Elation COLOUR CHORUS Series Manuale utente

Categoria
Stroboscopi
Tipo
Manuale utente
COLOUR CHORUS 72
user manual
ELATION
|
COLOUR CHORUS 72
|
user manual
www.elationlighting.com
2 COLOUR CHORUS 72™ User Manual Version 1
©2015 ELATION PROFESSIONAL all rights reserved. Information, specifications,
diagrams, images, and instructions herein are subject to change without notice.
ELATION PROFESSIONAL logo and identifying product names and numbers herein
are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes
all forms and matters of copyrightable materials and information now allowed by
statutory or judicial law or hereinafter granted. Product names used in this
document may be trademarks or registered trademarks of their respective
companies and are hereby acknowledged. All non-ELATION brands and product
names are trademarks or registered trademarks of their respective companies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all
liabilities for property, equipment, building, and electrical damages, injuries to any
persons, and direct or indirect economic loss associated with the use or reliance of
any information contained within this document, and/or as a result of the improper,
unsafe, insufficient and negligent assembly, installation, rigging, and operation of
this product.
DOCUMENT VERSION
Please check www.elationlighting.com for the latest revision/update of this manual.
Date
Document
Version
Software
Version
DMX
Channel Modes
Notes
9/20/15 1
1.10
3 / 4 / 5 / 6 / 9 / 10 / 11 / 36 / 38 / 43 / 45 / 48 / 49 / 53 Updated Format.
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com
www.elationlighting.com
3 COLOUR CHORUS 72™ User Manual Version 1
CONTENTS
General Information
4
Warranty
6
Safety Instructions
7
General Guidelines
8
Fixture Overview
9
Fixture Installation
10
Fixture Menu
12
DMX Channel Functions And Values
15
Cleaning and Maintenance
26
Technical Specifications
27
Optional Accessories
29
www.elationlighting.com
4 COLOUR CHORUS 72™ User Manual Version 1
GENERAL INFORMATION
INTRODUCTION
Congratulations, you have just purchased one of the most innovative and
reliable lighting fixtures on the market today! The fixture has been designed to
perform reliably for years when the guidelines in this booklet are followed. Please
read and understand the instructions in this manual carefully and thoroughly
before attempting to operate this unit. These instructions contain important
information regarding safety during use and maintenance.
UNPACKING
Every fixture has been thoroughly tested and has been shipped in perfect
operating condition. Carefully check the shipping carton for damage that may
have occurred during shipping. If the carton appears to be damaged, carefully
inspect your unit for damage and be sure all accessories necessary to operate
the unit have arrived intact. In the event damage has been found or parts are
missing, please contact our customer support team for further instructions. Please
do not return this unit to your dealer without first contacting customer support at
the number listed below. Please do not discard the shipping carton in the trash.
Please recycle whenever possible.
BOX CONTENTS
(1) powerCON Cable
Manual & Warranty Card
www.elationlighting.com
5 COLOUR CHORUS 72™ User Manual Version 1
CUSTOMER SUPPORT
Elation Professional® provides a customer support line, to provide set up help and
to answer any question should you encounter problems during your set up or
initial operation. You may also visit us on the web at www.elationlighting.com for
any comments or suggestions. For service related issue please contact Elation
Professional®.
ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST
Voice: 323-582-3322 Fax: 323-832-9142
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 30 Fax: +31 45 546 85 96
WARRANTY REGISTRATION
Please complete and mail in the enclosed warranty card or register online:
http://www.elationlighting.com/Login.aspx to validate your purchase. All
returned service items whether under warranty or not, must be freight pre-paid
and accompany a return authorization (R.A.) number. The R.A. number must be
clearly written on the outside of the return package. A brief description of the
problem as well as the R.A. number must also be written down on a piece of
paper and included in the shipping container. If the unit is under warranty, you
must provide a copy of your proof of purchase invoice. Items returned without a
R.A. number clearly marked on the outside of the package will be refused and
returned at customer’s expense. You may obtain a R.A. number by contacting
customer support.
IMPORTANT NOTICE!
There are no user serviceable parts inside this unit. Do not attempt any repairs
yourself; doing so will void your manufactures warranty. Damages resulting from
modifications to this fixture and/or the disregard of safety and general user
instructions found in this user manual void the manufactures warranty and are
not subject to any warranty claims and/or repairs.
www.elationlighting.com
6 COLOUR CHORUS 72™ User Manual Version 1
LIMITED WARRANTY
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to
be free of manufacturing defects in material and workmanship for a period of two years (730 days),
and Elation Professional® product rechargeable batteries to be free of manufacturing defects in
material and workmanship for a period of six months (180 days), from the original date of purchase.
This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only
if the product is purchased within the United States of America, including possessions and territories. It
is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at
the time service is sought.
B. For warranty service, send the product only to the Elation Professional® factory. All shipping
charges must be pre-paid. If the requested repairs or service (including parts replacement) are within
the terms of this warranty, Elation Professional® will pay return shipping charges only to a designated
point within the United States. If any product is sent, it must be shipped in its original package and
packaging material. No accessories should be shipped with the product. If any accessories are
shipped with the product, Elation Professional® shall have no liability what so ever for loss and/or or
damage to any such accessories, nor for the safe return thereof.
C. This warranty is void if the product serial number and/or labels are altered or removed; if the
product is modified in any manner which Elation Professional® concludes, after inspection, affects
the reliability of the product; if the product has been repaired or serviced by anyone other than the
Elation Professional® factory unless prior written authorization was issued to purchaser by Elation
Professional®; if the product is damaged because not properly maintained as set forth in the product
instructions, guidelines and/or user manual.
D. This is not a service contract, and this warranty does not include any maintenance, cleaning or
periodic check-up. During the periods as specified above, Elation Professional® will replace
defective parts at its expense, and will absorb all expenses for warranty service and repair labor by
reason of defects in material or workmanship. The sole responsibility of Elation Professional® under
this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at
the sole discretion of Elation Professional®. All products covered by this warranty were manufactured
after January 1, 1990, and bare identifying marks to that effect.
E. Elation Professional® reserves the right to make changes in design and/or performance
improvements upon its products without any obligation to include these changes in any products
theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory
supplied with the products described above. Except to the extent prohibited by applicable law, all
implied warranties made by Elation Professional® in connection with this product, including
warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above.
And no warranties, whether expressed or implied, including warranties of merchantability or fitness,
shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole
remedy shall be such repair or replacement as is expressly provided above; and under no
circumstances shall Elation Professional® be liable for any loss and/or damage, direct and/or
consequential, arising out of the use of, and/or the inability to use, this product.
G. This warranty is the only written warranty applicable to Elation Professional® products and
supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
www.elationlighting.com
7 COLOUR CHORUS 72™ User Manual Version 1
SAFETY INSTRUCTIONS
This fixture
is an extremely sophisticated piece of electronic equipment. To
guarantee a smooth operation, it is important to follow the guidelines in this
manual. The manufacturer of this device will not accept responsibility for
damages resulting from the misuse of
this fixture due to the disregard of the
information printed in this manual.
This device falls under PROTECTION CLASS 1
. It’s essential this device be
grounded properly. Only qualified personnel should
perform all electrical
connections.
INDOORS USE ONLY!
DO NOT EXPOSE FIXTURE RAIN AND MOISTURE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT!
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
For proper operation, follow the Installation guidelines described in this manual. Only qualified
and certified personnel should perform installation of this fixture and only the original rigging parts
(brackets) included with this fixture should be used for installation. Any modifications will void the
original manufactures warranty and increase the risk of damage and/or personal injury.
Never look directly into the light source of this fixture to prevent risk of injury to your retina, which
may induce blindness. Those suffering from EPILEPSY should avoid looking directly into the light
source of this unit at all times.
The fan and air inlets must remain clean and never blocked. Allow approx. 6” (15cm) between
this fixture and other devices or a wall for proper cooling.
Always disconnect from main power source before performing any type of service and/or
cleaning procedure. Only handle the power cord by the plug end, never pull out the plug by
tugging the wire portion of the cord.
Do not operate this fixture if the power cord has become frayed, crimped and/or damaged. If
the power cord is damaged, replace it immediately with a new one of similar power rating.
www.elationlighting.com
8 COLOUR CHORUS 72™ User Manual Version 1
GENERAL GUIDELINES
NEVER OPEN THIS FIXTURE WHILE IN USE!
During the initial operation of this fixture, a light smoke or smell may emit from the
interior of the fixture. This is a normal process and is caused by excess paint in the
interior of the casing burning off from the heat associated with the lamp and will
decrease gradually over time.
This fixture is a professional lighting effect designed for INDOOR / DRY LOCATIONS
ONLY on stage, in nightclubs, theatres, etc.
Please make sure there are NO FLAMMABLE MATERIALS close to the fixture while
operating, to prevent any fire hazard.
The fixture must be installed in a location with adequate ventilation, at least 1.5
feet (.5m) from adjacent surfaces. Be sure no air ventilation slots are blocked.
DO NOT attempt installation and/or operation without knowledge how to do so.
DO NOT permit operation by persons who are not qualified to operate this type
of fixture. Most damages are the result of operations by nonprofessionals.
Consistent operational breaks may ensure the fixture will function properly for
many years to come.
DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
Always install the fixture with an appropriate safety cable. When installing the
fixture in a suspended environment, always use mounting hardware that is no less
than M10 x 25 mm, also be sure the hardware is insert in the pre-arranged screw
holes in the bracket of the fixture.
Use the original packaging and materials to transport the fixture in for service.
DO NOT TOUCH the housing bare-hand during its operation. Turn OFF the power
and allow approximately 15 minutes for the fixture to cool down before replacing
or serving.
www.elationlighting.com
9 COLOUR CHORUS 72™ User Manual Version 1
FIXTURE OVERVIEW
1. 3pin DMX IN
2. 5pin DMX IN
3. powerCON IN
4. LCD Menu Control Display
5. RJ45 NET IN
6. RJ45 NET OUT
7. powerCON OUT
8. 3pin DMX OUT
9. 5pin DMX OUT
10. MODE Button
11. UP Button
12. DOWN Button
13. ENTER Button
www.elationlighting.com
10 COLOUR CHORUS 72™ User Manual Version 1
FIXTURE INSTALLATION
FLAMMABLE MATERIAL WARNING
Keep fixture at least 5.0 ft.
(1.5m) away from any
flammable materials, decorations, pyrotechnics, etc.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all
electrical connections and/or installations.
CAUTIONS
For added protection, mount the fixture in areas outside walking paths, seating
areas, or in areas were unauthorized personnel might reach the fixture.
Ambient operating temperature range for this fixture is 5°F to 113°F (-15°C to 45°C).
Do not use the fixture under or above this temperature.
Before mounting the fixture to any surface, make sure the installation area can
hold a minimum point load of 10 times the weight of the fixture.
Fixture installation must always be secured with a secondary safety attachment,
such as an appropriate safety cable.
Never stand directly below the device when mounting, removing or servicing.
POWER LINKING
Max number of units that can be power linked is 0 units @110V and 3 units @240V.
CLAMP MOUNTING
The fixture provides integrated and adjustable rigging brackets. When mounting this
fixture to truss be sure to secure an appropriately rated clamps to the rigging
brackets using a M10 screw fitted through the center hole.
www.elationlighting.com
11 COLOUR CHORUS 72™ User Manual Version 1
MOUNTING POINTS
Overhead mounting requires extensive experience, including amongst others
calculating working load limits, installation material being used, and periodic
safety inspection of all installation material and the device. If you lack these
qualifications, do not attempt the installation yourself. Improper installation can
result in bodily injury.
Fixture is fully operational in the specific mounting positions as illustrated below.
SAFETY CABLE
Always use a Safety Cable whenever installing this fixture in a suspended
environment to ensure the fixture will not drop if the clamp fails.
www.elationlighting.com
12 COLOUR CHORUS 72™ User Manual Version 1
FIXTURE MENU
ON-BOARD SYSTEM MENU
The fixture comes with an easy to navigate system menu. The next section will
detail the functions of each command in the system menu.
LCD MENU CONTROL PANEL
The control panel (see image below) located on the back of the fixture allows you
to access the main menu and make all necessary adjustments to the fixture. During
normal operation, pressing MODE button once will access the fixture’s main menu.
Once in the main menu you can navigate through the different functions and
access the sub-menus with the UP, and DOWN buttons. Once you reach a field that
requires adjusting, press the ENTER button to activate that field and use the UP and
DOWN buttons to adjust the field. Pressing the ENTER button once more will confirm
your setting. You may exit the main menu at any time without making any
adjustments by pressing the MODE button.
NOTE: the LCD Menu Control Display will shut OFF and lockout after 30 seconds of no
use. Press and hold the MODE button for 10 seconds to unlock the LCD display.
INFORMATION DISPLAYED DURING INITIAL POWER ON
When the fixture is initially powered ON, the display shows the following information:
Software Update
Please Wait...
CC72
ADDR:001 MOD:01
www.elationlighting.com
13 COLOUR CHORUS 72™ User Manual Version 1
ELATION© COLOUR CHORUS 72™
S Y S T E M M E N U
Specifications are subject to change without any prior written notice.
Default Settings in BOLD.
MENU
OPTIONS / VALUES
DESCRIPTION
Set Address
ADDR:001 - XXX Set DMX Address.
User Mode
Refer to the DMX CHANNEL MODE TABLE on page 15 Set User Mode.
Effect
Programs 1-12
Program Speed
0-255
Program Fade 0-255
Macros 0-255 (64 Total Color Macros) See DMX Traits for Values.
Manual R
Manual G
Manual B
Manual A
0-255
0-255
0-255
0-255
Function
Status
Remote DMX Addrs: ON / OFF
No DMX Mode: Blackout / Hold / Program
Fixture ID
Service PIN
RDM PID
Device IP Addr
Ctrl IP Addr
Universe
Password = 050
XXXXXX
XXX.XXX.XXX.XXX
XXX.XXX.XXX.XXX
XXX
Protocol Set
Kling-Net, ArtNet
Net Switch ON / OFF
Fan Set LED Fan
Auto
High
Low
LCD. Set
Display
Key Lock
DispFlash
ON / OFF
ON / OFF
ON / OFF
Temp. C/F
Celsius
Fahrenheit
Dim. Curve
Standard, Stage, TV, Architectural,
Theatre
Set desired Dimming Curve.
Pixel Flip
Standard / Flip
Set starting LED Group.
See Pixel Flip Section.
Intensity Mode Standard / High Output
Reset to Default OFF / ON
Information
Time. Info
Current
Total Time
Last Clear
Timer PIN
Clear Last
Temp. Info LED Temp.
Model. Info Colour Chorus 72
Software.V 1.10
www.elationlighting.com
14 COLOUR CHORUS 72™ User Manual Version 1
DIMMING CURVES
The DimCurve menu allows you to select one of the following preset dimming curves:
Standard, Stage, TV, Architectural, Theatre, or Default.
(See diagram below for more details)
Dimmer
PIXEL FLIP
Select the desired starting LED Group direction from one of the following modes below via
UP/DOWN buttons and then press ENTER to confirm.
STANDARD FLIP
www.elationlighting.com
15 COLOUR CHORUS 72™ User Manual Version 1
DMX CHANNEL FUNCTIONS AND VALUES
Please refer to the table below to find the corresponding MOD # for each
DMX Channel Mode listed in the following DMX traits.
DMX CHANNEL MODE TABLE
MOD#
01 02 03 04 05 06 07 08 09
DMXCH
MODE
HSI
3CH
DA
3CH
HSI+
4CH
RGBA
4CH
DA+
5CH
sRGBI
5CH
RGBA+
6CH
sRGBI
9 CH
fxHSI
9CH
MOD#
10 11 12 13 14 15 16 17 18 19
DMXCH
MODE
sRGBI+
10CH
fxHSI+
11CH
DA
36CH
HSI
36CH
DA+
38CH
fxHSI
43CH
fxHSI+
45CH
RGBA
48CH
sRGBI
49CH
sRGBI+
53CH
www.elationlighting.com
16 COLOUR CHORUS 72™ User Manual Version 1
ELATION© COLOUR CHORUS 72™
DMX Channel Values / Functions Version 1 (53 DMX Channels)
Specifications are subject to change without any prior written notice.
*Control of LED Modules depends on the Pixel Flip setting.
MOD# / DMX CHANNEL MODE VALUE FUNCTION
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19
1 1
LED GROUP 1-12*
0-1
GROUP 1
2-5
GROUP 2
6-7
GROUP 3
8-9
GROUP 4
10-11
GROUP 5
12-13
GROUP 6
14-17
GROUP 7
18-19
GROUP 8
20-21
GROUP 9
22-23
GROUP 10
24-25
GROUP 11
26-27
GROUP 12
28-115
NO Function
116
Between GROUP 1
117-120
Between GROUP 2
121-122
Between GROUP 3
123-124
Between GROUP 4
125-126
Between GROUP 5
127-128
Between GROUP 6
129-132
Between GROUP 7
133-134
Between GROUP 8
135-136
Between GROUP 9
137-138
Between GROUP 10
139-140
Between GROUP 11
141-142
Between GROUP 12
143-207
NO Function
208-211
Interval GROUP 1
212-213
Interval GROUP 2
214-215
Interval GROUP 3
216-217
Interval GROUP 4
218-219
Interval GROUP 5
220-223
Interval GROUP 6
224-225
Interval GROUP 7
226-227
Interval GROUP 8
228-229
Interval GROUP 9
230-231
Interval GROUP 10
232-233
Interval GROUP 11
234-255
NO Function
www.elationlighting.com
17 COLOUR CHORUS 72™ User Manual Version 1
ELATION© COLOUR CHORUS 72™
DMX Channel Values / Functions Version 1 (53 DMX Channels)
Specifications are subject to change without any prior written notice.
*Control of LED Modules depends on the Pixel Flip setting.
MOD# / DMX CHANNEL MODE VALUE FUNCTION
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19
1 1 2 2
COLOR SPEED
0-255 Color Speed SLOW TO FAST
2 2 3 3
COLOR FAN
0-255 Variable Color Fan MIN to MAX
3 3 4 4
COLOR RANGE
0-255 Adjust Color Spectrum
4 4 5 5
COLOR STEP
0-254 Step to Fade Color Scroll Control
255 Switch to RGB
1
1 5 1 5
6 6
1 1
STROBE
0-31 NO Function
32-95 Variable Strobe Effect SLOW to FAST
96-127 LEDs ON
128-159 Pulse Effect In Sequence SLOW to FAST
160-191 LEDs ON
192-223 Random Strobe Effect SLOW to FAST
224-255 LEDs ON
6 6 7 7
FAN INTENSITY
0-255 Alternating Groups ON / OFF
1 1 7 7
HUE
0-255 0 to 100%
2 2 8 8
SATURATION
0-255 0 to 100%
3 3 9 9
INTENSITY
0-255 0 to 100%
1 1 1 2 1 2 2
RED
0-255 0 to 100%
2 2 2 3 2 3 3
GREEN
0-255 0 to 100%
3 3 3 4 3 4 4
BLUE
0-255 0 to 100%
4 4
AMBER
0-255 0 to 100%
4 5 5 5 5 10
MASTER DIMMER
0-255 Intensity 0 to 100%
www.elationlighting.com
18 COLOUR CHORUS 72™ User Manual Version 1
ELATION© COLOUR CHORUS 72™
DMX Channel Values / Functions Version 1 (53 DMX Channels)
Specifications are subject to change without any prior written notice.
*Control of LED Modules depends on the Pixel Flip setting.
MOD# / DMX CHANNEL MODE VALUE FUNCTION
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19
6 6
PROGRAMS
0-19 NO FUNCTION
20-39 Program 1
40-59 Program 2
60-79 Program 3
80-99 Program 4
100-119 Program 5
120-139 Program 6
140-159 Program 7
160-179 Program 8
180-199 Program 9
200-219 Program 10
220-239 Program 11
240-255 Program 12
7 7
PROGRAM SPEED
0-255 Program Speed SLOW to FAST
8 8
PROGRAM FADE
0-255 Program Fade SLOW to FAST
9 9
COLOR MACROS
1-4 Color Macro 01
5-8 Color Macro 02
9-12 Color Macro 03
13-16 Color Macro 04
17-20 Color Macro 05
21-24 Color Macro 06
25-28 Color Macro 07
29-32 Color Macro 08
33-36 Color Macro 09
37-40 Color Macro 10
41-44 Color Macro 11
45-48 Color Macro 12
49-52 Color Macro 13
53-56 Color Macro 14
57-60 Color Macro 15
61-64 Color Macro 16
65-68 Color Macro 17
69-72 Color Macro 18
73-76 Color Macro 19
77-80 Color Macro 20
www.elationlighting.com
19 COLOUR CHORUS 72™ User Manual Version 1
ELATION© COLOUR CHORUS 72™
DMX Channel Values / Functions Version 1 (53 DMX Channels)
Specifications are subject to change without any prior written notice.
*Control of LED Modules depends on the Pixel Flip setting.
MOD# / DMX CHANNEL MODE VALUE FUNCTION
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19
9 9
81-84 Color Macro 21
85-88 Color Macro 22
89-92 Color Macro 23
93-96 Color Macro 24
97-100 Color Macro 25
101-104 Color Macro 26
105-108 Color Macro 27
109-112 Color Macro 28
113-116 Color Macro 29
117-120 Color Macro 30
121-124 Color Macro 31
125-128 Color Macro 32
129-132 Color Macro 33
133-136 Color Macro 34
137-140 Color Macro 35
141-144 Color Macro 36
145-148 Color Macro 37
149-152 Color Macro 38
153-156 Color Macro 39
157-160 Color Macro 40
161-164 Color Macro 41
165-168 Color Macro 42
169-172 Color Macro 43
173-176 Color Macro 44
177-180 Color Macro 45
181-184 Color Macro 46
185-188 Color Macro 47
189-192 Color Macro 48
193-196 Color Macro 49
197-200 Color Macro 50
201-204 Color Macro 51
205-208 Color Macro 52
209-212 Color Macro 53
213-216 Color Macro 54
217-220 Color Macro 55
221-224 Color Macro 56
225-228 Color Macro 57
229-232 Color Macro 58
233-236 Color Macro 59
237-240 Color Macro 60
241-244 Color Macro 61
245-248 Color Macro 62
249-252 Color Macro 63
253-255 Color Macro 64
www.elationlighting.com
20 COLOUR CHORUS 72™ User Manual Version 1
ELATION© COLOUR CHORUS 72™
DMX Channel Values / Functions Version 1 (53 DMX Channels)
Specifications are subject to change without any prior written notice.
*Control of LED Modules depends on the Pixel Flip setting.
MOD# / DMX CHANNEL MODE VALUE FUNCTION
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19
1 1 1 2 2
RED - LED GROUP 1*
0-255 0 to 100%
2 2 2 3 3
GREEN - LED GROUP 1*
0-255 0 to 100%
3 3 3 4 4
BLUE - LED GROUP 1*
0-255 0 to 100%
4
AMBER - LED GROUP 1*
0-255 0 to 100%
5 5
INTENSITY - LED GROUP 1*
0-255 0 to 100%
4 4 5 6 6
RED - LED GROUP 2*
0-255 0 to 100%
5 5 6 7 7
GREEN - LED GROUP 2*
0-255 0 to 100%
6 6 7 8 8
BLUE - LED GROUP 2*
0-255 0 to 100%
8
AMBER - LED GROUP 2*
0-255 0 to 100%
9 9
INTENSITY - LED GROUP 2*
0-255 0 to 100%
7 7 9 10 10
RED - LED GROUP 3*
0-255 0 to 100%
8 8 10 11 11
GREEN - LED GROUP 3*
0-255 0 to 100%
9 9 11 12 12
BLUE - LED GROUP 3*
0-255 0 to 100%
12
AMBER - LED GROUP 3*
0-255 0 to 100%
13 13
INTENSITY - LED GROUP 3*
0-255 0 to 100%
10 10 13 14 14
RED - LED GROUP 4*
0-255 0 to 100%
11 11 14 15 15
GREEN - LED GROUP 4*
0-255 0 to 100%
12 12 15 16 16
BLUE - LED GROUP 4*
0-255 0 to 100%
16
AMBER - LED GROUP 4*
0-255 0 to 100%
17 17
INTENSITY - LED GROUP 4*
0-255 0 to 100%
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30

Elation COLOUR CHORUS Series Manuale utente

Categoria
Stroboscopi
Tipo
Manuale utente

in altre lingue