en
3
Note to the user
Any complaints, problems, or safety concerns should be reported to the manufacturer or the distributor.
In the European Union (according to Regulation (EU) 2017/745 on medical devices) any serious incidents occurring in rela-
tion with the product must be reported to the manufacturer and the competent authorities in the Member State in which the
user resides.
Risk due to contamination / infection
• To prevent contamination of your breast milk, thoroughly wash your hands with soap and water before each use.
• Only use original Ardo pumpsets. If parts from other manufacturers are used, there is a risk of microbial contamination of
parts as well as the breast milk because the parts are not compatible.
Risk of health problems and serious injuries
• This device must not be used during pregnancy because expressing breast milk can start contractions.
• Do not use this device while driving a car (even as a passenger).
• Do not use this breastpump if you are overtired and may fall asleep during use, because this may lead to irritation of the
nipples.
• Make sure that this device is not used unsupervised by children or by people with reduced mental capabilities.
Ardo Bellis may only be used for the purposes described in Chapter 3. For all uses apart from the intended use, all warranty
and liability claims against the manufacturer are excluded.
Risk of an electric shock
• The Ardo Bellis breastpump with the power adapter is only suitable for use indoors. Do not use outdoors.
• Only use this breastpump with the supplied Ardo original USB cable and power adapter.
• Ensure that the power adapter can always be easily accessed.
• Ardo Bellis is not waterproof.
- The device must therefore not be immersed in water or other liquids nor used or stored in locations where it could
fall into water.
- Do not use in the bath or when showering.
- Do not clean in the dishwasher, under running water, or by immersing in water.
- The pump unit must not be used if it has fallen into water or is wet. If this happens, contact your service partner or
the manufacturer!
• This breastpump must not be opened or modified in any way without the permission of the manufacturer. It does not
contain any parts that are maintained by the user.
• Handle this device with care and avoid all shocks, blows, or vibrations (e.g., do not allow it to drop onto the floor). If this
device is nevertheless exposed to one of the mechanical effects described above, carefully inspect the device for damage
before the next use. If the device is damaged, contact the point of sale, the hire center or the customer service team at
Ardo medical AG.
Risk of fire or toxic vapors
Keep the pump unit, USB cable with power adapter, and accessories away from sources of heat.