INSTRUCTION MANUAL FOR WIRE WELDING MACHINE
IMPORTANT: BEFORE STARTING THE EQUIPMENT,
READ THE CONTENTS OF THIS MANUAL, WHICH MUST
BE STORED IN A PLACE FAMILIAR TO ALL USERS FOR
THE ENTIRE OPERATIVE LIFE-SPAN OF THE MACHINE.
THIS EQUIPMENT MUST BE USED SOLELY FOR WEL-
DING OPERATIONS.
1 SAFETY PRECAUTIONS
WELDING AND ARC CUTTING CAN BE
HARMFUL TO YOURSELF AND OTHERS. The
user must therefore be educated against the hazards,
summarized below, deriving from welding operations.
For more detailed information, order the manual code
3.300.758
ELECTRIC AND MAGNETIC FIELDS - May be dangerous.
· Electric current following through any con-
ductor causes localized Electric and Ma-
gnetic Fields (EMF). Welding/cutting current
createsEMFeldsaroundcablesandpo-
wer sources.
·Themagneticeldscreatedbyhighcurrentsmayaffect
the operation of pacemakers. Wearers of vital electronic
equipment (pacemakers) shall consult their physician be-
fore beginning any arc welding, cutting, gouging or spot
welding operations.
· Exposure to EMF elds in welding/cutting may have
other health effects which are now not known.
· All operators should use the followingprocedures in or-
dertominimizeexposuretoEMFeldsfromthewelding/
cutting circuit:
- Route the electrode and work cables together
- Secure them with tape when possible.
- Never coil the electrode/torch lead around your body.
- Do not place your body between the electrode/torch
lead and work cables. If the electrode/torch lead
cable is on your right side, the work cable should also
be on your right side.
- Connect the work cable to the workpiece as close as
possible to the area being welded/cut.
- Do not work next to welding/cutting power source.
EXPLOSIONS
Do not weld in the vicinity of containers under
pressure, or in the presence of explosive dust, gases
or fumes.
All cylinders and pressure regulators used in welding ope-
rations should be handled with care.
ELECTROMAGNETIC COMPATIBILITY.
This machine is manufactured in compliance with the in-
structions contained in the standard IEC 60974-10 (CL.
A), and must be used solely for professional purposes in
anindustrialenvironment.There maybe potential dif-
culties in ensuring electromagnetic compatibility in non-
industrial environments.
H.F FREQUENCY
• High frequency (H.F.) can interfere with radio
navigation, safety services, computers, and com-
munications equipment
• Have only qualied persons familiar with electronic
equipment perform this installation.
• Theuserisresponsibleforhavingaqualiedelectrician
promptly correct any interference problem resulting
from the installation.
• IfnotiedbytheFCCaboutinterference,stopusingthe
equipment at once.
Have the installation regularly checked and maintained.
Keep high-frequency source doors and panels tight-
ly shut, keep spark gaps at correct setting, and use
grounding and shielding to minimize the possibility of
interference.
DISPOSAL OF ELECTRICAL AND ELECTRONIC
EQUIPMENT.
Do not dispose of electrical equipment together
with normal waste!In observance of European
Directive 2002/96/EC on Waste Electrical and Electronic
Equipment and its implementation in accordance with
national law, electrical equipment that has reached the
end of its life must be collected separately and returned
to an environmentally compatible recycling facility. As the
owner of the equipment, you should get information on
approved collection systems from our local representati-
ve. By applying this European Directive you will improve
theenvironmentandhumanhealth!
IN CASE OF MALFUNCTIONS, REQUEST ASSISTANCE
FROM QUALIFIED PERSONNEL.
1.1 WARNING LABEL
The following numbered text corresponds to the label
numbered boxes.
B. Driverollscaninjurengers.
C. Welding wire and drive parts are at welding voltage
during operation-keep hands and metal objects away.
1 Electric shock from welding electrode or wiring can
kill.
1.1 Wear dry insulating gloves. Do not touch electrode
with bare hand. Do not wear wet or damaged gloves.
1.2 Protect yourself from electric shock by insulating
yourself from work and ground.
1.3 Disconnect input plug or power before working on
machine.
2 Breathing welding fumes can be hazardous to your
health.
2.1 Keep your head out of fumes.
2.2 Use forced ventilation or local exhaust to remove
fumes.
2.3 Use ventilating fan to remove fumes.
3 Weldingsparkscancauseexplosionorre.
3.1Keepammablematerialsawayfromwelding.
3.2Weldingsparkscancauseres.Haveareextingui-
sher nearby and have a watchperson ready to use it.
3.3 Do not weld on drums or any closed containers.
4 Arc rays can burn eyes and injure skin.
4.1 Wear hat and safety glasses. Use ear protection and
button shirt collar. Use welding helmet with correct
shadeoflter.Wearcompletebodyprotection.
11
5 Become trained and read the instructions before
working on the machine or welding.
6 Do not remove or paint over (cover) label.
2 GENERAL DESCRIPTIONS
2.1 SPECIFICATIONS
The Sound 2060/MD Star Double Pulse is an equipment
suitable for synergic pulsed MIG/MAG, synergic not
pulsed MIG/MAG and conventional MIG/NAG welding,
developed with inverter technology. The power source is
equipped with a 2-roller wire feeder.
This welding machine must not be used to defrost pipes.
2.2 EXPLANATION OF TECHNICAL SPECIFICATIONS
This machine is manufactured according to the following
standards: IEC 60974.1 / IEC 60974.10 (CL. A) /
IEC 61000-3-11 / IEC 61000-3-12.
N°. Serial number. Must be indicated on any
request regarding the welding machine.
Single-phase static transformer-rectier
frequency converter.
MIG Suitable for MIG-MAG welding.
U0. Secondary open-circuit voltage.
X. Duty cycle percentage. The duty cycle
expresses the percentage of 10 minutes
during which the welding machine may run
at a certain current without overheating.
I2. Welding current
U2. Secondary voltage with current I2
U1. Rated supply voltage
1~ 50/60Hz 50- or 60-Hz single-phase power supply.
I1 Max Max. absorbed current at the corresponding
current I2 and voltage U2.
I1 eff This is the maximum value of the actual
current absorbed, considering the duty
cycle. This value usually corresponds to the
capacity of the fuse (delayed type) to be used
as a protection for the equipment.
IP23S Protection rating for the housing.
Grade 3 as the second digit means that
this equipment may be stored, but it is not
suitable for use outdoors in the rain, unless
it is protected.
S
Suitable for use in high-risk environments.
NOTE: The welding machine has also been designed for use
in environments with a pollution rating of 3. (See IEC 60664).
2.3 PROTECTIONS
2.3.1 Block protection
In the event of a malfunction, a ashing number may
appear on the display AM, with the following meaning:
52 = Start button pressed during start-up.
53 = start button pressed during thermostat reset.
56 = Extended short-circuit between the welding
electrode and the material to be welded.
Shut the machine off and turn it back on. If different
numbers appear on the display, contact technical service.
2.3.2 Overload cut-out
This machine is protected by a thermostat, which prevents
the machine from operating if the allowable temperatures
are exceeded. In these conditions the fan continues to
operate and the display AM ashestheabbreviation“tH.”
3 DESCRIPTION OF POWER SOURCE (Fig. 1)
A – Socket (-): this is where the earth cable is to be
connected.
B Central adapter : Connect the welding torch.
B1 – Central adapter.
This is where the welding torch or the Push-Pull system
torch Art. 2003/2009 is to be connected.
C Connector : For connecting remote controls and the
welding control cable Push–Pull Art. 2003/2009.
D - Selector switch:
Central adapter B1 is operated by selecting position (
) with the selector switch knob, on the contrary, by
selecting position ( ) central adapter B is operated.
F - Connector : Connector type DB9 (RS232 serial line) to
use for updating the microprocessor programs.
L - ON/OFF switch.
M – Power cable.
N – Gas hoses.
O - Fuse holder.
P - Power supply socket.
Q - Pressure switch socket .
12
4 DESCRIPTION OF CONTROL PANEL (Fig. 2)
AE selection key.
Each brief pressure selects the size, adjustable via the
AI knob. The sizes which can be selected are shown by
LEDs AA/AB/AC/AD.
LED AA PRG.
Indicates that the display AL shows the set program
number.
LED AB Thickness.
TheAL display shows the recommended thickness based
on the set current and wire speed. Active only in synergic
MIG processes.
LED AC Wire speed.
Indicates that the display AL shows the wire speed in
welding.
LED AD Current.
Indicates that the display AL shows a welding current.
During welding always shows the measured current; with
the machine at a standstill, if AG is OFF, shows the set
current.
LED AF - Globular position.
May not be selected. Active in synergic MIG process.
When lit, this signals that the pair of values chosen for
welding may give unstable arcs and splatters.
LED AG - Hold.
May not be selected. It signals that the values shown on
the displays AL and AM (normally Amperes and Volts) are
those used during last welding. Activated at the end of
each welding session.
LED AH - Voltage.
In all welding processes, it indicates that the display AM
shows the re-set welding voltage or, if in combination with
LED AG lit, the last measured voltage.
Knob AI.
The following values are set: welding current A, wire speed
(
), thickness ( ), program number PRG. In the service
functions the following are selected: TRG, SP, HSA, CrA,
PrF, PoF, Acc, bb, L, Dp, PPF, Ito, Fac.
In MIG synergic processes when a value is adjusted the
other values are adjusted as well. All these values are
shown on the display AL.
Knob AN.
The following sizes are set:
In synergic MIG the arc length, in conventional MIG the
welding voltage.
Inside the service menu, according to the value set
by knob AI it selects the set value, the activation or
desactivation of the same, or an additional selection to be
made inside the fuction.
B1
C
A
F
B
O
L
P
Q
M
D
N
Fig. 1
13
Display AL.
In all welding processes, it numerically displays the
selections made via the selection key AE and adjusted
via the knob AI.
For the welding current (LED AD) it displays the amperes.
For the wire speed (LED AC) it displays the meters per
minute.
For the thickness (LED AB) it displays the millimeters.
For (LED AA) it displays the set program number.
In the service functions the following are selected: TRG,
SP, HSA, CrA, PrF, PoF, Acc, bb, L, Dp, PPF, Ito, Fac.
For the parameters within the service functions that are
shown on the display AM, see the paragraph on service
functions.
When the machine is in the warning mode, it displays
aashingwarning(exemple:OPN if the lateral panel is
open. When the machine is in the error mode it displays
Err.
Display AM.
Displays by the number: in synergic MIG the arc length
and in conventional MIG the welding voltage.
For the welding voltage (LED AH) it displays the Volts. For
the arc length (LED AHoff) it displays a number between
9.9 and +9.9, 0 being the recommened value.
For the parameters in the MIG service function, that are
shown on the display AM, see the paragraph on service
functions .
When the machine is in error mode it displays the
corresponding error code between 1 and 99.
Selection key AO.
Each time this key is pressed, the selected process is
shown by LED AP/AQ/AR.
LED AP Pulsed MIG.
Shows that the selected process is the synergic MIG
Pulsed.
LED AQ SYNERGIC MIG.
Shows that the selected process is synergic MIG.
LED AR CONVENTIONAL MIG.
Shows that the selected process is conventional MIG.
Selection key AU.
Each brief pressure selects 2 stages mode (MANUAL) and
the 4 stages mode (AUTOMATIC), the selection is shown
on the display AL.
In the 2 stages mode the machine begins welding when
the welding torch trigger is pressed, and stops when
released.
In the 4 stages mode to begin welding press and release
the welding torch trigger; to interrupt, you must press and
release it again.
Selection key AV. (JOB)
Saving and restoring of the stored processes.
To save a working condition (JOB), just hold down for at
least 3 seconds the key AV, the LED AZ glows, on the
display AL the abbreviation STOashesandondisplay
AM the number of the rst available position ashes.
Knob AN is used to select the saving position; press again
key AV untilasoundwillconrmthatithasbeensaved
andtheselectednumberstopsashing.
TorestorethesavednumberjustbrieypresskeyAV and
restore the number by means of knob AN. Up to 99 pairs
od current/voltage values may be saved.
AA
AI
AO AP AQ AR AU AV AZ AY AW
AB AC AD AE AFAL AG AH AM AN
Fig. 2
14
To delete a saved number, press for at least 3 seconds
key AV, turn knob AI until the display ALshows the
abbreviation DEL and press the key againAV for 3 more
seconds.
A current/voltage parameter may be restored outside
saving for both using or changing it. To restore it press
for 3 seconds key AV, display by menas of knob AI the
number to be restored and show on display AL, with
knobANthe abbreviation rcL; now just press for at least
3 seconds key AV.
LED AZ JOB.
Shows that you are inside the saving menu of the saved
working points.
Selection key AY.
Gas Test .
Whenthisjeyispressedgasstarsowing;tostopitpress
the key again.
If the second press does not takes place the gas output
is interrupted after 30 seconds
Selection key AW.
Wire test.
Allows the wire feed with no current or voltage present.
Whenthiskey is helddown,during the rst5seconds
the wire advances at the speed of 1 meter per minute and
then the speed increases up to 8 meters per minute.
When this key is released the motor stops immediately.
5. SERVICE FUNCTIONS.
Press the key AE, and hold it down for at least 3 seconds
to enter the submenu. Turning the knob AI you select the
function, shown on the display ALand turning the knob
AN you select the type of operation or the value, shown
on the display AM. To return to the normal display, press
and release the key AE immediately.
1- H2O (Cooling unit, optional).
Turning the knob AN you select the type of operation:
OFF = shut off, ON C = always on, ON A = automatic
start-up.
When the automatic mode is selected the pump begins
working immediately at each welding start command and
stops 3 minutes after the welding is completed.
At each power source start-up a short pump test takes
places for15 seconds. If an insufcient presssure is
detected the machine goes into warning mode and H2O
ashesondisplayAM.
If th elow pressure condition persists for more than 30
seconds, the pump is disactivated and the machine goes
to error mode (ERR 75).
2- TRG.
Choice between 2- or 4- stages , 3 levels, the selection
2t and 4t with the selection key AU, without entering the
service functions.
2t the machine begins welding when the welding torch
trigger is pressed, and stops when released. 4t to begin
welding press and release the welding torch trigger; to
interrupt, you must press and release it again. 3L this
procedure is active in the synergic processes. Specially
well suited to weld aluminum.
3 currents are available that can be used in welding by
means of the welding torch start button. The current and
the slope values are set as follows:
SC starting current (Hot Start). With the possibility of
adjusting from 1 to 200% of the welding current, a value
adjusted using the knob AN.
Slo slope. Possibility of adjusting from 1 to 10 seconds.
DenestheconnectiontimebetweentherstcurrentSC
with the welding current and the second current with
the third current CrC (craterllercurrent),avaluesetby
means of knob AN.
CrC - «Crater ller» current. With the possibility of
adjusting from 1 to 200% of the welding current, a value
adjusted using the knob AN.
Welding starts at the welding torch button pressure, the
named pressure will be the starting pressure SC.
This current is kept as long as the welding torch button
is held down; when the welding torch trigger is released
therstcurrentconnectstotheweldingcurrent,setby
means of knob AI, and is kept as long as the welding
torch button is held down. When the welding torch trigger
is pressed again the welding current connects to the third
current CrC and is kept as long as the welding torch
trigger is held down. When the welding torch trigger is
released welding stops.
3- SP (spot-welding).
Off/ON activates and disables the spot function.
The spot welding time tSP is set from 0.3 to 5 seconds.
The interval between two spots tIN is set from 0,3 to 5
seconds.
This function is è blocked when function 3L is activated.
4- HSA (Automatic Hot Start).
This function is blocked when function 3L is activated
and works only with the synergic processes.
Once the function has been enabled using theAN knob ,
the operator may adjust the level of the starting current
SC (Hot Start), with the possibility of adjusting from 1 to
200% of the welding current, a value adjusted using the
knobAN .
The duration tHS (default 130%) of this current may also
be adjusted from 0.1 to 10 seconds.) (default 0,5 sec.).
The switching time Slo between the SC current and
the welding current may also be adjusted from 0.1 to 10
seconds.(default 0.5 seconds).
5- CrA (nal crater ller).
This function may be selected by means of key AI and is
working during welding 2t or 4t and also in combination
with function HSA, if so requested.
After activating function «On» by means of knob AN,
rotate knob AI to display the abbreviations:
Slo = Fitting time between the welding current and the
craterllingtime.Default0.5sec.
Range 0.1 – 10 seconds.
CrC = crater lling time expressed as a percentage of
the welding wire speed. Default 60%. Range from 10 to
200%.
TCr=durationofthellingcurrenttime.Default0.5sec.
Range 0.1 – 10 seconds.
15
6- PrF (Pre-gas).
The adjustment may range from 0 to 3 seconds.
7- Pof (post-gas).
The adjustment may range from 0 to 30 seconds.
8- Acc (soft-start ).
The adjustment may range from 0 to 100%.
It is the wire speed, expressed as a percentage of the
speed set for the welding, before the wire touches the
workpiece.
This adjustment is important in order to always achieve
good starts.
Manufacturersetting«Au»:automatic.
The value can be changed using the knob AN. If, once
changed, you wish to return to the original settings,
press the key AV until the abbreviation «Au» reappears on
the display AM.
9- BB (Burn-back).
The adjustment may range from 4 to 250ms. Serves to
adjust the length of the wire leaving the contact tip after
welding. The higher the number, the more the wire burns.
Manufacturer setting «Au»automatic.
If, once changed, you wish to return to the original settings,
press the key AV until the abbreviation «Au»reappearson
the display N.
10- L (impedance).
The adjustment may range from -9.9 to +9,9. Zero is the
number set by the manufacturer:if the number is negative,
the impedance decreases and the arc becomes harder; if
increased, it becomes softer.
11- dP ( Double pulse)
This type of welding varies the current intensity between
two levels and may be included in all synergic processes.
Before setting, it is necessary to make a short bead to
determine the speed closest to the type of welding that
you will be doing. This determines the reference speed.
To activate the function proceed as follows:
A)- Activate the function by turning knob AN until the
abbreviation On reappears on the display AM.
B)- Turn knob AI nounitltheabbreviationFdP reappears
(double pulse frequency) on the display AL. The display
AM reads the abbreviation OFF.
Turn the knobAN to select the working frequency
(adjustment from 0.5 to 5 Hz). The selected value is shown
on the display AM.
C) Turn knobAI until the abbreviation ddP (difference in
m/min of the double pulse) is displayed.
Turn the knob AN to select the meters per minute (range
from 0.1 to 3m/min) that will be added to and subtracted
from the reference speed (default 1m/min).
D)Turn the knob AI until the display shows the the
abbreviation tfP. This is the duration of the highest wire
speed, thus the highest current. It is expressed as a
percentage of the time gained from the Fdp frequency
(seegure3).
DdP= 0,1÷3 m/min
tdP T= 25÷75% di
T Fdp= 1/ (0,5÷5 Hz)
==
Reference
speed
Fig. 3
Turn knob AN to adjust the percentage. Range between
25 and 75% (default 50%).
E)-Turn knobAI unitl the display shows the abbreviationAdP
(arc length of the highest current). Range between -9.9
and 9.9% (default 0).
When welding, check that the arc length is the same for
both currents; turn the AN knob to correct it if necessary.
Note: it is possible to weld within the double pulse
functions.
Once these adjustments have been made, to return to the
controlpanelnormaldisplaybrieypresskeyAE.
Should it be necessary to adjust the arc length of the lowest
current/lowest speed, adjust the arc length of the reference
speed. When the reference speed moves, the previous
settings must also be repeated for the new speed.
12- PP (push-pull).
By using Push-Pull torch Art. 2003 function PPF (Push
Pull Force) is enabled which adjusts the drive torque of
the push-pull motor in order to make the wire feed linear.
The adjustment may range from 99 to -99 and is done
through knob AN.. Standard adjustment is 0.
13- Ito. (Inching time out.
The purpose is to stop the welding machine if the wire
owsafterstartingwithnopassageofcurrent.
The wire ow from the welding torch can be adjusted
from 5 to 50 centimeters by means of knob AN. When
this function is restored, it may be activated (On) or cut
off (Off).
14 - qC (Quality Control).
Enables Quality Control function.
Off- Function off.
On- Function on. (For this function please refer to
Manual 3300239 concerning Articles: 224.04 and
405.00).
qCO- (output Quality Control ).
Selects the output type of quality control reports:
ASC – (ASCII) serial output port, only unformatted text
for terminals of the Windows Hiperterminal kind.
PRN– (Printer) serial output port, for printer Art. 405.
15- UtC Time Zone Selection.
Specify a value from -12 to 12 depending on the country
where the welding machine will be used (e.g. Italy 1 = +1
h as against UTC)
16
16 - dSt Legal Time Selection.
(e.g. 0 Winter, 1 Summer)
17- Fac. (factory).
The purpose is to return the welding machine to the
original settings provided by the manufacturer. With the
function selected, the display AM shows noP = restores
the welding machine to the original settings disregarding
the stored programs, Prg = deletes all stored programs
and ALL = restores the welding machine to the original
settings.
To save the desired function press the button AV, the
abbreviation shown on the display AMwillbeginashing;
afterafewseconds,asoundwillconrmthatithasbeen
saved.
6 INSTALLATION
The welding machine must be installed by skilled
personnel. All connections must be made in full compliance
with current safety laws (See CEI 26-23 - IEC/TS 62081).
6.1 PLACEMENT
The weight of the welding machine is approximately 80 Kg.
Position the unit in an area that ensures good stability, and
efcientventilationsoastopreventmetaldust(grinding)
from entering.
6.2 ASSEMBLY
Mount the plug on the power cord, being especially
careful to connect the yellow/green conductor to the earth
pole. Make sure that the supply voltage corresponds to
the rated voltage of the welding machine.
Size the protective fuses based on the data listed on the
technicalspecicationsplate.
This welding machine has been designed to
contemporarily mount 2 welding torches and 2 coils of
wire having a diameter of 300mm; this machine cannot
weld with the 2 torches at the same time, the torch
selection is made by means of selector switch D.
The gas cylinder must be equipped with a pressure
regulator and a gauge. If the cylinder is placed on the
cylinder shelf of the trolley, it must be fastened using
the strap provided. Only after positioning the cylinder,
connect the outgoing gas hose from the rear panel of the
machine to the pressure regulator.
2 gas hoses leave the rear panel, one is used in
combination with central adapter B and the other one
with central adapter B1. In order to select the right
combination read the plate at its side.
Adjustthegasowtoapproximately8/10liters/minute
To make sure that the groove of the roller matches the
wire diameter used, open the mobile lateral side, remove
the cover CA, release the wire press roller by means of
the pressure adjusting knob BN, replace the roller and
remount the cover CA.(Seeg.4).
BN
CA
Fig. 4
Mount the wire coil and slip the wire into the feeder and
welding torch sheath.
Block the wire press roller with the knob BN and adjust
the pressure.
Turn on the machine.
Adjust the gas by means of key AY and then feed the wire
by means of key AW.
7 WELDING
Welding Synergic Pulsed MiG LED AP on.
Select the PRG number based on the wire diameter to be
used, the type and quality of the material, and the type of
gas, using the instructions located inside the wire feeder
compartment.
Set the functions in the submenu according to the
instructions under paragraph «Service functions».
5.2.3The welding parameters are set by means of knobAI.
Synergic MiG Welding LED AQ on.
Select the PROG number based on the wire diameter
to be used, the type and quality of the material, and the
type of gas, using the instructions located inside the wire
feeder compartment.
Set the functions in the submenu according to the
instructions under paragraph «Service functions».
Adjust the wire speed and the welding voltage using the
knob AI.
Conventional MiG Welding LED AR on.
Select the PROG number based on the wire diameter
to be used, the type and quality of the material, and the
type of gas, using the instructions located inside the wire
feeder compartment.
Set the functions in the submenu according to the
instructions under paragraph «Service functions».
Adjust the wire speed and the welding voltage using the
knob AI. and AN respectively.
17
8 ACCESSORIES
8.1 MIG WELDING TORCH ART. 1242
Air-cooled CEBORA MIG welding torch 280 A 3,5.
8.2 PUSH-PULL UP/DOWN WELDING TORCH, air
cooled, ART. 2003 and 2009.
8.3 Cooling unit Art. 1683
8.4 Water-cooled MIG torch Art. 1241
9 MAINTENANCE
Any maintenance operation must be carried out by
qualied personnel in compliance with standard CEI
26-29 (IEC 60974-4).
9.1 GENERATOR MAINTENANCE
In the case of maintenance inside the machine, make sure
that the switch L is in position “O” and that the power
cord is disconnected from the mains.
Even though the machine is equipped with an automatic
condensation drainage device that is tripped each time
the air supply is closed, it is good practice to periodically
make sure that there is no condensation accumulated in
the water trap J(g.1).
It is also necessary to periodically clean the interior of
the machine from the accumulated metal dust, using
compressed air.
9.2 PRECAUTIONS AFTER REPAIRS.
After making repairs, take care to organize the wiring so
that there is secure insulation between the primary and
secondary sides of the machine. Do not allow the wires
to come into contact with moving parts or those that heat
up during operation. Reassemble all clamps as they were
on the original machine, to prevent a connection from
occurring between the primary and secondary circuits
should a wire accidentally break or be disconnected.
Also mount the screws with geared washers as on the
original machine.
91
QUESTA PARTE È DESTINATA ESCLUSIVAMENTE AL PERSONALE QUALIFICATO.
THIS PART IS INTENDED SOLELY FOR QUALIFIED PERSONNEL.
DIESER TEIL IST AUSSCHLIEßLICH FÜR DAS FACHPERSONAL BESTIMMT.
CETTE PARTIE EST DESTINEE EXCLUSIVEMENT AU PERSONNEL QUALIFIE.
ESTA PARTE ESTÁ DESTINADA EXCLUSIVAMENTE AL PERSONAL CUALIFICADO.
ESTA PARTE È DEDICADA EXCLUSIVAMENTE AO PESSOAL QUALIFICADO.
TÄMÄ OSA ON TARKOITETTU AINOASTAAN AMMATTITAITOISELLE HENKILÖKUNNALLE.
DETTE AFSNIT HENVENDER SIG UDELUKKENDE TIL KVALIFICERET PERSONALE.
DIT DEEL IS UITSLUITEND BESTEMD VOOR BEVOEGD PERSONEEL.
DENNA DEL ÄR ENDAST AVSEDD FÖR KVALIFICERAD PERSONAL.
AUTOV TO TMHVMA PROORIVZETAI APOKLEISTIKAV GIA TO EIDIKEUMEVNO PROSWPIKO.V
92
POS DESCRIZIONE DESCRIPTION
01 CHIUSURA CLOSING
02 ROSET TA WASHER
03 LATERALE FISSO SIN. ANT.
FRONT FIXED LEFT SIDE
PANEL
04 LATERALE MOBILE HINGED SIDE PANEL
05 CERNIERA HINGE
06 LATERALE FISSO SIN. POST.
BACK FIXED LEFT SIDE
PANEL
07 PULSANTE DI SICUREZZA SECURITY SWITCH
08 CHIUSURA CLOSING
09 PORTA BOBINA COIL SUPPORT
10 SUPPORTO BOBINA SX. LEFT COIL SUPPORT
11 SUPPORTO BOBINA DS. RIGHT COIL SUPPORT
12 INTERRUTTORE SWITCH
13 PROTEZIONE PROTECTION
14 PANNELLO POSTERIORE REAR PANEL
15 PRESSACAVO STRAIN RELIEF
16 CAVO RETE POWER CORD
17
CONNESSIONE
PRESSOSTATO
PRESSURE SWITCH
CONNECTION
18 PRESSOSTATO PRESSURE SWITCH
19 PORTAFUSIBILE FUSE HOLDER
20 GOLFARA EYEBOLT
21 CORNICE FRAME
22 PANNELLO ALETTATO FINNED PANEL
24 ELETTROVALVOLA SOLENOID VALVE
25 KIT MOTORI CON VENTOLE MOTOR WITH FAN KIT
26 SUPPORTO MOTORE MOTOR BRACKET
27 COPERCHIO COVER
28 LATERALE FISSO DES. POS. BACK FIXED RIGHT PANEL
29 LATERALE DES. INFERIORE RIGHT LOWER SIDE PANEL
30 LATERALE FISSO DES. ANT. FRONT FIXED RIGHT PANEL
31 FONDO BOTTOM
32 RINFORZO REINFORCEMENT
33 SUPPORTO TORCIA TORCH SUPPORT
34 SUPPORTO MANICO HANDLE SUPPORT
POS DESCRIZIONE DESCRIPTION
35 MANICO HANDLE
36 LATERALE SIN. INFERIORE LEFT LOWER SIDE PANEL
37 GOLFARA EYEBOLT
38 TAPPO USB USB CAP
39 COMMUTATORE SWITCH
40 PRESA SOCKET
41 PANNELLO ANTERIORE FRONT PANEL
42 CORPO ADAT TATORE ADAPTOR BODY
43 TAPPO CAP
44 MANOPOLA KNOB
45 PROTEZIONE PROTECTION
46 GHIERA ADAT TATORE RING NUT
47 PROTEZIONE PROTECTION
48 CIRCUITO PANNELLO PANEL CIRCUIT
49 CIRCUITO DI CONTROLLO CONTROL CIRCUIT
50 PIANO INTERMEDIO INSIDE BAFFLE
51 CIRCUITO DI CONTROLLO CONTROL CIRCUIT
52 SUPPORTO SUPERIORE DS. RIGHT TOP SUPPORT
53 PIANO INTERMEDIO INSIDE BAFFLE
54 ISOLAMENTO INSULATION
55 CIRCUITO DI POTENZA POWER CIRCUIT
56 CONNESSIONE CONNECTION
57 TRASDUTTORE TRANSDUCER
58 IMPEDENZA SECONDARIO SECONDARY IMPEDANCE
59
TRASFORMATORE DI
POTENZA
POWER TRANSFORMER
60 PROTEZIONE PROTECTION
61 RINFORZO TUNNEL TUNNEL REINFORCEMENT
62 PROTEZIONE SCHEDA CIRCUIT PROTECTION
63 SUPPORTO TUNNEL TUNNEL SUPPORT
64 TUNNEL TUNNEL
65 MASSA + CAVO CABLE
66 CIRCUITO SERIALE SERIAL CIRCUIT
390 TRAINAFILO WIRE FEED UNIT
401 TRAINAFILO WIRE FEED UNIT
La richiesta di pezzi di ricambio deve indicare sempre:
numero di articolo, matricola e data di acquisto della
macchina, posizione e quantità del ricambio.
When ordering spare parts please always state the ma-
chine item and serial number and its purchase data, the
spare part position and the quantity.
93
94
POS DESCRIZIONE DESCRIPTION
401 TRAINAFILO WIRE FEED UNIT
411 MOTORIDUTTORE WIRE FEED MOTOR
412 ENCODER ENCODER
413
MOTORIDUTTORE
COMPLETO
COMPLETE WIRE FEEDER
MOTOR
421 BLOCCAGGIO GRADUATO ADJUSTMENT KNOB
422 GUIDAFILO WIRE DRIVE PIPE ASSY
423 CORPO TRAINAFILO WIRE FEED BODY
424 ISOLANTE COMPLETO INSULATION ASSY
POS DESCRIZIONE DESCRIPTION
425
PROTEZIONE
MOTORIDUTTORE
WIRE FEED PROTECTION
426
CORPO TRAINAFILO
COMPLETO
COMPLETE WIRE FEED BODY
428 RULLO TRAINAFILO WIRE FEED ROLLER
429 POMELLO KNOB
442 GRUPPO TRAINAFILO WIRE FEED UNIT
460 SUPPORTO PREMIRULLO ROLLER PRESSER SUPPORT
462 INGRANAGGIO GEAR
463 KIT INGRANAGGI GEARS KIT
La richiesta di pezzi di ricambio deve indicare sempre:
numero di articolo, matricola e data di acquisto della
macchina, posizione e quantità del ricambio.
When ordering spare parts please always state the ma-
chine item and serial number and its purchase data, the
spare part position and the quantity.
95
POS DESCRIZIONE DESCRIPTION
390 TRAINAFILO DESTRO RIGHT WIRE FEED UNIT
412 ENCODER ENCODER
420 SUPPORTO PREMIRULLO ROLLER PRESSER SUPPORT
421 BLOCCAGGIO GRADUATO ADJUSTMENT KNOB
422 GUIDAFILO WIRE DRIVE PIPE ASSY
423 CORPO TRAINAFILO WIRE FEED BODY
424 ISOLANTE COMPLETO INSULATION ASSY
425
PROTEZIONE
MOTORIDUTTORE
WIRE FEED PROTECTION
POS DESCRIZIONE DESCRIPTION
426
CORPO TRAINAFILO
COMPLETO
COMPLETE WIRE
FEED BODY
428 RULLO TRAINAFILO WIRE FEED ROLLER
429 POMELLO KNOB
447 GRUPPO TRAINAFILO WIRE FEED UNIT
462 INGRANAGGIO GEAR
464 MOTORIDUTTORE DESTRO RIGHT WIRE FEED MOTOR
465
MOTORIDUTTORE DESTRO
COMPLETO
COMPLETE RIGHT WIRE
FEED MOTOR
489 KIT INGRANAGGI GEARS KIT
La richiesta di pezzi di ricambio deve indicare sempre:
numero di articolo, matricola e data di acquisto della
macchina, posizione e quantità del ricambio.
When ordering spare parts please always state the ma-
chine item and serial number and its purchase data, the
spare part position and the quantity.
96
POS DESCRIZIONE DESCRIPTION
77 SUPPORTO CAVI CABLES SUPPORT
78 APPOGGIO BOMBOLA GAS CYLINDER SUPPORT
79 CINGHIA BELT
80 SUPPORTO BOMBOLA GAS CYLINDER SUPPORT
81 FONDO BOTTOM
82 SUPPORTO ASSALE AXLE SUPPORT
83 ASSALE AXLE
84 RUOTA FISSA FIXED WHEEL
CARRELLO PER
TRASPORTO GENERATORE
TROLLEY FOR TRANSPORTATION
OF THE POWER SOURCE
POS DESCRIZIONE DESCRIPTION
85 TAPPO CAP
86 SUPPORTO RUOTE WHEELS SUPPORT
87 RUOTA PIROET TANTE SWIVELING CASTOR
88 PANNELLO INTERNO INSIDE PANEL
89 PANNELLO CHIUSURA LID
90 SUPPORTO GENERATORE POWER SOURCE SUPPORT
91 APPOGGIO REST
92 ATTACCO SUPP. BOMBOLA SUPPORT CONNECTOR
97
98
CODIFICA COLORI
CABLAGGIO ELETTRICO
WIRING DIAGRAM
COLOUR CODE
A NERO BLACK
B ROSSO RED
C GRIGIO GREY
D BIANCO WHITE
E VERDE GREEN
F VIOLA PURPLE
G GIALLO YELLOW
H BLU BLUE
K MARRONE BROWN
J ARANCIO ORANGE
I ROSA PINK
CODIFICA COLORI
CABLAGGIO ELETTRICO
WIRING DIAGRAM
COLOUR CODE
L NROSA-NERO PINK-BLACK
M GRIGIO-VIOLA GREY-PURPLE
N BIANCO-VIOLA WHITE-PURPLE
O BIANCO-NERO WHITE-BLACK
P GRIGIO-BLU GREY-BLUE
Q BIANCO-ROSSO WHITE-RED
R GRIGIO-ROSSO GREY-RED
S BIANCO-BLU WHITE-BLUE
T NERO-BLU BLACK-BLUE
U GIALLO-VERDE YELLOW-GREEN
V AZZURRO BLUE
99
100
CEBORA S.p.A - Via Andrea Costa, 24 - 40057 Cadriano di Granarolo - BOLOGNA - Italy
Tel. +39.051.765.000 - Fax. +39.051.765.222
www.cebora.it - e-mail: [email protected]
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Cebora JAGUAR SOUND MIG 2060 Manuale utente

Categoria
Sistema di saldatura
Tipo
Manuale utente

in altre lingue