CET
VISUALIZED DIGITAL
PERIOD COUNTER
Type:
GFM50
PROGRAMMABLE DIGITAL VISUALIZATOR OF
ROTATIONS WITH 5 DIGITS, WITH INPUT SUITABLE
FOR MONO DIRCTIONAL COUNTING.
The period counter model GFM50 is used to display
rotational or linear speeds or counting referred to a pre
selected time base. All the common types of controls
are available using five different programmable
operations.
It reads signals coming form electromechanical and
logical contacts, proximity switches and encoder.
It finds application like RPM meter, tachometer, speed
meter, productions meter etc.
MAIN FEATURES
PROGRAMMABLE PARAMETERS
Frontal keyboard in polycarbonate (antiscratch, antioil,
antacid).
IP65 protection degree
Accessible parameters with key software
Removable terminals connection.
Execution DIN 48 x 48.
Recessed assembly.
Special retaining brackets.
Multiplier Factor
Divisor Factor
Time Base
Display Reset Time
Display Adjournment Time
Input for Electromechanical or Logic Contacts
Programmable Reset Key
Programmable Decimal Point
TECHNICAL FEATURES
POWER SUPPLY IN ALTERNATE CURRENT
POWER SUPPLY IN DIRECT CURRENT
POWER SUPPLY TOLERANCE
ABSORPTION
OPERATING TEMPERATURE
CLIMATIC CONDITIONS
COUNTER AND TOTALIZER VISUALIZATION
MULTIPLICATION FACTOR OF THE INPULSES IN INPUT
DIVISOR FACTOR OF THE INPULSES IN INPUT
TIME BASE
INPUT TYPE
MAXIMUM COUNT FREQUENCY
MINIMUM TIME FOR INPULSES COUNT
CUT OFF FREQUENCY FOR ELECTROMECHANICAL
INPUTS
AUXILIARY INPUT SUPPLY
PROGRAMMED DATA MEMORY
: 230 Vac (50 / 60 Hz).
: 24 Vdc
: +10% - 15%.
: 2 W - 3 VA.
: -5 °C + 55 °C.
: U.R. 95 % a 40 °C (without condensate).
: 5 digits, display high 7,5mm.
: programmable from 1 to 10000.
: programmable from 1 to 10000.
: Programmable between 1 / 60 / 3600.
: suitable for electromechanical contacts, amplified proximity
and encoder, NPN and PNP
: up to 25 KHz with Duty Cycle=50%.
: 0,25 mSec.
: about 30 Hz.
: 24 Vdc - 80 mA available on terminals.
: Static (no battery)
CET - s.r.l.
Vers. 1.0
GFM 50
Pag. 2
DESCRIPTION OF THE FRONTAL KEYBOARD
ø
WHITE
In programming phase it moves the cursor of the figure towards left of a step, than at the beginning it is on the right
side first one on the. At the end it resumes from the first one to right.
ù
WHITE
The key 'UP ARROW' in normal operating phase visualizes the totalizer of impulses.
In programming phase it increases the value of the blinking figure.
ú
WHITE
The key 'PRG' pressed for 2 sec. allows to enter in the programming phase, visualizing on display C.0000.
In the programming phase, pressing key 'PRG' impulsively, it exits from the programming phase. The instrument exits
automatically from the programming phase, 60 sec. after the pressure of the last key.
û
RED
The key 'ENT/RES' in normal phase of counting has the 'RESET' function, with the modalities to it attributed in the
programming phase.
In programming phase it confirms and memorizes the visualized data and passes to the successive function. If it has
arrived to list end it resumes from the beginning.
INPUTS / OUTPUTS DESCRIPTION - E SERIES
AC POWER SUPPLY
(inputs 1-2)
AC Power Supply Input of the instrument; it can be to 24 - 110 - 230 VAC in according to demand.
DPOWER SUPPLY
(inputs 3-4)
DC Power Supply Input of the instrument; input 3 (-), input 4 (+).
24 VDC - 80mA
(inputs 12-13)
24 VDC - 80 mA auxiliary Power Supply that the instrument supply to feed the Encoder and proximity amplified.
PRI
(input 10)
Input used for the polarization of the count and command inputs : connecting the PRI output to input 3 it configures
the instrument in Negative logic (NPN), connecting the PRI output to input 4 it configures the instrument in Positive
logic (PNP).
INPUT
(input 11)
Input of count adapted for electromechanical and logical contacts, encoder and 3 wires proximity amplified,
configurable in Positive (PNP) and Negative (NPN) logic through PRI input (10).
INPUTS / OUTPUTS DESCRIPTION - Z SERIES
AC/DC POWER
SUPPLY
(inputs 2 - 10)
AC or DC Power Supply Input of the instrument; it can be to 24 - 110 - 230 VAC or 12 - 24 VDC in according to
demand.
24 VDC - 80mA
(inputs 7 - 8)
24 VDC - 80 mA auxiliary Power Supply that the instrument supply to feed the Encoder and proximity amplified.
PRI
(input 9)
Input used for the polarization of the count and command inputs : connecting the PRI output to input 8 it configures
the instrument in Negative logic (NPN), connecting the PRI output to input 7 it configures the instrument in Positive
logic (PNP).
INPUT
(input 5)
Input of count adapted for electromechanical and logical contacts, encoder and 3 wires proximity amplified,
configurable in Positive (PNP) and Negative (NPN) logic through PRI input (9).
CET - s.r.l.
Vers. 1.0
GFM 50
Pag. 3
PROGRAMMING OF THE OPERATION PARAMETERS
The programmable parameters are divided in two groups and protect with a 4 figures code.
In order to approach the programming, proceed in the following way:
- Press key PRG for about 2 sec. On the display appears:
Cod
000
GROUP 1
:
in order to approach the parameters of group 1, insert code
101
and press
ENT
¾Æ
0001
F.M. = 4 digits multiplier , programmable from 1 to 10000. This parameter allows to multiply
the number of the input impulses, showing them on the display in an other format. If it
programmed = 0 it means programmed 10000.
Attention: the variation of the value of the multiplying modifies automatically the value of the
count and the totalizer.
¾¼
0001
F.d. = 4 digits divisor , programmable from 1 to 10000. This parameter allows to divide the
number of the input impulses, showing them on the display in an other format. If it programmed
= 0 it means programmed 10000.
Attention: the variation of the value of the multiplying modifies automatically the value of the
count and the totalizer.
ºÌ
60
b.t. = Time Base.
This programming allows to select in which time base shows on the display the measure in
input. There are three scales:
1 = Time Base: seconds, measure visualization in seconds (ex. Meters/seconds)
60 = Time Base: minutes, measure visualization in minutes (ex. Liters/minutes)
3600 = Time Base: hours, measure visualization in hours (ex. Bottles/hour)
-----
When the device is switched on and when there are no impulses in its input, the device visualize 4
horizontal bars.
Pressing the key ù the totalizer of impulses will be visualized for 5 sec.
Toì
99999
The totalizer visualizes all the impulses that the instrument counts from its input IN1.
It can be resetted through frontal key RES only or from RESET input when it is visualized on the display.
CET - s.r.l.
Vers. 1.0
GFM 50
Pag. 4
PROGRAMMING OF THE OPERATION PARAMETERS
The programmable parameters are divided in two groups and protect with a 4 figures code.
In order to approach the programming, proceed in the following way:
- Press key
PRG
for about 2 sec. On the display appears:
Cod
000
GROUP 2
:
in order to approach the parameters of GROUP 2, insert code
020
and press
ENT
̼ Ç1
t.d. = Updating time of the display.
This parameter allows to program the delay time of the data adjournment on the
display. It’s programmable between 0 (instantaneous) and 9,9 sec
1æ F
1æ 5
Input Fast - Slow.
This programming allows to set the count input to read signals coming from electromechanical
contacts (relays, switches etc.) or from logical signals like proximity switches transistor and
encoder.
In = F. sets the input to read digital signals up to 28 KHz.
In = S. sets the input to read electromechanical signals up to 25 Hz.
rËoí
Operation of the RESET Key; this programming enable and disable the RESET working of
the frontal RES key during the operation, as in the following modes:
RS.on. = executes the RESET of the visualized parameter
RS.oF. = RESET working of the RES key excluded.
¼È O
¼È 4
d.P. = Programming of the Decimal Point
This programming allows to add a decimal point to the visualization on the 4 digits, in order to
obtain counts with various resolutions.
d.p. = 0 Decimal Point excluded; visualization 99999
d.p. = 1 Decimal Point on the second display from right; visualization 9999,9
d.p. = 2 Decimal Point on the third party display from right; visualization 999,99
d.p. = 3 Decimal Point on the fourth display from right; visualization 99,999
d.p. = 4 Decimal Point on the fifth display from right; visualization 9,9999
d.p. = 5 Floating Point.
¹È È
¹È ê
A.P. = Activation mode of the programmed parameters.
With this programming is possible to activate the executed programmings directly to the exit of
the programming or, when exited of the programming, after a RESET (with frontal key or from
rear input).
A.P. = P. Activation of the parameters to the exit of the programming.
A.P. = r. Activation of the parameters to the exit of the programming after a RESET.
CET - s.r.l.
Vers. 1.0
GFM 50
Pag. 5
Programming Notes
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
CET - s.r.l.
Vers. 1.0
GFM 50
Pag. 6
DECLARATION OF ‘CE’ CONFORMITY
CE NORMATIVE CONFORMITY
Borgolavezzaro, October, 03rd 2005
The building firm:
CET s.r.l.
Head office:
Strada Statale 211, Km 53,3
28071 Borgolavezzaro (No) ITALIA
Tel. 0039 - 321 - 885301 Fax. 0039 - 321 - 885560
declare that the products:
type :
Visualized Digital Period Counter
model:
GFM50
use class:
Industrial
are in conformity with the following normatives:
EN55011
ENV50141
ENV50204
EN61000-4-2
EN61000-4-4
The constructor :
CET s.r.l.
________________________________
Signature
CET - s.r.l.
Vers. 1.0
GFM 50
Pag. 7
Z SERIES - CONNECTIONS
Z SERIES - INPUT SIGNALS
NPN
-
+ - + -
+ +
INPUT FOR INPUT FOR INPUT FOR
NPN NPN PROXIMITY AND
CONTACT LOGIC ENCODER
AMPLIFIED
24 VDC
PNP
-
- + - + -
+
INPUT FOR
INPUT FOR INPUT FOR
PNP PNP PROXIMITY AND
CONTACT
LOGIC ENCODER
AMPLIFIED
24 VDC
Z SERIES - CONNECTIONS
E SERIES - INPUT SIGNALS
NPN
-
+ - + - + +
INPUT FOR INPUT FOR INPUT FOR
NPN NPN PROXIMITY AND
CONTACT LOGIC
ENCODER
AMPLIFIED
24 VDC
PNP
-
- + - + -
+
INPUT FOR INPUT FOR INPUT FOR
PNP PNP PROXIMITY AND
CONTACT
LOGIC ENCODER
AMPLIFIED
24 VDC
7
5
8
9
5
7
8
9
8
9
PROX
ENC
7
8
5
8
5
7
9
5
8
7
9
7
9
PROX
ENC
7
8
5
12
11
13
10
11
12
13
10
13
10
PROX
ENC
12
13
11
13
11
12
10
11
13
12
10
12
10
PROX
ENC
12
13
11
PRI
1
GND
11
2
3
4
5
6
7
8
9
1
0
+ 24 VDC
CNT
24 VDC
-
+
DC POWER
SUPPLY
PRI
1
GND
11
2
3
4
5
6
7
8
9
10
+ 24VDC
CNT
AC POWER
SUPPLY
-
+
24 VDC
INPUT
7
8
9
10
11
12
13
1
2
3
4
5
6
PRI
AC POWER
SUPPLY
24 VDC
-
+
CET - s.r.l.
Vers. 1.0
GFM 50
Pag. 8
OVERALL DIMENSIONS (mm)
FRONT DRILL TEMPLATE
E SERIES SIDE Z SERIES SIDE
E SERIES REAR
Z SERIES REAR
CET
CETCET
CET
CET
CETCET
CET
S.r.l
Strada Statale 211 Km 53,550
28071 Borgolavezzaro - NO - ITALY
Tel : ++39 0321-885180/885301/885807
Fax : ++39 0321-885560
http://www.cet-italy.com
e-mail: info@cet-italy.com
Agent:
45
45
48
48
ENT
PRG
electronic counter GFM
L1 L2
RES
CET
CETCET
CET
54952
116
93
4
19
44x44
REMOVABLE
TERMINALS
RETAINING
BRACKETS
10
116
93
4
12
44x44
UNDECAL
SOCCAL
RETAINI
NG
BRACKETS
10
44
44
7 8 9 10 11 12 13
1 2 3 4 5 6
44
44
1 11
2
3
4
5
6
7
8
9
10
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

CET GFM50 Manuale del proprietario

Tipo
Manuale del proprietario

in altre lingue