Datalogic Scanning Scanner 1000I Manuale utente

Categoria
Lettori di codici a barre
Tipo
Manuale utente

Questo manuale è adatto anche per

Magellan
®
1000i
Omni-Directional Imaging Scanner
Quick Reference Guide
Guida Rapida
Guide de Référence Rapide
Guía de Referencia Rápida
Schnellanleitung
Referência Rápida
Datalogic Scanning, Inc.
959 Terry Street
Eugene, Oregon 97402
Telephone: (541) 683-5700
Fax: (541) 345-7140
An Unpublished Work - All rights reserved. No part of the contents of this documen-
tation or the procedures described therein may be reproduced or transmitted in any
form or by any means without prior written permission of Datalogic Scanning, Inc.
or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”). Owners of Dat-
alogic products are hereby granted a non-exclusive, revocable license to reproduce
and transmit this documentation for the purchaser's own internal business pur-
poses. Purchaser shall not remove or alter any proprietary notices, including copy-
right notices, contained in this documentation and shall ensure that all notices
appear on any reproductions of the documentation.
Should future revisions of this manual be published, you can acquire printed ver-
sions by contacting your Datalogic representative. Electronic versions may either be
downloadable from the Datalogic website (www.scanning.datalogic.com) or pro-
vided on appropriate media. If you visit our website and would like to make com-
ments or suggestions about this or other Datalogic publications, please let us know
via the "Contact Datalogic" page.
Disclaimer
Datalogic has taken reasonable measures to provide information in this manual
that is complete and accurate, however, Datalogic reserves the right to change any
specification at any time without prior notice.
Datalogic is a registered trademark of Datalogic S.p.A. and the Datalogic logo is a
trademark of Datalogic S.p.A. all licensed to Datalogic Scanning, Inc. All other
trademarks and trade names referred to herein are property of their respective
owners.
This product may be covered by one or more of the following patents: 4603262 • 4639606 • 4652750 • 4672215 • 4699447
• 4709369 • 4749879 • 4786798 • 4792666 • 4794240 • 4798943 • 4799164 • 4820911 • 4845349 • 4861972 • 4861973 •
4866257 • 4868836 • 4879456 • 4939355 • 4939356 • 4943127 • 4963719 • 4971176 • 4971177 • 4991692 • 5001406 •
5015831 • 5019697 • 5019698 • 5086879 • 5115120 • 5144118 • 5146463 • 5179270 • 5198649 • 5200597 • 5202784 •
5208449 • 5210397 • 5212371 • 5212372 • 5214270 • 5229590 • 5231293 • 5232185 • 5233169 • 5235168 • 5237161 •
5237162 • 5239165 • 5247161 • 5256864 • 5258604 • 5258699 • 5260554 • 5274219 • 5296689 • 5298728 • 5311000 •
5327451 • 5329103 • 5330370 • 5347113 • 5347121 • 5371361 • 5382783 • 5386105 • 5389917 • 5410108 • 5420410 •
5422472 • 5426507 • 5438187 • 5440110 • 5440111 • 5446271 • 5446749 • 5448050 • 5463211 • 5475206 • 5475207 •
5479011 • 5481098 • 5491328 • 5493108 • 5504350 • 5508505 • 5512740 • 5541397 • 5552593 • 5557095 • 5563402 •
5565668 • 5576531 • 5581707 • 5594231 • 5594441 • 5598070 • 5602376 • 5608201 • 5608399 • 5612529 • 5629510 •
5635699 • 5641958 • 5646391 • 5661435 • 5664231 • 5666045 • 5671374 • 5675138 • 5682028 • 5686716 • 5696370 •
5703347 • 5705802 • 5714750 • 5717194 • 5723852 • 5750976 • 5767502 • 5770847 • 5786581 • 5786585 • 5787103 •
5789732 • 5796222 • 5804809 • 5814803 • 5814804 • 5821721 • 5822343 • 5825009 • 5834708 • 5834750 • 5837983 •
5837988 • 5852286 • 5864129 • 5869827 • 5874722 • 5883370 • 5905249 • 5907147 • 5923023 • 5925868 • 5929421 •
5945670 • 5959284 • 5962838 • 5979769 • 6000619 • 6006991 • 6012639 • 6016135 • 6024284 • 6041374 • 6042012 •
6045044 • 6047889 • 6047894 • 6056198 • 6065676 • 6069696 • 6073849 • 6073851 • 6094288 • 6112993 • 6129279 •
6129282 • 6134039 • 6142376 • 6152368 • 6152372 • 6155488 • 6166375 • 6169614 • 6173894 • 6176429 • 6188500 •
6189784 • 6213397 • 6223986 • 6230975 • 6230976 • 6237852 • 6244510 • 6259545 • 6260763 • 6266175 • 6273336 •
6276605 • 6279829 • 6290134 • 6290135 • 6293467 • 6303927 • 6311895 • 6318634 • 6328216 • 6332576 • 6332577 •
6343741 • 6454168 • 6478224 • 6568598 • 6578765 • 6705527 • 6974084 • 6991169 • 7051940 • 7170414 • 7172123 •
7201322 • 7204422 • 7215493 • 7224540 • 601 26 118.6 • AU703547 • D312631 • D313590 • D320011 • D320012 •
D323492 • D330707 • D330708 • D349109 • D350127 • D350735 • D351149 • D351150 • D352936 • D352937 • D352938
• D352939 • D358588 • D361565 • D372234 • D374630 • D374869 • D375493 • D376357 • D377345 • D377346 •
D377347 • D377348 • D388075 • D446524 • EP0256296 • EP0260155 • EP0260156 • EP0295936 • EP0325469 •
EP0349770 • EP0368254 • EP0442215 • EP0498366 • EP0531645 • EP0663643 • EP0698251 • EP01330772 •
GB2252333 • GB2284086 • GB2301691 • GB2304954 • GB2307093 • GB2308267 • GB2308678 • GB2319103 •
GB2333163 • GB2343079 • GB2344486 • GB2345568 • GB2354340 • ISR107546 • ISR118507 • ISR118508 • JP1962823
• JP1971216 • JP2513442 • JP2732459 • JP2829331 • JP2953593 • JP2964278 • MEX185552 • MEX187245 • RE37166
• Other Patents Pending
Quick Reference Guide i
Table of Contents
English .......................................................... 1
Italiano ........................................................... 5
Español ......................................................... 9
Portugues .................................................... 13
Francais ....................................................... 17
Deutsch ....................................................... 21
Chinese .......................................................25
Japanese ..................................................... 29
ii Magellan
®
1000i
NOTES
Quick Reference Guide i
DATALOGIC SCANNING, INC. MAGELLAN
®
END
USER LICENSE AGREEMENT
Notice to End User: The Datalogic Product you have acquired contains embedded Soft-
ware, which is integral to the product's operation. This Software is being provided to
you under license, subject to the terms and conditions of this Agreement. If you use the
Datalogic Product, you will be deemed to have accepted the terms and conditions of this
Agreement. If you do not intend to be bound to the terms of this Agreement, Datalogic is
not willing to license the Software to you, you may not use the Datalogic Product or the
Software, and you must contact the party from whom you acquired the Datalogic Product
for instructions.
This End User Software License Agreement ("Agreement") is a legally binding agreement gov-
erning the licensing of the Software and Documentation by Datalogic,Scanning Holdings, Inc.
and its subsidiaries and affiliates ("Datalogic") to the entity or person who has purchased or oth-
erwise acquired a Datalogic Product ("End User"). For purposes of this Agreement, any soft-
ware that is associated with a separate end-user license agreement is licensed to you under the
terms of that license agreement. Datalogic and End User hereby agree as follows:
1. Definitions
.
1.1 "Documentation" means materials such as user's guides, program reference guides,
quick reference guides, manuals, or similar materials associated with or related to the
Datalogic Product, whether in printed, "online", or other form.
1.2 "Proprietary Information" means: (a) source code, object code, software, documentation,
and any related internal design, system design, data base design, algorithms, technol-
ogy, technical data or information, implementation techniques, and trade secrets related
to the Software, (b) any other trade secrets marked appropriately or identified as propri-
etary or confidential, and (c) any information that End User, under the circumstances,
should recognize as confidential. Proprietary Information does not include any informa-
tion that the receiving party can establish was (1) in the public domain, (2) already in the
receiving party's possession or rightfully known prior to receipt, (3) rightfully learned from
a third party not in violation of any other's proprietary rights, or (4) independently devel-
oped without access to Proprietary Information.
1.3 "Datalogic Product" means the Datalogic Magellan® 1000i series, Magellan® 1400i
series, Magellan® 8100 series, Magellan® 8200 series, Magellan® 8300 series, Magel-
lan® 8400 series, Magellan® 8500 series, Magellan® 9500 series, and/or Magellan SL®
series scanner and/or scanner/scale product, including all embedded Software in and all
Documentation related to such product, which has been purchased or otherwise
acquired by End User, whether obtained directly or indirectly from Datalogic.
1.4 "Software" means any software or computer programs of Datalogic or its third party licen-
sors in machine readable form which is embedded in the Datalogic Product, whether
obtained directly or indirectly from Datalogic, including any replacement, update,
upgrade, enhancement or modification.
2. Scope Of License Granted.
2.1 Datalogic grants to End User a non-exclusive, non-transferable, perpetual license to use
the Software, solely on the Datalogic Product in which it is embedded ("designated Data-
logic Product"), in machine-readable form only, solely for End User's internal business
purposes. This Agreement does not convey ownership of the Software to End User.
Title to the Software shall be and remain with Datalogic or the third party from whom Dat-
alogic has obtained a licensed right. As used in this Agreement, the term "purchase" or
its equivalents when applied to the Software shall mean "acquire under license." End
User is not entitled to receipt or use of the source code to any Software.
2.2 End User shall not copy, modify, decompile, disassemble, reverse engineer, or otherwise
reproduce or remanufacture the Software, whether modified or unmodified, nor sell,
assign, sublicense, distribute, lend, rent, give, or otherwise transfer the Software to any
other person or organization, for purposes other than as expressly provided in this
Agreement, without Datalogic's prior written consent.
3. Transfers, Support.
ii Magellan
®
1000i
3.1 Any copying, installing, reproduction, remanufacture, reverse engineering, electronic
transfer, or other use of the Software on other than the designated Datalogic Product will
be a material breach of this Agreement. However, Datalogic may elect not to terminate
this Agreement or the granted licenses, but instead may elect to notify End User that End
User is deemed to have ordered and accepted a license for each breaching use. End
User shall pay Datalogic the applicable list price for such licenses as of the date of such
breach.
3.2 End User shall not sell, assign, sublicense, distribute, lend, rent, give, or otherwise trans-
fer the Datalogic Product to any third party unless such third party agrees with Datalogic
in writing to be bound by the terms and conditions of this Agreement. Any such transfer
of the Datalogic Product absent such agreement shall be null and void.
3.3 End User may obtain support for Software from Datalogic at Datalogic's standard sup-
port fees and under Datalogic's standard support terms and conditions in effect at the
time the support is requested.
4. Intellectual Property.
End User acknowledges that the Software constitutes valuable trade secrets of Datalogic or
Datalogic's third party licensors and that the Software is protected by intellectual property laws
and treaties. The license set forth in this Agreement does not transfer to End User any owner-
ship of Datalogic's or its third party licensors' copyrights, patents, trademarks, service marks,
trade secrets, or other intellectual property rights and End User shall have no right to com-
mence any legal actions to obtain such rights. End User shall not remove, modify, or take any
other action that would obscure any copyright, trademark, patent marking, or other intellectual
property notices contained in or on the Datalogic Product.
5. Proprietary Information.
5.1 End User acknowledges that Proprietary Information is the confidential, proprietary, and
trade secret property of Datalogic and Datalogic's third party licensors and End User
acquires no right or interest in any Proprietary Information.
5.2 End User shall not disclose, provide, or otherwise make available the Proprietary Infor-
mation of Datalogic or its third party licensors to any person other than End User's autho-
rized employees or agents who are under confidentiality agreement, and End User shall
not use the Proprietary Information other than in conjunction with use of the Datalogic
Product exclusively for End User's internal business purposes. End User shall take
steps to protect the Proprietary Information no less securely than if it were End User's
own intellectual property.
5.3 The provisions of this Proprietary Information Section shall survive and continue for five
(5) years after the termination of this Agreement.
6. Limited Warranty.
6.1 Datalogic warrants that, under normal use and operation, the Datalogic Product will con-
form substantially to the applicable Documentation for the period specified in the Docu-
mentation. During this period, for all reproducible nonconformities for which Datalogic
has been given written notice, Datalogic will use commercially reasonable efforts to rem-
edy nonconformities verified by Datalogic. End User agrees to supply Datalogic with all
reasonably requested information and assistance necessary to help Datalogic in reme-
dying such nonconformities. For all defects reported to Datalogic within the warranty
period, Datalogic's liability is limited to providing End User with one copy of corrections or
responding to End User's problem reports according to Datalogic's standard assistance
practices. Datalogic does not warrant that the product will meet End User's requirements
or that use of the product will be uninterrupted or error free, or that Datalogic's remedial
efforts will correct any nonconformance. This limited warranty does not cover any prod-
uct that has been subjected to damage or abuse, whether intentionally, accidentally, or by
neglect, or to unauthorized repair or unauthorized installation, and shall be void if End
User modifies the product, uses the product in any manner other than as established in
the Documentation, or if End User breaches any of the provisions of this Agreement.
6.2 EXCEPT AS PROVIDED IN THIS AGREEMENT, THE DATALOGIC PRODUCT IS PRO-
VIDED "AS IS" AND DATALOGIC MAKES NO WARRANTIES OF ANY KIND, EXPRESS
OR IMPLIED, WRITTEN OR ORAL, WITH RESPECT TO THE PRODUCT, AND SPE-
CIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE.
7. Infringement.
Quick Reference Guide iii
7.1 Datalogic will defend End User against any claim in a lawsuit that the Datalogic Product
furnished hereunder infringe a United States patent or copyright of a third party and Dat-
alogic will pay any damages finally awarded against End User by a court of competent
jurisdiction that are attributable to such claim or will pay End User's part of any settle-
ment that is attributable to such claim, provided, that 1) End User notifies Datalogic
promptly in writing of the claim, 2) Datalogic controls the defense or settlement of the
claim, and 3) End User cooperates fully with Datalogic in such defense or settlement. All
notices of a claim should be sent to Datalogic Scanning Holdings, Inc., Legal Depart-
ment, 959 Terry Street, Eugene, OR 97402.
7.2 In the defense or settlement of any such claim, Datalogic may, at its option, 1) procure for
End User the right to continue using the Datalogic Product, 2) modify the Datalogic Prod-
uct so that it becomes non-infringing, 3) replace the Datalogic Product with an equivalent
product not subject to such claim, or 4) provide End User an opportunity to return the
Datalogic Product and receive a refund of the purchase price paid, less a reasonable
allowance for use.
7.3 Datalogic shall have no liability to End User for claims of infringement based upon 1) the
use of any Datalogic Product in combination with any product which Datalogic has not
either furnished or authorized for use with such Datalogic Product 2) the use of any Dat-
alogic Product designed, manufactured, or modified to the specifications of End User, or
3) End User's modification of the Datalogic Product without written authorization from
Datalogic.
7.4 THE FOREGOING STATES DATALOGIC'S COMPLETE AND ENTIRE OBLIGATION
CONCERNING CLAIMS OF PATENT, COPYRIGHT, OR OTHER INTELLECTUAL
PROPERTY INFRINGEMENT, CANCELS AND SUPERSEDES ANY PRIOR AGREE-
MENTS, WHETHER ORAL OR WRITTEN, BETWEEN THE PARTIES CONCERNING
SUCH CLAIMS, AND WILL NOT BE MODIFIED OR AMENDED BY ANY PAST, CON-
TEMPORANEOUS, OR FUTURE AGREEMENTS OR DEALINGS BETWEEN THE
PARTIES, WHETHER ORAL OR WRITTEN, EXCEPT AS SET FORTH IN A FUTURE
WRITING SIGNED BY BOTH PARTIES.
8. Limitation Of Liability.
EXCEPT AS PROVIDED IN SECTION 7, DATALOGIC SHALL NOT BE LIABLE FOR ANY
CLAIMS AGAINST END USER BY ANY OTHER PARTY. IN NO EVENT SHALL DATALOGIC'S
LIABILITY FOR DAMAGES, IF ANY, WHETHER BASED UPON CONTRACT, TORT (INCLUD-
ING NEGLIGENCE), PRODUCT LIABILITY, STRICT LIABILITY, WARRANTY, OR ANY OTHER
BASIS, EXCEED THE PRICE OR FEE PAID BY END USER FOR THE DATALOGIC PROD-
UCT. UNDER NO CIRCUMSTANCES SHALL DATALOGIC BE LIABLE TO END USER OR
ANY THIRD PARTY FOR LOST PROFITS, LOST DATA, INTERRUPTION OF BUSINESS OR
SERVICE, OR FOR ANY OTHER SPECIAL, CONSEQUENTIAL, CONTINGENT, INDIRECT,
INCIDENTAL, PUNITIVE, EXEMPLARY, OR OTHER SIMILAR DAMAGES, EVEN IF DATA-
LOGIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
9. Government Restricted Rights; International Use.
9.1 Use, duplication, or disclosure of the Software by the U.S. Government is subject to the
restrictions for computer software developed at private expense as set forth in the U.S.
Federal Acquisition Regulations at FAR 52.227-14(g), or 52.227-19 or in the Rights in
Technical Data and Computer Software clause at DFARS 252.227-7013(c)(1)(ii), which-
ever is applicable.
9.2 If End User is using the Datalogic Product outside of the United States, End User must
comply with the applicable local laws of the country in which the Datalogic Product is
used, with U.S. export control laws, and with the English language version of this Agree-
ment. The provisions of the "United Nations Convention on International Sale of Goods"
shall not apply to this Agreement.
10. Termination.
10.1 Either party may terminate this Agreement or any license granted under this Agreement
at any time upon written notice if the other party breaches any provision of this Agree-
ment.
10.2 Upon termination of this Agreement, End User immediately shall cease using any non-
embedded software and shall return to Datalogic or destroy all non-embedded software
covered by this Agreement, and shall furnish Datalogic with a certificate of compliance
with this provision signed by an officer or authorized representative of End User. For
embedded software, End User agrees to sign a waiver prepared by Datalogic concerning
further use of the embedded Software. End User's resumed or continued use of the
iv Magellan
®
1000i
embedded Software after termination shall constitute End User's agreement to be bound
by the terms and conditions of this Agreement for such use.
11. General Provisions.
11.1 Entire Agreement; Amendment. This document contains the entire agreement between
the parties relating to the licensing of the Software and supersedes all prior or contempo-
raneous agreements, written or oral, between the parties concerning the licensing of the
Software. This Agreement may not be changed, amended, or modified except by written
document signed by Datalogic.
11.2 Notice. All notices required or authorized under this Agreement shall be given in writing,
and shall be effective when received, with evidence of receipt. Notices to Datalogic shall
be sent to the attention of Contract Administration, Datalogic Scanning Holdings, Inc.,
959 Terry Street, Eugene, OR 97402, or such other address as may be specified by Dat-
alogic in writing.
11.3 Waiver. A party's failure to enforce any of the terms and conditions of this Agreement
shall not prevent the party's later enforcement of such terms and conditions.
11.4 Governing Law; Venue: This Agreement and the rights of the parties hereunder shall be
governed by and construed in accordance with the laws of the State of Oregon U.S.A,
without regard to the rules governing conflicts of law. The state or federal courts of the
State of Oregon located in either Multnomah or Lane counties shall have exclusive juris-
diction over all matters regarding this Agreement, except that Datalogic shall have the
right, at its absolute discretion, to initiate proceedings in the courts of any other state,
country, or territory in which End User resides, or in which any of End User's assets are
located.
11.5 Attorneys’ Fees. In the event an action is brought to enforce the terms and conditions of
this Agreement, the prevailing party shall be entitled to reasonable attorneys' fees, both
at trial and on appeal.
- END -
Quick Reference Guide 1
Quick Reference
This guide is provided to help get your installation up-and-run-
ning quickly and efficiently. For more details, including program-
ming information, reference the Product Reference Guide (PRG),
which is available for viewing and download from the Datalogic
website listed on the back cover of this manual.
Installation
Route the interface cable from the terminal or host. Plug the AC
adapter (if one is used) into a wall outlet and the interface (I/F)
cable, then route and attach the I/F cable to the scanner. Verify
operation by presenting known-good bar codes to the scanner.
The unit should beep
1
and/or flash its good read LED and send
the bar code data to the host or terminal. If not, refer to the Trou-
bleshooting section of this guide.
Scanner installation is complete.
1. Beeper and LED behavior is selectable and may have been disabled
by a previous user.
I/F Cable
Connect
Here
A/C Adapter
(if needed)
For 220-230 VAC
adapters, the
cord must be
facing down as
shown in the
illustration. If
installed upwards,
it will pose an
undue strain on the
socket outlet.
To Host/Terminal
2Magellan
®
1000i
Optional Stand
An optional stand is available for the scanner which can be
permanently attached to a wall or countertop. After locating the
stand in an optimal position, the scanner (along with the stand)
can be detached for portable use by lifting the entire unit as
shown below.
Power Supply
Models require
1
either a Listed class II or class III with a Limited
Power Source (LPS). For the safety certification to be valid, class
III input power sources must be IEC/EN60950-1 (EN 60335-
series, EN 60065 or relevant) approved.
Input: 100 - 240 VAC Output: 5 - 14 VDC (check scanner voltage option)
Max. Current: 1 A Max. Power: 14 W
How to Scan
Bar codes can be presented to the scanner while it is resting on
the counter or in the optional stand, or the scanner/mount can be
lifted and held as shown.
1. Power Off the Terminal (POT) units do not require a power supply.
*Optional Stand
Switch Option Shown
Quick Reference Guide 3
Targeted Scanning Mode
In order to read a bar code (switch option only)...
press and hold the switch. An aiming pattern will
appear.
with the aiming pattern fairly centered over the bar code
to be read, release the switch to read the label.
Troubleshooting
If the scanner is not operating properly, the following checks
should be performed:
1. If the scanner uses an external power supply and the external
power supply has failed, the scanner will not operate.
Exchange the power supply with a known good power sup-
ply and retest operation.
2. Verify the interface cable is securely attached to the host.
Consult your technical support personnel or refer to your
host system manual to verify the proper connection for the
scanner.
NOTE
The scanner will not read bar codes while the
switch is pressed.
Targeted Scanning Mode will read bar codes
in any orientation.
The scanner will return to full pattern Omni
Mode after a configurable time has elapsed.
1
2
4
Product
Reference
Guide
5
3
4Magellan
®
1000i
3. Verify that the interface cable is securely attached to the scan-
ner.
4. Check that the bar codes are of sufficient quality to be recog-
nized by the scanner. Wrinkled, smudged, or torn labels can
cause the scanner to not read at all. Scan known-good labels
of an active symbology
1
to check the scanner's read opera-
tion.
5. Ensure that the scanner's interface type is compatible with
the host terminal by consulting your POS system manual
and/or the Product Reference Guide.
If the scanner still does not function properly, contact your local
supplier or Datalogic Customer Support Services.
Compliance Statement
This device complies with Part 15 rules. Operation is subject to
the following conditions:
1. This device may not cause harmful interference; and
2. This device must accept any interference received, including
interference that may cause undesired operation.
This Class A digital apparatus complies with Canadian ICES -003.
Cet appareil numérique de la classe A est confrome à la norme NMB-003 du
Canada.
LED Class
CLASS 1 LED PRODUCT APPARECCHIO LED CLASSE 1
LED KLASSE 1 APPAREIL A LED DE CLASSE 1
EN60825-1
1. Reading of the various bar code symbologies can be independently
enabled or disabled in the scanner.
Guida Rapida 5
Guida Rapida
La presente guida vi aiuterà ad eseguire un'installazione rapida ed effi-
cace. Per ulteriori dettagli, inclusi i dettagli relativi alla programmazione,
consultare la Guida di Riferimento del Prodotto, che può essere consul-
tata online e scaricata dal sito di Datalogic indicato sul retro del presente
manuale.
Installazione
Svolgere il cavo d'interfaccia dal terminale o host. Inserire l'eventuale
adattatore CA nella presa a parete e nel cavo d'interfaccia (I/F), quindi
collegare il cavo I/F allo scanner. Verificare il funzionamento facendo leg-
gere allo scanner dei codici a barre dei quali si conosce il contenuto e in
buono stato. L'unità emettera un suono
1
e/o farà lampeggiare il LED che
segnala la corretta lettura del codice e invierà i dati del codice all'host o al
terminale. In caso contrario, consultare la sezione "Risoluzione dei prob-
lemi" della presente guida.
L'installazione dello scanner è completa.
1. È possibile selezionare suono oppure LED. Tenere conto della config-
urazione impostata dall'utente che ha utilizzato lo scanner in prece-
denza.
Cavo d'interfaccia
Collegare
qui
Adattatore C
(se necessario)
All'host/terminale
Il cavo degli
adattatori 220-230
VCA deve essere
posizionato verso il
basso come
indicato
nell'illustrazione. In
caso contrario
l'uscita della presa
di corrente sarà
sotto sforzo.
6Magellan
®
1000i
Supporto Opzionale
È disponibile un supporto opzionale che può essere attaccato perma-
nentemente alla parete o sul bancone. Dopo aver posizionato il supporto
in posizione ottimale, lo scanner e il supporto potranno essere staccati
per l'utilizzo mobile sollevando l'intera unità come illustrato in basso.
Alimentazione
Questi modelli
1
devono essere alimentati con alimentatori omologati di
classe II o classe III LPS (Limited Power Source, sorgente di corrente lim-
itata). Affinché il certificato di sicurezza sia valido, le sorgenti di alimen-
tazione di classe III devono essere conformi a IEC/EN60950-1 (serie EN
60335, EN60065 o relativi).
Tensione ingresso: 100 - 240 VAC Tensione uscita: 5 - 14 VDC
Consumo massimo: 1.0 A Potenza massima: 14 W.
Come utilizzare lo Scanner
È possibile presentare i codici al lettore, mentre è posizionato sul ban-
cone oppure inserito nel supporto opzionale, oppure lo scanner può
essere sollevato come da illustrazione.
1. Le unità alimentate dal terminale (POT - Power Off the Terminal) non
richiedono alimentazione di rete.
*Supporto opzionale
Pulsante opzione
Guida Rapida 7
Modalità di Scansione a Bersaglio
Per utilizzare lo scanner con il pulsante opzione:
tenere premuto il pulsante. Apparirà un mirino luminoso.
Posizionare il mirino luminoso al centro del codice a barre da
leggere e rilasciare il pulsante opzione per eseguire la lettura.
Risoluzione dei Problemi
Nel caso lo scanner non funzionasse correttamente, eseguire i seguenti
controlli:
1. Se lo scanner utilizza un'alimentazione esterna e quest'ultima non
fosse operativa, lo scanner non funzionerà. Utilizzare una sorgente
di alimentazione affidabile e riprovare.
2. Verificare che il cavo d'interfaccia sia saldamente collegato all'host.
Consultare il proprio personale tecnico oppure il manuale del
sistema host per controllare il corretto collegamento dello scanner.
NOTE
Lo scanner non legge i codici, se il pulsante è
premuto.
La modalità di scansione bersaglio consente
di leggere codici orientati in qualunque verso.
Lo scanner ritornerà in modalità Omni dopo
un periodo di tempo impostabile.
1
2
4
Product
Reference
Guide
5
3
8Magellan
®
1000i
3. Verificare che il cavo d'interfaccia sia saldamente collegato allo scan-
ner.
4. Controllare che i codici a barre siano di qualità sufficientemente
leggibile per lo scanner. Etichette piegate, strappate o sbavate
potrebbero non essere leggibili. Utilizzare etichette sicuramente leg-
gibili che appartenengono ad un sistema di simbologia
1
utilizzato
per controllare il funziomento dello scanner in lettura.
5. Assicurarsi che il tipo di interfaccia dello scanner sia compatibile
con il teminale/host consultando il manuale del POS e/o la Guida
di riferimento del prodotto.
Se lo scanner non funziona correttamente, contattare il rivenditore locale
oppure il Servizio Assistenza Clienti di Datalogic.
Dichiarazione di Conformità
Il presente dispositivo è conforme ai regolamenti Part 15. Il funziona-
mento è soggetto alle seguenti condizioni:
1. il dispositivo non deve causare interferenze dannose; e
2. il dispositivo deve accettare qualsiasi interferenza ricevuta, incluso le
interferenze che potrebbero causare un funzionamento non desider-
ato.
Il presente apparto digtale di Classe A è conforme alla normativa canadese
ICES-003.
Classe LED
CLASS 1 LED PRODUCT APPARECCHIO LED CLASSE 1
LED KLASSE 1 APPAREIL A LED DE CLASSE 1
PRODOTTO LED CLASSE 1 EN60825-1
1. La lettura delle varie simbologie dei codici a barre può essere indipen-
dentemente abilitata o disabilitata nello scanner.
Guía de referencia rápida 9
Guía de Referencia Rápida
La finalidad de esta guía es ayudarle a instalar el equipo de forma rápida y
eficiente. Para obtener más datos, incluida información de programación,
consulte la Guía de referencia del producto (PRG) que podrá ver y des-
cargar de la página Web de Datalogic, cuya dirección aparece en la con-
tracubierta de este manual.
Instalación
Encamine el cable de interfaz desde el terminal o el equipo central.
Conecte el adaptador de CA (si se utiliza uno) a una toma de corriente de
pared y al cable de interfaz (I/F). A continuación encamine y conecte el
cable I/F al escáner. Para comprobar el funcionamiento, coloque un
código de barras en buen estado ante el escáner. La unidad emitirá un
pitido
1
y/o parpadeará el LED de lectura correcta y enviará los datos del
código de barras al equipo central o al terminal. Si no es así, consulte la
sección Solución de averías de esta guía.
La instalación del escáner ha finalizado.
1. El funcionamiento del indicador acústico y el LED es seleccionable y
es posible que un usuario anterior lo haya desactivado.
Cable de interfaz
Conectar
aquí
Adaptador
de CA (si es
necesario)
Al equipo
central/terminal
Si se utilizan
adaptadores de
220-230 V CA, el
cable debe
orientarse hacia
abajo, como
muestra la imagen.
Si se instala hacia
arriba, ejercerá una
tensión indebida
sobre la toma de
corriente.
10 Magellan
®
1000i
Soporte Opcional
Existe un soporte opcional para el escáner que puede acoplarse de
forma permanente a una pared o a un mostrador. Después de
colocar el soporte en la posición óptima, se podrá desmontar el
escáner (junto con el soporte) si desea trasladarlo de lugar. Para
ello, solo tiene que elevar la unidad completa, tal y como muestra
la imagen.
Suministro Eléctrico
Se require fuente limitada
1
de alimentación (LPS) alistada en la clase II o
la clase III para estos modelos. La certificación de seguridad solamente es
válida si las enchufadas para fuente de alimentación clase III están apro-
badas por IEC-EN60950-1 (serie EN 60335, EN 60065 o comparable).
Enchufada 100-240 VAC Despacho 5 - 14 VDC
Corriente máximo 1.0 A Poder máximo 20 W
Instrucciones Para Escanear
Los códigos de barras pueden colocarse delante del escáner mientras éste
permanece apoyado sobre el mostrador o el soporte opcional. También es
posible elevar y sostener el escáner/unidad como muestra la imagen.
1. Las unidades de desconexión del terminal (POT) no precisan una
fuente de alimentación.
*Soporte opcional
Opción de interruptor mostrada
Guía de referencia rápida 11
Modo de Exploración de Objetivo
Para leer un código de barras (solo opción de interruptor)...
Mantenga pulsado el interruptor. Aparecerá un haz para apun-
tar.
Centre el haz para apuntar lo s posible sobre el código de
barras que vaya a leer y suelte el interruptor para leer la eti-
queta.
Solución de Problemas
Si el escáner no funciona correctamente, deberán realizarse las siguientes
comprobaciones:
1. Si el escáner utiliza una fuente de alimentación externa y dicha
fuente se ha averiado, el escáner no funcionará. Cambie la fuente de
alimentación por otra en buen estado y restablezca el funciona-
miento.
2. Compruebe que el cable de interfaz está perfectamente acoplado al
equipo central. Pida ayuda al personal de asistencia técnica o con-
sulte el manual del sistema central para comprobar que el escáner
esta correctamente conectado.
NOTA
El escáner no leerá códigos de barras mien-
tras el interruptor permanezca pulsado.
El modo de exploración de objetivo leerá los
códigos de barras en cualquier dirección.
El escáner volverá al modo de haz completo
una vez que haya transcurrido un tiempo con-
figurable.
1
2
4
Product
Reference
Guide
5
3
12 Magellan
®
1000i
3. Compruebe que el cable de la interfaz está perfectamente acoplado
al escáner.
4. Compruebe que los códigos de barras tienen la calidad suficiente
para ser reconocidos por el escáner. El escáner no leerá etiquetas
arrugadas, emborronadas o rasgadas. Para comprobar el funciona-
miento de la función de lectura del escáner, explore etiquetas que
contengan una simbología activa en buen estado
1
.
5. Asegúrese de que el tipo de interfaz del escáner es compatible con el
terminal central. Para ello, consulte el manual del sistema POS y/o
la Guía de referencia del producto.
Si el escáner sigue sin funcionar correctamente, póngase en contacto con
su proveedor local o con el Departamento de Atención al Cliente de Dat-
alogic.
Nota de Conformidad
Este dispositivo cumple las normas recogidas en la Sección 15. El funcio-
namiento está sujeto a las condiciones siguientes:
1. Este dispositivo no causará interferencia peligrosa, y
2. Este dispositivo aceptará cualquier interferencia recibida, incluida
aquella que pueda causar un funcionamiento no deseado.
Este aparato digital de Clase A cumple la normativa canadiense ICES -003.
Clase de LED
CLASS 1 LED PRODUCT APPARECCHIO LED CLASSE 1
LED KLASSE 1 APPAREIL A LED DE CLASSE 1
PRODUCTO LED de CLASE 1 EN60825-1
1. La lectura de distintas simbologías de códigos de barras puede acti-
varse o desactivarse de forma independiente en el escáner.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Datalogic Scanning Scanner 1000I Manuale utente

Categoria
Lettori di codici a barre
Tipo
Manuale utente
Questo manuale è adatto anche per