Furuno GP-320B Manuale del proprietario

Tipo
Manuale del proprietario
GPS RECEIVER
GP-320B
OPERATOR'S MANUAL
www.furuno.com
Model
i
Ni-Cd Pb
IMPORTANT NOTICES
General
This manual has been authored with simplified grammar, to meet the needs of
international users.
The operator of this equipment must read and follow the instructions in this manual.
Wrong operation or maintenance can void the warranty or cause injury.
Do not copy any part of this manual without written permission from FURUNO.
If this manual is lost or worn, contact your dealer about replacement.
The contents of this manual and the equipment specifications can change without
notice.
The example screens (or illustrations) shown in this manual can be different from the
screens you see on your display. The screens you see depend on your system
configuration and equipment settings.
Save this manual for future reference.
Any modification of the equipment (including software) by persons not authorized by
FURUNO will void the warranty.
The following concern acts as our importer in Europe, as defined in DECISION No
768/2008/EC.
- Name: FURUNO EUROPE B.V.
- Address: Ridderhaven 19B, 2984 BT Ridderkerk, The Netherlands
All brand, product names, trademarks, registered trademarks, and service marks belong
to their respective holders.
How to discard this product
Discard this product according to local regulations for the disposal of industrial waste. For
disposal in the USA, see the homepage of the Electronics Industries Alliance
(http://www.eiae.org/) for the correct method of disposal.
How to discard a used battery
Some FURUNO products have a battery(ies). To see if your product has a battery, see the
chapter on Maintenance. Follow the instructions below if a battery is used. Tape the + and -
terminals of battery before disposal to prevent fire, heat generation caused by short circuit.
In the European Union
The crossed-out trash can symbol indicates that all types of
batteries must not be discarded in standard trash, or at a trash
site. Take the used batteries to a battery collection site
according to your national legislation and the Batteries Directive
2006/66/EU.
In the USA
The Mobius loop symbol (three chasing arrows) indicates that
Ni-Cd and lead-acid rechargeable batteries must be recycled.
Take the used batteries to a battery collection site according to
local laws.
In the other countries
There are no international standards for the battery recycle symbol. The number of symbols
can increase when the other countries make their own recycling symbols in the future.
Cd
ii
SAFETY INSTRUCTIONS
Confirm that the power supply voltage
is compatible with the voltage rating
of the equipment.
Connection to the wrong power supply can
cause fire or damage the equipment.
CAUTION NOTICE
No one navigation device should ever
be solely relied upon for the navigation
of a vessel.
Always confirm position against all
available aids to navigation, for safety of
vessel and crew.
iii
TABLE OF CONTENTS
SYSTEM OVERVIEW........................................................................................... iv
EQUIPMENT LISTS ............................................................................................. vi
1. MOUNTING ....................................................................................................... 1
2. WIRING ............................................................................................................. 2
3. DEFAULT SETTINGS ....................................................................................... 6
4. TROUBLESHOOTING, BATTERY.................................................................... 7
SPECIFICATIONS........................................................................................... SP-1
PACKING LIST.................................................................................................. A-1
OUTLINE DRAWING ........................................................................................ D-1
iv
SYSTEM OVERVIEW
The GP-320B is a GPS receiver with WAAS (Wide Area Augmentation System) capability.
WAAS, available in North America, is a provider in the worldwide SBAS (Satellite Based
Augmentation System) navigation system. This system provides GPS signal corrections to
SBAS users, for even better position accuracy, typically better than three meters. There are
three more SBAS providers, MSAS (Multi-Functional Satellite Augmentation System) for Japan,
EGNOS (Euro Geostationary Navigation Overlay Service) for Europe and GAGAN (GPS And
GEO Augmented Navigation) for India. The illustration below shows the coverage area.
(Accuracy may be affected when using a GEO satellite not within your current location.) This
manual uses “WAAS” for these three providers generically.
WAAS
MSAS
EGNOS
GAGAN
Provider Satellite type Longitude Satellite No.
Intelsat Galaxy XV 133°W 135
TeleSat Anik F1R 107.3° 138
WAAS
Inmarsat-4-F3 98°W 133
Inmarsat-3-F2/AOR-E 15.5°W 120
Artemis 21.5°E 124
EGNOS
Inmarsat-4-F2 25°E 126
MTSAT-1R 140°E 129
MSAS MTSAT-2 145°E 137
GAGAN Inmarsat-4-F1 64°E 127
v
Other Equipment*
JUNCTION BOX
GD-XXXX
GR-80
Ship's Mains (12-24 VDC)
Multi Display RD-30*
Echo Sounder LS-6100
NavNet Series
Model 1722C Model 1833C
Model 1722 Model 1933C
Model 1732C Model 1943C
Model 1732 Model 1833
Model 1742C Model 1933
Model 1742 Model 1943
Model 1752C Model 1953C
Model 1752 GD-1900C
Model 1762C GD-1700C
Model 1762 GD-1700
* = WAAS is inoperative.
This GPS receiver complies with Canadian standard RSS-210 (Low Power
License-Exempt Radio communication Devices).
Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may
cause undesired operation of the device.
Program No.
4850264***
** denotes minor modifications.
CE declaration
With regards to CE declarations, please refer to our website (www.furuno.com), for further
information about RoHS conformity declarations.
vi
EQUIPMENT LISTS
Standard supply
Name Type Code No. Qty Remarks
GPS Receiver GP-320B 1 With 10 m cable
Optional equipment
Name Type Code No. Qty Remarks
Cable Assembly MJ-A7SPF/SRMD-100 000-144-534 1 7P-7P, straight,
10 m
Mast Mounting Kit CP20-01111 004-365-780 1
Right Angle
Antenna Base NO.13-QA330 000-803-239 1
L-angle Antenna
Base NO.13-QA310 000-803-240 1
Handrail-mount
Antenna Base NO.13-RC5160 000-806-114 1
1
1. MOUNTING
NOTICE
Do not apply paint, anti-corrosive
sealant or contact spray to coating or
plastic parts of the equipment.
Those items contain organic solvents that
can damage coating and plastic parts,
especially plastic connectors.
Mounting considerations
Follow the guidelines below to choose a suitable mounting location for the antenna unit.
The antenna may be mounted three ways: screwed into a pipe (local supply), fixed to a
post with the optional mast mounting kit, or screwed into an optional mounting base. For
fixing by the post or pipe, it is recommended to use stays to prevent damage to the GPS
receiver.
Select a location out of the radar beam. The radar beam will obstruct or prevent
reception of the GPS signal.
The location should be well away from a VHF antenna. A GPS receiver is interfered by a
harmonic wave of a VHF antenna.
The location should be well away from an Inmarsat antenna. Inmarsat transmission will
obstruct or prevent reception of the GPS signal.
There should be no interfering object within the line-of-sight to the satellites. Objects
within line-of-sight to a satellite, for example, a mast, may block reception or prolong
acquisition time.
Mount the antenna unit as high as possible to keep it free of interfering objects and
water spray, which can obstruct reception of the GPS signal if the water freezes.
Observe the following minimum separation distances from other antenna units.
a
1.5 m
MAIN MAST
TX ANTENNA(MF/HF)
NOT WITHIN RADAR BEAM
* = DISTANCE DEPENDS ON MAST DIAMETER OF ’a’.
4 m
4 m
1 m1 m
3 m
INMARSAT ANTENNA
LOOP ANTENNA
RX WHIP ANTENNA
5 m
NOT WITHIN INMARSAT BEAM
0.5 m
WHIP ANTENNA(VHF/UHF) WHIP ANTENNA(MF/HF)
GPS ANTENNA
DIA. OF ’a’ DISTANCE (MIN.)
3 m
1.5 m
10 cm
30 cm
*
Mounting procedure
Install the antenna unit by referring to the installation diagram on page D-1.
2
2. WIRING
This unit outputs position and speed to external equipment. NavNet equipment, Multi
Display RD-30 and Echo Sounder LS-6100 can be connected directly. For connection to
other equipment, use a junction box (local supply) which has seven terminals.
The antenna cable is 10 meters long. If the distance between the antenna unit and the
display monitor is more than 10 meters, use the optional cable assy. (10 m). Up to four
extension cables can be connected serially.
Connecting to FURUNO NavNet equipment
Connect the antenna cable to the DATA1 port on NavNet equipment.
Total length: Max. 50 m
Cable assy. (option)
MJ-A7SPF/SRMD-100
10 m (max. 4)
Antenna Cable
10 m
DATA 1 port
NavNet
Waterproofing connectors
If you use the cable assy.(s), waterproof their connectors by wrapping them with vulcanizing
tape and then vinyl tape. Bind tape ends with suitable cable-ties.
3
Connecting to Multi Display RD-30
WAAS is not operative in this installation.
Antenna Cable
10 m
MULTI DISPLAY
RD-30
AUX port
IN/OUT port
12-24 VDC
AUX
IN/OUT
12-24
VDC
Rear Panel
Connecting to Echo Sounder LS-6100
Antenna Cable
10 m ECHO SOUNDER
LS-6100
REAR
NMEA
XDR
POWER
12VDC
POWER
12 VDC
NMEA
4
Connecting to other equipment
Remove the connector from the antenna cable and attach crimp-on lugs or similar terminals
to the cable’s cores. Connect the cores to the junction box as below.
Antenna Cable
10 m non-NavNet equipment
RS-422*
1
input for radar/plotter
Correction data from GR-80
output in RS-422 format
12-24 VDC*
2
(Input current: 105-55 mA)
NMEA 0183 Ver. 2.0
*1: RS-422 signal can
be received by using
current loop.
1
2
3
4
5
6
7
WHITE
BLACK
YELLOW
JUNCTION BOX
GREEN
RED
BLUE
Drain Wire
1
2
3
4
Fuse 0.5 A
RD-A
RD-B
TD-A
TD-B
Switchboard breaker
*2: Supply from breaker on switchboard
Note 1: When connecting FURUNO DGPS beacon receiver GR-80 to this unit, set it as
follows:
Byte Format, 8-6; First Bit, LSB; Parity Bit, None; Stop Bit, 1; Bit Rate, 8.
Note 2: The signal ground and frame ground are separated, however the power line is not
isolated. Therefore, do not connect the signal ground to the frame ground when
other equipment is connected to a positive ground battery.
Note 3: WAAS function is inoperative when wiring as shown above.
5
Output/Input data sentences
Priority Input Data Output Data
Settable
Output
Cycle
Default
Output
GPDTM Geometric datum Yes Yes
XXGGA GPS position
status (time of fix,
latitude, longitude,
receive status,
satellite used)
GPGGA GPS fix data Yes Yes
XXZDA UTC date (time in
minutes and
seconds, day,
month, year, time)
GPZDA UTC time and date Yes Yes
XXGLL Position (latitude,
longitude)
GPGLL Geographic
position, latitude
and longitude
Yes Yes
GPVTG Course over
ground and ground
speed
Yes Yes
High
Low
XXRMC Navigation data
(UTC time and
latitude, longitude,
ground speed,
true course, year,
month, day)
GPRMC Recommended
minimum specific
GPS/TRANSIT
data
Yes Yes
Note 1: Data output from high to low priority.
Note 2: GPDTM data is attached in front of GPGGA, GPGLL and GPRMC when those
sentences are output.
Note 3: “XX” means talker ID.
6
3. DEFAULT SETTINGS
Setting Default setting Backup
Initial Latitude/Longitude North=34°44.0000, East=135°21.0000 Yes
Date, Time 2001/1/1, 00:00:13 Yes
Antenna Height 0 m Yes
Almanac Data Yes
G
P
S
Ephemeris Data Yes
Local Zone Time +0 Yes
PDOP 6 Yes
Geometric Datum WGS84 Yes
Mask Elevation 5° Yes
Disable Satellite None No
Smoothing Coefficient 2 (Standard) No
Dynamic Coefficient 2 (Standard) No
Data Output (Cycle) DTM, GGA, ZDA, GLL, VTG, RMC (1 s) Yes
R
E
C
E
I
V
E
R
DGPS Setting Parameter 1 (LSB first) Yes
GEO Satellite, Provider ID Auto: from 120, in sequential order No
WAAS Availability OFF No
W
A
A
S
Type 0 Message 0: Correct data not output for 60 s Yes
7
4. TROUBLESHOOTING, BATTERY
Troubleshooting
If the message “No position data” appears on the display of NavNet equipment, there may
be a problem with the GPS receiver. Turn off the power and then check the following points:
1) Check for objects around the antenna which may interfere with reception.
2) Check that the antenna cable is firmly fastened.
3) If extension cable(s) are used, check for water leakage at junction point(s).
4) Check the antenna cable for damage.
5) Check the antenna for damage.
If the problem seems to be with the antenna cable or antenna, contact your dealer.
Battery
The antenna unit contains a lithium battery which preserves data when the power is turned
off, and its life is approximately 20 years (operating rate 70%) for large vessels and 10
years (operating rate 20%) for small vessels. The equipment can be used when the voltage
of the battery is low, however data is not backed up and the unit starts up in the “cold start”
condition.
FURUNO
GP-320B
SP - 1 E4422S01C
201105
SPECIFICATIONS OF GPS RECEIVER
GP-320B
1 GENERAL
1.1 Receiving channels
GPS 12 channels parallel, 12 satellites tracking
WAAS 1 channel
1.2 Rx frequency 1575.42 MHz
1.3 Rx code C/A code, WAAS
1.4 Position accuracy
GPS 10 m (95% of the time, HDOP 4)
DGPS 5 m (95% of the time, external data required)
WAAS 3 m (95% of the time)
1.5 Tracking velocity 999 kt
1.6 Position-fixing time Warm start: 12 s approx., Cold start: 90 s approx.
1.7 Position update interval 1 s
2 INTERFACE
2.1 Data format IEC 61162-1 (NMEA 0183 Ver 2.30)
2.2 Data sentences
Input DGPS: RTCM SC-104, Control command
Output DTM, GGA, GLL, RMC, VTG, ZDA (default setting)
3 POWER SUPPLY
12-24 VDC (10.8-31.2 V): 105-55 mA
4 ENVIRONMENTAL CONDITION
4.1 Ambient temperature -25°C to +70°C
4.2 Relative humidity 95% at 40°C
4.3 Degree of protection IPX6
4.4 Vibration IEC 60945
5 UNIT COLOR
N9.5
PACKING LIST
20AW-X-9852 -1
GP-320B(E)
N A M E O U T L I N E DESCRIPTION/CODE № Q'TY
1/1
ユニット UNIT
GPS受信機
GPS RECEIVER
GP-320B(E)
004-367-500-00
1
図書 DOCUMENT
取扱説明書
OPERATOR'S MANUAL
OME-44220-*
000-809-291-1*
1
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER
PRODUCT. QUALITY IS THE SAME.
A-1
D-1
Sep.20 '02
FURUNO Worldwide Warranty for Pleasure Boats (Except North America)
This warranty is valid for products manufactured by Furuno
Electric Co. (hereafter FURUNO) and installed on a pleasure
boat. Any web based purchases that are imported into other
countries by anyone other than a FURUNO certified dealer may
not comply with local standards. FURUNO strongly recommends
against importing these products from international websites as
the imported product may not work correctly and may interfere
with other electronic devices. The imported product may also be
in breach of the local laws and mandated technical requirements.
Products imported into other countries as described previously
shall not be eligible for local warranty service.
For products purchased outside of your country please contact
the national distributor of Furuno products in the country where
purchased.
This warranty is in addition to the customer´s statutory legal
rights.
1. Terms and Conditions of Warranty
FURUNO guarantees that each new FURUNO product is the
result of quality materials and workmanship. The warranty is
valid for a period of 2 years (24 months) from the date of the
invoice, or the date of commissioning of the product by the
installing certified dealer.
2. FURUNO Standard Warranty
The FURUNO standard warranty covers spare parts and labour
costs associated with a warranty claim, provided that the product
is returned to a FURUNO national distributor by prepaid carrier.
The FURUNO standard warranty includes:
Repair at a FURUNO national distributor
All spare parts for the repair
Cost for economical shipment to customer
3. FURUNO Onboard Warranty
If the product was installed/commissioned and registered by a
certified FURUNO dealer, the customer has the right to the
onboard warranty.
The FURUNO onboard warranty includes
Free shipping of the necessary parts
Labour: Normal working hours only
Travel time: Up to a maximum of two (2) hours
Travel distance: Up to a maximum of one hundred
and sixty (160) KM by car for the complete journey
4. Warranty Registration
For the Standard Warranty - presentation of product with serial
number (8 digits serial number, 1234-5678) is sufficient.
Otherwise, the invoice with serial number, name and stamp of
the dealer and date of purchase is shown.
For the Onboard Warranty your FURUNO certified dealer will
take care of all registrations.
5. Warranty Claims
For the Standard Warranty - simply send the defective product
together with the invoice to a FURUNO national distributor.
For the Onboard Warranty – contact a FURUNO national
distributor or a certified dealer. Give the product´s serial number
and describe the problem as accurately as possible.
Warranty repairs carried out by companies/persons other than a
FURUNO national distributor or a certified dealer is not covered
by this warranty.
6. Warranty Limitations
When a claim is made, FURUNO has a right to choose whether
to repair the product or replace it.
The FURUNO warranty is only valid if the product was correctly
installed and used. Therefore, it is necessary for the customer to
comply with the instructions in the handbook. Problems which
result from not complying with the instruction manual are not
covered by the warranty.
FURUNO is not liable for any damage caused to the vessel by
using a FURUNO product.
The following are excluded from this warranty:
a. Second-hand product
b. Underwater unit such as transducer and hull unit
c. Routine maintenance, alignment and calibration
services.
d. Replacement of consumable parts such as fuses,
lamps, recording papers, drive belts, cables, protective
covers and batteries.
e. Magnetron and MIC with more than 1000 transmitting
hours or older than 12 months, whichever comes first.
f. Costs associated with the replacement of a transducer
(e.g. Crane, docking or diver etc.).
g. Sea trial, test and evaluation or other demonstrations.
h. Products repaired or altered by anyone other than the
FURUNO national distributor or an authorized dealer.
i. Products on which the serial number is altered,
defaced or removed.
j. Problems resulting from an accident, negligence,
misuse, improper installation, vandalism or water
penetration.
k. Damage resulting from a force majeure or other natural
catastrophe or calamity.
l. Damage from shipping or transit.
m. Software updates, except when deemed necessary
and warrantable by FURUNO.
n. Overtime, extra labour outside of normal hours such as
weekend/holiday, and travel costs above the 160 KM
allowance
o. Operator familiarization and orientation.
FURUNO Electric Company, March 1, 2011
FURUNO Warranty for North America
FURUNO U.S.A., Limited Warranty provides a twenty-four (24) months LABOR and twenty-four (24) months PARTS
warranty on products from the date of installation or purchase by the original owner. Products or components that are
represented as being waterproof are guaranteed to be waterproof only for, and within the limits, of the warranty
period stated above. The warranty start date may not exceed eighteen (18) months from the original date of purchase
by dealer from Furuno USA and applies to new equipment installed and operated in accordance with Furuno USA’s
published instructions.
Magnetrons and Microwave devices will be warranted for a period of 12 months from date of original equipment
installation.
Furuno U.S.A., Inc. warrants each new product to be of sound material and workmanship and through its authorized
dealer will exchange any parts proven to be defective in material or workmanship under normal use at no charge for a
period of 24 months from the date of installation or purchase.
Furuno U.S.A., Inc., through an authorized Furuno dealer will provide labor at no cost to replace defective parts,
exclusive of routine maintenance or normal adjustments, for a period of 24 months from installation date provided the
work is done by Furuno U.S.A., Inc. or an AUTHORIZED Furuno dealer during normal shop hours and within a radius
of 50 miles of the shop location.
A suitable proof of purchase showing date of purchase, or installation certification must be available to Furuno U.S.A.,
Inc., or its authorized dealer at the time of request for warranty service.
This warranty is valid for installation of products manufactured by Furuno Electric Co. (hereafter FURUNO). Any
purchases from brick and mortar or web-based resellers that are imported into other countries by anyone other than a
FURUNO certified dealer, agent or subsidiary may not comply with local standards. FURUNO strongly recommends
against importing these products from international websites or other resellers, as the imported product may not work
correctly and may interfere with other electronic devices. The imported product may also be in breach of the local
laws and mandated technical requirements. Products imported into other countries, as described previously, shall not
be eligible for local warranty service.
For products purchased outside of your country please contact the national distributor of Furuno products in the
country where purchased.
WARRANTY REGISTRATION AND INFORMATION
To register your product for warranty, as well as see the complete warranty guidelines and limitations, please visit
www.furunousa.com and click on “Support”. In order to expedite repairs, warranty service on Furuno equipment is
provided through its authorized dealer network. If this is not possible or practical, please contact Furuno U.S.A., Inc.
to arrange warranty service.
FURUNO U.S.A., INC.
Attention: Service Coordinator
4400 N.W. Pacific Rim Boulevard
Camas, WA 98607-9408
Telephone: (360) 834-9300
FAX: (360) 834-9400
Furuno U.S.A., Inc. is proud to supply you with the highest quality in Marine Electronics. We know you had several
choices when making your selection of equipment, and from everyone at Furuno we thank you. Furuno takes great
pride in customer service.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Furuno GP-320B Manuale del proprietario

Tipo
Manuale del proprietario