Datalogic OM-GRYPHON Quick Reference Manual

Tipo
Quick Reference Manual
Datalogic Scanning, Inc.
959 Terry Street
Eugene, Oregon 97402
Telephone: (541) 683-5700
Fax: (541) 345-7140
An Unpublished Work - All rights reserved. No part of the contents of this documentation or the
procedures described therein may be reproduced or transmitted in any form or by any means without
prior written per-mission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" o
r
“Datalogic Scanning”). Owners of Datalogic products are hereby granted a non-exclusive, revocable
license to reproduce and transmit this documentation for the purchaser's own internal business purposes.
Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in this
documentation and shall ensure that all notices appear on any reproductions of the documentation.
Should future revisions of this manual be published, you can acquire printed versions by contacting you
r
Datalogic representative. Electronic versions may either be downloadable from the Datalogic website
(www.scanning.datalogic.com) or provided on appropriate media. If you visit our website and would like to
make comments or suggestions about this or other Datalogic publications, please let us know via the
"Contact Datalogic" page.
DISCLAIMER
Datalogic has taken reasonable measures to provide information in this manual that is complete and
accurate, however, Datalogic reserves the right to change any specification at any time without prio
r
notice. Datalogic is a registered trademark of Datalogic S.p.A. in many countries and the Datalogic logo is
a trademark of Datalogic S.p.A. all licensed to Datalogic Scanning, Inc. All other trademarks and trade
names referred to herein are property of their respective owners.
SERVICES AND SUPPORT
Datalogic provides several services as well as technical support through its website. Log on to
www.scanning.datalogic.com and click on the links
indicated for further information including:
PRODUCTS
Search through the links to arrive at your product page where you can download specific Manuals
and Software & Utilities including:
- Datalogic Aladdin™ a multi-platform utility program, which allows device configuration using
a PC. It provides RS232/USB-COM interface configuration as well as configuration barcode
printing.
SERVICES & SUPPORT
-
Datalogic Services - Warranty Extensions and Maintenance Agreements
- Authorised Repair Centres
CONTACT US
E-mail form and listing of Datalogic Subsidiaries
WARRANTY
Datalogic warranties this product against defects in workmanship and materials, for a period of 24 months
from the date of shipment, provided that the product is operated under normal and proper conditions.
Datalogic has the faculty to repair or replace the product; these provisions do not prolong the original
warranty term.
The warranty does not apply to any product that has been subject to misuse, accidental damage,
unauthorized repair or tampering.
Datalogic Scanning, Inc.
959 Terry Street
Eugene, OR 97402
07
dichiara che
declares that the
déclare que le
bescheinigt, daß das Gerät
declare que el
OM-GRYPHON, Base charger
e tutti i suoi modelli
and all its models
et tous ses modèles
und seine Modelle
y todos sus modelos
sono conformi alla Direttiva del Consiglio Europeo sottoelencata:
are in conformity with the requirements of the European Council Directive listed below:
sont conformes aux spécifications de la Directive de l'Union Européenne ci-dessous:
der nachstehenden angeführten Direktive des Europäischen Rats entsprechen:
cumple con los requisitos de la Directiva del Consejo Europeo, según la lista siguiente:
1999/5/EEC R&TTE
Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette déclaration repose sur la conformité des produits aux normes suivantes:
Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht:
Esta declaración se basa en el cumplimiento de los productos con las siguientes normas:
ETSI EN 301 489-3 v1.4.1,
AUGUST 2002:
E
LECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM
MATTERS (ERM); ELECTROMAGNETIC COMPATIBILITY (EMC)
STANDARD FOR RADIO EQUIPMENT AND SERVICES; PART 3:
S
PECIFIC CONDITIONS FOR SHORT-RANGE DEVICES (SRD)
OPERATING ON FREQUENCIES BETW EEN 9 KHZ AND 40 GHZ
ETSI EN 300 220-3 v1.1.1, S
EPTEMBER 2000:
E
LECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM
MATTERS (ERM); SHORT RANGE DEVICES (SRD); RADIO
EQUIPMENT TO BE USED IN THE
25 MHZ TO 1000 MHZ
FREQUENCY RANGE WITH POWER LEVELS RANGING UP TO
500
MW; PART 3: HARMONIZED EN COVERING ESSENTIAL
REQUIREMENTS UNDER ARTICLE
3.2 OF THE R&TTE
D
IRECTIVE
EN 60950-1, December 2001:
I
NFORMATION TECHNOLOGY EQUIPMENT SAFETY
P
ART 1: GENERAL REQUIREMENTS
March 1st, 2007
OM-Gryphon™
QUICK REFERENCE GUIDE
820001461en
g
(
Rev. C
)
9/07
UPDATES AND LANGUAGE AVAILABILITY
UK/US
The latest drivers and documentation updates for this product are available on
Internet.
Log on to: www.scanning.datalogic.com
I
Su Internet sono disponibili le versioni aggiornate di driver e documentazione di
questo prodotto. Questo manuale è disponibile anche nella versione italiana.
Collegarsi a: www.scanning.datalogic.com
F
Les versions mises à jour de drivers et documentation de ce produit sont
disponibles sur Internet. Ce manuel est aussi disponible en version française.
Cliquez sur : www.scanning.datalogic.com
D
Im Internet finden Sie die aktuellsten Versionen der Treiber und Dokumentation für
dieses Produkt. Die deutschsprachige Version dieses Handbuches ist auch
verfügbar.
Adresse : www.scanning.datalogic.com
E
En Internet están disponibles las versiones actualizadas de los drivers y
documentación de este producto. También está disponible la versión en español
de este manual.
Dirección Internet : www.scanning.datalogic.com
SYSTEM CONNECTIONS
CAUTION
Connections should always be made with power off!
Avoid touching the charging contacts since this may result in
reduced base station performance.
You can connect the OM-Gryphon™ cradle to the Host through the dedicated
connector, using the cable corresponding to the desired interface type.
CONNECTING AND DISCONNECTING THE INTERFACE CABLE
To connect the OM-Gryphon™:
1. Connect the OM-Gryphon™ to the appropriate interface cable, which must
be simply plugged into the Host connector on the base of the cradle.
2. Connect the cradle to an external power supply, see the figure below.
OM-Gryphon™ - Bottom View
To disconnect the cable, insert a paper clip or other similar object into the hole
corresponding to the Host connector on the body of the cradle. Push down on the clip
while unplugging the cable. Refer to the following figure:
OM-Gryphon™ - Disconnecting the Cable
COMPLIANCE
This device must be opened by qualified personnel only.
FCC COMPLIANCE
Modifications or changes to this equipment without the expressed written approval
of Datalogic could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference which
may cause undesired operation.
This device contains FCC ID U40015.
USB
RS232
WEDGE
PEN
OM-GRYPHON™ CONFIGURATION
Once you have performed system connection, you can configure the
OM-Gryphon™ cradle using the Gryphon™ M reader (the one paired to the cradle
with the Bind command). Select one of the interface codes according to you
r
application. For the Gryphon™ Mx30 configuration, refer to the “Gryphon™ Mx30
Quick Reference”.
POWER SUPPLY
This device is intended to be supplied by a UL Listed/CSA Certified Power Unit
marked "Class 2" or LPS power source rated 9-28 V DC, minimum 0.8 A which
supplies power directly to the cradle.
RADIO COMPLIANCE
Contact the competent authority responsible for the management of radio
frequency devices of your country to verify any possible restrictions or licenses
required.
Refer to the web site http://europa.eu.int/comm/enterprise/rtte/spectr.htm fo
r
further information.
WEEE COMPLIANCE
Host Interface Cable
Power Supply
DEFAULT VALUES
USB-KBD DEFAULT SETTINGS
USA keyboard, FIFO enabled, inter-character and inter-code delays disabled,
USB keyboard speed normal.
DATA FORMAT: code identifier disabled, code length not transmitted, no header,
terminator = ENTER, character replacement disabled, address stamping
disabled, address delimiter disabled.
RS232 Standard DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, inter-character delay
disabled, rx timeout 5 sec., ACK/NACK disabled, FIFO enabled, serial trigger lock
disabled.
DATA FORMAT: code identifier disabled, code length not transmitted, no header,
terminator = CR-LF, character replacement disabled, address stamping
disabled, address delimiter disabled.
WEDGE DEFAULT SETTINGS
USA keyboard, caps lock off, caps lock auto-recognition enabled, num lock
unchanged, inter-character and inter-code delays disabled.
DATA FORMAT: code identifier disabled, code length not transmitted, no header,
terminator = ENTER, character replacement disabled, address stamping
disabled, address delimiter disabled.
PEN DEFAULT SETTINGS
Interpret operating mode, minimum output pulse 600 μs, conversion to Code
39, overflow medium, output level normal, idle level normal, inter-block delay
disabled.
RADIO PARAMETERS
battery type NiMh
TECHNICAL FEATURES
OM-GRYPHON™
Electrical Features
Supply voltage 9..28 Vdc
Power consumption max. 8 W (charging) *
LED Indicators Battery charging red,
Charge completed green, Power / Data yellow
Time of recharge From 3 to 5 hours
Radio Features
European Models USA Models
Working Frequency 433.92 MHz 910 MHz
Bit rate 19200 baud 36800 baud
Range (in open air) 30 m 15 m
RF Modulation FSK
Max number of devices per
base station
16
Max number of devices in
the same reading area
2000
Environmental Features
Working temperature 0° to +40 °C / 32° to 104 °F
Storage temperature -20° to +70 °C / - 4° to 158 °F
Humidity 90 % non condensing
Protection class IP30
Mechanical Features
Weight about 250 g / 8.81 oz
Dimensions 208 x 107 x 55.5 mm / 8.1 x 4.2 x 2.18 in
Material ABS
* Having a switching regulator inside, the OM-Gryphon™ draws the same
power, regardless of the supply voltage, i.e. as the input voltage increases the
current drawn decreases.
RESTORE DEFAULT
RESTORE OM-GRYPHON™ DEFAULT
Ì$+RX0$-qÎ
To change the defaults refer to the Gryphon™ Dx30/Mx30 Reference Manual, part
number 90ACC1930, or to the Configuration program, both downloadable from the
website.
INTERFACE SELECTION
Select one of the interface codes according to your application.
USB INTERFACE SELECTION
USB-KBD
Ì$+UA03$-:Î
USB-KBD-ALT-MODE
Ì$+UA04$-@Î
USB-COM*
Ì$+UA02$-4Î
USB-IBM-Hand Held
Ì$+UA01$-.Î
* When configuring USB-COM, the relevant files and drivers must be installed
from the USB Device Installation software, which can be downloaded from the
web site http://www.scanning.datalogic.com.
PEN EMULATION INTERFACE SELECTION
PEN
Ì$+CP6$-BÎ
RS232 INTERFACE SELECTION
RS232 Standard
Ì$+CP0$-$Î
Nixdorf Mode A
Ì$+CM2EC0$->Î
Fujitsu
Ì$+CM1$-ÈÎ
ICL Mode
Ì$+CM0$-ÃÎ
WEDGE INTERFACE SELECTION
Wedge IBM AT or PS/2 PCs
Ì$+CP500$-aÎ
PC Notebook
Ì$+CP505$-ÈÎ
PC Notebook - ALT mode
Ì$+CP508$-2Î
IBM AT - ALT mode
Ì$+CP507$-+Î
Many other interfaces are supported and can be selected from the Gryphon™
Dx30/Mx30 Reference Manual available online at http://www.scanning.
datalogic.com. Other supported interfaces:
USB: USB-IBM-Table Top; USB-KBD-APPLE
WEDGE: IBM XT; IBM SURE1; IBM Terminal 3153; IBM Terminals 31xx, 32xx,
34xx, 37xx; Wyse Terminals ANSI – PC –ASCII – VT220 style Keyboards; Digital
Terminal VT2xx/VT3xx/VT4xx; APPLE ADB Bus
KEYBOARD NATIONALITY
USB-KBD and Wedge users should select one of the following wedge keyboard
nationality codes according to your keyboard.
Belge
Ì$+FJ7$-8Î
Deutsch
Ì$+FJ3$-$Î
English
Ì$+FJ4$-)Î
Español
Ì$+FJ6$-3Î
Français
Ì$+FJ2$-ÊÎ
Italiano
Ì$+FJ1$-ÅÎ
Japanese
Ì$+FJ8$-=Î
Svenskt
Ì$+FJ5$-.Î
USA (Default)
Ì$+FJ0$-|Î
DATA FORMAT TERMINATORS
For your convenience, some common Terminators are given below. For othe
r
Header/Terminator selections, Data Format and Advanced Data Format
parameters, see the Gryphon™ Dx30/Mx30 Reference Manual.
CR-LF
Ì$+EA120D0A$-ÃÎ
Enter
Ì$+EA1183$-0Î
Tab
Ì$+EA1184$-8Î
None
Ì$+EA10$-dÎ
OPERATING TEST
Read the TEST code below.
Code 128
test
USING OM-GRYPHON™ RADIO CRADLE
The OM-Gryphon™ cradle, paired with one Gryphon™ M series reader, builds a
Cordless Reading System for the collection, decoding and transmission o
f
barcoded data.
OM-Gryphon™ can be connected to a Host PC through a USB, RS232, Wedge o
Pen emulation cable. All models are suited for single-cradle layouts.
The LEDs signal the OM-Gryphon™ status, as described in the following table:
LED STATUS
Power on /
Data
Yellow On = OM-Gryphon™ is powered.
Yellow Blinking = OM-Gryphon™ receives data and
commands from the Host or the reader.
Charging
Red On = the battery charge is in progress.
Red Blinking = the battery reconditioning is in progress.
Charge
completed
Green On = the battery is completely charged.
Charging +
Charge
completed
Red and Green Blinking together = the reader is not
correctly placed onto the cradle.
D
I
S
C
H
A
R
G
E
To setup your OM-Gryphon™ cradle you must:
1. Make all system connections.
2. Configure the OM-Gryphon™ cradle.
BATTERY SELECTION
Battery selection is required only when the Gryphon™ M reader has an Alkaline
battery and you want to use OM-Gryphon™ either for serial configuration, software
upgrades or to hold Gryphon™ M. Since this type of battery must not be charged it
is necessary to disable the OM-Gryphon™ charge function by following the
procedure:
With the Gryphon™ M read the following code:
1.
Alkaline
Ì$+RN4$-]Î
The green LED on the Gryphon™ M will blink, signaling the reader has
accepted the command.
2.
Place the reader onto the cradle within 10 seconds. The green LED
turns off and a short beep is emitted.
To enable the charge function repeat step 1 and 2 substituting the "Alkaline" code
with the following one:
NiMh
Ì$+RN6$-gÎ
CAUTION
Attempts to charge Alkaline batteries could cause leakage of
liquid, generation of heat or, in extreme cases, explosion. If
using Alkaline batteries, carefully follow the procedure above
to avoid damage.
Reconditioning
battery button
Charging
(red LED)
Power on / Data
(yellow LED)
Charge completed
(green LED)
  • Page 1 1
  • Page 2 2

Datalogic OM-GRYPHON Quick Reference Manual

Tipo
Quick Reference Manual

in altre lingue