Smontaggio/ Dismantling
1
Fig. 4
Sostituzione
Replacing
In caso di sostituizione del terminale utente, per
evitare malfunzionamenti:
1. spegnere (togliere l’alimentazione) l’unità;
2. sostituire il terminale utente;
3. riavviare l’unità.
In case of replacing the user terminal, to
avoid malfunctions:
1. switch off (unplug) the unit;
2. replace the user terminal;
3. restart the unit.
Comunicazione NFC/BLE
NFC/BLE communication
La comunicazione NFC (Near Field
Communication), semplice e rapida, e la
comunicazione BLE (Bluetooth Low Energy)
possono essere usate in fase di messa in servizio
del controllo. Per ulteriori informazioni consultare
il manuale del sistema MPXone cod. +0300086IT.
NFC (Near Field Communication) is
simple and fast and can be used when
commissioning the controller. For further
information, see the MPXone system manual
+0300086EN.
300086_028_R01
Fig. 5
Connessioni elettriche / Electrical connections
Terminale utente
User terminal
J8
J4 BMS
J3 J2
J5 FBus
S1 S3 5V
S2Y2
Y1ID1
ID2
ID3ID5
ID4S4
S6 +V
VL S5
to user terminal
ACS00CB0000** cable
Display remoto Remote display
GND
Rx+/Tx+
Power supply
Rx-/Tx-
J1J7
NO4CG0 G
J6
NO2 NO3
C
NO1
J2
J3
J4 BMSJ5 FBus
S1 S3 5V
S2Y2
Y1ID1
ID2
ID3ID5
ID4S4
S6 +V
VL S5
Fig. 6
E13 Sonda seriale S13 non aggiornata
E14 Sonda seriale S14 non aggiornata
LO Bassa temperatura
HI Alta temperatura
LO2 Bassa temperatura
HI2 Alta temperatura
IA Allarme immediato da contatto esterno
dA Allarme ritardato da contatto esterno
dor Porta aperta per troppo tempo
Etc Real time clock non aggiornato
LSH Basso surriscaldamento
LSA Bassa temperatura di aspirazione
MOP Max pressione di evaporazione
LOP Bassa temp. di evaporazione
bLo Valvola bloccata
Edc Errore di comunicazione con driver stepper
EFS Motore stepper rotto/non collegato
HA HACCP di tipo HA
HF HACCP di tipo HF
MA Errore di comunicazione con il Master (solo su Slave)
u1...u9 Errore di comunicazione con lo Slave (solo su Master)
n1...n9 Allarme sull’unità 1...9 presente in rete
GPE Errore nei parametri per il gas custom
Caratteristiche tecniche
Alimentazione 13 Vdc ± 10% ottenuta da controllo
ACU; assorbimento 250 mA max.
Alimentazione raccomandata per il
controllo collegato: SELV o PELV
Connettore (integrato) JST 4 poli ZH p.n. S4B-ZR-SM4A-TF
Cavo di collegamento al controllo Lunghezza max: 10m. In caso
di lunghezze superiori ai 2m
e dispositivo non incorporato,
utilizzare cavo schermato.
Sezione: AWG: 26
Connettori:
• lato terminale: JST ZH 4 vie;
housing ZHR-4; terminale SZH-
002T-P0.5
• lato controllo:
– terminale utente: JST XH 4 vie,
housing XHP-4, terminale SXH-
002T-P0.6
– display remoto: fi li a cablare
Buzzer Disponibile in tutti i modelli
Contenitore Materia plastica in policarbonato
Dimensioni: vedere fi gure
Montaggio a pannello
Display 3 digit, punto decimale e icone
polifunzionali
Temperatura di funzionamento -20T60°C
Umidità di funzionamento <90% U.R. non condensante
Temperatura immagazzinamento -35T70°C
Umidità di immagazzinamento <90% U.R. non condensante
Comunicazione NFC Max distanza 10 mm, variabile
secondo il dispositivo mobile
utilizzato
Bluetooth Low Energy Max distanza 10m, variabile secondo
il dispositivo mobile utilizzato
Grado di protezione IP65 sul frontale,
IP20 sul retro
Grado Inquinamento ambientale 3
Temp. per la prova con la sfera 125°C
Tensione di impulso nominale 0.8 kV
Tipo di azione e disconnessione 1.Y
Costruzione del dispositivo di
comando
Dispositivo da incorporare
Classifi cazione secondo la
protezione contro le scosse
elettriche
Incorporabile in apparecchi di classe
I o II
Interfaccia seriale Modbus su RS485
Classe e struttura del software Classe A
Pulizia frontale Utilizzare esclusivamente un panno
morbido e non abrasivo e detergenti
neutri o acqua
Conformità
Sicurezza UL UL60730-1
Sch. CB IEC60730-1
EMC CE EN61000-6-1, EN61000-6-2, EN61000-6-3,
EN61000-6-4, EN55014-1, EN55014-2, EN61000-3-2
Radio
Red EN301489-1/EN301489-17, EN300328
FCC Contains FCC ID: WAP2001
IC Contains IC: 7922A-2001
ANATEL
ID: 03780-21-05684
Este equipamento não tem direito à proteção
contra interferência prejudicial e não pode
causar interferência em sistemas devidamente
autorizados.
Applicazione con gas refrigerante in ammabile (*)
L’utilizzo di questo prodotto con i refrigeranti infi ammabili di tipo A3, A2 o
A2L, è stato valutato e giudicato conforme ai seguenti requisiti:
• Allegato CC della IEC 60335-2-24:2010 a cui fa riferimento la clausola
22.109 e l’allegato BB della IEC 60335-2-89:2019 a cui fa riferimento la
clausola 22.113; i componenti che producono archi o scintille durante il
funzionamento normale sono stati testati e trovati conformi con i requisiti
delle UL/IEC 60079-15;
• IEC 60335-2-24:2010 (clausola 22.110)
• IEC 60335-2-40:2018 (clausola 22.116, 22.117)
• IEC 60335-2-89:2019 (clausola 22.114)
Le temperature superfi ciali di tutti i componenti e parti sono state misurate e
verifi cate durante le prove previste dalla norma IEC 60335 cl. 11 e 19, e trovate
non superiori a 268 °C. L’accettabilità di questi controlli in applicazioni fi nali in
cui è previsto l’utilizzo di refrigerante infi ammabile deve essere riesaminata e
giudicata nell’applicazione fi nale.
(*) Applicabile ai prodotti con revisione superiore a 1.5xx.
E13 Serial probe S13 not updated
E14 Serial probe S14 not updated
LO Low temperature
HI High temperature
LO2 Low temperature
HI2 High temperature
IA Immediate alarm from external contact
dA Delayed alarm from external contact
dor Door open for too long
Etc Real time clock not updated
LSH Low superheat
LSA Low suction temperature
MOP Max evaporation pressure
LOP Low evaporation pressure
bLo Valve blocked
Edc Communication error with stepper driver
EFS Stepper motor broken/not connected
HA HACCP type HA
HF HACCP type HF
MA Communication error with the Master (only on Slave)
u1...u9 Communication error with the Slave (only on Master)
n1...n9 Alarm on unit 1 ... 9 in the network
GPE Error in the custom gas parameters
Technical speci cations
Power supply 13 Vdc ± 10% supplied by ACU
controller; max current 250 mA.
Power supply recommended for the
connected controller: SELV or PELV
Connector (built-in) JST 4 pin ZH P/N S4B-ZR-SM4A-TF
Controller connection
cable
Max length: 10m. If of lengths longer
than 2m and device not uilt-in, use
shielded cable.
Size: AWG: 26
Connectors:
• terminal side: JST ZH 4 pin; housing
ZHR-4; terminal SZH-002T-P0.5
• control side:
– user terminal: JST XH 4 way,
housing XHP-4, terminal SXH-
002T-P0.6
– remote display: wires to wire
Buzzer Available on all models
Temperature sensor Built-in
Casing Polycarbonate material
Dimensions: see fi gures
Assembly Panel mounting
Display 3 digits, decimal point and
multifunction icons
Operating temperature -20T60°C
Operating humidity <90% RH non-condensing
Storage temperature -35T70°C
Storage humidity <90% RH non-condensing
NFC Max distance 10 mm, variable
according to the mobile device used
Bluetooth Low Energy Max length 10m, depend on the used
mobile device
Index protection IP65 at front,
IP20 at rear
Environmental pollution 3
Ball pressure test 125°C
Rated impulse voltage 0.8 kV
Type of action and disconnection 1.Y
Construction of the control device Device to be incorporated
Classifi cation according to
protection against electric shock
To be incorporated in class 1 or 2
appliances
Serial interface Modbus over RS485
Software class and structure Class A
Cleaning the front side Only use a soft, non-abrasive cloth and
neutral detergents or water
Conformity
Safety UL UL60730-1
Sch. CB IEC60730-1
EMC CE
EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-
6-4
EN55014-1, EN55014-2, EN61000-3-2
Radio
Red EN301489-1/EN301489-17, EN300328
FCC Contains FCC ID: WAP2001
IC Contains IC: 7922A-2001
ANATEL
ID: 03780-21-05684
Este equipamento não tem direito à proteção
contra interferência prejudicial e não pode causar
interferência em sistemas devidamente autorizados.
Applications with ammable gas refrigerant (*)
About the use of this product with A3, A2 or A2L fl ammable refrigerants, it
has been evaluated and judged compliant with the following requirements:
• Annex CC of IEC 60335-2-24:2010 referenced by clause 22.109 and Annex
BB of IEC 60335-2-89:2019 referenced by clause 22.113; components that
produce arcs or sparks during normal operation have been tested and
found to comply with the requirements in UL/IEC 60079-15;
• IEC 60335-2-24:2010 (clauses 22.110)
• IEC 60335-2-40:2018 (clauses 22.116, 22.117)
• IEC 60335-2-89:2019 (clauses 22.114)
Surface temperatures of all components and parts have been measured and
verifi ed during the tests required by IEC 60335 cl. 11 and 19, and found not
exceeding 268 °C.
Acceptability of these controllers in end use application where fl ammable
refrigerant is used shall be reviewed and judged in the end use application.
(*) Applicable to the products with revision above 1.5xx.
Smaltimento del prodotto /
Disposal of the product
L’apparecchiatura (o il prodotto) deve essere oggetto di raccolta separata in conformità alle vigenti normative
locali in materia di smaltimento. /
The appliance (or the product) must be disposed of separately in compliance
with the local standards in force on waste disposal.
AVVERTENZE IMPORTANTI
Il prodotto CAREL è un prodotto avanzato, il cui funzionamento è speci cato nella documentazione tecnica fornita col prodotto o scaricabile,
anche anteriormente all’acquisto, dal sito internet www.carel.com. Il cliente (costruttore, progettista o installatore dell’equipaggiamento
nale) si assume ogni responsabilità e rischio in relazione alla fase di con gurazione del prodotto per il raggiungimento dei risultati previsti
in relazione all’installazione e/o equipaggiamento nale speci co. La mancanza di tale fase di studio, la quale è richiesta/indicata nel
manuale d’uso, può generare malfunzionamenti nei prodotti nali di cui CAREL non potrà essere ritenuta responsabile. Il cliente nale deve
usare il prodotto solo nelle modalità descritte nella documentazione relativa al prodotto stesso. La responsabilità di CAREL in relazione al
proprio prodotto è regolata dalle condizioni generali di contratto CAREL editate nel sito www.carel.com e/o da speci ci accordi con i clienti.
IMPORTANT WARNINGS
The CAREL product is a state-of-the-art product, whose operation is speci ed in the technical documentation supplied with the product
or can be downloaded, even prior to purchase, from the website www.carel.com. - The client (builder, developer or installer of the nal
equipment) assumes every responsibility and risk relating to the phase of con guration the product in order to reach the expected results
in relation to the speci c nal installation and/or equipment. The lack of such phase of study, which is requested/indicated in the user
manual, can cause the nal product to malfunction of which CAREL can not be held responsible. The nal client must use the product only
in the manner described in the documentation related to the product itself. The liability of CAREL in relation to its own product is regulated
by CAREL’s general contract conditions edited on the website www.carel.com and/or by speci c agreements with clients.
Il manuale d’uso (cod. +0300086IT) completo del
prodotto è scaricabile sul sito www.carel.com alla
sezione “Services/Documentation” o tramite QR
Code.
The complete user manual ( +0300086EN) for the
product can be downloaded at www.carel.com
under the “Services / Documentation” section
or via QR Code.