DS2400A QUICK GUIDE
DS2400A
General View: Laser Safety:
The scanner is classified as a Class 2 laser
product according to EN 60825-1 regulations
and as a Class II laser product according to
CDRH regulations.
Disconnect the power supply when opening the
device during maintenance or installation to
avoid exposure to hazardous laser light.
There is a safety device which allows the laser to
be switched on only if the motor is rotating above
the threshold for its correct scanning speed.
The motor and laser beam can be switched off
through a software command (see also the
WinHost Help On Line).
CAUTION-CLASS 3B LASER LIGHT
WHEN OPEN AVOID EXPOSURE TO BEAM
This product conforms to the applicable
requirements of 21CFR1040 at the date
of manufacture.
LASER LIGHT
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
MAX. OUTPUT RADIATION 1 mW
EMITTED WAVE LENGTH 630~680 nm
TO EN 60825-1:2001
R
CUS
218441
N246
8
Figure A
1
2
3
4 8
7
6
5
Power On / Data TX LED
External Trigger LED
Good Read LED
Laser On LED
Warning and Device Class Label
Laser Beam Output Window
A
ccessory Mounting Holes
Mounting Holes
For further details on product installation, see the
complete Reference Manual on the installation CD-ROM.
DS2400A can be configured through the WinHost
Windows-based software program available on the
installation CD-ROM.
For configuration it is necessary to create a cable
connecting the scanner to the PC as indicated in the
“How To Build A Simple Interface Test Cable” section of
this guide, otherwise you can use the C-Box 100.
Power Supply:
- This product is intended to be installed by Qualified
Personnel only.
- All Models:
This accessory device is intended to be supplied by a UL
Listed or CSA Certified Power Unit with «Class 2» or LPS
power source which supplies power directly to the
scanner via the 25-pin connector.
Warning and Device Class Labels
The laser diode used in this device is classified
as a class 3B laser product according to EN
60825-1 regulations and as a Class IIIb laser
product according to CDRH regulations. As it is
not possible to apply a classification label on
the laser diode used in this device, the following
label is reproduced below.
LASER LIGHT
AVOID EXPOSURE TO BEAM
CLASS 3B LASER PRODUCT
MAX. OUTPUT RADIATION 7 mW
EMITTED WAVE LENGTH 630~680 nm
TO EN 60825-1 (2001)
Laser Diode Class Label
Any violation of the optic parts in particular can
cause radiation up to the maximum level of the
laser diode (7 mW at 630 to 680 nm).
WEEE Compliance:
7
6
5
1
2
3
4
8
DS2400A QUICK GUIDE
2
Model Description:
DS2400A - X X X 0
Reading Range
0 = Short range
1 = Medium range
2 = Long range
Communication Interface
2 = RS232/RS485 main + RS232 aux
Optic Version
0 = Linear
1 = Raster
Reading Performance:
Version Reading Distance Max Code Resolution
mm (mils)
Speed
scans/s
0XX0 75 mm (3 in) - 340 mm (13.4 in) on 0.35 mm (14 mils) codes 0.20 (8) 600 to 1000
1XX0 100 mm (3.9 in) - 440 mm (17.3 in) on 0.50 mm (20 mils) codes 0.25 (10) 600 to 1000
2XX0 190 mm (7.5 in) - 600 mm (23.6 in) on 0.50 mm (20 mils) codes 0.35 (14) 600 to 1000
Technical Features:
ELECTRICAL FEATURES SOFTWARE FEATURES
Power Supply
10 –30 Vdc
Readable Codes
Power Consumption
5 W maximum
Main Serial Interface
Programmable:
RS232;
RS485 Full-Duplex/Half-
Duplex;
Auxiliary Interface
RS232
*
*
*
*
*
*
*
EAN/UPC
(including Add-on 2 and Add-on 5)
Code 39
2/5 Interleaved
Code 128
EAN 128
Codabar
Code 93
Baudrates
150 to 115200
* = ACB readable
ISBT 128
Inputs
Pharmacode
External Trigger
(optocoupled NPN or PNP)
Headers and
Up to four header and four
Voltage max.
30 Vdc
Terminators
terminator characters
Current Consumption
25 mA
Operating Modes
On-Line, Automatic,
max.
Serial-On-Line, Test
Outputs)
Configuration Modes
Through menus using:
OUT1, OUT2
(optocoupled)
WinHost utility
Host Mode (commands from
V
CE
max.
40 Vdc
one of the serial ports)
Collector Current
40 mA continuous;
Code Selection
Up to six different codes
max.
130 mA pulsed
during one reading phase
V
CE
Saturation
1V at 10 mA max.
Decoding Safety
Can enable multiple good
Power Dissipation
90 mW at 40 °C
reads of the same code
max.
(Ambient temp.)
Special Functions
ACB (Advanced Code Builder)
Motor Off
OPTICAL FEATURES Parameter Storage
Non-volatile internal EEPROM
Light Source
semiconductor laser diode
ENVIRONMENTAL FEATURES
Wavelength
In the range 630 to 680 nm
Operating
0° to +40 °C (+32° to +104 °F)
Safety Class
Class 2 - EN 60825-1; CDRH
Temperature
Storage
-20° to +70 °C (-4° to +158 °F)
USER INTERFACE Temperature
LED Indicators
Laser ON, Good Read,
Humidity max
90% non condensing
External Trigger,
Vibration Resistance
14 mm @ 2 to 10 Hz;
Data TX / Power ON IEC 68-2-6 test FC 1.5 mm @ 13 to 55 Hz;
2 G @ 70 to 200 Hz;
PHYSICAL FEATURES
2 hours on each axis
Dimensions
68x83.6x34 mm
(2.7x3.29x1.3 in)
Shock Resistance
30 G;
Weight
330 g.
(11.64 oz) IEC 68-2-27 test EA 11 ms; 3 shocks on each axis
Protection Class
IP65
DS2400A QUICK GUIDE
3
Accessories:
Name Description Part Number
GFC-2100 90° Reading Device 93A201000
GFC-2000 105° Reading Device 93A201080
OM2000 Oscillating Mirror 93A251031
INT-30 (for C-Box 100) 20 mA Current Loop Interface Board 93A151022
C-BOX 100/200 Connection Box 93ACC1510, 93ACC1520
C-BOX 300/310 Connection Box Profibus 93A301000, 93A301030
C-BOX 400/410 Connection Box DeviceNet 93A301010, 93A301040
MEP-542/543 Photocell Kit NPN/PNP 93ACC1727, 93ACC1728
Electrical Connections:
DS2400A is equipped with a cable terminated by a 25-pin female D-sub connector for connection to the power
supply, communication interface and input/output signals. You can bring system cables directly to the 25-pin
connector or you can connect the scanner directly to one of the various C-Box models and bring system wiring to
it (see the relative C-Box Installation Manual).
CAUTION
Do not connect GND and SGND to different (external) ground references. GND and SGND
are internally connected through filtering circuitry which can be permanently damaged if
subjected to voltage drops over 0.8 Vdc.
The details of the connector pins are indicated in the following table:
25-pin D-sub female connector pinout
Pin Name Function
13 VS Power supply input voltage +
25 GND Power supply input voltage -
1 CHASSIS Chassis Ground
9 VS External Trigger supply voltage +
18 EXT TRIG+ External Trigger +
19 EXT TRIG- External Trigger -
8 OUT1 + Output 1 +
11 OUT2 + Output 2 +
12, 22 OUT REF Output reference
20 RXAUX Auxiliary RS232
21 TXAUX Auxiliary RS232
23 CTSAUX Auxiliary handshake RS232
24 RTSAUX Auxiliary handshake RS232
6, 10, 14,
15, 16, 17
NC Not Connected
25-pin female connector
Pin RS232
RS485
Full-Duplex
RS485
Half-Duplex
2 TX232 TX485+ RTX485+
3 RX232 RX485+
4 RTS232 TX485- RTX485-
5 CTS232 RX485-
7 SGND SGND SGND
DS2400A QUICK GUIDE
4
Mechanical Installation:
23.3*
0.92
14
0.55
84
3.31
4
0.16
10.3
0.41
40
1.57
0.41
10.3
40
1.57
14.7
0.58
M 4 n° 4
1.29
32.7
mm
inch
68
2.68
46
1.81
DS2100A
9
4.2
7.8
20°
2.5
73
42
R
4
0
4
.
2
90°
30
13.8
17.5
2.5
23
mm
4
.
2
n
°
2
1 x 45° n° 2
* The quote refers to the scan line
Input/Output Connections:
INPUT NPN INPUT NPN MEP-543
EXT TRIG+
18
19
+ 5V
DS2400A
EXTERNAL TRIGGER
Signal
V
Vext 30 Vdc max.
EXT TRIG-
Input NPN command using external power
MEP-543 Connector
DS2400A
18
19
+ 5V
VS
9
25
GND
EXT TRIG+
EXT TRIG-
4 3
2 1
(brown)
(white)
(blue)
Input NPN command using MEP-543 Photocell
OUTPUT
EXTERNAL TRIGGER
DS2400A
Signal
18
19
+ 5V
VS
9
25
GND
Ground
V
EXT TRIG+
EXT TRIG-
Input NPN command using DS2400A power
USER INTERFACE
+
8/11
12/22
OUT REF
DS2400A
Vext 40 Vdc max.
C
E
Output open collector connections
INPUT PNP
18
19
+ 5V
DS2400A
EXTERNAL TRIGGER
V
Signal
Ground
EXT TRIG+
EXT TRIG-
Vext 30 Vdc max.
Input PNP command using external power
V
CE
max = 40 Vdc
I
max = 40 mA continuous
EXTERNAL TRIGGER
DS2400A
18
19
+ 5V
VS
9
25
GND
Ground
V
Signal
EXT TRIG+
EXT TRIG-
Input PNP command using DS2400A power
DS2400A
DS2400A QUICK GUIDE
5
Connectivity:
RS232 Main Interface Connections RS485 Main Interface Connections
RS232 Point-to-point layout RS485 Point-to-point layout
c Main Serial Interface (RS232) c Main Serial Interface (RS485 Full Duplex)
dAuxiliary Serial Interface (Local Echo) (RS232) dAuxiliary Serial Interface (Local Echo) (RS232)
eExternal Trigger (for On-Line Mode) eExternal Trigger (for On-Line Mode)
Pass-through layout Multiplexer layout
c Main Serial Interface (RS232) c Main Serial Interface (RS485 Half-Duplex)
dAuxiliary Serial Interface (RS232) dAuxiliary Serial Interface (Local Echo) (RS232)
eExternal Trigger (for On-Line Mode) eExternal Trigger (for On-Line Mode)
RS232 Master/slave layout RS485 Master/slave layout
c Main Serial Interface (Slaves RS232 only) c Auxiliary Serial Interface (RS232)
dAuxiliary Serial Interface (RS232) d Main Serial Interface (RS485 Half-Duplex)
eExternal Trigger (for On-Line Mode) eExternal Trigger
Host
MX4000
Host
DS2400
A
Terminal Host
DS2400
A
Terminal
Host
DS2400
A
DS2400
A
Host
DS2400
A
Slave
DS2400
A
Slave
DS2400
A
Maste
r
Host
DS2400
A
Slave
DS2400
A
Slave
DS2400
A
Maste
r
DS2400A QUICK GUIDE
6
Reading Diagrams:
DS2400A-0200 (Short Reading Range)
CONDITIONS
Optic Version = Linear
Code = Interleaved 2/5 or Code 39
PCS = 0.90
Pitch angle = 0°
Skew angle = 10°
Tilt angle = 0°
* Code Resolution = High
* Code Reading Condition = Standard
* Scanning Speed = Speed_3 (800 scans/s)
* Parameters selectable in WinHost.
0
10
cm
7,5
5
2,5
7,5
2,5
5
10
51015
20 25 30 35 cm
3
4
in
1
2
0
1
2
3
4
2
64
12
8
10
14 in
0.35 mm
(14 mils)
0.20 mm
(8 mils)
0.25 mm
(10 mils)
DS2400A-1200 (Medium Reading Range)
CONDITIONS
Optic Version = Linear
Code = Interleaved 2/5 or Code 39
PCS = 0.90
Pitch angle = 0°
Skew angle = 10°
Tilt angle = 0°
* Code Resolution:
High – for 0.25 mm (10 mils) codes
Std – for 0.35 mm (14 mils) codes and
greater
* Code Reading Condition = Standard
* Scanning Speed = Speed_3 (800 scans/s)
* Parameters selectable in WinHost.
0
20
cm
15
10
5
15
5
10
20
10 20 30
40 50 cm
6
8
in
2
4
0
2
4
6
8
4128
16
20
0.50 mm
(20 mils)
0.25 mm
(10 mils)
0.35 mm
(14 mils)
DS2400A QUICK GUIDE
7
DS2400A-2200 (Long Reading Range)
CONDITIONS
Optic Version = Linear
Code = Interleaved 2/5 or Code 39
PCS = 0.90
Pitch angle = 0°
Skew angle = 10°
Tilt angle = 0°
* Code Resolution:
High – for 0.35 mm (14 mils) codes
Std – for 0.50 mm (20 mils) codes and
greater
* Code Reading Condition = Standard
* Scanning Speed = Speed_3 (800 scans/s)
* Parameters selectable in WinHost.
0
5
10
15
20
5
10
15
20
cm
10 20 30 40 50 60 70 cm
0
8
in
6
4
2
6
2
4
8
48
12
16 20
24
28 in
0.50 mm
0.35 mm
(20 mils)
(14 mils)
User Interface:
The following table contains the pinout for standard RS232 PC Host interface. For other user interface types
please refer to their own manual.
RS232 PC-side connections
5
9 6
1
9-pin male connector
13
25 14
1
25-pin male connector
Pin Name Pin Name
2 RX 3 RX
3 TX 2 TX
5 GND 7 GND
7 RTS 4 RTS
8 CTS 5 CTS
How To Build A Simple Interface Test Cable:
The following wiring diagram shows a simple test cable including power, external (push-button) trigger and PC
RS232 COM port connections.
DS2400A
25-pin D-sub male
7
20
SGND
RXAUX
TXAUX
21
25
13
GND
VS
9-pin D-sub female
GND
TX
RX
PC
2
3
5
18
9
EXT TRIG+
VS
Power Supply
VS (10 – 30 Vdc)
Power GND
Trigger
EXT TRIG-
19
Test Cable for DS2400A
DATALOGIC S.p.A.,
Via Candini, 2
40012 - Lippo di Calderara
Bologna - Italy
05
dichiara che
declares that the
déclare que le
bescheinigt, daß das Gerät
declare que el
DS2400A-XXXX Laser Scanner e tutti i suoi modelli
and all its models
et tous ses modèles
und seine modelle
y todos sus modelos
sono conformi alle Direttive del Consiglio Europeo sottoelencate:
are in conformity with the requirements of the European Council Directives listed below:
sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous:
der nachstehend angeführten Direktiven des Europäischen Rats:
cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente:
89/336/EEC EMC Directive e 92/31/EEC, 93/68/EEC emendamenti successivi
and further amendments
et ses successifs amendements
und späteren Abänderungen
y succesivas enmiendas
Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica ed alla sicurezza dei prodotti.
On the approximation of the laws of Member States relating to electromagnetic compatibility and product safety.
Basée sur la législation des Etats membres relative à la compatibilité électromagnétique et à la sécurité des produits.
Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit
entsprechen.
Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y las Medidas
de seguridad relativas al producto.
Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette déclaration repose sur la conformité des produits aux normes suivantes:
Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht:
Esta declaración se basa en el cumplimiento de los productos con las siguientes normas:
EN 55022 (Class A ITE), August 1994:
Amendment A1 (Class A ITE), October 2000:
L
IMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE
CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT
EN 61000-6-2, October 2001: E
LECTROMAGNETIC COMPATIBILITY (EMC)
P
ART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL
ENVIRONMENTS
Lippo di Calderara, 08/09/2005
Ruggero Cacioppo
Quality Assurance Supervisor
821000923 (Rev. C1)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Datalogic DS2400A Quick Manual

Tipo
Quick Manual

in altre lingue