On the packaging, on the type plate of the monitor and in the User’s
Manual you may encounter the following symbols and abbreviations
shown here with their meaning:
Use by/Expiry date
Lot number
For in vitro diagnostic use
This product fulfills the requirement of Directive 98/79/EC
on in vitro diagnostic medical devices.
Catalogue number
Please consult instructions for use
Caution (refer to accompanying documents). Please refer
to safety-related notes in the manual accompanying this
instrument.
Manufacturer
Store at
LOT
IVD
0088
ccxs_user_EN.book Seite 2 Montag, 11. Juli 2005 7:11 19
The CoaguChek XS System
3
English
The CoaguChek XS System
The CoaguChek XS System is used for quantitative monitoring of coagu-
lation values (common terms: thromboplastin time, PT, Quick value) with
CoaguChek XS PT test strips.
Self-monitoring and self-adjustment of oral coagulation therapy using
coagulation values determined with the aid of the CoaguChek XS System
may only be undertaken after consultation with your doctor and compre-
hensive instruction by a qualified healthcare professional. Your pharma-
cist / specialist supplier can provide you the training and/or put you in
touch with associations or institutions offering training in coagulation
self-monitoring. Please read the special notes on INR self-monitoring in
the package insert accompanying the test strips.
Please note
: This manual contains all the information you need to
operate and care for the CoaguChek XS System. Please
read this entire
manual carefully
before you use the monitor.
Last update user information: June 2005
ccxs_user_EN.book Seite 3 Montag, 11. Juli 2005 7:11 19
The CoaguChek XS System
4
ccxs_user_EN.book Seite 4 Montag, 11. Juli 2005 7:11 19
5
English
The CoaguChek XS System 3
Introduction 9
The CoaguChek XS System ............................................................ 9
Test principle ...................................................................................... 10
Contents of the pack ....................................................................... 10
Operating conditions ....................................................................... 11
Quality control .................................................................................... 12
About this manual
13
Manual format .................................................................................... 13
The CoaguChek XS monitor 16
Monitor guide ..................................................................................... 17
Batteries ................................................................................................ 18
Starting up
19
Inserting the batteries ..................................................................... 20
Code chip
23
Inserting the code chip ................................................................... 24
Monitor setup
26
Settings summary ............................................................................. 27
Setting up the monitor (Set Mode) ............................................ 28
Setting the date format ................................................................... 31
Setting the date ................................................................................. 32
Setting the time format ................................................................... 34
Setting the time ................................................................................. 35
Selecting the unit .............................................................................. 36
Setting the beep tone ...................................................................... 37
Setting the therapeutic range (INR) .......................................... 38
ccxs_user_EN.book Seite 5 Montag, 11. Juli 2005 7:11 19
6
Testing a capillary blood sample
43
Important notes ................................................................................. 44
Getting a good capillary blood sample .................................... 46
Testing by healthcare professionals .......................................... 47
Preparing to test ............................................................................... 48
Performing a test .............................................................................. 49
Disposal by healthcare professionals ....................................... 59
Notes concerning the display of results .................................. 60
Memory
63
Viewing test results ......................................................................... 63
Erasing memory ................................................................................ 66
Cleaning
69
Cleaning the plastic housing ....................................................... 69
Cleaning the test strip guide ........................................................ 70
Cleaning by healthcare professionals ...................................... 72
Error messages
73
Error messages overview ............................................................... 74
Error messages after turning the monitor on ........................ 76
Error messages when preparing to test ................................... 78
Error messages after the code number is confirmed ......... 82
Error messages during or after blood application ............... 84
Error message during infrared downloads ............................. 90
Display information and symbols
92
Further information 95
Ordering ............................................................................................... 95
Product limitations ........................................................................... 95
ccxs_user_EN.book Seite 6 Montag, 11. Juli 2005 7:11 19
7
English
Product specifications 96
Operating conditions and technical data ................................. 96
Sample material ................................................................................. 97
Storage and transport conditions ............................................... 97
Information service ........................................................................... 98
Repairs .................................................................................................. 98
Guarantee
99
Alphabetical index 100
ccxs_user_EN.book Seite 7 Montag, 11. Juli 2005 7:11 19
8
ccxs_user_EN.book Seite 8 Montag, 11. Juli 2005 7:11 19
Introduction
9
English
Introduction
The CoaguChek XS System
The CoaguChek XS System (CoaguChek XS monitor and CoaguChek XS
PT test strips) quantitatively determines prothrombin time (PT/Quick
value/INR) using capillary blood from a fingertip or untreated venous
whole blood. The CoaguChek XS System makes coagulation testing easy.
The CoaguChek XS monitor guides you through the test step by step
using the symbols in the display.
The code chip accompanying the test
strips contains lot-specific information about these test strips, including
calibration data that allow the correct results to be calculated, and the
expiry date for the test strips. You only need to insert the code chip, turn
the monitor on, insert the test strip, and apply a blood sample. When the
CoaguChek XS monitor is ready for a measurement, the result will be
displayed about 1 minute after application of the sample. After the meas-
urement, the monitor automatically stores the result in memory.
If you have any questions about the CoaguChek XS monitor, please con-
tact your local customer support and service centre. You will find contact
details on page 98.
Please note:
Before you use the monitor for the first time (i.e. after
you have first inserted the batteries), you must set the date and time
correctly to allow you to carry out measurements properly. Each time
you replace the batteries you need to check (and, if necessary adjust)
the date and time.
ccxs_user_EN.book Seite 9 Montag, 11. Juli 2005 7:11 19
Introduction
10
Test principle
The CoaguChek XS PT test strip contains a lyophilized reagent (reagent in
dried form). The reactive components of this reagent consist of thrombo-
plastin and a peptide substrate. When a sample is applied, thromboplas-
tin activates coagulation, which leads to the formation of thrombin. At the
same time the monitor starts to measure the time. The enzyme thrombin
cleaves the peptide substrate, generating an electrochemical signal.
Depending on the time elapsed when it first appears, this signal is then
converted by means of an algorithm into customary coagulation units
(INR, %Quick, seconds) and the result is displayed.
Contents of the pack
CoaguChek XS monitor
4 alkali-manganese batteries, 1.5 V, type AAA
CoaguChek Softclix lancing device with instructions for use
CoaguChek Softclix Lancet XL
System carry-case
User's Manual
ccxs_user_EN.book Seite 10 Montag, 11. Juli 2005 7:11 19
Introduction
11
English
Operating conditions
To ensure that your CoaguChek XS System functions properly, please
observe the following guidelines:
Only use the monitor at a room temperature between 18°C and 32°C.
Only use the monitor at a relative humidity between 10% and 85%.
When testing, place the monitor on a level, vibration-free surface or
hold it so it is roughly horizontal.
If the monitor is to remain unused for a longer period of time, keep it
in the carry-case supplied.
Use the monitor only up to a maximum altitude of 4300 metres.
Electromagnetic interference
Strong electromagnetic fields may interfere with the proper
operation of the monitor. Do not use the monitor near strong
electromagnetic fields.
ccxs_user_EN.book Seite 11 Montag, 11. Juli 2005 7:11 19
Introduction
12
Quality control
The CoaguChek XS System has a number of inbuilt quality-control
functions such as:
A check of the electronic components and functions every time the
monitor is turned on.
A check of the test strip temperature while a test is in progress.
A check of the expiry date and lot information on the test strip.
A quality control function is incorporated into the test strip. Quality
control and system checks using control test solutions that you may
be familiar with from other systems are no longer required.
ccxs_user_EN.book Seite 12 Montag, 11. Juli 2005 7:11 19
About this manual
13
English
About this manual
Manual format
The layout of this User’s Manual has been specially designed to help you
locate the most important information quickly and easily. Where illustra-
tions are used, they always appear on the left side of the page with the
accompanying explanation text on the right.
All instructions that require you to actively do something as well as
especially important information appear on a blue background.
This symbol draws attention to the possible risk of sustaining
injury or of damaging your health.
ccxs_user_EN.book Seite 13 Montag, 11. Juli 2005 7:11 19
About this manual
14
Example:
This column contains an illustra-
tion.
This column states what you
should do at this point.
1
Press the
On/Off
button.
ccxs_user_EN.book Seite 14 Montag, 11. Juli 2005 7:11 19
About this manual
15
English
Example:
This column contains an illustra-
tion of the display screen.
This column contains information
linked to the display screen.
Each time you turn on the moni-
tor, it runs a full display check,
briefly showing all the symbols
that might be displayed.
To prevent reading errors, check
regularly that all segments of the
symbols are showing.
code
pm
am
mem
error
set
%Q
Sec
QC C
INR
28:88 88
--
8888
888
18:88
ccxs_user_EN.book Seite 15 Montag, 11. Juli 2005 7:11 19
The CoaguChek XS monitor
16
The CoaguChek XS monitor
G
D
A
B
E
C
F
I
H
H
ccxs_user_EN.book Seite 16 Montag, 11. Juli 2005 7:11 19
The CoaguChek XS monitor
17
English
The CoaguChek XS monitor
A Display
Shows results, information,
symbols and results recalled
from memory.
B M (memory) button
Press this button to recall
results from memory and to
change the monitor settings.
You also press this button to
confirm the code number dis-
played before each test.
C On/Off button
Press this button to turn the
monitor on or off.
D Measurement chamber
cover
Remove this cover to clean
the test strip guide.
E Test strip guide
Insert the test strip here.
F Battery compartment
cover
Covers the battery compart-
ment (4 1.5 V alkali-manga-
nese batteries type AAA).
G Code chip slot
Insert the code chip here.
H Set button
Press this button to enter or
change the monitor settings.
I Infrared window
You can transfer data stored
in memory via this infrared
interface.
ccxs_user_EN.book Seite 17 Montag, 11. Juli 2005 7:11 19
The CoaguChek XS monitor
18
Batteries
To save power, the CoaguChek XS monitor automatically turns itself off
after 3 minutes unless a button has been pressed or a new test strip has
been inserted. When the monitor turns itself off, all results obtained up to
that point remain in memory. The monitor briefly indicates the battery
power level when it is turned on. The battery symbol is divided into four
segments which correspond to the battery power level.
Results are retained in memory together with the date and time even
when no batteries are inserted. All other settings are retained, too.
Think of the environment. Dispose of used batteries sensibly.
Do not throw batteries onto a fire. They may explode!
When replacing the batteries you must insert the new batteries within
one minute of removing the old ones, to keep the date and time set-
tings. If you take longer than this, you must re-enter the date and time.
Use only alkali-manganese batteries type AAA.
ccxs_user_EN.book Seite 18 Montag, 11. Juli 2005 7:11 19
Starting up
19
English
Starting up
Before using the monitor for the first time, carry out the following steps:
1 Insert the batteries
2 Insert the code chip (you can also carry out this step immediately
before testing)
3 Set the current date and time
4 Select the coagulation unit in which the results are to be displayed
ccxs_user_EN.book Seite 19 Montag, 11. Juli 2005 7:11 19
Starting up
20
Inserting the batteries
1
With the monitor turned off,
turn it over.
2
Gently press the tab on the
battery compartment cover
towards the centre of the
monitor and lift off the cover.
3
Insert the four batteries in the
battery compartment as indi-
cated. Pay attention to the
positions of “+” (top of bat-
tery) and “-” (flat end). Once
you have inserted the batter-
ies, the monitor turns itself on
after about 5 seconds.
Only use alkaline manganese
batteries (1.5 V, AAA). Think
of the environment. Dispose
of used batteries sensibly.
ccxs_user_EN.book Seite 20 Montag, 11. Juli 2005 7:11 19
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209

Roche CoaguChek XS System Manuale utente

Tipo
Manuale utente

in altre lingue