ProLights Single source multipurpose LED PAR available in TU, DY and UV version Manuale utente

Categoria
Proiettori
Tipo
Manuale utente
EN - IT
USER MANUAL
MANUALE UTENTE
ECLPAR
SINGLE SOURCE MULTIPURPOSE LED PAR
All rights reserved by Music & Lights S.r.l. No part of this instruction manual may be
reproduced in any form or by any means for any commercial use.
In order to improve the quality of products, Music&Lights S.r.l. reserves the right to modify the
characteristics stated in this instruction manual at any time and without prior notice.
All revisions and updates are available in the ‘manuals section on site www.musiclights.it
REV. 01-02/19
1
ECLPARTU-DY-UV
Packing content
ECLPARTU-DY-UV
User manual
Power cable
Additional optics: 24° (on board - for TU and DY
versions), 12° and 65° lens included (for TU and DY
versions); 40° lens optional (for TU and DY versions)
- gel frame holder included (for TU and DY versions),
egg crate optional
Other: for the UV version only the 40 ° lens is included.
No other optics or accessories are available and
should not be mounted for this version
TABLE OF
CONTENTS
Safety
General instructionsGeneral instructions
Warnings and installation precautionsWarnings and installation precautions
1 Introduction
1. 1 Description and specications1. 1 Description and specications
1. 2 Operating elements and connections1. 2 Operating elements and connections
2 Installation
2. 1 Mounting2. 1 Mounting
3 Functions and settings
3. 1 Operation3. 1 Operation
3. 2 Basic3. 2 Basic
3. 3 Menu structure3. 3 Menu structure
3. 4 DMX mode3. 4 DMX mode
3. 5 DMX conguration3. 5 DMX conguration
3. 6 Setting3. 6 Setting
3. 7 Channels DMX3. 7 Channels DMX
3. 8 Fixture settings3. 8 Fixture settings
Led frequency Led frequency
Factory Reload Factory Reload
3. 9 Fixture Information3. 9 Fixture Information
3. 10 Operations in automatic mode3. 10 Operations in automatic mode
Master/Slave Master/Slave
Eects Eects
4 Maintenance
4. 1 Maintenance and cleaning the unit4. 1 Maintenance and cleaning the unit
4. 2 Trouble shooting4. 2 Trouble shooting
2
2
3
5
8
9
9
10
11
11
11
12
13
13
13
13
13
13
13
15
15
2
ECLPARTU-DY-UV
SAFETY
General instruction
The products referred to in this manual conform to the European Community Directives and are there-
fore marked with .
The unit is supplied with hazardous network voltage (230V~). Leave servicing to skilled personnel only.
Never make any modications on the unit not described in this instruction manual, otherwise you will
risk an electric shock.
Connection must be made to a power supply system tted with ecient earthing (Class I appliance ac-
cording to standard EN 60598-1). It is, moreover, recommended to protect the supply lines of the units
from indirect contact and/or shorting to earth by using appropriately sized residual current devices.
The connection to the main network of electric distribution must be carried out by a qualied electrical
installer. Check that the main frequency and voltage correspond to those for which the unit is designed
as given on the electrical data label.
This unit is not for home use, only professional applications.
Never use the xture under the following conditions:
- in places subject to vibrations or bumps;
- in places with a temperature of over 45 °C.
Make certain that no inammable liquids, water or metal objects enter the xture.
Do not dismantle or modify the xture.
All work must always be carried out by qualied technical personnel. Contact the nearest sales point for
an inspection or contact the manufacturer directly.
If the unit is to be put out of operation denitively, take it to a local recycling
plant for a disposal which is not harmful to the environment.
Warnings and installation precautions
If this device will be operated in any way dierent to the one described in this manual, it may suer
damage and the guarantee becomes void. Furthermore, any other operation may lead to dangers like
short circuit, burns, electric shock, etc.
Before starting any maintenance work or cleaning the projector, cut o power from the main supply.
Always additionally secure the projector with the safety rope. When carrying out any work, always com-
ply scrupulously with all the regulations (particularly regarding safety) currently in force in the country
in which the xture’s being used.
Install the xture in a well ventilated place.
Keep any inammable material at a safe distance from the xture.
Shields, lenses or ultraviolet screens shall be changed if they have become damaged to such an extent
that their eectiveness is impaired.
The lamp (LED) shall be changed if it has become damaged or thermally deformed.
Never look directly at the light beam. Please note that fast changes in lighting, e. g. ashing light, may
trigger epileptic seizures in photosensitive persons or persons with epilepsy.
Do not touch the product’s housing when operating because it may be very hot.
This product was designed and built strictly for the use indicated in this documentation. Any other use,
not expressly indicated here, could compromise the good condition/operation of the product and/or
be a source of danger.
We decline any liability deriving from improper use of the product.
WARNING! Before carrying out any operations with the unit, carefully read this instruction
manual and keep it with cure for future reference. It contains important information about
the installation, usage and maintenance of the unit.
3
ECLPARTU-DY-UV
- 1 - INTRODUCTION
1.1 ECLPARTU-DY-UV - DESCRIPTION AND TECHNICAL SPECIFICATIONS
EclipsePAR is a range of multipurpose LED xtures with a single source, delivering silent operation, high
quality of light and optical exibility, designed to redene the standard for theatrical, TVs and corporate
applications.
EclipsePARTU and DY features a 177W white LED source (3200K TU; 6000K DY) delivering a tremendous
lumen output and superior light quality with CRI and R9 > of 95.
EclipsePARUV is a real UV LED luminaire with a 365nm wavelength LED source.
The xture oers an extensive accessory range including barn doors, lter frame, egg crate and a multi-
tude of interchangeable lenses.
EclipsePAR features a smooth 16bit dimming as well as RDM control and adjustable PWM to look good in
front of a camera.
LIGHT SOURCE
Source: 177 W white LED / 108W UV LED
CT: (TU) 3200K - (DY) 6000K
CRI: > 96 for TU and DY versions
R9: > 95 for TU and DY versions
Luminous ux: (TU) 12°: 13526 lm - 24°: 13638 lm - 65°: 12376 lm; (DY) 12°: 13571 lm - 24°: 13453 lm -
65°: 12247 lm; (UV) 229.07lm
Lux: (TU) 12°: 15200 lux - 24°: 6560 lux - 65°: 1220 lux; (DY) 12°: 16500 lux - 24°: 6860 lux - 65°: 1230 lux;
(UV) 15.9lux @3m
Lux: (TU) 12°: 5472 lux - 24°: 2361.6 lux - 65°: 439.2 lux; (DY) 12°: 5940 lux - 24°: 2469.9 lux - 65°: 442.8
lux; (UV) 5.724lux @5m
Source life expectancy: >70.000 h
Other: >85 TLCI, 90/99 TM30 for TU and DY; 365nm for UV LED
OPTICS
Beam angle: 10° / 23° / 69° with dierent lens included°
Field angle: 27° / 40° / 97° with dierent lens included°
Lens diameter: (24°) 162.5 - (65°) 163mm
Lens type: fresnel lens
Additional optics: 24° (on board - for TU and DY versions), 12° and 65° lens included (for TU and DY ver-
sions); 40° lens optional (for TU and DY versions) - gel frame holder included (for TU and DY versions),
egg crate optional
Other: 40° lens only included on board in UV version; no other lens or accessories availables for UV
version
DYNAMIC EFFECTS
Static colour mode: selection of static colour
Manual colour mode: manual adjustment of dimmer and strobe
Auto mode: built-in programs with execution speed adjustment
BODY
Body: aluminiumdie-casting
Body colour: black
4
ECLPARTU-DY-UV
Fig.1 - Technical drawingECLPARTU-DY-UV
CONTROL
Protocols: DMX512, RDM
DMX channels: 1 / 2 / 3 / 6channel
RDM: RDM ready for xture remote monitor and settings
Display: OLED display
Firmware upgrade: yes, via USB-DMX interface (UPBOX1) not included
Master/Slave: for synchronized operation of more units linked in a chain
ELECTRONICS
Dimmer: linear 0~100% electronic dimmer
Dimmer curves: dierent dimming curves available
Strobe / shutter: 0 - 30 Hz, electronic
Operating temperature: -10° ~ +45°
Flicker: icker free operation
Selectable PWM: 600~25K Hz
ELECTRICAL
Power consumption: (TU, DY) 207 W - (UV) 107 W
Power supply: 100-240V – 50/60Hz
Power consumption (at 230V): (TU, DY) 207 W - (UV) 127W
Power consumption (at 120V): (TU, DY) 211 W - (UV) 134W
Output (at 230V): (TU, DY) 12 - (UV) 16 pcs units on a single power line
Output (at 120V): (TU, DY) 6 - (UV) 8 units on a single power line
Power factor: pF 0.99 @ 120V - pF 0.94 @ 230V
PHYSICAL
Cooling: forced air with low noise fan
Sospension and xing: any position with quick-lock omega brackets
Signal connection: Amphenol XLR 3p + 5p IN/OUT connectors
Power connection: Neutrik powerCON IN/OUT connectors
IP rating: 20
Dimensions (WxHxD): 316x318x404mm
Weight: 5.5kg
316mm/12,44in 318mm/12,52in
404mm/15,91in
ECLPARTU-DY-UV
11
3
2
8
10
9
5
6
7
4
Fig.2
5
ECLPARTU-DY-UV
1.2 OPERATING ELEMENTS AND CONNECTIONS
1. LOCKING KNOB for mounting bracket.
2. MOUNTING BRACKET.
3. CONTROL PANEL with display and 4 button
used to access the control panel functions
and manage them.
4. DMX IN (3-pole XLR): 1 = ground, 2 = DMX -,
3 = DMX +.
5. DMX OUT (3-pole XLR): 1= ground, 2 = DMX
-, 3 = DMX +.
6. DMX IN (5-pole XLR): 1 = ground, 2 = DMX-, 3
= DMX+, 4 N/C, 5 N/C.
7. DMX OUT (5-pole XLR): 1 = ground, 2 = DMX-,
3 = DMX+, 4 N/C, 5 N/C.
8. POWER IN (PowerCON IN): for connection to a
socket (100-240V~/50-60Hz) via the supplied
mains cable.
9. MAIN FUSE HOLDER: replace a burnt-out fuse
by one of the same type only.
10. POWER OUT (PowerCON OUT): power output
for connection of multiple units in series.
Fig.3
6
ECLPARTU-DY-UV
- 2 - INSTALLATION
2.1 MOUNTING
ECLPARTU-DY-UV may be set up on a solid and even surface. The unit can also be mounted upside down
to a cross arm. For xing, stable mounting clips are required. The mounting place must be of sucient
stability and be able to support a weight of 10 times of the units weight.
When carrying out any installation, always comply scrupulously with all the regulations (particularly re-
garding safety) currently in force in the country in which the xture’s being used.
Install the projector at a suitable location by means of the mounting bracket .
Always additionally secure the projector with the safety rope from falling down. For this purpose, fas-
ten the safety rope at a suitable position so that the maximum fall of the projector will be 20 cm.
Adjust the projector and use the knob to slightly release or tighten the locking mechanism of the
bracket if is necessary .
NOTE - For the installation of the projector ECLPARTU-DY-UV insert the hook to stare it to a suspended
system.
MENU UP DOWN ENTER
Used to access the menu or
to return a previous menu
option
Navigates downwards through
the menu list and increases
the numeric value when in a
function
Navigates upwards through
the menu list and decreases
the numeric value when in
a function
Used to select and store the
current menu or conrm the
current function value or
option within a menu
7
ECLPARTU-DY-UV
- 3 - FUNCTIONS AND SETTINGS
3.1 OPERATION
To turn on the ECLPARTU-DY-UV connect the supplied main cable to a socket (100-240 VAC-50/60 Hz).
Then the unit is ready for operation and can be operated via a DMX controller or it independently per-
forms its show program in succession.
To switch o, disconnect the mains plug from the socket. For a more convenient operation it is recom-
mended to connect the unit to a socket which can be switched on and o via a light switch.
It is the responsibility of the installer to ensure the electrical, mechanical and thermal compatibility of the
track system and the ttings. The connection to the main network of electric distribution must be carried
out by a qualied electrical installer.
ATTENTION - Make sure to remove the tension of feeding before beginning any intervention of mainte-
nance.
3.2 BASIC
Access control panel functions using the four panel buttons located directly underneath the LED Display
(g.4).
Fig.4- Functions of the buttons
MENU
1 CONNECT
ð
DMX Address
ð
Value (001-512)
DMX Mode
ð
1 Ch
2 Ch
3 Ch
6 Ch
2 SETUP
ð
Screen
ð
Back Light
ð
On
10S
20S
30S
Flip Display
ð
NO-Yes
Key Lock
ð
NO-Yes
3 ADVANCED
ð
Dimmer Mode
ð
O
Dimmer 1
Dimmer 2
Dimmer 3
Led Frequency
ð
600Hz
1200 Hz
2000 Hz
4000 Hz
6000Hz
25kHZ
Fan Mode
ð
Auto
On
O
Silent
Factory Reload
ð
NO-Yes
4 INFORMATION
ð
Fixture Hours
ð
0-9999
Version
ð
V1.0
UID
ð
15D0022****
5 STANDALONE
ð
Master/Slave
ð
Master/Slave
Eects
ð
Eect 1 Speed 1~100
Eect 2
Eect 3
Static
ð
Dimmer (000-255)
Strobe (000-255)
8
ECLPARTU-DY-UV
3.3 MENU STRUCTURE
Number
DMX
channels
Address of
start (example)
DMX address
occupied
Next possible start address
for unit No. 1
Next possible start address
for unit No. 2
Next possible start address
for unit No. 3
6 33 33 - 38 39 44 49
9
ECLPARTU-DY-UV
3.4 DMX MODE
Press the button MENU so many times until the display shows DMX ADDRESS, and press the button ENTER
to conrm.
Press UP/DOWN button to select the desired value (001-512). Press and hold to scroll quickly.
Press ENTER button to store.
Press the MENU button to go back or to meet the waiting time to exit the setup menu.
To able to operate the ECLPARTU-DY-UV with a light controller, adjust the DMX start address for the rst a
DMX channel. If e. g. address 33 on the controller is provided for controlling the function of the rst DMX
channel, adjust the start address 33 on the ECLPARTU-DY-UV. The other functions of the light eect panel
are then automatically assigned to the following addresses.
An example with the start address 33 is shown below:
3.5 DMX CONFIGURATION
ECLPARTU-DY-UV is equipped with dierent DMX conguration.
Press the button MENU so many times until shows DMX CHANNEL, and press the button ENTER to conrm.
Select the desired DMX conguration ( 1CH - 2CH - 3CH - 6CH ) through the buttons UP/DOWN.
3.6 SETTINGS
You can change the parameters for the device by following these steps:
SCREEN
You can change the following parameters related to the display, following the same procedure:
Press the MENU button to access the main menu.
Press the UP / DOWN keys to scroll the menu, select the Set Up icon, then press the ENTER button to
enter the next menu.
Press UP / DOWN to scroll through the menu, then select Screen, and press the ENTER button to enter
the next menu.
Press UP / DOWN to scroll through the menu, and then select one of the following settings for the dis-
play and press the ENTER key to display it.
- Back Light - Backlight display Auto O. This feature allows you to automatically turn o the backlight
after a specied time that you can set using the arrow buttons. To have the display always on select
On or choose another value to turn o the display after the amount of time you choose.
- Flip Display - Orientation of the display. This function allows you to rotate the display 180° to get a
better view of the display when the unit is hanging upside down. Select YES to activate or NO to dis-
able this function.
- Key Lock - With this function, you can lock the buttons on the control panel. If this functionis activat-
ed, the keys are automatically locked. To disable or temporarily disable the key lock function, press
the buttons in the following order to regain access to menu commands: UP, DOWN, UP, DOWN,
ENTER. Select ON to activate or OFF to disable
Press the ENTER button to conrm your choice.
Press the MENU button repeatedly to exit the menu and save changes.
1 CHANNEL
MODE
FUNCTION DMX
Value
1 Ch
1
DIMMER
0~100% 000 - 255
3 CHANNELS
MODE
FUNCTION DMX
Value
3 Ch
1
DIMMER
0~100% 000 - 255
2
DIMMER FINE
0~100% 000 - 255
3
STROBE
NO Function
Strobe Slow to Fast
000 - 010
011 - 255
6 CHANNELS
MODE
FUNCTION DMX
Value
6 Ch
1
DIMMER
0~100% 000 - 255
2
DIMMER FINE
0~100% 000 - 255
3
STROBE
NO Function
Strobe Slow to Fast
000 - 010
011 - 255
4
AUTO PROGRAMS
No Function
Auto Program 1
Auto Program 2
Auto Program 3
000 - 010
011 - 085
086 - 170
171 - 255
5
AUTO SPEED
Auto speed slow to fast 000 - 255
6
DIMMER SPEED MODE
Preset dimmer speed from display menu
Dimmer speed mode o
Dimmer speed mode1 (fast speed)
Dimmer speed mode2 (middle speed)
Dimmer speed mode3 (slow speed)
000 - 051
052 - 101
102 - 152
153 - 203
204 - 255
2 CHANNELS
MODE
FUNCTION DMX
Value
2 Ch
1
DIMMER
0~100% 000 - 255
2
STROBE
NO Function
Strobe Slow to Fast
000 - 010
011 - 255
10
ECLPARTU-DY-UV
3.7 CHANNELS DMX
11
ECLPARTU-DY-UV
3. 8 FIXTURE SETTINGS
It is possible to change the parameter value in the following way:
DIMMER
Enter in Dimmer mode to select specic dimming curve, press the button MENU so many times until
shows DIM MODE, and press the button ENTER to conrm.
Press the button UP/DOWN to select OFF - DIM1 - DIM2 - DIM3.
Press ENTER button to store.
Press the MENU button to go back or to meet the waiting time to exit the setup menu.
LED FREQUENCY
To adjust the frequency of the LEDs, press the MENU button repeatedly until the display shows LED
Frequency, and then press the ENTER button.
Select the frequency (600Hz - 1200Hz - 2000Hz - 4000Hz - 6000Hz - 25kHz) using the UP/DOWN buttons.
To conrm, press the ENTER key.
Press the MENU button to go back or wait a few seconds to exit the setup menu.
FAN MODE
Select this function to set the fans operation mode. Use the arrow buttons to select Auto, On, O, Silent.
Press the ENTER button to conrm your choice
FACTORY RELOAD
Select this function to reset the unit to the factory settings:
- To activate Reset Factory display press the button MENU so many times until shows Factory Reload, and
press the button ENTER to conrm.
Press ENTER button to conrm the selection.
Press the MENU button to go back or to meet the waiting time to exit from the setup menu automati-
cally.
3. 9 FIXTURE INFORMATION
To view all the information on the device, proceed as follows:
Press the MENU button to access the main menu.
Press the UP/DOWN button to scroll the menu, select the icon Information, then press the ENTER but-
ton to enter the next menu.
Press the UP/DOWN button to scroll through the menu, then select one of the following information
and press the ENTER button to display it.
- Fixture Hours - Through the Fixture Time function you can display the operating time of the projector.
- Software Version - Through Version function you can display the currently installed software version.
- UID - This option shows the RDM identication number
Press the MENU button repeatedly to exit the menu.
3. 10 OPERATIONS IN AUTOMATIC MODE
MASTER SLAVE
Press the UP/DOWN button to scroll through the menu, select Master/Slave and press ENTER to conrm your
choice.
Press the UP/DOWN button to select the mode of operation:
- Master, if the unit is connected in series with other units and it acts as the Master;
- Slave, if the unit is not connected to other units.
Press the ENTER button to conrm your choice.
12
ECLPARTU-DY-UV
EFFECTS
The unit independently runs through its show. Before you send an automatic program you need to set the
drive as Master/Alone:
Press the MENU button to access the main menu.
Press the UP/DOWN button to scroll the menu, select the Eects icon, then press the ENTER button to
enter the next menu.
Press the UP/DOWN button to select the mode of operation: Eects 1, Eects 2, Eects 3
Press the ENTER button to conrm your choice.
Press the MENU button repeatedly to exit the menu and save changes.
The unit will go into automatic mode by executing the program automatically.
13
ECLPARTU-DY-UV
- 4 - MAINTENANCE
4.1 MAINTENANCE AND CLEANING THE UNIT
Make sure the area below the installation place is free from unwanted persons during setup.
Switch o the unit, unplug the main cable and wait until the unit has cooled down.
All screws used for installing the device and any of its parts should be tightly fastened and should not
be corroded.
Housings, xations and installation spots (ceiling, trusses, suspensions) should be totally free from any
deformation.
The main cables must be in impeccable condition and should be replaced immediately even when a
small problem is detected.
It is recommended to clean the front at regular intervals, from impurities caused by dust, smoke, or
other particles to ensure that the light is radiated at maximum brightness. For cleaning, disconnect the
main plug from the socket. Use a soft, clean cloth moistened with a mild detergent. Then carefully wipe
the part dry. For cleaning other housing parts use only a soft, clean cloth. Never use a liquid, it might
penetrate the unit and cause damage to it.
4.2 TROUBLESHOOTING
Problems Possible causes Checks and remedies
Fixture does not light up
No mains supply
Dimmer fader set to 0
Faulty LED
Check the power supply voltage
Increase the value of the dimmer channels
Replace the LED board
General low light intensity
Dirty lens assembly
Misaligned lens assembly
Clean the xture regularly
Install lens assembly properly
Fixture does not power up
No power
Loose or damaged power cord
Check for power on power outlet
Check power cord
Contact an authorized service center in case of technical problems or not reported in the table can not be
resolved by the procedure given in the table.
Music & Lights S.r.l. si riserva ogni diritto di elaborazione in qualsiasi forma delle presenti istruzioni per l’uso.
La riproduzione - anche parziale - per propri scopi commerciali è vietata.
Al ne di migliorare la qualità dei prodotti, la Music&Lights S.r.l. si riserva la facoltà di modicare, in
qualunque momento e senza preavviso, le speciche menzionate nel presente manuale di istruzioni.
Tutte le revisioni e gli aggiornamenti sono disponibili nella sezione 'Manuali' sul sito www.musiclights.it
3
ECLPARTU-DY-UV
ECLPARTU-DY-UV
Manuale utente
Cavo di alimentazione
Ottiche aggiuntive: 24° (inclusa - per versioni TU e DY),
lenti 12° e 65° incluse (per versioni TU e DY); lente 40° op-
tional (per versioni TU e DY) - telaio porta gelatina inclu-
so (per versioni TU e DY), optional egg crate
Altro: per la versione UV è inclusa solo l'ottica a 40°.
Nessuna altra ottica o accessorio è disponibile e non deve
essere montata per questa versione
Contenuto dell'imballo:
INDICE
Sicurezza
Avvertenze generaliAvvertenze generali
Attenzioni e precauzioni per l’installazioneAttenzioni e precauzioni per l’installazione
1 Introduzione
1. 1 Descrizione e speciche tecniche1. 1 Descrizione e speciche tecniche
1. 2 Elementi di comando e di collegamento 1. 2 Elementi di comando e di collegamento
2 Installazione
2. 1 Montaggio2. 1 Montaggio
3 Funzioni e impostazioni
3. 1 Funzionamento3. 1 Funzionamento
3. 2 Impostazione base3. 2 Impostazione base
3. 3 Struttura menù3. 3 Struttura menù
3. 4 Modalità DMX3. 4 Modalità DMX
3. 5 Congurazione canali3. 5 Congurazione canali
3. 6 Impostazioni del proiettore3. 6 Impostazioni del proiettore
3. 7 Canali DMX3. 7 Canali DMX
3. 8 Funzioni del dispositivo3. 8 Funzioni del dispositivo
Frequenza led Frequenza led
Factory Reload Factory Reload
3. 9 Informazioni sul dispositivo3. 9 Informazioni sul dispositivo
3. 10 Modalità Automatica3. 10 Modalità Automatica
Master/Slave Master/Slave
Eects Eects
4 Manutenzione
4. 1 Manutenzione e pulizia del sistema ottico4. 1 Manutenzione e pulizia del sistema ottico
4. 2 Risoluzione dei problemi4. 2 Risoluzione dei problemi
4
4
5
7
8
9
9
10
11
11
12
13
13
13
13
13
14
14
14
15
15
4
ECLPARTU-DY-UV
ATTENZIONE! Prima di effettuare qualsiasi operazione con l’unità, leggere con attenzione
questo manuale e conservarlo accuratamente per riferimenti futuri. Contiene informazioni
importanti riguardo l’installazione, l’uso e la manutenzione dell’unità.
SICUREZZA
Avvertenze generali
I prodotti a cui questo manuale si riferisce sono conformi alle Direttive della Comunità Europea e per-
tanto recano la sigla
.
Il dispositivo funziona con pericolosa tensione di rete 230V~. Non intervenire mai al suo interno al di
fuori delle operazioni descritte nel presente manuale; esiste il pericolo di una scarica elettrica.
È obbligatorio eettuare il collegamento ad un impianto di alimentazione dotato di uneciente messa
a terra (apparecchio di Classe I secondo norma EN 60598-1). Si raccomanda, inoltre, di proteggere le
linee di alimentazione delle unità dai contatti indiretti e/o cortocircuiti verso massa tramite l’uso di
interruttori dierenziali opportunamente dimensionati.
Le operazioni di collegamento alla rete di distribuzione dell’energia elettrica devono essere eettuate
da un installatore elettrico qualicato. Vericare che frequenza e tensione della rete corrispondono alla
frequenza ed alla tensione per cui l’unità è predisposta, indicate sulla targhetta dei dati elettrici.
L’unità non per uso domestico, solo per uso professionale.
Evitare di utilizzare l’unità:
- in luoghi soggetti a vibrazioni, o a possibili urti;
- in luoghi a temperatura superiore ai 45°C.
Evitare che nell’unità penetrino liquidi inammabili, acqua o oggetti metallici.
Non smontare e non apportare modiche all’unità.
Tutti gli interventi devono essere sempre e solo eettuati da personale tecnico qualicato. Rivolgersi al
più vicino centro di assistenza tecnica autorizzato.
Se si desidera eliminare il dispositivo denitivamente, consegnarlo
per lo smaltimento ad unistituzione locale per il riciclaggio.
Attenzioni e precauzioni per l’installazione
Se il dispositivo dovesse trovarsi ad operare in condizioni dierenti da quelle descritte nel presente
manuale, potrebbero vericarsi dei danni; in tal caso la garanzia verrebbe a decadere. Inoltre, ogni altra
operazione potrebbe provocare cortocircuiti, incendi, scosse elettriche, rotture etc.
Prima di iniziare qualsiasi operazione di manutenzione o pulizia sull’unità togliere la tensione dalla rete
di alimentazione.
È assolutamente necessario proteggere l’unità per mezzo di una fune di sicurezza. Nell’eseguire qualsi-
asi intervento attenersi scrupolosamente a tutte le normative (in materia di sicurezza) vigenti nel paese
di utilizzo.
La distanza minima tra il proiettore e le pareti circostanti deve essere superiore a 50 cm e non devono
essere ostruite, in nessun caso, le aperture di aerazione.
Installare l’unità in un luogo ben ventilato.
Mantenere i materiali inammabili ad una distanza di sicurezza dall’unità.
La temperatura massima raggiungibile sulla supercie esterna dell’unità, in condizioni di regime termi-
co, è elevata. Dopo lo spegnimento, attendere 15 minuti per il rareddamento.
I ltri, le lenti o gli schermi ultravioletti se danneggiati possono limitare la loro ecienza.
I LED devono essere sostituiti se danneggiati o termicamente deformati.
Non guardare direttamente il fascio luminoso. Tenete presente che i veloci cambi di luce possono pro-
vocare attacchi d’epilessia presso persone fotosensibili o epilettiche.
Non toccare l’alloggiamento del prodotto quando è in funzione perché potrebbe essere molto caldo.
Questo prodotto è stato progettato e costruito esclusivamente per l’utilizzo indicato in questa docu-
mentazione. Qualsiasi altro utilizzo non espressamente indicato potrebbe pregiudicare la funzionalità
del prodotto e/o rappresentare fonte di pericolo.
Si declina qualsiasi responsabilità derivata dall’uso improprio del prodotto.
5
ECLPARTU-DY-UV
- 1 - INTRODUZIONE
1.1 ECLPARTU-DY-UV - DESCRIZIONE E SPECIFICHE TECNICHE
EclipsePAR is a range of multipurpose LED xtures with a single source, delivering silent operation, high
quality of light and optical exibility, designed to redene the standard for theatrical, TVs and corporate
applications.
EclipsePARTU and DY features a 177W white LED source (3200K TU; 6000K DY) delivering a tremendous
lumen output and superior light quality with CRI and R9 > of 95.
EclipsePARUV is a real UV LED luminaire with a 365nm wavelength LED source.
The xture oers an extensive accessory range including barn doors, lter frame, egg crate and a multitu-
de of interchangeable lenses.
EclipsePAR features a smooth 16bit dimming as well as RDM control and adjustable PWM to look good in
front of a camera.
SORGENTE LUMINOSA
Sorgente: 177 W white LED / 108W UV LED
CT: (TU) 3200K - (DY) 6000K
CRI: > 96 for TU and DY versions
R9: > 95 for TU and DY versions
Flusso luminoso: (TU) 12°: 13526 lm - 24°: 13638 lm - 65°: 12376 lm; (DY) 12°: 13571 lm - 24°: 13453 lm
- 65°: 12247 lm; (UV) 229.07lm
Lux: (TU) 12°: 15200 lux - 24°: 6560 lux - 65°: 1220 lux; (DY) 12°: 16500 lux - 24°: 6860 lux - 65°: 1230 lux;
(UV) 15.9lux @3m
Lux: (TU) 12°: 5472 lux - 24°: 2361.6 lux - 65°: 439.2 lux; (DY) 12°: 5940 lux - 24°: 2469.9 lux - 65°: 442.8
lux; (UV) 5.724lux @5m
Durata media sorgente: >70.000 h
Altro: >85 TLCI, 90/99 TM30 for TU and DY; 365nm for UV LED
OTTICA
Angolo di proiezione: 10° / 23° / 69° with dierent lens included°
Angolo di campo: 27° / 40° / 97° with dierent lens included°
Diametro: (24°) 162.5 - (65°) 163mm
Tipo lente: lente fresnel
Ottiche aggiuntive: 24° (on board - for TU and DY versions), 12° and 65° lens included (for TU and DY
versions); 40° lens optional (for TU and DY versions) - gel frame holder included (for TU and DY ver-
sions), egg crate optional
Altro: 40° lens only included on board in UV version; no other lens or accessories availables for UV
version
EFFETTI DINAMICI
Modalità colore statico: riproduzione statica di un colore
Modalità colore manuale: regolazione manuale dimmer e strobo
Auto mode: programmi integrati con regolazione della velocità di esecuzione
CORPO
Corpo: alluminio pressofuso
Colore: nero
6
ECLPARTU-DY-UV
CONTROLLO
Protocolli: DMX512, RDM
Canali DMX: 1 / 2 / 3 / 6channel
RDM: RDM ready per controllo e impostazioni remote della xture
Display: display OLED
Aggiornamento rmware: si, con interfaccia USB-DMX (UPBOX1) non inclusa
Master/Slave: per il controllo di più unità collegate in catena
ELETTRONICA
Dimmer: 0~100% lineare, elettronico
Curve dimmer: curve dimmer regolabili
Strobo / shutter: 0 - 30 Hz, elettronico
Temperatura d’esercizio: -10° ~ +45°
Flicker: funzionamento senza sfarfallio
PWM selezionabile: 600~25K Hz
ALIMENTAZIONE
Potenza assorbita: (TU, DY) 207 W - (UV) 107 W
Alimentazione elettrica: 100-240V – 50/60Hz
Potenza assorbita (a 230V): (TU, DY) 207 W - (UV) 127W
Potenza assorbita (a 120V): (TU, DY) 211 W - (UV) 134W
Output (a 230V): (TU, DY) 12 - (UV) 16 pcs unità connesse in serie
Output (a 120V): (TU, DY) 6 - (UV) 8 unità connesse in serie
Fattore di potenza: pF 0.99 @ 120V - pF 0.94 @ 230V
CARATTERISTICHE FISICHE
Rareddamento: aria ltrata forzata con ventole silenziate
Sospensione e ssaggio: qualsiasi posizione con supporti omega (inclusi) quicklock
Connessione di segnale: Amphenol XLR 3p + 5p IN/OUT connectors
Connessione di alimentazione: Neutrik powerCON IN/OUT connectors
Grado IP: 20
Dimensioni (LxAxP): 316x318x404mm
Peso: 5.5kg
Fig.1 - Technical drawing
ECLPARTU-DY-UV
316mm/12,44in 318mm/12,52in
404mm/15,91in
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

ProLights Single source multipurpose LED PAR available in TU, DY and UV version Manuale utente

Categoria
Proiettori
Tipo
Manuale utente