ESAB LHF 630 Manuale utente

Categoria
Sistema di saldatura
Tipo
Manuale utente

Questo manuale è adatto anche per

Valid for serial no. 906--xxx--xxxx0455 675 027 050816
LHF 250, LHF 400,
LHF 630, LHF 800
104
Instruction manual Èíñòðóêöèÿ ïî ýêñïëóàòàöèè
-- 2 --
Rights reserved to alter specifications without notice.
Îñòàâëÿåì çà ñîáîé ïðàâî èçìåíÿòü ñïåöèôèêàöèþ áåç ïðåäóïðåæäåíèÿ.
Ðóññêèé 3...............................................
ENGLISH 9..............................................
Ðóññêèé
TOCr
-- 3 --
1 ÒÅÕÍÈÊÀ ÁÅÇÎÏÀÑÍÎÑÒÈ 4........................................
2 ÂÂÅÄÅÍÈÅ 4.......................................................
3 ÒÅÕÍÈ×ÅÑÊÈÅ ÄÀÍÍÛÅ 5.........................................
ÑÒÀÍÎÂÊÀ 6.......................................................
4.1 Ïîäêëþ÷åíèå ê ýëåêòðîñåòè 6..............................................
5 ÝÊÑÏËÓÀÒÀÖÈß 7..................................................
5.1 Óïðàâëåíèÿ è ðàçú¸ìû 7...................................................
6 ÎÁÑËÓÆÈÂÀÍÈÅ 7.................................................
7 ÇÀÊÀÇ ÇÀÏÀÑÍÛÕ ×ÀÑÒÅÉ 8.......................................
ÈÍÑÒÐÓÊÖÈÈ ÏÎ ÑÁÎÐÊÅ 15.........................................
ÑÕÅÌÀ 16..............................................................
ÑÏÈÑÎÊ ÇÀÏÀÑÍÛÕ ×ÀÑÒÅÉ 21........................................
bh10d2r -- 4 --
1 ÒÅÕÍÈÊÀ ÁÅÇÎÏÀÑÍÎÑÒÈ
ÏÐÎ×ÒÈÒÅ È ÏÎÉÌÈÒÅ ÈÍÑÒÐÓÊÖÈÞ ÏÎ ÝÊÑÏËÓÀÒÀÖÈÈ ÏÅÐÅÄ ÒÅÌ, ÊÀÊ ÏÎ ÄÊËÞ×ÈÒÜ
ÎÁÎÐÓÄÎÂÀÍÈÅ È ÍÀ×ÀÒÜ ÐÀÁÎÒÓ
ÇÀÙÈÒÈÒÅ ÑÅÁß È ÎÊÐÓÆÀÞÙÈÕ !
ÏÐÅÄÓÏÐÅÆÄÅÍÈÅ !
ÄÓà ÎÂÀß ÑÂÀÐÊÀ È ÐÅÇÊÀ ÌÎÃÓÒ ÏÐÈ×ÈÍÈÒÜ ÂÐÅÄ ÂÀÌ È ÎÊÐÓÆÀÞÙÈÌ. ÏÐÈÌÈÒÅ
ÍÅÎÁÕÎÄÈÌÛÅ ÌÅÐÛ ÁÅÇÎÏÀÑÍÎÑÒÈ ÏÐÈ ÏÐÎÂÅÄÅÍÈÈ ÑÂÀÐÎ×ÍÛÕ ÐÀÁÎÒ.
ÎÇÍÀÊÎÌÜÒÅÑÜ Ñ ÒÅÕÍÈÊ ÎÉ ÁÅÇÎÏÀÑÍÎÑÒÈ, ÐÀÇÐÀÁÎ ÒÀÍÍÎÉ ÍÀ ÂÀjÅÌ ÏÐÅÄÏÐÈßÒÈÈ.
ÏÎÐÀÆÅÍÈÅ ÝËÅÊÒÐÈ×ÅÑÊÈÌ ÒÎÊ ÎÌ ÎÏÀÑÍÎ ÄËß ÆÈÇÍÈ !
S Óñòàíîâèòå è çàçåìëèòå ñâàðî÷ íûé àïïàðàò â ñîîòâåòñòâèè ñ ïðèìåíÿåìûìè ñòàíäàðòàìè.
S Íå êàñàéòåñü îã îëåííûõ ýëåêòðè÷åñêèõ ÷àñòåé èëè ýëåêòðîäîâ ãîëûìè ðóêàìè, ìîêðûìè ïåð÷àòêàìè
èëèìîêðîéîäåæäîé.
S Èçîëèðóéòå ñåáÿ îò çåìëè è çàãîòîâêè.
S Îáåñïå÷üòå áåçîïàñíîñò ü íà ñâîåì ðàáî÷åì ìåñò å.
ÑÂÀÐÎ×ÍÛÅ ÄÛÌÛ È ÀÝÐÎÇÎËÈ - ìîãóò áûòü îïàñíû äëÿ çäîðîâüÿ.
S Ñòàðàéòåñü, ÷òîáû âàøà ãîëîâà íàõîäèëàñü âíå çîíû äûìà..
S Èñïîëüçóéòå âåíòèëÿöèþ è äûìîîòñîñû äëÿ óäàëåíèÿ äûìîâ è àýðîçîëåé èç çîíû äûõàíèÿ è
îêðóæàþùåãî ïðîñòðàíñòâà
ÈÇËÓ×ÅÍÈÅ ÄÓÃÈ - ìîæåò íàíåñòè âðåä ãëàçàì è êîæå.
S Çàùèùàéòå âàøè ãëàçà è êîæó. Èñïîëüçóéòå ìàñêó ñ ïðàâèëüíî ïîäîáðàííûì çàùèòíûìñòåêëîì è
ñïåöîäåæäó
S Çàùèùàéò å îêðóæàþùèõ ïîñðåäñòâîì ñòåíîê è çàíàâåñîê.
ÏÎÆÀÐÎÎÏÀÑÍÎÑÒÜ
S Èñêðû ïðè ñâàðêå ìîãóò ñòàò ü ïðè÷èíîé ïîæàðà. Îáåñïå÷üòå îòñóòñòâèå ïîæàðîîïàñíûõ ìàòåðèàëîâ
â áëèçëåæàùåé çîíå.
ØÓÌ - Ïîâûøåííûé øóì ìîæåò ïîâðåäèòü ñëóõ
S Çàùèòèòå ñâîè óøè ñ ïîìîùüþ íàóøíèêîâ èëè áåðóøåé.
S Ïðåäóïðåäèòå î ðèñêå îêðóæàþùèõ.
ÑÁÎÉ Â ÐÀÁÎÒÅ - Ïðè ñáîÿõ â ðàáîòå îáðàòèòåñü çà ïîìîùüþ ê ñïåöèàëèñòó.
2 ÂÂÅÄÅÍÈÅ
LHF 250/400/630/800 ÿâëÿþòñÿ ñâàðî÷íûìè âûïðÿìèòåëÿìè ñ òèðèñòîðíûì
óïðàâëåíèåì, ïðåäíàçíà÷åííûìè äëÿ ðó÷íîé ñâàðêè ïîêðûòûìè ýëåêòðîäàìè
ÌÀ), ñâàðêè íåïëàâÿùèìñÿ ýëåêòðîäîì â çàùèòíûõ ãàçàõ (ÒIG) è äëÿ
âîçäóøíî-äóãîâîé ñòðîæêè.
Âûïðÿìèòåëè ìîã óò ðàáîòàòü ñî ñëåäóþùèìè ïóëüòàìè äèñòàíöèîííîãî
óïðàâëåíèÿ: PHA 1, PHA 2, PHA 5, PHB 1, PHB 2, è PHC 2.
Äëÿ ñâàðêèìÒÈà íåîáõîäèìî äîïîëíèòåëüíîå óñòðîéñòâî ñ âûñîêî÷àñòîòíûì
ïîäæèãîì äóãè
LHF 400/630 ñ èçìåðèòåëüíûìè ïðèáîðàìè è âåíòèëÿòîðîì ñ òàéìåðîì.
Ýòè ñâàðî÷íûå âûïðÿìèòå ëè èìåþò íà ïåðåäíåé ïàíåëè âîëüòìåòð è
àìïåðìåòð, ïîçâîëÿþùèå çàìåðÿòü âåëè÷èíû íàïðÿæåíèÿ è òîêà.
Äëÿ òîãî, ÷òîáû óìåíüøèòü êîëè÷åñòâî çàíîñèìîé â âûïðÿìèòåëü ïûëè,
÷àñòîòà âðàùåíèÿ âåíòèëÿòîðà â ðåæèìå õîëîñòîãî õîäà ñíèæàåòñÿ äî 300
îá/ìèí. Ïðè âîçðàñòàíèè ñâàðî÷íîãî òîêà âûøå 30 À âåíòèëÿòîð íà÷èíàåò
ðàáîòàòü â ðàáî÷åì ðåæèìå - 1350 îá/ìèí. Ðåëå âðåìåíè ïîääåðæèâàåò
RU
bh10d2r -- 5 --
âûñîêóþ ñêîðîñòü âðàùåíèÿ â òå÷åíèå 6,5 ìèí ïîñëå ïðåêðàùåíèÿ ñâàðêè
ä ëÿ ïîëíîãî îõëàæäåíèÿ âûïðÿìèòåëÿ.
3 ÒÅÕÍÈ×ÅÑÊÈÅ ÄÀÍÍÛÅ
LHF 250 LHF 400 LHF 630 LHF 800
Ìàêñ. íàãðóçêà
ïðè ÏÂ 35 % 250 A/30 V 400 A/36 V 630 A/44 V 800 A/44 V
ïðè ÏÂ 60 % 200 A/28 V 315 A /33 V 500 A/40 V 630 A/44 V
ïðè ÏÂ 100 % 160A/26V 250 A/30 V 400 A/36 V 500 A/40 V
Ðåæèìû ðàáîòû 8A/20V-250A/30(
33)V
8A/20V-400A/36
V
8A/20V-630A/44(
49)V
8A/20V-800A/44(
50)V
Íàïðÿæåíèå
õîëîñòîãî õîäà
78-84 V 80-87 V 65-72 V 65-72 V
Ïîòðåáëÿåìàÿìîùí
îñòü ïðè 400 V
300 W 340 W 615 W 640 W
Êîåô. ìîùíîñòè
(ìàêñ. òîê)
0,88 0,90 0,87 0,82
ÊÏÄ (ìàêñ. òîê) 68 % 74 % 77 % 78 %
Ê ëàññ çàùèòû IP 23 IP 23 IP 23 IP 23
Êëàññ ïðèìåíåíèÿ
Ìàññà 160 êã 195 êã 260 êã 295 êã
Ãàáàðèòû:äxøxâ 1310 / 765 / 705 1310 / 765 / 705 1310 / 765 / 705 1310 / 765 / 705
Ðàáî÷èé öèêë
Ðàáî÷èé öèêë ïðåäñòàâëÿåò ñîáîé äîëþ %%) äåñÿòèìèíó òíîãî èíòåðâàëà, â òå÷åíèå
êîòîðîé ìîæíî ïðîèçâîäèòü ñâàðêó ïðè îïðåäåëåííîé íàãðóçêå á åç ïåðåãðóçêè.
Êëàññ êîæóõà
Íîðìû IP óêàçûâàþò êëàññ êîæóõà, ò.å., ñòåïåíü çàùèòû îò ïðîíèêíîâåíèÿ ò âåðäûõ
îáúåêòîâ è âîäû. Îáîðóäîâàíèå ñ ìàðêèðîâêîé IP 23 ïðåäíàçíà÷åíî äëÿ íàðóæíîé è
âíóòðåííåé óñòàíîâêè.
Ê ëàññ çîíû óñòàíîâêè
Ýòîò ñèìâîë îçíà÷àåò, ÷òî èñòî÷íèê ïèòàíèÿ ïðåäíàçíà÷åí äëÿ èñïîëüçîâàíèÿ â çîíàõ
ñ ïîâûøåííîé îïàñíîñòüþ ïîðàæåíèÿ ýëåêòðîòîêîì.
RU
bh10d2r -- 6 --
ÑÒÀÍÎÂÊÀ
Ââîä â ýêñïëóàòàöèþ äîëæåí ïðîèçâîäèòüñÿ êâàëèôèöèðîâàííûì
ñïåöèàëèñòîì.
ÂÍÈÌÀÍÈÅ!
Íàñòîÿùåå èçäåëèå ïðåäíàçíà÷åíî äëÿ ïðîìûøëåííîãî èñïîëüçîâàíèÿ. Ïðè
èñïîëüçîâàíèè â áûòîâûõ óñëîâèÿõ îíî ìîæåò ñîçäàâàòü ðàäèî÷àñòîòíûå ïîìåõè.
Ïîëüçîâàòåëü îòâå÷àåò çà ïðèíÿòèå ñîîò â åòñòâóþùèõ ìåð ïðåäîñòîðîæíîñòè.
S Óñòàíîâêà äîëæíà ïðîèçâîäèòüñÿ êâàëèôèöèðîâàííûì ýëåêòðèêîì.
S Ïåðåä ïîäêëþ÷åíèåì ê ýëåêòðîñåòè óáåäèòåñü, ÷òî äàííîå îáîðóäîâàíèÿ
ðàññ÷èòàíî íà íàïðÿæåíèå ïèòàþùåé ñåòè.
S Âûáåðèòå ñå÷åíèÿ êàáåëåé è âåëè÷èíû ïðåäîõðàíèòåëåé â ñîîòâåòñòâèå ñ
ðàçäåëîì ”Ïîäêëþ÷åíèå ê ýëåêòðîñåòè”.
S Ïîäñîåäèíèòå êàáåëü ïèòàíèÿ ê âûïðÿìèòåëþ â ñîîòâåòñòâèè ñ ìåñòíûìè
òðåáîâàíèÿ è óñòàíîâèòå â ùèòêå ñîîòâåòñòâóþùèå ïðåäîõðàíèòåëè.
S Óñòàíîâèòå àïïàðàò â ïîä õîäÿùåì ìåñòå è óáåäèòåñü, ÷òî äîñò óï âîçäóõà
ä ëÿ îõëàæäåíèÿ àïïàðàòà íå ïåðåêðûò.
4.1 Ïîäêëþ÷åíèå ê ýëåêòðîñåòè
LHF 250 LHF 400 LHF 630 LHF 800
×àñòîòà 50 Hz 50 Hz 50 Hz 50 Hz
Íàïðÿæåíèå 230/400/
415/ 500 V
230/400/
415/ 500 V
230/400/
415/ 500 V
230/400/
415/ 500V
Òîê ïðè
ÏÂ 100%
20/11/11/9A 34/19/19/16 A 65/38/38/30 A 86/49/49/40 A
ÏÂ 60% 25/14/14/11 A 42/24/24/20 A 81/47/47/38 A 10 7/62/60/50A
ÏÂ 35% 31/ 18/18/14 A 53/31/31/25 A 102/59/59/47A 136/79/79/63A
Ïðåäîõðàíèòåëü 25/16/16/16 A 63/25/25/20 A 80/50/50/35 A 100/63/63/50A
ÑåPåíèå êàáåëÿ
(4õìì2)
4/1,5/1,5/1,5 10/4/4/2,5 25/10/10/6 35/10/10/10
LHF 250 LHF 400 LHF 630 LHF 800
×àñòîòà 60 Hz 60 Hz 60 Hz 60 Hz
Íàïðÿæåíèå 230/440/550V 230/440/550V 230/440/550V 230/440/550V
Òîê ïðè
ÏÂ 100%
20/11/9 A 34/19/16 A 65/38/30 A 86/49/40 A
ÏÂ 60% 25/14/11 A 42/24/20 A 81/47/38 A 107/62/50 A
ÏÂ 35% 31/ 18/14 A 53/31/25 A 102/59/47 A 136/79/63 A
Ïðåäîõðàíèòåëü 25/16/16 A 63/25/20 A 80/50/35 A 100/63/50 A
Ñå÷åíèå êàáåëÿ
(4õìì2)
4/1,5/1,5 10/4/2,5 25/10/6 35/10/10
Ñå÷åíèå êàáåëåé ñîîòâ åòñòâóåò jâåäñêèì íîðìàì.
RU
bh10d00
1
bh10d2r -- 7 --
ÊÑÏËÓÀÒÀÖÈß
S Óñòàíîâèòå âûêëþ÷àòåëü (1) â ïîëîæåíèå ”I”. Çàãîðèò ñÿ áåëàÿ èíäèêàòîðíàÿ
ëàìïà (2) è íà÷íåò âðàùàòüñÿ âåíòèëÿòîð îõëàæäåíèÿ.
S Ïåðåêëþ÷àòåëåì (3) óñòàíîâèòå ñïîñîá ñâàðêè.
S Óñòàíîâèòå âåëè÷èíó ñâàðî÷íîãî òîêà ðåãóëÿòîðîì (7) íà ëèöåâîé ïàíåëè è
óñòàíîâèò å ïåðåêëþ÷àòåëü (8) â ïîëîæåíèå ïî íàïðàâëåíèþ ê ðàçúåìó.
.
S Ïîäñîåäèíèòå ñâàðî÷íûé è îáðà ò íûé êàáåëè ê êîíòàêò àì “+” è -” íà ïåðåäíåé
ïàíåëè âûïðÿìèòåëÿ. Ïîäñîåäèíèòå îáðàòíûé êàáåëü ê èçäåëèþ
S Âûïðÿìèòåëü ãîòîâ ê ðàáîòå .
5.1 Óïðàâëåíèÿ è ðàçú¸ìû
1. Âêë/Âûêë
2. Áåëàÿ ëàìïà (âûïðÿìèòåëü âêëþ÷åí)
3. Ïåðåêëþ÷åòåëü ñïîñîáà ñâàðêè
4. Âîçäóøíî-äóãîâàÿ ñòðîæêà
5. MMA
6. ÒIG
7. Óñòàíîâêà ñâàðî÷íîãî òîêà
8. Âûêëþ÷àò åëü äèñò. óïðàâëåíèÿ
9. Ðàçúåì äèñòàíöèîííîãî óïðàâëåíèÿ
10. Æ åëòàÿ ëàìïà (îòêëþ÷åíèå ïðè ïåðåãðåâå)
Æ åëòàÿ èíäèêàòîðíàÿ ëàìïà çàãîðàåòñÿ ïðè ñðàáàòûâàíèè òåðìîçàùèòû.
Ïîñëå òîãî, êàê âûïðÿìèòåëü îõëàäèòüñÿ îí àâòîìàòè÷åñêè âêëþ÷èòñÿ
6 ÎÁÑËÓÆÈÂÀÍÈÅ
Çàùèòíûå ùèòû äîëæ åí ñíèìàòü ñ öåëüþ: ïîäêëþ÷åíèÿ, îáñëóæèâàíèÿ è
ðåìîíòà ñâàðî÷íîãî îáîðóäîâàíèÿ òîëüêî ñïåöèàëèñò (èìåþùèé äîïóñê).
Ïðèìå÷àíèå:
à àðàíòìèéíûå îáÿçàòåëüñòâà ïîñòàâùèêà òåðÿþò ñèëó, åñëè ïîêóïàòåëú
ñàìîñòîÿòåëúíî ïûòàåòñÿ ïð îèçâåñòè êàêèå-ëèáî ðàáîòû ïî óñòðàíåíèþ
íåèñïðàâíîñòåé èçäåëèÿ â òå÷åíèå ãàðàíòèéíîãî ñðîêà.
RU
bh10d2r -- 8 --
×èñòêà
Ðåã óëÿðíî ïðîâåðÿéòå, ÷òîáû èñòî÷íèê ïèòàíèÿ íå áûë çàãðÿçíåí.
Íàñêîëüêî ÷àñòî è êàê äîëæíà îñóùåñòâëÿòüñÿ ÷èñòêà çàâèñèò îò: ïðîöåññà
ñâàðêè, ïðîäîëæèòåëüíîñòè ñâàðî÷íîé äóãè, ðàçìåùåíèÿ è îêðóæàþùåé
ñðåäû. Îáû÷íî äîñòàòî÷íî ïðîäóòü èñòî÷íèê ïèòàíèÿ ñæàòûì âîçäóõîì
(ïîíèæåííîå äàâëåíèå) îäèí ðàç â ãîä.
Ïðè ñèëüíîì çàãðÿçíåíèè ðåêîìåíäóåòñÿ ïðîäóâàíèå è ÷èñòêà ïûëåñîñîì.
S Îòêëþ÷èòå ñâàðî÷íîå îáîðóäîâàíèå îò èñòî÷íèêà ïèòàíèÿ.
S Äîñò àíüòå ê îíòàêòíûé øòåêåð èç ðàçååìà. Çàìêíèòå ðàçååì,, ÷òîáû íå
ïðîèçîøëî íåïðîèçâîëüíîãî âêëþ÷åíèÿ.
Ïðè ñò àöèîíàðíîé óñòàíîâêå, ïåðåâåäèòå ïðåäîõðàíèòåëüíûé
âûê ëþ÷àòåëü â âûêëþ÷åííîå ïîëîæåíèå. Çàìêíèòå âûêëþ÷àòåëü íà
çàìîê.
S Ñíèìèòå çàùèòíûå ùèòû íà èñòî÷íèêå ïèòàíèÿ, ÷òîáû óëó÷øèòü äîñò óï.
Ïîñëå ÷èñòêè óñòàíîâèòå âñå çàùèòíûå ùèòû íà ìåñòî ïåðåä òåì, êàê áóäåò
ïîäê ëþ÷åíî ïèòàíèå.
7 ÇÀÊÀÇ ÇÀÏÀÑÍÛÕ ×ÀÑÒÅÉ
Çàïàñíûå ÷àñòè ìîæíî çàêàçòú ó áëèæàéøåãî ê Âàì ESAB, (ñì. ïåðå÷åíú íà
ïîñëåäíåé ñòðàíèöå äàííîé áðîøþðû). Ïðè çàêàçå ñëåäóå ò óêàçûâàòú òèï
èçäåäèÿ, çàâîäñêîé íîìåð, íàçâàíèå è íîìåð çàïàñíîé ÷àñòè ñîãëàñíî
çàïàñíûõ ÷àñòåé. Òàêèì îáðàçîì óïðîùàåò ñ ÿ ïðîöåññ îòïðàâêè è
èñêëþ÷àþòñÿ îøèáêè ïðè äîñòàâêå.
RU
ENGLISH
-- 9 --
TOCe
1SAFETY 10...........................................................
2 INTRODUCTION 11...................................................
3 TECHNICAL DATA 11.................................................
4 INSTALLATION 12....................................................
4.1 Connecting to mains 12.......................................................
5 OPERATION 13.......................................................
5.1 Controls and connections 13...................................................
6 MAINTENANCE 14....................................................
7 ORDERING OF SPARE PARTS 14......................................
ASSEMBLY INSTRUCTIONS 15...........................................
DIAGRAM 16............................................................
SPARE PARTS LIST 21...................................................
-- 1 0 --
bh10d13e
1DIRECTIVE
DECLARATION OF CONFORMITY
ESAB Welding Equipment AB, S--695 81 Laxå, Sweden, gives its unreserved guarantee that welding
power source LHF 250 / 400 / 630 / 800 from serial number 550 complies with standard IEC/EN
60974--1, in accordance with the requirements of directive (73/23/EEC) and addendum (93/68/EEC)
and with standard EN 50199 in accordance with the requirements of directive (89/336/EEC) and add-
endum (93/68/EEC).
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --------
Anders Birgersson
Managing Director
ESAB Welding Equipment AB
695 81 LA
SWEDEN Tel: + 46 584 81000 Fax: + 46 584 411924
Laxå 1995--04--10
2SAFETY
WARNING
READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE INSTALLING OR OPERATING.
ARC WELDING AND CUTTING CAN BE INJURIOUS TO YOURSELF AND OTHERS. TAKE PRECAU -
TIONS WHEN WELDING. ASK FOR YOUR EMPLOYER’S SAFETY PRACTICES WHICH SHOULD BE
BASED ON MANUFACTURERS’ HAZARD DATA.
ELECTRIC SHOCK -- Can kill
S Install and earth the welding unit in accordance with applicable standards.
S Do not touch live electrical parts or electrodes with bare skin, wet gloves or wet clothing.
S Insulate yourself from earth and the workpiece.
S Ensure your working stance is safe.
FUMES AND GASES -- Can be dangerous to health
S Keep your head out of the fumes.
S Use ventilation, extraction at the arc, or both, to take fumes and gases away from your breathing zone
and the general area.
ARC RAYS -- Can injure eyes and burn skin.
S Protect y our eyes and body. Use the correct welding screen and filter lens and wear protective
clothing.
S Protect bystanders with s uitable screens or curtains.
FIRE HAZARD
S Sparks (spatter) can cause fire. Make sure therefore that there are no inflammable materials nearby.
NOISE -- Excessive noise can damage hearing
S Protect y our ears. Use earmuffs or other hearing protection.
S Warn bystanders of the risk.
MALFUNCTION -- Call for expert assistance in the event of malfunction.
PROTECT YOURSELF AND OTHERS!
GB
-- 1 1 --
bh10d13e
3 INTRODUCTION
LHF 250/400/630/800 are thyristor controlled welding rectifiers designed for welding
with coated electrodes, TIG welding and arc air gouging.
The welding rectifiers can be used with the following r emote control devices:
PHA 1, PHA 2, PHA 5, PHB 1, PHB 2, och PHC 2.
An auxiliary control unit is required for T IG welding with high frequency ar c ignition.
LHF 400/630, versions with meters and timed co o lin g fan.
These welding rectifiers are equipped with a volmeter, ammeter and a circuit that
reduces the idle speed of the cooling fan.
The meters allow current and voltage settings to be read from the front of the
rectifier.
To minimise the amount of dust and dirt that is drawn into the rectifier the fan runs at
a reduced idle speed of 300 rpm. When welding with currents greater than 30 A the
fan speed increases to its working speed of around 1350 rpm. A timer relay
maintains the higher speed setting for 6 1/2 minutes after welding has stopped to
ensure adequate cooling of the rectifier.
4 TECHNICAL DATA
LHF 250 LHF 400 LHF 630 LHF 800
Maximum load
35 % duty cycle 250 A/30 V 400 A/36 V 630 A/44 V 800 A/44 V
60 % duty cycle 200 A/28 V 315 A/33 V 500 A/40 V 630 A/44 V
100 % duty cycle 160 A/26 V 250 A/30 V 400 A/36 V 500 A/40 V
Setting range 8A/20V--250A/30
(33)V
8A/20V--400A/36
V
8A/20V--630A/44
(49)V
8A/20V--800A/44
(50)V
Open circuit volt. 78--84 V 80--87 V 65--72 V 65--72 V
Open circuit output
at 400 V
300 W 340 W 615 W 640 W
Power factor
(max current)
0,88 0,90 0,87 0,82
Efficiency
(max current)
68 % 74 % 77 % 78 %
Enclosure class IP 23 IP 23 IP 23 IP 23
Application class
Weight 160 kg 195 kg 260 kg 295 kg
Dimens. lxwxh 1310/765/705 1310/765/705 1310/765/705 1310/765/705
Duty cycle
The duty cycle refers to the time as a percentage of a ten--minute period that you can weld at a cer-
tain load without overloading.
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked IP23 is designed for indoor and outdoor use.
Application class
The symbol indicates that the power source is designed for use in areas with increased
electrical hazard.
GB
-- 1 2 --
bh10d13e
5 I NSTALLATION
The installatio n must be executed by a professional.
WARNING!
This product is intended for industrial use. In a domestic environment this product may cause radio
interference. It is the user’s responsibility to take adequate precautions.
S Installation must be carried out by a qualified electrician.
S Check that the welding rectifier is configured for the available mains supply
before connecting it to the mains.
S See Connecting to mains for cable rating and fuse rating.
S Connect the mains cable to the rectifier according to the relevant regulations and
install a suitable fuse in the main fuse box.
S Make sure the welding rectifier is not covered or positioned so that cooling is
obstructed.
5.1 Connecting to mains
LHF 250 LHF 400 LHF 630 LHF 800
Frequency 50 Hz 50 Hz 50 Hz 50 Hz
Voltage 400/415/500 V 400/415/500 V 400/415/500 V 400/415/500 V
Current at
100% duty cycle
11/11/9A 19/19/16 A 38/38/30 A 49/49/40 A
60% duty cycle 14/14/11 A 24/24/20 A 47/47/38 A 62/60/50A
35% duty cycle 18/18/14 A 31/31/25 A 59/59/47A 79/79/63A
Fuse,slow 16/16/16 A 25/25/20 A 50/50/35 A 63/63/50A
Cable area (4xmm2) 1,5/1,5/1,5 4/4/2,5 10/10/6 10/10/10
LHF 250 LHF 400 LHF 630 LHF 800
Frequency 60 Hz 60 Hz 60 Hz 60 Hz
Voltage 440/550V 440/550V 440/550V 440/550V
Current at
100% duty cycle
11/9 A 19/16 A 38/30 A 49/40 A
60% duty cycle 14/11 A 24/20 A 47/38 A 62/50 A
35% duty cycle 18/14 A 31/25 A 59/47 A 79/63 A
Fuse,slow 16/16 A 25/20 A 50/35 A 63/50 A
Cable area (4xmm2) 1,5/1,5 4/2,5 10/6 10/10
Cable areas comply with Swedish regulations.
GB
-- 1 3 --
bh10d13e
6OPERATION
S Set switch (1) to position ”I”. The white lamp (2) will light and the fan will start.
S Select the welding method using the toggle switch (3).
S Adjust the welding current using the knob (7) on the front, and set the toggle
switch (8) to the position nearest the socket.
S Select suitable earth and return cables and connect them to the terminals
marked + and -- on the front of the rectifier. Connect the return cable to the work
piece.
S The rectifier is now ready for welding.
6.1 Controls and connections
1. On/Off
2. White lamp (power on)
3. Method selector switch
4. Arc air gouging
5. MMA
6. TIG
7. Current setting
8. Remote switch
9. Remote socket
10. Yellow lamp (thermal cut--out)
The yellow lamp comes on when the thermal cut--out trips.
When the r ectifier has cooled down the thermal cut -- out is automatically reset.
GB
bh10d001
-- 1 4 --
bh10d13e
7 MAINTENANCE
Note!
All guarantee undertakings from the supplier cease to apply if the customer himself
attempts any work in the product during the guarantee period in order to rectify any
faults.
Only those persons who have appropriate electrical knowledge (authorised
personnel) may remove the safety plates to connect or carry out service,
maintenance or repair work on welding equipment.
Cleaning
Check regularly that the power source is free from dirt.
How often, and to what extent, cleaning should be carried out depends on the
welding process, arc time, disposition and the surrounding envir onment. It will
normally suffice to blow the power source clean using compressed air (reduced
pressure) once a year.
If the power source is very dirty, brushing and vacuuming are recommended.
S Disconnect the welding power source from the mains current supply.
S Remove the adapter from the socket. Lock the socket to prevent unauthorised
connection.
At fixed installations, the safety switch should be set to the off position. Lock
the switch.
S Remove the power source’s safety plates for best access.
After cleaning, all safety plates must be mounted before you connect the power
source to the mains supply.
8 ORDERING OF SPARE PARTS
LHF 250, LHF 400, LHF 630, LHF 800 is designed and tested in accordance with the in-
ternational an European standards IEC/EN 60 974--1 and EN 60 974--1.
It is the obligation of the service unit which has carried out the service or repair work
to make sure that the product still conforms to the said standard.
Spare parts are ordered through your nearest ESAB representative, see back cover.
When ordering spare parts, please state machine type and number as well as desig-
nation and spare part number as shown in the spare parts list on page 21.
This will simplify shipme nt and ensure you get the right part.
GB
Assembly instructions Èíñòðóêöèè ïî ñáîðêå
-- 1 5 --
bh10a12a
bh10d002
Diagram Ñõåìà
-- 1 6 --
bh10e12a
Prim. 250/400
-- 1 7 --
bh10e12a
Sek. 250/400
-- 1 8 --
bh10e12a
Prim. 630/800
-- 1 9 --
bh10e12a
Sek. 630/800
-- 2 0 --
sida
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34

ESAB LHF 630 Manuale utente

Categoria
Sistema di saldatura
Tipo
Manuale utente
Questo manuale è adatto anche per