Installation Instructions
& User Guide
Please leave these instructions
with the end user
Pack Contents
To replace any spare parts
for your tap, why not
scan the QR Code or
visit www.bristan.com
and search for your
product.
Specifications
Dynamic Water Pressure
Maximum Static Pressure: 10.0 bar
Max: 5.0 bar
Adjustable Spanner
0
1.0
2.0
5.0
4.0
3.0
Pressure
BAR
Inlet Water Temperature Inlet Connections
Spare Parts
Prior to Installation
Operation
1/2” BSP
Flexible Tails
60°C
Maximum Hot 60°C
Min: 0.5 bar
GLD2 ES BAS C (D1)
Tools Required for Installation/ Maintenance
All products manufactured and supplied by Bristan are safe to use provided that they are installed, operated and
receive regular maintenance in accordance with these instructions.
This product needs to be installed in accordance with, and meet the requirements of The Water Supply (Water
Fittings) Regulations (Northern Ireland) 2009 and The Water Supply (Water Fittings) (Scotland) Byelaws 2014.
For full Installation Requirements & Notes (IRN) please visit www.wrasapprovals.co.uk/approvals-directory
Isolation valves must be fitted to the inlet water supplies to ensure ease of future maintenance.
Before installing this product the water supply must be thoroughly flushed in order to remove any swarf, solder etc.
Full access must be made available for future maintenance/servicing purposes.
This product must not be modified in any way as this will invalidate the guarantee.
Hexagonal Keys Flat Head
Screwdriver
Box Spanner
(cartridge)
On
Fixing Kit
(2 Rod)
Glide 2 Tap
Clicker Waste
Upper Washer
Lower Washer
Backnut
Plinth
Plinth Seal
x1
x1
x1
x1
x1
x1
x1
x1
3.5mm
2.5mm 27mm
Box Spanner
(fixing rod nut)
7.5mm
Hot
For cold water, position the handle
straight forward so it is parallel with
the spout (the handle will stop here
when pushing it to the right)
To increase temperature, turn the
handle to the left
The temperature will gradually
rise the further the rotation of the
handle
The handle will cease to turn once
it is at a 90° angle, supplying the
maximum temperature
Temperature Control
Features
Eco Start
x1
Flexible Tails
(pair)
Installation
2 2*
1
3
Look underneath the tap
body to observe fixing
kit rod(s) and tail inlet
positions
Depending on the model, the tap will utilise 1 or 2
fixing kit rods. Refer to contents page
Screw in the fixing
kit rod(s) into the
base of the tap
Screw in the
flexible tails by
hand only.
DO NOT
OVERTIGHTEN
If required, thread
the flexible tails
and fixing kit rods
through the plinth
and rubber seal
(if loose) and align
with tap body
Thread the flexible
tails and fixing kit
rods through the
basin hole
If the hole is not
large enough for
both tail ends to
fit through,
unscrew one of
the flexible tails
and screw back in
from underneath
the basin
4
From underneath
the basin, slide the
fixing rod(s) through
the rubber gasket
first and then the
metal c plate
You can screw
the nut by hand
and tighten with
a box spanner
once at the top
1 Fixing Rod 2 Fixing Rods
Fixing
Rod Hole
Flexi Tails
Holes
Flexi Tails
Holes
Fixing
Rod Hole
Fixing
Rod Hole
Important
The images shown are for
illustrative purposes only.
The tap you have purchased may
look dierent to those pictured in
this booklet but will follow the same
installation steps.
Your contents page will be specific
to your product.
If you find your product or any of
its components dier from those
shown on the contents page, please
contact our customer support.
Align the gasket and
c plate, then begin
tightening the nut up
the rod towards the
basin until secure
Your model may
come with a plinth
and will
either be included
pre-attached or
loose in the box*
Look for any grub screw
holes on the plinth as
these may be required to
fix it to the tap body
(these can be located
underneath the
rubber seal)
Connect the hot
and cold water
supplies to the
flexible tails and
turn until tight
Hot on the
left, cold on
the right
5
Your tap is now
ready for use.
IMPORTANT
Turn on water
supply for a few
minutes and check
all joints and
connections for
any leaks.
1 2
3
Fit the waste above the basin
ensuring the washer is in place.
Push waste into
hole until the
outer rim sits
flush with the
bottom of
the basin
Push the centre down to close the waste
Bristan products are made from premium
materials, with hand polished, electroplated,
PVD or EPD finishes.
Your taps or shower should be regularly
cleaned with warm water, a mild pH-neutral
liquid soap, and polished with a soft cloth.
Any residues from soap, toothpaste,
shampoos and shower gels can cause
blemishes if not rinsed o straight after use.
Household bleaches and cleaners contain
harsh chemicals and may damage the surface
finish. Avoid using abrasive cloths, scouring
pads, scrub sponges, steel wool or anything
similar.
6
Then place the
washer from
underneath and
tighten the
backnut to secure
the waste to the
basin
Slight
bend
90 °
angle
Kinks
Curved
round Twists
REMEMBER
Refer to the
next panel for
correct flexible
tail positions
Waste Installation and Operation
Push again to open and
release contents of basin Your waste is now
ready for use.
General Cleaning
3
Bristan oers an eective
chrome-friendly cleaning kit
for use with your taps and
showers. Scan the QR Code or
search for ‘CLEAN KIT01’ on
www.bristan.com.
Reverse the steps to
replace the outlet
12
Remove indice by pulling it
loose, then undo hex grub
screw to remove handle
Remove
the shroud and
retaining nut and
then lift the
cartridge out of
the tap
(Some shrouds
may need to be
unscrewed by hand
before removing)
13
12
Reverse the steps to
replace the
cartridges/ valves
and handles.
2
1b
Observe the outlet
and use the
corresponding tool
(Models that have
narrow spouts may
not have removable
outlets)
Check all loose
parts for any
damage, then
soak using a
suitable solution
to de-scale
Recessed Outlet
Coin Slot Aerator
If your model
comes with one,
insert the key tool
into the outlet and
twist to release it
Using a coin, insert
into the slot on the
outlet and twist to
release it
Using an
adjustable
spanner, unscrew
gently to remove
the outlet
Flow Straightener
1a
1c
2
Maintenance - Cartridge/ Valve Replacement
Isolate the
water supply
before
starting!
IMPORTANT
Maintenance - Clean/ Replace Outlet
Using a box
spanner will
ensure that you
can reach the
retaining nut if it
recessed into
the tap body
Love Your Chrome
Symptom Cause Remedy
Low Flow
Partially closed isolation valve. Open isolation valve.
Airlock or partial blockage in the supply
pipework.
Flush through pipework to ensure removal of
debris and any airlocks.
Partial blockage in the outlet Remove to Clean and soak in suitable
solution.
No hot water or
cycling hot and
cold
Instantaneous water heater cycles on
and o as flow rate or pressure is too
low.
Increase water flow rate or pressure through
system.
No Flow Closed isolation valve. Open isolation valve.
Mains water supply turned o. Turn on mains water supply.
Temperatures not
corresponding
with taps
Inlet pipes have been connected
incorrectly
Swap the inlet tails around.
Troubleshooting
Notes
Please use this space for any notes you
or your installer may have regarding the
installation/plumbing of this product.
At Bristan, we want to make things as easy as possible for our customers. That’s why we oer
solid guarantees on all our products, eective from the date of purchase, to give you peace of mind.
Your guarantee starts from the purchase of your product, but you can still benefit from registering it for
easier identification in the unlikely event of a manufacturing fault, please visit www.bristan.com/register
For any other queries, please call Customer Service on 0330 026 6273 where our expert team
of advisors will be able to oer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/service-centre/guarantees.
Our Guarantee
Bristan Group Ltd.
UK: Bristan Group, B78 1SG.
EU: Masco Europe S.à.r.l.
14 Rue Strachen
6933 Mensdorf
Luxembourg
Customer Service: +44330 026 6273
Web: www.bristan.com
Email: enquire@bristan.com
A Masco Company
Contact Us
Servicing Your Tap
We recommend servicing your tap at
least once every year to prolong its life.
To see a video showing how to remove
the cartridge for servicing, scan the QR
code with your smart phone or tablet.
Alternatively visit www.youtube.com/
BristanTV