Eneo IPD-72A0003M0B Quick Installation Manual

Tipo
Quick Installation Manual

Questo manuale è adatto anche per

Quick Installation Guide
Thermal Network Camera,
336x256, 25Hz, Audio,
Composite, PoE, IP67
ITB-7SF0075M0A
ITB-7SF0013M0A
ITB-7SF0019M0A
ITB-7SF0035M0A
EN
DE
FR
IT
2
Table of content
Parts supplied ...............................................................................................................5
Part names
.....................................................................................................................6
Installation instructions ...............................................................................................7
Pan & Tilt adjustments .....................................................................................................................................................8
Power supply connections
.......................................................................................................................................... 10
Quick Network Setup ..................................................................................................11
Web viewer description .............................................................................................................................................. 12
Player control & Display
......................................................................................................................................... 12
Video Stream
............................................................................................................................................................... 13
Protocol ......................................................................................................................................................................... 13
PTZ Control
.................................................................................................................................................................. 13
User Manual
............................................................................................................................................................... 13
Setup Menu Table
..................................................................................................................................................... 14
Quick Setup .................................................................................................................16
Information ...................................................................................................................................................................... 16
Users
................................................................................................................................................................................... 16
Add
................................................................................................................................................................................ 17
Edit
.................................................................................................................................................................................. 17
Delete ............................................................................................................................................................................ 18
Date & Time
..................................................................................................................................................................... 18
Current Time
............................................................................................................................................................... 18
New Time...................................................................................................................................................................... 18
Time Zone .................................................................................................................................................................... 18
Day & Time Display ................................................................................................................................................... 19
Network
............................................................................................................................................................................. 19
IPv4 Address
............................................................................................................................................................... 19
IPv6 Address
............................................................................................................................................................... 20
DNS
................................................................................................................................................................................ 20
Further information ....................................................................................................21
3
EN
Safety instructions
General safety instructions
Before switching on and operating the system, rst read this safety advice and the operating instructions.
Keep the operating instructions in a safe place for later use.
Installation, commissioning and maintenance of the system may only be carried out by authorised
individuals and in accordance with the installation instructions - ensuring that all applicable standards and
guidelines are followed.
Protect the devices from water penetration and humidity, since these can cause lasting damage.
Should moisture nevertheless enter the system, under no circumstance switch on the devices under these
conditions, instead send them for examination to an authorised specialist workshop.
The system must never be used outside of the technical specications, since this can destroy it.
The device must be protected from excesses of heat, dust, humidity and vibration.
When separating the system from the voltage supply, only ever use the plug to pull out the cable. Never
pull directly on the cable itself.
Lay the connecting cables carefully and check that they are not mechanically stressed, kinked or damaged
and that no humidity can penetrate into them.
In the event of a malfunction, please inform your supplier.
Maintenance and repairs may only be carried out by authorised specialist personnel.
The system must be isolated from the power supply before opening the housing.
The device may only be opened by qualied service personnel. Unauthorised access invalidates any
warranty claim.
Connection cables should always be exchanged through Videor E. Hartig GmbH.
Use only original spare parts and accessories from Videor E. Hartig GmbH.
The housing should only be cleaned using a mild domestic cleaning agent. Never use solvents or petrol as
these can permanently damage the surface.
During installation, it is essential to ensure that the seals provided are correctly installed and that they are
not displaced during installation. Damaged seals must not be installed and will invalidate any warranty.
The installer is responsible for the maintenance of the enclosure as per the technical data, e.g. by sealing
the cable outlets with silicone.
Wire end ferrules should be used when shortening the exible connection cables.
The devices may only be operated in the temperature range indicated in the data sheet and within the
dened air humidity range.
Product - Specic Safety Instructions
The camera may never be pointed directly at the Sun with the aperture open (this will destroy the sensor).
It is unavoidable that during manufacture and to a certain extent during later use, humidity will be present
in the ambient air within the device’s housing. In the event of large temperature uctuations, this humidity
may condense inside the housing.
To avoid this condensation inside the very tightly sealed housing, the manufacturer has inserted silica gel
sachets in the housing of the various camera types.
It is however a physical given, that these silica gel bags will reach saturation after a certain amount of time.
They should therefore be replaced with new silica gel sachets.
During installation, it is essential to ensure that the seals provided are correctly installed and that they are
not displaced during installation. Damaged seals must not be installed and will invalidate any warranty.
A multipolar, easily accessible isolation device should be installed in the proximity of the IR Spotlight, in
order to disconnect the device from the power supply for service work.
The earth connection must be made according to the low impedance requirement of DIN VDE 0100.
Subsequent painting of the equipment surface can impair the function.
Any warranty claim is invalidated by subsequent painting.
A safety margin of > 1m from the spotlight must be maintained when viewing directly into the IR Spotlight
in a darkened environment.
Do not look directly at invisible LED radiation using optical instruments (e.g. a reading glass, magnifying
glass or microscope), since this can endanger the eyes, LED Class 1M.
Operation of the IR spotlight with a defective cover or during repair is prohibited.
4
Class A device note
This is a Class A device. This device can cause malfunctions in the living area; in such an event, the operator may
need to take appropriate measures to compensate for these.
WEEE (Waste Electronical & Electronic Equipment)
Correct Disposal of This Product (Applicable in the European Union and other European countries with separate
collection systems).
This marking shown on the product or its literature, indicates that it should not be disposed with
other household wastes at the end of its working life. To prevent possible harm to the environment
or human health from uncontrolled waste disposal, please separate this from other types of wastes
and recycle it responsibly to promote the sustainable reuse of material resources. Household users
should contact either the retailer where they purchased this product, or their local government
oce, for details of where and how they can take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase
contract. This product should not be mixed with other commercial wastes for disposal.
Graphical symbols
Please pay attention to the safety instructions, and carefully read through this instruction guide before initial
operation.
Important points of warning are marked with a caution symbol.
i
Important points of advice are marked with a notice symbol.
5
EN
Parts supplied
Camera
Operating Instruction
CD
Mounting Template
Cable Signal Sticker
Plastic Anchor: 6 x 30mm (4x)
Mounting Screw: 4 x 30mm (4x)
Assembly Screw: 4 x 15mm (4x)
Torque Wrench: 3mm (1x)
Coupler for RJ45 Cable (1x)
Wiring Connector: (1x)
Video Sub-Out Cable
Easy Bracket
6
Part names
Sunshield bolt
Ethernet & Power cable
Front case Rear case
Bracket
Easy bracket
Sunshield
Lock/Unlock screw
Micro SD Card slot
IP Reset
USB Connector
COVER OPEN
7
EN
Part names
Sunshield bolt
Ethernet & Power cable
Front case Rear case
Bracket
Easy bracket
Sunshield
Lock/Unlock screw
Micro SD Card slot
IP Reset
USB Connector
Installation instructions
CAUTION: The cameras base should be attached to a structural
object, such as concrete, hard wood, wall stud or ceiling rafter
that supports the weight of the camera. If necessary use appro-
priate mounting material (e.g. anchors) instead of the material
enclosed with the camera.
1. Locate the mounting template at the installation position and drill the ceiling or
wall if needed.
i
The easy bracket can not be installed on the ceiling.
2. Place the easy bracket on pre-drilled position and fix it through using mounting
screws(4x30mm). Skip this step when an easy bracket is not installed.
3. Route the ethernet and power cable to the connecting place. Hook up the
camera bracket with the easy bracket as illustrated below.
4. Fix the camera bracket through using assembly screws (4x15mm).
5. Set the camera’s viewing angle.
6. Put the sunshield to the camera unit and tighten the sunshield-bolts.
8
CAUTION:
Extreme care should be taken NOT to scratch the surface of win-
dow while the camera installing or adjusting.
Care should be taken the cable is NOT to be damaged, kinked or
exposed in the hazardous area.
Do not expose the camera directly to a strong light source such
as the sun or spot light.
Pan & Tilt adjustments
Unlock the screw on the camera bracket through using the torque wrench supplied
Set the cameras viewing angle then lock the screw on the bracket.
1. Pan limit: Pan is limited to +/- 90°.
Assembly Screw: 4x15mm
Torque Wrench
Mounting Screw: 4x30mm
Cable exit
REAR VIEW
9
EN
90
°9
2. Tilt limit: Tilt is limited to 0°(2°) min ~ 90° max. for wall(ceiling) installation respec-
tively with reference to the wall(ceiling) when the inclination of camera module is
0°, that is, the image is aligned horizontally.
90°
88°
3. Inclination limit (Horizontal image alignment): Inclination limited to +/-90° max.
on the wall on the ceiling
10
Adjustment of viewing angle with a bracket
Power supply connections
Make sure the power is removed before the installation. Camera can work with either
24VAC or 12VDC, dual voltage power and PoE (IEEE Std. 802.3af). Primary and secondary
grounds are completely isolated to avoid the possible ground loop problems.
1. Plug the network cable into RJ-45 Ethernet Port. If PoE is the unique power, there
will be no need to connect Power terminal.
2. When DC12V or AC24V Local power is necessary, connect the low voltage (DC12V
or AC24V) rst, then plug the AC adapter to AC outlets to avoid an improper reset
from power jitter and a damage from the surge voltage when no load.
i
When PoE and local dual power are connected at the same time, local power has
priority.
Attach the Signal Assignment Sticker in a visible spot for wiring reference.
Torque wrench
Lock / Unlock
screw
Audio-OUT (Orange wire)
AC24V/DC12V (Red wire)
AC24V/GND (Black wire)
Alarm-IN (Green wire)
Alarm-OUT (Blue wire)
GND (Gray wire)
Audio-IN (Brown wire)
GND (Gray wire)
LAN Cable with
RJ-45 and Protection Cap
BNC
11
EN
Quick Network Setup
1. After the camera is connected to the network, start eneo Site Manager’ tool
(downloadable from www.eneo-security.com).
2. You will get a list of cameras connected to the local network. Highlight your cam-
era in the list and open a context menu with a click of the right mouse button.
3. Select the „Set IP Address [dhcp / static]“ option to open a window for setting the
cameras IP properties. When you are done click the „OK“ button to update the
camera settings.
4. By default the camera is set to DHCP. If there is no DHCP server present in the net-
work the camera will fall back to a default IP address after a while. In this scenario
please only add one camera at a time to the network to avoid conicts due to
identical IP addresses.
The network camera‘s default IP address is: 192.168.1.10.
5. Right clicking the device name in the eneo Site Manager will bring up the context
menu. Use the ‘Open Device Web Site’ option to access the camera.
6. The web viewer login page will open up in your default web browser.
In case of Microsoft Internet Explorer install Active-X named VIDEOR E. Hartig
GmbH according to the instruction at the bottom of the browser.
7. Use the default user name and password to log in.
Default user name: admin
Default password: admin
12
Web viewer description
(A) Menu button: Click the button to show or hide the setup menu bar.
(B) Model name: Show a camera model name connected.
(C) Select Language: Set the web viewer language English, German or French.
(D) Main setup menu bar: Set the camera or network functions.
(E) Camera monitoring window: Display the currently connected camera view or
function.
(F) Log out and exit the web viewer
(G) Help the menu function. Click and pop-up the page about current menu
description.
Player control & Display
(1) Pause: Pauses the live view.
(2) Snapshot: Captures the image in .jpg format with the current stream resolution.
13
EN
(3) Speaker: Enables audio to be output to the audio out port.
(4) Microphone: Enables audio to be input from the audio input port.
(5) Record: (Available with the built-in Storage feature version only) Records the live
video in H.264 format to the equipped storage memory like SD, SDHC or SDXC
from the video stream selected in the RECORD menu.
(6) Window Fit: Display live view to t the window size.
(7) Full Screen: Resizes the live view display to t to the monitor resolution. ESC key
returns to the previous view.
(8) Custom: Selects the live view display scale, 0%~200%, by the control bar. 100% is
the original size.
Video Stream
Selects the video source stream to display the live view only.
Protocol
Selects the network protocol out of HTTP, TCP or UDP.
PTZ Control
(Available with AF version & the built-in motor driven V/F lens version only)
User Manual
Help the menu function.Click and pop-up the page about current menu description.
14
Setup Menu Table
Category Menu Conguration
LIVE VIEW
Player Control
Pause, Snapshot, Speaker, Microphone, Record
Display (Window Fit, Full Screen, Custom)
Video Stream Stream1, Stream2, Stream3
Protocol HTTP, TCP, UDP
PTZ Contol (*) Zoom, Focus, Push AF
PLAYBACK Event Search, Timeline Search, Timeline Bar
SETUP
Information General, System Information, Open source Information
Video & Image
Source
Stream1/2/3, Snapshot
Image
Basic
Sharpness[DDE], Palette,
FFC Warn, Enable ip image,
Enable mirror image
OSD
Enable text OSD, Enable
date&time OSD
AGC
Mode, Auto Preset, Contrast,
Brightness, Filter, SSO, ACE,
Plateau Level, Max Gain
FFC
Mode, Interval (FFC Interval,
Low Gain FFC Interval),
Temperature (Temp Change,
Low Gain Temp Change)
Thermal
Spot Meter (Mode,
Thermometer), Isothermal
(Mode, Threshold Unit,
Upper/ Middle/ Lower
Threshold)
VerticalView Mode, Rotation
Privacy Mask Color, Name
Digital Zoom Level
Audio
Compression, Sample rate, Bitrate, Input Volume, Output Volume, Audio auto activation
on ONVIF access
15
EN
SETUP
Record
Record
Overwrite when storage is full,
Continuous record setting
Schedule
Storage Format, Remove, Storage Information
Event
Triggers
Motion, VCA, Tamper, Alarm In, System, Manual, Network,
Timer, Temperature
Actions
Record, Alarm Out, E-Mail, FTP, Video Boost, Notication
Server
Rules Event Processing, ONVIF Mapping
System
Security User, HTTPS, IP Filter, ONVIF, Video Stream, Export/Import
Date & Time Current Time, New Time, Time Zone, Date & Time Display
Network TCP/IP, DDNS, RTP, UPnP, Zeroconf, Bonjour
Language English, German , French, Polish, Finnish, Korean
Maintenance
Maintain (Restart, Reset, Default), Upgrade, Setup Export,
Setup Import
Log & Report Logs (Database Capacity, Search Condition, Log List), Report
USER MANUAL
LOG OUT
(*) Available only with the built-in Motor driven V/F lens version
16
Quick Setup
Information
Shows the overall information about the system such as Model name, MAC address, IP
address, Zeroconf, IP address, Firmware version, Server time, Running time, CPU usage,
Inbound/Outbound Bandwidth and Open source list.
Users
Manages the user accounts by names, groups and authorities.
Mark ENABLE ANONYMOUS VIEWR LOGIN if anyone is permitted to login anony-
mously. Accessing SETUP menu with the anonymous login will exit and require ID/
Password login.
> USERS : Can be added, edited or deleted.
17
EN
Click the Add, Edit, or Delete button for managing user account.
Add
To add a new user:
1. Click the Add tab, and type a new user name. (1 to 14 alphanumeric characters).
User names are not case sensitive.
2. Type a password and retype conrm password. (1 to 8 alphanumeric characters).
Passwords are case sensitive.
3. Select one of the groups you wish to assign to the user.
4. Click the OK button to save the settings and add a new user.
Edit
To edit a user:
1. Select one of the User Names in the User List you want to modify.
18
2. Click the Edit tab, then new pop-up window appears.
3. Type a password (1 to 8 alphanumeric characters) and retype conrm password.
The user name can’t be modied.
4. Select one of the groups you wish to assign to the user.
5. Click the OK button to save the settings and modify a user.
Delete
To delete a user:
1. Select one of the User Names in the User List you want to remove.
2. Click the Delete tab. A dialog box appears with conrmation message.
3. Click the OK button. The user prole is removed from the User List prole.
Date & Time
Current Time
Shows the current date and time. Clicking SAVE tap updates and saves the date and time
with the selected time in NEW TIME.
New Time
Select one of the following server time.
Synchronize with computer time: Obtains the time from the computer.
Set manually: Sets the date and time manually.
Synchronize with NTP Server: Obtains the time from the assigned NTP server at
every hour in INTERVAL. The NTP servers IP address or host name has to be speci-
ed in the time server.
Time Zone
Select the time zone to be referenced to the NTP server where the camera is installed
Mark AUTOMATICALLY ADJUST FOR DAYLIGHT SAVING CHANGES check box to update
the time automatically with daylight savings
19
EN
Day & Time Display
Select the date & time formats to be displayed.
Network
The DHCP (Dynamic Host Conguration Protocol) server has a feature that automatically
assigns an IP address to the device if there is a device on the network.
IPv4 Address
Obtain IP address via DHCP :
Gets the IP address assigned by the DHCP (Dynamic Host Conguration Protocol) server.
Status:
Allocated’ shows that the IP address is obtained from the DHCP.
20
IP address, Subnet mask, Gateway:
Displays the current IP address which is obtained from the DHCP
Use the following IP address:
Select the choice box if you want to assign the IP address manually.
IPv6 Address
Mark ENABLE check box to use IPv6 address and click SAVE button, then new IPv6 address
will be obtained.
DNS
Obtain DNS address via DHCP :
Obtains the DNS address automatically assigned by DHCP server.
Use the following DNS address :
Requires manual input as per below.
DOMAIN NAME : Enter the domain for the host name
PRIMARY DNS SERVER : Enter the IP address of the primary DNS server.
SECONDARY DNS SERVER : Enter the IP address of the secondary DNS server.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88

Eneo IPD-72A0003M0B Quick Installation Manual

Tipo
Quick Installation Manual
Questo manuale è adatto anche per

in altre lingue