Sentiotec Pro C3 Manuale utente

Tipo
Manuale utente

Questo manuale è adatto anche per

Version 09/23 Ident no 1-026-969
INSTRUCTIONS FOR INSTALLATION AND USE
English
EN
DE
FR
IT
NL
SV
FI
Sauna control unit
PRO C2 / PRO C3
PRO-C3 / 1-015-451
PRO-C2 / 1-015-448
Table of Contents
1. About this instruction manual 5
2. Important information for your safety 6
2.1. Intended use 6
2.2. Safety information for the installer 7
2.3. Safety information for the user 8
3. Product description 9
3.1. Scope of delivery 9
3.2. Optional accessories 9
3.3. Product features 9
3.4. Sauna operating modes 11
3.5. Sensor operating modes 11
4. Installation 13
4.1. Installing the sauna control unit 13
4.2. Installing the heater sensor F1 with overheat cut-out 15
4.3. Installing bench sensor F2 (optional) 16
4.4. Installing humidity/temperature sensor FTS2 (optional, PRO C3 only)
16
4.5. Installing the foil sensor (optional) 16
5. Electrical connection 17
5.1. Connecting the power supply cable, heater and vaporizer 18
5.2. Connecting the light 18
5.3. Connecting the fan (optional) 18
5.4. Connecting the additional output (optional) 19
5.5. Connecting the power booster (optional) 19
5.6. Connecting the heater sensor F1 19
5.7. Installing bench sensor F2 (optional) 20
5.8. Connecting the humidity/temperature sensor FTS2 (optional,
PRO C3 only) 20
EN
5.9. Connecting the foil sensor (optional) 20
5.10. Connectingthesafetyshut-o/doorsensor 21
5.11. Remote start 21
5.12. Status output 21
5.13. Finishing the installation 21
6. Testing 22
7. Connection diagram 23
8. Commissioning 24
8.1. Setting the function selection switch 24
8.2. Settings in the technician menu 26
9. Controls 31
9.1. Description of the operating elements 31
9.2. The function selector 31
10. Operation 32
10.1. Switching on the light 32
10.2. Switching on the sauna control unit 32
9.3. The intensity selector 32
10.3. Starting sauna mode 33
10.4. Starting Combi mode (PRO C3 only) 33
10.5. Starting additional output 34
10.6. Switching on the light 36
10.7. Starting the fan 37
10.8. Setting the preset time 37
10.9. Cancelling the preset time feature 38
10.10. Setting the duration 38
10.11. Activating standby for remote operation 39
10.12. Changing the preset values 40
10.13. Stopping the post-drying programme 40
10.14.Switchingothesaunacontrolunit 40
11. User programs 41
11.1. Preset user programs 41
11.2. Creating your own user programs 41
12. The Eco-function 42
13. Cleaning and maintenance 43
13.1. Cleaning 43
13.2. Maintenance 43
14. Disposal 43
15. Troubleshooting 44
15.1. Error messages 44
15.2. Low-water display (PRO C3 only) 45
15.3. Fuses 45
16. Technical data 46
EN
Instructions for installation and use p. 5/47
1. About this instruction manual
Read these installation and operating instructions carefully and keep them within
reach of the sauna control unit. This ensures that you can refer to information on
safety and operation at any time.
Symbols used for warning notices
In these instructions for installation and use, a warning notice located next to
an activity indicates that this activity poses a risk. Always observe the warning
notices. This prevents damage to property and injuries, which in the worst case
may be fatal.
The warning notices contain keywords, which have the following meanings:
DANGER!
Serious or fatal injury will occur if this warning notice is not observed.
WARNING!
Serious or fatal injury can occur if this warning notice is not observed.
CAUTION!
Minor injuries can occur if this warning notice is not observed.
ATTENTION!
This keyword is a warning that damage to property can occur.
Other symbols
This symbol indicates tips and useful information.
These installation and operating instructions can also be found in the
downloads section of our website: www.sentiotec.com/downloads.
Instructions for installation and use p. 6/47
2. Important information for your safety
The PRO C2 / PRO C3 sauna control unit has been manufactured
in accordance with the applicable safety regulations. However,
hazards may arise during use. Therefore adhere to the following
safetyinformationandthespecicwarningnoticesintheindivid-
ual chapters. Also observe the safety information for the devices
connected.
2.1. Intended use
The PRO C2 / PRO C3 sauna control unit is used exclusively for
operating and controlling the sauna functions in accordance with
the technical data.
The PRO C2 / PRO C3 sauna control unit may only be used for
operatingandcontrollingasaunaheaterwhichhasbeencertied
as satisfying the combustion test described in paragraph 19.101 of
EN 60335-2-53. If the heater does not meet this requirement, an
appropriate safety precaution must be taken (for example: Safety
shut-o/door-opensensor,see5.10 on page 21).
The PRO C2 / PRO C3 sauna control unit may only be used for
operating and controlling 3 heating circuits with a maximum heating
output of 3.5 kW per heating circuit. The maximum additional out-
put totals 3.5 kW. The maximum vaporizer output (PRO C3 only)
is 3.5 kW.
Any use exceeding this scope is considered improper use. Improper
use can result in damage to the product, severe injuries or death.
EN
Instructions for installation and use p. 7/47
2.2. Safety information for the installer
Installationmayonlybeperformedbyaqualiedelectricianor
similarlyqualiedperson.
Work on the sauna control unit may only be performed when the
power has been disconnected.
A fully disconnecting all-pole isolating device compliant with
overvoltagecategoryIIImustbettedonsite.
The sauna control unit must be installed outside the sauna cabin
at a height of approx. 1.70 m or in accordance with the rec-
ommendation issued by the sauna manufacturer. The ambient
temperature must be within a range spanning -10 °C to +40 °C.
The heater sensor must be installed in such a way that it is not
aectedbyinowingair.
The heater supply cable must have a minimum cross-sectional
area of 2.5 mm2 and be temperature-resistant up to 150 °C.
Also comply with the regulations applicable at the installation
location.
For your own safety, consult your supplier in the event of prob-
lemsthatarenotexplainedinsucientdetailintheinstallation
instructions.
Instructions for installation and use p. 8/47
2.3. Safety information for the user
The sauna control unit must not be used by children under 8 years
of age.
The sauna control unit may be used by children over 8 years of
age, by persons with limited psychological, sensory or mental
capabilities or by persons with lack of experience/knowledge,
but only if:
They are supervised.
They have been shown how to use the device safely and
are aware of the hazards that could occur.
Children must not play with the sauna control unit.
Children under 14 years of age may only clean the sauna control
unit if they are supervised.
● Forhealthreasons,donotusethesaunawhenundertheinu-
ence of alcohol, medication or drugs.
● Makesurethatnoammableobjectshavebeenplacedonthe
sauna heater before the sauna control unit is switched on.
● Makesurethatnoammableobjectshavebeenplacedonthe
sauna heater before activating the preset time function or the
standby mode for remote start.
Makesurethatnoammableobjectshavebeenplacedonor
in front of the infrared heater before the sauna control unit is
switched on.
Makesurethatnoammableobjectshavebeenplacedonor
in front of the infrared heater before activating the preset time
function or the stand-by mode for the remote start.
For your own safety, consult your supplier in the event of prob-
lemsthatarenotdescribedinsucientdetailintheoperating
instructions.
EN
Instructions for installation and use p. 9/47
3. Product description
3.1. Scope of delivery
Sauna control unit
Heater sensor with integrated overheat cut-out
Installation material
3.2. Optional accessories
Bench sensor (1-009-231 / O-F2)
Humidity/temperature sensor (1-010-081 / O-FTS2)
Foil sensor (1-014-445 / P-ISX-FF)
Power booster (1-008-779 / O-S2-18, 1-009-280 / O-S2-30)
● Cut-orockerswitch(SFE-xxxxx)
Home door sensor (1-052-723 / SAB00103)
● MySentioWi(1-053-313/S-WIFI01)
MySentio Remote (1-053-314 / S-WIFI02)
3.3. Product features
The sauna control unit Pro C2 features the following functions:
Regulation of sauna heaters with a heating output of up to 10.5 kW in the
temperature range spanning 30 °C to 110 °C.
A power booster allows the maximum switching capacity to be increased from
10.5 kW to 18 kW or 30 kW.
Optional dimming or switching of a cabin light (up to 100 W)
Optional modulation or switching of a fan (up to 100 W)
Remote start function
Door monitoring system
Status output
Preset time function (up to 24 hours)
Automatic heating time limit
The sauna control unit shuts down automatically after the maximum heating
time for safety reasons. The maximum heating period can be set to 6 h, 12 h,
18 h or 24 h.
Instructions for installation and use p. 10/47
Auxiliary output
Either for dimming (up to 500 W), switching (up to 3.5 kW) or regulating the
sauna cabin temperature via the additional output.
The additional output has no overheat cut-out. For this reason, only intrinsically
safe devices should be operated using the additional output.
If infrared heaters are connected to the additional output, they must
have an overheat cut-out. We recommend using the following infrared
heaters:
DIR-350-R, WIR-350-R, DIR-500-R, WIR-500-R, DIR-750-R,
WIR-750-R, DIR-1300-R, WIR-1300-R
ECO-350-R, ECO-350-G, ECO-500-R, ECO-500-G, ECO-750-R
If one of the following infrared heat plates is connected to an additional
output, the foil sensor P-ISX-FF must be used, and must be activated
in the technician menu (see 8.2. Settings in the technician menu on
page 26):
IR-WP-100, IR-WP-175, IR-WP-390, IR-WP-510
IR-WPHL-100, IR-WPHL-175, IR-WPHL-390, IR-WPHL-510
User programs
The user programs enable favourite sauna settings to be saved and accessed
again.Thereare5presetuserprogramsavailablewhichcanbemodied
according to user requirements.
Post-drying program
After operation in combined mode, the post-drying program starts automatically
to prevent mould or rot from forming in the sauna cabin. This involves heating
the sauna cabin to 80 °C with the fan running for 30 minutes.
Overheat cut-out
The overheat cut-out is installed in the housing for the heater sensor. If a
defect causes the sauna heater to continue heating after reaching the pre-
ferredtemperature,theoverheatcut-outswitchesthesaunaheateroata
temperature of around 139 °C.
PRO C3
Same functional scope as the PRO C2, with the following additional features:
Regulation of combi heaters with a heating output of up to 10.5 kW and va-
porizer output of up to 3.5 kW in the temperature range spanning 30 °C to
110 °C and a humidity range spanning 5% to 100 %.
EN
Instructions for installation and use p. 11/47
Post-drying program
After operation in combined mode, the post-drying program starts automat-
ically to prevent mould or rot from forming in the sauna cabin. This involves
heating the sauna cabin to 80°C with the fan running.
The duration can be set from OFF - 60 minutes.
3.4. Sauna operating modes
The sauna control unit PRO B2 enables sauna mode. The sauna control unit Pro
C3 provides two operating modes, sauna mode and combi mode.
Sauna mode
Dry heat is provided in sauna mode. The temperature in the cabin is high (80 to
100°C). The humidity is low (no more than 10%).
Combi mode
In combined mode, the vaporizer operates along with the heater. The temper-
ature in the sauna cabin is lower (around 40 to 65 °C) than in sauna mode, but
the relative humidity is much higher, ranging from 35% to 70%. The maximum
humidity that can be set depends on the temperature of the sauna. The higher
the sauna temperature, the lower the maximum humidity level which can be set
(see characteristic curve on page 12).
3.5. Sensor operating modes
The sauna control unit can be operated with one or two sensors. A temperature
sensor (bench sensor, F2) or a humidity sensor (FTS2) can be used as the
second sensor.
Single sensor mode (F1)
Single-sensor mode must be activated in the technician menu (see 8.2. Settings
in the technician menu on page 26).
In single-sensor mode, the sauna control unit is operated with the heater sensor
with overheat cut-out (F1) only. This is included in the scope of delivery.
In single-sensor mode, the sauna control unit only displays the set temperature as
standard. The actual temperature is not displayed. If the sauna control unit is to
display the temperature above the heater (F1 sensor) as the actual temperature
in single-sensor mode, this must be activated during commissioning (see 8.2.
Settings in the technician menu on page 26).
Instructions for installation and use p. 12/47
The maximum humidity level which can be set in single-sensor mode is based on
the temperature above the heater and the humidity is timed. Only the set value
for the humidity level (in % of relative humidity) is displayed by the sauna control
unit. The actual humidity in the sauna cabin when the humidity is timed depends
onthesizeofthecabinandthevaporizeroutput,andmaydierfromthesetpoint.
Two-sensor mode with bench sensor (F2)
Two-sensor mode is the factory setting.
In two-sensor mode with bench sensor, a second temperature sensor (bench
sensor) is installed above the rear sauna bench. The sauna control unit displays
the temperature measured by the bench sensor as the actual temperature.
In two-sensor mode with bench sensor, the humidity is timed. Only the set value
for the humidity level (in % of relative humidity) is displayed by the sauna control
unit. The actual humidity in the sauna cabin when the humidity is timed depends
onthesizeofthecabinandthevaporizeroutput,andmaydierfromthesetpoint.
Two-sensor mode with humidity/temperature sensor (FTS2)
Two-sensor mode is the factory setting.
When a humidity/temperature sensor is used in two-sensor mode, the sauna
control unit displays the temperature which is measured by the humidity/tem-
perature sensor as the actual temperature.
In two-sensor mode with humidity/temperature sensor, the vaporizer is regulated
in accordance with the humidity level measured in the sauna cabin. The sauna
control unit displays the actual humidity (in % relative humidity) in the sauna cabin.
Temperature °C
Relative humidity %
EN 60335-2-53:2011; characteristic temperature / relative humidity for proper use.
EN
Installation instructions, only for experts p. 13/47
4. Installation
4.1. Installing the sauna control unit
Observe the following points when installing the sauna control unit:
The sauna control unit must be installed outside the sauna cabin or in accord-
ance with the recommendation issued by the sauna manufacturer.
The ambient temperature must be within a range spanning -10°C to +40°C.
The sensors may only be connected using the sensor cables supplied with
the unit, which are heat-resistant up to 150°C.
ATTENTION!
Damage to the unit
The sauna control unit is resistant to splashing water, but direct contact with
water could still damage it.
Install the sauna control unit in a dry place at which a maximum humidity of
95% is not exceeded.
The sensor leads may be extended under the following conditions:
A silicon cable resistant to temperatures up to 150 °C is used.
The minimum cross-sectional of the cable is 0.5 mm2.
The heater sensor cables may NOT be longer than 10 m.
ATTENTION!
Interference can impair signal transmission
Route all sensor cables separately from other mains cables and control cables.
Protect cables with only one layer of insulation by using a conduit (double
insulation).
Installation instructions, only for experts p. 14/47
Fig.1 Position of the attachment device and the installation holes
(dimensions in mm)
C
To install the sauna control unit, perform the following steps:
1. Screw two cross-head screws (16 mm) into the wall of the sauna at a height
of approx. 1.70 m and leaving a protruding length of 7 mm. The two screws
must be placed at a distance of 145 mm from each other (see Fig.1).
2. Press the clip locks C in lightly using a screwdriver and remove the cover
from the housing (see Fig.2).
3. Fasten the sauna control unit onto the cross-head screws using the attach-
ment device A as an aid (see Fig.1).
4. Screw two cross-head screws (16 mm) into the lower fastening holes B
(see Fig.1).
82
80
34
175
145
34
43
40
A
B
Fig.2 Removing the cover from the housing
EN
Installation instructions, only for experts p. 15/47
4.2. Installing the heater sensor F1 with overheat cut-out
Note the following points when installing the heater sensor:
The heater sensor must be installed on the rear of the heater, above the
middle of the sauna heater. A distance of about 15 cm from the ceiling of the
cabin must be maintained.
Theheatersensormustbeinstalledinsuchawaythatitisnotaectedby
inowingair.
To install the heater sensor, perform the following steps (see Fig.3):
1. Route the two 2-pole heater sensor cables in the wall of the sauna cabin
totheinstallationlocationoftheheatersensorandaxtheheatersensor
cables using cable clips.
2. Pull the two half-shells 1 of the heater sensor apart.
3. Connect the four connections for the heater sensor cable 5 in accordance
with the Fig.3.
4. Place the connection panel 2 crossways (as shown in Fig.3) in the heater
sensor half-shells.
5. Place the two half-shells together, screw them together using two cross-
head screws 3 (9 mm) and check whether the heater sensor has been
securely closed.
6. Install the heater sensor on the rear of the heater using the two wood screws
6 supplied (16 mm).
1 Heater sensor half-shells
2 Connection panel
3 Cross-head screws (9 mm)
4 Heater sensor
5 Heater sensor leads
6 Wood screws (16 mm)
Fig.3 Installing the
heater sensor
Red
White
White
Red
Installation instructions, only for experts p. 16/47
4.3. Installing bench sensor F2 (optional)
The bench sensor must be installed on the wall of the cabin above the rear bench
seat. A distance of about 15 cm from the ceiling of the cabin must be maintained.
To install the bench sensor, carry out the following steps:
1. Route the 2-pole bench sensor lead in the wall of the sauna cabin to the
mountinglocationofthebenchsensorandaxthebenchsensorleads
using cable clips.
2. Pull the two half-shells of the bench sensor apart.
3. Connect the two connectors for the bench sensor lead to the two middle
terminals on the connection panel.
4. Place the connection panel crossways in the bench sensor half-shells.
5. Place the two half-shells together and screw them together using the two
cross-head screws (9 mm).
6. Check whether the bench sensor has been securely closed.
7. Install the bench sensor on the wall of the sauna cabin using the two sup-
plied wood screws (16 mm). Maintain a clearance of 15 cm from the roof
of the sauna cabin.
4.4. Installing humidity/temperature sensor FTS2 (optional,
PRO C3 only)
The humidity/temperature sensor must be installed on the wall of the cabin above
the rear bench seat. A distance of approx. 15 cm from the ceiling of the cabin
must be maintained.
To install the humidity and temperature sensor, perform the following steps:
1. Route the 5-pole sensor cable in the wall of the sauna cabin to the mount-
ingpositionofthehumidity/temperaturesensorandaxthesensorleads
using cable clips.
2. Install the humidity/temperature sensor to the wall of the sauna cabin using
the two supplied wood screws (16 mm). Maintain a clearance of 15 cm to
the roof of the sauna cabin.
4.5. Installing the foil sensor (optional)
If an infrared heat plate is to be connected to an additional output, the P-ISX-FF
foil sensor must be used.
When installing the foil sensor, observe the operating instructions for the
infrared heating plates.
Use of a foil sensor must be activated in the technician menu (see 8.2. Settings
in the technician menu on page 26).
EN
Installation instructions, only for experts p. 17/47
5. Electrical connection
ATTENTION!
Damage to the unit
The sauna control unit may only be used for operating and controlling 3 heating
circuits with a maximum heating capacity of 3.5 kW per heating circuit. The
maximum vaporizer output (PRO C3 only) is 3.5 kW. The maximum additional
output totals 3.5 kW.
1
2
4
3
5
6
b
7
8
9
a
c
d
e
f
1 Low-voltage connection area
2 Terminalstripsforsafetyshut-o,remote
start, status output and sensor cables
3 Function selection switch
4 Cable gland for F2, FTS2 and foil sensor
5 Cable gland for F1 sensor and status output
6 Cableglandforsafetyshut-oandremote
start
7 Cable gland for vaporizer wire and addi-
tional output
8 Cable gland for heater cable
9 Cable gland for power supply cable
a Cable gland for power booster
b Cable gland for light and fan
c Terminal strip for heater and vaporizer wires,
power supply cable and additional device
d Terminal strip for lights and fan
e Terminal strip for power booster
f Connection area for 230 V/400 V
g Earthing bar
h RJ45 socket for RS-485 and MySentio WiFi
g
h
Installation instructions, only for experts p. 18/47
Please observe that in the event of a guarantee claim, a copy of the bill
from the electrician performing the work must be presented.
Observe the following points when connecting the power to the sauna control unit:
Installation may only be performed by a qualified electrician or similarly
qualiedperson.
Work on the sauna control unit may only be performed when the power has
been disconnected.
● Theremustbeaxedconnectionfortheelectricalpowersupply.
A fully disconnecting all-pole isolating device compliant with overvoltage
categoryIIImustbettedonsite.
Observe the connection diagram (Fig.4) on page 23.
5.1. Connecting the power supply cable, heater and vaporizer
1. Feed the power supply, heater and vaporizer cables (PRO C3 only) through
the cable glands 9, 8, 7 into the connection area for 230 V/400 V f.
2. Connect the cables to the terminal strip c in accordance with the connection
diagram. Follow the operating instructions for each device.
3. If the vaporizer does not feature an automatic low-water indicator, then
perform the following step as well:
Use the wire jumper enclosed to connect terminal “V1” to terminal “Wm”.
5.2. Connecting the light
1. Feed the light cable through the cable gland b into the connection area
for 230 V/400 V f.
2. Connect the light cable to the terminal strip d in accordance with the con-
nection diagram. Observe the operating instructions for the respective device.
5.3. Connecting the fan (optional)
1. Feed the fan cable through the cable gland b into the connection area for
230 V/400 V f.
2. Connect the fan cable to the terminal strip d in accordance with the connec-
tion diagram. Observe the operating instructions for the respective device.
EN
Installation instructions, only for experts p. 19/47
5.4. Connecting the additional output (optional)
The additional output can, for example, be used for an infrared heater or infrared
heating plates.
1. Feed the connection cable for the additional device through the cable gland
7 into the connection area for 230 V/400 V f.
2. Connect the cables to the terminal strip c in accordance with the connec-
tion diagram. Observe the operating instructions and safety information for
the respective device.
WARNING!
Risk of re
The additional output has no overheat cut-out. For this reason, only
intrinsically safe devices should be operated using the additional output.
If infrared heaters are connected to the additional output, they must
have an overheat cut-out.
If infrared heating plates are connected to the additional output, the foil
sensor P-ISX-FF must be used, and must be activated in the technician
menu (see 8.2. Settings in the technician menu on page 26).
5.5. Connecting the power booster (optional)
1. Feed the cable for the power booster through the cable gland a into the
connection area for 230 V/400 V f.
2. Connect the cable for the power booster to the terminal strip e in
accordance with the connection diagram. To do so, use terminal
ST1” for the safety circuit, and terminal “ST2” for the control circuit.
Follow the operating instructions for each device.
5.6. Connecting the heater sensor F1
1. Feed the wires for the heater sensor through the cable gland 5 into the
low-voltage connection area 1.
2. Connect the red wires for the heater sensor to the terminals labelled “STB
in terminal strip 2.
3. Connect the white wires for the heater sensor to the terminals labelled “F1
in terminal strip 2.
Installation instructions, only for experts p. 20/47
5.7. Installing bench sensor F2 (optional)
1. Feed the wires for the bench sensor through the cable gland 4 into the
low-voltage connection area 1.
2. Connect the wires for the bench sensor to the terminals labelled “F2” in
terminal strip 2.
5.8. Connecting the humidity/temperature sensor FTS2 (optional,
PRO C3 only)
1. Feed the wires for the sensor through the cable gland 4 into the low-voltage
connection area 1.
2. Connect the wires for the temperature sensor to the terminals labelled “F2
in terminal strip 2.
a. the black wire to the right terminal.
b. the brown wire to the left terminal.
3. Connect the wires for the humidity sensor to the terminals labelled “+ S -
in terminal strip 2.
c. the green wire to terminal “+”.
d. the orange wire to terminal “S”.
e. the red wire to terminal “-”.
5.9. Connecting the foil sensor (optional)
1. Feed the wires for the sensor through the cable gland 4 into the low-voltage
connection area 1.
2. Connect the sensor cables for the sensor to the terminals labelled “FF” in
terminal strip 2.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320
  • Page 321 321
  • Page 322 322
  • Page 323 323
  • Page 324 324
  • Page 325 325
  • Page 326 326
  • Page 327 327
  • Page 328 328
  • Page 329 329
  • Page 330 330
  • Page 331 331
  • Page 332 332

Sentiotec Pro C3 Manuale utente

Tipo
Manuale utente
Questo manuale è adatto anche per