Thank you for purchasing the DIGIWEIGH DW-70 400lb. shipping scale.
Please read all operating instructions carefully before use. Scales are
precision measuring devices and should always be handles with proper care.
To ensure years of reliable service, keep these simple tips in mind:
èDo not exceed the scale's maximum capacity. Overloading your scale can permanently
damage it!
èAvoid exposure to extreme heat or cold. Scales perform best at normal room
temperature. If temperatures have changed dramatically, calibration and adjustment
may be necessary.
èAllow your scale to warm up for 30-60 seconds before performing calibration and
adjustment (if available).
èStore your scale in a clean, dry location. Dust, dirt, and moisture can accumulate on the
weighing sensors and electronics causing inaccuracy or malfunction.
èAvoid using your scale in close proximity to strong radio wave emitting devices such as
computers, cash registers, and cordless phones.
èAlways weigh on a flat and level surface, free from vibrations and drafts. The comer of
a room is usually the most stable.
èGently apply all items to be weighed. Do not drop items onto the weighing platform.
èAvoid dropping your scale. The warranty does not cover damage due to rough
treatment or overload.
èCheck the batteries first if you are having any trouble with your scale. This simple step
can remedy most scale issues.
èDo not disassemble your scale. This product contains no user serviceable parts.
. Package included . Battery Installation
1. Before using the scale for the first time, check the
1. Scale battery compartment andremove any plastic insulation
2. AA Batteries (×3) strips or packaging that may be in place to prevent battery
drainage during shipping/storage.
3. 6V Power Supply
2. If you are replacing the batteries, make sure the
4. Wireless USB adapter/memory card (all in one) positive and negative contacts are properly aligned.
5. Display Mounting KIT
. Structure Description
1. The data cable is hidden at the back of the scale.
Take it out and connect it into the port of the Indicator
before use Key Description
2. The Indicator can be pull ed out and pl ace d
separately.
Ⅲ.Key Description
Ⅴ.Operation
1. Must install the UPS Worldship or Fedex Ship
Manager” software on the computer first.
2. Insert the wireless USB adapter/memory card to the
USB port of the computer.
3. Open the "DIGIWEIGH" file on the USB card from the
computer.
4. Run the appropriate application according to the tool
you use. "UPS WorldShip" selects and run "UPS", FedEx
Ship Manager” selects and run " FedEx ".
5. Take out the data cable from the rear of the scale and
connect it into the data port on the indicator. If use without
the battery, connect the power adapter to the power port of
the indicator.
(CAUTION: Always insert the USB card to the computer
first before turn on the scale if removed, otherwise there is
error may occurred)
Scale
Indicator
Connector Wire
Backlight
ON/OFF Tare Key Mode Key Power
ON/OFF
MODEL: DW-70
Integration of UPS & FedEx
User
Manual
MODEL: DW-70 400x0.1lb/180x0.05kg
853570006923
Youtube Installation
Video
6. Set up the scale on the UPS and Fedex Software: as a negative number.
On the UPS “Worldship, select the scale port as “USB. 3. You may now fill the
container with the quantity
Then the scale type is DIGIWEIGH wireless 400Lb shipping to be weighed. The display
scale. will show the net weight of
the contents.
4. To return to normal
weight display (gross weight), remove any items from the
weighing platform and press the TARE key again to re-zero
the scale.
.Troubleshooting
Problem: Scale will not turn on
Solution: Check the batteries
Problem: Displayed weight fluctuates randomly
On the Fedex “ship Manager Solution: Make sure your workspace is stable and free of
Select “I'm using my own serial scale any air currents or vibration
Problem: Displayed weight is inaccurate
Solution: Perform a calibration adjustment
. Error Codes
1. OUTZ - Zero range has shifted. Perform calibration
adjustment. If the problem persists, the load cell may be
permanently damaged due to overloading.
2. 88888 - Maximum capacity exceeded. Remove the
extra weight to avoid damaging the load cell.
Click Configure Scale, make sure the Port: USB; Scale
3. Lo - Batteries are low. Replace the batteries.
Type Custom; Vendor Id 1446; Product Id 6A73, Then
put the object on the platform and click Test Scale. Also . Calibration
make sure the scale mode on the default unit as “lb
1. The calibration process needs to use 5kg and 25kg
weights, please prepare them before calibration.
2. The indicator needs to be pulled out from the scale
body during calibration.
3. Press and hold the "MODE" key, and release the key
when the indicator displays "0".
4. When the indicator displays "1", place a 5kg weight in
the center of the scale.
5. When the indicator displays "2", remove the 5kg
weight.
6. When the indicator displays "3", place a 25kg weight in
the center of the scale.
7. When the indicator displays "25.00kg", and display
7. Place the scale on a flat, level surface and press the flash twice.
ON/OFF key to turn the scale on.
8. Remove the 25Kg weight and the calibration is
8. Once the start-up process completes, the display will completed.
show zero and ready to weigh.
9. Place the object on the platform and Wait a couple
seconds for the display to stabilize before taking a weight
reading.
Ⅵ.Changing the Unit of Measure
1. Press the MODE key to change the scales displayed
unit of measure.
2. If the scale is turned off then back on, it will default to
the last unit used.
UD Series Units:
kg (kilogram)oz (ounce) Ib (pound)
. Using the Tare Feature
You can use this scale's tare feature to subtract the weight of
an empty container or vessel for net weight determination.
NOTE: The weight of the container will subtract from the
available capacity.
1. Place the empty container or vessel on the weighing
platform.
2. Press the TARE key once. The display will then reset to
zero. If the container is removed, it's weight will be displayed
Don't expose scale to
moisture.
Don't drop or mistreat the
scale.
Don't overload the scale. This
will permanently damage it!
Don't leave weight on the scale
when not in use.
MODEL: DW-70 400x0.1lb/180x0.05kg
User
Manual
MODEL: DW-70
Integration of UPS & FedEx
Youtube Installation
Video
  • Page 1 1
  • Page 2 2

DigiWeigh DW-70 Manuale utente

Categoria
Bilance da cucina
Tipo
Manuale utente

in altre lingue