ADEMCO Vista-20PCN Manuale utente

Categoria
Sistemi di controllo accessi di sicurezza
Tipo
Manuale utente

Questo manuale è adatto anche per

K5309-1V1 8/01
1
9,67$39,67$3&1
9,67$39,67$3&1
6HFXULW\6\VWHPV
8
VHU
·
V
*
XLGH
®
Technical Manuals Online! - http://www.tech-man.com
– 2 –
IMPORTANT!
PROPER INTRUSION PROTECTION
For proper intrusion coverage, sensors should be located at
every possible
point of entry
to a home or commercial premises. This would include any
skylights that may be present, and the upper windows in a multi-level building.
In addition, we recommend that radio backup be used in a security system so
that alarm signals can still be sent to the Central Monitoring Station in the event
that the telephone lines are out of order (alarm signals are normally sent over
the phone lines).
EARLY WARNING FIRE DETECTION
Early warning fire detection is important in a home. Smoke and heat detectors
have played a key role in reducing fire deaths in the United States. With regard
to the number and placement of smoke/heat detectors, we subscribe to the
recommendations contained in the National Fire Protection Association's
National Fire Alarm Code (NFPA 72). These recommendations can be found on
page 43 of this manual.
$ERXW7KLV0DQXDO
This manual is a step-by-step guide that will acquaint you with the system's
features and benefits. It defines the components and their functions, describes
their operation, and provides clear step-by-step instructions for normal and
emergency procedures. Keep this manual in a convenient place so that you can
refer to it as necessary.
Technical Manuals Online! - http://www.tech-man.com
– 3 –
7DEOHRI&RQWHQW V
System Overview....................................................................................................................5
Introduction ..........................................................................................................................5
System Basics .......................................................................................................................5
About The Keypads................................................................................................................8
General Information.............................................................................................................8
Functions of the Keypads...................................................................................................10
Entry/Exit Delays .................................................................................................................12
Exit Delay............................................................................................................................12
Entry Delay.........................................................................................................................12
Exit Alarms.........................................................................................................................13
Checking For Open Zones..................................................................................................13
Using the [
] Key................................................................................................................13
Arming the System...............................................................................................................14
Stay Mode: Arms Perimeter Only, Entry Delay On.........................................................14
Night-Stay Mode: Arms Perimeter Only, Plus Selected Zones .......................................14
Instant Mode: Arms Perimeter Only, Entry Delay Off....................................................14
Away Mode: Arms Entire System, Entry Delay On.........................................................14
Arming Commands.............................................................................................................15
Single Button Arming ........................................................................................................16
Single-Button “Step” Arming.............................................................................................16
Using the Keyswitch............................................................................................................17
Using the Keyswitch...........................................................................................................17
Disarming and Silencing Alarms......................................................................................18
Using the [OFF] key...........................................................................................................18
Bypassing Protection Zones..............................................................................................19
Using the BYPASS Key......................................................................................................19
Quick Bypass ......................................................................................................................20
Chime Mode...........................................................................................................................20
Viewing Current Date and Time ......................................................................................21
Viewing the Current Date and Time.................................................................................21
Setting the Date and Time.................................................................................................21
Panic Keys..............................................................................................................................22
Using Panic Keys................................................................................................................22
Technical Manuals Online! - http://www.tech-man.com
– 4 –
7DEOHRI&RQWHQWV
Macro Key Programming & Usage...................................................................................23
About Macro Keys...............................................................................................................23
Example of Macro Programming.......................................................................................24
Using a Programmed Macro Key.......................................................................................24
Using Device Commands....................................................................................................25
Paging Feature .....................................................................................................................26
About Automatic Paging ....................................................................................................26
Single Button Paging..........................................................................................................27
Latch Key Paging ...............................................................................................................27
Security Codes & Authority Levels..................................................................................28
About Security Codes .........................................................................................................28
Authority Level Definitions ...............................................................................................28
To assign User Codes and Attributes................................................................................29
Accessing Other Partitions (GOTO Command and Multi-Partition Arming)......30
About Accessing Partitions................................................................................................30
Using the GoTo Command.................................................................................................31
Multi-Partition Arming......................................................................................................31
Common Zone Operation....................................................................................................32
Scheduling .............................................................................................................................33
About Scheduling................................................................................................................33
Creating Schedules.............................................................................................................33
Event Logging Procedures.................................................................................................35
About Event Logging..........................................................................................................35
Viewing the Event Log.......................................................................................................35
Testing the System (To Be Conducted Weekly)............................................................36
Trouble Conditions..............................................................................................................37
Maintaining Your System...................................................................................................40
Fire Alarm System (If Installed).......................................................................................41
Quick Guide to Basic System Functions ........................................................................45
Summary of Audible/Visual Notifications......................................................................46
Regulatory Statements and Warnings............................................................................48
Charts of Your System's Features....................................................................................50
Technical Manuals Online! - http://www.tech-man.com
– 5 –
6\VWHP2YHUYLHZ
,QWURGXFWLRQ
Congratulations on your ownership of an ADEMCO Security System. You've made a wise
decision in choosing it, for it represents the latest in security protection technology today,
and millions of premises are protected by ADEMCO systems. This system provides:
Three forms of protection: burglary, fire* and emergency
At least one keypad which provides control of system and displays system status
Various sensors for perimeter and interior burglary protection
Smoke or combustion detectors* designed to provide early warning in case of fire.
Your system may also have been programmed to automatically send alarm or status
messages over the phone lines to a Central Monitoring Station.
* Commercial installations and some residential systems may not include fire
protection – check with your installer.
NOTE: The features and procedures described in this manual apply to both the
VISTA-20P and VISTA-15P security systems. Differences are noted where applicable.
6\VWHP%DVLFV
Burglary Protection
Several modes of burglary protection: Stay, Night-Stay, Away, Instant, Maximum.
STAY: arms perimeter zones only and entry delay is on
INSTANT: same as STAY, except entry delay is off
NIGHT-STAY: arms perimeter zones and selected interior zones; entry delay on
AWAY: arms perimeter and all interior zones, entry delay is on
MAXIMUM: same as AWAY, except entry delay is off
You can BYPASS selected zones while leaving the rest of the system armed.
CHIME mode alerts you to the opening of protected doors and windows while the
system is disarmed.
Fire Protection
Fire protection is always active (if installed) and an alarm sounds if a fire
condition is detected
If necessary, you can manually initiate a fire alarm using the keypad (if
programmed).
Refer to the Fire Alarm System section for information regarding fire protection,
smoke detectors and planning emergency exit routes.
Security Codes
You were assigned a 4-digit security code during system installation.
Use your security code when arming and disarming the system, and when
performing other system functions.
Other users can be assigned different security codes, each with different
authority levels, which define the system functions a particular user can perform.
Technical Manuals Online! - http://www.tech-man.com
– 6 –
6\VWHP2YHUYLHZ
&RQWLQXHG
Zones and Partitions
The system sensing devices have been assigned to various “zones,” which are
specific areas of protection (e.g., front door, kitchen window, etc.).
Zone numbers are displayed at the keypad when an alarm or trouble condition
occurs on a sensor.
Partitions (VISTA-20P) provide two independent areas of protection, with each
partition containing a group of zones that can be armed and disarmed without
affecting other zones or users.
Partitioned systems (VISTA-20P) can include a common zone area, which is an
area shared by users of both partitions (such as a lobby in a building).
Arming, Step-Arming and Disarming Burglary Protection
The system must be armed before the burglary protection can sense intrusions.
To arm your system, enter your user code followed by the desired arming key.
If programmed, the [#] key can be pressed instead of entering the security code
when arming the system.
You can also use the step-arming key, if programmed, to arm the system, which
lets you use a function key to arm the system in one of three modes by simply
pressing the key repeatedly.
To disarm the system, enter your user code then press the [OFF] key.
Alarms
When an alarm occurs, both the keypad and external sounders will sound, and
the keypad will display the zone(s) causing the alarm.
If your system is connected to a Central Monitoring Station, an alarm message
will also be sent.
To stop the alarm sounding, simply disarm the system.
Memory of Alarm
When an alarm condition occurs, the keypad displays the number(s) of the
zone(s) that caused the problem, and displays the type of alarm.
The message remains displayed even after disarming the system, but can be
cleared with another “off” sequence.
Technical Manuals Online! - http://www.tech-man.com
– 7 –
6\VWHP2YHUYLHZ
&RQWLQXHG
Phone Access
If included, a phone module permits you to access the system via a touch-tone
phone, either on-premises or by call-in when away.
You can receive synthesized voice messages over the telephone regarding the
status of the security system.
You can arm and disarm the system and perform most function commands
remotely via the telephone, with voice confirmation provided after each command
entry.
Complete information regarding the use of this feature is provided in a separate
manual entitled “Phone Access User's Guide” that is supplied with the voice
module.
Paging Feature
If programmed, the system can automatically send certain system condition
messages to up to four (VISTA-20P) or two (VISTA-15P) pagers.
The display consists of code numbers that indicate the type of condition that has
occurred.
Function Keys
The “A”, “B”, “C”, and “D” keys on the keypad can be programmed to perform
various functions.
Functions include: activate a Panic alarm; arm the system; provide step arming;
switch lights on/off; send a message to a pager; display Time/Date; start a Macro
Scheduling
Your system can be programmed to automatically perform certain functions (e.g.,
arm the system) at a predetermined time each day.
Technical Manuals Online! - http://www.tech-man.com
– 8 –
$ERXW7KH.H\SDGV
*HQHUDO,QIRUPDWLRQ
Your keypads allow you to control all system functions. The keypads feature the
following:
A telephone style (digital) keypad
Liquid Crystal Display (LCD) which shows the nature and location of all
occurrences
Built-in sounder which will sound during alarms and troubles. The sounder also
"beeps" during certain system functions and when depressing any of the keys (to
acknowledge the key press).
Backlighting of the LCD display windows. Backlighting turns on when entering the
premises through any assigned entry/exit door, or when any key is pressed. This
feature is helpful when a keypad is located in a dimly lit area.
IMPORTANT:
If the keypad beeps rapidly upon entering the premises, it indicates
that an alarm has occurred during your absence and an intruder may still be on the
premises. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe
location.
There are two basic types of keypads which are functionally the same, but they have
different types of displays.
Alpha Display 2-line alpha display keypads feature a 2-line, 32-character
alphanumeric LCD which can display system messages in
friendly English. These keypads can also be programmed
with custom zone descriptors. To access the keys on the
keypad, simply open the swing-down door.
Fixed-Word Display Fixed-Word display keypads are functionally identical to
Alpha display keypads, but the LCD display uses pre-
designated words to identify the nature and location of
occurrences. To access the keys on the keypad, simply open
the swing-down door.
1
OFF
4
MAX
7
INSTANT
READY
2
AWAY
5
TEST
8
CODE
0
3
STAY
6
BYPASS
9
CHIME
#
ARMED
READY
1
OFF
4
MAX
7
INSTANT
READY
2
AWAY
5
TEST
8
CODE
0
3
STAY
6
BYPASS
9
CHIME
#
ARMED
READY
6160_kypd
6150 FIXED-WORD KEYPAD 6160 ALPHA KEYPAD
Technical Manuals Online! - http://www.tech-man.com
– 9 –
$ERXW7KH.H\SDGV&RQWLQXHG
)L[HG:RUG'LVSOD\.H\SDG
AWAY:
All burglary zones, interior and
perimeter, are armed.
STAY:
Perimeter burglary zones, such as
protected windows and doors, are
armed.
INSTANT:
Entry delay is turned off:
Lit with STAY = Instant mode
Lit with AWAY = Maximum mode
ALARM
FIRE
AWAY
BYPASS
STAY
CHECK INSTANT CANCELED
NIGHT NO AC
NOT READY
CHIME BAT
PHONE TEST
6150disp
TYPICAL FIXED-WORD DISPLAY
(6150 shown)
BYPASS:
This appears when one or more burglary protection zones have been
bypassed.
NOT READY:
Appears when burglary portion of the system is not ready for arming
(due to open protection zones). The system is ready to arm when this
message disappears and the READY indicator light comes on.
NO AC:
Appears when AC power has been cut off. System is operating on
backup battery power.
AC:
Appears when AC power is present.
CHIME:
Appears when the CHIME feature is activated.
BAT:
Low battery condition in a wireless sensor (if zone number displayed)
or low system battery (if no zone number displayed).
ALARM:
Appears when an intrusion has been detected and the system is armed
(also appears during a fire alarm or audible emergency alarm).
Accompanied by the protection zone in alarm.
CHECK:
Appears when a malfunction is discovered in the system at any time or
if an open is detected in a FIRE zone at any time or a fault in a
DAY/NIGHT burglary zone during a disarmed period. Accompanied by
a display of zone number in trouble.
FIRE
: Appears when a fire alarm is present. Accompanied by a display of the
zone in alarm.
A FIRE display also appears when a fire alarm is manually activated,
accompanied by a display of emergency key zone number programmed
for fire.
Technical Manuals Online! - http://www.tech-man.com
– 10 –
)XQFWLRQVRIWKH.H\SDGV
1.
DISPLAY WINDOW.
Alpha Display Keypads:
2-line, 32-
character Liquid Crystal Display (LCD)
keypads that display protection point
identification, system status, and messages.
Fixed-Word Display Keypads:
Display
protection zone ID and system status
messages using pre-designated words in the
LCD display.
2.
1
OFF
Disarms burglary portion of the
system, silences alarms and audible trouble
indicators, and clears visual display after
problem's correction.
3.
2
AWAY
Arms the entire burglary system,
perimeter and interior.
4.
3
STAY
Arms perimeter portion of burglary
system only. Interior protection is not armed,
allowing movement within premises without
causing an alarm.
5.
5
TEST
Tests the system and alarm
sounder if disarmed. Refer to Testing The
System section for test procedures.
6.
6
BYPASS
Removes individual protection
zones from being monitored by the system.
7.
8
CODE
Used to assign additional user
codes for other users of the system.
8.
9
CHIME
Turns CHIME mode on and off.
When on, the opening of windows or doors
while the system is disarmed will sound 3
beeps at the keypad(s).
9.
#
This key can be used for "Quick
Arming" of the system without use of a
security code (if programmed).
10.
KEYS 0–9:
Used to enter your security
code(s) and to perform their associated
system functions after the security code has
been entered.
11.
READY
Used to display all open protection
zones.
12.
7
INSTANT
Arms in manner similar to the
STAY mode, but without the entry delay
feature. Entering via an entry/exit door will
cause an alarm.
13.
4
MAXIMUM
Arms the entire burglary system,
perimeter and interior, but without entry
delay feature. Entering via an entry/exit door
will cause an alarm.
14.
FUNCTION KEYS:
Keys A, B, C, D may
have been programmed for a variety of
functions, including panic (emergency)
functions. For details, see the Function Keys
section.
15.
READY INDICATOR:
(GREEN) Lit when
the system is
ready to be armed (no faults
present). While the system is disarmed, this
indicator will go on and off as protection
zones are closed and opened.
16.
ARMED INDICATOR:
(RED) Lit when the
system has been armed.
17.
INTERNAL SOUNDER:
The built-in
sounder mimics the alarm sounder during
alarms, and will also "beep" during certain
system functions.
Technical Manuals Online! - http://www.tech-man.com
– 11 –
)XQFWLRQVRIWKH.H\SDGV&RQWLQXHG
1
OFF
4
MAX
7
INSTANT
READY
2
AWAY
5
TEST
8
CODE
0
3
STAY
6
BYPASS
#
ARMED
READY
V20P-001-V0
9
CHIME
3
2
4
6
8
9
10
14
11
16
15
17
12
5
7
1
13
(Keypads shown without swing-down front door)
IMPORTANT!
When entering codes and commands, sequential key depressions must be made
within 4-5 seconds of one another. If 4-5 seconds elapse without a key depression, the
entry will be aborted and must be repeated from its beginning. Be sure to observe
this precaution when performing any of the procedures in this manual.
If you make a mistake while entering a security code, stop, press the [
] key, and
then start over. If you stop in the middle while entering a code, and then
immediately start the entry over, an erroneous code might be entered.
Technical Manuals Online! - http://www.tech-man.com
– 12 –
(QWU\([LW' HOD\V
Your system has preset time delays, known as exit delay and entry delay.
([LW'HOD\
Exit delay gives you time to leave through the designated exit door without setting
off an alarm. Exit delay begins immediately after arming your system in any
arming mode and Alpha Display keypads display the message “You May Exit Now.”
When “You may exit now” disappears, the system is fully armed.
If programmed, a slow
beeping will sound during the exit delay period until the last 5 seconds, which then
changes to fast beeping (alerting you to the end of exit delay). If you cannot leave by
this time, you should stop, disarm the system, and start over to avoid a false alarm.
Exit Delay Restart.
If you wish to open the entry/exit door to let someone in after arming
STAY, you can re-start the
exit
delay at any time –
simply press the
[
]
key
, then let that
person in. The system automatically re-arms when exit delay expires, which avoids having to
disarm the system and then re-arm it again. In addition, when the system is armed AWAY,
re-entering the premises (e.g., forgot a wallet) through the entry/exit door before exit delay
time expires will reset the exit delay time.
(QWU\'HOD\
Entry Delays give you time to disarm the system when you re-enter through the
designated entrance door. You must disarm the system before the entry delay period
ends, or an alarm will occur. The keypad beeps during the entry delay period,
reminding you to disarm the system. There are two entry delays (if programmed). The
first is for your primary entrance and the second can be used for a secondary entrance,
where a longer delay is required to walk to the keypad to disarm the system.
You can also arm the system with no entry delay at all by using the INSTANT or
MAXIMUM arming mode. This mode provides greater security while on the
premises or while away for extended periods of time.
See your installer for your delay times.
Partition 1___________________________________________________________
Exit Delay:
seconds Entry Delay 1: seconds
Entry Delay 2:
seconds
NOTE:
Entry/Exit times set for partition 1 also apply to the common zone (VISTA-20P).
Partition 2 (VISTA-20P)______________________________________________
Exit Delay:
seconds Entry Delay 1: seconds
Entry Delay 2:
seconds
Technical Manuals Online! - http://www.tech-man.com
– 13 –
(QWU\([LW'HOD\V
&RQWLQXHG
([LW$ODUPV
Whenever you arm the system, the exit delay begins. If an entry/exit door or interior
zone is faulted when the exit delay ends (e.g., exit door left open), the system sounds
an alarm and starts the entry delay timer. If you disarm the system before the entry
delay ends, the alarm sound stops and the message "CANCELED ALARM" or "CA" is
displayed on the keypad, along with a zone number indicating the faulted zone. No
message is sent to the Central Monitoring Station.
To clear the exit alarm condition, the open zone must be made intact; to clear the
display, enter your code plus OFF.
If you do not disarm the system before the entry delay ends, and an entry/exit door or
interior zone is still open, the alarm sound continues and an "exit alarm" message is
sent to the Central Monitoring Station. The message ""EXIT ALARM" or "EA" is
displayed on the keypad, along with a zone number indicating the faulted zone. To
stop the alarm, the system must be disarmed (your code plus OFF); to clear the
display, enter your code plus OFF a second time.
An “exit alarm” also results if an entry/exit door or interior zone is faulted within two
minutes after the end of the exit delay.
Your system may have been programmed for this feature to minimize false alarms sent to the Central
Monitoring Station. Ask your installer if "Exit Alarm" is active in your system. If so, check this box.
&KHFNLQJ)RU2SHQ=RQHV
8VLQJWKH>@.H\
B
efore arming your system, all protected doors, windows and other protection zones
must be closed or bypassed, otherwise the keypad will display a "Not Ready"
message.
Use the READY
key to display all faulted zones, making it easier for you to identify
and secure any open zone.
1. Press [
] (do not enter code first) to display faulted
zones
.
2. Secure or bypass the zones displayed.
3.
The keypad’s READY indicator lights when all
protection zones have been either closed or bypassed.
4. Arm the system as desired.
Alpha Display:
Fixed-Word Display:
Zone no. and “NOT READY”
Technical Manuals Online! - http://www.tech-man.com
– 14 –
$UPLQJWKH6\VWHP
6WD\0RGH$UPV3HULPH WHU2QO\(QWU\'HOD\2Q
Used when you want to arm the system with persons staying inside (or if you have
pets that are moving throughout the premises).
The perimeter sensors are armed, but interior sensors are left disarmed.
Exit delay begins (you can leave through the entry/exit door, if desired).
An alarm sounds if any protected window or non-entry/exit door is opened.
You may otherwise move freely within the premises.
Persons entering later can enter through an entry/exit door, but they must disarm
the system within the entry delay period to avoid sounding an alarm.
1LJKW6WD\0RGH$UPV3HULPH WHU2Q O\3OX V6HOHFWHG=RQHV
Use Night-Stay mode to provide increased security while staying inside.
Arms same as Stay mode, but also arms pre-selected interior sensors (programmed
by your installer), while other interior sensors are left disarmed.
Persons entering later can use an entry/exit door but must not violate any of the
programmed interior zones to avoid sounding an alarm.
IMPORTANT: When Night-Stay mode is on, the selected interior zones are armed and cause an
alarm if anyone enters those areas (e.g., waking in the middle of the night). To avoid sounding an
alarm, you must disarm the system before any activity takes place in those interior zones.
,QVWDQW0RGH$UPV3HULPHWHU2QO\(QWU\'HOD\2II
Used when staying inside and do not expect anyone to use an entry/exit door.
Arms same as Stay mode.
An alarm sounds immediately if any protected perimeter window or any door is
opened, including entry/exit doors.
IMPORTANT: Arming in this mode greatly increases the chance of false alarms. Use extreme
care in selecting this mode of arming.
$ZD\0RGH$UPV(QWLUH6\VWHP(QWU\'HOD\2Q
Used when nobody will be staying inside (including pets).
The entire system (interior and perimeter) is armed.
Exit delay begins letting you leave through the entry/exit door.
An alarm sounds if a protected window or any door is opened, or if any movement
is detected inside your premises.
You can reenter through an entry/exit door, but you must disarm the system within
the entry delay period to avoid sounding an alarm.
0D[LPXP0RGH$UPV(QWLUH6\VWHP( QWU\ 'HOD\2II
Used when leaving the premises for extended periods (e.g., vacation).
Arms same as Away mode, but entry delay is off.
An alarm sounds same as Away mode, and sounds upon opening entry/exit doors.
Technical Manuals Online! - http://www.tech-man.com
– 15 –
$UPLQJWKH6\VWHP
$UPLQJ& RP PD QGV
Before arming, close all perimeter doors and windows and make sure the Ready to Arm
message is displayed.
Mode Press these keys… Keypad Confirms By…
Stay security code + [3] (STAY)
three beeps
armed STAY message displayed
red ARMED indicator lights
Night-Stay security code + [3] + [3]
three beeps
NIGHT-STAY message displayed
red ARMED indicator lights
Instant security code + [7] (INSTANT)
three beeps
armed STAY message displayed
red ARMED indicator lights
Note that entry delay is turned off.
Away security code + [2] (AWAY)
two beeps, or, if programmed, beeping
for duration of exit delay
armed AWAY message displayed
red ARMED indicator lights
Leave the premises through an entry/exit
door during the exit delay period to avoid
causing an alarm. The keypad beeps
rapidly during the last 5 seconds of the
exit delay to warn you that it is ending.
Maximum security code + [4] (MAXIMUM)
same as Away (described above)
Note that entry delay is turned off.
Quick Arming
If "Quick Arming" was programmed by the installer, the
[#]
key can be pressed in
place of the security code when arming the system. However,
the security code
must always be used to disarm the system.
Function Key Arming
For any arming command, a function key may have also been programmed for your
system. If so, you can press and hold the appropriate function key for 2 seconds to arm
the system. See your installer for the designated functions (see
Single Button
Arming
section).
Refer to the
Accessing Other Partitions
section for information on multi-partiion
arming (VISTA-20P).
Technical Manuals Online! - http://www.tech-man.com
– 16 –
$UPLQJWKH6\VWHP
6LQJOH%XWWRQ$UPLQJ
The “A”, “B”, “C”, and/or “D” keys on your keypad may have been programmed for
single-button arming. Note that while it will not be necessary to use a security code
for arming, a security code must always be used to disarm the system.
If Single-Button Arming is programmed:
A function key has been assigned to a specific type of arming: STAY mode,
Night-STAY mode, AWAY mode, or STEP-ARMING (see Step-Arming
paragraph).
You DO NOT need to enter your user code before pressing the function key
(you always need your user code to DISARM the system).
Before arming, close all perimeter doors and windows.
1.
Press and hold the assigned function key for 2
seconds (no code is required). Function keys are
shown below.
321
654
987
#0
*
READY
INSTANT
OFF
CODE
AWAY
TEST
CHECK
STAY
BYPASS
A
B
C
D
ADT3000-007-V0
Alpha Display:
Fixed-Word Display:
Green LED lit
2.
The keypad begins beeping and displays the armed
message. The red ARMED indicator also lights.
Alpha Display:
Fixed-Word Display:
AWAY
6WHS$UPL QJ )H DWXUH
Single-Button “Step” arming may have been programmed into one of the lettered keys
(A, B, C, or D). Check with your installer to see if this has been done in your system.
If Step-Arming is programmed:
The assigned key provides a choice of three levels of security.
The selected key can be pressed once, twice, or three times, increasing the level
of security with each press, as follows
Key
Ø
First Press
Ø
Second Press
Ø
Third Press
Ø
A, B, C, D
Armed-STAY Armed Night-STAY
(if programmed)
Armed-AWAY
Technical Manuals Online! - http://www.tech-man.com
– 17 –
8VLQJWKH.H\VZLWFK
8VLQJWKH.H\VZLWFK
Your system may be equipped with a keyswitch for use when arming and disarming.
Red and green lights on the keyswitch plate indicate the status of your system as
follows:
Green Light: Lights when the system is disarmed and ready to be armed (no
open zones). If the system is disarmed and the green light is off, it
indicates the system is not ready (one or more zones are open).
Red Light: Lights or flashes when system is armed in AWAY or STAY mode.
See your installer for the meanings of the lit red light:
Lit Steady = system armed AWAY or
system armed STAY and exit delay has expired
Flashing = system armed STAY and exit delay timer active
Rapid flashing = an alarm has occurred (memory of alarm).
Before arming, close all perimeter doors and windows.
To arm in the AWAY mode:
Turn the key to the right for 1/2 second and release.
Keypads beep twice and the red indicator lights or
flashes.
To arm in the STAY mode:
Turn the key to the right and hold for longer than 1
second, then release. Keypads beep three times and
the red indicator lights or flashes.
To disarm the system:
Turn the key to the right and release. The red light
turns off
GREEN
RED
Technical Manuals Online! - http://www.tech-man.com
– 18 –
'LVDUPLQJDQG6LOHQFLQJ$ODUPV
8VLQJW KH >2 )) @NH\
The OFF key is used to disarm the system, silence alarm and trouble sounds, and
clear alarm memories.
IMPORTANT
:
If you return and the main burglary sounder is on,
DO NOT ENTER, but
CONTACT THE POLICE from a nearby safe location.
If you return after an alarm has occurred and the main sounder has shut itself off,
the keypad will
beep rapidly upon your entering,
indicating that an alarm has occurred during your
absence.
LEAVE AT ONCE, and CONTACT THE POLICE from a nearby safe location.
1.
+ 1
(Security Code)
OFF
The “READY” indicator light will be lit if all zones
are secure, and the keypad will emit a single tone to
confirm that the system is disarmed.
Alpha Display:
Fixed-Word Display: READY
2.
To Silence a Burglary Alarm and Clear a Memory of Alarm
Enter your security code and press the OFF key to silence the alarm (or warning
tones of a Memory of Alarm).
Note the zone in alarm on the keypad display, and make that zone intact (close
door, window, etc.). Now enter the security code plus OFF sequence again to clear
the keypad’s Memory of Alarm display.
3.
To Silence a Fire Alarm and Clear Memory of Alarm
Simply press the OFF key to silence the alarm. Then enter the security code plus
OFF sequence to clear the keypad's Memory of Alarm display. See the Fire Alarm
System section.
Technical Manuals Online! - http://www.tech-man.com
– 19 –
%\SDVVLQJ3URWHFWLRQ=RQHV
8VLQJWKH%<3$66.H\
Use t
his key when you want to arm your system with one or more zones intentionally
unprotected. The system must be disarmed first.
Vent Zones:
Your system may have certain windows set as “vent” zones, which are
automatically bypassed if left open when arming the system (you do not need to
manually bypass them). However, if a vent zone window is closed
after
arming, it
becomes protected and will cause an alarm if opened again while the system is armed.
When bypassing zones:
The system must be disarmed before you can bypass zones.
Bypassed zones are unprotected and will not cause an alarm if violated.
The system will not allow fire zones to be bypassed.
Zones are automatically unbypassed when the system is disarmed.
1.
+ 6 + zone numbers (see below)
(Security Code)
BYPASS
Enter the 2-digit zone number(s) for the zone(s) to be
bypassed (e.g., 06, 10, 13, etc.). Single digit zone
numbers must be preceded by a zero (e.g. 05, 06).
Alpha Display:
Fixed-Word Display:
NOT READY
2.
When finished, the keypad will momentarily display
a "Bypass" message for each bypassed zone number.
Wait for all bypassed zones to be displayed.
Arm the system as usual. When armed, the arming
message is displayed with “ZONE BYPASSED.”
To display bypassed zones prior to arming, enter
your security code and press the [6] BYPASS key.
Alpha Display:
Fixed-Word Display:
BYPASS
Alpha Display:
Typical armed display after
bypassing zones.
Technical Manuals Online! - http://www.tech-man.com
– 20 –
%\SDVVLQJ3URWHFWLRQ=RQHV
4XLFN%\S DVV
If programmed, "Quick Bypass" allows you to easily bypass all open (faulted) zones
without having to enter zone numbers individually. This feature is useful if, for
example, you routinely leave certain windows open when arming at night.
1.
+ 6 + [#]
(Security Code)
BYPASS
In a few moments, all open zones will be displayed
and automatically bypassed.
Make sure that only those
zones that you wish to leave unprotected are bypassed, and
that there are no other zones unintentionally left open.
Alpha Display:
Fixed-Word Display:
NOT READY
2.
Wait for all bypassed zones to be displayed, then arm
the system as desired.
Alpha Display:
Fixed-Word Display: BYPASS
Ask your installer if "Quick Bypass" is active for your system, and if so, check here:
&KLPH0RGH
CHIME mode alerts you to the opening of a perimeter door or window while the
system is disarmed.
When Chime mode is activated:
Three tones sound at the keypad whenever a perimeter door or window is opened.
Interior zones do not produce a tone when they are faulted.
Pressing the READY key will display the open protection points.
Chime mode can be used only while the system is disarmed.
To turn Chime Mode on:
+ 9
(Security Code)
CHIME
The CHIME message will appear. Perimeter zones
will cause a tone when faulted.
Alpha Display:
Fixed-Word Display:
READY
To turn Chime Mode off:
+ 9 again
(Security Code)
CHIME
The CHIME message will disappear.
Alpha Display:
Fixed-Word Display:
CHIME
Technical Manuals Online! - http://www.tech-man.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

ADEMCO Vista-20PCN Manuale utente

Categoria
Sistemi di controllo accessi di sicurezza
Tipo
Manuale utente
Questo manuale è adatto anche per

in altre lingue