ProLights VERSAPAR Manuale utente

Categoria
Stroboscopi
Tipo
Manuale utente
USER MANUAL
MANUALE UTENTE
VERSAPAR
EN - IT
PARLED ZOOM
All rights reserved by Music & Lights S.r.l. No part of this instruction manual may be
reproduced in any form or by any means for any commercial use.
In order to improve the quality of products, Music&Lights S.r.l. reserves the right to modify the
characteristics stated in this instruction manual at any time and without prior notice.
All revisions and updates are available in the ‘manuals section on site www.musiclights.it
REV. 03-02/19
1
VERSAPAR
Packing content
VERSAPAR
Mount bracket (2 pc.)
Power cable
User manual
TABLE OF CONTENTS
Safety
General instructions
Warnings and installation precautions
1 Introduction
1. 1 Description
1. 2 Technical specications
1. 3 Operating elements and connections
2 Installation
2. 1 Mounting
3 Functions and settings
3. 1 Operation
3. 2 Basic
3. 3 Menu structure
3. 4 Auto show
3. 5 Static mode
3. 6 Manual mode
3. 7 Master/Slave mode
3. 8 Linking
3. 9 DMX mode
3. 10 DMX addressing
3. 11 Connection of the DMX line
3. 12 Construction of the DMX termination
3. 13 DMX control
3. 14 Dimmer
3. 15 Back light
3. 16 Fixture information
3. 17 LED frequency
3. 18 Temperature
3. 19 Fan mode
3. 20 White balance
4 Maintenance
4. 1 Maintenance and cleaning the unit
4. 2 Fuse replacement
4. 3 Trouble shooting
2
2
3
3
5
6
7
7
8
9
9
10
10
10
10
10
12
12
13
14
14
14
14
14
15
15
16
16
16
VERSAPAR
2
SAFETY
General instruction
The products referred to in this manual conform to the European Community Directives and are there-
fore marked with .
The unit is supplied with hazardous network voltage (230V~). Leave servicing to skilled personnel only.
Never make any modications on the unit not described in this instruction manual, otherwise you will
risk an electric shock.
Connection must be made to a power supply system tted with ecient earthing (Class I appliance ac-
cording to standard EN 60598-1). It is, moreover, recommended to protect the supply lines of the units
from indirect contact and/or shorting to earth by using appropriately sized residual current devices.
The connection to the main network of electric distribution must be carried out by a qualied electrical
installer. Check that the main frequency and voltage correspond to those for which the unit is designed
as given on the electrical data label.
This unit is not for home use, only professional applications.
Never use the xture under the following conditions:
- in places subject to vibrations or bumps;
- in places with a temperature of over 40 °C.
Make certain that no inammable liquids, water or metal objects enter the xture.
Do not dismantle or modify the xture.
All work must always be carried out by qualied technical personnel. Contact the nearest sales point for
an inspection or contact the manufacturer directly.
If the unit is to be put out of operation denitively, take it to a local recycling
plant for a disposal which is not harmful to the environment.
Warnings and installation precautions
If this device will be operated in any way dierent to the one described in this manual, it may suer
damage and the guarantee becomes void. Furthermore, any other operation may lead to dangers like
short circuit, burns, electric shock, etc.
Before starting any maintenance work or cleaning the projector, cut o power from the main supply.
Always additionally secure the projector with the safety rope. When carrying out any work, always com-
ply scrupulously with all the regulations (particularly regarding safety) currently in force in the country
in which the xture’s being used.
Install the xture in a well ventilated place.
Keep any inammable material at a safe distance from the xture.
Shields, lenses or ultraviolet screens shall be changed if they have become damaged to such an extent
that their eectiveness is impaired.
The lamp (LED) shall be changed if it has become damaged or thermally deformed.
Never look directly at the light beam. Please note that fast changes in lighting, e. g. ashing light, may
trigger epileptic seizures in photosensitive persons or persons with epilepsy.
Do not touch the product’s housing when operating because it may be very hot.
WARNING! Before carrying out any operations with the unit, carefully read this instruction
manual and keep it with cure for future reference. It contains important information about
the installation, usage and maintenance of the unit.
3
VERSAPAR
- 1 - INTRODUCTION
1.1 DESCRIPTION
VERSAPAR is a new generation ParLED zoom, designed for rental-company, with a multi-purpose con-
cept suitable for both stage and architectural lighting, in environments of large and medium size.The
peculiar single-lens optical system with plano-convex endings enhances the 12x10W RGB/FullColor LED
source through a reecting technique implying colors to be pre-mixed in optical channels. A technical
solution allowing a chromatic naturalism that is simply out of reach for LED-powered projectors of previ-
ous generations. VERSAPAR also features a 10°-60° unrivaled zoom to have fantastic beam eects with
great denition or to angle wide for high-diusion wash looks. Excellent eciency and perfect chromatic
uniformity are maintained throughout the zoom range. VERSAPAR is a project developed for professional
venues by oering a new dimmer technology with super-linear and anti-ickering ramp for any camera,
with frequency adjustment from the user interface. The absolute noiseless VERSAPAR operation makes
it suitable even in noise sensitive environments or in applications with a large quantity of projectors.
1.2 TECHNICAL SPECIFICATIONS
LIGHT SOURCE
Source: 12x10W RGBW LEDs
Luminous ux: (10°) 1223 - (60°) 1423lm
Lux: (10°) 6071lux @3m full
Lux: (60°) 654,8lux @3m full
Source life expectancy: >50.000 h
OPTICS
Zoom: 10-60° motorised linear zoom
Lens type: plano-convex lens path
COLOUR SYSTEM
Colour mixing: RGBW/FC
White presets: 3200~10000K
Colour wheel: virtual colour wheel with presets
Macros: built-in white presets
DYNAMIC EFFECTS
Static colour mode: selection of static colour
Manual colour mode: manual adjustment of colour
Auto mode: built-in programs with execution speed adjustment
BODY
Body: sturdy die-cast aluminium body conceived for long-time durability
Body colour: black
CONTROL
Protocols: DMX512
DMX channels: 5/7/10channel
Display: black OLED high resolution display
Firmware upgrade: yes, via USB-DMX interface (UPBOX1) not included
Master/Slave: for synchronized operation of more units linked in a chain
VERSAPAR
4
350
261262
ELECTRONICS
Dimmer: linear 0~100% electronic dimmer
Dimmer curves: 4 dierent dimming curves available
Strobe / shutter: 1-28 Hz, electronic
Operating temperature: -10° ~ +45°
Flicker: icker free operation
Selectable PWM: 600~25K Hz
ELECTRICAL
Power supply: 100-240V – 50/60Hz
Power consumption (at 230V): 121W
Power consumption (at 120V): 120W
Output (at 230V): 12 units on a single power line
PHYSICAL
Cooling: forced air with low noise fan
Sospension and xing: double hanging bracket suitable for safe hanging and for oor positioning
Signal connection: XLR 3p+5p IN/OUT connectors
Power connection: Neutrik powerCON IN/OUT connectors
IP rating: 30
Dimensions (WxHxD): 262x350x261mm
Weight: 5.5kg
Fig.1
Technical drawing
5
VERSAPAR
1.3 OPERATING ELEMENTS AND CONNECTIONS
1. SCREW for the mounting bracket
2. MOUNTING BRACKET
3. DMX IN (3-pole XLR):
1 = ground, 2 = DMX -, 3 = DMX +
4. DMX OUT (3-pole XLR):
1= ground, 2 = DMX -, 3 = DMX +
5. CONTROL PANEL with display and 4 button
used to access the control panel functions
and manage them
6. DMX IN (5-pole XLR):
1 = ground, 2 = DMX-, 3 = DMX+, 4 N/C, 5 N/C
7. DMX OUT (5-pole XLR):
Rear panel Fig.2
1 = ground, 2 = DMX-, 3 = DMX+, 4 N/C, 5 N/C
8. POWER IN (PowerCON IN): for connection to a
socket (100-240V~/50-60Hz) via the supplied
mains cable
9. MAIN FUSE HOLDER: replace a burnt-out fuse
by one of the same type only (T2A/250V)
10. GND POINT grounding the xture to the earth
11. SAFETY RING to attach safety cable
12. POWER OUT: connect to supply power to the
next unit
43
5
6
7
9 10 11 12
8
1
2
VERSAPAR
6
- 2 - INSTALLATION
2.1 MOUNTING
VERSAPAR may be set up on a solid and even surface. The unit can also be mounted upside down to a cross
arm. For xing, stable mounting clips are required. The mounting place must be of sucient stability and
be able to support a weight of 10 times of the unit’s weight.
When carrying out any installation, always comply scrupulously with all the regulations (particularly re-
garding safety) currently in force in the country in which the xture’s being used.
Install the projector at a suitable location by means of the mounting bracket (1).
Always additionally secure the projector with the safety rope from falling down. For this purpose, fas-
ten the safety rope at a suitable position so that the maximum fall of the projector will be 20 cm.
Adjust the projector and use the screw to slightly release or tighten the locking mechanism of the
bracket if is necessary (2).
Fig.3
1
2
7
VERSAPAR
- 3 - FUNCTIONS AND SETTINGS
3.1 OPERATION
Connect the supplied main cable to a socket (100-240V~/50-60Hz). Then the unit is ready for operation
and can be operated via a DMX controller or it independently performs its show program in succession.
To switch o, disconnect the mains plug from the socket. For a more convenient operation it is recom-
mended to connect the unit to a socket which can be switched on and o via a light switch.
3.2 BASIC
Access control panel functions using the four panel buttons located directly underneath the black OLED
display (g.4).
Fig.4 - Functions of the buttons
MENU UP DOWN ENTER
Used to access the menu or
to return a previous menu
option
Navigates downwards through
the menu list and increases
the numeric value when in a
function
Navigates upwards through
the menu list and decreases
the numeric value when in
a function
Used to select and store the
current menu or conrm the
current function value or
option within a menu
MENU UP DOWN ENTER
VERSAPAR
8
3.3 MENU STRUCTURE
MENU
1 Auto Show
ð
Auto 1
ð
Speed (0-100)
Auto 2
ð
Speed (0-100)
Auto 3
ð
Speed (0-100)
Auto 4
ð
Speed (0-100)
2 Static
ð
Fixed Color
ð
R
ð
G
ð
B
ð
W
ð
GB
ð
RB
ð
RG
ð
RGB
ð
RW
ð
GW
ð
BW
ð
RGW
ð
RBW
ð
GBW
ð
RGBW
Manual Color
ð
R = 255
ð
G = 255
ð
B = 255
ð
W = 255
3 Zoom
ð
Zoom (0-255)
4 Dimmer Mode
ð
O
Dimmer 1
Dimmer 2
Dimmer 3
5 Back Light
ð
On
10 S
20 S
30 S
9
VERSAPAR
3.4 AUTO SHOW
If no DMX control signal is present at the DMX INPUT, the unit independently runs through its show pro-
gramme provided that the blackout mode is switched o:
Press the button MENU so many times until the display shows Auto Show, then press the button ENTER.
Press the button UP/DOWN to switch between the show Auto 1 - Auto 4. The unit will operate in show
mode.
Using the button UP/DOWN to select the desired run speed slow-fast 0-100.
Press the button ENTER to save the setting.
IMPORTANT: Programs Auto 1 - 4 are fully pre-programmed and will not be altered by changes. Instead,
3.5 STATIC MODE
This xture has the ability to accept custom static color settings. Access these chases via the control panel
on the back of the xture.
Press the button MENU so many times until the display shows Static, then press the button ENTER.
Select Fixed Color through the buttons UP/DOWN, then press the button ENTER.
6 Information
ð
Auto Test
ð
Test
Fixture Hours
ð
9999
Version
ð
V1.0
7 DMX Address
ð
1 - 512
8 DMX Channel
ð
5 Ch
7 Ch
10 Ch
9 Master/Slave
ð
Master
Slave
10 Fan Mode
ð
Auto
High
11 White Balance
ð
R = 255
ð
Value (125-255)
G = 255
ð
Value (125-255)
B = 255
ð
Value (125-255)
12 LED Frequency
ð
600 Hz
1200 Hz
2000 Hz
4000 Hz
25 KHz
13 Reverse Zoom
ð
No/Yes FW 1.41 and above
14 Temperature
ð
40°C
VERSAPAR
10
Set the colors R , G , B, W, GB, RB, RG, ,RGB, RW, GW, BW, RGW, RBW, GBW, RGBW, through the buttons UP/DOWN,
then press the button ENTER.
Press the MENU button to go back or to meet the waiting time to exit the setup menu.
3.6 MANUAL MODE
This mode allows to combine the colors red, green and blue (R, G, B).
Press the button MENU so many times until the display shows Static, then press the button ENTER.
Select Manual Color through the buttons UP/DOWN, then press the button ENTER.
Select the color R, G, B through the buttons UP/DOWN, then press the button ENTER.
Using UP/DOWN button, select the desired color value 000 - 255.
Press ENTER button to continue to the next color R, G, B.
Continue until the desired mix is obtained.
Press the MENU button to go back or to meet the waiting time to exit the setup menu.
3.7 MASTER/SLAVE MODE
This mode will allow you to link up the units together without a controller. Choose a unit to function as the
Master. The unit must be the rst unit in line; other units will work as slave.
Use standard DMX cables to daisy chain your units together via the DMX connector on the rear of the
units. For longer cable runs we suggest a terminator at the last xture (see page 13).
Set on master xture the desired program (see section 3.4).
Set the slaves to the same DMX modes.
3.8 LINKING
1. Connect the DMX OUT of the master unit via 3/5-pole XLR cable to the DMX IN of the rst slave unit.
2. Connect the DMX OUT of the rst slave unit to the DMX IN of the second slave unit, etc. until all units
are connected in a chain.
3.9 DMX MODE
Press the button MENU so many times until shows 5 Ch, 7 Ch or 10 Ch and press the button ENTER to
conrm.
Press the button UP/DOWN to select the desired DMX address 001 - 512. Press and hold to scroll quickly.
Press ENTER button to store.
Press the MENU button to go back or to meet the waiting time to exit the setup menu.
The tables on page 14 indicate the operating mode and DMX value. VERSAPAR is equipped with 3/5-pole
XLR connections.
3.10 DMX ADDRESSING
To able to operate the VERSAPAR with a light controller, adjust the DMX start address for the rst a DMX
channel. If e. g. address 33 on the controller is provided for controlling the function of the rst DMX chan-
nel, adjust the start address 33 on the VERSAPAR. The other functions of the light eect panel are then
automatically assigned to the following addresses.
An example with the start address 33 is shown below:
11
VERSAPAR
. . . . . . . . . . . .
DMX512 Controller
DMX Address: 33 DMX Address: 48DMX Address: 38 DMX Address: 43
Fig.5 - Example 5 DMX channels conguration
Number of
DMX channels
Start address
(example)
DMX Address
occupied
Next possible start
address for unit No. 1
Next possible start
address for unit No. 2
Next possible start
address for unit No. 3
5 33 33-37 38 43 48
VERSAPAR
12
Fig.6
Fig.7
3.11 CONNECTION OF THE DMX LINE
DMX connection employs standard XLR connectors. Use shielded pair-twisted cables with 120Ω imped-
ance and low capacity.
The following diagram shows the connection mode:
ATTENTION
The screened parts of the cable (sleeve) must never be connected to the system’s earth, as this would
cause faulty xture and controller operation.
Over long runs can be necessary to insert a DMX level matching amplier.
For those connections the use of balanced microphone cable is not recommended because it cannot
transmit control DMX data reliably.
Connect the controller DMX input to the DMX output of the rst unit.
Connect the DMX output to the DMX input of the following unit. Connect again the output to the input
of the following unit until all the units are connected in chain.
When the signal cable has to run longer distance is recommended to insert a DMX termination on the
last unit.
3.12 CONSTRUCTION OF THE DMX TERMINATION
The termination avoids the risk of DMX 512 signals being reected back along the cable when they reach-
es the end of the line: under certain conditions and with certain cable lengths, this could cause them to
cancel the original signals.
The termination is prepared by soldering a 120Ω 1/4 W resistor between pins 2 and 3 of the 5-pin male XLR
connector, as shown in gure.
DMX - OUTPUT
XLR socket
DMX - INPUT
XLR plug
Pin1 : GND - Shield
Pin2 : - Negative
Pin3 : + Positive
Pin4 : N/C
Pin5 : N/C
Example:
3 pin XLR connector
13
VERSAPAR
3.13 DMX CONTROL
5 CHANNEL
MODE
FUNCTION DMX
Value
5 Ch
1
RED
0~100% 000 - 255
2
GREEN
0~100% 000 - 255
3
BLUE
0~100% 000 - 255
4
WHITE
0~100% 000 - 255
5
ZOOM
0~100% 000 - 255
10 CHANNEL
MODE
FUNCTION DMX
Value
10 Ch
1
DIMMER
0~100% 000 - 255
2
RED
0~100% 000 - 255
3
GREEN
0~100% 000 - 255
4
BLUE
0~100% 000 - 255
5
WHITE
0~100% 000 - 255
6
COLOR MACROS
No Function
Color Macros
000 - 015
016 - 255
7
STROBE
No Function
Slow to fast
000 - 010
011 - 255
AUTO SPEED
Slow to fast 000 - 255
8
AUTO MODE
RGBW mode
Pulse eect 0~100%
Pulse eect 100%~0
Pulse eect 100%~0~100%
Auto fade transition
Auto snap transition (4 colors)
Auto snap transition (15 colors)
000-010
011-050
051-090
091-130
131-170
171-210
211-255
9
DIMMER SPEED
Preset dimmer speed from display menu
Dimmer speed mode o
Dimmer speed mode1 (fast speed)
Dimmer speed mode2 (middle speed)
Dimmer speed mode3 (slow speed)
000-051
052-101
102-152
153-203
204-255
10
ZOOM
0~100% 000 - 255
7 CHANNEL
MODE
FUNCTION DMX
Value
7 Ch
1
DIMMER
0~100% 000 - 255
2
RED
0~100% 000 - 255
3
GREEN
0~100% 000 - 255
4
BLUE
0~100% 000 - 255
5
WHITE
0~100% 000 - 255
6
STROBE
No Function
Slow to fast
000 - 010
011 - 255
7
ZOOM
0~100% 000 - 255
VERSAPAR
14
3.14 DIMMER
To enter dimmer mode and choose to simulate dierent dimming curves, press the MENU button re-
peatedly until the display shows Dimmer Mode, then press the ENTER button.
Press the button MENU repeatedly until Dimmer Mode shows, and press ENTER button to accept.
Use the button UP/DOWN to select a dimmer curve O - Dimmer1 - Dimmer2 - Dimmer3.
Press ENTER button to accept.
Press ENTER button to conrm the selection.
Press the MENU button to go back or to meet the waiting time to exit from the setup menu automati-
cally.
3.15 BACK LIGHT
To activate backlight display press the button MENU so many times until shows Back Light, and press the
button ENTER to conrm.
Press the button UP/DOWN to select On - 10S - 20S - 30S. Press ENTER button to conrm the selection.
Press the MENU button to go back or to meet the waiting time to exit from the setup menu automati-
cally.
3.16 FIXTURE INFORMATION
1. Press the MENU button so many times until shows Information, and then press ENTER button.
2. Use UP/DOWN button to select: Auto Test - Fixture Hours - Version.
3. Press ENTER button to conrm the selection.
4. Press the MENU button to go back or to meet the waiting time to exit from the setup menu automati-
cally.
Auto Test
This setting starts the products test sequence. Select Auto Test.
Fixture Hours
This option shows the user the amount of hours the VERSAPAR has been in use throughout its lifetime.
Select Fixture Hours.
Version
This option shows the user the software version currently installed in the unit. Select Version.
3.17 LED FREQUENCY
To adjust the frequency of the LEDs, press the MENU button repeatedly until the display shows LED
Frequency, and then press the ENTER button.
Select the frequency 600 Hz - 25 KHz using the UP/DOWN buttons.
To conrm, press the ENTER key.
Press the MENU button to go back or wait a few seconds to exit the setup menu.
3.18 TEMPERATURE
To read the value of the internal temperature of the device, press the MENU button repeatedly until the
display shows Temperature, and then press the ENTER key to read the value.
Press the MENU button to go back or wait a few seconds to exit the setup menu.
15
VERSAPAR
3.19 FAN MODE
To set the rotation speed of the fans refer to the following guide:
Press the MENU key repeatedly until the display shows Fan Mode, then press the button ENTER.
Select by pressing UP/DOWN one of the following options: Auto - High. It is possible choose the speed of
rotation of the fans from: fast High and automatic Auto.
Press the MENU button to go back or wait a few seconds to exit the setup menu.
3.20 WHITE BALANCE
Enter the White balance to adjust the Red, Green, and Blue parameter to make dierent whites.
Press the button MENU so many times until shows White Balance, and press the button ENTER to conrm.
Select the color R, G, B through the buttons UP/DOWN, then press the button ENTER.
Using UP/DOWN button, select the desired color value 125 - 255.
Press ENTER button to continue to the next color R, G, B.
Continue until the desired mix is obtained.
Press the MENU button to go back or to meet the waiting time to exit the setup menu.
VERSAPAR
16
- 4 - MAINTENANCE
4.1 MAINTENANCE AND CLEANING THE UNIT
Make sure the area below the installation place is free from unwanted persons during setup.
Switch o the unit, unplug the main cable and wait until the unit has cooled down.
All screws used for installing the device and any of its parts should be tightly fastened and should not
be corroded.
Housings, xations and installation spots (ceiling, trusses, suspensions) should be totally free from any
deformation.
The main cables must be in impeccable condition and should be replaced immediately even when a
small problem is detected.
It is recommended to clean the front at regular intervals, from impurities caused by dust, smoke, or
other particles to ensure that the light is radiated at maximum brightness. For cleaning, disconnect the
main plug from the socket. Use a soft, clean cloth moistened with a mild detergent. Then carefully wipe
the part dry. For cleaning other housing parts use only a soft, clean cloth. Never use a liquid, it might
penetrate the unit and cause damage to it.
4.2 FUSE REPLACEMENT
1. Remove the safety cap by a screwdriver.
2. Replace the blown fuse with a fuse of the exact same type and rating (T2A/250V).
3. Install the safety cap, and reconnect power.
4.3 TROUBLESHOOTING
Fig.8
Problems Possible causes Checks and remedies
Fixture does not light up
No mains supply
Dimmer fader set to 0
All color faders set to 0
Faulty LED
Faulty LED board
Check the power supply voltage
Increase the value of the dimmer channels
Increase the value of the color channels
Replace the LED board
Replace the LED board
General low light intensity
Dirty lens assembly Clean the xture regularly
Fixture does not power up
No power
Loose or damaged power cord
Faulty internal power supply
Check for power on power outlet
Check power cord
Replace internal power supply
Fixture does not respond to DMX
Wrong DMX addressing
Damaged DMX cables
Bouncing signals
Check control panel and unit addressing
Check DMX cables
Install terminator as suggested
Contact an authorized service center in case of technical problems or not reported in the table can not be
resolved by the procedure given in the table.
Music & Lights S.r.l. si riserva ogni diritto di elaborazione in qualsiasi forma delle presenti istruzioni per l’uso.
La riproduzione - anche parziale - per propri scopi commerciali è vietata.
Al ne di migliorare la qualità dei prodotti, la Music&Lights S.r.l. si riserva la facoltà di modicare, in
qualunque momento e senza preavviso, le speciche menzionate nel presente manuale di istruzioni.
Tutte le revisioni e gli aggiornamenti sono disponibili nella sezione 'Manuali' sul sito www.musiclights.it
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

ProLights VERSAPAR Manuale utente

Categoria
Stroboscopi
Tipo
Manuale utente

in altre lingue