Metrologic MS951 Programming Manual

Categoria
Lettori di codici a barre
Tipo
Programming Manual
METROLOGIC INSTRUMENTS, INC.
MS951 Hand-Held Laser Scanner
Including All Scanner Configurations
Programming Guide
ii
Locations
CORPORATE HEADQUARTERS
North America Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO
90 Coles Road Tel: 856-228-8100
Blackwood, NJ 08012-4683 Fax: 856-228-6673
Internet: www.metrologic.com
EUROPEAN HEADQUARTERS
Germany, Metrologic Instruments GmbH Tel: +49 89 89019 0
Middle East and Africa Dornierstrasse 2 Fax: +49 89 89019 200
82178 Puchheim b. Email: info@europe.metrologic.com
Munich, Germany Germany Email: [email protected]
Spain Metrologic Eria lbérica SL Tel: +34 913 272 400
Julián Camarillo 29, D-1 Fax: +34 913 273 829
Edificio Diapasón Email: [email protected]om
28037 Madrid
Italy Metrologic Instruments Italia srl Tel: +39 0 51 6511978
Via Emilia 70 Fax: +39 0 51 6521337
40064 Ozzano dell’Emilia (BO) Email: [email protected]
France Metrologic Eria France SA Tel: +33 (0) 1 48.63.78.78
69 Rue de la Belle Etoile Fax: +33 (0) 1 48.63.24.94
ZI Paris Nord II, BP 50057 Email: [email protected]
95947 – ROISSY CDG CEDEX
United Kingdom Metrologic Instruments UK Limited Tel: +44 (0) 1256 365900
58 Tempus Business Centre Fax: +44 (0) 1256 365955
Kingsclere Road, Basingstoke Email: [email protected]
Hampshire RG21 6XG
ASIA
Singapore Metrologic Asia (Pte) Ltd Tel: 65-6842-7155
No. 8 Kaki Bukit Place Fax: 65-6842-7166
4
th
Floor Email: [email protected]ic.com
Singapore 416186
China Metro (Suzhou) Technologies Co., Ltd. Tel: 86-512-62572511
221 Xing Hai Street Fax: 86-512-62571517
Suzhou Industrial Park Email: [email protected]
Suzhou, China
215021
Japan Metrologic Japan Co., Ltd. Tel: 81-03-3839-8511
Matsunoya Building, 6 Floor Fax: 81-03-3839-8519
3-14-8 Higashiueno Email: [email protected]
Taitou-Ku, Tokyo 110-0015 Japan
SOUTH AMERICA
Brazil Metrologic do Brasil Ltda. Tel: 55-11-5182-8226
Rua da Paz 2059 Fax: 55-11-5182-8315
CEP 04713-002 Email: info@br.metrologic.com
Chácara Santo Antônio
São Paulo, SP, Brasil
Outside Brazil Metrologic South America Tel: 55-11-5182-7273
Rua da Paz 2059 Fax: 55-11-5182-7198
CEP 04713-002 Email: info@sa.metrologic.com
Chácara Santo Antônio
São Paulo, SP, Brasil
Copyright
© 2002 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in
any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or
provided for in the Copyright Act of 1976.
Products and brand names mentioned in this document are trademarks of their respective companies.
iii
Table of Contents
Scope of the MS951 Programming Guide..................................................... 1
Programming the Scanner ............................................................................. 2
Enter Program Mode..................................................................................... 3
Recall Defaults.............................................................................................. 3
Laser Activation Range................................................................................. 4
Laser Operation............................................................................................. 4
Same Symbol Re-Scan.................................................................................. 5
Identical Symbol Re-Scan Indicator ............................................................. 5
1 vs. 2 Scan Buffers ...................................................................................... 5
Decode Options............................................................................................. 6
Beeper Tones ................................................................................................ 7
Audible Indicators for Communication Timeouts......................................... 8
RS-232 Interface ........................................................................................... 9
RS-232 Parameter - Baud Rate ..................................................................... 9
RS-232 Parameter - Parity .......................................................................... 10
RS-232 Parameter - Data Bits..................................................................... 10
RS-232 Parameter - Hardware Handshaking .............................................. 11
RS-232 Parameter - Software Handshaking................................................ 11
Intercharacter Delay.................................................................................... 12
RS-232 Parameter - Scanning Control (DTR Signal) ................................. 13
“DE” Disable Command............................................................................. 13
iv
Longitudinal Record Redundancy Check (LRC) ........................................ 14
Record Header/Terminator Select......................................................... 14, 15
UPC/EAN Identifiers .................................................................................. 16
Keyboard Wedge (KB) Interface ................................................................ 17
KB Parameter - Keyboard Type.................................................................. 17
KB Parameter - Keyboard Country Type.................................................... 18
KB Parameter - Caps Lock Mode ............................................................... 20
KB Parameter - Alt Mode ........................................................................... 20
KB Parameter - Inter Scan Code Delay (AT and PS/2 Modes)................... 21
KB Parameter - XT - Clean-Up Bit............................................................. 21
Record/Header Terminator Select......................................................... 22, 23
Intercharacter Delay.................................................................................... 23
KB Parameter - Special Features ................................................................ 24
OCIA Options............................................................................................. 25
IBM 46XX Options..................................................................................... 26
IBM 46XX Parameter - Inter Record Delay ............................................... 26
Light Pen Options ....................................................................................... 27
Light Pen Emulation ................................................................................... 28
Code Type Selections ............................................................................28-30
Minimum Code Length for All Code Types ............................................... 31
Code Length Minimum Feature .................................................................. 31
UPC/EAN Code.......................................................................................... 32
v
UPC-A Options........................................................................................... 32
UPC-E Options ..................................................................................... 33, 34
UCC Supplemental Options........................................................................ 34
Supplemental ISBN Options....................................................................... 35
Coupon Code 128 ................................................................................. 35, 36
Code 39................................................................................................. 36, 37
Codabar....................................................................................................... 37
Interleaved 2 of 5 (ITF)............................................................................... 38
Interleaved 2 of 5 (ITF) Symbol Lengths...............................................39-41
ITF Minimum Symbol Length Test ............................................................ 42
MSI Plessey Check Digit ...................................................................... 42, 43
UK Plessey Options .................................................................................... 43
ScanPal Data Collector ............................................................................... 44
Test Modes.................................................................................................. 44
Special Features .....................................................................................45-47
User Programmable Prefix and Suffix ID Characters ................................. 48
RB0 - RB9 Bar Codes................................................................................. 49
ASCII Reference Table.......................................................................... 50-54
PC Extended Reference Key Tables ..................................................... 55, 56
Reserved Codes...................................................................................... 57-68
Disclaimer................................................................................................... 69
Index ...................................................................................................... 70-72
1
Scope of the MS951 Programming Guide
This Manual contains all of the configuration codes for all versions of the
MS951 hand-held bar code scanner products.
Not all hardware versions of the scanner support all of the features
universally. PC Keyboard Wedge units
do not use baud rates. Light Pen
emulation scanners
should not try to drop UPC/EAN check digits. Some
features will deliver different results based upon the primary interface
selected.
Emphasis will be placed on PC Keyboard Wedge and RS-232 applications.
Keyboard Wedge units default to Keyboard Wedge communications. All
other units default to RS-232 parameters.
2
Programming the Scanner
The scanner is shipped from the factory programmed to a set of default
conditions noted in this guide by an asterisk that appears before the brief
definition. Since each host system is unique, the scanner has to be
configured to match your host system requirements.
1. Connect the scanner to the host system or power source.
(Refer to the Installation and User’s Guide MLPN 2365.)
2. Scan the ENTER/EXIT PROGRAM MODE bar code.
(The unit will beep three times.)
Enter/Exit
Program Mode
3. Scan by positioning the output window within two inches of each
code. (When the first menu selection has been scanned, the laser will
stay on until the ENTER/EXIT PROGRAM MODE code is scanned
again. If no scanning occurs for 30 seconds while the scanner is in
program mode, the unit will beep three times and all changes made
will be lost. If this occurs, return to Step 1.)
4. Upon completing the scanning of the appropriate configuration
options, scan the ENTER/EXIT PROGRAM MODE bar code again.
(The new options will be saved and the scanner is ready for normal
operation.)
Note: While in program mode, the scanner will make a Α razz sound
when:
¾ the bar code it is scanning is not a program mode code type;
¾ the feature is not currently supported in the firmware;
¾ the feature is not supported on the scanner’s hardware
configuration.
The sound serves as an audible indication that the scanner will not
support that feature.
**
Recall Defaults
3
DF1
Enter Program Mode
**Ability to Enter Program When this option is selected, pro-
Mode After Any Scan gramming can be entered by scann-
gin the ENTER/EXIT PROGRAM
MODE bar code after power up or
during normal scanning operation.
Enter Program Mode When this option is selected, the
Only on First Scan scanner will only enter program
mode after power-up. Scan the
ENTER/ EXIT PROGRAM MODE
bar code immediately after the scan-
ner first receives power. This option
prevents the scanner from accident-
ally entering program mode during
normal scanning operation.
Recall Defaults
If during programming of the scanner,
there is a need to return to the original Recall Defaults
factory settings, scan the RECALL
DEFAULTS bar code. Any settings
selected during that session or a
previous session will be lost.
R18
R19
DF1
Enter/Exit Program Mode
4
**
Laser Activation Range
Short Range Activation When this option is selected, the IR sensor
Out of the Stand is guaranteed to be activated when the posi-
tion of the scanning window three inches
from the object.
Short Range Activation When this option is selected, the IR sensor
In the Stand is guaranteed to be activated when an object
is presented three inches from the scanning
window.
**Long Range Activation When this option is selected, the IR sensor
Out of the Stand is guaranteed to be activated when the
position of the scanning window is eight
inches from the object.
**Long Range Activation When this option is selected, the IR sensor
In the Stand is guaranteed to be activated when an object
is presented eight inches from the scanning
window.
Laser Operation
** Normal Scan This option is the default setting. When the laser is
activated by the IR sensor, the laser beam emits from
the output window and displays a constant, horizontal
line until a bar code is sensed or until the scanner
timeout elapses.
Pulsing Scan When the laser is activated by the IR sensor, the laser
beam emits from the output window and displays a
horizontal line that pulses until a bar code is sensed or
until the scanner timeout elapses.
Custom Scan This option is available for special applications.
Do not scan the CUSTOM SCAN bar code unless
instructed by a Metrologic representative.
RS1
RS3
RS2
RS4
RS5
RS6
LP8
Recall Defaults
5
DF1
Same Symbol Re-Scan
The scanner is programmed with a same symbol timeout.
For SHORT SAME SYMBOL RE-SCAN, the time
Symbol Re-Scan
delay is 2 second, while the LONG SAME SYMBOL
RE- SCAN delay is 1 second. These numbers represent
how much time that a bar code must be out of the scan
field before that bar code can be scanned again.
** Long Same
Symbol Re-Scan
Identical Symbol Re-Scan Indicator
During the same symbol timeout, the LEDs does ** Disable Green LED
not provide an indication of when the unit is ready to
begin scanning the same symbol again. To program
a LED to flash when the preset delay is over, configure
the scanner to Green LED Enabled.
Enable Green LED
1 vs. 2 Scan Buffers
This feature controls the number of bar codes Enable 2 Scan Buffers
considered for the purposes of the same symbol
re-scan. The default, 1 scan buffer only compares
new scanned data against the last bar code scanned.
2 scan
buffers allow the scanner to test the last
2 bar codes scanned for same symbol re-scan **Enable 1 Scan Buffer
purposes.
R30
R31
EX6
EX5
R92
R93
Enter/Exit Program Mode
6
**
Decode Options
Enable 2X Redundancy (MECCA)
R86
*Disable 2X Redundancy (MECCA)
R87
The following bar codes are very useful when working with Code 39 and
Codabar applications.
Enable Double Border Requirement
(large inter-character space requirement)
RAN
**Disable Double Border Requirement
(large inter-character space requirement)
RAO
Recall Defaults
7
DF1
Beeper Tones
The scanner can be programmed to emit a certain tone. If necessary, scan
the appropriate bar code on page 3.
Alternate Tone 1 .................................................. Low Tone
Alternate Tone 2 .................................................. High Tone (Default)
Alternate Tone 3 .................................................. Medium Tone
No Tone
Alternate Tone 1
BP1
**Alternate Tone 2
BP2
Alternate Tone 3
BP3
No Tone
BP4
Enter/Exit Program Mode
8
**
Audible Indicators for Communication Timeouts
Two Second Timeout When this option is selected, the scanner will
timeout if it does not transmit its data to the
host after two seconds during communication.
This is only valid in modes where some type
of
** No Two Second handshaking is involved.
Timeout
Razz Beep on Timeout When this option is selected, the scanner will
produce an audible razzberry tone when
communications have timed out.
** No Tone On Timeout
OC8
Three Beep on Timeout When this option is selected, the scanner will
beep three times when communications have
timed out.
** Beep Before Transmit When this option is chosen, the scanner will
beep before each label is transmitted.
Beep After Transmit When this option is chosen, the scanner will
beep after each label is transmitted.
Generally used in conjunction with 2
second communications time out.
Especially useful with OCIA and IBM
46XX applications.
OC 7
OC 9
OC5
OC6
R50
R51
Recall Defaults
9
DF1
RS-232 Interface
** Enable RS-232 Interface
RS-232 Parameter - Baud Rate
A baud rate is a unit that measures the speed with which information is
transferred. The baud rate of the scanner must equal the baud rate of the
host device. The available baud rates range from 300 to 38400.
300 Baud Rate
BR2
600 Baud Rate
BR3
1200 Baud Rate
BR4
2400 Baud Rate
BR5
4800 Baud Rate
BR6
**9600 Baud Rate
BR7
19200 Baud Rate
BR8
38400 Baud Rate
LP2
BR1
Enter/Exit Program Mode
10
**
RS-232 Parameter - Parity
Parity is an additional digit that makes the number of bits in the ASCII code
odd or even. The scanners parity must match the hosts parity.
**Space Parity Select this option to make the parity bit always 0.
PA1
Even Parity Select this option to make the additional parity bit either
a 0 or 1 to guarantee an even number of bits.
Mark Parity Select this option to make the parity bit always 1.
PA2
Odd Parity Select this option to make the additional parity bit either
a 0 or 1 to guarantee an odd number of bits.
RS-232 Parameter - Data Bits
RS-232 serial communication requires ASCII data to 8 Data Bits
be transmitted in either 7 or 8 data bits. In addition,
one parity bit will be transmitted. If necessary, scan the
appropriate bar code that matches your host devices
requirements.
Generally, if 7 data bits are selected, 2 stop bits are
** 7 Data Bits
transmitted. If 8 data bits are selected, 1 stop bit is
transmitted. Stop bits are actually just an idle trans-
mit line. From the scanners perspective, they are only
important if the scanner is receiving more than 1 byte
of information at a time. For most applications, the
scanner is a transmit only device.
PA3
PA4
D81
D82
Recall Defaults
11
DF1
RS-232 Parameter - Hardware Handshaking
To prevent scanned information from being lost Enable RTS/CTS
during transmission, your host device may require
an RTS/CTS signal. When the RTS/CTS (Request
To Send/Clear To Send) is enabled, the scanner
will output an RTS signal and wait for a CTS ** Disable RTS/CTS
signal before any data is transmitted. The default
setting of RTS/CTS is disabled. If necessary, scan
the ENABLE RTS/CTS bar code.
** Character RTS/CTS
activate and .
Message RTS/CTS When this option is chosen, the scanner will
activate and deactivate its RTS signal on each
message that it transmits. This mode should
normally be enabled for Sanyo registers.
RS-232 Parameter - Software Handshaking
For control of the data transmission process, use ACK/NAK or XON/XOFF
instead of or in addition to the RTS/CTS hardware handshaking option.
Enable ACK/NAK When this option is enabled, the scanner will not
scan again unless an ACK (ASCII 06H) is
received after transmission of a bar code. If an
NAK (ASCII 15H) is received, the scanner will
** Disable ACK/NAK retransmit the bar code.
Enable XON/XOFF When this option is enabled, the scanner will
stop transmission whenever an XOFF (ASCII
13H) is received. Transmission will resume after
an XON (ASCII 11H) is received.
** Disable XON/XOFF
HH1
HH2
R56
R57
SH2
SH1
SH4
SH3
Enter/Exit Program Mode
12
**
Intercharacter Delay
The time specified with an Intercharacter delay bar code represents the
interim of time between transmission of characters. Some host systems
require this delay when receiving transmissions, others do not. If necessary,
scan the appropriate bar code.
No Intercharacter Delay
R20
**1 Millisecond Intercharacter Delay
R21
5 Millisecond Intercharacter Delay
R22
25 Millisecond Intercharacter Delay
R23
Recall Defaults
13
DF1
RS-232 Parameter - Scanning Control (DTR Signal)
When the DTR (Data Terminal Ready) input Enable DTR Input
is enabled, the scanner will not transmit unless
an active (+12V) DTR signal is present on the
scanners DTR input pin. The scanner can be
disabled by making DTR inactive (-12V) at
** Disable DTR Input
the DTR input pin.
The DTR Scan Disable feature will prevent
any scanning when the Enable DTR input
Enable DTR Scan Disable
feature is chosen. Before enabling the Enable
DTR Scan Disable feature, first scan the EN-
ABLE DTR INPUT bar code. To turn off this
feature, scan the Recall Defaults bar code.
"DE" Disable Command
Enable "DE"
Disable Command
When this option is enabled, the scanner will stop scanning when it receives
an ASCII "D" from the host device. Scanning will resume when the scanner
receives an ASCII "E". This feature will only work with RS-232
communication.
*Disable "DE"
Disable Command
When this option is chosen, the scanner will not stop scanning when it
receives an ASCII "D" from the host device.
HH3
HH4
R32
R95
R94
Enter/Exit Program Mode
14
**
Longitudinal Redundancy Check (LRC)
A Longitudinal Redundancy Check (LRC) is an Enable LRC Calc+
error checking character that is calculated across Transmit RS232
a sequence of data characters. It is determined by
eXclusive ORing (XOR) the characters to be
checked, starting with an initial value of 00H.
**Disable LRC Calc+
The result, an "LRC byte" is then transmitted Transmit RS232
following the data stream and used by the receiving
computer to determine if the information was received
correctly. In the scanner's case, XOR is performed
prior to adding parity bits.
Start LRC on
First RS232 Byte
When the LRC is enabled, the scanner defaults to
starting the LRC on the second byte of information
transmitted. Optionally, the calculation can start on
**Start LRC on
the first byte transmitted. Second RS232 Byte
Record Header/Terminator Select
** CR On When this option is on, the scanner will transmit a
Carriage R
eturn after each bar code.
CR Off
** LF On When this option is on, the scanner will transmit a Line
Feed after each bar code.
LF Off
R58
R59
RA0
R99
TR2
TR1
TR3
TR4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79

Metrologic MS951 Programming Manual

Categoria
Lettori di codici a barre
Tipo
Programming Manual

in altre lingue