CARLO GAVAZZI NA13D230CG Guida d'installazione

Tipo
Guida d'installazione

Questo manuale è adatto anche per

Manuale Utente / User Manual
Manuale Utente / User Manual
MODULO DI SICUREZZA
MODULO DI SICUREZZA
SAFETY
SAFETY
MODULE
MODULE
NA13D
NA13D
INTRODUZIONE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
FUNZIONI DELLA CENTRALINA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
INSTALLAZIONE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Avvertenze . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Cablaggio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Alimentazione . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Ingressi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Circuito di riarmo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Uscite sicure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Uscita ausiliaria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
FUNZIONAMENTO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
MESSA IN SERVIZIO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
PRECAUZIONI DI UTILIZZO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
CONTROLLI PERIODICI E MANUTENZIONE . . . . . . . . . . . . . . . . . . . . . . . . . . .6
APPLICAZIONI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
FIGURE E TABELLE / FIGURES AND TABLES . . . . . . . . . . . . . . . . . . . . . . . . .11
DATI TECNICI / TECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
INDICE / T
INDICE / T
ABLE OF CONTENTS
ABLE OF CONTENTS
2
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
FUNCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
START Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Safety Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Auxiliary Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
OPERATING MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
TEST & ACTIVATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
USAGE PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
INSPECTIONS AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
APPLICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
FIGURE E TABELLE / FIGURES AND TABLES . . . . . . . . . . . . . . . . . . . . . . . . .11
DATI TECNICI / TECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
INTRODUZIONE
Il presente manuale utente deve
essere letto e compreso intera-
mente dal personale che si occupa
tutte le attività riguardanti il modulo
di sicurezza NA13D.
Tutte le operazioni devono essere
eseguite esclusivamente da perso-
nale specializzato, che si deve
attenere alle indicazioni in esso
riportate. La valutazione dell’ade-
guatezza del modulo all’applicazio-
ne è responsabilità dell’utilizzatore.
FUNZIONI DELLA
CENTRALINA
Il modulo di sicurezza NA13D con-
trolla dispositivi di arresto di emer-
genza (E-STOP) o chiusura portel-
li in accordo alla Direttiva
Macchine 98/37/CE.
NOTA
I terminali di ingresso delle cen-
traline si intendono:
Azionati o attivati nel caso in
cui il dispositivo di ingresso pre-
senti i due contatti NO chiusi (es.
con E-STOP non premuto). In
questa condizione il modulo di
sicurezza è abilitato a chiudere le
uscite sicure.
Disazionati o disattivati nel
caso in cui il dispositivo di ingres-
so presenti i due contatti NO
aperti (es. con E-STOP premuto).
In questa condizione il modulo di
sicurezza non è abilitato a chiu-
dere le uscite sicure ed i telerutto-
ri esterni non possono essere ali-
mentati.
INSTALLAZIONE
AVVERTENZE
- Installare il modulo nel rispetto
delle normative applicabili nel
paese di utilizzo, con impianto
disalimentato ed in assenza di
pericoli per l’operatore, sul qua-
dro elettrico (grado minimo di
protezione pari ad IP54), in
luogo asciutto e pulito, montato
sull’apposita guida DIN.
- Eventuali manomissioni del
modulo possono determinare
pericolo per l’operatore e causa-
no il decadimento della garanzia.
- Mantenere separati i conduttori
di segnale dai conduttori di
potenza.
- Evitare l’installazione durante
tempeste o temporali.
- Non disperdere nell’ambiente
l’imballo.
CABLAGGIO
Un corretto cablaggio prevede l’im-
piego di conduttori di sezione e
lunghezza adeguata alle caratteri-
stiche dei morsetti, alle correnti ed
alle distanze in gioco, la cui posa
deve evitare rischi di taglio, di
schiacciamento, di eccessiva ten-
sione e di intralcio a persone e
cose.
ALIMENTAZIONE
Collegare i morsetti A1 ed A2 alla
sorgente di alimentazione.
3
4
INGRESSI
Collegare un ingresso NO tra i
morsetti S11-S12 ed il secondo tra
i morsetti S21-S22.
Il modulo deve essere collegato a
due contatti S1 ed S2 (NO), i quali
sono azionati a E-STOP non pre-
muto.
CIRCUITO DI RIARMO
Il modulo è configurato con moda-
lità di riarmo non controllato: è
possibile impiegare, tra i morsetti
S33 ed S34, un pulsante NO (il cui
guasto di incollaggio non viene
rilevato) per il riarmo manuale
oppure un ponticello (cortocircui-
to) per il riarmo automatico.
USCITE SICURE
Sono disponibili come contatti
puliti i morsetti 13-14, 23-24, 33-
34 chiusi in condizioni di modulo
alimentato, correttamente funzio-
nante, di contatti in ingresso chiu-
si e START attivato secondo le
modalità indicate nel presente
manuale.
USCITA AUSILIARIA
Tra i contatti 41-42 è disponibile
un contatto pulito NC impiegabile
come contatto di segnalazione e
non di sicurezza.
FUNZIONAMENTO
Se impiegato con riarmo manuale,
alla chiusura del contatto di
START, con S1 e S2 azionati, il
modulo chiude le uscite sicure ed
apre l’uscita ausiliaria.
Con riarmo automatico, invece,
l’azionamento sia di S1 che di S2
determina la chiusura delle uscite
sicure e l’apertura dell’uscita ausi-
liaria.
I LED CH 1 e CH 2 si accendono
in corrispondenza della chiusura
delle uscite sicure.
Il rilascio anche di un solo contat-
to in ingresso (S1 e/o S2) determi-
na l’immediata apertura delle usci-
te sicure, la chiusura della uscita
ausiliaria e lo spegnimento del/dei
LED relativi.
Una successiva richiusura delle
uscite sicure è possibile solo dopo
aver rilasciato e nuovamente azio-
nato entrambi i contatti in ingresso
(ed attivando lo START, nel caso
di riarmo manuale).
Uguale intervallo deve trascorrere
tra l’apertura del pulsante di
START e la sua richiusura nel
caso di chiusura degli ingressi a
START già premuto.
Inoltre un eventuale incollaggio
del pulsante NO di START blocca
il modulo, impedendo la chiusura
delle uscite sicure.
MESSA IN SERVIZIO
Deve essere fatta ad ogni installa-
zione, modifica nel cablaggio e
periodicamente, eseguendo tutte
ed in sequenza le fasi di seguito
descritte, in condizione di assenza
di pericoli per gli operatori.
FASE 1 Controllare l’integrità, l’in-
stallazione, il posizionamento e il
corretto funzionamento di tutti i
dispositivi in ingresso o uscita del
modulo, nonché lo stato dei
cablaggi.
FASE 2 Alimentare il modulo: il
LED POWER si accende, e resta
acceso in tutte le fasi successive,
mentre i LED
CH1 e CH2 sono
spenti. Le uscite sicure sono aperte
mentre l’uscita ausiliaria è chiusa.
Azionare i contatti sugli ingressi: le
uscite sicure sono aperte, i LED
CH1 e CH2 sono spenti (in caso di
riarmo automatico, CH1 e CH2
sono accesi, le uscite sicure chiu-
se).
Chiudere il contatto di START: le
uscite sicure sono chiuse, i LED
CH1, CH2 sono accesi.
FASE 3 Rilasciare entrambi i con-
tatti di ingresso: le uscite sicure
aprono ed i LED CH1, CH2 sono
spenti.
Durante la F
ASE 2, verificare che,
in configurazione di riarmo manua-
le, il solo azionamento degli
ingressi, senza la chiusura del
contatto di START, non determini
la chiusura delle uscite sicure.
F
ASE 4
(Questa fase deve opera-
re prima su un contatto di ingresso
e poi sul secondo).
Rilasciare ed azionare entrambi i
contatti di ingresso (e premere il
pulsante di START, in modo che le
uscite sicure siano chiuse); rila-
sciare un solo contatto in ingresso
(o scollegare il relativo conduttore)
e verificare che le uscite sicure
siano aperte ed il LED di canale
relativo sia spento.
Premere il pulsante di START, veri-
ficando che le uscite sicure non
chiudano.
Azionare di nuovo quindi il contat-
to rilasciato (o ricollegarne il relati-
vo conduttore) e premere il pulsan-
te di START, verificando che le
uscite sicure non chiudano.
Ripetere per ciascun dispositivo
collegato sugli ingressi tutte le
operazioni dalla F
ASE 3.
NOT
A
Durante le fasi indicate, verificare
che l’uscita ausiliaria sia chiusa
con uscite sicure aperte e aperta
con uscite sicure chiuse.
PRECAUZIONI DI UTILIZZO
- Il controllo di teleruttori esterni o
moduli di espansione è possibile
mediante l’inserimento dei con-
tatti NC di controllo di questi ulti-
mi in serie al pulsante NO di riar-
mo (oppure al ponticello di cor-
tocircuito, nel caso di riarmo
automatico) tra i morsetti S33-
S34.
- È consigliabile collegare in serie
alle uscite sicure un fusibile, per
ridurre il rischio di saldatura dei
contatti delle uscite stesse
(vedere dati tecnici uscite).
5
6
- Non collegare mai circuiti spe-
gniscintilla in parallelo ai contat-
ti di uscita sicuri: non verrebbe
più garantita la funzione di sicu-
rezza.
- Non eccedere mai limiti indicati
nei dati di targa del presente
manuale.
CONTROLLI PERIODICI E
MANUTENZIONE
L’integrità del modulo di sicurezza
va verificata con controlli periodici,
la cui corretta effettuazione e fre-
quenza rientra nella valutazione
dei rischi dell’impianto e nelle
responsabilità di chi è addetto a
tale valutazione.
I controlli periodici consistono nel-
l’effettuare tutte le operazioni pre-
viste del paragrafo MESSA IN
SERVIZIO.
In particolare è necessario effet-
tuare periodici test a bordo mac-
china per verificare che i dispositi-
vi in ingresso al modulo non siano
guasti.
In caso di spegnimento della mac-
china è necessario ripetere tutte
le operazioni indicate nel paragra-
fo “Messa in Servizio”, al fine di
verificare l’integrità del modulo e
di tutti i dispositivi ad esso colle-
gati.
Il modulo non prevede manuten-
zione interna. È necessario, perio-
dicamente ed a macchina e
modulo disalimentati, pulire il
modulo di sicurezza ed i relativi
dispositivi di comando e di attua-
zione, eliminando polvere, liquidi
e condense.
APPLICAZIONI
Nelle figure di esempio l’aziona-
mento di S1 e S2 abilita (riarmo
manuale) o determina (riarmo
automatico) la chiusura delle usci-
te sicure.
In Figura 2, il collegamento del
modulo prevede l’impiego di un
pulsante di arresto di emergenza
(E-STOP) a due canali: a E-STOP
non premuto le uscite sicure chiu-
dono non appena il pulsante di
START viene premuto. Premendo
il pulsante di E-STOP le uscite
sicure aprono.
In Figura 3, il modulo impiega il
pulsante di arresto di emergenza
(E-STOP) a due canali per taglia-
re l’alimentazione, avendo corto-
circuitato i due canali di ingresso.
7
INTRODUCTION
This user manual must be read
and completely understood, prior
to carrying out any operation on
the module, by personnel dealing
with all the activities of the
NA13D
safety module.
All the operations described in this
manual must be carried out exclu-
sively by specialised personnel by
carefully following all the indica-
tions given.
The user decides under his com-
plete resposability that the safety
module is suited for the application.
FUNCTION
The safety module can be emplo-
yed to control E-STOP pushbutton
and limit switch devices, according
to 98/37/CE Machinery Directive.
NOTE
The input terminals of the module
are intended to be:
operated when the input NO
contacts are closed (E-STOP not
pushed). If the module is correctly
supplied and there are not fault
conditions of the safety system
the module is enabled to close
the safety outputs and the exter-
nal contactors can be energized.
released when the input N.O.
contacts are open (E-STOP
pushed). The module is not ena-
bled to close the safety outputs
and the external contactors can-
not be energized.
INSTALLATION
WARNING
- The safety module must be
installed following the standards
in force in the country of use,
when the machine is not powe-
red and with no dangers for the
operator, on the machine’s elec-
trical board in a dry and clean
place (minimum protection
degree: IP54), fixed on the spe-
cial DIN rail.
- If the safety module is tampered
with, it can not ensure the safety
of the operator any more and
the warranty is void.
- To avoid interference due to
coupling, run the connecting
conductors separately from the
power conductors.
- Avoid installation during storms.
- Do not dispose of the packaging
in the environment.
WIRING
It is recommended to use conduc-
tors with section and length ade-
quate to the terminals, currents
and distances involved, ensuring
that the conductors are not exces-
sively tight, that their positioning
avoids potential cuts or squashing
and that they are not in the way of
people or things.
module.
POWER SUPPLY
Connect the A1 & A2 terminals to
the AC / DC power supply source.
8
INPUT
Connect one NO input contact to
the S11-S12 terminals, and the
other to the S21-S22 terminals.
The module must be connected to
two switches/contacts S1 and S2
(NO), which are operated when the
E-STOP button is not pushed.
START CIRCUIT
The unit is set up with not-control-
led automatic/manual START. The
module can be used connecting
between the S33-S34 terminals
either a NO START pushbutton (for
not monitored manual START) or a
short-circuit (for automatic
START).
SAFETY OUTPUTS
Three NO voltage free safety out-
puts are available between the 13-
14, 23-24 and 33-34 terminals:
their contacts are closed when the
safety module is correctly powe-
red, the input switches are opera-
ted, and the START circuit has
been activated, as described in
this user manual.
AUXILIARY OUTPUT
An auxilary NC voltage free relay
output is available between the 41-
42 terminals. It must be used only
for signalling functions and not for
safety functions.
OPERATING MODE
With manual START configuration,
the safety outputs close, if S1 & S2
are operated, when the NO START
pushbutton is pushed. With auto-
matic START configuration, the
safety outputs close (and the auxi-
liary output opens) as soon as both
S1 & S2 switches are operated.
The CH1 & CH2 LED turn on.
Releasing even one input contact
(S1 and/or S2) forces immediately
the safety outputs to an open sta-
tus (the auxiliary output closes).
The LED relative to the channel
whose input has been released
turns off.
A new operating cycle is possible
only after releasing both input con-
tacts and then operating them
again (and pushing the START
button, if the safety module has
been set up with manual START
configuration).
The same delay is necessary bet-
ween the START button releasing
and re-operating, if the input termi-
nals have been previously opera-
ted with the START button already
pushed.
In the models with monitored
manual START configuration, if the
NO START button gets welded, the
safety outputs cannot close their
contacts any more.
TEST & ACTIVATION
The following operations must be
repeated when the module is
installed and every time the wiring
is changed and at regular intervals
by carrying out in sequence all the
steps described below without any
type of dangerous condition for the
operators.
STEP 1 Check the integrity, the
correct installation, the correct
positioning on the machine and the
correct functioning of all the devi-
ces connected to the inputs and to
the outputs of the module. Check
also the correct wiring of all the
devices.
STEP 2 Power on the safety
module: the POWER LED turns on
(this LED has to be considered ON
in all the steps of this sequence).
The
CH1 and CH2 LEDs are off,
the safety outputs open and the
auxiliary output is closed.
Operate the input contacts: the
safety outputs are open and the
CH1 & CH2 LEDs are off (if the
module is configured for automatic
START,
CH1 & CH2 LEDs turns
on, the safety outputs close).
Close the START contact: the
safety outputs close and the
CH1,
CH2 LEDs turn on.
STEP 3 Release both input con-
tacts: the safety outputs open and
the
CH1, CH2 LEDs turn off.
During STEP 2 check that the
safety outputs do not close - with
manual START configuration - sim-
ply operating both input contacts,
without pushing the START
pushbutton.
STEP 4 (This step must be perfor-
med first on one input contact, then
on the other one)
Release and operate the input
contacts and push the START but-
ton, so that the safety outputs
close.
Release only one input contact (or
unconnect the relative wire) and
verify that the safety outputs open.
Push the START button and verify
that the safety outputs do not
close.
Operate the released contact (or
re-connect the relative wire) again
and push the START button, veri-
fying that the safety outputs do not
close.
The STEPS 3 and 4 must be
repeated for each input device
connected to the input terminals.
NOTE
During all steps verify that the
auxiliary output is closed when
the safety outputs are open and
that the auxiliary output is open
when the safety outputs are clo-
sed.
USAGE PRECAUTIONS
- The safety module can check
the integrity of external contac-
tors or expansion modules sim-
ply connecting their NC control
contacts in series to the START
contact (or to the bridge, in auto-
matic START configuration) bet-
ween S33-S34 terminals.
9
10
- It is recommended to connect a
fuse in series to the safety out-
puts to reduce the risk of the
safety outputs contacts welding
(see outputs technical data).
- Never, in any situation,connect
spark quenching unit circuits in
parallel to safety outputs con-
tacts: the safety function would
no longer be guaranteed.
- Never, in any circumstance,
exceed the electrical ratings sta-
ted in the technical data table of
this manual.
INSPECTIONS AND
MAINTENANCE
The integrity of the module and of
all the connected devices must be
checked regularly according to the
risk evaluation of the plant, under
the complete responsibility of the
user. Regular inspections must be
performed repeating all the opera-
tions listed in the TEST & ACTIVA-
TION section.
In particular it is necessary to per-
form regular tests on board in
order to verify that the input devi-
ces are not faulted.
In the event of a switch-off of the
module or of the machine it is
necessary to repeat all the opera-
tions listed in the TEST & ACTIVA-
TION section in order to verify the
integrity of the module + external
device system.
The safety module doesn’t require
internal maintenance: it must be
periodically cleaned - with plant
and module powered off - together
with all the connected devices,
removing dust, liquids and conden-
sation.
APPLICATIONS
In the application samples when
S1 and S2 are operated, the safe-
ty module is enabled to close the
safety outputs (manual START) or
closes the safety outputs (automa-
tic START).
In Fig. 2 a dual-channel E-STOP is
connected to the input terminals.
When the E-STOP is not pushed,
the safety outputs are enabled to
close. The safety outputs are for-
ced to open when the E-STOP is
pushed.
In Fig.3 a dual-channel E-STOP is
connected between the supply ter-
minals and the supply source with
the input terminals short-circuited.
When the E-STOP is not pushed,
the safety outputs are enabled to
close. The safety outputs are for-
ced to open when the E-STOP is
pushed.
FIGURE E TABELLE / FIGURES AND TABLES
11
Fig. 1 - Schema circuitale dei moduli NA13D / NA13D circuit diagram
Fig. 2: NA13D - Applicazione / wiring Fig. 3: NA13D - Applicazione / wiring
12
DA
TI TECNICI /
TECHNICAL
DATA
CARATTERISTICHE / CHARACTERISTICS
Tensione di alimentazione /
Power supply voltage
24 Vac -15/+10% 50 ÷ 60Hz,
24 Vdc -15/+10%
Assorbimento / Current drain 70 mA (@ 24Vdc, a vuoto/no load)
Potenza assorbita / Power Drain max 5 VA
Categoria sic. / Safety Category 4 (EN 954-1)
Categoria / Category E-STOP 0
Protezione al corto circuito /
Short-Circuit Protection
PTC interno / Internal PTC
INGRESSI / INPUTS
Funzione / Function
2 NO senza potenziale /
2 NO Voltage free
Corrente / Input current
max 130 mA (S11-S12)
max 50 mA (S21-S22)
commutaz. / switching: max 950 mA
Fig. 4 - Diagramma funzionale / Functional diagram
TERM COLLEGAMENTI / CONNECTIONS
A1-A2 Alimentazione AC/DC / AC/DC supply
S33-S34
Contatto di START e ritorno teleruttori esterni /
START and feedback terminals
S11-S12 Canale di ingresso NO / NO Input channel
S21-S22 Canale di ingresso NO / NO Input channel
13-14
23-24
33-34
Uscite sicure / Safety outputs
41-42 Uscita ausiliaria NC / NC auxiliary output
Tab. 1 - Funzioni dei terminali / Terminals description
Fig.5 - Etich fron-
tale / Front label
13
USCITE SICURE / SAFETY OUTPUTS
Funzione / Function
Contatti NO a guida forzata /
NO Force-Guided Contacts
Caratteristiche / Ratings (carico
resistivo / resistive load)
230/240 Vac 50/60 Hz - 250
Vdc / 6A / 1380 VA
Protezione dei contatti /
Output contacts protection
Fusibile esterno / External fuse:
4A rit./delayed or 5A rapido/fast
Vita meccanica / Mechanical Life
> 10
7
commutazioni / cycles
Vita elettrica (con max carico)
Electrical Life (with max. load)
> 10
5
commutazioni / cycles
USCITA AUSILIARIA / AUXILIARY OUTPUT
Funzione / Function NC pulito / voltage free
Caratteristiche / Ratings (carico
resistivo /
resistive load)
230/240 Vac 50/60 Hz - 250
Vdc / 6A / 230 VA
TEMPORIZZAZIONI / TIMINGS
Ritardo all’apertura / Response time
(da ingresso aperto ad uscita aperta
/ from input open to outputs open)
max 30 ms
Ritardo alla chiusura / Output ope-
rating time
(da ingressi azionati ad
uscita chiusa / from input operated
to output contacts closed)
max 150 ms
Contemporaneità (alla chiusura)
tra gli ingressi / input channel simul-
taneity (during outputs closing)
infinita / infinite
SEGNALAZIONI A LED / LED WARNINGS
POWER (ON / OFF) Alimentazione /supply ON / OFF
CHANNEL1 & CHANNEL2 (ON /
OFF
)
Uscite chiuse o aperte / Outputs
closed or open
CARATTERISTICHE MECCANICHE ED AMBIENTALI
MECHANICAL AND ENVIRONMENTAL CHARACTERISTICS
Contenitore e morsetti / Housing
and terminal blocks
PA 66 autoesting. VO-UL94 /
PA 66 flammability cl. VO-UL94
14
Fissaggio / Fixing Guida / rail OMEGA - EN 50022
Grado di protezione del modulo /
Module Protection degree
IP30
Compatibilità elettromagnetica /
EMC compatibility
EN 61000-6-2; EN 61000-6-3;
Umidità relativa di esercizio e
stoccaggio / Relative operating
snd storage humidity
10 ÷ 95 %
Dimensioni esterne / Dimensions 99 x 22.5 x 115 mm
Peso / Weight 200 g
RACCOMANDAZIONI / WARNING
Temperatura di esercizio
Operating temperatur
[-25 ÷ 65] °C
“Surrounding Air Test” (UL508):
65°C
Sezione e tipo dei conduttori col-
legabili ai morsetti
Cross-Section and type of the
cables to connect to the terminals
0.05 ÷ 3 mm
2
(AWG 30 - 12)
Rigido e flessibile in rame 60°C /
o 75°C / stranded or solid wire
60° or 75°C copper conductor
Coppia di serraggio dei morsetti
superiori ed inferiori / Torque set-
ting on upper and lower terminals
Superiori / Upper
0.4 - 0.5 Nm (4 LbxIn)
Inferiori / Lower
0.5 - 0.8 Nm (5-7 LbxIn)
Luogo di installazione
Installation location
minimo IP54 con grado di inqui-
namento 2 /
minimum IP54 with
pollution degree 2
Tipologia di prodotto
Product Type
“OPEN TYPE” (UL508)
NOTES
15
16
CARLO GAVAZZI si riserva il diritto di apportare modifiche senza preavviso
CARLO GAVAZZI reserves the right to make changes without prior notice
8020763 - Mod. NA13D
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

CARLO GAVAZZI NA13D230CG Guida d'installazione

Tipo
Guida d'installazione
Questo manuale è adatto anche per