Datalogic PowerScan M8500 Quick Reference Manual

Categoria
Lettori di codici a barre
Tipo
Quick Reference Manual
PowerScan™ M8500 Readers
Industrial Handheld Area Imager
Bar Code Reader with
Datalogic’s STAR Cordless System™
Quick Reference Guide
Datalogic ADC, Inc.
959 Terry Street
Eugene, OR 97402
USA
Telephone: (541) 683-5700
Fax: (541) 345-7140
©2009-2013 Datalogic, Inc.
An Unpublished Work - All rights reserved. No part of the contents of this docu-
mentation or the procedures described therein may be reproduced or transmitted
in any form or by any means without prior written permission of Datalogic ADC,
Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic ADC). Owners of Data-
logic products are hereby granted a non-exclusive, revocable license to reproduce
and transmit this documentation for the purchaser's own internal business pur-
poses. Purchaser shall not remove or alter any proprietary notices, including copy-
right notices, contained in this documentation and shall ensure that all notices
appear on any reproductions of the documentation.
Should future revisions of this manual be published, you can acquire printed ver-
sions by contacting your Datalogic representative. Electronic versions may either
be downloadable from the Datalogic website (www.datalogic.com) or provided on
appropriate media. If you visit our website and would like to make comments or
suggestions about this or other Datalogic publications, please let us know via the
"Contact Datalogic" page.
Disclaimer
Datalogic has taken reasonable measures to provide information in this manual
that is complete and accurate, however, Datalogic reserves the right to change any
specification at any time without prior notice.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in
many countries, including the U.S.A. and the E.U. All other brand and product
names may be trademarks of their respective owners.
Patents
This product may be covered by one or more of the following patents:
Design Pat. AU 310201; AU 310202; CN 693980; CN735959; HK 0602013.5M001; HK
0602013.5M002; JP 1305693; KR 30-0460940; US D570,843 S; USD588,596 S.
US Pat. 5,992,740; 6,305,606 B1; 6,517,003; 6,808,114 B1; 6,997,385 B2; 7,387,246 B2;
5,367,151; 5,449,893; 5,545,889; 6,098,877; 6,220,514 B1; 6,412,698 B2; 6,607,132 B1;
6,817,529 B2; 6,834,805 B2; 7,948,214 B2.
European Pat. 789,315 B1; 895,175 B1; 1,128,314 B1; 1,128,315 B1; 1,396,811 B1;
1,413,971 B1; 1,816,585 B1; 1,942,442 B1.
Additional patents pending.
Table of Contents
PowerScan™ M8500 Family ............................................................ 1
Description .....................................................................................................1
Using the PowerScan™ PM8500 Family ...............................................2
Indicators ........................................................................................................3
LED Indicators .......................................................................................3
Beeper......................................................................................................3
Good Read Spot ...................................................................................3
Charging the Batteries ...............................................................................4
Setup ................................................................................................................6
PowerScan™ M8500 Configuration .......................................................7
PowerScan™ M8500/BC-80X0 Point-to-Point Setup...............7
PowerScan™ M8500/BC-80X0 Stand Alone Setup...................8
Using Multiple Readers with Same Cradle................................11
PowerScan™ M8500/STAR-MODEM™ Stand Alone Setup ..11
PowerScan™ M8500/STAR-SYSTEM™ Setup.............................12
Default Configuration ..............................................................................15
Operating Test ............................................................................................16
Technical Features ....................................................................................17
Services and Support ...............................................................................22
Regulatory Information ...........................................................................23
Compliance..........................................................................................23
FCC Compliance.................................................................................23
Radio Compliance..............................................................................23
IC (Industry Canada)..........................................................................23
Power Supply ......................................................................................24
Laser Safety ..........................................................................................28
WEEE Compliance..............................................................................32
Datalogic ADC Limited Factory Warranty.................................33
Numeric Table .............................................................................................36
NOTES
Quick Reference Guide 1
PowerScan™ M8500 Family
Description
The PowerScan™ M8500 series readers can be used with either a BC-80X0 cradle
or Stargate™ radio base station to build a Cordless Reading System for the collec-
tion, decoding and transmission of bar coded data. The M8500 series can be used
in the same environment where M8300 series readers are already installed.
This manual includes just the commands required for the startup of the scanner
and setting of the interface. For complete configuration of the scanner, refer to the
PowerScan™ PM8500 Reference Manual or the Datalogic Aladdin configuration
program, both downloadable from the website and available on the included CD
ROM.
The PowerScan™ PM8500 Hand-Held Reader packs a lot of performance into
an attractive, rugged, hand-held device. It operates in commercial and industrial
environments, as well as the front office
.
Omni-
Directional
Operating
To read a symbol or capture an image, you simply aim the reader
and pull the trigger. Since the PowerScan™ PM8500 is a powerful
omni-directional reader, the orientation of the symbol is not
important.
Decoding
Thanks to powerful algorithms, PowerScan™ PM8500 reliably
decodes all major 1D (linear) bar codes, 2D stacked codes (such as
PDF417), 2D matrix symbols (such as DataMatrix), postal codes (such
as POSTNET, PLANET). The data stream — acquired from decoding a
symbol — is rapidly sent to the host. The reader is immediately
available to read another symbol.
Formatting and
Concatenating
The string of a decoded code may be processed according to
either a simple or advanced data formatting and be concatenated
to other codes (up to 4 different codes).
Autoscanning
An autoscan command causes the reader to scan continuously and
to monitor the central zone of its reading area.
Flash Memory
Flash technology allows you to upgrade the PowerScan™ PM8500
reader as new symbologies are supported or as improved
decoding algorithms become available.
USA Driver
License Parsing
The reader can be set up to select and output a subset of data
elements from USA Driver License PDF417 bar codes. This feature
can be enabled using either Datalogic Aladdin™ or the bar codes in
the USA Driver License Parsing Quick Reference Guide (QRG),
available on the Datalogic website.
The Powerscan M8500 is compatible with BC80x0 v3.0.0.00 (available in
the Aladdin Software on the CD included with this product) and later
releases. If a previous firmware version is installed in your BC80x0, please
upgrade to the latest version before installing the M8500.
Using the PowerScan™ PM8500 Family
2PowerScan M8500
Using the PowerScan™ PM8500 Family
The PowerScan™ PM8500 normally functions by capturing and decoding codes.
The PowerScan™ PM8500 reader uses an intelligent aiming system. By pulling
the trigger, the aiming system indicates a field of view, which should be positioned
over the code:
Aiming System
When you pull the trigger, a red beam illuminates the code. If the aiming system
is centered and the entire symbology is within the aiming system, you will get a
good read. The field of view changes size as you move the reader closer or farther
away from the code.
Relative Size and Location of Aiming System Pattern
Successful reading is signaled by an audible tone plus a good-read green LED.
The PowerScan™ PM8500 handheld reader aiming system is designed for
general reading and decoding of 1D and 2D symbols. Some variation in
reading distance will occur due to narrow bar width and other factors.
If reading codes positioned on reflective surfaces, it may be necessary to
tilt the reader with respect to the bar code and/or set the Camera Control
parameters. For configuring the Camera Control parameters refer to the
PowerScan™ PM8500 Product Reference Guide (PRG) available on the
website and the CD.
Linear bar code
2D Matrix symbol
Indicators
Quick Reference Guide 3
Indicators
LED Indicators
The PowerScan™ PM8500 family uses green LED indicators to signal the follow-
ing reader functions:
Beeper
The PowerScan™ PM8500 basic software provides beeper signals for good/wrong
reading and for indicating errors. Its tone, volume and duration can be directly
configured by using the codes given in the PowerScan™ PM8500 Product Refer-
ence Guide (PRG) available on the website.
The application program can also manage the beeper (User Defined Beeper) when
the reader is controlled by a Host PC. It is possible to activate the beeper by send-
ing a command from the Host to the reader via the current communication inter-
face.
Good Read Spot
A green good read spot will be projected in the field of view when the reading is
successful.
STATUS BEHAVIOR
Power ON At power-on, the LEDs blink briefly, then light up for 2
seconds to signal the power supply is present.
Normal Function The LED lights up after a good decoding and will
switch off only at the next trigger press.
Charging the Batteries
4PowerScan M8500
Charging the Batteries
Once the BC-80X0/C-8000 is powered, you can charge the reader's batteries.
Place the PowerScan™ M8500 into the BC-80X0 cradle or the C-8000 battery
charger. The "Reader" LED on the cradle/battery charger turns red.
The battery is completely charged when the "Reader" LED on the cradle/battery
charger turns green.
To change the battery, push the Release Button as indicated by Arrow 1 and
extract the battery pack from the reader handle. Then, insert the new battery pack
into the reader handle until a ‘clickis heard and the Release Button moves back to
its neutral position.
1
2
Charging the Batteries
Quick Reference Guide 5
As with other types of batteries, Lithium-Ion (LI) batteries will lose capacity over time. Capacity deteri-
oration is noticeable after one year of service whether the battery is in use or not. It is difficult to pre-
cisely predict the finite life of a LI battery, but cell manufacturers rate them at 500 charge cycles. In
other words, the batteries should be expected to take 500 full discharge/charge cycles before needing
replacement. This number is higher if partial discharging / recharging is adhered to rather than full /
deep discharging,
The typical manufacturer advertised useful life of LI batteries is one to three years, depending on
usage and number of charges, etc., after which they should be removed from service, especially in mis-
sion critical applications. Do not continue to use a battery that is showing excessive loss of capacity, it
should be properly recycled / disposed of and replaced. For most applications, batteries should be
replaced after one year of service to maintain customer satisfaction and minimize safety concerns.
Collect and recycle waste batteries separately from the device in compliance with European Directive
2006/66/EC, 2011/65/EU, 2012/19/EU. and subsequent modifications, US and China regulatory and oth-
ers laws and regulations about the environment.
WARNING
Do not discharge the battery using any device except for the scanner.
When the battery is used in devices other than the designated product, it
may damage the battery or reduce its life expectancy. If the device causes
an abnormal current to flow, it may cause the battery to become hot,
explode or ignite and cause serious injury.
Lithium-ion battery packs may get hot, explode or ignite and cause seri-
ous injury if exposed to abusive conditions. Be sure to follow the safety
warnings listed below:
• Do not place the battery pack in fire or heat.
Do not connect the positive terminal and negative terminal of the battery pack
to each other with any metal object (such as wire).
• Do not carry or store the battery pack together with metal objects.
• Do not pierce the battery pack with nails, strike it with a hammer, step on it or
otherwise subject it to strong impacts or shocks.
• Do not solder directly onto the battery pack.
• Do not expose the battery pack to liquids, or allow the battery to get wet.
• Do not apply voltages to the battery pack contacts.
In the event the battery pack leaks and the fluid gets into your eye, do not
rub the eye. Rinse well with water and immediately seek medical care. If
left untreated, the battery fluid could cause damage to the eye.
CAUTION
Always charge the battery at 32° – 104°F (0° - 40°C) temperature range.
Use only the authorized power supplies, battery pack, chargers, and
docks supplied by your Datalogic reseller. The use of any other power
supplies can damage the device and void your warranty.
Do not disassemble or modify the battery. The battery contains safety
and protection devices, which, if damaged, may cause the battery to
generate heat, explode or ignite.
Do not place the battery in or near fire, on stoves or other high tempera-
ture locations.
Do not place the battery in direct sunlight, or use or store the battery
inside cars in hot weather. Doing so may cause the battery to generate
heat, explode or ignite. Using the battery in this manner may also result
in a loss of performance and a shortened life expectancy.
Do not place the battery in microwave ovens, high-pressure containers
or on induction cookware.
Immediately discontinue use of the battery if, while using, charging or
storing the battery, the battery emits an unusual smell, feels hot,
changes color or shape, or appears abnormal in any other way.
Do not replace the battery pack when the device is turned on.
Do not remove or damage the battery packs label.
Do not use the battery pack if it is damaged in any part.
Battery pack usage by children should be supervised.
Setup
6PowerScan M8500
Setup
PowerScan™ M8500/BC-80X0 Point-to Point Configuration
1. Connect a BC-80X0 cradle to the Host. For installation and connection
information see the BC-80X0 Quick Reference Manual.
2. Charge the PowerScan™ M8500 battery using an BC-80X0 or the
C-8000 char
ger as described in this Quick Reference manual. A full
charge takes 4 hours if using an external power supply; while it takes up
to 10 hours if supplying power through the USB port.
3. Configure the reader as described in this Quick Reference -
PowerScan™ M8500/BC-80X0 Point-to-Point Setup.
4. Configure the BC-80X0 cradle. See BC-80X0 Configuration in the BC-
80X0 Quick Reference.
or
PowerScan™ M8500/BC-80X0 Stand Alone Configuration
1. Connect an BC-80X0 cradle to the Host. For installation and connection
information see the BC-80X0 Quick Reference Manual.
2. Charge the PowerScan™ M8500 battery using an BC-80X0 or the
C-8000 char
ger as described in this Quick Reference manual. A full
charge takes 4 hours if using an external power supply; while it takes up
to 10 hours if supplying power through the USB port.
3. Configure the reader as described in this Quick Reference -
PowerScan™ M8500/BC-80X0 Stand Alone Setup.
4. Configure the BC-80X0 cradle. See BC-80X0 Configuration in the
BC-80X0 Quick Reference.
or
PowerScan™ M8500/STAR-System™ Configuration
1. Charge the PowerScan™ M8500 battery using an BC-8000 or the
C-8000 charger as described in this Quick Reference manual. A full
charge takes 4 hours if using an external power supply; while it takes up
to 10 hours if supplying power through the USB port.
2. Configure the reader as described in this Quick Reference -
P
owerScan™ M8500/STAR-System™ Setup.
PowerScan™ M8500 Configuration
Quick Reference Guide 7
PowerScan™ M8500 Configuration
PowerScan
M8500/BC-80X0 Point-to-Point Setup
A rapid configuration procedure has been devised for point-to-point applications
where a single reader is associated exclusively with its own BC-80X0 base station
and where it is not necessary to set the Date and Time parameters.
A special pre-printed bind-address label provided in the BC-80X0 base station
package can be used to bind the PowerScan™ M8500 reader to the base station
with the address coded on the label. The address is also written numerically on the
label to be easily recognized. Valid addresses are in the range from 0000 to 1999.
Make sure that all cradles used in the same area have different addresses.
To rapidly configure your point-to-point application:
1. Apply the bind-address label onto the
BC-80X0 base station as indicated
in the BC-80X0 Quick Reference Manual.
2. When the BC-80X0 cradle is connected
and powered, read the Bind-
Address label to pair the PowerScan™ M8500 to the BC-80X0 cradle.
The green LED on the PowerScan™ M8500 will blink: the reader is ready
to be positioned onto the cradle.
3. Firmly position the reader onto the cradle within 10 seconds, a beep will
be emitted, signaling that the BC-80X0 cradle has been paired to the
PowerScan™ M8500, and the green LED on the reader will go off.
4. Configure the BC-80X0 cradle, refer to the “BC-80X0 Quick Reference”.
END of procedure. YOUR READER IS NOW READY TO READ CODES.
If it ever becomes necessary to
change
the reader, just read the
bind-address label applied to the
cradle and position the new reader
onto the cradle.
Do not use multiple readers with
this configuration method.
Green LED
PowerScan™ M8500 Configuration
8PowerScan M8500
PowerScan™ M8500/BC-80X0 Stand Alone Setup
When the BC-80X0 cradle is connected and powered, configure the PowerScan™
M8500 by reading the following codes in the given sequence and follow the instruc-
tions.
For the numeric code selection of steps 3, 4, and 5 use the table at the end
of this Quick Reference
1. Restore PowerScan™ M8500 Default
2. Enter Configuration
3. Set Date
+
six digits for Day, Month and Year (DDMMYY).
4. Set Time
PowerScan™ M8500 Configuration
Quick Reference Guide 9
+
four digits for Hours and Minutes (HHMM).
5. Set Radio Address
+
four digits for the PowerScan™ M8500 Address
(from 0000 to 1999).
All readers used in the same area must have different addresses.
6. Exit and Save Configuration
7. Read the Bind code to pair the PowerScan™ M8500 to the BC-80X0 cradle.
The reader is dedicated to the cradle. Any previously bound reader will be
excluded.
To connect several readers to the same cradle see the following section "Using
Multiple Readers with Same Cradle".
Bind
The green LED on the PowerScan™ M8500 will blink: the reader is ready to be
positioned onto the cradle.
8. Firmly position the reader onto the cradle within 10 seconds, a beep will be
emitted, signaling that the BC-80X0 cradle has been paired to the
PowerScan™ M8500, and the green LED on the reader will go off.
PowerScan™ M8500 Configuration
10 PowerScan™ M8500
END of procedure. YOUR READER IS NOW READY TO READ CODES.
9. Configure the BC-80X0 cradle, refer to the “BC-80X0 Quick Reference”.
Green LED
PowerScan™ M8500 Configuration
Quick Reference Guide 11
Using Multiple Readers with Same Cradle
If you want to use several readers associated with the same cradle, you must first
Bind the cradle with one of the readers (see previously described configuration
procedure).
Successive readers can be associated with the same cradle by following the con-
figuration procedure substituting the Bind command with Join.
END of procedure.
PowerScan
M8500/STAR-MODEM™ Stand Alone Setup
To configure a PowerScan™ M8500 reader to communicate with STAR-
Modem™ in Stand Alone Mode, follow the "PowerScan™ M8500/BC-80X0
Stand Alone Setup" procedure substituting steps 5 and 6 with those below:
END of procedure. YOUR READER IS NOW READY TO READ CODES.
7. Join
The g
reen LED on the PowerScan™ M8500 will blink: the reader is ready to be
positioned onto the cradle. Complete step 8.
CAUTION
All readers associated with the same cradle must have different
addresses.
6. STAR-Modem™ Address
Read the code above and the four-digit address of the STAR-Modem™.
7. Exit and Save Configuration
PowerScan™ M8500 Configuration
12 PowerScan™ M8500
PowerScan
M8500/STAR-SYSTEM™ Setup
The following procedure allows configuring a PowerScan™ M8500 reader to
communicate with various STAR-System™ devices such as Stargate™ RF base
stations:
1. Restore PowerScan™ M8500 Default
2. Enter Configuration
3. Set Date
+
six digits for Day, Month and Year (DDMMYY).
4. Set Time
+
four digits for Hours and Minutes (HHMM).
PowerScan™ M8500 Configuration
Quick Reference Guide 13
5. Set the connection according to the length of the codes to be read:
Code Length 240 Characters
Code Length 240 Characters
(not for systems with BC-80X0 as Master)
6. Set Radio Address
+
four digits from the Numeric Table for the PowerScan™ M8500 Address
(from 0000 to 1999).
All readers used in the same area must have different addresses.
7. Set First STAR-System™ Address
+
four digits from the Numeric Table in the range 0000 to 1999
PowerScan™ M8500 Configuration
14 PowerScan™ M8500
END of procedure. YOUR READER IS NOW READY TO READ CODES.
8. Set Last STAR-System™ Address
+
four digits from the Numeric Table in the range 0000 to 1999
Whenever the system is composed of a single base station, the first
and last base station addresses (steps 7 and 8) must have the same
value.
9. Exit and Save Configuration
Default Configuration
Quick Reference Guide 15
Default Configuration
DATA FORMAT – Symbology Dependent Parameters
symbology specific format = select all, no headers, no terminators, symbology character
substitution disabled, symbology character deletion disabled
DATA FORMAT – Concatenation
Concatenation disabled, 2 EAN/UPC codes concatenated, Set First Concatenated Code
Length 000 = any length, Set Second Concatenated Code Length 000 = any length, Set
Third Concatenated Code Length 000 = any length, Set Fourth Concatenated Code Length
000 = any length, Concatenation with Intercode Delay disabled, Concatenation Timeout 10
seconds, Concatenation Failure Transmission = Tx codes causing failure, Transmission after
Timeout = No code transmission, Concatenation Result Code ID = No code Identifier
ADVANCED FORMATTING PARAMETERS
format disabled
CAMERA CONTROL
exposure mode = automatic, based on entire image
CODE SELECTION
issue identical codes = enable
enabled codes
Standard Code 39: no check digit control, variable code length;
EAN 8/EAN 13 / UPC A/UPC E without ADD ON
: UPCE expansion disabled
Code 128
: variable code length
PDF417
Datamatrix: rectangular, normal and inverted, variable code length
QR
disabled codes
Code 32, Interleaved 2/5, Codabar, Code 93, EAN 128, GS1 DataBar™, Micro PDF417, Postal
Codes, Maxicode, Composite Codes
,
Aztec, microQR, IMB.
READING PARAMETERS
trigger type normal, trigger level mode, flash on = 2 sec, flash off = 2 sec, beeper tone =
tone 1, beeper volume = high, beeper duration = 50 ms, user defined beeper = tone 1, user
defined beeper volume = high, user defined beeper duration = 100 ms, code per scan = one
code per scan, read per cycle = one read per cycle, scan timeout = 5 sec, central code
transmission = disabled, order by code length = disabled, order by code symbology =
disabled, autoscan mode = disabled, autoscan aiming system = enabled, autoscan
hardware trigger = enabled, autoscan illumination system = disabled, stand autoscan mode
= normal, aiming system delay = disabled, good read spot = short, safety time = 500 ms
RADIO PARAMETERS
radio protocol timeout = 2 seconds, power-off timeout = 4 hours, transmission mode =
one-way, beeper control for radio response = normal, single store = disabled, batch mode =
disabled, find me = enabled, radio RX timeout = disabled
Operating Test
16 PowerScan™ M8500
Operating Test
EAN-13 Code 39 (Standard)
Code 128
PDF417
QR
Data Matrix (Normal)
1 234567 000992
17162
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Datalogic PowerScan M8500 Quick Reference Manual

Categoria
Lettori di codici a barre
Tipo
Quick Reference Manual

in altre lingue