Lightolier PTS7-3 Manuale utente

Categoria
Luci di lavoro
Tipo
Manuale utente
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
"JSQPSU3PBE'BMM3JWFS."tt'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt
Lighting Systems PTS7-3
1BHFPG 1FSJNFUFS5SPVHI3FDFTTFE%JSFDU-PVWFSX"JS$IBOOFM-JHIU51FS'PPU4FDUJPO
#
Sample Run, End Plate and Corner Block Accessories
Quarter Scale
6
5
2
4
3
Complete ordering instructions on back.
Example of Straight Run
Lighted
Telescoping
Unit
84"
84"
60"
Example of Pattern Run
Telescoping
Unit
90° Inside Corner
48"
60"
48"
(3 places)
135° Outside
PTS7C1350 Standard
PTS7C1350A Air
8 -1/2” (245.11cm)
135° Inside
PTS7C1351 Standard
PTS7C1351A Air
90° Outside
PTS7C900 Standard
PTS7C900A Air
90° Inside
PTS7C901 Standard
PTS7C901A Air
End Cap Set
PTS7EP Standard
PTS7EPA Air
14” (35.56cm)
Features
1.
2. Lamping: One T8 or T12 fluorescent lamp, as specified. Provided by others.
3. Reflector: Die-formed semi-specular aluminum.
4. Louver: Semi-specular anodized aluminum, 40° lengthwise by 30° minimum
crosswise shielding. Supported along both edges by concealed frame of
extruded aluminum. Bold baffle, prismatic lens, gold anodized louver, open or
egg crate louver available, consult factory.
5. Socket Channels: Die-formed, pre-painted steel held by support brackets and
allows for up to 6” (15.24cm) lamp overlap.
6.
Electrical
Specify 120 volt or 277 volt. 3 conductor, 18 gauge wire. Color-coded quick
connectors allow ease of connection for joiner modules. For special circuiting,
consult factory. Factory installed ballast disconnect allows the ballast to be
disconnected from and reconnected to incoming power under load without turning
the entire circuit off.
Dimming: Advance Mark X, use Advance compatible two-wire control (no extra
control lead required).
7. Air Supply Channel: For air supply or ducted air return. Ducted air return
requires Anemostat #PRTS or equivelant (by others).
Mountings
Wall Adjustment Bracket - Allows for inconsistencies in wall straightness.
Die-formed steel used to mount system to the wall.
Finish
Ceiling trim painted baked enamel semi-gloss white.
Options and Accessories
90° inside, 90° outside, 135° inside, and 135° outside corerns available.
Labels
UL, cUL and I.B.E.W.
11-1/4” (28.58cm)
7 -1/16”
(19.94cm)
1-5/16” (3.33cm)
8-1/4” (20.96cm)
1-1/2” (3.81cm)
1-1/2”
(3.81cm)
4-3/4” (12.07cm)
1-1/2” (3.81cm)
Housing: Die-formed steel, slotted for air return. Integral flanges at each end
strengthen the housing and permit housings to be bolted together in continuous
runs and facilitate suspension of fixture. Concealed openings for heat extraction
and air return.
Ceiling Trim: Extruded aluminum with integral aligner splines.
90° Outside Corner
7
1
8' 1/2”
(245.11cm)
8' 1/2”
245.11cm
14" (35.56cm)
14" (35.56cm)
10' 2-1/4” (310.52cm)
9' 0” (274.32cm)
21' 10-3/4” (677.39cm)
Job Information Type:
"JSQPSU3PBE'BMM3JWFS."tt'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt
#
Lighting Systems PTS7-3
1BHFPG 1FSJNFUFS5SPVHI3FDFTTFE%JSFDU-PVWFSX"JS$IBOOFM-JHIU51FS'PPU4FDUJPO
Performance
85˚
75˚
65˚
45˚
55˚
0˚ 5˚ 15˚ 25˚ 35˚
600
750
450
900
050
300
CANDLEPOWER CURVE
29'3"-31'0" 1 3 1 1
30'3"-32'0" 1 4
31'3"-33'0" 1 3 1 1
32'3"-34'0" 1 4 1
33'3"-35'0" 1 4 1
34'3"-36'0" 1 4 1
35'3"-37'0" 1 4 1
36'3"-38'0" 1 4 1 1
37'3"-39'0" 1 5
38'3"-40'0" 1 4 1 1
39'3"-41'0" 1 5 1
40'3"-42'0" 1 5 1
41'3"-43'0" 1 5 1
42'3"-44'0" 1 5 1
43'3"-45'0" 1 5 1 1
44'3"-46'0" 1 6
45'3"-47'0" 1 5 1 1
46'3"-48'0" 1 6 1
47'3"-49'0" 1 6 1
48'3"-50'0" 1 6 1
49'3"-51'0" 1 6 1
50'3"-52'0" 1 6 1 1
51'3"-53'0" 1 7
52'3"-54'0" 1 6 1 1
REPORT NO: LRL 499-5D
LAMPS: 1-FO32T8
EFFICIENCY: 46.7%
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0565656 54 5454 525252
1504947 494846 474645
2454341 444240 434139
3413835 403735 393634
4373431 363331 353330
5333027 333027 322927
6302724 302724 292624
7282421 272421 272421
8252119 25 2119 242119
9231917 221917 221917
10 21 17 15 21 17 15 20 17 15
CANDLEPOWER SUMMARY
ZONE
Deg
0 45 90 135 180
180 00000
175 00000
165 00000
155 00000
145 00000
135 00000
125 00000
115 00000
105 00000
95 00000
90 00000
85 39 15 2 2 2
75 153 90 5 3 3
65 440 120 13 8 9
55 560 338 79 34 14
45 669 532 288 64 32
35 754 705 512 103 55
25 885 833 677 225 104
15 969 949 778 386 285
5 950 920 837 704 620
0 833 833 833 833 833
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARELAMP % LUMINAIRE
0-90 1354 46.7 100.0
90-180 0 0.0 0.0
0-180 1354 46.7 100.0
ROOM CAVITY RATIO
TWO SIDE MOUNTING
12 FT BETWEEN WALLS
1.5 76 76
2.5 50 50
3.5 41 41
4.5 38 92 73 65 73 92 38
5.5 37 37
6.5 35 35
7.5 34 72 71 69 71 72 34
8.5 33 33
9.5 32 63 66 65 66 63 32
024681012
DISTANCE FROM WALL, FEET RETURN AIR FLOW RATE, CFM
.01
20 30 40 60 80 100
.02
.03
.04
.06
.08
.10
AIR RETURN DATA
PRESSURE VS. AIR FLOW
HORIZONTAL FC
VERTICAL
STATIC PRESSURE, IN. W.G.
FC
0 deg
90
deg
180
deg
0 deg
90
deg
180
deg
NOTE: Add to end of catalog number for desired ballast.
Blank = T12 Magnetic 120v
2 =T12 Magnetic 277v
E1 = T12 Electronic 120v
E2 = T12 Electronic 227v
E81 = T8 Electronic 120v
E82 = T8 Electronic 227v
M71 = T8 Electronic Dimming Ballast 120v
M72 = T8 Electronic Dimming Ballast 277v
Ordering Instructions
Individual Fixtures:
1. Order number of FIXTURES.
2. Order one END PLATE SET per fixture.
Continuous Rows:
1. Determine run length.
2. Use chart above to find catalog numbers. Each run ends with a telescoping unit.
3. Order END PLATE SET for each open run.
Square/Rectangle Patterns:
1. Consult plans and mark locations for corners.
2. Calculate net footage of each run.
3. Deduct corner dimension from each corner.
4. Determine catalog numbers the same way as a straight run.
Quick Calculators
ONE SIDE MOUNTING
NO OPPOSITE WALL
1.5 63
2.5 33
3.5 22
4.5 18 76 51 33 23 18 15
5.5 16
6.5 15
7.5 14 51 45 35 28 23 19
8.5 12
9.5 12 40 38 33 27 23 20
024681012
DISTANCE FROM WALL, FEET
ONE SIDE MOUNTING
6 FT BETWEEN WALLS
1.5 72 39
2.5 43 45
3.5 33 45
4.5 28 85 68 43
5.5 26 40
6.5 24 37
7.5 22 60 55 33
8.5 21 30
9.5 19 49 48 28
0246
DISTANCE FROM WALL, FEET
DISTANCE FROM CEILING, FT
Ordering Information
ONE LIGHT
Cat No. PTS7T148A PTS7184A PTS7160A PTS7148A PTS7136A PTS7124A
Size 27" to 48" 84" 60" 48" 36" 24"
Lamps 1-4 Foot 2-4 Foot 2-3 Foot 1-4 Foot 1-3 Foot 1-2 Foot
Type Tele Module Module Module Module Module
4 '3"-6'0" 1 1
5'3"-7'0" 1 1
6'3"-8'0" 1 1
7'3"-9'0" 1 1
8'3"-10'0" 1 1 1
9'3"-11'0" 1 1
10'3"-12'0" 1 1 1
11'3"-13'0" 1 1 1
12'3"-14'0" 1 1 1
13'3"-15'0" 1 1 1
14'3"-16'0" 1 1 1
15'3"-17'0" 1 1 1 1
16'3"-18'0" 1 2
17'3"-19'0" 1 1 1 1
18'3"-20'0" 1 2 1
19'3"-21'0" 1 2 1
20'3"-22'0" 1 2 1
21'3"-23'0" 1 2 1
22'3"-24'0" 1 2 1 1
23'3"-25'0" 1 3
24'3"-26'0" 1 2 1 1
25'3"-27'0" 1 3 1
26'3"-28'0" 1 3 1
27'3"-29'0" 1 3 1
28'3"-30'0" 1 3 1
  • Page 1 1
  • Page 2 2

Lightolier PTS7-3 Manuale utente

Categoria
Luci di lavoro
Tipo
Manuale utente