CONTENTS
____________________________________________________________
1
GENERAL INFORMATION
........................................................ 1
1.1 SCOPE OF THE MANUAL
............................................................................1
1.2 ENCLOSED DOCUMENTS
...........................................................................2
1.3 PACKAGE CONTENTS
................................................................................2
1.4 TERMINAL MANUFACTURER AND MODEL IDENTIFICATION
......................3
2
TECHNICAL INFORMATION
..................................................... 4
2.1 TERMINAL DESCRIPTION
...........................................................................4
2.2 TECHNICAL CHARACTERISTICS
................................................................5
3
SAFETY REGULATIONS
........................................................... 8
3.1 GENERAL SAFETY RULES
............................................................................8
3.2 MAINTENANCE SAFETY
............................................................................9
3.3 DANGER SIGNALS
.....................................................................................9
3.4 U.S. FEDERAL COMMUNICATIONS
COMMISSION RADIO FREQUENCY INTERFERENCE STATEMENT -
INFORMATION TO THE USER
....................................................................10
4
CONNECTIONS
...................................................................... 11
4.1 TERMINAL CONNECTION TO THE HOST COMPUTER
................................11
4.1.1 RS-232 Connection
....................................................................11
4.1.2 Other types of connection
...........................................................13
4.2 CRADLE F985
..........................................................................................16
4.2.1 F985 cradle
.................................................................................18
4.2.2 F985 vehicle cradle
......................................................................19
3.1 CONNECTION CABLES
.............................................................................20
5
USE AND FUNCTIONING
........................................................ 22
5.1 PCMCIA CARD
........................................................................................22
5.1.1 Inserting the PCMCIA card
..........................................................22
5.1.2 Extracting the PCMCIA card
........................................................24
5.2 TURNING ON THE TERMINAL
...................................................................25
CONTENTS
_____________________________________________________________
5.3 BAR CODE SCANNING
............................................................................. 26
5.4 DESCRIPTION OF THE KEYS
...................................................................... 27
6
MAINTENANCE AND DIAGNOSTICS
..................................... 35
6.1 CHARGING THE BATTERIES
...................................................................... 35
6.2 REPLACING THE BATTERIES
..................................................................... 36
6.3 CLEANING THE TERMINAL
....................................................................... 37
A
PRODUCTS AND ACCESSORIES
OF THE FORMULA 8500 LINE
................................................ 38
Ed.: 01/99
1
1
1.1 SCOPE OF THE MANUAL
This manual was compiled by Datalogic S.p.a. and accompanies the Formula 8500
terminal.
The information contained here is divided into two parts:
-
Chapters 1, 2, 3, 5:
which define the terminal’s characteristics and methods of use; these chapters
are for whomever uses the terminal in their day to day work activity.
-
Chapters 4, 5, 6:
which define the connections methods for the terminal. These chapters are
aimed at the person responsible for managing the terminals – generally the
person who installs the network and the application program.
Constant attention to the indications contained in the manual will guarantee the
user’s safety, working efficiency and a longer functional life for the terminal.
Formula 8500 - USER MANUAL
__________________________________________
1
Ed.: 01/99
2
1.2 ENCLOSED DOCUMENTS
The documents listed in the following table are enclosed with the manual.
1.3 PACKAGE CONTENTS
The terminal package contains:
- No. 1 F8500 terminal;
- No. 1 User’s manual and attached documentation;
- No. 1 battery pack;
- No. 1 box for 3 alkaline batteries
Any other packages will contain the accessories necessary for the terminal connec-
tion to the host computer and to the network: the cradle, power supply, and one
or more connection cables.
Remove all the components from their packaging, check their integrity and congru-
ity with the packing documents.
Keep the original packaging for use when sending products to the technical assis-
tance centre. Damage caused by improper packaging are not covered under the
guarantee.
DOCUMENT TYPE
RECEIVER
User
Terminals
Manager
Programmer
Declaration of conformity
Menu & Commands Booklet for
8500
Test chart
Formula products customer ser-
vice form
GENERAL INFORMATION
______________________________________________
1
Ed.: 01/99
3
1.4 TERMINAL MANUFACTURER AND MODEL IDENTIFICATION
Serial Number
2007900111
F8500
****
140734500
Volt
Code
Model identification
and serial number
Model description
Ed.: 01/99
4
2
2.1 TERMINAL DESCRIPTION
The Formula 8500 is the new Hand-held PC with integrated laser scanner based on
PC technology designed by Datalogic S.p.a.
The Formula 8500 is capable of reading all common barcode symbologies, includ-
ing the new PDF-417 two-dimensional codes as option.
The user accessible Type-II PCMCIA slot allows for simple installation of modems,
Ethernet and Token Ring adapters, and solid state disk using the standard PC Card
technology.
The Formula 8500 is equipped with an IrDA port for short-range wireless infrared
communication with portable printers and other devices that support this kind of
interface
The Formula 8500 is equipped whit a back-light
LCD graphic display, with 160 by 240 pixels reso-
lution, and an ergonomic alphanumeric key-
board. In addition, for pen-based applications, an
optional touch screen is available which allows
even for functions that require signature capture
or mouse emulator.
TECHNICAL INFORMATION
____________________________________________
2
Ed.: 01/99
5
2.2 TECHNICAL CHARACTERISTICS
Optical Characteristics - laser 1D
Optical Characteristics - laser 2D
Electrical characteristics
Light source laser scanner VLD source, 670 nm
Scan rate 36 ± 3 scan/sec
Minimum resolution 0.13 mm
Skew or yaw angle ± 65°
Pitch or Roll angle ± 55°
Depth of field
((depends on the type and density of the code)
30 ÷ 800 mm
Light source laser scanner VLD source, 670 nm
Scan rate 570 ± 20 scan/sec
Frame rate 25 frames/sec
Minimum resolution 0.15 mm
Skew or yaw angle ± 15°
Pitch or Roll angle ± 30°
Depth of field
(depends on the type and density of the code)
75 ÷ 300 mm (2D codes)
120 ÷ 700 mm (1D codes)
Micro-controller 32 bit - AMD 486
Memory BIOS-DOS 512KB Flash memory
Disk memory 2/4/8 MB
RAM 2/4 MB DRAM
EEPROM 256 Bytes
Calendar/clock quartz RTC, time and date program-
mable with automatic management
of leap years.
Power supply NiMH battery pack, 1350 mAh or 3
AA alkaline batteries.
Battery charge Formula 985
Formula 8500 - USER MANUAL
__________________________________________
2
Ed.: 01/99
6
Physical characteristics
Environmental Conditions
Programming
Technology SMT (Surface Mounting Technology)
Dimensions (LxWxH) 212 x 74 x 50/34.5 mm
Weight 370 grams with NiMH batteries, 1-D
laser scanner without radio;
Buzzer piezoelectric buzzer
LED Red/green LED
Display high contrast, graphic LCD with
160x240 dot matrix, back-light
Keyboard 41 keys in silicone covered rubber, reset key
Temperature working temperature 0° up to +45°C
storage -20° up to +60°C
(-20° ÷ +35°C for long term battery storage)
Relative Humidity 95% without condensation
Degree of protection EN 60529 (IP 51)
Electrostatic discharge IEC 1000-4-2 (up to 15KV on air)
Resistance to falls IEC 68-2-32 (up to 1.2 m on concrete)
Safety standards IEC 825 (class 2 laser product)
Operating system DOS 6.22
Decoded bar codes - laser 1D EAN-8, + add-on-2, + add-on-5
EAN-13, + add-on-2, + add-on-5
UPC/A, + add-on-2, + add-on-5
UPC/E, + add-on-2, + add-on-5
Interleaved 2 of 5 (ITF)
Codabar - Monarch - NW7 - 2 of 7
Code 39
Code 128
MSI
TECHNICAL INFORMATION
____________________________________________
2
Ed.: 01/99
7
Communication characteristics
RF Communication Characteristics
Decoded bar codes - laser 2D EAN-8, + add-on-2, + add-on-5
EAN-13, + add-on-2, + add-on-5
UPC/A, + add-on-2, + add-on-5
UPC/E, + add-on-2, + add-on-5
UCC/EAN 128
Interleaved 2 of 5 (ITF)
Codabar - Monarch - NW7 - 2 of 7
Code 39
Code 39 full ASCII
Code 93
Code 128
MSI
PDF 417
Optical Interface IrDA 1.0
F985 Interface cradle-terminal interface via IrDA
Cradle-Host Interface RS-232
RS-485
Eavesdrop
Maximum speed of transmission 115 Kbit/sec max
Frequency 2.4 GHz
Power output 100 mW Max
In compliance with ETS 300-328
Ed.: 01/99
8
3
Read carefully this manual before performing any type of connection or repair on
the terminal.
The user is responsible for any damages caused by incorrect use of the equipment
or by inobservance of the indication supplied in this manual.
3.1 GENERAL SAFETY RULES
As with all high-intensity light sources, the laser beam used on this terminal can
be dangerous for one’s eyesight if looked at directly or for long periods of time.
For this reason, avoid directing the laser beam towards your eyes or those of
other people or animals.
Use only the components supplied by the manufacturer for the specific terminal
being used. The use of cradles other than those supplied with the terminal or in-
dicated in the list in the appendix could cause serious damage to the terminal.
A Follow the procedures for using and storing the terminal indicated in the Tech-
nical Specifications.
SAFETY REGULATIONS
________________________________________________
3
Ed.: 01/99
9
3.2 MAINTENANCE SAFETY
Do not attempt to disassemble it, as it does not contain parts that can be re-
paired by the user. Any tampering will invalidate the guarantee.
When replacing the batteries or at the end of the operative life of the terminal,
disposal must be performed in compliance with the law in force.
Do not submerge the terminal in liquid products.
3.3 DANGER SIGNALS
CAUTION
Be sure the danger labels applied on the terminal are readable at all times. If
necessary, replace them with new ones.
Formula 8500 - USER MANUAL
__________________________________________
3
Ed.: 01/99
10
This device uses a class 2 IEC 825 laser
emitter.
3.4 U.S. FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY
INTERFERENCE STATEMENT - INFORMATION TO THE USER
INFORMATION
This equipment has been tested and found to comply with the limits for a Class
B digital device pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interfer-
ence in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may causes harmful inter-
ference to radio communications.
However, there is no guarantee that interference will not occur in a particular in-
stallation.
If this equipment does cause harmful interference to radio or television reception,
which can be determinated by turning the equipment off and on, the user is en-
couraged to try to correct the interface by one or more of the following measures:
- Re-orient the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet of a circuit different from that to which
the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for assistance.
- Changes or modification not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
- Connecting of peripherals requires the user of grounded shielded signal cables.
Ed.: 01/99
11
4
4.1 TERMINAL CONNECTION TO THE HOST COMPUTER
CAUTION
Before continuing with this phase, be sure both the computer and the terminal
are turned off.
4.1.1 RS-232 Connection
To install the program on the terminal (thus making it operative), carry out the nec-
essary physical connections as indicated below:
1 - take out the cable contained in the cradle package and connect it to the COM1
serial port (or another available serial port) using connector DB9;
2 - connect the other end of the same cable to the RS-232 port of the cradle, with
the RJ connector;
3 - insert the power-supply plug into the outlet on the base of the cradle;
4 - attach the power supply to a power outlet and turn on the cradle and the com-
puter.
Formula 8500 - USER MANUAL
__________________________________________
4
Ed.: 01/99
12
5 - put the terminal into its cradle and, if necessary, recharge the battery.
Key:
A) Host computer
B) Cradle F985
C) Cradle power supply
FPS14
A
B
C
CONNECTIONS
________________________________________________________
4
Ed.: 01/99
13
4.1.2 Other types of connection
The use of the connections illustrated below depends on the features of the
program loaded on the terminal. For more detailed information, please read the
software manuals carefully.
Connection with the Eavesdrop Interface
This connection enables the terminal to be connected on an existing asynchronous
RS-232 line (for example between the host computer and a video terminal).
Key:
A) Video terminal
B) Host Computer
C) Cradle F985
D) Cradle power supply
RS-485 Connection
Allows for the connection of more terminals on a single RS-232 line through the
installation of a Sysnet network.
If the Sysnet network is made using the Formula 902 T-Box, up to 32 Formula
cradles can be connected, including different types (if multiple cradles are used, the
individual work stations must be counted).
FPS14
A
B
C
D
Formula 8500 - USER MANUAL
__________________________________________
4
Ed.: 01/99
14
Key:
A) Host computer
B) Formula 902 T-box
C) Cradle F985
D) Cradle power supply
E) Formula 904/N Interconverter
FPS14
Formula 904/N
Formula 902
Formula 902
FPS14
Formula 902
Power Supply
A
B
C
D
E
CONNECTIONS
________________________________________________________
4
Ed.: 01/99
15
RF Connection
This allows the terminal to be connected to the host computer via radio frequency
using the RF PCMCIA module that is with the F8500 (only for RF version), and an
Access Point connected to the host computer
Key:
A) F8500
B) Access Point
APPLICATION SERVER
ETHERNET - TOKEN RING
ACCESS POINTS ACCESS POINTS
SEAMLESS ROAMING
A
B
Formula 8500 - USER MANUAL
__________________________________________
4
Ed.: 01/99
16
4.2 CRADLE F985
Only the F985 cradle can be used with the Formula 8500 terminal:
Key F985 standard:
A) IrDA window
B) Two-color LED – spare battery slot
C) Terminal-recharge contacts
D) Two-color LED – terminal battery
E) Contacts for recharging the spare battery
F) Connectors for connecting to the host computer
G) Power-supply connector
A
B
C
D
E
F
G
F
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Datalogic Formula 8500 Manuale utente

Categoria
Lettori di codici a barre
Tipo
Manuale utente

in altre lingue