1 General.................................................................................................................... 4
1.1 Copyright © YASKAWA Europe GmbH............................................................ 4
1.2 About this manual............................................................................................. 5
1.3 Safety information............................................................................................. 6
2 Hardware description............................................................................................. 7
2.1 Safety information for users.............................................................................. 7
2.2 Properties......................................................................................................... 8
2.3 Structure........................................................................................................... 9
2.3.1 Overview........................................................................................................ 9
2.3.2 Interfaces..................................................................................................... 10
2.3.3 Memory management.................................................................................. 11
2.4 Dimensions..................................................................................................... 12
2.5 General data................................................................................................... 13
2.6 Use in difficult operating conditions................................................................ 14
2.7 Technical data................................................................................................. 15
3 Deployment........................................................................................................... 18
3.1 Installation...................................................................................................... 18
3.2 Commissioning............................................................................................... 19
3.2.1 Firmware update.......................................................................................... 20
3.2.2 Startup-Manager.......................................................................................... 22
3.3 Connection to a PLC system.......................................................................... 25
3.4 Operating system Windows Embedded Compact 7....................................... 26
3.4.1 General........................................................................................................ 26
3.4.2 Structure...................................................................................................... 27
3.5 Integrated server............................................................................................ 30
3.5.1 General........................................................................................................ 30
3.5.2 ftp server...................................................................................................... 30
3.5.3 Telnet server................................................................................................ 31
3.5.4 VNC server.................................................................................................. 33
3.5.5 Web server.................................................................................................. 34
3.6 Access to the network resources.................................................................... 35
4 Industrial Security and Installation guidelines.................................................. 37
4.1 Industrial security in information technology................................................... 37
4.1.1 Protection of hardware and applications..................................................... 38
4.1.2 Protection of PC-based software................................................................. 39
4.2 Installation guidelines..................................................................................... 39
4.2.1 Basic rules for the EMC-equitable assembly of installations....................... 39
4.2.2 EMC-equitable assembly............................................................................. 43
4.2.3 EMC-equitable cabling................................................................................ 44
4.2.4 Special precautions providing high noise immunity..................................... 47
4.2.5 Checklist for the EMC-compliant installation of controllers.......................... 48
Appendix............................................................................................................... 49
A History of changes............................................................................................ 51
HMI Table of contents
HB160 | TP-smart | H71-71A41-0 | en | 23-10 3
1 General
1.1 Copyright © YASKAWA Europe GmbH
This document contains proprietary information of Yaskawa and is not to be disclosed or
used except in accordance with applicable agreements.
This material is protected by copyright laws. It may not be reproduced, distributed, or
altered in any fashion by any entity (either internal or external to Yaskawa) except in
accordance with applicable agreements, contracts or licensing, without the express
written consent of Yaskawa and the business management owner of the material.
For permission to reproduce or distribute, please contact: YASKAWA Europe GmbH,
European Headquarters, Philipp-Reis-Str. 6, 65795 Hattersheim, Germany
Tel.: +49 6196 569 300
Fax.: +49 6196 569 398
Internet: www.yaskawa.eu.com
Hereby, YASKAWA Europe GmbH declares that the products and systems are in compli-
ance with the essential requirements and other relevant provisions. Conformity is indi-
cated by the CE marking affixed to the product.
For more information regarding CE marking and Declaration of Conformity (DoC), please
contact your local representative of YASKAWA Europe GmbH.
SPEED7 is a registered trademark of YASKAWA Europe GmbH.
All Microsoft Windows, Office and Server products mentioned are registered trademarks
of Microsoft Inc., USA.
Portable Document Format (PDF) is a registered trademark of Adobe Systems, Inc.
All other trademarks, logos and service or product marks specified herein are owned by
their respective companies.
Every effort has been made to ensure that the information contained in this document
was complete and accurate at the time of publishing. We cannot guarantee that the infor-
mation is free of errors, and we reserve the right to change the information at any time.
There is no obligation to inform the customer about any changes. The customer is
requested to actively keep his documents up to date. The customer is always responsible
for the deployment of the products with the associated documentation, taking into
account the applicable directives and standards.
This documentation describes all hardware and software units and functions known
today. It is possible that units are described that do not exist at the customer. The exact
scope of delivery is described in the respective purchase contract.
Contact your local representative of YASKAWA Europe GmbH if you have errors or ques-
tions regarding the content of this document. You can reach YASKAWA Europe GmbH via
the following contact:
All Rights Reserved
EC conformity declaration
Conformity Information
Trademarks
General terms of use
Document support
HMI
General
Copyright © YASKAWA Europe GmbH
HB160 | TP-smart | H71-71A41-0 | en | 23-10 4
Contact your local representative of YASKAWA Europe GmbH if you encounter problems
or have questions regarding the product. If such a location is not available, you can reach
the Yaskawa customer service via the following contact:
YASKAWA Europe GmbH,
European Headquarters, Philipp-Reis-Str. 6, 65795 Hattersheim, Germany
Tel.: +49 6196 569 500 (hotline)
1.2 About this manual
This manual describes the smartPanel H71-71A410-0.
nIt contains a description of the structure, project engineering and deployment.
nThe manual is written for users with basic knowledge of automation technology.
nThe manual consists of chapters. Each chapter describes a completed topic.
nThe following guides are available in the manual:
An overall table of contents at the beginning of the manual.
References with pages numbers.
Validity of the documentation
Product Order no. as of version:
TP 307-SM H71-71A410-0 HW: 01 FW: V1.0.4
Important passages in the text are highlighted by following icons and headings:
DANGER!
Immediate or likely danger. Personal injury is possible.
CAUTION!
Damages to property is likely if these warnings are not heeded.
Supplementary information and useful tips.
Technical support
Objective and contents
Icons Headings
HMI General
About this manual
HB160 | TP-smart | H71-71A41-0 | en | 23-10 5
1.3 Safety information
The system is constructed and produced for:
ncommunication and process control
ngeneral control and automation tasks
nindustrial applications
noperation within the environmental conditions specified in the technical data
ninstallation into a cubicle
DANGER!
This device is not certified for applications in
in explosive environments (EX-zone)
The manual must be available to all personnel in the
nproject design department
ninstallation department
ncommissioning
noperation
CAUTION!
The following conditions must be met before using or commis-
sioning the components described in this manual:
Hardware modifications to the process control system should only be
carried out when the system has been disconnected from power!
Installation and hardware modifications only by properly trained per-
sonnel.
The national rules and regulations of the respective country must be
satisfied (installation, safety, EMC ...)
National rules and regulations apply to the disposal of the unit!
Applications conforming
with specifications
Documentation
Disposal
HMI
General
Safety information
HB160 | TP-smart | H71-71A41-0 | en | 23-10 6
2 Hardware description
2.1 Safety information for users
The modules make use of highly integrated components in MOS-Technology. These com-
ponents are extremely sensitive to over-voltages that can occur during electrostatic dis-
charges. The following symbol is attached to modules that can be destroyed by electro-
static discharges.
The Symbol is located on the module, the module rack or on packing material and it indi-
cates the presence of electrostatic sensitive equipment. It is possible that electrostatic
sensitive equipment is destroyed by energies and voltages that are far less than the
human threshold of perception. These voltages can occur where persons do not dis-
charge themselves before handling electrostatic sensitive modules and they can damage
components thereby, causing the module to become inoperable or unusable. Modules
that have been damaged by electrostatic discharges can fail after a temperature change,
mechanical shock or changes in the electrical load. Only the consequent implementation
of protection devices and meticulous attention to the applicable rules and regulations for
handling the respective equipment can prevent failures of electrostatic sensitive modules.
Modules must be shipped in the original packing material.
When you are conducting measurements on electrostatic sensitive modules you should
take the following precautions:
nFloating instruments must be discharged before use.
nInstruments must be grounded.
Modifying electrostatic sensitive modules you should only use soldering irons with
grounded tips.
CAUTION!
Personnel and instruments should be grounded when working on electro-
static sensitive modules.
Handling of electrostatic
sensitive modules
Shipping of modules
Measurements and altera-
tions on electrostatic sen-
sitive modules
HMI Hardware description
Safety information for users
HB160 | TP-smart | H71-71A41-0 | en | 23-10 7
2.2 Properties
The smartPanel allows you to visualize and alter operating states and recent process
values of a connected PLC. The smartPanel is a compact and modular embedded PC
based on WindowsÒ EC 7. Besides the extensive WindowsÒ CE functions the smartPanel
offers varied communication possibilities. Here the smartPanel can simply be configured,
controlled and remoted. By including a selectable HMI/SCADA runtime the smartPanel is
particularly suitable for monitoring and controlling of process cycles.
nWindowsÒ Embedded Compact 7
nMovicon 11 CE Standard (4096 I/O Bytes)
nProcessor ARM Cortex A8 1GHz
nFlash memory 4GB, RAM 512MB DDR
nRS232/RS422/RS485, USB-A and Ethernet interface
nRobust plastic case
nDisplay resolution 480 x 800 / 800 x 480, 64K colors
nClock back up (Goldcap)
nResistive analog touch screen
nEasy mounting via mounting clips
nProtection class IP66, Type 2 and 4X (Front) / IP20 (Back)
Order data
Type Order number Description
TP 307-SM H71-71A410-0 7'' TFT color, RS232/RS422/RS485, USB-A, Ethernet RJ45
General
HMI
Hardware description
Properties
HB160 | TP-smart | H71-71A41-0 | en | 23-10 8
2.3 Structure
2.3.1 Overview
1 Interfaces
2 Display with touch sensitive area (Touch-Screen)
1 USB-A interface USB 2.0
2 RJ45 jack for Ethernet communication LAN
3 RS232/RS422/RS485 interface COM
4 Slot for DC 24V voltage supply
Front view
Bottom view
HMI Hardware description
Structure > Overview
HB160 | TP-smart | H71-71A41-0 | en | 23-10 9
2.3.2 Interfaces
Using the "Host"-USB-A interface USB mouse, keyboard, stick or USB hard discs can be
connected.
The RJ45 jack provides the interface to the twisted pair cable, required for Ethernet. The
Ethernet interface has got two LEDs for status display.
LEDs
green yellow
Description
on off no link
blinks on 100Mbit/s link
blinks off 10Mbit/s link
9 pin SubD plug
nInterface is compatible to the COM interface of a PC
nLogical signals as voltage levels
nPoint-to-point links with serial full-duplex transfer in two-wire technology up to 15m
distance
nData transfer rate up to 115.2kbit/s
"Host"-USB-A
Ethernet connection
RS232 interface
HMI
Hardware description
Structure > Interfaces
HB160 | TP-smart | H71-71A41-0 | en | 23-10 10
9 pin SubD jack
nLogical states represented by voltage differences between the 4 cores
nSerial bus connection in 4-wire technology using full duplex mode
nData communications up to a max. distance of 500m
nData communication rate up to 115.2kBaud
nSerial bus connection in 2-wire technology using half duplex mode
The smartPanel has got an integrated power supply. The power supply has to be pro-
vided with DC 24V (18 ... 32 VDC). For this you find an according DC 24V slot at the
bottom
Ä
‘Connect power supply’ page 18.
2.3.3 Memory management
The following memory systems are available for the smartPanel:
n512MB work memory (RAM)
n4GB user memory (Flash)
nUSB storage media using "Host"-USB-A interface
Every Touch Panel has a work memory with a size of 512MB. The work memory is not
buffered and is deleted after shut down. Please regard that also registry entries are
stored in the work memory that are set back to default settings after the next re-boot.
As internal permanent storage medium every smartPanel has a flash disk with a size of
4GB. 2GB of this is available to the user. After the start of WindowsÒ this memory is listed
as Flashdisk under My Device.
RS422/485 interface
Power supply
Overview
Work memory (RAM)
User memory (Flash)
HMI Hardware description
Structure > Memory management
HB160 | TP-smart | H71-71A41-0 | en | 23-10 11
The connection of USB sticks and USB drives by use of the "Host"-USB-A interface is
supported by the smartPanel. After connection the storage media is listed as USB Hard
Disk under My Device.
2.4 Dimensions
Front panel (L x H) 187 x 147 mm
Depth (D+T) 29 + 5 mm
Installation cutting (A x B) 176 x 136 mm
The degrees of protection are only guaranteed when the following is
observed:
Material thickness at the mounting cut-out: 1.5 ... 6mm
The deviation from the plane for the panel cut-out is
£
0.5mm. This
condition must be fulfilled for the mounted HMI device.
Permissible surface roughness in the area of the seal:
£
120µm (fric-
tion coefficient 120)
USB storage media
(USB 2.0)
Installation dimensions
HMI
Hardware description
Dimensions
HB160 | TP-smart | H71-71A41-0 | en | 23-10 12
2.5 General data
Conformity and approval
Conformity
CE 2014/30/EU EMC directive
Approval
UL Refer to Technical data
others
RoHS 2011/65/EU Restriction of the use of certain hazardous substances in
electrical and electronic equipment
Protection of persons and device protection
Type of protection - Rear: IP20; Front: IP66, NEMA Type 2 and Type 4x
Electrical isolation
to the field bus - electrically isolated
to the process level - electrically isolated
Insulation resistance -
Insulation voltage to reference earth
Inputs / outputs - AC / DC 50V, test voltage AC 500V
Protective measures - against short circuit
Environmental conditions to EN 61131-2
Climatic
Storage / transport EN 60068-2-14 -20…+70°C
Operation
Horizontal installation EN 61131-2 0…+40°C
Vertical installation EN 61131-2 0…+50°C
Air humidity EN 60068-2-30 RH1 (without condensation, rel. humidity 5…85%)
Pollution EN 61131-2 Degree of pollution 2
Mechanical
Oscillation EN 60068-2-6 1g, 9Hz ... 150Hz
Shock EN 60068-2-27 15g, 11ms
Mounting conditions
Mounting place - In the control cabinet
Mounting position - Horizontal and vertical
HMI Hardware description
General data
HB160 | TP-smart | H71-71A41-0 | en | 23-10 13
EMC Standard Comment
Emitted interference EN 61000-6-4 Class A (Industrial area)
Noise immunity
zone B
EN 61000-6-2 Industrial area
EN 61000-4-2 ESD
8kV at air discharge (degree of severity 3),
4kV at contact discharge (degree of severity 2)
EN 61000-4-3 HF field immunity (casing)
80MHz … 1000MHz, 10V/m, 80% AM (1kHz)
1.4GHz ... 2.0GHz, 3V/m, 80% AM (1kHz)
2GHz ... 2.7GHz, 1V/m, 80% AM (1kHz)
EN 61000-4-6 HF conducted
150kHz … 80MHz, 10V, 80% AM (1kHz)
EN 61000-4-4 Burst, degree of severity 3
EN 61000-4-5 Surge, degree of severity 31
1) Due to the high-energetic single pulses with Surge an appropriate external protective circuit with lightning protection elements like conductors for lightning and overvoltage is
necessary.
2.6 Use in difficult operating conditions
Without additional protective measures, the products must not be used in
locations with difficult operating conditions; e.g. due to:
dust generation
chemically active substances (corrosive vapors or gases)
strong electric or magnetic fields
HMI
Hardware description
Use in difficult operating conditions
HB160 | TP-smart | H71-71A41-0 | en | 23-10 14
2.7 Technical data
Order no. H71-71A41-0
Type smartPanel TP307-SM
Display
Display size (diagonal) 7 "
Display size (width) 155 mm
Display size (height) 88 mm
Resolution 480 x 800 / 800 x 480
Aspect ratio 16:9
Type of display TFT color (64K colors)
MTBF Backlights (25°C) 20000 h
System properties
Processor Cortex-A8 1000 MHz
Operating system Windows embedded Compact 7
User software Movicon 11 CE Standard
Work memory 512 MB
User memory 4 GB
Available memory (user data) 2 GB
SD/MMC Slot -
CF Card Slot Typ II -
CFast Slot -
Time
Real-time clock buffered ü
Clock buffered period (min.) 2 w
Type of buffering Goldcap
Load time for 50% buffering period 5 h
Load time for 100% buffering period 10 h
Accuracy (max. deviation per day) 8 s
Operating controls
Touchscreen resistive
Touch function Single Touch
Keyboard external via USB
Mouse external via USB
Interfaces
MPI, PROFIBUS-DP -
MPI, PROFIBUS-DP connector -
Serial, COM1 RS232 / RS422 / RS485
HMI Hardware description
Technical data
HB160 | TP-smart | H71-71A41-0 | en | 23-10 15
Order no. H71-71A41-0
COM1 connector Sub-D, 9-pin, male
Serial, COM2 -
COM2 connector -
Number of USB-A interfaces 1
USB-A connector USB-A (host)
Number of USB-B interfaces -
USB-B connector -
Number of ethernet interfaces 1
Ethernet Ethernet 10/100 MBit
Ethernet connector RJ45
Integrated ethernet switch -
Video connectors -
Audio connections -
Technical data power supply
Power supply (rated value) DC 24 V
Power supply (permitted range) 18 - 32 VDC
Reverse polarity protection ü
Current consumption (no-load operation) 0.1 A
Current consumption (rated value) 0.3 A
Inrush current 38 A
I²t 0.33 A²s
Power loss 7 W
Status information, alarms, diagnostics
Supply voltage display none
Mechanical data
Housing / Protection class
Material PC + ABS
Mounting mounting clips
Protection class IP front side IP 66
Protection class IP back side IP 20
Protection class NEMA front side Type 2, 4X
Protection class NEMA back side -
Dimensions
Front panel 187 mm x 147 mm x 5 mm
Rear panel 172 mm x 133 mm x 29 mm
Installation cut-out
HMI
Hardware description
Technical data
HB160 | TP-smart | H71-71A41-0 | en | 23-10 16
Order no. H71-71A41-0
Width 176 mm
Height 136 mm
Minimum 1.5 mm
Maximum front panel thickness 6 mm
Net weight 500 g
Weight including accessories 631 g
Gross weight 900 g
Environmental conditions
Operating temperature 0 °C to 50 °C
Storage temperature -20 °C to 70 °C
Certifications
UL certification yes
KC certification -
HMI Hardware description
Technical data
HB160 | TP-smart | H71-71A41-0 | en | 23-10 17
3 Deployment
3.1 Installation
The smartPanel is suitable for the installation in operating tables and control cabinet
fronts. The installation happens via the backside. The smartPanel is provided with a fixing
technique that allows an easy connection with a crosstip screwdriver. A fast and easy
device change is possible.
For the installation into a operating tableau and control cabinet fronts, the smartPanel
requires the following front plate cutting:
smartPanel A x B in mm
H71-71A410-0 176 x 136 mm
To fix the smartPanel mounting clips are included. For the installation a small crosstip
screwdriver is required.
1. Push the smartPanel [3] from the front side into the front panel cutting [1] until it
touches the panel with the seal [2].
2. Put the mounting clips [4] on all four sides of the smartPanel into the openings. The
screws should point in the direction of the front panel.
3. Screw the screws from the other side with the crosstip screwdriver [5].
nFor the cabling of the DC 24V power supply (18 ... 32 VDC) a black plug is included.
The connector is a plug with screw contacts. The associated label is located on the
back of the smartPanel.
nThe smartPanel must always be grounded to earth. Grounding helps limit the effects
of noise due to electromagnetic interference.
nUse the power supply terminal marked with for grounding.
nThe power supply circuit may be floating or grounded. In the latter case, connect to
the ground the power supply as shown in figure with a dashed line.
nWhen using the floating power scheme, note that the smartPanel internally connects
the power to the ground with a 1MΩ resistor in parallel with a 4.7nF capacitor.
Overview
Installation cutting
Installation
Connect power supply
HMI
Deployment
Installation
HB160 | TP-smart | H71-71A41-0 | en | 23-10 18
3.2 Commissioning
CAUTION!
Before commissioning the device must be brought to room tempera-
ture.
At condensation the device must be absolutely dry before connected
to power.
To avoid overheat during operation the device must not be laid open
to direct sun light.
After opening the control cabinet or desk, there are parts with pos-
sible dangerous voltage available.
For all signal connections only screened cables are permitted.
Signal cables must not be let within the same cable shaft as high
voltage cables.
CAUTION!
When changing the ‘Regional Settings’ , please note that only English
and German are supported, other languages can lead to a system crash.
HMI Deployment
Commissioning
HB160 | TP-smart | H71-71A41-0 | en | 23-10 19
3.2.1 Firmware update
To execute the firmware update an empty USB stick (at least 1GB) in FAT32 format is
necessary.
The latest firmware versions can be found in the Download Center at
www.yaskawa.eu.com.
CAUTION!
When installing a new firmware you have to be extremely careful. Under
certain circumstances you can destroy the smartPanel, for example if the
voltage supply is interrupted during transfer or if the firmware file is defec-
tive. In this case, please call our hotline!
Please regard that the version of the update firmware has to be different
from the existing firmware otherwise no update is executed.
1. Go to Download Center at www.yaskawa.eu.com.
2. Under Firmware H71-71A410-0 download the ZIP file for the update process and
unzip the content in the root directory of the USB stick.
1. Connect the smartPanel to the power supply.
ðThe smartPanel starts with the Startup-Manager.
2. There is a button on the initial screen with a counter, which counts backwards. If
you click on [Main] within this time, you will get to the selection menu.
ðYou are now on the WindowsÒ screen.
3. Open "System Tools" via ‘Start è Programs è Tools’.
Requirement
Current firmware on
www.yaskawa.eu.com
Load firmware on USB
stick
Prepare the smartPanel
HMI
Deployment
Commissioning > Firmware update
HB160 | TP-smart | H71-71A41-0 | en | 23-10 20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51

VIPA smartPanel TP 107-SM Manuale del proprietario

Tipo
Manuale del proprietario

in altre lingue