VISUALIZED DIGITAL
COUNTER WITH TWO
SET POINTS
Type:
NCM52
VISUALIZED DIGITAL 5 DIGITS COUNTER, WITH
INPUT FOR SINGLE DIRECTIONAL COUNTS, TWO
SET POINTS OF INTERVENTION AND IMPULSES
TOTALIZER.
The NCM 52 counter finds application where there is the
necessity to visualize and to control, through two
programmable set points, mono-directional counts
deriving from electromechanical and logical contacts,
proximity and encoder.
MAIN FEATURES
PROGRAMMABLE PARAMETERS
Frontal keyboard in polycarbonate (antiscratch, antioil,
antacid).
IP65 protection degree
Accessible parameters with key software
Removable terminals connection.
Execution DIN 72 x 72.
Recessed assembly.
Special retaining brackets.
Two set points
Reset time
2 conversion factors of the impulses
Input (Slow / Fast)
Count (Up / Down / Superior)
Memory
Reset key
Set Point 2 in Absolute or Offset mode
Decimal Point
TECHNICAL FEATURES
POWER SUPPLY IN ALTERNATE CURRENT
POWER SUPPLY IN DIRECT CURRENT
POWER SUPPLY TOLERANCE
ABSORPTION
OPERATING TEMPERATURE
CLIMATIC CONDITIONS
COUNTER AND TOTALIZER VISUALIZATION
MULTIPLICATION FACTOR M1 OF THE INPULSES IN INPUT
MULTIPLICATION FACTOR M2 OF THE INPULSES IN INPUT
INPUT TYPE
COUNT FREQUENCY FOR LOGICAL SIGNALS
MINIMUM TIME FOR COUNT IMPULSES
CUT FREQUENCY FOR ELECTROMECHANICAL INPUTS
AUXILIARY INPUTS POWER SUPPLY
COMMAND IMPUTS
OUTPUTS
RELAY RESET
PROGRAMMED DATA MEMORY
: Single power 24 - 110 - 230 Vac (50 / 60 Hz).
: Single power 24 Vdc
: +10% - 15%.
: 2 W - 3 VA.
: -5 °C + 55 °C.
: U.R. 95 % at 40 °C (without condensate).
: 5 digits, 11 mm high
: Programmable from 0,00001 to 9,99999.
: Programmable from 1 to 99.
: Suitable for electromechanical contact and NPN or PNP
signals
: Up to 15 KHz with Duty Cycle=50%.
: 0,25 mSec.
: About 30 Hz.
: 24 Vdc – 80 mA available on terminals.
: 1 Counter Reset - 1 Inhibit.
: 2 relays with operating contacts - capacity 2A - 250Vac.
: Manual or automatic with excitation time from 0,1 to 99,9
sec.
: static (no battery)
CET - s.r.l.
Vers. 1.2
NCM 52
Pag. 2
DESCRIPTION OF THE FRONTAL KEYBOARD
ø
YELLOW
The key 'LEFT ARROW' in normal operating phase visualizes, blinking, all the programmings executed without the
limitation of the insertion code. The time of scansion of the programmings is given from the pressure of the same
key. It exits automatically from this phase after 5 sec of the last pressure of the same key.
In programming phase it moves the cursor of the figure towards left of a step, than at the beginning it is on the right
side first one on the. At the end it resumes from the first one to right.
ù
YELLOW
The key 'UP ARROW' in normal operating phase visualizes the totalizer of impulses.
In programming phase it increases the value of the blinking figure.
ú
BLUE
The key 'PRG' pressed for 2 sec. allows to enter in the programming phase, visualizing on display C.0000.
In the programming phase, pressing key 'PRG' impulsively, it exits from the programming phase. The instrument exits
automatically from the programming phase, 60 sec. after the pressure of the last key.
û
GREEN
The key 'ENT/RES' in normal phase of counting has the 'RESET' function, with the modalities to it attributed in the
programming phase.
In programming phase it confirms and memorizes the visualized data and passes to the successive function. If it has
arrived to list end it resumes from the beginning.
INPUTS / OUTPUTS DESCRIPTION
AC POWER SUPPLY
(inputs 5-6)
AC Power Supply Input of the instrument; it can be to 24 - 110 - 230 VAC in according to demand.
DC POWER SUPPLY
(inputs 7-8)
DC Power Supply Input of the instrument; input 8 (-), input 7 (+).
24 VDC - 80mA
(inputs 9-10)
24 VDC - 80 mA auxiliary Power Supply that the instrument supply to feed the Encoder and proximity amplified.
INPUT
(input 11)
Input of count adapted for electromechanical and logical contacts, encoder and 3 wires proximity amplified,
configurable in Positive (PNP) and Negative (NPN) logic.
RESET
(input 12)
Input of RESET that executes the reset of the visualized count showed on display at the moment of its activation.
INHIBIT
(input 13)
Input of count inhibition: when activated it blocks the count of the normal counter and the totalizer.
RL1
(inputs 1 - 2)
Output of Relay 1, connected to the operation of the Set Point S1. The Common, Normally Open and Normally Close
contacts are available.
RL2
(inputs 3 - 4)
Output of Relay 2, connected to the operation of the Set Point S2. The Common, Normally Open and Normally Close
contacts are available.
DESCRIPTION OF THE LED’S OPERATION
LED 1
It comes activated to the reaching of the Set Points S1.
LED 2
It comes activated to the reaching of the Set Points S2.
CET - s.r.l.
Vers. 1.2
NCM 52
Pag. 3
SET POINTS PROGRAMMING
For SET POINTS programming access, proceed as follow:
- Press key ‘PRG’ in impulsive mode; on display appears:
Ë1 <
99999
S.1 = SET POINT 1, main Set Point, programmable between 0 and 99999. If programmed = 0
the Set Point is excluded and the instrument works like a totalizer and predisposes the count in
UP mode.
Ë2 <
99999
S.2 = SET POINT 2, Point, programmable between 0 and 99999. If it programmed with value
higher or same to S1 it comes reprogrammed like S2 = S.1 - 1.
Key ENT confirms the data and passes to the successive programming. In order to exit the programming, press key PRG.
PROGRAMMING OF THE OPERATION PARAMETERS
The programmable parameters are divided in two groups and protect with a 4 figures code.
In order to approach the programming, proceed in the following way:
- Press key PRG for about 2 sec. On the display appears:
Cod
0000
GROUP 1
:
in order to approach the parameters of group 1, insert code
2357
and press
ENT
Æ1 “
©0000
5 digits multiplier , programmable from 0,1 to 9,9999.This parameter allows to convert the
number of the input impulses, showing them on the display in an other format. If it programmed
= 0 it comes reprogrammed automatically to 1. If a value lower than 1 is inserted, it obtains the
division of the impulses. Es. I want to divide by 25 the impulses in input; calculation 1 : 25 =
0.04.
Attention: the variation of the value of the multiplying modifies automatically the value of the
count and the totalizer.
Æ2 10
2 digits multiplier, programmable from 1 to 99.This parameter allows to convert the number
of the input impulses, showing them on the display in other format. If it programmed = 0 it
comes reprogrammed automatically to 1.
Attention: the variation of the value of the multiplying modifies automatically the value of the
count and the totalizer.
Ìê9²9
t.r. = Time of Automatic Reset, programmable from 0.0 to 99.9 sec. This parameter allows to
make to work the instrument in automatic mode. When the count arrives to the value of S.1, it
automatically resets the count, excites the RL1 relay and it resumes to count without to lose
the impulses. The RL1 relay remains excited for the set up time in t.r. If the time of reset is
programmed = 0 (0.0) the instrument gets ready to works in manual mode.
Particular cases: if the set up time t.r. is bigger than the time employed to the count to arrive
to the values of S.1, the relay will never come unactived.
1æ F
1æ 5
Input Fast - Slow.
This programming allows to predispose the input of count to read signals coming from
electromechanical contacts (relays, switches etc.) that introduces false signals, or from logical
signals like proximity, encoder, transistor etc.)
In = F. predisposes the instrument in order to read logical signals up to 15 KHz.
In = S. predisposes the instrument in order to read electromechanical contacts up to 30 Hz.
Cæ UP
Cæ dæ
Cæ SÈ
Count UP / DOWN / Superior.
Count = Up: the counter gets ready to visualize the count in increasing way (UP), starting
from zero up to the programmed value of set point. To ended count it behave in Manual or
Automatic mode like programmed in t.r.
Count = dn: the counter gets ready to visualize the count in decreasing way (DOWN), starting
from the programmed value of set point to zero. To ended count it behave in Manual or
Automatic mode like programmed in t.r.
Count = Sp: the counter gets ready to visualize the count in increasing way, starting from
zero up to the programmed value of set point. To the attainment of the value of programmed
set point it behave as in the Manual count and continues to count the impulses in input.
CET - s.r.l.
Vers. 1.2
NCM 52
Pag. 4
PROGRAMMING OF THE OPERATION PARAMETERS
The programmable parameters are divided in two groups and protect with a 4 figures code.
In order to approach the programming, proceed in the following way:
- Press key
PRG
for about 2 sec. On the display appears:
Cod
0000
GROUP 2
:
in order to approach the parameters of group 1, insert code
2413
and press
ENT
key
NeÆon
NeÆoF
MEM. = Active or excluded memory.
This parameter allows to program the saving of the current counter value during the power off
of the instrument.
MEM.on. = memorization of the count during the power OFF. When power ON the instrument,
the display will visualize the last present value in the power OFF phase.
MEM.of. = excluded memorization of the count; every time that the instrument comes powered
OFF and then powered ON the count comes lost and the instrument restart always from the
initial condition.
RreËon
reËoF
RES. = RESET Key ON / OFF; this programming enables and disables the RESET function of
frontal key RES during the operation of the counter. The disabling does not allow to reset the
counter and the totalizer.
RES.on = RESET function of key RES enabled
RES.of. = RESET function of key RES disabled
Ë2 AË
Ë2 of
S2 programming in Absolute or Offset mode.
This programming allows uses of S.2 set point in ABSOLUTE or OFFSET value regarding S.1.
S.2 = AS. Programming of S.2 in ABSOLUTE value. The programmed value is the real value
to which it will active the set point S.2 in UP and SP mode. In dn. mode S.2 will active as
impulses before zero as has been programmed. Example of operation in UP and SP. mode
with S1 = 100 and S.2 = 80: the set point S.2 will be active at 80 and S.1. at 100. In DOWN
(dn.) mode, S.2 will be active at 20 (80 impulses before 0) and S.1 = 0.
S.2 = of. Programming of S.2 in OFFSET regarding S.1. With this programming the real value
of S.2 is legacy to the value of S.1. The value of S.2 is obtained from the difference of S.1 and
S.2. In UP and SP. mode, S.2 will be active as impulses before S.1 as has been programmed.
In DOWN (dn.) mode the S.2 set point will be active as impulses before zero as has been
programmed. Es. of operation in UP and SP mode. S1 = 100 and S.2 = 80: the S.2 set pioint
will be active to 20 (80 impulses before S.1) and S.1. to 100. In DOWN (dn.) mode S.2 will be
active to 80 (80 impulses before 0) and S.1 to zero. Changing to the value of S.1, automatically
the absolute value of S.2 changes.
¼È O
¼È 4
d.P. = Programming of the Decimal Point of the Counter and the Totalizer.
This programming allows to add a decimal point to the visualization on the 5 digits, in order to
obtain counts with various resolutions.
d.p. = 0 Decimal Point excluded; visualization 99999
d.p. = 1 Decimal Point on the second display from right; visualization 9999,9
d.p. = 2 Decimal Point on the third party display from right; visualization 999,99
d.p. = 3 Decimal Point on the fourth display from right; visualization 99,999
d.p. = 4 Decimal Point on fifth display from right; visualization 9,9999
Attention, the Decimal Point is fictitious only, it doesn't realize any conversion.
0í1 jö
0í1
-
m
Ou. = Programming of the OUTPUT 1 RL1. This parameter allows to activate the RL1relay to
the beginning _ I or to the end I_ of the count.
Ou.1 _I = Activation of the RL1 relay to end of count
Ou.1 I_ = Activation of the RL1 relay to beginning of count
0í2jö
0í2
-
m
Ou. = Programming of the OUTPUT 2 RL2. This parameter allows to activate the RL2relay to
the beginning _ I or to the end I_ of the count.
Ou.2 _I = Activation of the RL2 relay to end of count
Ou.2 I_ = Activation of the RL2 relay to beginning of count
CET - s.r.l.
Vers. 1.2
NCM 52
Pag. 5
¹È È
¹È ê
A.P. = Activation mode of the programmed parameters.
With this programming is possible to activate the executed programmings directly to the exit of
the programming or, when exited of the programming, after a RESET (with frontal key or from
rear input)
A.P. = P. Activation of the parameters to the exit of the programming.
A.P. = r. Activation of the parameters to the exit of the programming after a RESET.
Pressing the key ù the totalizer of impulses will be visualized for 5 sec.
Toì
99999
The totalizer visualizes all the impulses that the instrument counts from its input IN1.
It can be resetted through frontal key RES only or from RESET input when it is visualized on
the display.
CET - s.r.l.
Vers. 1.2
NCM 52
Pag. 6
OPERATION DIAGRAMS
OPERATION WITH MANUAL INHIBIT AND RESET
OPERATION WITH INHIBIT AND AUTOMATIC RESET
POWER SUPPLY
INHIBIT
INPUT
COUNT 1
RELAY 1
COUNT 2
RELAY 2
RESET
POWER SUPPLY
INHIBIT
INPUT
COUNT 1
RELAY 1
COUNT 2
RELAY 2
TIME RESET
CET - s.r.l.
Vers. 1.2
NCM 52
Pag. 7
DECLARATION OF ‘CE’ CONFORMITY
CE NORMATIVE CONFORMITY
Borgolavezzaro, October, 03rd 2005
The building firm:
CET s.r.l.
Head office:
Strada Statale 211, Km 53,3
28071 Borgolavezzaro (No) ITALIA
Tel. 0039 - (0)321 - 885301 Fax. 0039 - (0)321 - 885560
declare that the products:
type :
Electronic Counter
model:
NCM 52
use class:
Industrial
are in conformity with the following normatives:
EN55011
ENV50141
ENV50204
EN61000-4-2
EN61000-4-4
The constructor :
CET s.r.l.
________________________________
Signature
CET - s.r.l.
Vers. 1.2
NCM 52
Pag. 8
CONNECTIONS
INPUT SIGNALS
TTL LOGIC TTL LOGIC
NPN PNP
+ -
ENCODER AND AMPLIFIED
PROXIMITY - 24dc
CONTACT CONTACT
NPN PNP
PROGRAMMING PROGRAMMING
NPN PNP
RESET INHIBIT
NPN NPN
RESET INHIBIT
PNP PNP
DIMENSIONS
FRONT SIDE
REAR
DRILL
TEMPLATE
CET
CETCET
CET
CET
CETCET
CET
s.r.l.
Strada Statale 211 Km 53,550
28071 Borgolavezzaro - NO - ITALY
Tel : ++39 0321-885180/885301/885807
Fax : ++39 0321-885560
http://www.cet-italy.com
e-mail: info@cet-italy.com
Agent:
PROX
ENCOD
9
11
10
11
10
11
9
10
11
9
11
10
12
10
13
9
12
9
13
72
72
ENT
RES
PROG
RL1
NCM
36952
è
CET
RL2
electronic counter
113
85
9
19
67
REMOVABLE
TERMINALS
RETAINING
BRACKETS
10
MAX
67
67
1 2 3 4 5 6 7 8
9 10 11 12 13 14
68
68
+
-
POWER SUPPLY
VAC 24 VDC
RESET
+
-
24 VDC
COUNT
INHIBIT
RL1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
RL2