ELEKTRA Professional espresso coffee machines Manuale utente

Categoria
Macchine da caffè
Tipo
Manuale utente
Macchine da caffè espresso professionali
I MANUALE DELL’UTENTE
GB USER MANUAL
D ANWENDERHANDBUCH
F MANUEL DE L’USAGER
E MANUAL DEL USUARIO
ITALIAN ESPRESSO COFFEE MACHINES
ELEKTRA SRL
VIA A. VOLTA,18 - 31030 DOSSON DI CASIER (TREVISO) ITALY
TEL. (+39) 0422 490405 R.A. - FAX (+39) 0422 490620
E-mail: [email protected] - Website: www.elektrasrl.com
I MANUALE DELL’UTENTE GB USER MANUAL D ANWENDERHANDBUCH
F MANUEL DE L’USAGER E MANUAL DEL USUARIO
A.D.: Holbein & Partners - COD. 03662035 - Edition: April 2009
I
Professional espresso coffee machines
GB
Professionelle Espressomaschinen
D
Machines à café expresso professionnelles
F
Máquinas Profesionales para café espresso
E
3
ITALIAN ESPRESSO COFFEE MACHINES
gb
48
gb
49
gb
gb
50
COFFEE DISPENSING (K-Kwts-S-M-C-B)
DISPENSING OF HOT WATER AND STEAM (K-Kwts-S-M-C-B)
ELIMINATION OF CALCIUM AND MAGNESIUM SALTS FROM THE WATER (K-S-M-C-B)
ELIMINATION OF CALCIUM AND MAGNESIUM SALTS FROM THE WATER (Kwts)
AUTOMATIC REGENERATION OF THE WATER SOFTENER RESINS (Kwts)
ELIMINATION OF CHLORINE AND ORGANIC COMPOUNDS FROM THE WATER (Kwts)
CONTROL OF WATER LEVEL IN THE BOILER (K-Kwts-S-M-C-B)
CONTROL OF WATER TEMPERATURE IN THE BOILER (K-Kwts-S-M-C-B)
STABILIZING THE BREWING TEMPERATURE (K-Kwts-S-M-C-B)
MEASURING THE BREWING PRESSURE (K-S-M-C-B)
MEASURING THE BREWING PRESSURE (Kwts)
MEASURING THE WATER SUPPLY PRESSURE (Kwts)
PROTECTING THE HEATING ELEMENTS (K-Kwts-S-M-C-B)
PROTECTING FROM OVERHEATING (K-Kwts-S-M-C-B)
UPPER CUP TRAY (S-M-C-B)
UPPER CUP HEATER TRAY (K-Kwts)
DRIP TRAY (K-Kwts)
USER ALERTS (S-M-C-B)
USER ALERTS (K-Kwts)
BASIC PROGRAMMING (K-Kwts-S-M-C-B)
SPECIAL PROGRAMMING (K-Kwts)
ADJUSTING THE FEET (K-Kwts)
WATER CONNECTIONS (K-S-M-C-B)
WATER CONNECTIONS (Kwts)
WATER SOFTENER CONNECTION (K-S-M-C-B)
WATER SOFTENER CONNECTION (Kwts)
CONNECTION WITHOUT WATER SOFTENER (Kwts)
DRAIN CONNECTION (K-Kwts-S-M-C-B)
ELECTRICAL CONNECTIONS (K-Kwts-S-M-C-B)
FILLING THE HYDRAULIC CIRCUITS (K-S-M-C-B)
FILLING THE HYDRAULIC CIRCUITS (Kwts)
FLUSHING THE MACHINE (USA NSF requirements) (K-Kwts-S-M-C-B)
CONTENTS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
A INTRODUCTION
C DESCRIPTION OF THE APPLIANCE
B GENERAL RECOMMENDATIONS AND SAFETY REGULATIONS
D UNPACKING
INSTALLATIONE
1
2
3
4
5
6
7
8
9
10
11
56
56
56
56
56
56
56
57
57
57
57
57
57
57
57
58
58
58
58
59
59
53
56
54
60
61
61
61
61
62
62
62
63
63
64
64
65
gb
51
SELECTION OF LANGUAGE (K-Kwts)
SETTING OF DATE AND TIME (K-Kwts-S-M-C-B)
STORING OF MEASURED WATER SUPPLY HARDNESS (Kwts)
STORING OF WATER SOFTENER TYPE (Kwts)
ADJUSTING THE BREWING TEMPERATURE (K-Kwts-S-M-C-B)
ADJUSTING THE BREWING PRESSURE (K-Kwts-S-M-C-B)
ADJUSTING THE SALINITY OF THE BREWING WATER (Kwts)
PROGRAMMING OF COFFEE DOSES (K-Kwts-S-M-C-B)
PROGRAMMING OF NIGHT CYCLE (K-Kwts-S-M-C-B)
SWITCHING ON (K-Kwts-S-M-C-B)
USE OF THE WORKING AREAS (M-B)
USE OF THE WORKING AREAS (S-C)
USE OF THE WORKING AREAS (K-Kwts)
COFFEE DISPENSING WITH MANUAL DOSING (K-Kwts-S-M-C-B)
COFFEE DISPENSING WITH AUTOMATIC DOSING (K-Kwts-S-M-C-B)
COFFEE DISPENSING WITH AUTOMATIC DOSING BUT WITH
POSSIBILITY OF STOPPING IT MANUALLY (S-M-C-B)
WARMING THE CUPS (S-M-C-B)
WARMING THE CUPS (K-Kwts)
MAKING THE COFFEE (K-Kwts-S-M-C-B)
MAKING CAPPUCCINO, MILK AND OTHER HOT DRINKS (K-Kwts-S-M-C-B)
MAKING TEA – CAMOMILE TEA - ETC (K-Kwts-S-M-C-B)
USING BASIC PROGRAMMING (S-M-C-B)
USING BASIC PROGRAMMING (K-Kwts)
DAILY CLEANING OF THE GROUPS AND FILTERHOLDERS (K-Kwts-S-M-C-B)
DAILY CLEANING OF STEAM WANDS (K-Kwts-S-M-C-B)
WEEKLY CLEANING OF THE GROUPS (K-Kwts-S-M-C-B)
WEEKLY CLEANING OF THE FILTERS AND FILTERHOLDERS (K-Kwts-S-M-C-B)
WEEKLY CLEANING OF LOWER DRIP TRAY (K-Kwts-S-M-C-B)
WEEKLY CLEANING OF BODY (K-Kwts-S-M-C-B)
CLEANING THE WATER SOFTENER (K-S-M-C-B)
REGENERATING THE WATER SOFTENER RESINS (K-S-M-C-B)
REGENERATING THE WATER SOFTENER RESINS (Kwts)
CHANGING THE ACTIVATED CARBON CARTRIDGE (Kwts)
RINSING THE WATER TREATMENT CIRCUIT (Kwts)
F
G
ADJUSTMENTS
USE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
4
5
6
7
8
9
10
11
H
MAINTENANCE AND CLEANING
1
2
3
4
5
6
7
8
9
67
67
67
67
67
67
68
88
68
67
80
80
80
80
80
80
80
80
81
82
82
82
69
69
69
69
70
70
70
70
71
71
71
71
72
72
79
gb
52
DISPLAY OF FUNDAMENTAL PARAMETERS (S-M-C-B)
DISPLAY OF FUNDAMENTAL PARAMETERS (K)
DISPLAY OF FUNDAMENTAL PARAMETERS (Kwts)
DISPLAY AND RESET OF COFFEE PRODUCTION (K-Kwts)
DISPLAY AND RESET OF WATER CONSUMPTION (K-Kwts)
WARNING: BUFFER BATTERY ABOUT TO GO FLAT (K-Kwts-S-M-C-B)
STEAM DOES NOT COME OUT OF THE WAND WHEN THE
MACHINE IS HOT (K-Kwts-S-M-C-B)
WARNING: WATER LEVEL CONTROL SYSTEM FAULT (K-Kwts-S-M-C-B)
WATER COMES OUT OF THE STEAM WAND (K-Kwts-S-M-C-B)
FLASHING OF THE PUSHBUTTON LED DURING DISPENSING (S-M-C-B)
WARNING OF NOT SATISFACTORY BREWING AND FLASHING
OF THE DISPENSING PUSHBUTTON LED (K-Kwts)
WATER DOES NOT COME OUT OF THE DISPENSING GROUP
WHEN THE MANUAL BUTTON IS USED (K-Kwts-S-M-C-B)
ONE DISPENSING GROUP STARTS UP ON ITS OWN (M-B)
WARNING: INADEQUATE WATER SUPPLY PRESSURE (Kwts)
WARNING: NO WATER IN THE BOILER (K-Kwts-S-M-C-B)
WARNING: BREWING TEMPERATURE CONTROL FAULT (K-Kwts-S-M-C-B)
ONE DISPENSING GROUP DOES NOT HEAT SUFFICIENTLY (K-Kwts-S-M-C-B)
THE GAUGE SHOWS A BOILER PRESSURE NOT
BETWEEN 0.6 AND 1.6 BAR (S-M-C-B)
THE GAUGE SHOWS A BREWING PRESSURE NOT
BETWEEN 8 AND 9 BAR (S-M-C-B)
WARNING: WATER SOFTENING SYSTEM FAULT (Kwts)
NO SALT LOADING (Kwts)
THE WATER SOFTENER AND ACTIVATED CARBON CARTRIDGE CAPS
DO NOT OPEN (Kwts)
THE DRIP TRAY IS FULL AND OVERFLOWING WITH WATER (K-Kwts-S-M-C-B)
EUROPEAN TYPE APPROVALS (K-Kwts-S-M-C-B)
AMERICAN TYPE APPROVALS (S-M)
I DATA MANAGEMENT
J TROUBLESHOOTING
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
1
2
K
DISPOSAL OF THE APPLIANCE
1
2
3
4
5
L
TYPE APPROVALS
M
TEST DOCUMENTATION
N
GUARANTEE
83
83
83
83
83
83
90
84
84
84
84
85
85
85
85
86
86
86
86
87
87
87
87
88
88
89
91
91
91
218
219
gb
53
This manual applies to the entire range of professional coffee machines manufactured
by ELEKTRA.
Each topic has been specifi cally treated in a separate paragraph for each model belonging
to the range, indicating the title of the paragraph itself and the models to which it refers,
using the letters shown below:
- K = K model
- Kwts = Kwts model
- S = SIXTIES model (Compact)
- M = MODERN and GOLD models (Maxi and Extramaxi)
- C = CLASSIC model (Barlume)
- B = BELLE EPOQUE model (Vertical 2-3 units)
The SIXTIES model Deliziosa is not included; see the user’s manual October 2007 edition
for this model.
The manual contains all the instructions required for the installer,
the operator (barman) and the manager or owner of the bar.
It also contains some useful recommendations for guiding the service technician
in the event of malfunctioning.
U.S.A. - ATTENTION:
These instructions include some particular specifi cations for the US and Canadian
markets.
INTRODUCTIONA
gb
54
GENERAL RECOMMENDATIONS AND
SAFETY REGULATIONS
B
This booklet is an essential and integral part of the product and must be given to the user.
It contains basic safety instructions that must be followed for the installation, operation and
maintenance of the appliance.
Save these instructions.
After having unpacked the appliance, make sure it is intact.
If in doubt, do not use the appliance and contact a qualifi ed engineer.
The packing elements (plastic bags, polystyrene foam, nails, etc.) should not be left within
reach of children since they are potential sources of danger.
Before connecting the appliance, check that the mains electricity supply corresponds to the
data given on the rating plate.
The rating plate is located under the drip tray (K-Kwts-S-M-C) or inside the upper cup tray (B).
The appliance should be installed by a qualifi ed engineer according to the manufacturer’s
instructions and in compliance with current safety regulations.
Incorrect installation could cause injury to persons or animals and damage to property, for
which the manufacturer cannot be held liable.
This appliance is only electrically safe when it has been connected to an effi cient
grounding system in compliance with current safety regulations.
Make sure that this fundamental safety requirement has been observed and if in doubt
request a thorough check of the system by a qualifi ed electrician.
The manufacturer cannot be held liable for any damage that may be caused by failure to
ground the appliance.
Check that the current carrying capacity of the system is adequate for the maximum rated
output of the appliance (as indicated on the rating plate).
If in doubt, apply to a qualifi ed technician. He should also make sure that the section of the
cables is adequate for the power absorbed by the appliance.
Do not use adapters, multiple current taps or extension cables.
If it is absolutely necessary, only use plugs, simple or multiple adapters and extensions that
comply with current safety regulations. Make sure, however, that the limit of current carrying
capacity does not exceed that indicated on the simple adapter and extensions or the maxi-
mum power value indicated on the multiple adapter.
This appliance should only be used for the purpose for which it was designed.
Any other use is to be considered as unsuitable and therefore dangerous.
The manufacturer cannot be held liable for any damage or injury caused by improper, wrong
or unreasonable use.
1
2
3
4
gb
55
When using electrical appliances, basic safety precautions should always be followed:
- the appliance should be used in environments where the temperature does not fall below
5 °C or rise above 40 °C;
- the appliance has a water circuit containing water, which must not be allowed to freeze
otherwise the appliance could be damaged;
- the appliance should not be cleaned using water jets or installed in a place where water
jets could be used for cleaning;
- the appliance should be installed on the level – it must not slope;
- do not touch the appliance when hands or feet are wet or damp;
- do not operate the appliance barefoot;
- do not use extension cables in bathrooms or shower-rooms;
- do not tug the power supply cable to disconnect the appliance from the mains supply;
- do not expose the appliance to the elements (rain, sun, etc.);
- do not allow children or incompetent persons to use the appliance.
Disconnect the appliance from the mains electricity supply before carrying out any
maintenance, by pulling out the plug or by switching off at the mains switch.
To clean the appliance, follow the instructions in this booklet.
In the event of failure or malfunctioning of the appliance, switch it off and under no
circumstances try to repair it yourself.
Always request service by a qualifi ed technician.
Any repair, electrical or mechanical adjustment should only be carried out at the factory
or by an authorized service center using only original spare parts.
Failure to comply with these instructions could jeopardize the safety of the appliance.
The appliance should be connected to the electricity supply through a multipolar linked
switch having a contact separation of at least 3 mm in all poles, in compliance with current
safety regulations.
Unwind the whole power supply cable to prevent dangerous overheating.
Do not obstruct the intake and outlet grilles. In particular do not cover the upper cup tray
with a cloth or such like.
The supply cable of this appliance should not be replaced by the user.
Should the cable be damaged, switch off the appliance and apply solely to a qualifi ed
electrician for replacement.
Should the machine be used no longer, it must be made inoperative by cutting the supply
cable after having disconnected it from the electrical power supply.
Make sure that all those parts which could be possible sources of danger are made harmless.
6
7
8
9
10
11
12
5
gb
56
DESCRIPTION OF THE APPLIANCE
The main functions of the machine, and its relative parts, are described below, with a view
to ensuring its maximum performance.
COFFEE DISPENSING (K-Kwts-S-M-C-B)
Independent dispensing groups with predosed or manual selections.
Filterholders for one or two cups.
DISPENSING OF HOT WATER AND STEAM (K-Kwts-S-M-C-B)
The machine has one or two steam wands and a hot water dispenser which allows the use
of large milk or water containers thus guaranteeing good general ergonomics.
ELIMINATION OF CALCIUM AND MAGNESIUM SALTS FROM THE WATER
(K-S-M-C-B)
This enables the elimination of scale deposits in the machine thanks to a water softener
that softens the water, eliminating the calcium and magnesium salts contained in it.
The water softener is not incorporated in the machine and has an independent manual
or automatic function.
ELIMINATION OF CALCIUM AND MAGNESIUM SALTS FROM THE WATER
(Kwts)
This enables scale deposits to be removed from the machine.
It consists of an ion exchange resin water softener, completely and automatically managed
by the machine.
AUTOMATIC REGENERATION OF THE WATER SOFTENER RESINS (Kwts)
When the resins in the water softener are used up, all the operator has to do, on receiving
the automatic prompt from the machine, is to load the salt.
During regeneration, the system automatically excludes the water treatment circuit from
the machine water supply, allowing the machine to operate without it.
ELIMINATION OF CHLORINE AND ORGANIC COMPOUNDS FROM THE
WATER (Kwts)
Removes the bad taste and deposits caused by the Chlorine and eliminates bacteria, making
the water purer.
It consists of a silver-loaded activated carbon cartridge fi tted inside the machine,
at the water supply inlet.
The system signals the exhaustion of the cartridge in relation to the volume of water that
it has treated and excludes it automatically from the machine water supply circuit, allowing
the machine to continue operating without it.
CONTROL OF WATER LEVEL IN THE BOILER (K-Kwts-S-M-C-B)
This is done by means of a level probe which controls the water level in the boiler,
topping it up automatically when required.
1
2
3
4
5
6
7
C
gb
57
CONTROL OF WATER TEMPERATURE IN THE BOILER (K-Kwts-S-M-C-B)
This keeps the temperature of the coffees constant as opposed to the temperature
and the pressure of the steam.
Consequently, it also controls the pressure in the boiler.
STABILIZING THE BREWING TEMPERATURE (K-Kwts-S-M-C-B)
Each dispensing group has a heating circuit for brewing water that functions with
a heat exchanger.
This circuit ensures that the dispensing group remains at a constant and optimal temperature
even when it is not being used thanks to the effect of the natural circulation of hot water
owing through the circuit itself.
MEASURING THE BREWING PRESSURE (K-S-M-C-B)
This enables the manual regulation of pump pressure during coffee dispensing.
The pressure is displayed on the gauge clearly visible in the working area.
On the K model, the gauge is fi tted inside the machine.
MEASURING THE BREWING PRESSURE (Kwts)
Through the reading of the display, this enables the manual regulation of pump pressure
during coffee dispensing.
MEASURING THE WATER SUPPLY PRESSURE (Kwts)
Enables automatic protection in the event of a water supply stoppage.
PROTECTION OF THE HEATING ELEMENTS (K-Kwts-S-M-C-B)
This consists of a safety level probe that triggers the cutting off of power to
the heating elements.
Resetting takes place through Basic Programming.
See chapter “G – USE”.
PROTECTION FROM OVERHEATING (K-Kwts-S-M-C-B)
In each of following cases:
- Excessive duration of heating
- Exceeding of maximum allowable temperature value, the heating elements are disabled
and a major fault is reported.
UPPER CUP TRAY (S-M-C-B)
These models are equipped with cup heater trays with the capacity to contain a large
number of cups on various levels and to keep them warm in order to guarantee an excellent
cup of coffee.
The heat is generated by a natural fl ow of hot air from the inside of the machine.
8
9
10
11
12
13
14
15
gb
58
UPPER CUP HEATER TRAY (K-Kwts)
Models equipped with larger cup heater trays and electric heating with automatic
temperature control.
The heating can either be enabled or disabled.
DRIP TRAY (K-Kwts)
Improves the draining and cleaning of the work counter.
Avoids blocking of the drain.
USER ALERTS (S-M-C-B)
The machine can give the user a series of alerts through different LED light on/off combinations
for each coffee dispensing button, on each of the two or three groups on the machine.
Symbols are used in this manual to indicate these alerts as follows:
Group 1 Group 2 Group 3
Led all off:
Led of the long single coffee button of group 1 on with fi xed light:
Led of the long single coffee button of group 1 fl ashing:
Led of the long single coffee button of group 1 slowly fading light:
Slow fl ashing led sequence:
Fast fl ashing led sequence:
USER ALERTS (K-Kwts)
The machine can give the user a series of alerts written in the selected language through
an alphanumeric display arranged along two rows with sixteen characters each.
The writing may be fi xed, scrolling or fi xed but divided over two or more screen displays
if very long: wait and read the complete written message to ensure you fully understand
the alert.
16
17
18
19
gb
59
20
21
BASIC PROGRAMMING (K-Kwts-S-M-C-B)
This enables the implementation of some of the Adjustment, Maintenance and Data
Management functions.
It also facilitates the providing of telephonic assistance.
Basic Programming is the exclusive responsibility of the installer/service technician
or of the owner of the business .
It is carried out using the key provided.
These functions are as follows:
- Selection of the language (K-Kwts)
- Setting of date and time (K-Kwts-S-M-C-B)
- Setting of increase (or decrease) of brewing temperature (K-Kwts-S-M-C-B)
- Storage of measured water hardness (Kwts)
- Selection of softener type (Kwts)
- Programming of coffee doses (K-Kwts-S-M-C-B)
- Programming of night cycle (K-Kwts-S-M-C-B)
- Reset of heating element safety device (K-Kwts-S-M-C-B)
- Rinsing of the water treatment circuit (Kwts)
- Reset of scheduled maintenance call (K-Kwts)
- Reset of activated carbon cartridge changing alert (Kwts)
- Display and reset of coffee production (K-Kwts)
- Display and reset of water consumption (K-Kwts)
SPECIAL PROGRAMMING (K-Kwts)
This allows the personalization of certain machine functions according to important servicing,
marketing or individual end Customer requirements
Special Programming is the exclusive responsibility of the dealer’s specialized technician
who will have been specifi cally trained by ELEKTRA to do so.
Special Programming should be carried out on the dealer’s premises prior to installation.
It is carried out via PC by connecting a special cable to the machine’s electronic control unit
and the ELEKTRA program.
These functions are as follows:
- Setting of preventive maintenance program.
- Activation of start of dispensing only upon reaching the ideal brewing temperature.
- Activation of brewing suitability control according to Italian espresso standards.
- Activation of a maximum time between one regeneration and another (WTS version only).
- Personalization of maximum coffee dispensing time.
- Personalization of the maximum heating element “on” time.
- Personalization of the reset code for the scheduled maintenance call, coffee production
and water consumption.
- Saving and printing of all machine confi guration data.
- Saving and printing of all machine cumulative historical data.
gb
60
UNPACKINGD
Packaging is carried out with the aim of protecting the machine from damage during
transportation.
The packaging materials used are recyclable. They are, therefore, chosen according
to environmental protection criteria and ease of disposal, the latter process being geared
at further integration in productive cycle materials.
Thanks to this mechanism, not only is the volume of waste reduced but a more rational
use of non renewable resources is also ensured.
1) Cut the strap that keeps the box closed.
2) Open the top of the box and remove the shock-proof panels inside, remove the accesso
ries contained inside them and take out the present manual, keeping these articles
to hand for the later phases of use of the appliance.
3)
Remove the nylon bag covering the upper part of the machine and put it in a safe
place out of the reach of children.
4) Working with at least one other person, grasp the base of the machine from inside
the box and remove it by lifting it upwards.
5) Remove any other packaging materials and protections attached to the machine.
6) Hand the packaging materials over to an authorized enterprise for disposal and
recycling.
gb
61
Installation must be carried out exclusively by a specialized technician from the Technical
Assistance Service.
The company Elektra declines any and all responsibility for tampering or interventions
carried out by non authorized persons.
Such intervention automatically renders the guarantee null and void.
ATTENTION: (USA NSF requirements)
The equipment is to be installed to comply with the Basic Plumbing Code of the
Building Offi cials and Code Administration International, Inc. (BOCA) and the Food
Service Sanitation Manual of the Food and Drug Administration (FDA).
ADJUSTING THE FEET (K-Kwts)
Place the machine on the work counter and ensure that it is level, by adjusting the length
of the feet.
Turn the chrome-plated foot counter-clockwise, when viewed from underneath, to lengthen
it and clockwise to shorten it. There are no screws or nuts to be loosened or tightened.
WATER CONNECTIONS (K-S-M-C-B)
The water is fed thanks to a connection with the drinkable water supply at a minimum
pressure of 1.5 bar and a maximum pressure of 4 bar.
Should the water supply pressure exceed 4 bar, install a pressure reducer upline of the
coffee machine / water softener system.
An external check-valve may be required to meet local regulations.
The machine has a fl exible steel-braided connection pipe with a 3/8 female connection,
approx. 1.5 metres in length.
1) Connect the fl exible pipe to the coupling located on the bottom of the machine.
2) If the machine is being installed without a water softener (not recommended unless
a centralized water softening system has been installed) connect the fl exible pipe
to the water supply.
WATER CONNECTIONS (Kwts)
The water is fed thanks to a connection with the drinkable water supply at a minimum
pressure of 1.5 bar and a maximum pressure of 4 bar.
Should the mains pressure exceed 4 bar, install a pressure reducer upline of the coffee
machine/water softener system.
An external check-valve may be required to meet local regulations.
The machine has three fl exible connecting pipes with 3/8 female connections,
approx. 1.5 metres in length.
1) Connect each fl exible pipe to the couplings located on the bottom of the machine.
The three couplings are marked “1”, “2” and “W”.
2) Flush the water supply to ensure that it is clean and after couple to it the fl exible pipe
coming from the “W” coupling.
Do not open the water supply.
INSTALLATIONE
1
2
3
gb
62
WATER SOFTENER CONNECTION (K-S-M-C-B)
If the standard water softener with completely manual valves is to be used,
follow the instructions below.
If semiautomatic or automatic water softeners are to be used, follow the specifi c instructions
provided in the handbooks accompanying the water softeners themselves.
The water softener has a fl exible steel-braided connecting pipe with 3/8 female connections,
approx. 0.7 metres in length, and a semitransparent pipe approx. 0.7 metres in length.
1) Flush the water supply to ensure that it is clean.
Couple the 0.7 metre long fl exible pipe to the water softener inlet (upper valve) and the
water supply.
2) Ensure that the valve levers are in the vertical position.
3) Allow at least 10 litres of water to fl ow through the water softener by turning on the water
supply, turning the upper valve lever counter-clockwise and the lower valve lever slightly
counter-clockwise.
4) Only reclose the lower valve, by turning it to the vertical position, when the water
is clear and colourless.
5) Connect the 1.5 metre long fl exible pipe, previously hooked up to the machine,
to the lower valve of the water softener.
6) Cut the semitransparent pipe into two pieces, one 0.4 metres long and the other 1.3
metres long.
7) Connect the shorter piece to the pipe-end fi tting of the upper valve.
8) Connect the longer piece, rolled up, to the pipe-end fi tting of the lower valve, after ensuring
that the gigleur is well-tightened to the fi tting itself.
9) Turn the lower valve lever counter-clockwise so as to feed the machine.
WATER SOFTENER CONNECTION (Kwts)
The machine must only be used with the three types of special water softener supplied
by ELEKTRA, i.e.:
- 8 litre ELEKTRA water softener
- 12 litre ELEKTRA water softener
- 16 litre ELEKTRA water softener
No other type or brand of water softener may be used with this model.
1) Connect the fl exible pipe connected to coupling “1” on the machine to the corresponding
coupling “1” on the water softener.
2) Connect the fl exible pipe connected to coupling “2” on the machine to the corresponding
coupling “2” on the water softener.
Do not open the water supply.
CONNECTION WITHOUT WATER SOFTENER (Kwts)
Although not recommended, the machine can be used without water softener if necessary.
Contact Technical Assistance.
4
5
6
gb
63
DRAIN CONNECTION (K-Kwts-S-M-C-B)
The machine has a rubber connecting pipe with pipe-end fi tting, approx. 1.5 metres in length.
This pipe must be made to fl ow into a fi xed drain manifold with a minimum internal diameter
of 35 mm located underneath the machine work counter.
The space created by difference in diameter of the two pipes inserted one into the other
must be left free for the venting of air during the discharging of the water.
1) Hook up the rubber pipe from the metal pipe or from the plastic drain box installed
in the machine to the drain manifold located underneath the counter, ensuring that
it does not sag and that it is not strangled.
ELECTRICAL CONNECTIONS (K-Kwts-S-M-C-B)
The machine is equipped with a connecting power cable, approx. 2 metres in length,
with 5 wires of the following colours:
- Green/Yellow: Ground
- Blue: Neutral
- Brown: Phase 1
- Black: Phase 2
- Grey: Phase 3
The wires should, preferably, be connected to a terminal board on the electric switchbo-
ard; if a plug is to be used, it should be an industrial plug with a suffi cient capacity to power
the machine.
The connection may be made without any modifi cation being required to the machine,
either to a single-phase 230VAC power supply or to a triple phase 400VAC N3 power supply,
as follows:
SINGLE-PHASE 230VAC CONNECTION
Hook up the Ground and Neutral wires to the two respective terminals on the electric switch-
board.
Join up the three wires of phases 1, 2 and 3 themshelves and connect them to the single
terminal of the phase present in the electric switchboard.
THREE-PHASE 400VAC N3 CONNECTION
Hook up the Ground and Neutral wires to the two respective terminals on the electric switch-
board.
Connect each of the three wires of phases 1, 2 and 3 to the respective terminals
of the phases present in the electric switchboard.
The wiring diagram and electrical data are shown on the two plates located underneath
the drip tray (K-Kwts-S-M-C) or inside the upper cup tray (B).
7
8
8.1
8.2
gb
64
FILLING THE HYDRAULIC CIRCUITS (K-S-M-C-B)
1) Ensure that the water supply is turned on.
2) Switch on the machine by turning the main switch from position “0” to “1”:
the machine goes on and loads water into the boiler, while powering the heating elements.
FILLING THE HYDRAULIC CIRCUITS (Kwts)
Before switching on the machine, ll the water treatment hydraulic circuit.
Proceed as follows:
1) Open the water softener cap.
2) Open the activated carbon cap and take the cartridge out.
3) Top up with water the cartridge container until the water softener has fi lled up completely
and starts overfl owing.
4) Close the water softener cap.
5) Put the activated carbon cartridge in, top up with water to the brim and reclose.
6) Turn on the water supply.
Now the machine is ready to be switched on and adjusted.
If there are problems in opening the two caps, consult chapter “J – TROUBLESHOOTING”.
9
10
gb
65
11 FLUSHING THE MACHINE (USA NSF requirements)
ATTENTION
The technician in charge of installing the appliance should carry out the following
operations before going to install the equipment at the customer’s.
ATTENTION:
The unit should be fl ushed through prior to putting it into service.
With reference to the hydraulic scheme given below, before putting it into service,
the machine must be fl ushed through as follows:
A) FLUSHING THE DELIVERY GROUP
1) Switch the machine on and make sure that it is up to pressure.
2) Let 5 liters of hot water fl ow from each delivery group N° 18 through the fi lter N° 19
located on the fi lter holder N° 21.
B) FLUSHING THE BOILER
1) Switch the machine on and make sure that it is up to pressure.
2) Switch the machine off.
3) Connect a rubber drainage hose to hot water tap N° 14
4) Open hot water tap N° 14 until the boiler is completely drained of water
(time required: 2 minutes):
Note: it is the boiler pressure that makes the water drain off.
C) FLUSHING THE HEAT EXCHANGERS
1) Remove the upper cup tray.
2) Remove the pipe N° 23 and the injector of heat exchanger N° 8.
3) Remove the upper cap of the heat exchanger N° 8.
4) Wait until the heat exchanger is completely empty.
5) Re-connect the pipes to heat exchanger.
6) Reassemble the upper cup tray.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51

ELEKTRA Professional espresso coffee machines Manuale utente

Categoria
Macchine da caffè
Tipo
Manuale utente