Welch Allyn OSZ 3 Easy Directions For Use Manual

Categoria
Unità di pressione sanguigna
Tipo
Directions For Use Manual
Welch Allyn OSZ 3 Easy
Directions for Use
Wrist Watch Blood Pressure Monitor
Handgelenk-Blutdruckmessgerät
Tensiomètre bracelet-montre
Misuratore di pressione da polso
Tensiómetro Reloj de Pulsera
Monitor de Pressão Arterial de Pulso
PULSE
/min
DIA
mmHg
SYS
mmHg
OSZ 3
easy
O/I
ii
Copyright 2007 Welch Allyn. All rights are reserved. No one is permitted to
reproduce or duplicate, in any form, this manual or any part thereof without
permission from Welch Allyn.
Welch Allyn assumes no responsibility for any injury, or for any illegal or improper
use of the product, that may result from failure to use this product in accordance
with the instructions, cautions, warnings, or indications for use published in this
manual.
Welch Allyn
®
is a registered trademark of Welch Allyn.
Caution: Changes or modifications not expressly approved by Welch Allyn could
void the purchaser's authority to operate the equipment.
Mat. Number: OSZ3 Easy 55-A3-127, Ver: A
Model 7052-40
Welch Allyn GmbH & Co. KG
Zollerstrasse 2-4
D-72417 Jungingen, Germany
Tel. (+49) 7477-9271-0
Fax (+49) 7477-9271-90
e-mail: info@welchallyn.de
Printed in USA
The CE mark on this product indicates that it is in conformity with the
provisions of Council Directive 93/42/EEC.
European Regulatory Manager, Medical Division, Welch Allyn Ltd.,
Navan Business Park, Dublin Road, Navan, County Meath,
Republic of Ireland
Tel.: 353 46 90 67700
Fax: 353 46 90 67755
CONTENTS
Wrist Watch Blood Pressure Monitor . . . . . . . . . . . . . . . . .1
1. Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.1. Features of the device . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2. Important information about self-measurement . . . . . .1
2. Important information on the subject of blood-pressure and its
measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.1 How does high/low blood-pressure arise?. . . . . . . . . . .2
2.2 Which values are normal? . . . . . . . . . . . . . . . . . . . . . . .2
2.3. What can be done if regular increased/low values are
obtained?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3. The various components of the blood-pressure monitor . . . .5
4. Putting the blood-pressure monitor into operation. . . . . . . . .6
4.1. Inserting the batteries . . . . . . . . . . . . . . . . . . . . . . . . . .6
5. Carrying out a measurement . . . . . . . . . . . . . . . . . . . . . . . . .7
5.1. Before the measurement: . . . . . . . . . . . . . . . . . . . . . . .7
5.2. Common sources of error. . . . . . . . . . . . . . . . . . . . . . .7
5.3. Fitting the cuff. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
5.4. Measuring procedure . . . . . . . . . . . . . . . . . . . . . . . . . .9
5.5. Discontinuing a measurement . . . . . . . . . . . . . . . . . .10
5.6. Memory - storage and recall of the measurements . .10
6. Error messages/malfunctions. . . . . . . . . . . . . . . . . . . . . . . .10
7. Care and maintenance, recalibration . . . . . . . . . . . . . . . . . . .12
8. Guarantee. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
9. Reference to standards . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
10. Technical specifications: . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Handgelenk-Blutdruckmessgerät . . . . . . . . . . . . . . . . . . .17
1. Einführung. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
1.1. Besonderheiten des Gerätes . . . . . . . . . . . . . . . . . . . .17
1.2. Wichtige Hinweise für die Selbstmessung . . . . . . . . .17
2. Wichtige lnformationen zum Thema Blutdruck und dessen
Messung. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
iv Contents
2.1 Wie entsteht hoher/niedriger Blutdruck? . . . . . . . . . . .18
2.2. Welche Werte sind normal? . . . . . . . . . . . . . . . . . . . .19
2.3. Was ist zu tun, wenn regelmässig erhöhte/niedrige
Werte festgestellt werden?. . . . . . . . . . . . . . . . . . . . .20
3. Die verschiedenen Bestandteile des Blutdruckmessgerätes22
4. Inbetriebnahme des Blutdruckmessgerätes. . . . . . . . . . . . .23
4.1. Einsetzen der Batterien . . . . . . . . . . . . . . . . . . . . . . . .23
5. Durchführen einer Messung. . . . . . . . . . . . . . . . . . . . . . . . .24
5.1. Vor der Messung: . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
5.2. Häufige Fehlerquellen: . . . . . . . . . . . . . . . . . . . . . . . .24
5.3. Anlegen der Manschette. . . . . . . . . . . . . . . . . . . . . . .25
5.4. Messvorgang. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
5.5. Messung vorzeitig abbrechen . . . . . . . . . . . . . . . . . . .26
5.6. Benützung der Speicherfunktion. . . . . . . . . . . . . . . . .27
6. Fehlermeldungen/Störungen . . . . . . . . . . . . . . . . . . . . . . . .27
7. Pflege und Wartung, Nachkalibrierung . . . . . . . . . . . . . . . . .29
8. Garantie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
9. Normenverweis:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
10. Technische Daten:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Tensiomètre bracelet-montre . . . . . . . . . . . . . . . . . . . . . .33
1. Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
1.1. Caractéristiques du l’appareil . . . . . . . . . . . . . . . . . . . .33
1.2. Informations importantes pour prendre soi-même sa
tension artérielle . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
2. Informations importantes concernant la tension artérielle et sa
mesure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
2.1. Quelle est l’origine d’une tension basse/haute? . . . . .34
2.2 Quelles sont les valeurs normales? . . . . . . . . . . . . . . .34
2.3. Que faire lorsque les valeurs déterminées sont
régulièrement trop élevées/trop basses? . . . . . . . . . .36
3. Les différents éléments du tensiomètre . . . . . . . . . . . . . . .38
4. Mise en marche du tensiomètre. . . . . . . . . . . . . . . . . . . . . .38
4.1. Mise en place des piles. . . . . . . . . . . . . . . . . . . . . . . .38
5. Prise de mesure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
5.1. Avant d’effectuer une mesure: . . . . . . . . . . . . . . . . . .39
v
5.2. Sources d’erreur fréquentes: . . . . . . . . . . . . . . . . . . .40
5.3. Mise en place du brassard . . . . . . . . . . . . . . . . . . . . .40
5.4. Procédure de mesure . . . . . . . . . . . . . . . . . . . . . . . . .41
5.5. Interruption d'une mesure. . . . . . . . . . . . . . . . . . . . . .42
5.6. Mise en mémoire de la dernière mesure . . . . . . . . . .42
6. Messages d'erreur/problèmes de fonctionnement . . . . . . .42
7. Entretien, précautions et réétalonnage . . . . . . . . . . . . . . . . .44
8. Garantie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
9. Références aux normes . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
10. Données techniques: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Misuratore di pressione da polso . . . . . . . . . . . . . . . . . . .49
1. Introduzione . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
1.1 Caratteristiche di apparecchio. . . . . . . . . . . . . . . . . . . .49
1.2 Informazioni importanti sull'auto-misurazione . . . . . . .49
2. Informazioni importanti sulla pressione sanguigna e sulla sua
misurazione. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
2.1 Come varia la pressione sanguigna alta/ bassa? . . . . .50
2.2 Quali valori sono normali? . . . . . . . . . . . . . . . . . . . . . .51
2.3. Che cosa si può fare se si ottengono valori regolarmente
alti/bassi?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
3. I vari componenti del misuratore di pressione . . . . . . . .54
4. Messa in funzione del misuratore di pressione da polso . . .55
4.1. Inserimento delle batterie . . . . . . . . . . . . . . . . . . . . . .55
5. Effettuare una misurazione . . . . . . . . . . . . . . . . . . . . . . . . . .56
5.1 Prima della misurazione:. . . . . . . . . . . . . . . . . . . . . . . .56
5.2. Cause comuni d'errore:. . . . . . . . . . . . . . . . . . . . . . . .56
5.3. Applicazione della fascia da polso . . . . . . . . . . . . . . . .57
5.4. Procedura di misurazione . . . . . . . . . . . . . . . . . . . . . .58
5.5 Interruzione della misurazione prima del termine. . . . .59
5.6. Memoria - salvataggio delle ultime misurazioni . . . . .59
6. Messaggi d'errore/disfunzioni. . . . . . . . . . . . . . . . . . . . . . . .59
7. Cura e manutenzione, ritaratura . . . . . . . . . . . . . . . . . . . . . .61
8. Garanzia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
9. Standard di riferimento . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
vi Contents
10. Specifiche tecniche. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Tensiómetro Reloj de Pulsera . . . . . . . . . . . . . . . . . . . . . .65
1. Introducción . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
1.1 Características el dispositivo. . . . . . . . . . . . . . . . . . . . .65
1.2. Información inportante sobre las automediciones. . . .65
2. Información importante sobre la tensión arterial y su medición
66
2.1. ¿Cómo se origina la tensión arterial alta/baja?. . . . . . .66
2.2 ¿Cuáles son los valores normales? . . . . . . . . . . . . . . .67
2.3. ¿Qué puede hacerse si se obtienen valores altos/bajos
de forma regular?. . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
3. Los diversos componentes del tensiómetro . . . . . . . . . . . .70
4. Puesta en funcionamiento del tensiómetro . . . . . . . . . . . . .70
4.1. Inserción de las pilas . . . . . . . . . . . . . . . . . . . . . . . . . .70
5. Desarrollo de una medición . . . . . . . . . . . . . . . . . . . . . . . . .72
5.1. Antes de la medición: . . . . . . . . . . . . . . . . . . . . . . . . .72
5.2. Fuentes de error comunes:. . . . . . . . . . . . . . . . . . . . .72
5.3. Ajuste de la muñequera . . . . . . . . . . . . . . . . . . . . . . .73
5.4. Procedimiento de medición. . . . . . . . . . . . . . . . . . . . .73
5.5. Medición discontinua . . . . . . . . . . . . . . . . . . . . . . . . .74
5.6. Memoria - almacenamiento de la última medicion . . .75
6. Mensajes de error/funcionamiento defectuoso . . . . . . . . . .75
7. Cuidados y mantenimiento, recalibración . . . . . . . . . . . . . . .77
8. Garantia. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
9. Estándares de referencia . . . . . . . . . . . . . . . . . . . . . . . . . . .78
10. Especificaciones técnicas: . . . . . . . . . . . . . . . . . . . . . . . . .79
Monitor de Pressão Arterial de Pulso . . . . . . . . . . . . . . . .81
1. INTRODUÇÃO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81
1.1. Caracteristicas do Modelo dispositivo . . . . . . . . . . . . .81
1.2. Informações importantes sobre a auto-medição da
pressão arterial: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81
2. INFORMAÇÕES IMPORTANTES SOBRE A PRESSÃO
ARTERIAL E A SUA MEDIÇÃO: . . . . . . . . . . . . . . . . . . . . . .82
vii
2.1. Como ocorre a pressão arterial máxima e mìnima?. . .82
2.2 Quais são os valores considerados normais?. . . . . . . .83
2.3. O que fazer quando os registos obtidos são
frequentemente muito elevados ou muito baixos? . . .84
3. COMPONENTES DESTE APARELHO. . . . . . . . . . . . . . . . . .86
4. PÔR O APARELHO EM FUNCIONAMENTO . . . . . . . . . . . .86
4.1. Colocação das pilhas . . . . . . . . . . . . . . . . . . . . . . . . . .86
5. EFECTUAR UMA MEDIÇÃO . . . . . . . . . . . . . . . . . . . . . . . .87
5.1. Antes da medição:. . . . . . . . . . . . . . . . . . . . . . . . . . . .87
5.2. Causas frequentes de erro:. . . . . . . . . . . . . . . . . . . . .88
5.3. Aplicação da braçadeira de punho. . . . . . . . . . . . . . . .89
5.4. Método de Medição . . . . . . . . . . . . . . . . . . . . . . . . . .89
5.5 Interromper uma medição . . . . . . . . . . . . . . . . . . . . . .90
5.6. Memória - armazenamento e indicação das leituras. .91
6. MENSAGENS DE ERRO/MAU FUNCIONAMENTO . . . . . . .91
7. CUIDADOS E MANUTENÇÃO RECALlBRAÇÃO. . . . . . . . . .93
8. GARANTIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94
9. REFERÊNCIA ÀS NORMAS . . . . . . . . . . . . . . . . . . . . . . . . .94
10. ESPECIFICAÇÕES TECNICAS: . . . . . . . . . . . . . . . . . . . . . .95
viii Contents
1
Wrist Watch Blood
Pressure Monitor
1. Introduction
1.1. Features of the device
The blood-pressure monitor is a fully automatic, digital blood-
pressure measuring device for use on the wrist, which enables
very fast and reliable measurement of the systolic and diastolic
blood-pressure as well as the pulse frequency by way of the
oscillometric method of measuring.
The device offers a very high and clinically tested measurement
accuracy and has been designed to provide a maximum of user-
friendliness.
Before using, please read through this instruction manual
carefully and then keep it in a safe place. For further questions on
the subject of blood-pressure and its measurement, please
contact your doctor.
Attention!
1.2. Important information about self-measurement
Do not forget: self-measurement means control, not
diagnosis or treatment: Unusual values must always be
discussed with your doctor. Under no circumstances
should you alter the dosages of any drugs prescribed by
your doctor.
The pulse display is not suitable for checking the frequency
of heart pacemakers!
2 Wrist Watch Blood Pressure Monitor Welch Allyn
In cases of cardiac irregularity (Arrhythmia), measurements
made with this instrument should only be evaluated after
consultation with the doctor.
Electromagnetic interference
The device contains sensitive electronic components
(Microcomputer). Therefore, avoid strong electrical or
electromagnetic fields in the direct vicinity of the device (e.g.
mobile telephones, microwave cookers). These can lead to
temporary impairment of the measuring accuracy.
2. Important information on the subject
of blood-pressure and its measurement
2.1 How does high/low blood-pressure arise?
The level of blood-pressure is determined in a part of the brain,
the circulatory centre, and adapted to the respective situation by
way of feedback via the nervous system.
To adjust the blood-pressure, the strength and frequency of the
heart (Pulse), as well as the width of circulatory blood vessels is
altered. The latter is effected by way of fine muscles in the blood
vessel walls.
The level of arterial blood-pressure changes periodically during
the heart activity: During the «blood ejection» (Systole) the value
is maximal (systolic blood-pressure value), at the end of the
heart's «rest period» (Diastole) it is minimal (diastolic blood-
pressure value).
The blood-pressure values must lie within certain normal ranges
in order to prevent particular diseases.
2.2 Which values are normal?
Blood pressure is too high if at rest, the diastolic pressure is
above 90 mmHg and/or the systolic blood-pressure is over 160
mmHg. In this case, please consult your doctor immediately.
Directions For Use 3
Long-term values at this level endanger your health due to the
associated advancing damage to the blood vessels in your body.
Should the systolic blood-pressure values lie between 140
mmHg and 160 mmHg and/or the diastolic blood-pressure values
lie between 90 mmHg and 95 mmHg, please consult your doctor.
Furthermore, regular self-checks will be necessary.
With blood-pressure values that are too low, i.e. systolic values
under 105 mmHg and/or diastolic values under 60 mmHg, please
consult your doctor.
Even with normal blood-pressure values, a regular self-check with
your blood-pressure monitor is recommended. In this way you
can detect possible changes in your values early and react
appropriately.
If you are undergoing medical treatment to control your blood
pressure, please keep a record of the level of your blood pressure
by carrying out regular self-measurements at specific times of
the day. Show these values to your doctor. Never use the
results of your measurements to alter independently the
drug doses prescribed by your doctor.
Table for classifying blood-pressure values (units mmHg)
according to World Health Organization:
Range Systolic
Blood-
pressure
Diastolic
Blood-
pressure
Measures
Normal 105-129 60-84 Self-check
High normal 130-139 85-89 Self-check
Hypertension
Stage 1 (Mild)
140-159 90-99 Consult your doctor
Hypertension
Stage 2 (Moderate)
160-179 100-109 Consult your doctor
immediately
Hypertension
Stage 3 (Severe)
180-209 110-119 Consult your doctor
immediately
Hypertension
Stage 4 (Very Severe)
>210 >120 Consult your doctor
immediately
4 Wrist Watch Blood Pressure Monitor Welch Allyn
Further information
If your values are mostly standard under resting conditions
but exceptionally high under conditions of physical or
psychological stress, it is possible that you are suffering from
«labile hypertension». Please consult your doctor if you
suspect that this might be the case.
Correctly measured diastolic blood-pressure values above
120 mmHg require immediate medical treatment.
2.3. What can be done if regular increased/low
values are obtained?
1. Please consult your doctor.
2. Increased blood-pressure values (various forms of
hypertension) are associated long- and medium term with
considerable risks to health. This concerns the arterial blood
vessels of your body, which are endangered due to
constriction caused by deposits in the vessel walls
(Arteriosclerosis). A deficient supply of blood to important
organs (heart, brain, muscles) can be the result. Furthermore,
with long-term continuously increased blood-pressure
values, the heart will become structurally damaged.
3. There are many different causes of the appearance of high
blood pressure. We differentiate between the common
primary (essential) hypertension, and secondary
hypertension. The latter group can be ascribed to specific
organic malfunctions. Please consult your doctor for
information about the possible origins of your own increased
blood pressure values.
4. There are measures which you can take, not only for
reducing a medically established high blood pressure, but
also for prevention. These measures are part of your general
way of life:
Directions For Use 5
Eating habits
Strive for a normal weight corresponding to your age. Reduce
overweight!
Avoid excessive consumption of common salt.
Avoid fatty foods.
Previous illnesses
Follow consistently any medical instructions for treating
previous illness such as:
Diabetes (Diabetes Miletus)
Fat metabolism disorder
• Gout
Habits
Give up smoking completely
Drink only moderate amounts of alcohol
Restrict your caffeine consumption (Coffee)
Physical constitution:
After a preliminary medical examination, do regular sport.
Choose sports which require stamina and avoid those which
require strength.
Avoid reaching the limit of your performance.
With previous illnesses and/or an age of over 40 years,
please consult your doctor before beginning your sporting
activities. He will advise you regarding the type and extent of
types of sport that are possible for you.
3. The various components of the blood-
pressure monitor
The illustration shows the blood-pressure monitor, consisting of:
6 Wrist Watch Blood Pressure Monitor Welch Allyn
Wrist cuff Type WC1 13.5--19.5 cm, for wrist circumference of
13.5 to 19.5 cm
4. Putting the blood-pressure monitor
into operation
4.1. Inserting the batteries
After you have unpacked your device, first insert the batteries.
The battery compartment is located on the left lateral side of the
device (see illustration).
1. Remove cover as illustrated.
2. Insert the batteries (2 x size AAA 1.5V), observing the
indicated polarity.
3. If the battery warning appears in the display, the batteries are
empty and must be replaced by new ones.
126
85
76
LCD
Display
Battery
Cover
O/I Button
Wrist Cuff
126
85
76
Directions For Use 7
Attention!
After the battery warning appears, the device is blocked until
the batteries have been replaced.
Please use «AAA» Long-Life or Alkaline 1.5V Batteries. The
use of 1.2V Accumulators is not recommended.
If the blood-pressure monitor is left unused for long periods,
please remove the batteries from the device.
Functional check: Press and hold the O/I button to test all the
display elements. When functioning correctly all segments
appear for about 2 seconds (If the 0/l button is pressed and held
for up to 3 seconds, the last measured value will be displayed).
5. Carrying out a measurement
5.1. Before the measurement:
Avoid eating, smoking, as well as all forms of exertion
directly before the measurement. All these factors influence
the measurement result. Try and find time to relax by sitting
in an armchair in a quiet atmosphere for about ten minutes
before the measurement.
Always measure on the same wrist (normally left).
Attempt to carry out the measurements regularly at the
same time of day, since the blood-pressure changes during
the course of the day.
5.2. Common sources of error.
Note:
Comparable blood-pressure measurements always require the
same conditions! These are always quiet conditions.
All efforts by the patient to support the arm can increase the
blood-pressure. Make sure you are in a comfortable, relaxed
position and do not activate any of the muscles in the
8 Wrist Watch Blood Pressure Monitor Welch Allyn
measurement arm during the measurement. Use a cushion
for support if necessary.
If the wrist artery lies considerably lower (higher) than the
heart, an erroneously higher (lower) blood-pressure will be
measured! (Each 15 cm difference in height results in a
measurement error of 10 mmHg!)
A loose cuff causes false measurement values.
With repeated measurements, blood accumulates in the
respective arm, which can lead to false results. Correctly
executed blood-pressure measurements should therefore
first be repeated after a 5 minute pause or after the arm has
been held up in order to allow the accumulated blood to flow
away (after at least 3 minutes).
5.3. Fitting the cuff
1. Remove all objects and
jewellery (e.g. wristwatch)
from the wrist in question.
2. Draw the cuff over the wrist.
3. The distance between the
cuff and the hand should be
approximately 10 mm.
4. Secure the cuff with the
Velcro fastener, so that it lies
comfortably and not too tight
whereby no space should remain between the cuff and the
wrist.
5. Lay the arm on a table, with the palm upwards. Support the
arm with a rest (cushion), so that the cuff rests at about the
same height as the heart. Take care, that the cuff lies free.
Remain so for 2 minutes sitting quietly, before beginning
with the measurement.
126
85
76
0.5 - 1.0 cm
1/4" - 1/2"
Directions For Use 9
5.4. Measuring procedure
After the cuff has been appropriately positioned, the
measurement can begin:
1. Press the O/l-button, the pump
begins to inflate the cuff. In the
display, the increasing cuff-
pressure is continually displayed.
2. After reaching the inflation
pressure, the pump stops and the pressure
slowly falls away. The cuff-pressure (large
characters) is displayed during the
measurement. When the device has detected
the pulse, the heart symbol in the display
begins to blink and a beep tone is audible for
every pulse beat.
3. When the measurement has been concluded,
a long beep tone sounds. The measured
systolic and diastolic blood-pressure values as
well as the pulse frequency are now displayed.
Example (Fig.): Systole 118, Diastole 73, Pulse 75
The measurement results are displayed, until you
switch the device off. If no button is pressed for 5 minutes, the
device switches automatically off, to save the batteries.
10 Wrist Watch Blood Pressure Monitor Welch Allyn
5.5. Discontinuing a measurement
If it is necessary to interrupt a blood pressure
measurement for any reason (e.g. the patient
feels unwell), the O/l button can be pressed at
any time. The device then immediately lowers
the cuff-pressure automatically.
5.6. Memory - storage and recall of the
measurements
The blood-pressure monitor
automatically stores the last
measurement value. By pressing the
O/l button (when the power is off) for up
to 3 seconds, the last measurement can
be displayed.
Further information
Measurements should not occur soon after each other, since the
results will be falsified. Wait for several minutes in a relaxed
position, sitting or lying, before you repeat a measurement.
6. Error messages/malfunctions
If an error occurs during a measurement, the
measurement is discontinued and a
corresponding error code is displayed (Example:
Error No. 2).
Error
Number
Possible Cause(s)
Error 1 No pulse has been detected.
Error 2 Unnatural pressure impulses influence the measurement result.
Reason: The arm was moved during the Measurement (Artifact).
Directions For Use 11
Other possible malfunctions and their elimination
If problems occur when using the device, the following points
should be checked and if necessary, the corresponding measures
are to be taken:
Further Information
The level of blood-pressure is subject to fluctuations even with
healthy people. Comparable measurements always require
the same conditions (Quiet conditions)!
If, in spite of observing all these factors, the fluctuations are
larger than 15 mmHg, and/or you hear irregular pulse tones on
several occasions, please consult your doctor.
This device has been subjected to strict clinical tests. The
conformity of this product with the requirements of the CE-
Error 3 The inflation of the cuff takes too long. The cuff is not correctly seated.
Malfunction Remedy
The display remains empty when
the instrument is switched on
although the batteries are in
place.
1. Check batteries for correct polarity and , if
necessary, insert correctly.
2. If the display is unusual, re-insert batteries
or exchange them.
The device frequently fails to
measure the blood pressure
values, or the values measured
are too low (too high).
1. Check the positioning of the cuff.
2. Measure the blood-pressure again in peace
and quiet under observance of the details
made in point 5.
Every measurement results in
different values, although the
device functions normally and
normal values are displayed.
Please pay attention to the following
information as well as the points listed under
«Common Sources of Error» and repeat the
measurement.
The blood pressure values
measured differ from those
measured by the doctor.
Record the daily development of the values
and consult your doctor about them.
Error
Number
Possible Cause(s)
12 Wrist Watch Blood Pressure Monitor Welch Allyn
guideline 93/42 EWG, council from June 14, 1993 concerning
Medical products and Medical-Product-Legislation from August
2, 1994, was established through a conformity check process.
You must consult your dealer if there are technical problems with
the blood-pressure instrument. Never attempt to repair the
instrument yourself!
Any unauthorized opening of the instrument invalidates all
guarantee claims!
7. Care and maintenance, recalibration
a. Do not expose the device to extreme
temperatures, humidity, dust, or direct
sunlight.
b. The cuff contains a sensitive air-tight
bubble. Handle this carefully and avoid all
types of straining through twisting or
buckling.
c. Clean the device with a soft, dry cloth.
Do not use petrol, thinners, or similar
solvent. Spots on the cuff can be
removed carefully with a damp cloth
and soapsuds. The cuff must not be
washed!
d. Do not drop the instrument or treat it
roughly in any way. Avoid strong vibrations.
e. Never open the device! Otherwise the
manufacturer calibration becomes invalid!
Periodical recalibration
Sensitive measuring devices must from time to
time be checked for accuracy. We recommend
126
85
76
126
85
76
126
85
76
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104

Welch Allyn OSZ 3 Easy Directions For Use Manual