Sentiotec Home combi Manuale utente

Tipo
Manuale utente
Version 04/23 Ident. no. Y05-0614
INSTRUCTIONS FOR INSTALLATION AND USE
English
EN
DE
FR
IT
NL
CS
SV
FI
Sauna heater
Home combi
HOME-C60 / 1-050-408: Home combi 6.0 kW
HOME-C90 / 1-050-411: Home combi 9.0 kW
EN: Overheat protector of the device can
go o also at temperatures below -5˚C /
23˚F (storage, transport, environment).
Before installation take the device to the
warm environment. The overheat protector
can be reset when the temperature of the
device is approx 18˚C / 64˚F. The over-
heat protector must be reset before using
the device. See the user manual > Reset-
ting the Overheat Protector.
DE: Der Überhitzungsschutz des Geräts
kann auch bei Temperaturen unter -5 °C
/ 23˚F (Lagerung, Transport, Umgebung)
auslösen. Bringen Sie das Gerät vor der
Installation in eine warme Umgebung.
Der Überhitzungsschutz kann bei einer
Gerätetemperatur von ca. 18 °C / 64˚F
zurückgesetzt werden. Vor Verwendung
des Geräts muss der Überhitzungsschutz
zurückgesetzt werden. Siehe Betriebsan-
leitung > Zurücksetzen des Überhitzungs-
schutzes.
FR: La sécurité-surchaue de l’appa-
reil peut également se déclencher à des
températures inférieures à -5 ˚C / 23 ˚F
(stockage, transport, environnement).
Avant l’installation, placez l’appareil dans
un endroit chaud. La sécurité-surchaue
peut être réinitialisée quand la tempéra-
ture de l’appareil se situe à env. 18 ˚C / 64
˚F. La sécurité-surchaue doit être réinitia-
lisée avant d’utiliser cet appareil. Repor-
tez-vous au manuel > Réinitialisation de la
sécurité-surchaue.
IT: La protezione da surriscaldamento del
dispositivo può attivarsi anche a tempera-
ture inferiori a -5°C/23°F (conservazione,
trasporto, ambiente). Prima dell’installa-
zione, portare il dispositivo in un ambiente
caldo. La protezione da surriscaldamento
può essere reimpostata quando la tempe-
ratura del dispositivo è di circa 18˚C/64˚F.
La protezione da surriscaldamento deve
essere reimpostata prima di utilizzare il
dispositivo. Vedere il manuale dell’utente
> Reimpostazione della protezione da sur-
riscaldamento.
!
EN
DE
FR
IT
NL
CS
SV
FI
NL: De oververhittingsbeveiliging van het
apparaat kan ook afgaan bij temperaturen
onder -5 ˚C/23 ˚F (opslag, transport, om-
geving). Breng het apparaat vóór de instal-
latie naar een warme omgeving. De over-
verhittingsbeveiliging kan worden gereset
als de temperatuur van het apparaat ca.
18 ˚C/64 ˚F bedraagt. De oververhittings-
beveiliging moet worden gereset voordat
u het apparaat gebruikt. Zie de gebrui-
kershandleiding > Oververhittingsbeveili-
ging resetten.
CS: Ochrana proti přehřátí se také může
vypnout při teplotách pod -5˚C / 23˚F (skla-
dování, přeprava, prostředí). Před instala-
umístěte zařízení do teplého prostředí.
Ochranu proti přehřátí je možné resetovat,
pokud je teplota zařízení přibl. 18˚C / 64˚F.
Před použitím zařízení je nutné ochranu
proti přehřátí resetovat. Viz uživatelský ná-
vod > Reset ochrany proti přehřátí.
SV: Enhetens överhettningsskydd kan
även lösa ut när temperaturen understi-
ger -5˚C / 23˚F (lagring, transport, omgiv-
ningsmiljö). Innan du installerar enheten
bör den stå i en varm miljö en stund.
Återställning är möjlig när enhetens tem-
peratur ligger på ca 18 ˚C / 64˚F. Överhett-
ningsskyddet måste återställas innan en-
heten tas i bruk. Se användarhandboken >
Återställning av överhettningsskyddet.
FI: Laitteen ylikuumenemissuoja voi laueta
myös alle -5˚C lämpötiloissa (varastointi,
kuljetus, ympäristö). Ennen asentamista
ota laite lämpimään. Ylikuumenemissuojan
voi kuitata laitteen ollessa noin 18 asteinen.
Kuittaa laitteen ylikuumenemissuoja ennen
käyttöönottoa > Ks. ylikuumenemissuojan
kuittaus laitteen käyttöohjeesta.
Table of Contents
1. About this instruction manual 4
2. Important information for your safety 5
2.1. Intended use 5
2.2. Safety information for the installer 6
2.3. Safety information for the user 7
3. Product description 8
3.1. Scope of delivery 8
3.2. Accessories 8
3.3. Product features 8
4. Installation and connection 8
4.1. Installation location and sensor position 9
4.2. Safety distances 9
4.3. Installation on the cabin wall 10
4.4. Connection diagram for 400 V 3 N~ 12
4.5. Connection diagram for 230 V 1 N~ 13
4.6. Wiring diagrams 14
4.7. Electrical connection 14
5. Commissioning 16
5.1. Filling the stone container 16
5.2. Heating for the rst time 17
6. Operation 18
6.1. Operating the sauna heater 18
6.2. Finnish sauna mode 18
6.3. Combi mode 19
EN
7. Maintenance 21
7.1. Extended periods of non-use 21
7.2. Cleaning the sauna heater 21
7.3. Changing the sauna stones 22
7.4. Cleaning the evaporator tank 22
7.5. Descaling the evaporator tank 23
8. Disposal 23
9. Problem-solving by the installer 24
10. Technical data 25
11. Spare parts 26
Instructions for installation and use p. 6/28
1. About this instruction manual
Carefully read these instructions for installation and use, and keep them near
the sauna. This ensures that you can refer to information on safety and operation
at any time.
Symbols used for warning notices
In these instructions for installation and use, a warning notice located next to
an activity indicates that this activity poses a risk. Always observe the warning
notices. This prevents damage to property and injuries, which in the worst case
may be fatal.
The warning notices contain keywords, which have the following meanings:
DANGER!
Serious or fatal injury will occur if this warning notice is not observed.
WARNING!
Serious or fatal injury can occur if this warning notice is not observed.
CAUTION!
Minor injuries can occur if this warning notice is not observed.
NOTE!
This keyword is a warning that damage to property can occur.
Other symbols
This symbol indicates tips and useful information.
Do not cover Read the operating instructions
These installation and operating instructions can also be found in
the downloads section of our website: www.sentiotec.com/downloads.
EN
Instructions for installation and use p. 7/28
2. Important information for your safety
The Home combi sauna heater has been produced in accordance
with the applicable safety rules and regulations. However, hazards
may arise during use. Therefore adhere to the following safety infor-
mation and the specic warning notices in the individual chapters.
2.1. Intended use
The Home combi is a sauna heater with integrated evaporator.
The Home combi may only be used for heating sauna cabins and
for increasing the humidity inside the sauna cabin. The Home combi
may only be used in conjunction with a sauna control unit without
a remote start function.
The Home combi sauna heater can also be used with a sauna
control unit with a remote start function, but only in conjunction with
the optional safety shutdown feature.
The Home combi sauna heater can also be used in public saunas,
but only in conjunction with the optional safety shutdown feature.
Any use exceeding this scope is considered improper use. Improper
use can result in damage to the product, severe injuries or death.
Instructions for installation and use p. 8/28
2.2. Safety information for the installer
Installing and connecting the sauna heater may only be performed
when the power supply is disconnected.
Installation may only be performed by a qualied electrician or
similarly qualied person.
A fully disconnecting all-pole isolating device compliant with
overvoltage category III must be tted on site.
Always use silicone cables that are heat-resistant up to 150 °C
to connect the sauna heater.
Only install one sauna heater in the cabin. The Home n sauna
heater must not be used together with other sauna heaters in
a sauna cabin.
The roof and walls of the sauna cabin must be manufactured from
low-resin, untreated or thermally treated wood, e.g. Nordic spruce,
hemlock, pine or r, or from laminated wooden materials. If lami-
nated wooden materials are used, make sure that the adhesive
used in them does not give o formaldehyde. If other materials
than wood are used in the sauna cabin, these materials must be
heat-resistant and corrosion-resistant and must not cause any
negative eects on the health of the sauna users.
The height of the sauna cabin must be at least 1.9 m.
Observe the specications on volumes and on ventilation of
the sauna cabin in chapter 10. Technical data on page 27.
When positioning the sauna heater, observe the minimum safety
distances (see chapter 4.2. Safety distances).
Also comply with the regulations applicable at the installation
location.
For your own safety, consult your supplier in the event of prob-
lems that are not explained in sucient detail in the installation
instructions.
EN
Instructions for installation and use p. 9/28
2.3. Safety information for the user
The device must not be used by children under 8 years of age.
The device may only be used by children over 8 years of age,
by persons with limited psychological, sensory or mental capa-
bilities or by persons with lack of experience/knowledge under
the following conditions:
They are supervised.
They have been shown how to use the device safely and
are aware of the hazards that could occur.
Children must not play with the device.
Children under 14 years of age may only clean the device if they
are supervised.
For health reasons, do not use the sauna when under the inu-
ence of alcohol, medication or drugs.
Never operate the sauna heater without sauna stones, as this
can cause res.
Make sure that no ammable objects have been placed on the sau-
na heater before the sauna control unit is switched on.
Heat up the sauna heater for half an hour BEFORE using the sau-
na for the rst time. Do NOT remain in the sauna cabin during
this period. Then ventilate the sauna cabin well (see 5.2. Heating
for the rst time on page 19).
Never touch the sauna heater while it is operating. The surfaces
of the sauna heater and sauna stones become extremely hot.
For your own safety, consult your supplier in the event of problems
that are not described in sucient detail in the user instructions.
Accessories Item number
Cut-o rocker switch SFE-350400 / 1-045-583
Instructions for installation and use p. 10/28
3. Product description
3.1. Scope of delivery
Sauna heater
Instructions for installation and use
3.2. Accessories
3.3. Product features
Finnish sauna mode: usually 80 to 100 °C; approx. 10% rel. humidity
Combi mode (only in combination with a combi control): approx. 40 to 65 °C,
35% to 70% humidity. The maximum permissible relative humidity decreases
with increasing temperature.
4. Installation and connection
Take the following points into account when positioning and connecting the sauna
heater:
The electrical connection may only be performed by a qualied electrician or
similarly qualied person.
A fully disconnecting all-pole isolating device compliant with overvoltage
category III must be tted on site.
The Home n sauna heater is a wall-mounted heater. Before starting the
heater, check that the heater has been rmly installed on the mounting rail.
WARNING!
Danger of electric shock
The sauna heater may only be installed and connected when the pow-
er supply is disconnected.
min 900
min 40
390
150
min 130
530
379
20
100
50
EN
Installation instructions, only for experts p. 11/28
4.1. Installation location and sensor position
Position the heater centrally in front of the air intake opening on the cabin wall.
Observe the safety distances to the cabin wall specied in Fig. 1.
Install the temperature sensor with excess temperature cut-out to the cabin wall
above the centre of the sauna heater. Maintain a distance of 15 cm to the sauna
cabin roof. Observe the assembly instructions for the sauna control unit.
4.2. Safety distances
Observe the minimum safety distances specied in Fig. 1.
Fig. 1 Safety distances
Home combi 6.0 kW and 9.0 kW
(HOME-C60 / HOME-C90)
Dimensions in mm
405
Installation instructions, only for experts p. 12/28
4.3. Installation on the cabin wall
Observe Fig. 1, Fig. 2, Fig. 3 and Fig. 4 (page 11, 12, 13).
1. Attach the mounting rail 1 to the wall horizontally using the wood screws
supplied 2. Observe the minimum distances for the heater shown in Fig. 1.
2. Suspend the heater 3 from the mounting rail from above, moving it down-
wards. Make sure that the heater is ush with the wall.
3. Secure the heater 3 using the lock screws supplied 4 on the mounting
rail 1.
Fig. 2 Mounting rail for Home combi
Dimensions in mm
WARNING!
Risk of re
To x the heater in place and secure it against slippage, use the sup-
plied lock screw 4 for attachment.
160 160
360
320
8
18
EN
Installation instructions, only for experts p. 13/28
POSITION OF THE MOUNTING RAIL
27,5
15
15
Fig. 3 Position of mounting rail for Home combi
Dimensions in mm
Fig. 4 Securing the Home combi (mounting rail)
1
3
4
1
3
Installation instructions, only for experts p. 14/28
4.4. Connection diagram for 400 V 3 N~
Fig. 5
2
4
5
1
Connection diagram for 400 V 3 N~
Home combi 6.0 kW and 9.0 kW
(HOME-C60 / HOME-C90)
1 Sauna control unit
2 Temperature sensor with excess temperature cut-out
3 Evaporator 2.0 kW
4 6.0 kW or 9.0 kW Heating system
5 Power supply
EN
Installation instructions, only for experts p. 15/28
4.5. Connection diagram for 230 V 1 N~
*
Fig. 6 Connection diagram for 230 V 1 N~
Home combi 6.0 kW and 9.0 kW
(HOME-C60 / HOME-C90)
2
4
5
1
*
1 Sauna control unit
2 Temperature sensor with excess temperature cut-out
3 Evaporator 2.0 kW
4 Heating system 6.0 kW or 9.0 kW
5 Power supply
Remove the copper bridge
3
Installation instructions, only for experts p. 16/28
HOME-C90
9.0 kW
4.6. Wiring diagrams
HOME-C60
6.0 kW
U V W N
W
2,0kW
2,0kW
2,0kW
N
V
N
U
to the control unit
U V W N
W
3,0kW
3,0kW
3,0kW
N
V
N
U
to the control unit
4.7. Electrical connection
1. Unscrew the screws 2 with a screwdriver.
2. Remove the cover plate 1.
3. Unscrew the screws 4 with a screwdriver.
4. Remove the cover plate 3.
1
32
4
EN
Installation instructions, only for experts p. 17/28
Connecting the Home combi 6.0 kW and 9.0 kW
(HOME-C60 / HOME-C90)
1. Guide the connection cable for the heating system through the feed-through 6.
2. Connect the wires of the connection cable (depending on the type) to the
matching terminals of the connector block 5 and to the appropriate sauna
control unit terminals. Observe the installation instructions for the sauna
control and the connection diagrams on page 14 and 15.
1. Guide the connection cable for the evaporator through the feed-through 7.
2. Connect the connectors of the evaporator cable to the PE – N – U1 – Wm
terminals on the connector block 5 and to the applicable sauna control
unit terminals. Observe the installation instructions for the sauna control and
the connection diagrams on page 14 and 15.
3. Fasten the cover plates 3 and 1 back on the sauna heater.
76
5
5 Connection block for the heating system and the evaporator
6 Feed-through for the connection cable of the heating system
7 Feed-through for the evaporator cable
Instructions for use for the user p. 18/28
5. Commissioning
5.1. Filling the stone container
The amount of stones suited to your heater can be found in
chapter Technical data (see page 27).
1. Wash the stones thoroughly using water and a brush before use.
Do not use any cleaning additives.
2. Before lling the heater with the sauna stones, check them for foreign objects
and remove any remaining packaging.
3. Place the stones in the stone container and also between the heating rods.
Stack the sauna stones loosely so that air can ow through the gaps.
4. Do NOT allow the heating rods to make contact with one another.
5. Make sure that the sauna stones do not protrude beyond the edge of
the stone container.
WARNING!
Risk of re due to overheating
If the sauna heater is used without sauna stones, the cabin walls will
become extremely hot. This could cause res.
NEVER operate the sauna heater without the sauna stones.
The stone basket 1 can be mounted at
two dierent heights.
Position 2: fewer stones, shorter heating
time, energy saving
Position 3 (set at factory): more stones,
larger amount of water for pouring possible,
creating more steam, longer heating times
1
3
2
EN
Instructions for use for the user p. 19/28
5.2. Heating for the rst time
CAUTION!
Formation of smoke and odours when heating up for the rst time
Materials used during the manufacturing process will be present on the
new heating elements. These evaporate when the sauna heater is heat-
ed up for the rst time. This produces smoke and an unpleasant odour.
Breathing in the fumes or smoke can be harmful to your health.
Perform the following steps when operating the sauna heater for the rst
time and if the heating elements for the sauna heater have been replaced.
This prevents damage to health due to the fumes and smoke produced when
heating for the rst time.
1. Heating the heating rods for the rst time
a. Select the highest possible temperature on the sauna control unit.
b. Heat up the sauna heater for half an hour.
Do NOT remain in the sauna cabin during this period.
2. Heating the evaporator for the rst time
a. Select a low temperature and high humidity on the sauna control unit.
b. Heat up the evaporator with half the amount of water
(see Filling the evaporator on page 20)
Do NOT remain in the sauna cabin during this period.
c. Switch o the sauna control unit after approx. 15 minutes.
d. Allow the evaporator to cool (for approx. half an hour).
e. Empty the water tank (see Filling the evaporator on page 20)
f. Repeat step 2.b.
g. Allow the sauna cabin to ventilate thoroughly after heating for
the rst time.
h. If no smoke or odours form the next time the sauna heater is heated,
you can start to use the sauna.
If smoke or odours form again, leave the sauna cabin immediately,
and repeat the initial heating process, followed by ventilation.
NOTE!
Overheat protector of the device can go o also at temperatures below -5˚C /
23˚F (storage, transport, environment). Before installation take the device to the
warm environment. The overheat protector can be reset when the temperature
of the device is approx 18˚C / 64˚F. The overheat protector must be reset be-
fore using the device.
Instructions for use for the user p. 20/28
WARNING!
Risk of re
Combustible objects that are placed on the heater will ignite and cause
res.
NEVER place combustible objects on the sauna heater.
Make sure that NO ammable objects have been placed on the heater
before operating it.
6. Operation
6.1. Operating the sauna heater
A sauna control unit is used to operate the sauna heater. For information on how
to operate the sauna control unit, read the operating instructions for the device
used. Please note that only sauna control units without a remote start function
are permitted for use with the Home combi sauna heater.
6.2. Finnish sauna mode
In Finnish sauna mode, only the heating system operates. Dry heat is produced.
The temperature in the cabin is high (80 to 100 °C). The maximum humidity level
of 10% is low. The temperature in the sauna cabin is regulated by your sauna
control unit.
At the end of the sauna session, you can pour an infusion of water over the stones.
Pour water over the stones using a sauna ladle. The water evaporates and
the humidity in the sauna cabin increases.
When pouring water over the stones, observe the following points:
Only use tap water. Sea water, hard water and chlorinated water can damage
the sauna heater.
Only use fragrances and essential oils that are suitable for use in saunas. Follow
the manufacturers instructions on the packaging of the scented substance.
Do not pour the water onto the stones too quickly. Only this way will all the
water evaporate completely.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212

Sentiotec Home combi Manuale utente

Tipo
Manuale utente