DRAGON™ M SERIES
11
DRAGON™ M DEFAULT CONFIGURATION
DATA FORMAT
code identifier disabled, field adjustment disabled, code length not
transmitted, character replacement disabled, time stamping disabled, time
stamping delimiter disabled
READING PARAMETERS
hardware trigger, trigger active level, no trigger timeout, one read per cycle,
safety time 0.5 sec, beeper intensity high, tone 2, aiming spot = disabled
DISPLAY/KEYPAD PARAMETERS
Font size = small, display timeout = 8 sec., backlight = off, display mode =
local echo, keypad enabled, KeyID characters: left = '<', center = '=', right = '>'
DECODING PARAMETERS
ink spread enabled, overflow control enabled, interdigit control enabled,
decoding safety = one read, Puzzle Solver™ disabled
CODE SELECTION
enabled codes
• EAN 8/EAN 13 / UPC A/UPC E without ADD ON
check digit transmitted, no conversions
• Interleaved 2/5
check digit control and transmission, variable length code; 4-99
characters
• Standard Code 39
no check digit control, variable length code; 1-99 characters
• Code 128
variable length code; 1-99 characters
disabled codes
EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, RSS codes,
MSI, Plessey, Telepen, Delta IBM, Code 11, Code 16K, Code 49
ADVANCED FORMATTING PARAMETERS
concatenation disabled, no advanced formats defined
RADIO PARAMETERS
radio protocol timeout = 2 seconds, power-off timeout = 4 hours, transmission
mode = one-way, beeper control for radio response = normal, single store
disabled, batch mode disabled