CAME 803XC-0020 Guida d'installazione

Tipo
Guida d'installazione
FA01919M4A - 02/2023
FA01919M4A
803XC-
0020
02/2023
IT Italiano
EN English
FR Français
RU Pусский
CAME S.p.A.
Via Martiri Della Libertà, 15
31030 - Dosson di Casier
Treviso - Italy
A
A B GND
10 11
AC
AC
GND
B
A
ETH PORT
abc
RSE
ZLB30B
ZL392B
ZL392C
a
b
c
d
e
de
LAN
Ethernet cable
B
RSE2
Modbus register maƉĨŽƌĂƵƚŽŵĂƟŽŶ
Interface seƫngs Protocol Baud Parity Data bits Stop bits
Modbus RTU 38400 Even 8 1
Register name DescripƟon Register type R/W Modbus
address
Device informaƟons
Board ID Most signiĮcant byte: CRP board class
Less signiĮcant byte: CRP board ID
Unsigned short R 40001
FW version Firmware version: V1.V2.V3
V1 = Įƌst word, V2 = second word, V3 = third word
Unsigned short x 3 R 40002
40003
40004
Serialnumber Device serial number
String of ASCII characters
Char x 14 R 40005
40006
40007
40008
40009
40010
40011
AutomaƟon status
Gate status 0=Unknown 3=CalibraƟng 17=Closed
16=Open 18=ParƟalopen 19=Stoppe
32=Opening 33=Closing 34 ParƟal opening
Unsigned short R 40101
Gate posiƟŽn 255=Unknown Opening posiƟon from 0% to 100% Unsigned short R 40102
Status Ňags AutomaƟon status Ňags: the read valueis a bit mask where eachbit means
aspeciĮcstatus. For the bit descripƟon see the status Ňags alias secƟon .
Unsigned short R 40103
Last error Last occurred errorcode Unsigned short R 40104
OperaƟŽn counter Total executed open and close operaƟŽns Unsigned long
(LSW Įƌst)
R 40105
40106
ParƟal counter ParƟaloperaƟŽns counter (executed from the last operaƟŽnreset) Unsigned long
(LSW Įƌst)
R 40107
40108
Inputs status Inputs status: the read value is a bit mask where each bitreports the status
of a speciĮc input. For the bit descripƟŽn see the input status secƟŽn.
Unsigned short R 40109
Board temperature Measured board temperature (°C) Signed short R 40110
Commands
Stop Command STOP Discrete output W 1
Open Command OPEN Discreteoutput W 2
ParƟal open Command PARTIAL OPEN Discreteoutput W 3
Close Command CLOSE Discrete output W 4
Step Commnad STEP Discrete output W 5
SequenƟal Command SEQUENTIAL Discrete output W 6
Reset Board reset Discrete output W 8
Status Ňags alias (is thesame of the “Status Ňags” register – 40103)
Status Ňag bit 0: Need calibraƟon Discreteinput R 10103
Status Ňag bit 1: FA input acƟve Discreteinput R 10104
Status Ňag bit 2: FC input acƟve Discrete input R 10105
Status Ňag bit 3: Door open Discrete input R 10106
Status Ňag bit 4: Motor unblocked Discrete input R 10107
Status Ňag bit 5: Doom fallen Discrete input R 10108
Status Ňag bit 6: Obstacle while opening Discreteinput R 10109
Status Ňag bit 7: Obstacle while closing Discreteinput R 10110
Status Ňag bit 8: ExecuƟng Discreteinput R 10111
Status Ňag bit 9: Is opening Discrete input R 10112
Status Ňag bit 10: Is closing Discrete input R 10113
Status Ňag bit 11: Need maintenance Discrete input R 101 14
Inputs status alias (is the same of the “Input status” register – 40109)
Input status bit 0: input 2-3 10119
Input status bit 1: input 2-3P 10120
Input status bit 2: input 2-4 10121
Input status bit 3: input 2-7 10122
Input status bit 4: input FA 10123
Input status bit 5: input FC 10124
Input status bit 6: - 10125
Input status bit 7: - 10126
Input status bit 8: input 2-1 10127
Input status bit 9: input Cx 10128
Input status bit 10: input Cy 10129
Input status bit 11: input Cz 10130
Modbus RTU
A B GND A B GND R G B
2
24
10
S1 GND
AB
11 E1 E6 TS 1 2 3 3P 4 5 7 2 CX CY CZ 0300
FA FC TAMP ER
FCA CM1 FCC CM2 EB
MOTOR
BLOCK ARM
EB
+
C
803XC-0020
FA01919M4A - 02/2023
ITALIANO
Avvertenze generali per l'installatore
Il prodotto deve essere destinato solo all’uso per il quale
è stato espressamente studiato e ogni altro uso è da
considerarsi pericoloso. • Tutte le operazioni indicate in
questo manuale devono essere effettuate esclusivamente
da personale esperto e qualificato e nel pieno rispetto delle
normative vigenti. • Durante tutte le fasi dell’installazione
assicurarsi di operare fuori tensione.
Descrizione
Bridge Modbus TCP/RTU per l'integrazione con sistemi di
terze parti.
Descrizione delle parti
1 Bridge Modbus TCP/RTU
2 Cavo di collegamento
3 Scheda RSE (*)
(*) Accessorio non fornito.
Collegamenti elettrici B
aCavo bianco
bCavo marrone
cCavo nero
dCavo verde
eCavo grigio
Configurazione C
Dal browser, accedere all'indirizzo IP del dispositivo.
Consultare la tabella IMPOSTAZIONI DIP SWITCH nelle
istruzioni fornite con il dispositivo.
Posizionare i DIP SWITCH secondo la configurazione desiderata.
Riavviare il dispositivo.
Assicurarsi che la funzione [RSE2] sia impostata su
[Modbus RTU] sul quadro comando dell'automazione.
Scaricare il modulo ModBus register map dal sito www.docs.
came.com per la mappa dei registri.
Dismissione e smaltimento
Non disperdere nell’ambiente l’imballaggio e il dispositivo alla
fine del ciclo di vita, ma smaltirli seguendo le norme vigenti nel
paese di utilizzo del prodotto. I componenti riciclabili riportano
simbolo e sigla del materiale.
I DATI E LE INFORMAZIONI INDICATE IN QUESTO MANUALE
SONO DA RITENERSI SUSCETTIBILI DI MODIFICA IN QUALSIASI
MOMENTO E SENZA OBBLIGO DI PREAVVISO.
LE MISURE, SE NON DIVERSAMENTE INDICATO, SONO IN
MILLIMETRI.
ENGLISH
General precautions for installers
Only use this product for its intended purpose. Any other use
is hazardous. • All operations indicated in this manual must
be carried out exclusively by skilled and qualified personnel
and in full compliance with the regulations in force. • Make
sure the mains power supply is disconnected during all
installation procedures.
Description
TCP/RTU Modbus bridge for integration with third-party
systems.
Description of parts
1 TCP/RTU Modbus bridge
2 Connection cable
3 RSE card (*)
(*) Accessory not supplied.
Electrical connections B
aWhite cable
bBrown cable
cBlack cable
dGreen cable
eGrey cable
Configuration C
From the browser, access the IP address of the device.
Refer to the DIP SWITCH SETTINGS table in the
instructions supplied with the device.
Position the DIP SWITCHES according to the desired
configuration.
Restart the device.
Make sure that the [RSE2] function is set to [Modbus
RTU] on the operator’s control panel.
Download the ModBus register map form from www.docs.
came.com for the register map.
Dismantling and disposal
Dispose of the packaging and the device responsibly at the
end of its life cycle, in compliance with the laws in force
in the country where the product is used. The recyclable
components are marked with the material symbol and ID.
THE DATA AND INFORMATION IN THIS MANUAL MAY BE
CHANGED AT ANY TIME AND WITHOUT NOTICE.
MEASUREMENTS ARE IN MILLIMETRES, UNLESS STATED
OTHERWISE.
FRANÇAIS
Instructions générales pour l’installateur
Ce produit ne devra être destiné qu'à l'utilisation pour laquelle
il a été expressément conçu et toute autre utilisation est
à considérer comme dangereuse. • Toutes les opérations
indiquées dans ce manuel ne doivent être exécutées que par
du personnel qualifié et dans le plein respect des normes en
vigueur. • S’assurer, durant toutes les phases d’installation,
que l’automatisme est bien hors tension.
Description
Bridge Modbus TCP/RTU pour l'intégration avec les systèmes
tiers.
Description des parties
1
Modbus Bridge TCP/RTU
2
Câble de connexion
3
Carte RSE (*)
(*) Accessoire non fourni.
Branchements électriques
B
a
Câble blanc
b
Câble marron
c
Câble noir
d
Câble vert
e
Câble gris
Configuration
C
Depuis le navigateur, accéder à l'adresse IP du dispositif.
Consulter le tableau CONFIGURATIONS DES MICRO-
INTERRUPTEURS DIP dans les instructions fournies avec le
dispositif.
Positionner les micro-interrupteurs DIP selon la configuration
souhaitée.
Remettre le dispositif en marche.
S’assurer que la fonction [RSE2] est bien réglée sur
[Modbus RTU] sur l’armoire de commande de l'automatisme.
Télécharger le module ModBus register map sur www.docs.
came.com pour la liste des registres.
Mise au rebut et élimination
Ne pas jeter l'emballage et le dispositif dans la nature au terme
du cycle de vie de ce dernier, mais les éliminer selon les normes
en vigueur dans le pays où le produit est utilisé. Le symbole et
le sigle du matériau figurent sur les composants recyclables.
LE CONTENU DE CE MANUEL EST SUSCEPTIBLE DE SUBIR DES
MODIFICATIONS À TOUT MOMENT ET SANS AUCUN PRÉAVIS.
LES DIMENSIONS SONT EXPRIMÉES EN MILLIMÈTRES, SAUF
INDICATION CONTRAIRE.
РУССКИЙ
Общие предупреждения для монтажника
Это изделие должно использоваться исключительно по
назначению. Использование не по назначению считается
опасным. • Все описанные в этом руководстве операции
должны выполняться исключительно квалифицированным
и опытным персоналом и в полном соответствии с
действующим законодательством. • Убедитесь в отсутствии
напряжения перед каждым этапом монтажных работ.
Описание
Шлюз Modbus TCP/RTU для связи с системами сторонних
производителей.
Описание компонентов
1
Шлюз Modbus TCP/RTU
2
Кабель электропитания
3
Плата RSE (*)
(*) Аксессуар не входит в комплект поставки.
Электрические подключения
B
a
Белый провод
b
Коричневый провод
c
Черный кабель
d
Зеленый кабель
e
Серый провод
Настройка
C
В браузере зайдите на IP-адрес устройства.
Сверьтесь с таблицей НАСТРОЙКИ DIP-
ПЕРЕКЛЮЧАТЕЛЕЙ в инструкции, поставляемой вместе с
устройством.
Расположите DIP-ПЕРЕКЛЮЧАТЕЛИ в соответствии с
желаемой конфигурацией.
Перезагрузите устройство.
Удостоверьтесь, что функция [RSE2] настроена на
[Modbus RTU] в блоке управления автоматики.
Скачайте модуль ModBus register map на сайте www.docs.
came.com для карты регистров.
Утилизация
Не выбрасывайте упаковку и устройство совместно с бытовыми
отходами. Утилизируйте их в соответствии с требованиями
законодательства, действующего в стране установки изделия.
Пригодные для повторного использования компоненты
отмечены специальным символом с обозначением материала.
СОДЕРЖАНИЕ ЭТОГО РУКОВОДСТВА МОЖЕТ БЫТЬ ИЗМЕНЕНО
В ЛЮБОЕ ВРЕМЯ БЕЗ ПРЕДВАРИТЕЛЬНОГО УВЕДОМЛЕНИЯ.
ВСЕ РАЗМЕРЫ ПРИВЕДЕНЫ В МИЛЛИМЕТРАХ, ЕСЛИ НЕ
УКАЗАНО ИНОЕ.
  • Page 1 1
  • Page 2 2

CAME 803XC-0020 Guida d'installazione

Tipo
Guida d'installazione

in altre lingue