Pella 80KM0103 Manuale utente

Tipo
Manuale utente
INSTALLATION INSTRUCTIONS
HINGED PATIO DOOR - SOUTHWESTERN WALL WITH HARD COAT STUCCO
Installation Instructions for Typical Wood Frame Construction.
These instructions were developed and tested for use with typical wood frame wall construction in a wall system designed to manage water.
These instructions are not to be used with any other construction method. Installation instructions for use with other construction methods,
multiple units or bow and bay windows, may be obtained from Pella
®
Corporation or a local Pella retailer. Building designs, construction methods,
building materials, and site conditions unique to your project may require an installation method different from these instructions and additional
care. Determining the appropriate installation method is the responsibility of you, your architect, or construction professional.
YOU WILL NEED TO SUPPLY:
s#EDAROR)MPERVIOUSSHIMSSPACERSTO
sGALVANIZEDROOlNGNAILSLB
s#LOSEDCELLFOAMBACKERRODSEALANTBACKERTOFT
s0ELLA
®
3MART&LASHFOILBACKEDBUTYLWINDOWANDDOOR
flashing tape or equivalent
s(IGHQUALITYEXTERIORGRADEPOLYURETHANEORSILICONESEALANT
TOTUBESPERDOOR
s'REAT3TUFF
Window and Door Insulating Foam Sealant
by the Dow Chemical Company or equivalent low pressure
polyurethane window and door foam - DO NOT use high
PRESSUREORLATEXFOAMS
s0ELLAALUMINUMSILLSUPPORTORXWOODBLOCKING
s)NTERIORTRIMANDORJAMBEXTENSIONSTOFT
sWIDE&ORTIlBERmASHINGPAPEROREQUIVALENT
TOOLS REQUIRED:
s4APEMEASURE
sg,EVEL
s3QUARE
s(AMMER
s3TAPLER
s3EALANTGUN
s3CISSORSORUTILITYKNIFE
s$RILL
s3CREWDRIVERS
0HILLIPSWITHSHAFTANDSMALLmATBLADE
4&"-"/5
4&"-"/5

'
M
B
T
I
J
O
H
1
B
Q
F
S

'
M
B
T
I
J
O
H
1
B
Q
F
S
'MBTIJOH1BQFS
4JMM'MBTIJOH5BQF
4JMM'MBTIJOH5BQF
4JMM4VQQPSU
5PQ
'MBTIJOH
5BQF
'JO
$PSOFS
4JEF
'MBTIJOH
5BQF
*OUFSMPDLFS
4JEF
'MBTIJOH
5BQF
/BJMJOH'JO
XJEF'MBTIJOH1BQFS
Always read the Pella
®
,IMITED7ARRANTYBEFOREPURCHASINGORINSTALLING0ELLAPRODUCTS"YINSTALLINGTHISPRODUCTYOUAREACKNOWLEDGING
that this Limited Warranty is part of the terms of the sale. Failure to comply with all Pella installation and maintenance instructions may void your Pella product
warranty. See Limited Warranty for complete details at http://warranty.pella.com.
REMEMBER TO USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT.
Part Number: 80KM0103
©2008 Pella Corporation
1 ROUGH OPENING PREPARATION
A. Verify the opening is plumb and level.
Note: It is critical that the bottom is level.
B. Verify the door will fit the opening.-EASUREALLFOURSIDESOFTHEOPENINGTOMAKE
SUREITISLARGERTHANTHEDOORINWIDTHANDLARGERINHEIGHT-EASURETHE
width at the top, bottom, and center. Measure the height at the far left side, the far
right side, and in the center.
Note: 1-1/2" or more of solid wood blocking is required around the perimeter of
the opening. Fix any problems with the rough opening before proceeding.
C. Apply flashing paper at the bottom##UTONEPIECEOFmASHINGPAPERLONGER
than the width of the rough opening. Position the top edge of the flashing paper with
the top of the sill plate. Center the flashing paper with the opening width. Staple the
flashing paper to the sill plate.
Note: Sill flashing paper is not required for installation on concrete floors.
D. Apply flashing paper to the sides of the rough opening$#UTTWOPIECESOF
mASHINGPAPERLONGERTHANTHEHEIGHTOFTHEROUGHOPENING!PPLYONEPIECETO
each jamb. Position the edge of the flashing paper with the inside edge of the trimmer
JACKSTUDANDCENTERTHEmASHINGPAPERWITHTHEHEIGHTOFTHEROUGHOPENING3TAPLE
the flashing paper to the trimmer.
E. Apply bottom flashing tape #1.#UTAPIECEOFmASHINGTAPELONGERTHANTHEOPENING
WIDTH!PPLYATTHEBOTTOMOFTHEOPENINGASSHOWN%SOITOVERHANGSTOTHEEXTERIOR
Note: The tape is cut 12" longer than the width of the opening so that it will extend up
each side approximately 6".
F. Tab the bottom flashing tape and fold.#UTWIDETABSATEACHCORNERFROMEACHSIDE
OFCORNER&&OLDTAPETOTHEEXTERIORANDPRESSlRMLYTOADHEREITTOTHEmASHINGPAPER
'Apply bottom flashing tape #2.#UTAPIECEOFmASHINGTAPELONGERTHANTHEOPENING
WIDTH!PPLYATTHEBOTTOMOVERLAPPINGTAPEBYATLEAST$/./4ALLOWTHETAPETO
EXTENDPASTTHEINTERIORFACEOFTHEFRAMING'
In-swing Architect Series
®
and Designer Series
®
:)FTHEWALLDEPTHISGREATERTHANADDA
THIRDPIECEOFmASHINGTAPE4HEmASHINGTAPESHOULDCOMETOWITHINOFTHEINTERIORFACEOF
the framing.
Note: The flashing tape does not need to extend all the way to the interior of the framing.
(Attach the aluminum sill support or wood blockingTOTHEEXTERIOROFTHEBOXPLATE
to support the edge of the door sill. Place the sill support flush with the subfloor.
£
£
£
£




£
£

£
£
2 SETTING AND FASTENING THE DOOR
A. Remove plastic wrap and cardboard packaging from door. DO NOT remove plastic
SHIPPINGSPACERS4HESHIPPINGSPACERSWILLHELPKEEPTHEDOORSQUAREDURINGINSTALLATION
$/./4UNLOCKOROPENTHEDOORUNTILITISFULLYFASTENED
Note: If screens, grilles or hardware are removed from the door at this time, label
them and store them in a protected area.
B. Fold out installation fin to 90°."ECAREFULNOTTOREMOVEORTEARTHElNCORNERS
Note: If the fin is not at 90°, the door will not line up correctly on the interior.
C. Place three 3/8" beads of sealant.4HElRSTBEADSHOULDBEAPPROXIMATELYFROM
THEEXTERIOROFTHEROUGHOPENINGTHESECONDBEADSHOULDBEPLACEDSOITISUNDERTHE
WOODINTERIORTHRESHOLDOFTHEDOOR0LACEMENTWILLVARYDEPENDINGONWALLTHICKNESS
ANDDOORTYPE0LACEATHIRDBEADOFSEALANTINTHEGROOVEOFTHESILLSUPPORTOR
FROMTHEEXTERIOREDGEOFTHEWOODBLOCKING
TWO OR MORE PEOPLE WILL BE REQUIRED FOR THE FOLLOWING STEPS.
D. Insert the doorFROMTHEEXTERIOROFTHEBUILDING$/./4SLIDETHEBOTTOMOF
the door into the opening. Sliding will damage the sealant lines. Place the bottom
of the door at the bottom of the opening, then tilt the top into position. Center the
door between the sides of the opening to allow clearance for shimming, and insert
ONEROOlNGNAILINTHElRSTHOLEFROMTHECORNERONEACHENDOFTHETOPNAILINGlN
These are used to hold the door in place while shimming it plumb and square.
E. Plumb and square door.0LACESHIMSATEACHHINGEANDLOCKSTRIKELOCATIONBETWEENTHE
DOORANDTHESIDESOFTHEOPENING)NSERTSHIMSINOTHERLOCATIONSASNEEDEDSTARTINGUP
FROMTHEBOTTOMOFTHEDOORTOSQUAREITINTHEOPENING-AKESURETHATTHEREVEALAROUND
THEDOORSISEQUAL/NDOUBLEDOORSMAKESURETHATPANELSAREEVENACROSSTHEBOTTOM
Note: On center latch double doors the lock strike will not be shimmed since it is
located in the center of the unit. DO NOT over shim.
F. Check the interior reveal.-AKESURETHEMEASUREMENTFROMTHEINTERIORFACEOFTHEDOOR
to the interior face of the wall is equal at several points around the door.
Note: If the dimensions are not equal, check to make sure the fins are folded out to 90°
at all points.
Ó
Ó
&YUFSJPS
Ó
&YUFSJPS
Ó
*OUFSJPS
Ó
Ó
Ó
£
Óä
Îä {ä xä Èä Çä
ÓÎ
 -

Ó
'Fasten the door to openingBYDRIVINGGALVANIZEDROOlNGNAILSINTOEACH
PREPUNCHEDHOLEINTHENAILINGlN
Note: Make sure the fin corner is lying as flat as possible. When using
the optional fin at the sill, attach the aluminum sill support or wood
blocking under the sill of the door before proceeding to Step H.
( Carefully open the door(s) and remove all shipping spacers.
Note: Be sure to remove the spacers from the bottom edge of the door panel.
Double doors with center latch:
Designer Series Only: Use the construction handle to operate the active door
HANDLE/PERATETHEmUSHBOLTSPERTHEINSTRUCTIONSONTHELABELONTHESTRIKE
located on the astragal.
Architect Series Only: Use the construction handle to operate both the active
and passive door panels.
I. Out-swing doors: Place a dab of sealant in each of the pre-drilled holes in the bottom of the door frame, then insert a
XmATHEADCORROSIONRESISTANTWOODSCREWPROVIDEDINTOTHISHOLE
Note: Single doors will have two pre-drilled holes, double doors will have four.
)Out-swing double doors only:0LACEADABOFSEALANTINTOTHECENTERHOLEOFTHESTRIKEPLATELOCATEDATTHESILLOFTHEDOOR
)NSTALLAXmATHEADCORROSIONRESISTANTWOODSCREWPROVIDEDINTOTHISHOLE
Note: For masonry floors, use a #8 masonry screw instead of the wood screw.
J. On center latching (double) doors: Place shims at the top of the door frame above
THECENTERSTRIKEPLATE3ECURETHESHIMSBYINSERTINGAXmATHEADCORROSION
RESISTANTSCREWINTOTHEUPPERDOORFRAMETHROUGHTHECENTERHOLEOFTHESTRIKEPLATE
and the shims into the rough opening.
*On center hinged double doors: Insert and attach shims directly
above the astragal in the center of the unit.
Note: Step K does not apply to center hinged doors.
K. On each hinge, starting at the top, insert a 3" long screwPROVIDEDINTOTHE
OPENSCREWHOLE-AKESURETHATTHESCREWPASSESTHROUGHTHESHIMSANDINTOTHE
structural framing.
L. Check door operation./PENANDCLOSETHEDOORTOCHECKFORPROPEROPERATION
-AKESURETHEDOORWILLLATCHCORRECTLY
Note: If there are any problems with the operation, recheck and adjust the reveal.
M. Adjust the reveal if needed.
Architect Series and Designer Series only:4HEDOORPANELSHAVEADJUSTABLEHINGELEAFS5SINGAALLENWRENCH
TURNTHECENTERSCREWCLOCKWISETOINCREASETHESPACEBETWEENTHEHINGESIDEOFTHEFRAMEANDTHEDOORPANELORCOUNTER
CLOCKWISETOINCREASETHESPACEBETWEENTHEDOORPANELANDTHELOCKSIDEOFTHEFRAME$/./4TURNTHESCREWSMORE
THANTURNINEITHERDIRECTION)NSOMECASESITMAYBENECESSARYTOLOOSENANDTHENTIGHTENTHETOPANDBOTTOMHINGE
screws to obtain full hinge adjustment. If necessary, loosen the top and bottom screws, and immediately retighten them.
With the screws retightened, turn the adjustment hinge screw. If the hinge will not adjust any further then it is adjusted
as far as it will go. If more clearance is needed adjust the shims between the frame and the rough opening.
Note: DO NOT adjust the hinge with the top and bottom screws loose; this could force the hinge to adjust beyond
its design capability which can cause the hinge to bind, damage the hinge and/or pull out the screws. A 3/4 turn of
the center screw provides approximately 1/16" adjustment.
Note: For more issues with the adjustable strike latching, go to the troubleshooting section at the end of this instruction.
ProLine Series only: Plastic shims located behind the hinges may be removed to adjust the reveal between the door panel
and door frame. Additional hinge shims may be added if required.
N. On doors with a lock strike in the side,DRILLADIAMETERXDEEPPILOTHOLETHROUGHTHELOCKSTRIKEANDINTOTHE
ROUGHOPENING)NSERTAXCORROSIONRESISTANTSCREWPROVIDEDINTOTHEPILOTHOLEMAKINGSURETHATITPASSESTHROUGH
the shim and into the stud.
Note: This step does not apply to center latching double doors.
O. Install a #8 x 3" flat head corrosion resistant screwINTOTHEHOLELOCATEDAPPROXIMATELYFROMTHETOPOFTHE
door frame, on the latch side of the frame.
&YUFSJPS
Ó
Ó
*OUFSJPS
Ó
Ó
Ó
Ó
3 INTEGRATING THE DOOR TO THE BUILDING FELT
Note: The flashing tape must be applied approximately 1/2" onto the frame cladding at the jambs and
head. Pre-folding the tape at 1/2" before removing the paper backing will make it easier to apply the
tape correctly. If the siding is less than 1/2" thick, adjust the dimension of the fold so the exterior sealant
line will cover the exterior edge of the tape.
A. Apply side flashing tape.#UTPIECESOFmASHING
TAPELONGERTHANTHEFRAMEHEIGHTOFTHEDOOR
!PPLYONEPIECEUPONTOTHEFRAMECLADDING
OVERTHENAILINGlNANDONTOTHEmASHINGPAPERTO
EACHSIDE4HETAPESHOULDEXTENDABOVETHETOP
OFTHEDOORANDBELOWTHEBOTTOMOFTHEDOOR
0RESSTHETAPEDOWNlRMLYWHILEFOLDINGDOWNTHE
EXCESSTAPEATTHETOPANDBOTTOMOFTHEDOOR
B. Apply top flashing tape. Cut a piece of flashing tape long enough to go across
THETOPOFTHEDOORANDEXTENDATLEASTPASTTHESIDEmASHINGTAPEONBOTHSIDES
!PPLYTHETAPEUPONTOTHEFRAMECLADDINGOVERTHETOPNAILINGlNASSHOWN
&OLDTHEOVERLAPPINGTAPEDOWNANDPRESSALLTAPEDOWNlRMLY
Note: The top flashing tape must overlap the side flashing tape to prevent
water from getting behind it.
C. Apply the top flashing paper.#UTONEPIECEOFmASHINGPAPERATLEASTLONGERTHANTHE
width of the rough opening. Position the bottom edge of the flashing paper flush with the
frame of the door and center the flashing paper with the door. Staple the flashing paper to
the header.
Note: When applying the first layer of building felt, ensure the sill flashing paper
overlaps the building felt. This will tie the door system into the building water
management system.
&YUFSJPS
Î
&YUFSJPS
Î

Î
4 INTERIOR SEAL
Caution: Ensure use of low pressure polyurethane window and door installation foams and strictly follow the foam manufacturer’s
recommendations for application. Use of high pressure foams or improper application of the foam may cause the door to bow and
hinder operation. DO NOT use fiberglass insulation.
A. Apply insulating foam. &ROMTHEINTERIORINSERTTHENOZZLEOFTHEAPPLICATORAPPROXIMATELY
DEEPINTOTHESPACEBETWEENTHEDOORANDTHEROUGHOPENINGANDAPPLYADEEPBEAD
OFFOAM4HISWILLALLOWROOMFOREXPANSIONOFTHEFOAMANDWILLMINIMIZESQUEEZEOUT)F
USINGFOAMOTHERTHAN'REAT3TUFF7INDOWAND$OOR)NSULATING&OAM3EALANTBYTHE
$OW#HEMICAL#OMPANYALLOWTHEFOAMTOCURECOMPLETELYUSUALLYTOHOURSBEFORE
PROCEEDINGTOTHENEXTSTEP
Note: DO NOT completely fill the space from the back of the fin to the interior face of
the opening.
*OUFSJPS
{
B. Check the door operation by opening and closing the door.
Note: If the door does not operate correctly, check to make sure it is still plumb, level, square and
that the sides are not bowed. If adjustments are required, remove the foam with a serrated knife.
Adjust the shims, and reapply the insulating foam sealant.
5 SEALING THE DOOR TO THE EXTERIOR WALL CLADDING
Note: When applying the casing bead for stucco, leave 1/2" space between the
head of the door and the casing bead, and 3/8" space between the door jambs
and the casing bead for backer rod and sealant. Refer to the illustration
(Southwestern Wall With Stucco).
Note: The sealant details shown are standard recommendations from the
sealant industry. Contact your sealant supplier for recommendations and
instructions for this and any other application.
A. Install the hardware.2EFERTOTHEINSTRUCTIONSINCLUDEDINTHEHARDWAREBOX
B. Insert backer rodINTOTHESPACEAROUNDTHEDOORLEAVINGATLEASTA
CLEARANCEBETWEENTHEBACKERRODANDTHEEXTERIORFACEOFTHECASINGBEAD
Note: Backer rod adds shape and depth for the sealant line.
C. Apply a bead of high quality exterior grade sealant
to the entire perimeter of the door. At each end of the
bottom of the door, insert sealant into the spaces between
the bottom of the door and the sill support and connect
it to the perimeter sealant.
D. Shape, tool and clean excess sealant. 7HENlNISHED
the sealant should be the shape of an hourglass.
Note: This method creates a more flexible sealant
line capable of expanding and contracting.
E. Remove plastic guards at the base of the door
once construction is complete.
4065)8&45&3/
8"--
8*5)
456$$0
$MFBSBODF
#BDLFS3PEBOE
4FBMBOUUZQJDBM
*OTVMBUJOH
'PBN
"DDFTTPSZ
(SPPWF

x
x
6 INTERIOR FINISHING
)FTHEPRODUCTSCANNOTBElNISHEDIMMEDIATELYCOVERWITHCLEARPLASTICTOPROTECTFROMDIRTDAMAGEANDMOISTURE2EMOVEANYCONSTRUCTION
RESIDUEBEFORElNISHING3ANDALLWOODSURFACESLIGHTLYWITHGRITORlNERSANDPAPER$/./4USESTEELWOOL"%#!2%&5,./44/
3#2!4#(4(%',!332EMOVESANDINGDUST
0ELLAPRODUCTSMUSTBElNISHEDPERTHEBELOWINSTRUCTIONSFAILURETOFOLLOWTHESEINSTRUCTIONSVOIDSTHE,IMITED7ARRANTY
s/NCASEMENTANDAWNINGSITISOPTIONALTOPAINTSTAINORlNISHTHEVERTICALANDHORIZONTALSASHEDGES
s/NSINGLEHUNGANDDOUBLEHUNGDONOTPAINTSTAINORlNISHTHEVERTICALSASHEDGESANYlNISHONTHEVERTICALSASHEDGESMAYCAUSETHESASH
TOSTICKITISOPTIONALTOPAINTSTAINORlNISHTHEHORIZONTALSASHEDGES
s/NPATIODOORSITISOPTIONALTOPAINTSTAINORlNISHTHEVERTICALANDHORIZONTALPANELEDGES
Note: To maintain proper product performance do not paint, finish or remove the weather-stripping, mohair dust pads, gaskets or vinyl
parts. Air and water leakage will result if these parts are removed. After finishing, allow venting windows and doors to dry completely
before closing them.
0ELLA#ORPORATIONISNOTRESPONSIBLEFORINTERIORPAINTANDSTAINlNISHIMPERFECTIONSFORANYPRODUCTTHATISNOTFACTORYAPPLIEDBY0ELLA
#ORPORATION5SEOFINAPPROPRIATElNISHESSOLVENTSBRICKWASHORCLEANINGCHEMICALSWILLCAUSEADVERSEREACTIONSWITHWINDOWANDDOOR
materials and voids the Limited Warranty.
&ORADDITIONALINFORMATIONONlNISHINGSEETHE0ELLA/WNERS-ANUALORGOTO www.pella.com.
EXTERIOR FINISH
4HEEXTERIORFRAMEANDSASHAREPROTECTEDBYALUMINUMCLADDINGWITHOURTOUGH%NDURA#LAD
®
OR%NDURA#LAD0LUSBAKEDONFACTORY
lNISHTHATNEEDSNOPAINTING#LEANTHISSURFACEWITHMILDSOAPANDWATER3TUBBORNSTAINSANDDEPOSITSMAYBEREMOVEDWITHMINERAL
spirits. DO NOT use abrasives. DO NOT scrape or use tools that might damage the surface.
5SEOFINAPPROPRIATElNISHESSOLVENTSBRICKWASHORCLEANINGCHEMICALSWILLCAUSEADVERSEREACTIONSWITHWINDOWANDDOORMATERIALSAND
voids the Limited Warranty.
CARE AND MAINTENANCE
#AREANDMAINTENANCEINFORMATIONISAVAILABLEINTHE0ELLA/WNERS-ANUAL9OUCANOBTAINANOWNERSMANUALBYCONTACTINGYOURLOCAL
Pella retailer. This information is also available at www.pella.com.
IMPORTANT NOTICE
"ECAUSEALLCONSTRUCTIONMUSTANTICIPATESOMEWATERINlLTRATIONITISIMPORTANTTHATTHEWALLSYSTEMBEDESIGNEDANDCONSTRUCTEDTO
properly manage moisture. Pella Corporation is not responsible for claims or damages caused by anticipated and unanticipated water
INlLTRATIONDElCIENCIESINBUILDINGDESIGNCONSTRUCTIONANDMAINTENANCEFAILURETOINSTALL0ELLAPRODUCTSINACCORDANCEWITH0ELLAS
INSTALLATIONINSTRUCTIONSORTHEUSEOF0ELLAPRODUCTSINWALLSYSTEMSWHICHDONOTALLOWFORPROPERMANAGEMENTOFMOISTUREWITHINTHE
wall systems. The determination of the suitability of all building components, including the use of Pella products, as well as the design
and installation of flashing and sealing systems are the responsibility of the Buyer or User, the architect, contractor, installer, or other
construction professional and are not the responsibility of Pella.
Pella products should not be used in barrier wall systems which do not allow for proper management of moisture within the wall systems,
SUCHASBARRIER%XTERIOR)NSULATIONAND&INISH3YSTEMS%)&3ALSOKNOWNASSYNTHETICSTUCCOOROTHERNONWATERMANAGEDSYSTEMS
%XCEPTINTHESTATESOF#ALIFORNIA.EW-EXICO!RIZONA.EVADA5TAHAND#OLORADOPella makes no warranty of any kind on and
assumes no responsibility for Pella windows and doors installed in barrier wall systems. In the states listed above, the installation
of Pella products in barrier wall or similar systems must be in accordance with Pellas installation instructions.
0RODUCTMODIlCATIONSTHATARENOTAPPROVEDBY0ELLA#ORPORATIONWILLVOIDTHE,IMITED7ARRANTY
TROUBLESHOOTING - Adjustable Strike Latching Issues
5"#4
"EKVTUBCMFTUSJLFTIJN
TJEFWJFX
4USJLF
GSPOUWJFX
"EK4USJLF4IJN
FOEWJFX
'BDUPSZ
JOTUBMMFE
TJEF
4JEFUPCF
VTFEJO
*TTVF
Issue 2:
Door needs to close more
tightly against the weather-
strip. Remove
THESTRIKEAND
ADJUSTABLESTRIKE
shim. Remove
the tabs from the
ADJUSTABLESTRIKE
shim and install
SOTHATTHETHICKER
side is visible at
THESTRIKEEDGE
2EINSTALLTHESTRIKE
Issue 1:
Door is difficult
to latch. Remove
THESTRIKEAND
ADJUSTABLESTRIKE
shim then reinstall
THESTRIKE
Note: Troubleshooting is for Architect Series
®
and Designer Series
®
only.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Pella 80KM0103 Manuale utente

Tipo
Manuale utente

in altre lingue