Our products have been designed and manufactured in
such a way to ensure that all quality, funconality and aes-
thec requirements are met. We would like to congratu-
late you on the purchase of this great product and wish
you a pleasant experience with it.
Electric radiator
Guide to safe installaon
and use.
1. Do not install the heater under an electrical socket
point.
2. Your electric heater should be lled with a carefully
measured amount of liquid. In the case of loss of heat-
ing medium, or in any other case which demands its
supplementaon, contact your supplier.
4User manual TDY www.termaheat.pl
3. The device is not equipped with an external tempera-
ture controller *).
Do not use the device in a small room if unsupervised
disabled or incapacitated individuals are inside it. Only
use the device if those individuals are under constant
supervision.
*) Does not apply to selected models. Ask your supplier for details.
4. Electric heater is not a toy. Children under the age
of 3 should not be allowed within close proximity
of the device without the supervision of an adult.
Children aged 3 to 8 should only be allowed to oper-
ate the heater when it has been properly installed and
connected. The child must be under adult supervi-
sion or have been trained to safely operate the device
while understanding the risks.
5. Note: Some parts of the radiator can be very hot and
can cause burns. Pay special aenon to the presence
of children or people with disabilies.
5
EN
6. If the device is used as a clothes and towel dryer, ensure
that the fabrics drying on it have only been washed in
water, avoiding contact with any harsh chemicals.
7. To ensure the safety of very small children, install
the electric dryer so that the lowest tube is at least
600 mm above the oor.
8. The device should only be installed by a qualied in-
staller in accordance with the applicable regulaons
regarding safety and all other regulaons.
9. All installaons to which the device is connected
should comply with regulaons applicable in the coun-
try of installaon and use.
10. Extension leads or electric plug adapters should not
be used in order to supply power to the heater.
11. While connecng the radiator to electric installaon
ensure that the curcuit has a 30 mA residual-cur-
rent circuit breaker and an appropriate overcurrent
circuit breaker. With the permanent installaon (ca-
ble connecon without plug) it is also mandatory
to provide an omnipolar cut-o switch with a min-
imum contact opening of 3 mm for disconnecng
the device on all poles.
6User manual TDY www.termaheat.pl
12. The device version labelled PB can be installed in bath-
rooms in zone 1, as dened by applicable law, subject
to any addional regulaons concerning electrical in-
stallaons in wet areas.
Other versions of the device can be installed in Zone 2
or beyond.
13. The device is recommended for use solely as de-
scribed in the manual.
14. Ensure that the heater has been installed on a wall in
accordance with its installaon manual.
15. Please forward this instrucon manual to the end
user.
7
EN
Zone 1
Zone 2
8User manual TDY www.termaheat.pl
Electric Heang
Element
Safety requirements
installaon
1. Fing and connecon of the heang element should
only be performed by a qualied installer.
2. Connect the unit to a sound electrical installaon (see
the rangs on the heater).
3. Switching on the heang element in the open air to test
the device is permied for a maximum of 3 seconds.
4. Never test a heang element that is already installed.
Do not turn the heang element on in an empty
radiator!
5. Ensure that the power cord does not touch the hot
parts of the heang element or radiator.
9
EN
6. Before installing or removing the device, make sure it
is disconnected from the power source.
7. Do not open the device any interference with inter-
nal components will invalidate the warranty.
8. The heang elements power output must not ex-
ceed the radiators power output for the parameters
75/65/20° C.
9. The pressure in the radiator should not exceed 10 atm.
Ensure that an air cushion is preserved in electric radi-
ators. In central heang systems, leave one valve open
to prevent pressure build up due to the thermal ex-
pansion of the liquid.
10. The device is intended for home use only.
11. Fing and Installaon of the device must be carried
out in accordance with all local regulaons for elec-
trical safety, including installaon within permissi-
ble locaons only. Observe bathroom electrical zone
regulaons.
10 User manual TDY www.termaheat.pl
Safety requirements use
1. The heang element must be fully submerged in the
heang liquid during its operaon.
2. Regularly check the device for damage to ensure it is
safe to use.
3. If the power cord is damaged the device should not be
used. Unplug the device and contact the manufactur-
er or distributor.
4. Do not allow ooding into the heang element casing.
5. Do not use the heang element in heang systems
where the water temperature exceeds 82° C.
6. The heang element and radiator can heat up to high
temperatures. Please be cauous avoid direct con-
tact with the hot parts of the equipment.
7. Do not open the heang element casing.
8. In the central heang system, always make sure that
one valve of the radiator remains open.
11
EN
9. Ensure that minors aged 8 and above or those with
a physical or mental disability are supervised if operat-
ing the device.
10. The device is not a toy. Keep it out of the reach of
children.
11. The device must be disconnected from the mains dur-
ing cleaning and maintenance.
12. Cleaning of the equipment by children under 8 years of
age is only permied under appropriate supervision.
12 User manual TDY www.termaheat.pl
Intended use of device
The heating element is an electric device
intended solely for installaon in radiators
(standalone or connected to the central
heang system)
Heating element power output should
be matched with radiator output for pa-
rameters of 75/65/20° C
Technical informaon
Model markings
(power cable type):
PB (Straight cable without plug) *
PW (Straight cable with plug)
SW (Spiral cable with plug)
Type of electrical connecon: Y
Heat outputs available: 120, 200, 300, 400, 600, 800, 1000, 1200 [W]
Power supply: 230 V / 50 Hz
Insulaon class: Class I
Towel rail connecon thread: G 1/2"
Casing protecon class [IP]: IPx5
Length of heang element: 120 200 300 400 600 800 1000 1200 [W]
315 275 300 335 365 475 565 660 [mm]
* Device intended to be connected permanently to the system
13
EN
Installaon or removal
Detailed informaon demonstrang the dif-
ferent ways of installing or removing a radi-
ator heang element is available from the
manufacturer or importer (see footnotes at
the end of the manual). Below we list some
basic requirements and principles which
must be followed to ensure long term, relia-
ble operaon of the product.
150°
When the heang element is installed hor-
izontally, it must be rotated to such an ex-
tent that the single tube, which houses the
temperature sensor, is posioned as low as
possible.
Before installaon or rst use:
1. Read the chapter Safety requirements
—Installaon.
2. Fit the heang element using the cor-
rect spanner (size 22).
3. The heang element must be installed
at the boom of the radiator, perpen-
dicular to the radiator pipes, while pre-
serving space for the proper circulaon
of the heang medium.
4. Use a suitable heang medium for ll-
ing the electric radiator, i.e. (water, spe-
cial products based on water and glycol
for use in central heang systems, or oil
which complies with the requirements
of the manufacturer of the radiator and
heang element).
8% (20°C)
14 User manual TDY www.termaheat.pl
5. Check the distances between the indi-
vidual heang element tubes and bend
if necessary.
5 mm
2-3 mm
6. Do not switch the heang element on if
it is not fully immersed in radiator heat-
ing medium.
7. Make sure an adequate air cushion is pre-
sent to protect against excessive pressure
build up within the heater (always leave
one of the radiator valves open).
8. When lling the radiator with hot liquid
insure that the liquid temperature does
not exceed 65° C.
9. Follow the subsequent guidelines when
connecng the electrical installaon:
a. Brown wire — live connecon to the
circuit (L).
b. Blue wire — connect to neutral (N)
c. Yellow & green wire — earth con-
necon (PE).
10. Before filling the radiator with heating
medium, ensure that the heang element
is ed properly and that it is water ght.
11. In central heating installation radiator
must be ed with the valves enabling
disconnecon of the radiator from the
rest of the system.
12. The temperature of the heang agent
in the central heang system must not
exceed 82° C!
13. For detailed installation hints — see
the last pages of this manual.
Notes prior to removal:
1. Before dismantling permanently, discon-
nect the heang element from the mains
and ensure that the radiator is not hot.
2. Be aware. A radiator filled with liquid
can be very heavy. When moving the
radiator, ensure that you take the nec-
essary safety precauons.
3. Before disassembly, close the appropri-
ate valves and drain the radiator com-
pletely to avoid causing any damage.
15
EN
Product disposal
This product should not be disposed of as
general waste but should be brought to the
appropriate collecon point for re- cycling of
electric and electronic devices. This informa-
on is provided by the sign on the product,
user manual and packaging. Informaon on
the appropriate point for used devices can be
provided by your local authority, product dis-
tributor or the store from where the product
was purchased. Thank you for your eort to-
wards protecng the environment.
Maintenance
Before performing maintenance, always
unplug the unit from the mains system.
Periodically check the uid level in the ra-
diator and ensure the heang element is
completely submerged.
Clean the product with a dry or damp
cloth. If necessary, use a very small
amount of detergent, ensuring that it
contains no solvents or abrasives.
16 User manual TDY www.termaheat.pl
TDY
The TDY heang element has 3 temperature
sengs and an automac turn-o switch.
The LED indicator shows, aer each seng
change, the currently set temperature lev-
el as well as me remaining unl the end of
a heang cycle. Each seng change is also
conrmed by a corresponding beep.
The built-in temperature sensor prevents
the radiator from freezing when tempera-
ture falls below 5-7°C.
How to operate TDY
To switch on the heang element, press the
buon. The red LED light, indicates that the
heang element is on and operang. The cor-
responding double beep conrms that the
device has been either switched on or o.
countdown mer display
Red LED indicator
on/o buon
Every me the device is switched on, the
countdown mer is reacvated — 5 blue
LEDs light up. The factory default mer set-
ng is 120 minutes (it is possible to change
the countdown mer range between 60-180
min in the advanced sengs mode).
How to read the countdown mer
The number of lit up, blue LEDs tells you how
much me is le unl the end of the heang
cycle: the me of one LED is equal to 2/10
(20%) of the total countdown me, this is ad-
dionally divided into 2 equal parts when the
LED glows connuously or ashes. This way
temperature seng
countdown mer display
Red LED indicator
on/o buon
17
EN
you can easily read the remaining me le
to the end of the heang cycle to 1/10 (10%)
accuracy. Depending on the preset total op-
erang me (60-90-120-150-180 minutes),
the shortest me indicated by your device
will be 6-18 minutes.
Each LED, rst glows connuously for 1/10
of the set me, and for another 1/10 of the
set me, it ashes and then goes out. The
red LED glows constantly throughout the op-
eraon me unl the unit switches itself o.
Example for default factory seng
(working me = 120 min)
immediately aer switching the device
on, all blue LEDs light up,
aer 12 minutes the last LED starts ash-
ing and aer further 12 minutes the LED
goes out.
Each LED rst glows connuously for 12
minutes, then ashes for further 12 min-
utes and goes out and so on unl the full
heang cycle me is up and the device
turns itself o.
How to set the operang
temperature
To set the operang temperature of the heat-
ing element:
briey press buon — the rst press
puts the heating element into setting
mode — the red LED goes out and a sin-
gle blue LED ashes, indicang the cur-
rent temperature seng,
another press on the buon will change
the temperature — the corresponding
blue LED ashes and a single beep is emit-
ted (characterisc high pitch sound indi-
cates 40°C seng, the remaining two
temperature sengs are indicated by
low pitch sound).
Temperature seng
Display of operang temperature 40°C 50°C 60°C
Each me the temperature seng is changed,
a single, corresponding LED ashes for 3 sec-
onds. Aer the 3 seconds the heang ele-
ment returns to operaon with the new set-
ngs applied- the red LED lights up and the
LED display shows the countdown mer.
Please note: During operaon, it is possible
to change the temperature any number of
mes, seng the new temperature does not
aect the countdown mer. It is possible to
manually turn o the device at any me.
18 User manual TDY www.termaheat.pl
Advanced sengs
How to change the length of countdown me.
when the heang element is on, press
and hold buon for 5 seconds - ash-
ing red light and a single beep indicate
that the element goes into seng mode,
— use the buon to select the desired
length of countdown me a single beep
conrms the change of seng (charac-
terisc high pitch sound indicates the
shortest countdown me seng = 60
minutes).
Seng the
countdown me
9060 120 150 180 min
Aer a short me, the heang element
automacally returns to operaon with
the new sengs applied — the red LED
lights up and the LED display shows the
countdown mer.
How to enable/disable sound
nocaons
When the heang element is o, press and
hold buon for 5 seconds — special triple
beep conrms the change of sengs:
sound nocaon is enabled and con-
firmed by the following sequence of
sounds: low-low-high.
sound nocaon is disabled and con-
firmed by the following sequence of
sounds: high-high-low.
Troubleshoong
Please note: The control system of the heat-
ing element acvates it only when the radi-
ator temperature is lower than the set tem-
perature. When the required temperature
is reached, the heang element will then
switch itself on and o automacally, only to
maintain the set temperature. Consequently,
the electricity consumpon is signicantly
lower than the theorecal calculaon based
on the nominal power of the heang element.
The design as well as the physical character-
iscs of various heang media may cause
uneven temperature distribuon inside the
radiator, including the case where the lower
radiator tubes may be cold. Such occurrence
is completely normal and does not indicate
fault of the heang element.
19
EN
Problem Possible cause Problem soluon
Heang element is con-
nected to the mains but
no LEDs lights up.
Mains
connecon.
Check the cable for damages and if the
device is properly plugged in. Check the
plug and the socket.
Heang element does
not heat up. LEDs light
up alternately and
evenly
Overheang
Make sure the power output of the heat-
ing element does not exceed the rec-
ommended heang output of a radiator.
Check and reduce the temperature of the
heang medium inside the central heang
installaon (it cannot be higher than 82°C)
If the radiator is not connected to the cen-
tral heang installaon, make sure it has
been properly lled with heang medium.
Heang element does
not heat up. LEDs light
up alternately and
unevenly
Damage to the
temperature
sensor
Disconnect the device from the power
supply, wait unl it cools down, connect
the device back to the power supply.
If the problem persists, contact your supplier.
20 User manual TDY www.termaheat.pl
Warranty terms & condions
1. The subject of this warranty is a Terma
electric heating element with control
head. The product name and character-
iscs are specied on the packaging.
2. By accepting the device on purchase,
the Client conrms that the product is
of full value. The Client should imme-
diately inform the Seller of any discov-
ered faults — otherwise it will be un-
derstood that the Product was faultless
at the me of purchase. This refers es-
pecially to any faults or damages of the
control panel case.
3. The Warranty for period for the Product
is 24 months from the date of purchase,
but no longer than 36 months from the
date of producon.
4. Any claims made will be processed on
production of the warranty card and
the evidence of purchase. The manu-
facturer has the right to reject any claim
on the grounds of failure to present any
of the above documents.
5. This warranty does not cover any faults
that are due to:
— incorrect (not in accordance with
the manual) installation, use or
disassembly,
incorrect use of the heating ele-
ment (i.e. for any purpose that is not
specied by the Manufacturer as in-
tended for this type of product),
Product being handled by unauthor-
ized persons,
— Faults or damages caused by the
Client after having purchased and
accepted the Product.
6. The Central Heang installaon should
be fitted with lock-shield valves, ena-
bling disassembly of the radiator or the
heating element and its control head
without the necessity of emptying the
whole system of the heang agent. Any
problems or expenses arising from the
absence of lock-shield valves in your in-
stallaon cannot be used as grounds for
any claims against Terma.
7. The aached Product Manual is an in-
tegral element of the Warranty. Please
read it carefully prior to the installaon
and use of the Product.
8. The Manufacturer is obliged to remove
any producon fault within 14 working
days of receipt of the faulty device at
the Manufacturers premises.
9. Should the repair be impossible, then
the manufacturer is obliged to replace
the faulty Product with a new, full-value
unit of idencal parameters.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100

Terma grzałki TDY Manuale del proprietario

Tipo
Manuale del proprietario