Vemer Mithos GSM RF Bianco Manuale utente

Tipo
Manuale utente

Questo manuale è adatto anche per

Cronotermostato
Digitale
Mithos GSM RF
Manuale d’Uso
User Manual
DIGITAL CHRONOTHERMOSTAT
English
- 1 -
Mithos GSM RF Chronothermostat User Manual
Assembly Page 4
Dimensions Page 5
Connection diagram Page 5
Safety warnings Page 6
Technical characteristics Page 6
Control elements / display indications Page 7
Initial start-up / Reset Page 10
Clock setting Page 13
Programs setting Page 15
Temperatures setting Page 17
Manual operation Page 18
Summer / winter operation Page 19
Mithos GSM RF turning off from keyboard Page 20
Timings Page 20
Advanced programming Page 22
Advanced functions Page 31
Regulation type Page 34
GSM interface Page 36
Managing the chronothermostat Page 39
Managing the alarms Page 45
Backup battery Page 51
Reference standards Page 51
Winter programs Page 52
Summer programs Page 53
Index
English
- 2 -
Mithos GSM RF Chronothermostat User Manual
Mithos GSM RF digital chronothermostat
Power supply: 230 V AC
(with rechargeable backup battery
NiMh type AA)
Comfort and control of consumptions
are ensured both in winter and in
summer (heating/air conditioning)
Integrated GSM module for the remote
control of the chronothermostat
through your mobile
Interchangeable silver cover available
as accessory (code VE323200)
Installation can be wall or box 503
coverage (3 modules)
Display of the operation status, time,
day and internal and
external temperature
Weekly programming with three temperature
values controllable during the day
English
- 3 -
Mithos GSM RF Chronothermostat User Manual
Mithos GSM RF digital chronothermostat
Solution 1: Mithos GSM RF controls system via relay
1
1
2
2
7
7
...
...
boiler / conditioner
Mithos GSM RF
Mithos GSM RF
Mithos GSM RF
Mithos GSM RF
boiler / conditioner
boiler / conditioner
boiler / conditioner
actuators for other
loads
actuators for other
loads
Solution 2: Mithos GSM RF controls system via radiofrequency
Solution 3: Mithos GSM RF controls via relay system and other loads (up to 7)
via radiofrequency
Solution 4: Mithos GSM RF control system via radiofrequency and other loads
(up to 7) via radiofrequency
English
- 4 -
Mithos GSM RF Chronothermostat User Manual
ASSEMBLY
It is advisable to place the chronothermostat
in an area that mirrors, as much as possible,
the conditions of average temperature of
the entire environment. Avoid installing too
close to doors, windows, heat sources, direct
sunlight radiation and positions with excess
or total lack of air inlet.
It is moreover advised to install the
environment chronothermostat at about
150 cm from the floor and in an area in wich
the GSM signal is good.
Assembly can be wall or box 503 coverage
English
- 5 -
Mithos GSM RF Chronothermostat User Manual
DIMENSIONS
CONNECTION DIAGRAM
1
2
3
4
5
6
7
Ingresso per
X.Temp o DIG
COM
NA
NC
N
L
230 V~ 1
2
230 V ~
3
4
5
6
7
Input for
X.temp or DIG
COM
NA
NC
N
L
T3
T2
T1
132
95
36
English
- 6 -
Mithos GSM RF Chronothermostat User Manual
During installation and operation of the product, it is necessary to comply
with the following instructions:
1) The device must be installed by a skilled person, in strict compliance with the
connection diagrams.
2) Do not power on or connect the device if any part of it is damaged.
3) After installation, inaccessibility to the connection terminals without
appropriate tools must be guaranteed.
4) The device must be installed and activated in compliance with current electric
systems standards.
5) Before accessing the connection terminals, verify that the leads are not live.
6) The use of a GSM device can cause interference with the functioning of
electronic devices non-screened from radiofrequency signals (electromedical
devices, pacemakers, hearing aids etc.)
TECHNICAL CHARACTERISTICS
Power supply: 230 V AC (-15% ÷ +10%) 50/60Hz
Charge reserve: about 10 hours thanks to the backup battery
Backup battery:NiMH rechargeable type AA, capacity 2000 mAh or higher
Use rechargeable NiMH battery only
SAFETY WARNINGS
Mithos GSM RF is an electronic wall-mounting chronothermostat with GSM
module to be controlled remotely by sending an SMS or by using a suitable APP and
radiofrequency module to control the heating (or air-conditioning) system by sending a
radiofrequency signal to a remote actuator of Vemer range. The radiofrequency module
is used to associate the Mithos GSM RF up to 7 auxiliary actuators, which can be turned
on/off remotely with a simple SMS message. Mithos RF GSM executes actions of 1B
type and suitable for environments with a pollution degree 2 and overvoltage category III
(EN 60730-1).
Code Model Description
VE757000 Mithos GSM RF Nero
Wall-mounting chronothermostat GSM RF 230 V AC
VE756900 Mithos GSM RF Bianco
Wall-mounting chronothermostat GSM RF 230 V AC
VE323200 FR.Mithos Silver cover
English
- 7 -
Mithos GSM RF Chronothermostat User Manual
Auxiliary input configurable to connect alternately:
- a non-voltage contact (DIG)
- X.Temp external temperature probe
Output:
- 1 bistable relay with change-over contact 8A / 250V AC
- 1 radiofrequency channel to control the heating / air-conditioning system (to be used
as an alternative to the relay)
- 7 channels on radiofrequency to control the same number of remote actuators
5 temperature settings:
- T3, T2, T1 for automatic regulation
- T0 antifreeze temperature settable in advanced programming
- T temperature in manual operation
Temperature regulation:
- ON/OFF with differential settable between 0.1°C and 1°C
- PROPORTIONAL with settable proportional band and regulation period setting
Weekly programming
Daily resolution: 1h
Delay activation settable between 15, 30 and 45 minutes (independent for every hour)
Measured temperature scale:
– 0°C ÷ +50°C (internal probe)
– -40°C ÷ +60°C (external probe)
Measured and displayed temperature resolution: 0.1°C
Temperature regulation range: 2.0°C ÷ +50°C
Measurement update: every 20 seconds
Measurement precision: ± 0.5°C
Winter or summer or manual operation
Optional display in °F
Automatic change CET / DST
Password protected keypad lock for installation in public places
GSM quad band module (900 - 950 - 1800 - 1900 MHz)
Transmission frequency: 433.92 MHz (for RF signals)
Possibility to store up 5 numbers with which to control the device
Wall mounting (or on 503 type box)
Terminal block:
- Output: 3 poles 1.5mm
2
for bistable relay
- Input: 2 poles 1.5mm
2
for external probe or digital input
2 poles 1.5mm
2
for connection of the power supply
Operating temperature: 0 °C ÷ +50 °C
Operating humidity: 20% ÷ 90% non condensing
Storage temperature -10°C ÷ +65°C
Degree of protection: XXD
English
- 8 -
Mithos GSM RF Chronothermostat User Manual
5
10
2
1
3
4
6
9
11
12
13
8
7
Control elements
1) ” Key: manual operation
2) Key: increases the selected field
or displays the daily maximum
temperature
3) Key: decreases the selected field
or displays the daily minimum
temperature
4) ” Key: confirms the set data
5) ” Key: activation and deactivation of the chronothermostat
6) ” Key: selects temperature T3
7) ” Key: selects temperature T2
8) ” Key: selects temperature T1
9) Key: allows to set a timing or an activation delay
10) “ Key: programs setting or advanced programming
11) “ ” Key: clock setting
12) ” Key: winter operation (preset) or summer operation (the key is reachable
only with a point)
13) “ ” Key: deletes date and time but not the set programs (to do this see
"Restoring default parameters" page 33)
(the key is reachable only with a point).
CONTROL ELEMENTS / DISPLAY INDICATIONS
The preset temperature values (expressed in °C) are the following:
funct. winter funct. summer
T1 5.0 OFF
T2 15.0 23.0
T3 18.0 25.0
TMANUAL 20.0 24.0
Regulation of temperature levels is subjected to the following condition: T1 ≤ T2 ≤T3.
In summer mode, T1 cannot be set and corresponds to the air conditioning OFF.
English
- 9 -
Mithos GSM RF Chronothermostat User Manual
display indications
14) “Day”
Field
15) “External temperature”
Field
16) “Environment temperature”
Field
17) “Set program”
Field
18) “Manual operation activation”
Field
19) “Timings”
Field
20) Air conditioning activation”
Field
21) “Heating activation”
Field
22) “Clock”
Field
23) “Ring or incoming sms”
Field
24) “Gsm module status”
Field
25) “Unit of measurement”
Field
26) “Off”
Field
14 24 19
16
26
22
21
20 18
15
25
17
23
English
- 10 -
Mithos GSM RF Chronothermostat User Manual
INITIAL START-UP / RESET
Mithos GSM RF is a chronothermostat thought to be controlled remotely via SMS or
APP. To make this possible, it is necessary to have a SIM card of a telephone operator
to ensure a good coverage of GSM signal receiving.
1. Connecting the Mithos GSM RF to the GSM network
Mithos GSM RF is able to determine which operator ensures the best GSM coverage in
the area of installation.
Testing the GSM signal intensity
1. Turn on the Mithos GSM RF and make sure that no SIM card is inserted in the
housing
2. Press the “R” key and right after the key
3. The display shows “FLD” and then a screen like this:
Identifying operator Operator name
01 – 43 – 48 TIM
10 – 06 VODAFONE
88 – 44 WIND
99 – 33 3
4. Press the and keys to
scroll and check the intensity of the
signals of all detected operators.
5. To exit, press the “R” key
It is advisable to choose a SIM card of the
operator with the highest signal intensity.
Requirements of the SIM card
– It must be enabled to telephone traffic (voice, not SIM data)
it must have the PIN code request disabled (if necessary use a mobile phone to
disable the request)
– it must have the voice mail disabled
Identificativo
operatore
Intensità del segnale
Progressivo
operatore rilevato
Progressive
detected operator
Identifying
operator
Signal intensity
English
- 11 -
Mithos GSM RF Chronothermostat User Manual
Insert the SIM card into the housing in the
underside of the Mithos GSM RF, with the rounded
edge facing inwards and to the right, the housing is
of push-push type (push to insert the SIM card and
press to remove it).
The status of the connection to the GSM network is
symbolized by the icon on the display:
– lit fi xed: connected to the GSM network
lit blinking: SIM card not inserted, GSM network
coverage lack / GSM network search
2. Connecting the Mithos GSM RF to the heating system
Mithos GSM RF can control the heating / air conditioning system in two ways:
- via relay
- via radiofrequency (RF) signal to be sent to a remote actuato
Connection to the system via relay
Connect the relay output respecting the diagram on page 5.
Caution: before making connections, be sure to disconnect the power supply
Connection to the system via radiofrequency (RF)
The connection to the system via radiofrequency assumes to have a remote actuator
of Vemer range to be associated with Mithos RF GSM.
The activation of heating / air conditioning occurs via the remote actuator controlled
by the Mithos GSM RF by means of a radiofrequency signal.
To choose how to control the system, see page 27
3. Connecting the Mithos GSM RF to other actuators
Mithos GSM RF enables allows you to control via radiofrequency up to 7 independent
actuators.
This, coupled with the fact that the Mithos GSM RF can be controlled remotely via
GSM, implies that it is possible to control remotely up to 7 independent devices.
To do this you need to confi gure the connection between Mithos GSM RF and
actuators.
To choose how to control the system, see page 27
English
- 12 -
Mithos GSM RF Chronothermostat User Manual
4. Auxiliary input connection
The chronothermostat allows you to connect a remote external temperature probe
for the displaying (and possibly also regulation) of the temperature measured where
the probe is placed or a not in live contact in case you want to connect an auxiliary
external device (for example a gas detector, an anti-theft system, a block boiler
detection system, ...).
In this last case, a possible change of the input status can be signaled by sending
an SMS to a specified number (for more info, see “GSM INTERFACE” on page 36).
To configure the auxiliary external input, see page 26
English
- 13 -
Mithos GSM RF Chronothermostat User Manual
CLOCK SETTING
Press the key; on field (16)
seconds will run flashing, while field (22)
will display digits for minutes and hours.
Press the key to reset seconds
and increase the minutes field by 1 or
to reset the seconds field.
Press the key to confirm.
(In case the setting of the clock takes
place after a reset, the first parameter to
set will be the “ minutes" field).
At this point, the minutes digit will start flashing.
Use the and keys to increase or decrease the field and press to
confirm.
Repeat the procedure to set the hours.
Once the value for the hours is set, field (22) will display a flashing value of the year,
field (15) the value of the month and field (16) the value of the day.
English
- 14 -
Mithos GSM RF Chronothermostat User Manual
Press the and keys to modify the values and to confirm.
Once the day is set, press the key to exit the menu.
Upon exiting such procedure the clock indication will not flash any more; field (16) will
display the environment temperature again, while, if the external probe is connected,
field (15) will display the external temperature.
English
- 15 -
Mithos GSM RF Chronothermostat User Manual
PROGRAMS SETTING
Pressing the “ PRG ” key on field (14)
the indication regarding Monday will
be displayed, field (16) will display the
selected program flashing (in the example:
P1), field (15) will display “ Pro ”, field
(17) will display the graphic trend of the
corresponding program and will activate
symbol (20) or (21) depending on the set
operation (summer or winter).
If the selected program is correct, press the
key to continue to the next day.
If the selected program is not correct for
that day, you can create another one using
the and keys which modify
value “ Px ” contained in field (16); as the
program changes, so does the content of
field (17) regarding the selected program.
The default programs are listed at the end
of this manual.
Once the correct program is selected, press
the key to move on to the next day.
If no program satisfies the user's needs,
choose any program and press the
“ PRG ”
key again; this will bring the
segment of the corresponding field
(17)
to flash.
English
- 16 -
Mithos GSM RF Chronothermostat User Manual
With the
T1
,
T2
and
T3
keys, it is possible
to modify the temperature selected for
that hour and, at the same time, move on
to the next one. Using the
and
keys,
it is possible to move from
one hour to the next without modifying
the set temperature.
Pressing the
key,
it is possible
to set the activation delay for that
specific hour. Each pressure of the
key
increases the delay by 15
minutes.
Pressing the
key confirms
the modified program and returns to
the situation with
“ Px ”
flashing on
field
(16)
.
Pressing the
key confirms the
program for that day and moves on to
the next day until Sunday appears, after
which operation goes back to normal
mode.
English
- 17 -
Mithos GSM RF Chronothermostat User Manual
TEMPERATURES SETTING
In any of the operation modes, pressing
the
T1
,
T2
and
T3
keys will bring field
(22)
to display the writing corresponding to the
temperature that is being modified; on
field
(16)
the value of the aforementioned
temperature will flash.
With the
and
keys,
it is
possible to modify the value and with the
key
it is possible to confirm the
change and return to normal operation.
The setting limits for the set are reported in
the technical characteristics.
English
- 18 -
Mithos GSM RF Chronothermostat User Manual
MANUAL OPERATION
During automatic operation, when pressing the
key, the system will act as a
normal thermostat with operating temperature Tm.
Field
(22)
will show the current time.
Field
(14)
will show the current date.
Field
(15)
will display the writing
“ SEt ”
.
The symbol
(18)
will appear.
Field
(17)
will disappear. On field
(16)
the
set manual temperature value will flash.
With the
and
keys, it is
possible to change the value from 2.0°C
to 50°C.
Pressing the
key
or after 45
seconds from the last operation, field
(16)
will display the value of the environment
temperature, while field
(15)
will display
the external temperature value (if probe is
connected).
At any time, it is possible to verify the
set temperature pressing the
key
or the
key; pressing one of the 2
keys again will allow modification of the
temperature setting. To move from the
manual program to the automatic one,
simply press the
key again for at
least 3 seconds.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Vemer Mithos GSM RF Bianco Manuale utente

Tipo
Manuale utente
Questo manuale è adatto anche per

in altre lingue