Ohaus Valor 1000 (WMVS0012) Manuale del proprietario

Tipo
Manuale del proprietario

Questo manuale è adatto anche per

Valor 1000 Series
Instruction Manual
Serie Valor 1000
Manual de Instrucciones
Série Valor 1000
Guide de I’utilisateur
Serie Valor 1000
Bedienungsanleitung
Serie Valor 1000
Manuale d’instruzioni
OHAUS ValorTM 1000 Series EN-1
1. INTRODUCTION
This manual contains installation, operation and maintenance instructions for the
Ohaus ValorTM 1000 Series Scales. Please read the manual completely before using
the scale.
1.1 Safety Precautions
Please follow these safety precautions:
• Verify AC Adapter input voltage matches the local AC power supply.
• Do not immerse the scale in water or other liquids.
• Do not operate the scale in hostile environments.
• Do not drop loads on the platform.
• Do not place the scale upside down on the pan.
• Service should only be performed by authorized personnel
• Disconnect the scale from the power supply when cleaning
1.2. Controls
Figure 1-1. Controls.
1
2
3
6
5
47
10 9 8
EN-2 OHAUS ValorTM 1000 Series
TABLE 1-1. CONTROLS
Item Description
1 Low battery indicator
2 Battery charge indicator
3 Level Bubble
4 Center of Zero, NET, Stability Sum icons
5 7-segment, 6 digit backlit LCD w/ units of measure enunciators
6 Over, Under , Accept Check weigh indicators
7 Control Buttons
8 Adjustable feet
9 Power input jack
10 On/Off Power Switch
TABLE 1-2. CONTROL FUNCTIONS.
Button Action Function
Short Press Sets display to zero ZERO
Enter
Menu Press Confirms settings
Short Press Tares weight of item on pan TARE
Menu Press Decrement over and under settings
Short press Stores displayed weight in accumulation memory
Display accumulation data when display is at zero
Menu Press Increment over and under settings
M+
Units
Long Press Change unit of measure while already pressing
SELECT button
Short press Shift to next digit when setting over and under values SELECT
Units
Long Press Change unit of measure together with short press of
M+ button
OHAUS ValorTM 1000 Series EN-3
2. INSTALLATION
2.1 Package Contents
• Valor 1000 Scale
• Stainless steel Pan
• AC Power Adapter
• Instruction Manual
• Warranty Card
2.2 Location
Use the scale on a firm, steady surface. Avoid locations with excessive air current,
vibrations, heat sources, or rapid temperature changes. Adjust the leveling feet so the
bubble is centered in the circle.
Figure 2-1. Leveling the Scale.
2.3 Power
Connect the AC Adaptor to the AC mains supply. Connect the plug to the DC jack on
the bottom of the scale. The scale may be operated on the AC mains supply or the
built in rechargeable battery. The scale must be turned on to charge the battery.
Figure 2-2. Power Connection
2.3.1 Battery Power
4xLevel
Level Bubble
DC
j
ack
EN-4 OHAUS ValorTM 1000 Series
The scale can be operated on the internal rechargeable battery when AC power is not
available. The scale will automatically switch to battery operation if there is a power
failure or the power cord is removed.
Before using the scale for the first time, the battery should be fully
charged for up to 12 hours. During charging, the battery Indicator
displays the charge level (see table 1-1), and the scale can be operated
during charging. The battery is protected against over charging and the
scale can remain connected to the AC power line.
NOTE:
• Charging the scale must only be performed in a dry environment
CAUTION: Battery is to be replaced only by an authorized Ohaus service
dealer
Risk of explosion can occur if replaced with the wrong type or connected
improperly
Dispose of the lead acid battery according to local laws and regulations
2.4 Initial Calibration
When the scale is operated for the first time, a Span calibration is recommended to
ensure accurate weighing results. Before performing the calibration, be sure to have
the appropriate calibration weight.
Refer to section 4.3 for Span calibration procedures.
OHAUS ValorTM 1000 Series EN-5
3. OPERATION
3.1 Turning Scale On/Off
To turn the scale on, flip the toggle switch below the right front keyboard. The scale
performs a display test, momentarily displays software version, and then enters the
active weighing mode. To turn the scale off, toggle same switch to off position.
3.2 Zero Operation
Zero is set under the following conditions:
• Automatically at Power On (initial zero).
• Manually by pressing the ZERO button.
Press the ZERO button to zero the weight display. The scale must be stable and
weight +/- 2% of capacity to accept zero operation.
3.3 Manual Tare
Place a container on the weighing pan, then press TARE. The display will show a net
value of “0”. To clear the Tare value, press TARE with the pan empty.
3.4 Weighing Mode
Use this mode to measure the weight of a sample in the selected unit of measure.
Press and hold SELECT and press M+ Unit until the desired unit icon is displayed.
Press ZERO to set the display to zero. Put an empty container on the pan, and then
press TARE to tare the container weight. Add material to the container. The display
shows the weight of the material in selected unit of measure.
EN-6 OHAUS ValorTM 1000 Series
3.5 Accumulate Mode
Use this mode to store the weight and HI, LO, SUM statistics from a series of
samples.
Press ZERO to set the display to zero.
Place the sample on the pan, wait for stabilization.
Press M+ to store the weight of the sample. Storage is confirmed by the display [n---
-x], where x is the sample number. The enunciator above SUM text will illuminate to
let user know there are readings in memory. Remove the sample, wait for stable zero
reading, then place the next sample on the pan. Press M+ to store the weight of the
next sample. Repeat this process until all samples have been weighed.
Review the accumulation data by pressing M+ when the display is at zero.
The display shows the number of samples [n----x]
Press M+ to view the maximum sample weight [Hxxxxx].
Press M+ to view the minimum sample weight [Lxxxxx].
Press M+ to view the sum of weights [xxxxx].
Press M+ to return to weighing.
Clear the accumulated data by pressing ZERO when the number of samples is
displayed. Note – when stored values are in memory, unit of measure cannot be
changed.
3.6 Check Weigh Mode
Use this mode to compare samples to a target weight range.
Press ZERO to set the display to zero. Place a sample on the pan and read the
weight and under / accept / over status on display. (Refer to section 4.1 to set
limits)
3.7 Changing Units of Measure
Press and hold the SELECT key, and while still holding the SELECT key, press M+
button to display the next available measuring unit. Repeat process to scroll through
all units.
OHAUS ValorTM 1000 Series EN-7
4. SETTINGS
The scale allows the user to customize several settings including check weigh limits,
backlight operation and calibration.
4.1 Over and Under Limits
Press and hold SELECT, and while still pressing SELECT, press ZERO until [SET--HL]
is displayed.
Press ZERO to view the upper limit [000000].
Press SELECT (§), TARE (©), M+ (ª) to edit the digits of the upper limit.
Press ENTER (ZERO Key) to confirm the setting and display the lower limit
[000000].
Press SELECT (§), TARE (©), M+ (ª) to edit the lower limit.
Press ENTER (ZERO Key) to confirm the lower setting and display will show Run---X
where x is the alarm setting. In this case x=
0 = Turns off check weigh mode
1 = under / accept / over indicators are displayed, alarm beeps when weight is
outside accept range.
2 = under / accept / over indicators are displayed, alarm beeps when weight is
within accept range.
3 = under / accept / over indicators are displayed, alarm is off.
Press TARE & M+ to change the alarm to desired setting.
Press ENTER (ZERO key) to confirm setting and display [EndSEt]
When [EndSEt] is displayed, Press and hold SELECT, and while still pressing
SELECT, press ZERO key to return to weighing.
4.2 Backlight
Press and hold ZERO button until [bL---x] is displayed, where x=
0 = backlight is turned off
1 = backlight is on during weighing (15 seconds of no activity)
2 = backlight is always on
Press TARE to change the setting. Press ZERO to confirm the setting and return to
weighing.
EN-8 OHAUS ValorTM 1000 Series
4.3 CALIBRATION
Span Calibration:
Turn on the scale. When the display flashes all of the segments ("1~9"),
simultaneously press and hold the ZERO and SELECT key. When "999999" is
displayed release both buttons. The display reads "CAL ---"
Press ZERO key to display "A____x" (x=divisions in grams:1,2,5,10,20,50).
Press ZERO key to accept the default division setting which is shown on the display.
Do not change default.
Display shows "b____x" (x=decimal point:0,1,2,3,4). Press ZERO key to accept the
default decimal point setting which is shown on the display. Do not change default.
Display shows "Cxxxxx" (xxxxx=Capacity of scale). Press ZERO key to accept the
default Capacity setting which is shown on the display. Do not change default.
Display shows "d____x" (x=Zero tracking setting:0-6 from 0d to 5d). Press ZERO
key to accept the default setting which is shown on the display.
The display shows "E____x" (x=0, Accumulation and Check Weighing available;
x=1, Accumulation and Check Weighing are not available). Press the ZERO key to
accept the default setting which is shown on the display.
Press ZERO and display will show "Load 0". Make sure pan is empty then press
ZERO key to accept. Display will show "Load F”.
Press ZERO to display "Fxxxxx" (xxxxx=Span weight ). To accept the default span
weight, put displayed weight on the scale, and press ZERO to accept it.
If span weight is not available, the user can select a lower span calibration point
value. Use the SELECT (scroll to next digit), TARE (decrease blinking digit) and M+
(increase blinking digit) keys to increment or decrement span calibration values.
Once the desired span calibration weight is set, place displayed weight on the scale,
and press ZERO to accept it. After completion, The display shows “EndCAL” and the
scale will return to the weighing mode.
To abort calibration at any point, turn the scale off. To restart calibration, follow the
procedure from the beginning.
OHAUS ValorTM 1000 Series EN-9
5. MAINTENANCE
Caution: before cleaning, turn off the scale, remove the AC adapter.
5.1 Cleaning
The housing may be cleaned with a cloth dampened with a mild detergent if
necessary. Do not use solvents, chemicals, alcohol, ammonia or abrasives to clean
the housing or control panels.
5.2 Troubleshooting
The following table lists common problems and possible causes and remedies. If the
problem persists, contact Ohaus or your authorized dealer.
TABLE 5-1. TROUBLESHOOTING.
Symptom Possible Cause(s) Remedy
Scale will not turn on No power to scale •
Battery power used up
Verify connections and voltage •
Connect power and charge the battery
Poor accuracy Improper calibration •
Unstable environment
Perform calibration •
Move scale to suitable location
Unable to calibrate Unstable environment •
Incorrect calibration mass
Move the scale to suitable location •
Use correct calibration mass
Scale flashes Bat Battery discharged Connect power and charge the battery
Battery fails to charge
fully
Battery is defective Have battery replaced by authorized
service dealer
ZEro-E Pan has load during power on Remove weight from pan and re-zero
ZEro-E Pan was removed Install pan and re-zero.
-Over- Weight on pan exceeds
capacity
Remove weight from the pan
Err-01 Invalid under and over limit
settings
Re-enter under and over limits
Ad-Lo Incorrect Calibration Setting or
incorrect Calibration weight
Correct the Calibration setting or
Calibration weight
5.3 Service Information
If the troubleshooting section does not resolve or describe your problem, contact
your authorized Ohaus service agent. For service assistance or technical support in
the United States call toll-free 1-800-526-0659 between 8.00 AM and 5:00 PM
EST. An Ohaus product service specialist will be available to provide assistance.
Outside the USA, please visit our web site, www.ohaus.com to locate the Ohaus
office nearest you.
EN-10 OHAUS ValorTM 1000 Series
6. TECHNICAL DATA
The technical data is valid under the following ambient conditions:
Ambient temperature: 0°C to 40°C, Maximum Relative humidity: 80% for
temperatures up to 31°1C, decreasing linearity to 50% relative humidity at 40°C.
Height above sea level: Up to 2000m. Operability is assured at ambient
temperatures between 0°C and 40°C Power: AC adapter : 9 or12 VDC, Protection:
Protected against dust and water, Pollution degree: 2 , Installation category: Class
III, EMC: See Declaration of Conformity
6.1 Specifications
TABLE 6-1. Specifications.
Single Display Models V11P6
Dual Display Models V11P6T/
V11P6TG*
Capacity (kg) 6
Readability (g) 1
Repeatability (g) 2
Linearity (g) 2
Weighing Units* Kilograms, Pounds, Grams, Ounces
App Modes Weigh, Accumulate, Checkweigh
Tare range To capacity by subtraction
Stabilization Time 3 seconds
Power requirements 9 VDC 500 mA AC adapter (supplied)
Internal rechargeable sealed lead acid battery
Calibration Digital with external weight
Battery Life 80/100 hours (with/without backlight on)
Display Type 6-digit 7-segment LCD with blue backlight
Display Size 20 mm / 0.8 in digits
Pan Size 250 x 180 mm. / 9.9 x 7.1in.
Dimensions 255w x 305d x 115h mm / 10w x 12d x 4.5h in
Net Weight 3.2 kg / 7 lb
Shipping Weight 4.0 kg / 8.8 lb
* V11PxTG models have only Kilogram and Gram units enabled
OHAUS ValorTM 1000 Series EN-11
6.2 Compliance
Compliance to the following standards is indicated by the corresponding mark on the
product.
This product conforms to the EMC directive 2004/108/EC and the Low
Voltage Directive 2006/95/EC. The complete declaration of Conformity
is available online at www.ohaus.com.
Disposal
In conformance with the European Directive 2002/96/EC on Waste
Electrical and Electronic Equipment (WEEE) this device may not be
disposed of in domestic waste. This also applies to countries outside the
EU, per their specific requirements.
The Batteries Directive 2006/66/EC introduces new requirements from
September 2008 on removability of batteries from waste equipment in
EU Member States. To comply with this Directive, this device has been
designed for safe removal of the batteries at end-of-life by a waste
treatment facility.
Please dispose of this product in accordance with local regulations at
the collecting point specified for electrical and electronic equipment.
If you have any questions, please contact the responsible authority or the
distributor from which you purchased this device.
Should this device be passed on to other parties (for private or
professional use), the content of this regulation must also be related.
For disposal instructions in Europe, refer to www.ohaus.com, choose
your country then search for WEEE.
Thank you for your contribution to environmental protection.
FCC Note
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
EN-12 OHAUS ValorTM 1000 Series
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his
own expense.
Industry Canada Note
This Class A digital apparatus complies with Canadian ICES-003.
OHAUS ValorTM 1000 Series EN-13
ISO 9001 Registration
In 1994, Ohaus Corporation, USA, was awarded a certificate of registration to ISO
9001 by Bureau Veritus Quality International (BVQI), confirming that the Ohaus
quality management system is compliant with the ISO 9001 standard’s
requirements. On May 21, 2009, Ohaus Corporation, USA, was re-registered to the
ISO 9001:2008 standard.
LIMITED WARRANTY
Ohaus products are warranted against defects in materials and workmanship from
the date of delivery through the duration of the warranty period. During the warranty
period Ohaus will repair, or, at its option, replace any component(s) that proves to
be defective at no charge, provided that the product is returned, freight prepaid, to
Ohaus.
This warranty does not apply if the product has been damaged by accident or
misuse, exposed to radioactive or corrosive materials, has foreign material
penetrating to the inside of the product, or as a result of service or modification by
other than Ohaus. In lieu of a properly returned warranty registration card, the
warranty period shall begin on the date of shipment to the authorized dealer. No
other express or implied warranty is given by Ohaus Corporation. Ohaus Corporation
shall not be liable for any consequential damages.
As warranty legislation differs from state to state and country to country, please
contact Ohaus or your local Ohaus dealer for further details.
Serie OHAUS ValorTM 1000 ES-1
1. INTRODUCCIÓN
Este manual contiene instrucciones de instalación, operación y mantenimiento para
las básculas de la serie ValorTM 1000 de Ohaus. Por favor lea completamente el
manual antes de usar la báscula.
1.1 Precauciones de seguridad
Por favor siga estas precauciones de seguridad:
• Verifique que el voltaje de entrada del adaptador de corriente alterna (CA) coincida
con el voltaje del suministro eléctrico CA local.
• No sumerja la báscula en agua u otros líquidos.
• No opere la báscula en ambientes hostiles.
• No deje caer objetos sobre la plataforma.
• No coloque la báscula al revés sobre la bandeja de pesaje.
• El mantenimiento debe ser realizado solamente por personal autorizado.
• Desconecte la báscula de la fuente de alimentación cuando la esté limpiando.
1.2. Controles
Figura 1-1. Controles.
1
2
3
6 5
47
8 9 10
ES-2 Serie OHAUS ValorTM 1000
TABLA 1-1. CONTROLES.
Ítem Descripción
1 Indicador de batería baja
2 Indicador de carga de batería
3 Burbuja de nivel
4 Íconos de suma de acumulado, NET y de estabilidad
5 Indicadores de verificación de peso por arriba, por abajo y aceptable
6 Pantalla con iluminación de fondo de LCD de 7-segmentos, 6-dígitos
con anunciadores de medida
7 Teclas
8 Patas ajustables
9 Enchufe de entrada de energía
10 Interruptor de encendido (On/Off)
TABLA 1-2. FUNCIONES DE CONTROL.
Botón Acción Función
Pulsación corta Establece la pantalla en cero ZERO
Enter
Pulsación en Menú Confirma las configuraciones
Pulsación corta Tara el peso del elemento que está en la
bandeja de pesaje
TARE
Pulsación en Me Disminuye las configuraciones por arriba y
por abajo
Pulsación corta Almacena el peso mostrado en la memoria
de acumulación
Muestra los datos de acumulación cuando la
pantalla está en cero.
Pulsación en Me Aumenta las configuraciones por arriba y por
abajo
M+
Units
(unidades)
Pulsación larga Cambia la unidad de medida al hacer una
pulsación larga del botón SELECT
(seleccionar)
Pulsación corta Cambia al siguiente dígito cuando se
configuran valores por arriba y por abajo
SELECT
(seleccionar)
Units
(unidades)
Pulsación larga Cambia la unidad de medida al hacer una
pulsación corta del botón M+
Serie OHAUS ValorTM 1000 ES-3
2. INSTALACIÓN
2.1 Contenido del paquete
• Báscula Valor 1000
• Bandeja de acero inoxidable
• Adaptador de corriente CA
• Manual de instrucciones
• Tarjeta de garantía
2.2 Ubicación
Use la báscula en una superficie firme y segura. Evite lugares con corrientes de aire
excesivas, vibraciones, fuentes de calor o cambios bruscos de temperatura. Ajuste
las patas niveladoras para que la burbuja esté centrada en el círculo.
Figura 2-1. Nivelación de la báscula.
2.3 Alimentación
Conecte el adaptador de corriente alterna al enchufe de entrada principal. Inserte la
clavija en la toma DC en la parte inferior de la báscula. La báscula puede ser
utilizada con suministro de corriente alterna CA o con la batería recargable interna.
La báscula debe estar encendida para recargar la batería.
Figura 2-2. Conexión de corriente
SI NO
Patas
niveladoras
Burbuja de nivel
A
limentación
principal
ES-4 Serie OHAUS ValorTM 1000
2.3.1 Corriente de batería
La báscula puede ser usada con la batería interna recargable cuando la energía de
la corriente CA no esté disponible. La báscula cambiará automáticamente a la
operación con batería si hay una falla de corriente o si se quita el cable de corriente.
Antes de usar la báscula por primera vez, la batería debe ser cargada
completamente hasta por 12 horas. Durante la carga, el indicador de
batería muestra el nivel de carga (consulte la tabla 1-1), y la báscula
puede ser usada mientras se está cargando. La batería está protegida
contra sobrecargas y la báscula puede permanecer conectada al cable
de corriente CA.
NOTA:
• La carga de la báscula solo debe realizarse en un ambiente seco.
PRECAUCIÓN: La batería solo debe ser reemplazada por un distribuidor
de Ohaus autorizado.
Puede producirse un riesgo de explosión si se reemplaza con un tipo
equivocado o si se conecta de forma inapropiada.
La eliminación de la batería de plomo-ácido debe hacerse de acuerdo a
las leyes y regulaciones locales.
2.4 Calibración inicial
Cuando la báscula es utilizada por primera vez, se recomienda hacer una
calibración de rango para asegurar resultados de pesaje exactos. Antes de realizar
la calibración, asegúrese de tener el peso de calibración apropiado.
Consulte la sección 4.3 para los procedimientos de calibración de rango.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

Ohaus Valor 1000 (WMVS0012) Manuale del proprietario

Tipo
Manuale del proprietario
Questo manuale è adatto anche per