removing the sheet, first put adhesive tape on an
edge of the remote control so that the tape sticks to the
sheet. Then peel the sheet off with the tape.
Note
Do not scratch the remote control surface when peeling the
sheet off.
GETTING STARTED
STANDBY/ON
NATURAL SOUND MINIDISC RECORDER MDX-E300
+
INPUT
ANALOG
REC LEVEL
DIGITAL
MIN MAX
REC/PAUSE
30°
30°
Remote control
sensor
Within approximately
6 m (20 feet)
2
1
3
TITL
E
D
E
L
E
T
E
S
ET
C
H
A
R
N
U
M
B
E
R
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R S
T
U
V
W
X
Y
Z/
S
P
A
C
E
C
A
N
C
E
L
E
N
T
E
R
E
D
IT
1
2
3
4
5
6
7
8
9
0
+10
+100
T
I
T
L
E
D
E
L
E
T
E
S
E
T
C
H
A
R
N
U
M
B
E
R
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
/
S
P
A
C
E
CANCEL ENTER
E
D
I
T
1
2
3
4
5
6
7
8
9
0
+
1
0
+
1
0
0
0103MDXE300(M).1-8.E 02.5.17, 10:53 AM5
6
System connections
Never plug the AC power cord to the wall outlet until all connections are
completed.
Connections should be made to the correct input/output jacks on the other component.
Also refer to the owners manual supplied with the components you are connecting.
If the placement of this unit causes noise in other equipment, such as a tuner, move them farther apart.
The connection using the SYSTEM CONNECTOR jack allows you to control this unit as well as the connected
components of YAMAHA Piano Craft series. Make system control connections between the Piano Craft series
components using the system control cable.
To reduce the standby power consumption, connect the AC power cord of this unit to a switched AC outlet of your
receiver (Except for U.K. model).
Notes
Before making OPTICAL connections, remove the jack cover(s).
In order to protect the jacks from dust, be sure to attach the jack covers when the optical jacks are not being used.
Connecting CRX-E300
GETTING STARTED
ANALOG DIGITAL
OPTICAL
SYSTEM
CONNECTOR
IN
L
D
OUT
1
IN
2 OUT
R
C
MD
TAPE
IN
OUT
IN
IN
OUT
AUX
D
A
B
LR
C
OUT
6
MIN. /SPEAKER
OUT
DIGITAL
SUBWOOFER
OPTICAL
SPEAKERS
RL
FM ANT
GND AM ANT
75 UNBAL.
SYSTEM CONNECTOR
This unit (MDX-E300)
CD receiver (CRX-E300)
Audio pin
cables
(included)
Optical cable
(included)
System control cable
(included)
To wall outlet
To CRX-E300
Notes
The ANALOG OUT jacks on this unit are marked Ç and the ANALOG IN jacks are marked Î. When connecting this unit to
CRX-E300 whose jacks are marked Å, ı, Ç and Î, connect this units ANALOG OUT jacks to the input jacks marked Ç and connect
this units ANALOG IN jacks to the output jacks marked Î on the rear panel of CRX-E300.
The SYSTEM CONNECTOR jack should be connected to the SYSTEM CONNECTOR jack on CRX-E300.
For digital recording, the DIGITAL OPTICAL 1 IN jack should be connected to the DIGITAL OPTICAL OUT jack on CRX-E300.
0103MDXE300(M).1-8.E 02.5.17, 10:53 AM6
7
English
ANALOG DIGITAL
OPTICAL
SYSTEM
CONNECTOR
IN
L
D
OUT
1
IN
2 OUT
R
C
FM ANT
75 UNBAL.
IN
IN
IN
IN
OUT
OUT
6 MIN./SPEAKER
SPEAKERS
SUBWOOFER
OUT
SYSTEM
CONNECTOR
GND
AM
ANT
TAPE
CD
AUX
MD
R
L
R L
+
A
B
E
C
D
ANALOG DIGITAL
OPTICAL
SYSTEM
CONNECTOR
L
OUT
OUT
R
E
GETTING STARTED
To wall outlet
Notes
The ANALOG OUT jacks on this unit are marked Ç and the ANALOG IN jacks are marked Î. When connecting this unit to RX-E400
whose jacks are marked Å, ı, Ç, Î and , connect this units ANALOG OUT jacks to the input jacks marked Ç and connect this
units ANALOG IN jacks to the output jacks marked Î on the rear panel of RX-E400.
The SYSTEM CONNECTOR jack should be connected to the SYSTEM CONNECTOR jack on CDX-E400.
For digital recording, the DIGITAL OPTICAL 1 IN jack should be connected to the DIGITAL OPTICAL OUT jack on CDX-E400.
Connecting RX-E400 and CDX-E400
CD player (CDX-E400)
This unit (MDX-E300)
Receiver (RX-E400)
To RX-E400
Optical cable
(included)
System control cable
(included)
Audio pin cables
(included)
System control cable
To RX-E400
0103MDXE300(M).1-8.E 02.5.17, 10:53 AM7
8
DIGITAL OUT
OPTICAL
DIGITAL IN DIGITAL OUT
OPTICAL OPTICAL
ANALOG DIGITAL
OPTICAL
SYSTEM
CONNECTOR
IN
L
D
OUT
1
IN
2 OUT
R
C
Connecting your audio system
Digital connections
GETTING STARTED
Notes for digital connections
The DIGITAL OPTICAL IN jacks can be connected to any component with an optical output so you can make direct digital recordings.
The DIGITAL OPTICAL OUT jacks can be connected to any component with an optical input so you can output digital audio from an
MD.
Before making OPTICAL connections, remove the jack cover(s).
In order to protect the jacks from dust, be sure to attach the jack covers when the optical jacks are not being used.
Analog connections
Notes for analog connections
The white plug on the audio pin cables corresponds to the L (left) channel and the red plug corresponds to the R (right) channel. Be sure
to connect L (left) to L and R (right) to R. Also make sure that the plugs are fully inserted and that the connection is firm.
The ANALOG OUT jacks on this unit should be connected to the MD PLAY jacks on your amplifier.
The ANALOG IN jacks on this unit should be connected to the MD REC jacks on your amplifier.
MD/TAPE
ANALOG DIGITAL
OPTICAL
SYSTEM
CONNECTOR
IN
L
D
OUT
1
IN
2 OUT
R
C
This unit (MDX-E300)
Optical cable
Audio pin cables
CD player (etc.) with
optical OUT
Amplifier/Receiver
with optical IN/OUT
Optical cable
Optical cable
This unit (MDX-E300)
Amplifier/Receiver
To AC outlet
To AC outlet
0103MDXE300(M).1-8.E 02.5.17, 10:53 AM8
9
English
English
STANDBY/ON
NATURAL SOUND MINIDISC RECORDER MDX-E300
+
INPUT
ANALOG
REC LEVEL
DIGITAL
MIN MAX
REC/PAUSE
1 Insert an MD.
2 Press #/* (# on the remote control) to start
playback.
3 Adjust the volume using the volume control on the
amplifier (or receiver).
STANDBY/ON
Jog dial
&
1
2
TITLE
DELETE
SET
CANCEL ENTER
EDIT
CHAR
NUMBER
A B C D E F G H I J K L
1234
5678
90
+10 +100
A-B S/F
DISPLAY
POWER
SCROLL
M N O P Q R S T U V W X
Y Z
REC/
PAUSE
SYNC
/
SPACE
M-MARK REC MODE
INPUT
RANDOM PROGRAM
REPEAT
!
2
*
Numbers
&
$›
POWER
To pause
Press #/* (* on the remote control).
Press again to resume playback (or press # on the remote
control).
To stop
Press &.
To eject the MD
Press .
Skipping tracks
To skip to the next track
Turn the jog dial to the right (or press on the remote
control).
To skip to a previous track
Turn the jog dial to the left (or press $ on the remote
control).
To skip to a specific track number
Press the number buttons on the remote control
corresponding to the track you desire.
Example:
To select track 3, press 3.
To select track 13, press +10, then press 3.
To select track 23, press +10 twice, then press 3.
To select track 123, press +100 once, and +10 twice, then
press 3.
Searching
To search forward during play or
pause
Press and hold on the remote control.
To search in reverse during play or
pause
Press and hold ! on the remote control.
Notes
Sound can be heard when searching in play mode to help you
locate the desired position within the track. No sound is heard
when searching in pause mode, but the search is conducted at a
higher speed.
Search may not function correctly when there are several
consecutive tracks consisting of only a few seconds each.
Arrow pointed toward
disc insertion slot
Label facing up
Preparation
Press STANDBY/ON (POWER on the remote control)
to turn this unit on.
Select MD as the input source of the connected
receiver.
PLAYBACK
0104MDXE300(M).9-12.E 02.5.17, 10:54 AM9
10
Switching the display
Press DISPLAY during stop or playback to display other
information, such as the remaining time and track titles.
During stop
Press DISPLAY repeatedly to display the following
information.
1 Number of tracks and total playing time
2 Time remaining on the MD (only for recordable
MDs)
3 Disc title
During playback
Press DISPLAY repeatedly to display the following
information.
1 Current track number and elapsed time
2 Time remaining on the current track
3 Track title
If the track has not been given a name, No Title
is displayed.
To view the entire disc (track) title
If the disc (track) title is too long to fit in the display,
press SCROLL to move the title sequentially across the
display. While the title is being displayed, press
SCROLL to pause the display, and again to continue
presentation of the title. Press and hold SCROLL for
rapid presentation of the title.
A-B S/F
DISPLAY
POWER
SCROLL
REC/
PAUSE
SYNC
M-MARK REC MODE
INPUT
RANDOM PROGRAM
REPEAT
SCROLL
DISPLAY
ANALOG
DIGITAL
OPT.123
COAX.
32 44.1 48
kHz
REPEAT
MONO
REC
MANUAL
TOC
DISC TRACK
TOTAL
REMAIN
RANDOM
PROGRAM
A-B S F
L
R
dB
60 30 10 6 4 2 1 0 OVER00
––
ANALOG
DIGITAL
OPT.123
COAX.
32 44.1 48
kHz
REPEAT
MONO
REC
MANUAL
TOC
DISC TRACK
TOTAL
REMAIN
RANDOM
PROGRAM
A-B S F
L
R
dB
60 30 10 6 4 2 1 0 OVER00
––
ANALOG
DIGITAL
OPT.123
COAX.
32 44.1 48
kHz
REPEAT
MONO
REC
MANUAL
TOC
DISC TRACK
TOTAL
REMAIN
RANDOM
PROGRAM
A-B S F
L
R
dB
60 30 10 6 4 2 1 0 OVER00
––
ANALOG
DIGITAL
OPT.123
COAX.
32 44.1 48
kHz
REPEAT
MONO
REC
MANUAL
TOC
DISC TRACK
TOTAL
REMAIN
RANDOM
PROGRAM
A-B S F
L
R
dB
60 30 10 6 4 2 1 0 OVER00
––
ANALOG
DIGITAL
OPT.123
COAX.
32 44.1 48
kHz
REPEAT
MONO
REC
MANUAL
TOC
DISC TRACK
TOTAL
REMAIN
RANDOM
PROGRAM
A-B S F
L
R
dB
60 30 10 6 4 2 1 0 OVER00
––
ANALOG
DIGITAL
OPT.123
COAX.
32 44.1 48
kHz
REPEAT
MONO
REC
MANUAL
TOC
DISC TRACK
TOTAL
REMAIN
RANDOM
PROGRAM
A-B S F
L
R
dB
60 30 10 6 4 2 1 0 OVER00
––
Total tracks
Total playing time
REMAIN indicator Time remaining on the MD
Total tracks
REMAIN indicator
Track number
Elapsed time
PLAYBACK
0104MDXE300(M).9-12.E 02.5.17, 10:54 AM10
11
English
English
Random play
You can have the unit play all the tracks on a disc in
random order.
To start random playback
Press RANDOM.
The RANDOM indicator lights up and _ _ _ - - : - -
appears in the display while the unit selects a track.
Playback starts automatically.
To cancel
Press RANDOM again to turn off the RANDOM
indicator or press &.
Note
Pressing during random play skips to another track at
random. Pressing $ returns to the beginning of the current
track (you cannot return to previously played tracks).
Repeat play
You can have the unit repeat a single track, a full disc, or
just part of a track.
Press REPEAT S/F repeatedly to light the REPEAT S or
REPEAT F indicators.
To repeat the single track, light the REPEAT S indicators.
To repeat the full disc, light the REPEAT F indicators.
To cancel
Press REPEAT S/F repeatedly to turn off the REPEAT S
or REPEAT F indicators.
Notes on full disc repeat
In program play mode, the entire program is played repeatedly.
In random play mode, the unit reshuffles the tracks and plays
them again after each track plays once.
A-B repeat
This function lets you repeat a specific part of a track.
Its a convenient way to study a language, or to learn the
lyrics to your favorite song (etc.).
1 Press REPEAT A-B during playback to specify the
beginning (A point) of the part you want to repeat.
The REPEAT A indicators light up.
2 Press REPEAT A-B again to specify the end (B
point) of the part you want to repeat.
The REPEAT A-B indicators light up and the part
you specified starts to repeat.
To cancel
Press & or REPEAT A-B.
A-B S/F
DISPLAY
POWER
SCROLL
REC/
PAUSE
SYNC
M-MARK REC MODE
INPUT
RANDOM PROGRAM
REPEAT
REPEAT S/F
REPEAT A-B
RANDOM
A-B S/F
DISPLAY
POWER
SCROLL
REC/
PAUSE
SYNC
M-MARK REC MODE
INPUT
RANDOM PROGRAM
REPEAT
COAX
.
32 44.1 48
kHz
REPEAT
MONO
REC
MANUAL
TOC
RANDOM
PROGRAM
A-B S F
L
R
dB
60 30 10 6 4 2 1 0 OVER00
––
COAX
.
32 44.1 48
kHz
REPEAT
MONO
REC
MANUAL
TOC
RANDOM
PROGRAM
A-B S F
L
R
dB
60 30 10 6 4 2 1 0 OVER00
––
COAX.
32 44.1 48
kHz
REPEAT
MONO
REC
MANUAL
TOC
RANDOM
PROGRAM
A-B S F
L
R
dB
60 30 10 6 4 2 1 0 OVER00
––
COAX
.
32 44.1 48
kHz
REPEAT
MONO
REC
MANUAL
TOC
RANDOM
PROGRAM
A-B S F
L
R
dB
60 30 10 6 4 2 1 0 OVER00
––
PLAYBACK
0104MDXE300(M).9-12.E 02.5.17, 10:54 AM11
12
Program play
This function lets you enjoy listening to your favorite
tracks in any order you desire.
1 Press & to stop playback.
2 Press PROGRAM to light up the PROGRAM
indicator.
3 Program the desired track by pressing the
corresponding number buttons.
Example:
To select track 3, press 3.
To select track 13, press +10, then press 3.
To select track 23, press +10 twice, then press 3.
To select track 123, press +100 once, and +10 twice,
then press 3.
Repeat this operation to program up to 30 steps.
4 Press PROGRAM to confirm the program.
5 Press # to start program playback.
To check the programmed data
1 Stop or pause program playback.
2 Press $ or to skip through the step
information (or use the jog dial on the front panel).
To change a step
1 Stop program playback.
2 Press PROGRAM.
3 Press $ or to skip through the step
information (or use the jog dial on the front panel).
4 Use the number buttons to program a new track
number for that step. The original track is cleared
from memory and the new track is programmed.
To delete a specific step
1 Stop program playback.
2 Press PROGRAM.
3 Press $ or to skip through the step
information (or use the jog dial on the front panel).
4 Press DELETE to delete the step. The higher steps
are renumbered automatically.
To cancel
During the stop mode, press & to turn off the PROGRAM
indicator.
Notes
If the total time exceeds 100 minutes, Over is displayed
instead of the total time.
$ or can be used during playback to skip between
programmed tracks.
5
Current programmed
track number
Total playing time
2,4
3
DELETE/
CANCEL
!
$
1
TITLE
DELETE
SET
CANCEL ENTER
EDIT
CHAR
NUMBER
A B C D E F G H I J K L
1234
5678
90
+10 +100
A-B S/F
DISPLAY
POWER
SCROLL
M N O P Q R S T U V W X
Y Z
REC/
PAUSE
SYNC
/
SPACE
M-MARK REC MODE
INPUT
RANDOM PROGRAM
REPEAT
ANALOG
DIGITAL
OPT.123
COAX.
32 44.1 48
kHz
REPEAT
MONO
REC
MANUAL
TOC
DISC TRACK
TOTAL
REMAIN
RANDOM
PROGRAM
A-B S F
L
R
dB
60 30 10 6 4 2 1 0 OVER00
––
PLAYBACK
0104MDXE300(M).9-12.E 02.5.17, 10:54 AM12
13
English
English
TITLE
DELETE
SET
CANCEL ENTER
EDIT
CHAR
NUMBER
A B C D E F G H I J K L
1234
5678
90
+10 +100
A-B S/F
DISPLAY
POWER
SCROLL
M N O P Q R S T U V W X
Y Z
REC/
PAUSE
SYNC
/
SPACE
M-MARK REC MODE
INPUT
RANDOM PROGRAM
REPEAT
STANDBY/ON
NATURAL SOUND MINIDISC RECORDER MDX-E300
+
INPUT
ANALOG
REC LEVEL
DIGITAL
MIN MAX
REC/PAUSE
STANDBY/ON
&
1
8
8
*
DELETE/
CANCEL
&
POWER
Note
Please check the copyright laws in your country to
record from records, compact discs, radio, etc.
Recording of copyright material may infringe
copyright laws.
This unit allows you to make recordings from a wide
variety of program sources (both analog and digital).
When recording an analog source (such as an FM
broadcast or cassette) this unit converts the analog signals
to a 44.1 kHz digital signal before recording them onto
the MD.
When recording a digital source, this unit converts the
digital signals to 44.1 kHz for recording onto the MD.
However, if you are recording a 44.1 kHz source signal
(such as a CD) there is no conversion. This unit can
record 32, 44.1 and 48 kHz digital signals.
Preparation
Press STANDBY/ON (POWER on the remote control)
to turn this unit on.
6
277
6
M-MARK
SET/ENTER
2
1 Insert an MD.
2 Press INPUT repeatedly to select the input you want
to record.
For Select
ANALOG IN Î ANALOG
DIGITAL OPTICAL 1 IN DIGITAL OPT. 1
DIGITAL OPTICAL 2 IN DIGITAL OPT. 2
* Appears when digital signal is input.
3 If desired, press REC MODE to select the recording
mode (see Setting the recording mode on page 15).
4 Locate the point where you want to start recording.
When recording on a blank MD
Skip this step.
To start recording from the end of a previous
recording
Press & to set this unit to stop mode.
To record over a previous recording
Turn the jog dial (or press $ or on the remote
control) to select a track (recording starts from the
beginning of the deleted track).
5 Start playing the source to be recorded.
If you do not need to adjust the recording level,
this step is not necessary.
6 Press REC/PAUSE to set this unit to record pause
mode.
The REC * indicators light up.
REC Standby and the amount of time available
for recording flash alternately in the display.
If you selected a track number (in step 4) to
record over a previous recording
•“OverWrite OK? appears in the display.
To confirm, press SET/ENTER. This operation will
erase the selected track number (or point) and all
subsequent material.
To cancel, press DELETE/CANCEL (or &).
Arrow pointed toward
disc insertion slot
Label facing up
ANALOG
DIGITAL
OPT.123
COAX.
32 44.1 48
kHz
REPEAT
MONO
REC
MANUAL
TOC
DISC TRACK
TOTAL
REMAIN
RANDOM
PROGRAM
A-B S F
L
R
dB
60 30 10 6 4 2 1 0 OVER00
––
Input indicator
(Source) sampling frequency indicators*
RECORDING
3
0105MDXE300(M).13-16.E 02.5.17, 10:54 AM13
14
7 Adjust the recording levels. (See Adjusting
recording levels on this page.)
Before proceeding to the next step, be sure to reset
the source to be recorded to the beginning.
8 Press #/* (# on the remote control) to start
recording.
The TOC indicator lights up.
When the TOC indicator is lit, this means that the
TOC information has not yet been written to the
disc. After recording is complete, the TOC data is
automatically written to the disc.
9 Start playing the source to be recorded.
Synchronized start is possible if you make system
control connections to CRX-E300, CDX-E400 or
KX-E300. Press ^ on CRX-E300, CDX-E400
or # on KX-E300 to start playing the source after
step 7. The recording begins automatically. To use
timer recording, please refer to the instructions
supplied with CRX-E300 or CRX-E400.
To pause
Press REC/PAUSE.
Press #/* (# on the remote) to resume recording.
To stop
Press &.
To eject the MD
Press .
If the power cord is disconnected while making a
recording, the TOC data cannot be correctly written to
the disc and the recorded data will be erased.
TOC writing may be impossible (or track number
marking may not perform as expected) when recording
a damaged CD or a broadcast source with interference.
Adjusting recording levels
Setting the digital recording level
The digital recording level is set by default to 0 dB, the
level of the input source. Normally, it is not necessary to
adjust this level. However, because of the variance in
levels between different digital formats and sources, it is
possible to adjust the recording level of the digital signal.
The digital level can be adjusted up to +12 dB and down
to a minimum (MIN) level. Adjust DIGITAL REC
LEVEL so that the highest peak causes the 0 dB level
indicators to flicker. Do not cause the OVER indicator to
light. Once recording is stopped, the digital recording
level returns to the default level of 0 dB.
Setting the analog recording level
For best results, play the loudest passage of the source to
be recorded and watch the recording level meter in the
display.
Adjust ANALOG REC LEVEL so that the highest peak
causes the 0 dB level indicators to flicker. Do not cause
the OVER indicator to light as it may produce distortion
in the audio signal.
Note
To adjust the recording level of a source connected with the
system control cable, remove the MD before pressing ^ (or
#) on the source component. If you press the button with an
MD in this unit, the recording begins automatically.
Track marking
When making a recording, you can choose either
automatic or manual marking. This feature operates
somewhat differently for analog and digital signals. See
below for details.
Press M-MARK repeatedly to select automatic
(MANUAL indicator is not lit) or manual (MANUAL
indicator lit) marking.
When recording analog signals
Auto : Track numbers are written in synchronization with
the input level of the signal being recorded. During
recording, if no sound is detected for more than 1.5
seconds, the recorder interprets this to be a gap between
two tracks. When the source signal is detected again, a
track number is automatically written.
Manual : One track number is written automatically
when you start recording, but none are written during
recording. To mark a track number, press M-MARK at the
desired position while recording.
Note
When using manual marking, the marks must be set at least 4
seconds apart.
When recording digital signals
Track numbers are written in the same positions as the
original source (CD, etc.) with either automatic or manual
marking.
To add additional track numbers, set M-MARK to
MANUAL and press M-MARK at the desired position
while recording.
Notes
When recording is paused, the portion recorded up to the pause
is counted as an individual track. When recording is resumed,
a new track number is created.
During synchronized recording, manual track marking is not
possible.
L
R
dB
60 30 10 6 4 2 1 0 OVER00
––
Should not light
RECORDING
0105MDXE300(M).13-16.E 02.5.17, 10:54 AM14
15
English
English
Music synchro recording
The synchronized recording function lets you set this unit
to start recording automatically when a sound signal is
input.
1 Load the sound source into the source component.
If necessary, program, or select the track you want
to start recording from before proceeding to the
next step. (Refer to the operation manual supplied
with the source component for instructions
regarding its use.)
2 Press INPUT repeatedly to select the input connected
to the sound source you want to record.
3 Press SYNC to set this unit to record pause mode.
The REC * indicators light up.
Synchro REC and the amount of time available
for recording flash alternately in the display.
During synchronized recording, analog input
sources are recorded at the current ANALOG
REC LEVEL setting, digital sources are recorded
at the 0 dB level.
The MD starts recording automatically when a
sound signal is input. When the sound signal
stops, the unit switches back to record pause mode
and Synchro REC blinks in the display. The
next time a sound signal is detected, recording
starts again. In this manner, the presence of a
sound signal automatically switches the unit
between record and record pause modes.
4 Start playing the sound source.
To cancel the synchronized recording
mode
Press &.
Note
When the signals at the beginning of a track are lower than the
level required to start synchronized recording, they are not
recorded. Should this occur, perform manual recording.
SYNC
INPUT
REC MODE
&
Setting the recording
mode
This unit incorporates various recording modes. Choose
the one that suits your needs.
Press REC MODE repeatedly until the indicator for the
desired recording mode lights up.
Example: When using an 80 minute MD
MONO (monaural)
This mode provides 160 minutes monaural recording.
LP2
This mode provides 160 minutes stereo recording.
LP4
This mode provides 320 minutes stereo recording.
When all of the above indicators are turned off, this unit
enters normal stereo recording mode.
Notes
MDLPs (= discs recorded in LP mode) cannot be played back
nor edited on non MDLP players. If you play MDLPs (=discs
recorded in LP mode) on a non-MDLP player, LP: will
appear at the top of the title and no sound will be reproduced.
Normal stereo recording provides the best sound quality.
The recording mode cannot be changed during recording.
A-B S/F
DISPLAY
POWER
SCROLL
REC/
PAUSE
SYNC
M-MARK REC MODE
INPUT
RANDOM PROGRAM
REPEAT
A-B S/F
DISPLAY
POWER
SCROLL
REC/
PAUSE
SYNC
M-MARK REC MODE
INPUT
RANDOM PROGRAM
REPEAT
RECORDING
0105MDXE300(M).13-16.E 02.5.17, 10:54 AM15
16
Monitor out
When a disc is not loaded, you can use the monitor out
function to monitor the sound of the input source. The
monitor out function can also be used to set recording
levels without loading a disc.
1 Press to remove the disc.
2 Press INPUT repeatedly to select the input connected
to the sound source you want to monitor.
3 Press REC/PAUSE.
•“Monitor Out appears in the display.
Sound from the selected input will be output from
this units analog and digital output terminals.
4 Start playing the sound source.
The sound is output from the MD recorders
analog and digital output terminals.
To cancel
Press &.
Notes
This function is useful to monitor the sound of an external
digital component connected to the DIGITAL OPTICAL 2 IN
jack.
The digital volume can be adjusted when using the monitor out
function. However, please note that the digital volume setting
is restored to the default (0 dB) the next time a recording is
made.
STANDBY/ON
NATURAL SOUND MINIDISC RECORDER MDX-E300
+
INPUT
ANALOG
REC LEVEL
DIGITAL
MIN MAX
REC/PAUSE
23
&
1
Protecting a recorded MD
To protect a recorded MD, slide the tab on the side of
the MD to open the slot.
In this position, the MD cannot be used for recording,
editing, or titling. To record, edit, or title the MD, slide
the tab to close the slot.
If the MD is protected against erasure, Protected
appears in the display.
Tab
Slide the tab to
open the slot.
RECORDING
0105MDXE300(M).13-16.E 02.5.17, 10:54 AM16
17
English
English
TITLE
DELETE
SET
CANCEL ENTER
EDIT
CHAR
NUMBER
A B C D E F G H I J K L
1234
5678
90
+10 +100
A-B S/F
DISPLAY
POWER
SCROLL
M N O P Q R S T U V W X
Y Z
REC/
PAUSE
SYNC
/
SPACE
M-MARK REC MODE
INPUT
RANDOM PROGRAM
REPEAT
&
SET/ENTER
EDITING
One of the main advantages of MD is its editing
capabilities. You can remove the commercials from a
radio broadcast, reorder songs into the order you want,
remove songs, combine songs, and even remove part of a
song.
This unit offers the following editing operations.
Erase
Lets you erase a track, the entire disc, or part of a track.
You can also erase the title of a disc, or the titles of tracks
on a disc.
Move
Lets you move a track to a different track number.
Combine
Lets you combine two adjacent tracks.
Divide
Lets you split a single track into two different tracks.
FRA check
Lets you recover disc space that may have been lost after
multiple edit operations.
TOC write
Lets you write TOC information to the disc so that
changes are saved.
Undo
Lets you undo the previous edit operation if you make a
mistake.
Notes on editing
To cancel an edit
Press &.
Before editing
Make sure that the MD is not protected against erasure. If
the MD is protected, you cannot edit the MD. Slide the
tab to close the slot on the side of the MD.
After editing
Press in order to update the TOC information and
pull the MD out.
The TOC indicator lights to show that the TOC
information has not yet been written to the disc. Undo is
possible only when the TOC indicator is lit.
EDIT
$
!
0106MDXE300(M).17-20.E 02.5.17, 10:54 AM17
18
Erase
EDITING
Erase
The ability to erase sound without having to re-record is a
convenient function of MD. You can erase the entire disc,
a single track, or just part of a track.
Disc erase
This operation lets you erase all audio and title (character)
data to create a blank MD. Please note that once erased,
this data can be recovered using the UNDO function.
1 Press & to set this unit to stop mode.
2 Press EDIT repeatedly to display Disc Erase?, then
press SET/ENTER.
•“DiscEraseOK? appears in the display.
3 Press SET/ENTER again.
When all audio, name and title data has been
erased Complete appears momentarily.
Track erase
This operation lets you erase a single track as well as
corresponding title data. After you erase the track, the
total number of tracks decreases by one and all tracks
following that track are renumbered.
Example: Erasing track 3
1 Use $ or to select the track you want to erase.
2 Press EDIT repeatedly to display Erase ?, then
press SET/ENTER.
•“(track number) Erase OK? appears in the
display.
3 Press SET/ENTER again.
The track is erased and Complete appears
momentarily.
If you plan to erase two or more tracks
To avoid confusion you should always erase from higher
track numbers to lower track numbers. This prevents
accidental renumbering of tracks you plan to erase.
Before
erasing
After
erasing
Part erase
This operation lets you erase part of a track.
1 Play the track containing the part you want to erase.
2 Use ! or to locate the beginning of the part
you want to erase (point A), then press * to pause at
that point.
3 Press EDIT repeatedly to display AB Erase?, then
press SET/ENTER.
Point A (from step 2) is registered and Erase
A_ appears in the display.
4 Use # and to locate the end of the part you want
to erase (point B).
5 Press SET/ENTER to register point B.
•“Check appears, then the part you specified plays
repeatedly and Erase AB? appears in the
display.
To adjust points A and B
Press EDIT repeatedly to display A point and B point
alternately. Adjust the selected point by using $ or
in the direction you want to move the point.
Each point can be adjusted up to 2 seconds in either
direction.
6 Press SET/ENTER again.
The part is erased and Complete appears
momentarily.
Notes
After part erase, a new track number is automatically assigned
to the section starting after point B.
Point B cannot be positioned before point A.
Before
erasing
After
erasing
12
AB DEC
3456
12
AB EFD
3456
1
ACB
23
12
A1 A2 CB
34
0106MDXE300(M).17-20.E 02.5.17, 10:54 AM18
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Yamaha MDX-E300 Manuale utente

Categoria
Lettori minidisc
Tipo
Manuale utente