Datalogic STARGATE specificazione

Tipo
specificazione

Questo manuale è adatto anche per

BC-80X0 Cradle
Quick Reference Guide
Datalogic ADC, Inc.
959 Terry Street
Eugene, OR 97402
USA
Telephone: (541) 683-5700
Fax: (541) 345-7140
©2007-2014 Datalogic, Inc.
An Unpublished Work - All rights reserved. No part of the contents of this docu-
mentation or the procedures described therein may be reproduced or transmitted
in any form or by any means without prior written permission of Datalogic ADC,
Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic ADC). Owners of Data-
logic products are hereby granted a non-exclusive, revocable license to reproduce
and transmit this documentation for the purchaser's own internal business pur-
poses. Purchaser shall not remove or alter any proprietary notices, including copy-
right notices, contained in this documentation and shall ensure that all notices
appear on any reproductions of the documentation.
Should future revisions of this manual be published, you can acquire printed ver-
sions by contacting your Datalogic representative. Electronic versions may either
be downloadable from the Datalogic website (www.datalogic.com) or provided on
appropriate media. If you visit our website and would like to make comments or
suggestions about this or other Datalogic publications, please let us know via the
"Contact Datalogic" page.
Disclaimer
Datalogic has taken reasonable measures to provide information in this manual
that is complete and accurate, however, Datalogic reserves the right to change any
specification at any time without prior notice.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in
many countries, including the U.S.A. and the E.U. All other brand and product
names may be trademarks of their respective owners.
Patents
This product may be covered by the following patent:
US Pat. 7,948,214 B2.
Additional patents pending.
BC-80X0
1
USING THE BC-80X0 RADIO CRADLE
The BC-80X0 cradle, paired with one or more Powerscan™ M8300 readers,
builds a Cordless Reading System for the collection, decoding and transmission
of barcoded data.
It can be connected to a Host PC through an RS-232, USB, Wedge or Pen
cable and is suited for single-cradle point-to-point layouts. It can also be
connected to a C-BOX and therefore integrated into a fixed scanner application.
The BC-8060 models also allow multi-cradle layouts through an RS-485
Network. For this network connection refer to the Powerscan™ D8330/M8300
Reference Manual.
The label on the cradle contains LED indicators and a scan finder button.
When the button is pressed, the cradle transmits a “broadcast” message. All
properly configured scanners (Radio RX Timeout set to keep the radio “awake”)
that are linked to that base (through a bind or a join sequence) and within radio
range coverage will emit a beep sequence once every 2 seconds for 30
seconds. This functionality is useful to:
- verify which scanners are linked to a certain base station
- detect a scanner forgotten somewhere
The LEDs signal the BC-80X0 status, as described in the following table:
LED
STATUS
Aux
Yellow On = BC-80X0 is powered through an external power supply.
Yellow Blinking = BC-80X0 transmission occurs over the Host port.
Host
Yellow On = BC-80X0 is powered by the Host.
Yellow Blinking = BC-80X0 transmission occurs over the Host port.
Reader
Green On = the reader battery is completely charged.
Red On = the reader battery is charging.
Orange Blinking = reader battery fault – replace battery.
Red / Green Alternatively Blinking = charging error - see Ref. Manual
Spare*
Green On = the spare battery is completely charged.
Red On = the spare battery is charging.
Orange Blinking = spare battery fault – replace battery.
Red / Green Alternatively Blinking = charging error - see Ref. Manual
* This LED refers to the accessory SBS-8000 Spare Battery Slot when mounted to the BC-8060. Not
available for BC-8010 models.
Figure 1 – Cradle Overview
DATALOGIC
2
To set up your BC-80X0 cradle you must:
1. Physically install the cradle.
2. Make all system connections.
3. Configure the BC-80X0 cradle.
INSTALLATION
MOUNTING THE BC-80X0 CRADLE
The cradle package contains the following items:
BC-80X0
1 horizontal base
BC-80X0 Quick Reference Guide
2 wall-mounting lock hinges
BC-8000 Antenna
4 rubber feet
2 adhesive strips
1 inclined base
The cradle can be mounted for portable or fixed desktop usage, or it can be
fixed to a wall. The horizontal base allows portable and fixed desktop usage,
while the inclined base provides desktop and wall mounting guaranteeing a
comfortable handling of the Powerscan™ M8300 reader.
BC-80X0 Cradle mounted on the Horizontal Base
BC-80X0 Cradle mounted on the Inclined Base
BC-80X0
3
Desktop mounting
For desktop usage, you can mount the cradle either on the horizontal base, for
reduced overall dimensions, or on the inclined base for a more ergonomic taking
out and insertion of the reader onto the cradle.
Horizontal base
Top View Bottom View
Inclined base
Top View Bottom View
Mounting
Tabs (4)
Mounting
Holes (2)
Rubber Foot
Seat (4)
Adhesive
Strip Seat (2)
Cable
Channels
Mounting
Tabs (4)
Mounting
Holes (4)
Cable
Channels
Adhesive
Strip Seat (2)
Rubber
Foot Seat (4)
DATALOGIC
4
PORTABLE DESKTOP USE
1. Correctly position the BC-80X0 onto the base by sliding it along the
mounting tabs until aligned.
1
2
1
2
2. Carefully clean the rubber foot seats of the base to remove any impurities
that could reduce adhesion.
3. Remove the protective plastic from the rubber feet and stick them onto the
bottom surface of the base.
4. If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole
on the body of the cradle and screw it clockwise until tight.
FIXED DESKTOP USE
For fixed desktop installation, use the adhesive strips or fixing screws (not
provided) according to your needs.
For mounting with adhesive strips:
1. Position the cradle onto the base by sliding it along the mounting tabs until
aligned.
2. Carefully clean the adhesive strip seats of the base to remove any
impurities that could reduce adhesion.
3. Remove the protective plastic from one side of the adhesive strips and
stick them onto the base surface.
4. Position the cables to be connected to the BC-80X0 cradle along the
dedicated channels, as shown in the figures below:
Horizontal Base
Inclined Base
BC-80X0
5
5. Remove the plastic from the other side of the strips and affix the base to
the table.
6. If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole
on the body of the cradle and screw it clockwise until tight.
For mounting with screws:
1. Position the cables to be connected to the BC-80X0 cradle along the
dedicated channels, as shown in the figures below:
2. Position the base on the table and affix it by means of the screws (not
provided).
3. Position the cradle on the base by sliding it along the mounting tabs until
aligned.
4. If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole
on the body of the cradle and screw it clockwise until tight.
Wall Mounting
1. Remove the yellow caps and insert the two wall mounting lock hinges
provided with your cradle.
DATALOGIC
6
2. Position the cables to be connected to the BC-80X0 cradle along the
dedicated channels (see figures at page 4).
If using the adhesive strips:
3. Carefully clean the adhesive strip
seats of the base to remove any
impurities that could reduce
adhesion.
4. Remove the protective plastic
from one side of the adhesive
strips and stick them onto the
base surface.
5. Remove the plastic from the
other side of the strips and affix
the base to the wall as indicated
in the figure below.
If using the mounting screws:
3. Using the mounting holes on the
base as a pattern, mark the wall
where you desire to mount the
BC-80X0.
4. Drill the appropriate size holes
and insert the threaded dowels
(not provided) into the holes.
5. Position the base on the wall as
indicated in the figure below and
affix it by means of the screws
(not provided).
Inclined Base Wall-mounting
6. Attach the cradle on the base by sliding it along the mounting tabs until
aligned.
7. If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole
on the body of the cradle and screw it clockwise until tight.
BC-80X0
7
APPLYING RAPID POINT-TO-POINT CONFIGURATION
LABEL (OPTIONAL)
A pre-printed barcode label is included in the
package for rapid configuration of point-to-
point applications. If you wish to use this
method, apply this label to the seat provided
on the BC-80X0 cradle as shown in the
figure. See the Powerscan™ M8300 Quick
Reference Manual for the configuration
procedure.
SYSTEM CONNECTIONS
Connections should always be made with power off!
CAUTION
The BC-80X0 cradle provides two interface connectors and a power supply
connector as shown in the figure on the next page:
The RS-485 Network connection is available only on BC-8060 models. For
details about this type of connection, refer to the Powerscan™ D8330/M8300
Reference Manual.
To connect the BC-80X0 cradle to the Host through the multi-interface
connector, use the cable corresponding to the desired interface type.
Power Supply
RS-485
(BC-8060 only)
MULTI-INTERFACE
RS-232, USB, Wedge,
PEN Emulation
DATALOGIC
8
CONNECTING AND DISCONNECTING THE BC-80X0
INTERFACE CABLE
The BC-80X0 can be connected to a Host by means of an RS-232, USB, Wedge
or Pen cable, which must be simply plugged into the Host connector, visible on
the front panel of the cradle.
To disconnect the cable, insert a paper clip or other similar object into the hole
corresponding to the Host connector on the body of the cradle. Push down on the
clip while unplugging the cable. Refer to the following figure:
Connecting/Disconnecting the Cable
RS-232
USB
Power
Multi-standard interface
RS-232, USB, WEDGE, or
PEN Emulation to Host
BC-80X0
9
WEDGE
PEN
C-BOX
Powerscan™ M
BC-80X0
BIND
JOIN
C-BOX
Scanner
System cables to Host
DATALOGIC
10
BC-80X0 CONFIGURATION
The BC-80X0 configuration can be performed in three ways: by using the
Datalogic Aladdin™ software configuration program, by sending configuration
strings from the Host PC via the RS-232 or USB-COM interface or by reading
configuration barcodes with the Powerscan™ M reader.
DATALOGIC ALADDIN™
Datalogic Aladdin™ is a multi-platform utility program providing a quick and
user-friendly configuration method via the RS-232/USB-COM interface.
It also allows upgrading the software of the connected device (see the Datalogic
Aladdin™ Help On-Line for more details).
SERIAL CONFIGURATION
By connecting the BC-80X0 to a PC through an RS-232 or USB-COM interface
cable it is possible to send configuration strings from the PC to BC-80X0.
CONFIGURATION BARCODES
Once you have performed system connection and Powerscan M reader
configuration, you can configure the BC-80X0 cradle by reading configuration
barcodes. Apply power to the BC-80X0.
For Powerscan™ M configuration, refer to the “Powerscan™ M8300 Quick
Reference”.
To configure the BC-80X0 using the Powerscan™ M reader (the one paired to the
cradle with the Bind command), follow the procedure according to the interface
selected.
RESTORE DEFAULT
RESTORE BC-80X0 DEFAULT
Ì$+RX0$-qÎ
To change the defaults refer to the "Powerscan™ D8330/M8300 Reference
Manual", or to the Datalogic Aladdin™ Configuration program, both
downloadable from the website.
BC-80X0
11
INTERFACE SELECTION
Select one of the interface codes according to your application.
USB INTERFACE SELECTION
USB-KBD
Ì$+UA03$-:Î
USB-KBD – ALT-mode
Ì$+UA04$-@Î
USB-COM*
Ì$+UA02$-4Î
USB-IBM-Hand Held
Ì$+UA01$-.Î
USB-IBM Table top
Ì$+UA00$-(Î
USB KBD-APPLE
* When configuring USB-COM, the relevant files and drivers must be installed
from the USB Device Installation Software, which can be downloaded from
the web site http://www.scanning.datalogic.com.
PEN EMULATION INTERFACE SELECTION
PEN
Ì$+CP6$-BÎ
DATALOGIC
12
INTERFACE SELECTION
Select one of the interface codes according to your application.
RS-232 INTERFACE SELECTION
RS-232 Standard
Ì$+CP0$-$Î
Nixdorf Mode A
Ì$+CM2EC0$->Î
Fujitsu
Ì$+CM1$-ÈÎ
ICL Mode
Ì$+CM0$-ÃÎ
WEDGE INTERFACE SELECTION
Wedge IBM AT or PS/2 PCs
Ì$+CP500$-aÎ
PC Notebook
Ì$+CP505$-ÈÎ
PC Notebook - ALT mode
Ì$+CP508$-2Î
IBM AT - ALT mode
Ì$+CP507$-+Î
Interfaces for IBM XT and IBM Terminals 3151, 347X and 348X can be selected
from the PowerScan D8330/M8300 Reference Manual available online at
http://www.datalogic.com.
BC-80X0
13
KEYBOARD NATIONALITY
USB-KBD and Wedge users should select one of the following wedge
keyboard nationality codes according to your keyboard.
Belge
Ì$+FJ7$-8Î
Deutsch
Ì$+FJ3$-$Î
English
Ì$+FJ4$-)Î
Español
Ì$+FJ6$-3Î
Français
Ì$+FJ2$-ÊÎ
Italiano
Ì$+FJ1$-ÅÎ
Svenskt
Ì$+FJ5$-.Î
USA (Default)
Ì$+FJ0$-|Î
DATALOGIC
14
The following Keyboard Nationality selections are only valid for IBM AT
compatible PCs:
Japanese
Ì$+FJ8$-=Î
Russian (Latin)
Ì$+FJ9$-BÎ
Russian (Cyrillic)
Ì$+FJA$-jÎ
Hungarian
Ì$+FJB$-oÎ
Slovenian, Croatian, Serbian (Latin)
Ì$+FJC$-tÎ
Romanian
Ì$+FJD$-yÎ
Czech Republic
Ì$+FJE$-~Î
BC-80X0
15
DATA FORMAT TERMINATORS
For your convenience, some common Terminators are given below. For other
Header/Terminators selections, Data Format and Advanced Data Format
parameters see the Powerscan™ D8330/M8300 Reference Manual.
CR-LF
Ì$+EA120D0A$-ÃÎ
Enter
Ì$+EA1183$-0Î
Tab
Ì$+EA1184$-8Î
None
Ì$+EA10$-dÎ
DATALOGIC
16
BC-80X0 DEFAULT CONFIGURATION
USB-KBD DEFAULT SETTINGS
USA keyboard, FIFO enabled, inter-character and inter-code delays disabled,
USB keyboard speed normal.
DATA FORMAT: code identifier disabled, code length not transmitted, character
replacement disabled, reader and cradle address stamping disabled, reader and
cradle address delimiter disabled, time stamping disabled, time stamping
delimiter disabled, no header, terminator = ENTER.
RS-232 DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, ack/nack protocol
disabled, FIFO enabled, delay disabled, 5 sec. rx timeout
DATA FORMAT: code identifier disabled, code length not transmitted, character
replacement disabled, reader and cradle address stamping disabled, reader and
cradle address delimiter disabled, time stamping disabled, time stamping
delimiter disabled, no header, terminator = CR-LF.
WEDGE DEFAULT SETTINGS
USA keyboard, Caps Lock off, Caps Lock Auto-Recognition enabled, num lock
unchanged, inter-character and intercode delay disabled, control character
emulation = ctrl+shift+key.
DATA FORMAT: code identifier disabled, code length not transmitted, character
replacement disabled, reader and cradle address stamping disabled, reader and
cradle address delimiter disabled, time stamping disabled, time stamping
delimiter disabled, no header, terminator = ENTER.
PEN DEFAULT SETTINGS
Interpret operating mode, conversion to code 39, output level normal, idle level
normal, minimum output pulse 600 s, overflow medium, inter-block delay
disabled.
NETWORK PARAMETERS
RS-485 network disabled (for BC-8000 only).
BC-80X0
17
OPERATING TEST
Read the TEST codes below.
EAN-8
1 2 3 4 5 6 7 0
EAN-13
1 2 3 4 5 6 7 0 0 0 9 9 2
Code 39 (Normal)
1 7 1 6 2
Code 39 (Normal)
Code 128
t e s t
Interleaved 2 of 5
0 1 2 3 4 5 6 7 8 4
YOUR SYSTEM IS NOW READY TO READ CODES AND TO SEND THE
DATA TO THE HOST.
DATALOGIC
18
TECHNICAL FEATURES
BC-80X0
Electrical Features
Supply Voltage
External Power
10..30 VDC
Host Power
5 VDC ±10%
Power Consumption
External Power
max. 10 W (charging) *
Host Power
max. 500 mA (charging)
Indicators
Ext. Power/Data yellow LED
Host Power/Data yellow LED
Reader batt. state green/red LED
Spare batt. state green/red LED (BC-8060 only)
beeper
Time of Recharge
External Power
max. 4 hours with 2150 mAh Li-Ion battery
Host Power
max. 10 hours with 2150 mAh Li-Ion battery
Radio Features
European Models
USA Models
Radio frequency
433.92 MHz
910 MHz
Bit Rate
19200 baud
36800 baud
Range (in open air)
50 m
30 m
Environmental Features
Working Temperature
Radio
-20° to +50 °C / -4° to +122 °F
Battery Charging
0° to +40 °C / +32° to +104 °F
Storage Temperature
-20° to +70 °C / -to +158 °F
Humidity
90 % non condensing
Protection Class
IP40
Mechanical Features
Weight without mounting base
about 380 g / 13.4 oz
Dimensions (without antenna)
240 x 108 x 95 mm / 9.44 x 4.25 x 3.74 in
Material
ABS
* Having a switching regulator inside, the BC-80X0 draws the same power, regardless of
the supply voltage. i.e. as the input voltage increases the current drawn decreases.
System Configuration
BC-80X0
STARGATE™
Max number of devices per base
station
32
255
Max number of devices in the
same reading area
2000
BC-8060
STARGATE™
Max number of base stations in
network
16 (including cradle Master)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Datalogic STARGATE specificazione

Tipo
specificazione
Questo manuale è adatto anche per

in altre lingue