quiko QK-CE220CTD Manuale utente

Tipo
Manuale utente
QK-CE220CTD (1.2)
EN Installation and operation manual
Control unit
CAP
MOT
B
MOT
B
COM
COM
MOT
A
MOT
A
CAP
EV1
AC2
EV2
LAMP
AC2
SEM
RED
SEM
GRN
PRESS
1
COM
PRESS
2
AN.
IN
UPS
AUX
COM
SHIELD
ANT
START
PDM
OPEN
COM
CLOSE
FTC
STOP
COM
FCA
FCC
INPUTS
INPUTS
OUTPUTS HV OUTPUTS HV
OUT4
AUX
OUT5
2ndRX
24VAC1
24VAC2
OUT LED
24VAC2
OUT BUZZER
BRK +
BRK -
OUTPUTS LV
E
N
G
L
I
S
H
V05/2017
1,2,3,4
- 2 -
J4
OUT4
AUX
OUT5
2ndRX
24VAC1
CAP
MOT B
MOT B
COM
COM
MOT A
MOT A
CAP
PRES 1
COM
PRES 2
AN. IN
UPS
AUX
COM
SHIELD
ANT
24VAC2
OUT LED
24VAC2
OUT BUZZER
START
PDM
OPEN
COM
CLOSE
FTC
STOP
COM
FCA
FCC
BRK +
BRK -
OUTPUTS LV INPUTS INPUTS
J1 J3A J5A J5B
OUTPUTS HV
230V ~
50-60Hz
P
NCNCNO
NC NC
NO
NO NO
BZ2
BZ1
LED1 LED2
M1
BOLLARD
1
BOLLARD
2
M2
- +
EV1
AC2
EV2
LAMP
AC2
SEM RED
SEM GRN
J3B OUTPUTS HV
EV1.1 EV1.2
EV2.1 EV2.2
P
NO NO
P P
- +
+ - + -
Only with FX
emergency FX
(not supplied)
emergency FX
(not supplied)
With
BATTERY
UNIT
Without
BATTERY
UNIT
NO
NO
QK-CT3301200LK12
max 2 bollards
Per/For
CONNECTION SCHEME FOR K12 BOLLARDS ONLY. FOR ALL OTHER MODELS PLEASE REFER TO PREVIOUS PAGE
8QK-CT3301200LK12
Electrovalve (230Vac RAC), for FX bollards equipped only
Cover lights 12Vac (QK-CT3301200LK12 only)
Self-powered output. 12Vac, 800mA max
Cover buzzer 12Vac (QK-CT3301200LK12 only)
Self-powered output. 12Vac, 100mA max
1
PRES 2
FX pressure switch input (see parameter - level 3 and parameter- level 2).
(For FX equipped bollards only).
AUXILIARY INPUT AUX
For bollards with FX device. Is active when emergency FX command is active (see parameter - level 3)
3 wire N.O. closing limit switch imput (set parameter  - level 3and parameter  - level 2).
When activated the opening travel ends (QK-CT3301200LK12).
3 wire N.O. opening limit switch imput (set parameter  - level 3). When activated the opening travel
ends (QK-CT3301200LK12).
FX present.
For QK-CT3301200LK12
: FX pressure switch failure
: FCC sensor failure or manual forcing attempt
FX pressure switch
polarity

PRESSURE SWITCH
FX PRES2
NOT PRESENT
Connect all YELLOW cables of the LED
lamps in parallel
Connect the GREEN cables of the limit
switch in parallel.
Connect the VIOLET cables of the pressu-
re switch in parallel
Connect the GREEN/BROWN cables of
the burglar device contact in parallel, if
envisaged
NOT PRESENT
Connect the WHITE cables of the electro-
valve element in parallel
Connect the PINK cables of the electro-
valve element in parallel , if FX present
Connect the GREEN cables of the FX pressure switch in parallel, if present
TX
TX
TX
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

quiko QK-CE220CTD Manuale utente

Tipo
Manuale utente

in altre lingue