6
EN
Model 233344 233351 233382 233399
Refrigerant/
Amount [kg]
R600a/0,10 R290/0,09 R600a/0,10 R290/0,09
GWP - - - -
Climate class 5** 4* 5** 4*
CO2 equivalent [kg] - - - -
EEI B C B C
Temp. range [°C] -2/+8 -12/-22 -2/+8 -12/-22
Weight [kg] 71 71 81 81
Appliances are designed to work efficiently on the
ambient of * +10°C/+30°C, ** +10°C/+40°C.
Climate class indicates the maximum ambient
temperature at the place of appliance installation.
Compliance with the determined maximum ambi-
ent temperature ensures that internal temperature
inside the appliance is maintained and products
are safely stored. Remember that too high ambi-
ent temperature of the environment in which the
cooling or freezing cabinet is placed may influence
power consumption and have impact on storage
safety of the products placed inside.
The manufacturer and dealer is not liable for any
inaccuracies due to printing errors or transcription,
in this manual. In line with our policy of continu-
ous improvement products, we reserve the right to
make modification of the product, packaging and
specifications contained in the Documentation with-
out prior notice.
6. BEFORE THE FIRST USE
6.1. TRANSPORT
• Special package box is required for the delivery of
the equipment. Keep the equipment level during
transportation and handling.
• Please carefully check the package box after re-
ceiving the product to ensure that the equipment
is not damaged during transportation.
• Check for the completeness of the equipment. In
case of incomplete delivery and damages. Please
contact supplier (See == > Warranty).
• When removing the package box, carefully move
away the wood plate in case of scratch the equip-
ment.
• In case that the equipment tilts during the trans-
portation and handling, the lubricant in the com-
pressor may flow into the cooling loop. Therefore,
in order to ensure the lubricant flows back to the
compressor, it is necessary to keep the equipment
level for 24 hours before plug in the equipment
and starts to work.
• Do not throw away the package randomly. Please
dispose as per relevant local rules and regula-
tions.
• Clean all components as described (See == >
Cleaning and Maintenance).
• Place all the shelves inside the appliance.
NOTE: Due to manufacturing residues, the appli-
ance may emit a slight odor in the first few cycles.
This is normal and does not indicate any defect or
hazard. Make sure the appliance is well ventilated.
• Turn on the lighting switch, check the light is nor-
mal.
• The digital temperature controller is delivered
with default parameters. Do not alter the param-
eters casually except for special need.
• When running for the first time, it should run
without load for 2 hours to ensure the refriger-
ation system is working normally. Only when the
temperature within the appliance is reduced with-
in the indicated scope can the food be put into the
appliance.
• Don’t put too much food in the appliance to pre-
vent instantaneous high load. The food shall not