AndroTec Structor STR-50R Manuale utente

Categoria
Livelli laser
Tipo
Manuale utente
Instruction Manual
www.androtec.com
Universal Laser Receiver
Model: STR-50R
Art. 600335
Laser Detection at its Best
V061015
www.androtec.com
/links/detectors
For Your Safety
Safety Instructions
Please read this instruction manual
before using the device for the first
time and comply with it.
Retain this instruction manual for
future reference or for subsequent
owners.
This instruction manual is available
online under:
www.androtec.com/manuals/structor
è Only authorised and trained personnel are
allowed to repair the device. Only use genuine
spare parts from AndroTec GmbH. This ensures
continuous device safety.
è Do not look directly into the laser beam.
è Laser receiver should not be used in the
vicinity of pacemakers. The magnets produce a
field which can affect the function of the
pacemaker.
è Keep the laser receiver away from data media
and devices that react sensitive to magnetic
force. Exposure to magnets can result in
irreversible data loss.
CAUTION
Prior to the first start-up, it is definitely
necessary to carefully read the Safety
instructions!
Failure to adhere to this instruction manual and the
safety instructions may result in damage to the
device and cause dangerous situations for the
operator and other people.
In case of transport damage please inform your
vendor immediately.
è Noise emission
The a-rated sound pressure level of the acoustic
signal is >80 db (A) at a distance of one meter.
è Do not hold the laser receiver directly to your
ear!
è Keep the laser receiver away from children.
è Do not use the laser receiver in explosive
atmospheres or near flammable liquids, gases
or dust. The device may produce sparks that
can ignite vapours or dust.
è Please remove the battery if the device is not in
use for a prolonged period of time.
è Use only genuine AndroTec accessories.
When using non-recommended accessories, you
may receive incorrect measuring values.
Laser Detection at its Best
CAUTION
Do not modify the device.
Modifications can cause injuries
and malfunctions.
Page 1
Instruction Manual
Universal Laser Receiver Structor
Model: STR-50R
Laser Detection at its Best
Page 2
Instruction Manual
Universal Laser Receiver Structor
Model: STR-50R
2
3
4
5 6
6
9
8
12
10
10
13
14
7
11
Fig. A
1
1 1
1
Fig. D
Fig. C
1
2
3
12
9
10
11
8
13
14
15
16 17
1 2
7
6
3
4
5
Laser Detection at its Best
Page 3
Fig. B
Instruction Manual
Universal Laser Receiver Structor
Model: STR-50R
__________________________________________
Capture height 45 mm
__________________________________________
Reception angle ± 45°
__________________________________________
Wavelength 620 to 800nm
__________________________________________
Range with rotating laser Up to 400m (recommend-
ed speed: $ 600 rpm)
__________________________________________
Range with line laser Up to 100m (only pulsed
laser lines)
__________________________________________
Pulse freq. of line laser 4 to 11kHz
__________________________________________
Accuracy, adjustable ±0,2mm / ±1mm
/ ±2mm / ±3mm
__________________________________________
Beeper volumes High / low / off
__________________________________________
Automatic shutoff After 18min without key
stroke / laser reception
__________________________________________
Filter against Flash / sun light, LED /
fluorescent lamps
__________________________________________
Marking notch 41 mm from top edge
__________________________________________
Physical dimensions 135mm x 69mm x 25mm
__________________________________________
Weight without clamp 0,19kg
__________________________________________
Protection class IP 67 (waterproof)
__________________________________________
Power supply 1 x AA
__________________________________________
Battery life > 50 h
__________________________________________
Operating temperature -10°C to +60°C
__________________________________________
Storage temperature -40°C to +70°C
__________________________________________
Depending on the selected operating mode, the
receiver detects either the laser beams of rotating
lasers or the (horizontal or vertical) laser lines of line
lasers with hand-held receiver function, provided that
the emitted laser light is red. Any other use than the
described above shall be deemed to be improper use.
The user is liable for damage resulting from
improper use.
1 Magnet
2 LED indicator (orange)
3 LED indicator (green)
4 LED indicator (red)
5 Laser-sensitive area
6 Marking notch
7 Clamp
8 Keypad
9 Bubble vial
10 Display
11 Type plate with serial number
12 Fixing thread for the clamp
13 Beeper
14 Battery door and latch
Proper Use
Device Elements (Fig. A)
Start-Up
Technical Specifications
Avoid violent shocks or dropping the unit.
Inserting / changing the battery (Fig. A/B)
! Change the battery if is displayed .
! Open the battery cover [14].
! Remove the battery and insert a new one
(observe correct polarity!).
! Dispose of the used battery (see chapter on
environmental protection).
Laser Detection at its Best
Page 4
Instruction Manual
Universal Laser Receiver Structor
Model: STR-50R
Operation
Maintenance and Care
Keypad overview (Fig. C)
1 On / Off
2 Volume / operating mode
3 Accuracy / LED activation
Display overview (Fig. D)
1 "Rotating laser" mode
2 "Line laser" mode
3 Beeper volume: High
4 Beeper volume: Low
5 Beeper volume: Off
6 Battery low
7 Battery Ok
8 Accuracy of readings: Coarse, ± 3 mm
9 Accuracy of readings: Medium, ± 2 mm
10 Accuracy of readings: Fine, ±1 mm
11 Accuracy of readings: Extra fine, ±0,2 mm
Switching the device on / off
Press the On / Off button [1]
Adjusting the volume
! Press button [2] briefly, if necessary repeated
> Switches the beeper volume between
High / Low / Off
Selecting the operating mode
! Press button [2] for >3 seconds
Switches from rotating laser to line laser and
vice versa
Adjusting the accuracy
! Press button [3] briefly, if necessary repeated
> Switches the accuracy of readings between
Coarse / Medium / Fine / Extra fine
Activating / Deactivating the LEDs
! Press button [3] for >3 seconds
Operation
! Hold the device vertically (in case of a vertical
laser plane: horizontally) and move it towards the
laser plane.
! Please pay attention to the acoustic signals and
arrows on the (LED) display.
!
>
Display overview (fig. D)
Signs on the display Acoustic Signals
__________________________________________
12 No laser None
__________________________________________
13 Much too low Fast interval tone
__________________________________________
14 Too low Fast interval tone
__________________________________________
15 On-grade Continuous tone
__________________________________________
16 Too high Slow
__________________________________________
17 Much too high
__________________________________________
interval tone
Slow interval tone
Note
When the device is switched on, it is in
the operating mode used before it was
switched off.
! If in line laser mode, the device detects only the
line laser type which was first detected after
power on.
Keep the device always clean, especially the
laser-sensitive area!
! Do not use aggressive cleaning agents or
solvents.
! If soiled heavily the device can be cleaned under
running water.
! Do not use high-pressure cleaner.
! Allow it to dry completely before storing it in a
closed container. Residual moisture can result in
corrosion of the battery contacts. In this case our
warranty expires.
! In the unlikely event of a failure or defect, have
the appliance examined and repaired by
AndroTec.
! In all your queries and spare part orders, always
quote the 8-digit product number (see type plate)
of your device.
Laser Detection at its Best
Page 5
Instruction Manual
Universal Laser Receiver Structor
Model: STR-50R
Do not dispose of the device with domes-
tic waste. Have the device disposed of by
an authorised waste management
company or your municipal waste mana-
gement organisation.
Adhere to the applicable regulations. In case of doubt
contact your waste management organisation.
Recycle all packaging material in an environmentally
friendly manner.
Batteries:
Do not dispose of batteries with domestic waste, do
not expose them to fire or water. Collect and recycle
batteries or dispose them with due care for the
environment.
Environmental Protection
Warranty
AndroTec Structor and clamp are warranted to be
free of defects in material and workmanship accor-
ding to the statutory warranty regulations.
The user of the product is expected to follow all
operating, maintenance and care instructions. Any
evidence of misuse, alteration, or an attempt to repair
products by unauthorized personnel, or use of parts
other than those provided by AndroTec GmbH
automatically voids the warranty.
AndroTec grants an extended warranty for a period of
three years if within six weeks from the date of
purchase the warranty registration card is filled out
and returned to AndroTec or the product is registered
via Internet at www.androtec.com. Please make sure
that the registration is filled out properly and on file
with AndroTec.
This warranty period is thirty-six months from the
date the new product is delivered from the dealer to
the purchaser or is put into service by a dealer as a
demonstration unit or rental unit. Competitor purcha-
sed and tested units are excluded from this warranty.
AndroTec may choose to repair or replace, at its
discretion, any Structor in the event of a failure for
any reason, during the warranty period. In case of a
warranty claim, return the product and a proof of
purchase to the factory.
AndroTec's liability under this warranty is limited to
We herewith declare that this product conforms with
the following standards and directives:
Standards
· DIN EN 61000-6-1
· DIN EN 61000-6-3
in accordance with the regulations stipulated in the
directives:
EC Directive
· 2004/108/EG
· 2006/95/EG
Technical Documentation at:
AndroTec GmbH
Dr.-Ing. Klaus W. Jörg
General Manager
AndroTec GmbH
Waldfischbach-Burgalben, 22.08.2014
Technical changes reserved.
We accept no liability for printing errors.
Declaration of Conformity
Laser Detection at its Best
Page 6
AndroTec GmbH
Hauptstraße 186
67714 Waldfischbach-Burgalben
Federal Republic of Germany
www.androtec.com
WEEE-Reg.No.: DE37015608
Manufacturer
repairing or replacing any product returned to its
factory for that purpose. The foregoing states the
entire liability of AndroTec GmbH regarding the
purchase and use of its product and they shall not be
held responsible for any consequential loss or
damage of any kind. This warranty is in lieu of all
other warranties, expressed or implied, and constitu-
tes all of AndroTec GmbH liability with respect to
merchandise sold by it.
Warranty is strictly related to repair or substitution of
defective parts according to AndroTec's discretion.
The warranty does not cover any other damage that
may occur directly or indirectly using defective parts.
Instruction Manual
Universal Laser Receiver Structor
Model: STR-50R
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7