ProLights ECLPARFC Manuale utente

Categoria
Stroboscopi
Tipo
Manuale utente
EN - IT
USER MANUAL
MANUALE UTENTE
ECLPARFC
LED PROJECTOR
All rights reserved by Music & Lights S.r.l. No part of this instruction manual may be
reproduced in any form or by any means for any commercial use.
In order to improve the quality of products, Music&Lights S.r.l. reserves the right to modify the
characteristics stated in this instruction manual at any time and without prior notice.
All revisions and updates are available in the ‘manuals section on site www.musiclights.it
REV. 02-07/19
1
ECLPARFC
Packing content
ECLPARFC
User manual
Power cable
Additional optics: 24° (included), 65° lens (included)
Gel frame holder included
TABLE OF
CONTENTS
Safety
General instructionsGeneral instructions
Warnings and installation precautionsWarnings and installation precautions
1 Introduction
1. 1 Description and specications1. 1 Description and specications
1. 2 Operating elements and connections1. 2 Operating elements and connections
2 Installation
2. 1 Mounting2. 1 Mounting
3 Functions and settings
3. 1 Operation3. 1 Operation
3. 2 Basic3. 2 Basic
3. 3 Menu structure3. 3 Menu structure
3. 4 DMX mode3. 4 DMX mode
3. 5 DMX conguration3. 5 DMX conguration
3. 6 Channels DMX3. 6 Channels DMX
3. 7 Screen3. 7 Screen
3.8 Fixture settings3.8 Fixture settings
Dimmer Dimmer
Led frequency Led frequency
Fan mode Fan mode
Factory Reload Factory Reload
3. 9 Fixture Information3. 9 Fixture Information
3. 10 Operations in automatic mode3. 10 Operations in automatic mode
Master/Slave Master/Slave
Eects Eects
Static Mode Static Mode
4 Maintenance
4. 1 Maintenance and cleaning the unit4. 1 Maintenance and cleaning the unit
4. 2 Trouble shooting4. 2 Trouble shooting
2
2
3
5
6
7
7
8
10
10
11
16
16
16
16
16
16
17
17
17
17
17
18
18
2
ECPARFC
SAFETY
General instruction
The products referred to in this manual conform to the European Community Directives and are there-
fore marked with .
The unit is supplied with hazardous network voltage (230V~). Leave servicing to skilled personnel only.
Never make any modications on the unit not described in this instruction manual, otherwise you will
risk an electric shock.
Connection must be made to a power supply system tted with ecient earthing (Class I appliance ac-
cording to standard EN 60598-1). It is, moreover, recommended to protect the supply lines of the units
from indirect contact and/or shorting to earth by using appropriately sized residual current devices.
The connection to the main network of electric distribution must be carried out by a qualied electrical
installer. Check that the main frequency and voltage correspond to those for which the unit is designed
as given on the electrical data label.
This unit is not for home use, only professional applications.
Never use the xture under the following conditions:
- in places wet;
- in places subject to vibrations or bumps;
- in places with a temperature of over 45 °C.
Make certain that no inammable liquids, water or metal objects enter the xture.
Do not dismantle or modify the xture.
All work must always be carried out by qualied technical personnel. Contact the nearest sales point for
an inspection or contact the manufacturer directly.
If the unit is to be put out of operation denitively, take it to a local recycling
plant for a disposal which is not harmful to the environment.
Warnings and installation precautions
If this device will be operated in any way dierent to the one described in this manual, it may suer
damage and the guarantee becomes void. Furthermore, any other operation may lead to dangers like
short circuit, burns, electric shock, etc.
Before starting any maintenance work or cleaning the projector, cut o power from the main supply.
Always additionally secure the projector with the safety rope. When carrying out any work, always com-
ply scrupulously with all the regulations (particularly regarding safety) currently in force in the country
in which the xture’s being used.
Install the xture in a well ventilated place.
Keep any inammable material at a safe distance from the xture.
Shields, lenses or ultraviolet screens shall be changed if they have become damaged to such an extent
that their eectiveness is impaired.
The lamp (LED) shall be changed if it has become damaged or thermally deformed.
Never look directly at the light beam. Please note that fast changes in lighting, e. g. ashing light, may
trigger epileptic seizures in photosensitive persons or persons with epilepsy.
Do not touch the product’s housing when operating because it may be very hot.
This product was designed and built strictly for the use indicated in this documentation. Any other use,
not expressly indicated here, could compromise the good condition/operation of the product and/or
be a source of danger.
We decline any liability deriving from improper use of the product.
WARNING! Before carrying out any operations with the unit, carefully read this instruction
manual and keep it with cure for future reference. It contains important information about
the installation, usage and maintenance of the unit.
3
ECLPARFC
- 1 - INTRODUCTION
1.1 ECLPARFC - DESCRIPTION AND TECHNICAL SPECIFICATIONS
EclipsePAR is a range of multipurpose LED xtures with a single source, delivering silent operation, high
quality of light and optical exibility, designed to redene the standard for theatrical, TVs and corporate
applications.
EclipsePARFC features a 150W RGB + warm white and delivers a superior white CTC with +/- tint control,
Red-shift (CRI>92 and R9>94) and colour mixing.
The xture includes an extensive range of accessories including barn doors, lter frame, egg crate and a
multitude of interchangeable lenses.
EclipsePAR features a smooth 16-bit dimming as well as RDM control and adjustable PWM providing eye-
candy.
LIGHT SOURCE
Source: 150W RGB + warm white
CT: 2800K - 10000K
CRI: > 92
R9: > 94
Luminous ux: (40°) 5720 lm - (65°) 5130.8lm @Full
Lux: (40°) 2890 lux - (65°) 490lux @3m full
Lux: (40°) 1040.4 lux - (65°) 176.4lux @5m full
Source life expectancy: >50.000 h
Other: TM-30-15RF/RG: 90/99 - TLCI: >85
OPTICS
Beam angle: (on board) 24° or (included) 65°
Field angle: (on board) 41° or (included) 100°
Lens diameter: 163mm
Lens type: fresnel lens
Additional optics: 24° lens on board - 65° lens included- 40° lens optional - egg crate optional - barn-
doors optional - gel frame holder included
Other: 12° lens not available
COLOUR SYSTEM
Colour mixing: RGB+Warm White
CTC: CTC control through independent DMX channel, plus/minus green and magenta correction and
amber shift activation by DMX
White presets: 2800K-6500K
Colour wheel: virtual colour wheel with presets
Macros: built-in white presets
DYNAMIC EFFECTS
Static colour mode: selection of static colour
Manual colour mode: manual adjustment of colour
Auto mode: built-in programs with execution speed adjustment
Special features: linear crossfade from a white to any color and CTO applied on colors
BODY
Hardware on-board: on board mechanics for rigging to the ceiling
Body: sturdy die-cast aluminium body conceived for long-time durability
Body colour: black
4
ECPARFC
Fig.1 Technical drawing
CONTROL
Protocols: DMX512, RDM
DMX channels: (theatre) 1 / 2 / 4 / 5 / 6 / 10 / 15 / 17 ch - (tour) 4 / 6 / 10 / 15channel
RDM: RDM ready for xture remote monitor and settings
Display: black OLED high resolution display
Firmware upgrade: yes, via USB-DMX interface (UPBOX1) not included
Master/Slave: for synchronized operation of more units linked in a chain
ELECTRONICS
Dimmer: linear 0~100% electronic dimmer
Dimmer curves: 4 dierent dimming curves available
Strobe / shutter: 1-30 Hz, electronic
Operating temperature: -10° ~ +45°
Flicker: icker free operation
Selectable PWM: 600~25K Hz
ELECTRICAL
Power consumption: 320W
Power supply: 100-240V – 50/60Hz
Power consumption (at 230V): 148.7W
Power consumption (at 120V): 152.5W
Output (at 230V): 14 units on a single power line
Output (at 120V): 7 units on a single power line
Power factor: pF 0.99 @ 120V - pF 0.94 @ 230V
PHYSICAL
Cooling: forced air with low noise fan
Sospension and xing: any position with quick-lock omega brackets
Signal connection: Amphenol XLR 3p + 5p IN/OUT connectors
Power connection: Neutrik powerCON IN/OUT connectors
IP rating: 20
Dimensions (WxHxD): 316x404x317mm
Weight: 5.7kg
316mm/12,44in 318mm/12,52in
404mm/15,91in
ECLPARFC
11
3
2
8
10
9
5
6
7
4
Fig.2
5
ECLPARFC
1.2 OPERATING ELEMENTS AND CONNECTIONS
1. LOCKING KNOB for mounting bracket.
2. MOUNTING BRACKET.
3. CONTROL PANEL with display and 4 button
used to access the control panel functions
and manage them.
4. DMX IN (3-pole XLR): 1 = ground, 2 = DMX -,
3 = DMX +.
5. DMX OUT (3-pole XLR): 1= ground, 2 = DMX
-, 3 = DMX +.
6. DMX IN (5-pole XLR): 1 = ground, 2 = DMX-, 3
= DMX+, 4 N/C, 5 N/C.
7. DMX OUT (5-pole XLR): 1 = ground, 2 = DMX-,
3 = DMX+, 4 N/C, 5 N/C.
8. POWER IN (PowerCON IN): for connection to a
socket (100-240V~/50-60Hz) via the supplied
mains cable.
9. MAIN FUSE HOLDER: replace a burnt-out fuse
by one of the same type only.
10. POWER OUT (PowerCON OUT): power output
for connection of multiple units in series.
Fig.3
6
ECPARFC
- 2 - INSTALLATION
2.1 MOUNTING
ECLPARFC may be set up on a solid and even surface. The unit can also be mounted upside down to a cross
arm. For xing, stable mounting clips are required. The mounting place must be of sucient stability and
be able to support a weight of 10 times of the unit’s weight.
When carrying out any installation, always comply scrupulously with all the regulations (particularly re-
garding safety) currently in force in the country in which the xture’s being used.
Install the projector at a suitable location by means of the mounting bracket .
Always additionally secure the projector with the safety rope from falling down. For this purpose, fas-
ten the safety rope at a suitable position so that the maximum fall of the projector will be 20 cm.
Adjust the projector and use the knob to slightly release or tighten the locking mechanism of the
bracket if is necessary .
NOTE - For the installation of the projector ECLPARFC insert the hook to stare it to a suspended system.
MENU UP DOWN ENTER
Used to access the menu or
to return a previous menu
option
Navigates downwards through
the menu list and increases
the numeric value when in a
function
Navigates upwards through
the menu list and decreases
the numeric value when in
a function
Used to select and store the
current menu or conrm the
current function value or
option within a menu
7
ECLPARFC
- 3 - FUNCTIONS AND SETTINGS
3.1 OPERATION
To turn on the ECLPARFC connect the supplied main cable to a socket (100-240 VAC-50/60 Hz). Then the
unit is ready for operation and can be operated via a DMX controller or it independently performs its show
program in succession.
To switch o, disconnect the mains plug from the socket. For a more convenient operation it is recom-
mended to connect the unit to a socket which can be switched on and o via a light switch.
It is the responsibility of the installer to ensure the electrical, mechanical and thermal compatibility of the
track system and the ttings. The connection to the main network of electric distribution must be carried
out by a qualied electrical installer.
ATTENTION - Make sure to remove the tension of feeding before beginning any intervention of mainte-
nance.
3.2 BASIC
Access control panel functions using the four panel buttons located directly underneath the LED Display
(g.4).
Fig.4- Functions of the buttons
MENU
1 CONNECT
ð
DMX Address
ð
Value (001-512)
DMX Mode
ð
Theater ð
1 Ch
ð
Amber Shift on Default: 001
Color Temperature:
2800K
3200K
3500K
4000K
4500K
5000K
5600K
6000K
6500K
Hue
<-025-025>
White Calibration:
Red <000-255>
Green <000-255>
Blue <000-255>
White <000-255>
2 Ch
ð
Amber Shift on
Color Temperature:
2800K
3200K
3500K
4000K
4500K
5000K
5600K
6000K
6500K
Hue
<-025-025>
White Calibration:
Red <000-255>
Green <000-255>
Blue <000-255>
White <000-255>
4Ch1
5Ch
6Ch1
10Ch1
15Ch1
17Ch1
Tour
ð
4Ch2
6Ch2
10Ch2
15Ch2
2 SETUP
ð
Screen
ð
Back Light
ð
On
10S
20S
30S
Flip Display
ð
NO-Yes
Key Lock
ð
NO-Yes
3 ADVANCED
ð
Full On Mode
ð
HB
Studio
Dimmer
Mode
ð
O
Dimmer 1
Dimmer 2
Dimmer 3
8
ECPARFC
3.3 MENU STRUCTURE
White Balance
ð
O
Manual:
Red <125-255>
Green <125-255>
Blue <125-255>
White <125-255>
Led Frequency
ð
600Hz
1200 Hz
2000 Hz
4000 Hz
6000Hz
25kHZ
Fan Mode
ð
Auto
On
O
Silent
Factory Reload
ð
NO-Yes
4 INFORMATION
ð
Fixture Hours
ð
0-9999
Version
ð
V1.0
UID
ð
15D00228****
5 STANDALONE
ð
Master/Slave
ð
Master/Slave
Eects
ð
Eect 1 <001-100>
Eect 2 <001-100>
Eect 3 <001-100>
Eect 4 <001-100>
Eect 5 <001-100>
Speed 1~100
Static
ð
Fixed color:
R
G
B
W
RG
RB
RW
GB
GW
BW
RGB
RGW
RBW
GBW
RGBW
Dimmer <000-255>
Color Temperature:
2800K
3200K
3500K
4000K
4500K
5000K
5600K
6000K
6500K
Dimmer <000-255>
Hue <-025-025>
Manual Color Mixer:
Red <000-255>
Green <000-255>
Blue <000-255>
White <000-255>
9
ECLPARFC
Number DMX
channels
Address of
start (example)
DMX address
occupied
Next possible start address
for unit No. 1
Next possible start address
for unit No. 2
Next possible start address
for unit No. 3
1 33 33 34 35 36
2 33 33-34 35 37 39
4 33 33 - 36 37 41 45
5 33 33 - 37 38 43 48
6 33 33 - 38 39 45 51
10 33 33 - 42 43 53 63
15 33 33 - 47 48 63 78
17 33 33 - 49 50 67 84
10
ECPARFC
3.4 DMX MODE
Press the button MENU so many times until the display shows DMX ADDRESS, and press the button ENTER
to conrm.
Press UP/DOWN button to select the desired value (001-512). Press and hold to scroll quickly.
Press ENTER button to store.
Press the MENU button to go back or to meet the waiting time to exit the setup menu.
To able to operate the ECLPARFC with a light controller, adjust the DMX start address for the rst a DMX
channel. If e. g. address 33 on the controller is provided for controlling the function of the rst DMX
channel, adjust the start address 33 on the ECLPARFC. The other functions of the light eect panel are
then automatically assigned to the following addresses.
An example with the start address 33 is shown below:
. . . . . . . . . . . .
DMX Address: 33 DMX Address: 48DMX Address: 38 DMX Address: 43
Fig.5 - Example 5 DMX channels conguration
. . . . . . . . . . . .
DMX512 Controller
3.5 DMX CONFIGURATION
ECLPARFC is equipped with dierent DMX conguration.
Press the button MENU so many times until shows DMX CHANNEL, and press the button ENTER to conrm.
Select the desired DMX conguration (THEATRE 1 / 2 / 4 / 5 / 6 / 10 / 15 / 17 ch - TOUR 4 / 6 / 10 / 15 channel) through
the buttons UP/DOWN.
The tables on pages 11, 12, 13, 14, 15, 16 and 17 indicate the operating modes and relative DMX values.
THEATRE 1 CHANNEL
MODE
FUNCTION DMX
Value
1 Ch
1
DIMMER
0~100% 000 - 255
THEATRE4 CHANNELS 1
MODE
FUNCTION DMX
Value
4 Ch 1
1
DIMMER
0~100% 000 - 255
2
CTO
2800K -3200K
3200K-3500 K
3500K-4000K
4000K-4500K
4500K-5000K
5000K-5600K
5600K-6000K
6000K-6500K
000 - 031
032 - 063
064 - 095
096 - 127
128 - 159
160 - 191
192 - 223
224 - 255
3
HUE
0
-25~25
000 - 000
001 - 255
4
DIMMER SPEED MODE
Preset dimmer speed from display menu
Dimmer speed mode o
Dimmer speed mode1 (fast speed)
Dimmer speed mode2 (middle speed)
Dimmer speed mode3 (slow speed)
000 - 051
052 - 101
102 - 152
153 - 203
204 - 255
THEATRE5 CHANNELS
MODE
FUNCTION DMX
Value
5 Ch
1
DIMMER
0~100% 000 - 255
2
CTO
2800K -3200K
3200K-3500 K
3500K-4000K
4000K-4500K
4500K-5000K
5000K-5600K
5600K-6000K
6000K-6500K
000 - 031
032 - 063
064 - 095
096 - 127
128 - 159
160 - 191
192 - 223
224 - 255
3
HUE
0
-25~25
000 - 000
001 - 255
4
STROBE
NO Function
Strobe Slow to Fast
000 - 010
011 - 255
5
DIMMER SPEED MODE
Preset dimmer speed from display menu
Dimmer speed mode o
Dimmer speed mode1 (fast speed)
Dimmer speed mode2 (middle speed)
Dimmer speed mode3 (slow speed)
000 - 051
052 - 101
102 - 152
153 - 203
204 - 255
THEATRE 2 CHANNELS
MODE
FUNCTION DMX
Value
2 Ch
1
DIMMER
0~100% 000 - 255
2
DIMMER SPEED MODE
Preset dimmer speed from display menu
Dimmer speed mode o
Dimmer speed mode1 (fast speed)
Dimmer speed mode2 (middle speed)
Dimmer speed mode3 (slow speed)
000 - 051
052 - 101
102 - 152
153 - 203
204 - 255
11
ECLPARFC
3.6 CHANNELS DMX
THEATRE 6 CHANNELS
MODE
FUNCTION DMX
Value
6 Ch 1
1
DIMMER
0~100% 000 - 255
2
CTO
2800K -3200K
3200K-3500 K
3500K-4000K
4000K-4500K
4500K-5000K
5000K-5600K
5600K-6000K
6000K-6500K
000 - 031
032 - 063
064 - 095
096 - 127
128 - 159
160 - 191
192 - 223
224 - 255
3
HUE
0
-25~25
000 - 000
001 - 255
4
STROBE
NO Function
Strobe Slow to Fast
000 - 010
011 - 255
5
COLOR MACRO
No Function
Amber Shift on
Color Macro
000 - 002
003 - 005
006 - 255
6
DIMMER SPEED MODE
Preset dimmer speed from display menu
Dimmer speed mode o
Dimmer speed mode1 (fast speed)
Dimmer speed mode2 (middle speed)
Dimmer speed mode3 (slow speed)
000 - 051
052 - 101
102 - 152
153 - 203
204 - 255
THEATRE 10 CHANNELS 1
MODE
FUNCTION DMX
Value
10 Ch 1
1
DIMMER
0~100% 000 - 255
2
RED
0~100% 000 - 255
3
GREEN
0~100% 000 - 255
4
BLUE
0~100% 000 - 255
5
WHITE
0~100% 000 - 255
6
CTO
2800K-3200K
3200K-3500K
3500K-4000K
4000K-4500K
4500K-5000K
5000K-5600K
5600K-6000K
6000K-6500K
No Function
000 - 030
031 - 060
061 - 090
091 - 120
121 - 150
151 - 180
181 - 210
211 - 240
241 - 255
7
HUE
0
-25~25
000 - 000
001 - 255
8
STROBE
NO Function
Strobe Slow to Fast
000 - 010
011 - 255
9
COLOR MACRO
No Function
Amber Shift on
Color Macro
000 - 002
003 - 005
006 - 255
10
DIMMER SPEED MODE
Preset dimmer speed from display menu
Dimmer speed mode o
Dimmer speed mode1 (fast speed)
Dimmer speed mode2 (middle speed)
Dimmer speed mode3 (slow speed)
000 - 051
052 - 101
102 - 152
153 - 203
204 - 255
12
ECPARFC
THEATRE 15 CHANNELS 1
MODE
FUNCTION DMX
Value
15 Ch 1
1
DIMMER
0~100% 000 - 255
2
DIMMER FINE
0~100% 000 - 255
3
RED
0~100% 000 - 255
4
RED FINE
0~100% 000 - 255
5
GREEN
0~100% 000 - 255
6
GREEN FINE
0~100% 000 - 255
7
BLUE
0~100% 000 - 255
8
BLUE FINE
0~100% 000 - 255
9
WHITE
0~100% 000 - 255
10
WHITE FINE
0~100% 000 - 255
11
CTO
2800K-3200K
3200K-3500K
3500K-4000K
4000K-4500K
4500K-5000K
5000K-5600K
5600K-6000K
6000K-6500K
No Function
000 - 030
031 - 060
061 - 090
091 - 120
121 - 150
151 - 180
181 - 210
211 - 240
241 - 255
12
HUE
0
-25~25
000 - 000
001 - 255
13
STROBE
NO Function
Strobe Slow to Fast
000 - 010
011 - 255
14
COLOR MACRO
No Function
Amber Shift on
Color Macro
000 - 002
003 - 005
006 - 255
15
DIMMER SPEED MODE
Preset dimmer speed from display menu
Dimmer speed mode o
Dimmer speed mode1 (fast speed)
Dimmer speed mode2 (middle speed)
Dimmer speed mode3 (slow speed)
000 - 051
052 - 101
102 - 152
153 - 203
204 - 255
THEATRE 17 CHANNELS
MODE
FUNCTION DMX
Value
17 Ch 1
1
DIMMER
0~100% 000 - 255
2
DIMMER FINE
0~100% 000 - 255
3
STROBE
No Function (shutter open)
Strobe eect slow to fast
No Function (shutter open)
Random strobe eect slow to fast
No Function (shutter open)
000 - 030
031 - 100
101 - 130
131 - 200
201 - 255
4
CTO
2800K-3200K
3200K-3500K
3500K-4000K
4000K-4500K
4500K-5000K
5000K-5600K
5600K-6000K
6000K-6500K
000-031
032-063
064-095
096-127
128-159
160-191
192-223
224-255
5
HUE
0
-25~25
000 - 000
001 - 255
6
CROSSFADE
0~100% 000 - 255
7
RED
0~100% 000 - 255
8
RED FINE
0~100% 000 - 255
9
GREEN
0~100% 000 - 255
10
GREEN FINE
0~100% 000 - 255
11
BLUE
0~100% 000 - 255
12
BLUE FINE
0~100% 000 - 255
13
WHITE
0~100% 000 - 255
14
WHITE FINE
0~100% 000 - 255
15
COLOR MACRO
No Function
Amber Shift on
Color Macro
000 - 002
003 - 005
006 - 255
16
CTO ON COLORS
0~100% 000 - 255
17
DIMMER SPEED MODE
Preset dimmer speed from display menu
Dimmer speed mode o
Dimmer speed mode1 (fast speed)
Dimmer speed mode2 (middle speed)
Dimmer speed mode3 (slow speed)
000 - 051
052 - 101
102 - 152
153 - 203
204 - 255
13
ECLPARFC
TOUR 10 CHANNELS
MODE
FUNCTION DMX
Value
10 Ch 2
1
DIMMER
0~100% 000 - 255
2
RED
0~100% 000 - 255
3
GREEN
0~100% 000 - 255
4
BLUE
0~100% 000 - 255
5
WHITE
0~100% 000 - 255
6
STROBE
NO Function
Strobe Slow to Fast
000 - 010
011 - 255
7
COLOR TEMPERATURE
No Function
2800K
3200K
3500K
4000K
4500K
5000K
5600K
6000K
6500K
No Function
000 - 005
006 - 030
031 - 055
056 - 080
081 - 105
106 - 130
131 - 155
156 - 180
181 - 205
206 - 230
231 - 255
8
AUTO PROGRAMS
No Function
Auto Program 1
Auto Program 2
Auto Program 3
Auto Program 4
Auto Program 5 (Auto Program1-4)
000 - 010
011 - 060
061 - 110
111 - 160
161 - 210
211 - 255
9
AUTO SPEED
Auto speed slow to fast 000 - 255
10
DIMMER SPEED MODE
Preset dimmer speed from display menu
Dimmer speed mode o
Dimmer speed mode1 (fast speed)
Dimmer speed mode2 (middle speed)
Dimmer speed mode3 (slow speed)
000 - 051
052 - 101
102 - 152
153 - 203
204 - 255
TOUR 6 CHANNELS 2
MODE
FUNCTION DMX
Value
6 Ch 2
1
DIMMER
0~100% 000 - 255
2
RED
0~100% 000 - 255
3
GREEN
0~100% 000 - 255
4
BLUE
0~100% 000 - 255
5
WHITE
0~100% 000 - 255
6
STROBE
NO Function
Strobe Slow to Fast
000 - 010
011 - 255
TOUR 4 CHANNELS 2
MODE
FUNCTION DMX
Value
4 Ch 2
1
RED
0~100% 000 - 255
2
GREEN
0~100% 000 - 255
3
BLUE
0~100% 000 - 255
4
WHITE
0~100% 000 - 255
14
ECPARFC
TOUR 15 CHANNELS 2
MODE
FUNCTION DMX
Value
15 Ch 2
1
DIMMER
0~100% 000 - 255
2
DIMMER FINE
0~100% 000 - 255
3
RED
0~100% 000 - 255
4
RED FINE
0~100% 000 - 255
5
GREEN
0~100% 000 - 255
6
GREEN FINE
0~100% 000 - 255
7
BLUE
0~100% 000 - 255
8
BLUE FINE
0~100% 000 - 255
9
WHITE
0~100% 000 - 255
10
WHITE FINE
0~100% 000 - 255
11
STROBE
NO Function
Strobe Slow to Fast
000 - 010
011 - 255
12
COLOR TEMPERATURE
No Function
2800K
3200K
3500K
4000K
4500K
5000K
5600K
6000K
6500K
No Function
000 - 005
006 - 030
031 - 055
056 - 080
081 - 105
106 - 130
131 - 155
156 - 180
181 - 205
206 - 230
231 - 255
13
AUTO PROGRAMS
No Function
Auto Program 1
Auto Program 2
Auto Program 3
Auto Program 4
Auto Program 5 (Auto Program1-4)
000 - 010
011 - 060
061 - 110
111 - 160
161 - 210
211 - 255
14
AUTO SPEED
Auto speed slow to fast 000 - 255
15
DIMMER SPEED MODE
Preset dimmer speed from display menu
Dimmer speed mode o
Dimmer speed mode1 (fast speed)
Dimmer speed mode2 (middle speed)
Dimmer speed mode3 (slow speed)
000 - 051
052 - 101
102 - 152
153 - 203
204 - 255
15
ECLPARFC
16
ECPARFC
3.7 SCREEN
You can change the following parameters related to the display, following the same procedure:
Press the MENU button to access the main menu.
Press the UP / DOWN keys to scroll the menu, select Set Up, then press the ENTER button to enter the
next menu.
Press UP / DOWN to scroll through the menu, then select Screen, and press the ENTER button to enter
the next menu.
Press UP / DOWN to scroll through the menu, and then select one of the following settings for the dis-
play and press the ENTER key to display it.
- Back Light - Backlight display Auto O. This feature allows you to automatically turn o the backlight
after a specied time that you can set using the arrow buttons. To have the display always on select
On or choose another value to turn o the display after the amount of time you choose.
- Flip Display - Orientation of the display. This function allows you to rotate the display 180° to get a
better view of the display when the unit is hanging upside down. Select YES to activate or NO to dis-
able this function.
- Key Lock - With this function, you can lock the buttons on the control panel. If this functionis activat-
ed, the keys are automatically locked. To disable or temporarily disable the key lock function, press
the buttons in the following order to regain access to menu commands: UP, DOWN, UP, DOWN,
ENTER. Select ON to activate or OFF to disable
Press the ENTER button to conrm your choice.
Press the MENU button repeatedly to exit the menu and save changes.ù
3. 8 FIXTURE SETTINGS
It is possible to change the parameter value in the following way:
DIMMER
Enter in Dimmer mode to select specic dimming curve, press the button MENU so many times until
shows DIM MODE, and press the button ENTER to conrm.
Press the button UP/DOWN to select OFF - DIM1 - DIM2 - DIM3.
Press ENTER button to store.
Press the MENU button to go back or to meet the waiting time to exit the setup menu.
LED FREQUENCY
To adjust the frequency of the LEDs, press the MENU button repeatedly until the display shows LED
Frequency, and then press the ENTER button.
Select the frequency (600Hz - 1200Hz - 2000Hz - 4000Hz - 6000Hz - 25kHz) using the UP/DOWN buttons.
To conrm, press the ENTER key.
Press the MENU button to go back or wait a few seconds to exit the setup menu.
FAN MODE
Select this function to set the fans operation mode. Use the arrow buttons to select Auto, On, O, Silent.
Press the ENTER button to conrm your choice
FACTORY RELOAD
Select this function to reset the unit to the factory settings:
- To activate Reset Factory display press the button MENU so many times until shows Factory Reload, and
press the button ENTER to conrm.
Press ENTER button to conrm the selection.
Press the MENU button to go back or to meet the waiting time to exit from the setup menu automati-
cally.
17
ECLPARFC
3. 9 FIXTURE INFORMATION
To view all the information on the device, proceed as follows:
Press the MENU button to access the main menu.
Press the UP/DOWN button to scroll the menu, select the icon Information, then press the ENTER but-
ton to enter the next menu.
Press the UP/DOWN button to scroll through the menu, then select one of the following information
and press the ENTER button to display it.
- Fixture Hours - Through the Fixture Time function you can display the operating time of the projector.
- Software Version - Through Version function you can display the currently installed software version.
- UID - This option shows the RDM identication number
Press the MENU button repeatedly to exit the menu.
3. 10 OPERATIONS IN AUTOMATIC MODE
MASTER SLAVE
Press the UP/DOWN button to scroll through the menu, select Master/Slave and press ENTER to conrm
your choice.
Press the UP/DOWN button to select the mode of operation:
- Master, if the unit is connected in series with other units and it acts as the Master;
- Slave, if the unit is not connected to other units.
Press the ENTER button to conrm your choice.
EFFECTS
The unit independently runs through its show. Before you send an automatic program you need to set the
drive as Master/Alone:
Press the MENU button to access the main menu.
Press the UP/DOWN button to scroll the menu, select the Eects icon, then press the ENTER button to
enter the next menu.
Press the UP/DOWN button to select the mode of operation: Eects 1, Eects 2, Eects 3
Press the ENTER button to conrm your choice.
Press the MENU button repeatedly to exit the menu and save changes.
The unit will go into automatic mode by executing the program automatically.
STATIC MODE
This xture has the ability to accept custom static color settings. Access these chases via the control panel
on the back of the xture.
Press the button MENU so many times until the display shows Static, then press the button ENTER.
Select Fixed Color through the buttons UP/DOWN, then press the button ENTER.
Set the colors R, G, B, W, RG, RB, RW, GB, GW, BW RGB, RGW, RBW, GBW, RGBW, through the buttons UP/DOWN,
then press the button ENTER.
Press the MENU button to go back or to meet the waiting time to exit the setup menu.
NOTE: If the projector is in Blackout mode before synchronizing with the DMX signal, and if the DMX signal
is lost, the projector will remain on according to the last received DMX value.
If the projector was in STATIC or AUTO mode before synchronizing with the DMX signal, if the DMX signal
is lost, the projector will return to the previously set STATIC or AUTO.
18
ECPARFC
- 4 - MAINTENANCE
4.1 MAINTENANCE AND CLEANING THE UNIT
Make sure the area below the installation place is free from unwanted persons during setup.
Switch o the unit, unplug the main cable and wait until the unit has cooled down.
All screws used for installing the device and any of its parts should be tightly fastened and should not
be corroded.
Housings, xations and installation spots (ceiling, trusses, suspensions) should be totally free from any
deformation.
The main cables must be in impeccable condition and should be replaced immediately even when a
small problem is detected.
It is recommended to clean the front at regular intervals, from impurities caused by dust, smoke, or
other particles to ensure that the light is radiated at maximum brightness. For cleaning, disconnect the
main plug from the socket. Use a soft, clean cloth moistened with a mild detergent. Then carefully wipe
the part dry. For cleaning other housing parts use only a soft, clean cloth. Never use a liquid, it might
penetrate the unit and cause damage to it.
4.2 FUSE REPLACEMENT
1. Remove the safety cap by a screwdriver.
2. Replace the blown fuse with a fuse of the exact same type and rating.
3. Install the safety cap, and reconnect power.
4.3 TROUBLESHOOTING
Problems Possible causes Checks and remedies
Fixture does not light up
No mains supply
Dimmer fader set to 0
Faulty LED
Check the power supply voltage
Increase the value of the dimmer channels
Replace the LED board
General low light intensity
Dirty lens assembly
Misaligned lens assembly
Clean the xture regularly
Install lens assembly properly
Fixture does not power up
No power
Loose or damaged power cord
Check for power on power outlet
Check power cord
Contact an authorized service center in case of technical problems or not reported in the table can not be
resolved by the procedure given in the table.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

ProLights ECLPARFC Manuale utente

Categoria
Stroboscopi
Tipo
Manuale utente

in altre lingue