Greenlee HW3 Impact Wrench Manuale utente

Categoria
Utensili elettrici
Tipo
Manuale utente
OPERATION MANUAL
HW3
Impact Wrench
Read and understand all of the instructions and
safety information in this manual before operating
or servicing this tool.
Register this product at www.greenlee.com
52063857 REV 1 © 2013 Greenlee Textron Inc. 6/13
Serial Code BBF
Español ............... 13
Français .............. 25
Deutsch .............. 37
Italiano ................ 49
HW3 Impact Wrench
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
2
Safety
Safety is essential in the use and maintenance of
Greenlee tools and equipment. This instruction manual
and any markings on the tool provide information for
avoiding hazards and unsafe practices related to the
use of this tool. Observe all of the safety information
provided.
Purpose of this Manual
This manual is intended to familiarize all personnel with
the safe operation and maintenance procedures for the
following Greenlee Utility hydraulic impact wrench:
HW3 Serial Code BBF
Keep this manual available to all personnel.
Replacement manuals are available upon request at no
charge at www.greenlee.com.
Other Publications
Tool Owners/Users
SAE Standard J1273 (Hose and Hose Assemblies):
Publication 99930323
Authorized Greenlee Utility Service Centers
Repair Manual: Publication 52063856
All specications are nominal and may change as design
improvements occur. Greenlee Textron Inc. shall not be liable for
damages resulting from misapplication or misuse of its products.
Cool Grip and Super Spool are trademarks of Textron Innovations Inc.
Super Spool™ is protected by U.S. Patent No. 4548229.
KEEP THIS MANUAL
Table of Contents
Description .................................................................... 2
Safety ............................................................................ 2
Purpose of this Manual ................................................. 2
Other Publications ......................................................... 2
Important Safety Information .....................................3–5
Identication .................................................................. 6
Specications ................................................................ 7
Setting the Super Spool™............................................. 8
Installing and Removing Accessories............................ 8
Hoses and Fittings ........................................................ 9
Typical Setup ................................................................. 9
Hose Connections ......................................................... 9
Setup ........................................................................... 10
Operation ................................................................ 10–11
Maintenance ................................................................ 11
Troubleshooting ........................................................... 12
Accessories ................................................................. 12
Description
The Greenlee Utility HW3 Impact Wrench is intended
for use with impact-type sockets, screwdriver bits,
and wood bits. The operating pressure range is 68.9 to
138bar (1000 to 2000 psi).
Features include:
Directional spool for forward or reverse operation
Insulated handle for operator comfort and safety
Impact and heat resistant Cool Grip™ handle covers
to dissipate heat
Super Spool™ for use on either open-center
or closed-center hydraulic systems
Pressure-compensated ow control to prevent over-
speeding at high ow rates
HW3 Impact Wrench
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
3
IMPORTANT SAFETY INFORMATION
SAFETY
ALERT
SYMBOL
This symbol is used to call your attention to hazards
or unsafe practices which could result in an injury or
property damage. The signal word, dened below,
indicates the severity of the hazard. The message
after the signal word provides information for pre-
venting or avoiding the hazard.
Immediate hazards which, if not avoided, WILL result
in severe injury or death.
Hazards which, if not avoided, COULD result in
severe injury or death.
Hazards or unsafe practices which, if not avoided,
MAY result in injury or property damage.
Read and understand all of the
instructions and safety information
in this manual before operating or
servicing this tool.
Failure to observe this warning could
result in severe injury or death.
Electric shock hazard:
This tool is not insulated. When using
this unit near energized electrical lines:
Use only certied non-conductive
hoses and proper personal protec-
tive equipment.
Select and maintain the hydraulic
uid to meet the minimum dielectric
standards required by your safety
department.
Failure to observe this warning could
result in severe injury or death.
Skin injection hazard:
Do not use hands to check for leaks.
Do not hold hose or couplers while
the hydraulic system is pressurized.
Depressurize the hydraulic system
before servicing.
Oil under pressure easily punctures
skin causing serious injury, gangrene,
or death. If you are injured by escaping
oil, seek medical attention immediately.
Wear eye protection when operating or
servicing this tool.
Failure to wear eye protection could
result in serious eye injury from ying
debris or hydraulic oil.
Wear hearing protection when using
this tool.
Failure to observe this warning could
result in serious injury.
HW3 Impact Wrench
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
4
IMPORTANT SAFETY INFORMATION
Some dust created by power sanding, sawing, grind-
ing, drilling, and other construction activities contains
chemicals known to the State of California to cause
cancer, birth defects or other reproductive harm. Some
examples of these chemicals are:
Lead from lead-based paints
Crystalline silica from bricks and cement and other
masonry products
Arsenic and chromium from chemically-treated
lumber.
To reduce your exposure to these chemicals: work in
a well ventilated area, and work with approved safety
equipment, such as dust masks that are specially
designed to lter out microscopic particles.
Use accessories that are approved for impact use
only. Accessories that are not approved for impact
applications can break when used with impact-type
tools.
Inspect accessories before use. Discard accessories
that have cracks, chips, or gouges.
Failure to observe this warning could result in severe
injury or death.
Keep all parts of the body away from rotating parts
when the tool is in operation. Contact with moving
parts can result in severe injury.
Do not change accessories, inspect, or clean tool when
it is connected to a power source. Accidental start-up
can result in serious injury.
Maintain a rm grip on tool, using both hands at all
times. Serious injury can result if an operator does
not control the tool.
Do not lock trigger in the power-ON position.
Operator can not stop tool when trigger is locked.
Failure to observe these warnings could result in
severe injury or death.
Tool and accessory may be hot during
and after operation.
Contact with hot surfaces could result
in serious injury.
Do not exceed the following hydraulic power source
maximums:
Hydraulic ow: 46 l/min (12 gpm)
Pressure relief: 138 bar (2000 psi)
Back pressure: 13.8 bar (200 psi)
Failure to observe this warning could result in severe
injury or death.
Do not disconnect tool, hoses, or ttings while
the power source is running or if the hydraulic uid is
hot. Hot hydraulic uid could cause serious burns.
Do not reverse hydraulic ow. Operation with hydraulic
ow reversed can cause tool malfunction. Connect the
supply (pressure) hose and return (tank) hose to the
proper tool ports.
Failure to observe this warning could result in severe
injury or death.
HW3 Impact Wrench
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
5
IMPORTANT SAFETY INFORMATION
Wear protective gloves when handling, removing
and installing drill bits. Drill bits can cut even when
stationary.
Inspect tool before use. Replace any worn or
damaged parts. A damaged or improperly
assembled tool can malfunction, injuring nearby
personnel.
Inspect the hydraulic hoses and couplings every
operating day. Repair or replace if leakage, cracking,
wear, or damage is evident. Damaged hoses or cou-
plings can fail, resulting in injury or property damage.
Use this tool for manufacturer’s intended use only.
Use other than that which is described in this
manual could result in injury or property damage.
Make sure all bystanders are clear of the work area
when handling, starting, and operating the tool.
Nearby personnel can be injured by ying parts in the
event of a tool malfunction.
Prolonged exposure to vibration or very repetitive hand
and arm movements may cause injury. Stop using
any tool if discomfort, tingling feeling, or pain occurs.
Consult a physician before resuming use of the tool.
Procedure for connecting or disconnecting hydraulic
hoses, ttings, or components:
1. Move the ow lever on the hydraulic power source
to the OFF position.
2. Stop the hydraulic power source.
3. Follow the sequence under “Hose Connections” to
prevent pressure buildup. In case some pressure
has built up, loosen hoses, ttings, or components
slowly.
Emergency stop procedure:
1. Release the trigger.
2. Shut off the hydraulic power source.
Note: Keep all decals clean and legible, and replace
when necessary.
HW3 Impact Wrench
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
6
Identification
1. Trigger
2. 3/4" Square Chuck
3. Drive Shank
4. Directional Decal
5. Warning Decal
6. Motor Cap
2
6
5
7
3
8
9
11
12
1
10
4
7. Serial Number
8. Directional Spool
9. Flow Control
10. OC/CC Trigger Spool
11. Return (Tank) Port
12. Pressure Port
HW3 Impact Wrench
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
7
Specifications
Impact Wrench
Type of Hydraulic System .............................Open-center
or closed-center
Hydraulic Pressure Port ...9/16–18 UNF SAE O-ring Boss
Hydraulic Return Port ........ 3/4–16 UNF SAE O-ring Boss
Output @ 30.3 l/min (8 gpm)
RPM (no load) ...................................................... 2800
Impacts per Minute (no load) ............................... 1300
Torque @ 37.8 l/min (10 gpm) .......... 1742 Nm (1285 ft-lb)
Drive Size ..............................................3/4" square drive
Vibration Level ...................................................15.3 m/s
2
Noise Level ..........................................................120 Lwa
Mass/Weight ........................................... 4.76 kg (10.5 lb)
Length ........................................................236 mm (9.3")
Width ..........................................................107 mm (4.2")
Height .......................................................300 mm (11.8")
Hydraulic Power Source
Do not exceed the following hydraulic power source
maximums:
Hydraulic ow: 46 l/min (12 gpm)
Pressure relief: 138 bar (2000 psi)
Back pressure: 13.8 bar (200 psi)
Failure to observe this warning could result in severe
injury or death.
Type of Hydraulic System .............................Open-center
or closed-center
Flow
Minimum ......................................... 15.1 l/min (4 gpm)
Recommended .............18.9 to 30.3 l/min (5 to 8 gpm)
Maximum ......................................... 46 l/min (12 gpm)
Filtration .............................................10 Micron (nominal)
Pressure Relief Setting ........................ 138 bar (2000 psi)
Back Pressure (maximum*) .................. 13.8 bar (200 psi)
* 13.8 bar (200 psi) is the maximum agreed standard back pressure
for the HTMA (Hydraulic Tool Manufacturers Association).
Greenlee Utility tool will operate satisfactorily at this standard.
1. Maximum hydraulic uid temperature must not
exceed 60 °C (140 °F). A sufcient oil cooling
capacity is needed to limit the hydraulic uid
temperature.
2. Hydraulic ow must not exceed 46 l/min (12 gpm).
Install a ow meter in the return line to measure the
rate of hydraulic ow before using the tool.
3. Pressure relief valve setting must not exceed
138 bar (2000 psi) at your tool’s maximum ow.
Locate the pressure relief valve in the supply circuit
to limit excessive hydraulic pressure to the tool.
Hydraulic Schematic
FILTER
(10 MICRON)
COOLER
RELIEF
VALVE
138 bar
(2000 psi)
CONTROL
VALVE
FLOW METER
T
P
TOOL
RESERVOIR
PUMP
POWER SOURCE
Recommended Hydraulic Fluids
Use any non-detergent, petroleum-based hydraulic
uid which meets the following specications or HTMA
specications.
S.U.S. @
38 °C (100 °F) ..............................................140 to 225
99 °C (210 °F) ........................................... 40 minimum
Flash Point ................................170 °C (340 °F) minimum
Pour Point .................................. -34 °C (-30 °F) minimum
Hydraulic Power Source (cont’d)
HW3 Impact Wrench
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
8
Setting the Super Spool™
The Super Spool allows the tool to be used with either
open-center or closed-center hydraulic systems.
1. Insert a screwdriver into the spool recess.
2. If using:
Open-center hydraulic system, turn the
Super Spool counterclockwise until it stops.
Closed-center hydraulic system, turn the
Super Spool clockwise until it stops.
OC CC
Installing and Removing Accessories
Use accessories that are approved for impact use
only. Accessories that are not approved for impact
applications can break when used with impact-type
tools.
Inspect accessories before use. Discard accessories
that have cracks, chips, or gouges.
Failure to observe this warning could result in severe
injury or death.
Impact Bits and Screwdriver Bits
Greenlee Utility recommends using Greenlee impact-
style bits.
Some bits may whip or bend under sideload.
Do not use bits with a long spiral and center support.
When using an impact bit, run the power source at
minimum ow.
Failure to observe these warnings could result in
severe injury or death.
Long SpiralCenter Support
x
1. Inspect the quick change chuck, if equipped.
Remove any dirt or other contamination.
2. Slide and hold the chuck away from the tool and
remove the adapter.
3. Insert the drill bit into the tool and release the chuck.
4. To remove the drill bit, slide and hold the chuck
away from the tool and remove the bit.
HW3 Impact Wrench
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
9
Hoses and Fittings
Installation and Maintenance
Refer to publication 99930323, SAE J1273
(Hose and Hose Assemblies).
Replacement
Refer to a Greenlee Utility catalog or publication
99910322, Low Pressure Quick Couplers, Adapters
andHoses.
Do not disconnect tool, hoses, or ttings while
the power source is running or if the hydraulic uid is
hot. Hot hydraulic uid could cause serious burns.
Hose Connections
Tool Port Identification
Match the markings on your tool to this table.
Pressure Port Return Port
P T
or
Connecting Hoses
1. Move the ow lever on the hydraulic power source
to the OFF position.
2. Stop the hydraulic power source.
3. Connect the return hose to the return port on the
hydraulic power source, and then to the return port
on the tool.
4.
Connect the pressure hose to the pressure port on the
tool, then to the pressure port on the hydraulic power
source.
Disconnecting Hoses
1. Move the ow lever on the hydraulic power source
to the OFF position.
2. Stop the hydraulic power source.
3. Disconnect the pressure hose from the hydraulic
power source, and then from the tool.
4. Disconnect the return hose from the tool, and then
from the hydraulic power source.
5. Install dust caps over the ports to prevent
contamination.
Typical Setup
HW3 Impact Wrench
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
10
Setup
Do not exceed the following hydraulic power source
maximums:
Hydraulic ow: 46 l/min (12 gpm)
Pressure relief: 138 bar (2000 psi)
Back pressure: 13.8 bar (200 psi)
Failure to observe this warning could result in severe
injury or death.
Do not reverse hydraulic ow. Operation with hydraulic
ow reversed can cause tool malfunction. Connect the
supply (pressure) hose and return (tank) hose to the
proper tool ports.
Failure to observe this warning could result in severe
injury or death.
1. Stop the hydraulic power source.
2. Install an accessory according to the instructions
under “Installing and Removing Accessories.”
3. Connect the tool to the power source according to
the instructions under “Hose Connections.”
Operation
Electric shock hazard:
This tool is not insulated. When using
this unit near energized electrical lines:
Use only certied non-conductive
hoses and proper personal protec-
tive equipment.
Select and maintain the hydraulic
uid to meet the minimum dielectric
standards required by your safety
department.
Failure to observe this warning could
result in severe injury or death.
Skin injection hazard:
Do not use hands to check for leaks.
Do not hold hose or couplers while
the hydraulic system is pressurized.
Depressurize the hydraulic system
before servicing.
Oil under pressure easily punctures
skin causing serious injury, gangrene,
or death. If you are injured by escaping
oil, seek medical attention immediately.
Do not change accessories, inspect or clean tool when it
is connected to a power source. Accidental start-up can
result in serious injury.
Failure to observe this warning could result in severe
injury or death.
Wear eye protection when operating or
servicing this tool.
Failure to wear eye protection could
result in serious eye injury from ying
debris or hydraulic oil.
Emergency stop procedure:
1. Release the trigger.
2. Shut off the hydraulic power source.
HW3 Impact Wrench
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
11
Maintenance
Wear eye protection when operating or
servicing this tool.
Failure to wear eye protection could
result in serious eye injury from ying
debris or hydraulic oil.
Do not change accessories, inspect, or clean tool when it
is connected to a power source. Accidental start-up can
result in serious injury.
Failure to observe this warning could result in severe
injury or death.
Use this maintenance schedule to maximize the tool’s
service life.
Note:
Keep all decals clean and legible, and replace when
necessary.
When disposing of any components (hydraulic hoses,
hydraulic fluid, worn parts, etc.), do so in accordance
with federal, state, and local laws or ordinances.
Daily
1. Wipe all tool surfaces clean.
2.
Inspect the hydraulic hoses and ttings for signs of
leaks, cracks, wear, or damage. Replace if necessary.
3. Install dust caps over the hydraulic ports when the
tool is disconnected.
Monthly
Perform a thorough inspection of the hydraulic hoses
and ttings as described in publication 99930323,
SAE J1273 (Hose and Hose Assemblies).
Operation (cont’d)
1. Start the power source.
Note: Allow the power source to run for a few
minutes to warm the hydraulic fluid.
2. Set the directional spool to the appropriate position
(forward or reverse).
Do not change the position of the directional spool
while the tool is operating. Allow the tool to stop
before changing direction.
Failure to observe this precaution can result in
property damage.
3. Grasp the handle. Place your other hand on the top
of the tool or on the auxiliary handle. This will allow
you to apply leverage while operating the tool.
4. To start the tool, squeeze the trigger.
If 5 seconds of impacting does not loosen a bolt,
nut, etc., stop impacting and use some other
method of removal. Continued impacting will cause
severe wear on the impact mechanism.
5. To stop the tool, release the trigger.
6. When the tool is not in use, stop the power source
to reduce heat and wear on tool components.
HW3 Impact Wrench
Problem Probable Cause Probable Remedy
Tool does not
operate.
Improper power source. Refer to “Specications.” Verify that the power source
meets the specications.
Hydraulic uid level low. Check the uid level. Check system for leaks.
Incorrect hydraulic uid viscosity. Refer to “Recommended Hydraulic Fluids” in the
“Specications” section.
Tool operates slowly
or
erratically.
Hydraulic uid cold. Allow uid to warm to the operating temperature. Actuate
the tool intermittently to reduce the warming time.
Hose connections at tool reversed. Depressurize hydraulic system. Switch the hose
connections.
Power source not adjusted correctly. Refer to the power source operator’s manual for setting
the ow and pressure. Set the ow and pressure to
correspond with the tool.
Air in the hydraulic system. Refer to the power source manufacturer’s instructions for
removing air from the system.
Incorrect hydraulic uid viscosity. Refer to “Recommended Hydraulic Fluids” in the
“Specications” section.
Tool feels hot. Hydraulic uid level low. Check the uid level. Check system for leaks.
Incorrect hydraulic uid viscosity. Refer to “Recommended Hydraulic Fluids” in the
“Specications” section.
Hydraulic uid dirty. Drain reservoir, ush, and ll with clean uid. Change lter.
Before troubleshooting, determine whether the problem
is in the tool, the hoses, or the power source. Substitute
a tool, hoses, or power source known to be in good
working order to identify the item that is not operating.
Troubleshooting
If the problem is in the tool, see the troubleshoot-
ing table below. If the problem is in the power source,
see the troubleshooting section of the power source
instruction manual.
Accessories
Adapters, impact bits, and sockets are available through
your Greenlee Utility distributor. For a complete list of
accessories, refer to our catalog or visit our web site
at www.greenlee.com.
4455 Boeing Drive • Rockford, IL 61109-2988 • USA • 815-397-7070
An ISO 9001 Company • Greenlee Textron Inc. is a subsidiary of Textron Inc.
USA
Tel: 800-435-0786
Fax: 800-451-2632
Canada
Tel: 800-435-0786
Fax: 800-524-2853
International
Tel: +1-815-397-7070
Fax: +1-815-397-9247
www.greenlee.com
MANUAL DE OPERACIÓN
Lea y entienda todas las instrucciones y la
información sobre seguridad que aparecen en
este manual, antes de manejar esta herramienta
o darle mantenimiento.
Registre este producto en www.greenlee.com
Llave de percusión
HW3
52063857 © 2013 Greenlee Textron Inc. 3/13
Código de serie BBF
Llave de percusión HW3
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
14
Acerca de la seguridad
Es fundamental observar métodos seguros al utilizar
y dar mantenimiento a las herramientas y equipo
Greenlee. Este manual de instrucciones y todas
las marcas que ostenta la herramienta le ofrecen la
información necesaria para evitar riesgos y hábitos
poco seguros relacionados con su uso. Siga toda la
información sobre seguridad que se proporciona.
Propósito de este manual
Este manual tiene como propósito familiarizar a todo
el personal con los procedimientos de operación y
mantenimiento seguros para la siguiente llave hidráulica
de percusión de Greenlee Utility:
HW3 Código de serie BBF
Manténgalo siempre al alcance de todo el personal.
Puede obtener copias adicionales de manera gratuita,
previa solicitud en www.greenlee.com.
Otras publicaciones
Para propietarios o usuarios
Norma SAE J1273 (Manguera y conjuntos
de mangueras): Publicación 99930323
Centros de Servicio Autorizado Greenlee Utility
Manual de Reparación: Publicación 52063856
Todas las especicaciones son nominales y pueden cambiar conforme
tengan lugar mejoras de diseño. Greenlee Textron Inc. no se hace
responsable de los daños que puedan surgir de la mala aplicación o
mal uso de sus productos.
Cool Grip y Super Spool son marcas de Textron Innovations Inc.
Super Spool está protegido por la patente esta douni dense
No. 4548229.
CONSERVE ESTE MANUAL
Índice
Descripción ................................................................. 14
Acerca de la seguridad ................................................ 14
Propósito de este manual ........................................... 14
Otras publicaciones .................................................... 14
Importante información sobre seguridad ...............15–17
Identicación ............................................................... 18
Especicaciones ......................................................... 19
Montaje del Super Spool™ ......................................... 20
Montaje y desmontaje de accesorios ......................... 20
Mangueras y accesorios ............................................. 21
Conexión de las mangueras ........................................ 21
Modelo de instalación ................................................. 21
Instalación ................................................................... 22
Operación ...............................................................22–23
Mantenimiento ............................................................. 23
Solución de problemas ............................................... 24
Accesorios ................................................................... 24
Descripción
La llave de percusión HW3 de Greenlee Utility ha sido
diseñada para utilizarse con casquillos, puntas de
destornilladores y brocas para madera de percusión.
La escala de presión de funcionamiento es 68,9 a
138bar (1000 a 2000 psi).
Sus características incluyen lo siguiente:
Bobina direccional para funcionamiento de avance o
en reversa
Empuñadura aislada para la comodidad y seguridad
del operador
Protecciones para empuñadura Cool Grip™
resistentes a los impactos y al calor para disipar el
calor
Super Spool™ para el uso en sistemas hidráulicos de
circuito abierto o de circuito cerrado
Control de ujo con compensación de presión para
prevenir la sobrevelocidad a altas tasas de ujo
Llave de percusión HW3
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
15
IMPORTANTE INFORMACIÓN SOBRE SEGURIDAD
SÍMBOLO
DE ALERTA
SOBRE
SEGURIDAD
Este símbolo se utiliza para indicar un riesgo
o práctica poco segura que podría ocasionar
lesiones o daños materiales. Cada uno de los
siguientes términos denota la gravedad del riesgo.El
mensaje que sigue a dichos términos le indica cómo
puede evitar o prevenir dicho riesgo.
Peligros inmediatos que, de no evitarse,
OCASIONARÁN graves lesiones o incluso la muerte.
Peligros que, de no evitarse, PODRÍAN
OCASIONAR graves lesiones o incluso la muerte.
Peligro o prácticas peligrosas que, de no evitarse,
PUEDEN OCASIONAR lesiones o daños materiales.
Lea y entienda todas las instrucciones
y la información sobre seguridad
que aparecen en este manual, antes
de manejar esta herramienta o darle
mantenimiento.
De no observarse esta advertencia
podrían sufrirse graves lesiones o
incluso la muerte.
Peligro de electrocución:
Esta herramienta no está aislada. Al
utilizar esta unidad cerca de líneas
eléctricas energizadas:
Utilice únicamente mangueras no
conductivas aprobadas y equipo de
protección personal adecuado.
Seleccione siempre un líquido para
aparatos hidráulicos, que cumpla con
los estándares dieléctricos mínimos
exigidos por su departamento de
seguridad, y manténgalo al nivel
adecuado.
De no observarse esta advertencia
podrían sufrirse graves lesiones o
incluso la muerte.
Peligro de inyección cutánea:
No use las manos para localizar
fugas.
No toque la manguera ni los
acopladores mientras el sistema
hidráulico se encuentre presurizado.
Purgue la presión en el sistema
hidráulico antes de darle mantenimiento.
El aceite bajo presión punza la
piel fácilmente provocando graves
lesiones, gangrena o la muerte. Si se
lesiona debido a una fuga de aceite,
solicite atención médica de inmediato.
Utilice protectores para ojos al
manejar o darle mantenimiento a esta
herramienta.
De no utilizar protectores para
ojos podría sufrir graves lesiones
oculares ocasionadas si el aceite
para aparatos hidráulicos, o restos de
materiales llegaran a saltar.
Llave de percusión HW3
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
16
IMPORTANTE INFORMACIÓN SOBRE SEGURIDAD
Al manejar esta herramienta utilice
protección auditiva.
De no observarse esta advertencia
podrían sufrirse lesiones graves.
Algunos polvos generados por el lijado, aserrado,
amolado, taladrado con herramienta eléctrica y otras
actividades de construcción contienen sustancias
químicas que el Estado de California conoce como
causantes de cáncer, defectos congénitos u otros
daños al sistema reproductor. Algunos ejemplos de
estos químicos son los siguientes:
Plomo de las pinturas con base de plomo
Sílice cristalina de los ladrillos y cementos, y de
otros productos de mampostería
Arsénico y cromo de la madera tratada
químicamente.
A n de reducir su exposición a estas sustancias
químicas: trabaje en un área bien ventilada, y
trabaje con equipo de seguridad apropiado, tal
como mascarillas contra polvo que están diseñadas
especialmente para ltrar partículas microscópicas.
Utilice únicamente accesorios aprobados para
aplicaciones donde sea necesaria la fuerza
por percusión. Los accesorios que no han sido
aprobados para este tipo de aplicaciones se pueden
quebrar al utilizarse con herramientas de percusión.
Revise minuciosamente los accesorios antes de
utilizarlos. Deseche aquellos que presenten grietas,
desportilladuras o mellas.
De no observarse esta advertencia podrían sufrirse
graves lesiones o incluso la muerte.
Mantenga todas las partes del cuerpo alejadas de
las piezas giratorias siempre que la herramienta esté
en funcionamiento. El contacto con las piezas en
movimiento puede ocasionar graves lesiones.
No cambie accesorios ni inspeccione o limpie la
herramienta mientras esté conectada a una fuente
de potencia. Si se activa accidentalmente, podría
ocasionar graves lesiones.
Siempre sostenga la herramienta rmemente con
ambas manos. Si pierde el control de la unidad
podría ocasionar graves lesiones.
No trabe el gatillo en la posición “ON”. El operador
no podrá detener la herramienta si se encuentra
trabada en dicha posición.
De no observarse estas advertencias podrían sufrirse
lesiones graves o incluso la muerte.
Tanto la herramienta como los
accesorios pueden alcanzar
temperaturas sumamente altas
mientras están en operación o incluso
una vez que han sido apagados.
El contacto con supercies calientes
podría producir lesiones graves.
No exceda los máximos especicados a continuación
para la fuente de potencia hidráulica:
Gasto hidráulico: 46 l/min
Presión de seguridad: 138 bar
Contrapresión: 13,8 bar
De no observarse esta advertencia podrían sufrirse
graves lesiones o incluso la muerte.
No desconecte la herramienta, ni las mangueras
o accesorios mientras la fuente de energía esté
encendida o el líquido hidráulico esté caliente.
El líquido hidráulico caliente podría ocasionar
quemaduras graves.
Llave de percusión HW3
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
17
IMPORTANTE INFORMACIÓN SOBRE SEGURIDAD
No invierta el gasto hidráulico. Operar la herramienta
con el gasto invertido ocasionará un funcionamiento
inadecuado. Conecte las mangueras de suministro
(presión) y la de retorno (tanque), en los oricios
correspondientes en la herramienta.
De no observarse esta advertencia podrían sufrirse
graves lesiones o incluso la muerte.
Utilice guantes protectores al manipular, retirar o
colocar las brocas; éstas pueden cortar incluso
cuando no están en movimiento.
Revise la herramienta antes de utilizarla.
Reemplace cualquier pieza desgastada o dañada.
Una herramienta dañada o montada de manera
incorrecta tendrá un funcionamiento errático y
puede lesionar al personal que se encuentre en el
área.
Revise minuciosamente las mangueras hidráulicas
y los acoplamientos cada vez que vaya a utilizar la
herramienta. Repárelos o reemplácelos si presentan
fugas, grietas, desgaste o daños evidentes. Las
mangueras y acoplamientos averiados pueden fallar
y ocasionar lesiones o daños materiales.
Utilice la herramienta únicamente para el uso para el
que ha sido diseñada por el fabricante. Si se utiliza
una manera distinta a la descrita en este manual
puede ocasionarse lesiones o daños materiales.
Asegúrese de que no haya circunstantes en el área
de trabajo al manipular la herramienta, ponerla
en funcionamiento o manejarla, El personal del
área podría sufrir lesiones si alguna pieza saliera
disparada al haber un desperfecto de la herramienta.
La exposición prolongada a la vibración o movimientos
muy repetidos de manos y brazos puede causar
lesiones. Detenga el uso de cualquier herramienta si
siente incomodidad, hormigueo o dolor. Consulte a un
médico antes de reanudar el uso de la herramienta.
Procedimiento para conectar o desconectar las
mangueras, accesorios o demás componentes
hidráulicos:
1. Coloque la palanca de gasto –ubicada en la fuente
de potencia hidráulica– en la posición de apagado
(OFF).
2. Apague la fuente de potencia hidráulica.
3. Siga la secuencia detallada en “Conexión de
las mangueras” a n de evitar una acumulación
de presión. En caso de que esto ocurra, aoje
lentamente las mangueras, los accesorios o los
componentes.
Procedimiento de apagado de emergencia:
1. Suelte el gatillo.
2. Apague la fuente de potencia hidráulica.
Aviso: Mantenga limpias y legibles todas las
calcomanías y reemplácelas cuando sea necesario.
Llave de percusión HW3
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
18
Identificación
1. Gatillo
2. Portabrocas cuadrado de
3/4 pulg.
3. Espiga motriz
4. Calcomanía de la dirección
5. Calcomanía de advertencia
6. Tapa del motor
2
6
5
7
3
8
9
11
12
1
10
4
7. Número de serie
8. Bobina direccional
9. Control de ujo
10. Carrete con accionador de circuito
abierto o de circuito cerrado (OC/CC)
11. Oricio de retorno (tanque)
12. Oricio de presión
Llave de percusión HW3
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
19
Especificaciones
Llaves hidráulica de percusión
Tipo de sistema hidráulico .......................Circuito abierto
o Circuito cerrado
Oricio de presión hidráulica ..............9/16–18 UNF SAE,
Aro tórico Boss
Oricio de retorno hidráulico ................ 3/4–16 UNF SAE,
Aro tórico Boss
Salida @ 30,3 l/min
RPM (sin carga) ................................................... 2.800
Percusiones por minuto (sin carga) ..................... 1.300
Par de torsión @ 37,8 l/min ................................1742 Nm
Tamaño del accionamiento ...................... Accionamiento
cuadrado de 3/4 pulg.
Nivel de vibración .............................................. 15,3 m/s
2
Nivel de ruido ......................................................120 Lwa
Masa/Peso ........................................................... 4,76 kg
Largo ...................................................................236 mm
Ancho .................................................................. 107 mm
Altura ................................................................... 300 mm
Fuente de potencia hidráulica
No exceda los máximos especicados a continuación
para la fuente de potencia hidráulica:
Gasto hidráulico: 46 l/min
Presión de seguridad: 138 bar
Contrapresión: 13,8 bar
De no observarse esta advertencia podrían sufrirse
graves lesiones o incluso la muerte.
Tipo de sistema hidráulico .......................Circuito abierto
o Circuito cerrado
Gasto
Mínimo ......................................................... 15,1 l/min
Recomendado ................................... 18,9 a 30,3 l/min
Máximo ........................................................... 46 l/min
Filtración ........................................10 micrones (régimen)
Ajuste de la presión de seguridad ........................ 138 bar
Contrapresión (máxima*) .....................................13,8 bar
* 13,8 bar es la contrapresión máxima acordada bajo las normas de
la HTMA (Hydraulic Tool Manufacturers Association o Asociación
de Fabricantes de Herramientas Hidráulicas). La herramienta
Greenlee Utility funcionará de manera satisfactoria según estas
normas.
1. La temperatura máxima del líquido para aparatos
hidráulicos no debe exceder 60°C. Es indispensable
contar con suciente capacidad de enfriamiento del
aceite, a n de controlar la temperatura del líquido
para aparatos hidráulicos.
2. El gasto hidráulico no debe exceder 46 l/min. Instale
un medidor de gasto en la línea de retorno para
medir la velocidad del gasto hidráulico antes de
utilizar la herramienta.
3. El ajuste de la válvula de presión de seguridad
no debe sobrepasar 138 bar al gasto máximo de
su herramienta. Localice la válvula de presión de
seguridad en el circuito de suministro para limitar un
exceso de presión hidráulica a la herramienta.
Diagrama hidráulico
FILTRO
(10 MICRONES)
ENFRIADOR
VÁLVULA DE PRESIÓN DE
SEGURIDAD
138 BAR
(2000 PSI)
VÁLVULA DE
CONTROL
MEDIDOR DE FLUJO
T
P
HERRAMIENTA
TANQUE
BOMBA
FUENTE DE ENERGÍA
Líquidos recomendados para aparatos hidráulicos
Utilice un líquido para aparatos hidráulicos, sin
detergente, con base de petróleo y que cumpla con las
siguientes especicaciones de la HTMA.
S.U.S. @
38°C ............................................................ 140 a 225
99°C ............................................................ 40 mínimo
Punto de inamación ................................. 170°C mínimo
Punto de temperatura
de descongelación .................................-34°C mínimo
Fuente de potencia hidráulica (continuación)
Llave de percusión HW3
Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
20
Montaje del Super Spool™
El Super Spool permite que la herramienta pueda
utilizarse tanto en sistemas hidráulicos de circuito
abierto como de circuito cerrado.
1. Introduzca un destornillador en la ranura de la
bobina.
2. Si está utilizando:
un sistema hidráulico de circuito abierto, gire el
Super Spool en sentido contrario a las manillas
del reloj hasta que tope.
un sistema hidráulico de circuito cerrado, gire el
Super Spool en el sentido de las manillas del reloj
hasta que tope.
OC CC
Montaje y desmontaje de accesorios
Utilice únicamente accesorios aprobados para
aplicaciones donde sea necesaria la fuerza
por percusión. Los accesorios que no han sido
aprobados para este tipo de aplicaciones se pueden
quebrar al utilizarse con herramientas de percusión.
Revise minuciosamente los accesorios antes de
utilizarlos. Deseche aquellos que presenten grietas,
desportilladuras o mellas.
De no observarse esta advertencia podrían sufrirse
graves lesiones o incluso la muerte.
Brocas de percusión y Puntas de destornilladores
Greenlee Utility recomienda el uso de las brocas de
percusión Greenlee.
Es posible que algunos tipos de brocas se doblen o
latigueen cuando sean sometidas a cargas laterales.
No utilice brocas con un espiral largo y soporte
central.
Cuando utilice brocas de percusión, establezca la
energía a un ujo mínimo.
De no observarse estas advertencias podrían sufrirse
lesiones graves o incluso la muerte.
Espiral largoSoporte central
x
1. Inspeccione el portabrocas de cambio rápido, de
estar incluido. Remueva cualquier rastro de polvo o
contaminación.
2. Deslice y mantenga el portabrocas alejado de la
herramienta y extraiga el adaptador.
3. Introduzca la broca en la herramienta y suelte el
portabrocas.
4. Para extraer la broca, deslice y mantenga el
portabrocas alejado de la herramienta y extraiga la
broca.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Greenlee HW3 Impact Wrench Manuale utente

Categoria
Utensili elettrici
Tipo
Manuale utente